NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Similar documents
Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Protector Selection Guide

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Circuit Protectors CP31F, 32F, 33F

Selection Guide. Control Circuit and Load Protection

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

209 Series. Magnetic Circuit Protectors

G-Series. Circuit Breaker.

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

209/219/229/249/279 Series Magnetic Circuit Protectors

HEAVY DUTY POWER RELAYS FEATURES

PD-Series Ground Fault Circuit Protection

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

1492-CB 1492-GH 1492-GS

Magnetic and Hydraulic-Magnetic Circuit Breaker

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Magnetic and Hydraulic-Magnetic Circuit Breaker

ø8 A8 Series Miniature Control Units

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

NC1V. Circuit Breakers

Essential equipment for all your requirements

Catalog Issued 3-03 (PDF Rev )

PB-Series. GFCI/ELCI & Panel Seal

HS5D Miniature Interlock Switches

AR circuit breaker - Hydraulic magnetic,

Magnetic Overcurrent Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

PS6R 480W Switching Power Supply

SAR & SAS Circuit Protectors

ER circuit breaker - Hydraulic magnetic,

22AF 40AF AF 150AF 225AF 400AF 800AF

6mm and 14mm Slim Interface Relay

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Relays & Sockets. RV8 Series 6mm Interface Relays. (when using combination of RV relay and SV socket) RV8H Electromechanical Part Numbers

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

QF(19) - Series Miniature Circuit Breakers

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Miniature Switches & Pilot Devices

Model Number Structure

DD Frame - Series Circuit Breakers

Typical UL1077 Application

F-Series. Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

F-Series. Circuit Breaker

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

RY/RM Series General Purpose Miniature Relays

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Solenoid Locking Safety Switches

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Industrial Relay KML(1C, 2C)

FR circuit breaker - hydraulic magnetic,

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Control Circuit Protection

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Solenoid Locking Safety Switches

Thermal Overcurrent Circuit Breaker 3120-F...

Relays & Sockets. RQ Series PCB Relays

Electronic Circuit Breaker ESS20-0..

ø10 A1 Series Miniature Control Units

CI-TI Contactors and motor starters Types CI 61 - CI 98

MAGNETIC MOTOR STARTERS

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Table of Contents. HCC Contactor Nomenclature

Micro Contactor MA Series

1 Form A 5A small size power relay for interface

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

CX-Series. Circuit Breaker

Miniature Circuit-Breakers (MCBs)

Technical Information

Control Relays Overview

ø12 A2 Series Miniature Control Units

Thermal Overcurrent Circuit Breaker 3120-F...

AF series contactors (9 2650)

GT5P Series ON Delay Timers

Ktec Contactors and thermal overloads

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

QF(13) - Series Miniature Circuit Breakers

Industrial Contactors CTX 3 3P 185A - 800A

PDR circuit breaker - Ground fault Datasheet

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Control Circuit of a UL508A Panel. Typical UL1077 Application

6mm Interface Relays RV8 Series

Circuit Breakers Series AM/S

Transcription:

NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that can be widely employed for semiconductors, relay circuits, heater circuits, transformers, and solenoids. Key features of the NRBM series include: Excellent overload and short circuit protection Small size and high efficiency Life expectancy of over 0,000 operations UL077 recognized Supplementary Protectors VDE Certified to EN60934 File No. E68029 License #3434 General Specifications Protection Method Electromagnetic tripping Internal Circuit Series current trip Number of Poles, 2, 3 Rated Voltage 250V AC, 50/60Hz, 65V DC Rated Tripping Currents Current trip: A, 2A, 3A, 5A, 7.5A, 0A, 5A, 20A, 25A, 30A, 40A, 50A Rated Interrupting Capacity 250V AC, 50/60Hz,,000A 65V DC,,000A Auxiliary Contacts / Alarm Contact SPDT microswitch 250V AC, 5A (resistive load) 50V DC, A (resistive load) Reference Temperature 25 C Ambient Operating Temperature 40 to +85 C (avoid freezing) Insulation Resistance 00MΩ (measured with 500V megger) Dielectric Strength Between main circuit terminals: 2,000V AC, minute Between main circuit and auxiliary contact: 2,000V AC, minute Vibration Resistance 00N (approximately 0G), 0 to 55Hz Shock Resistance,000N (approximately 00G) Life Expectancy 0,000 operations minimum (at 6 operations per minute) Terminal Style Main terminal: M5 stud Auxiliary contact/ alarm contact: Quick-connect tab 0.0 terminal -pole/00g Weight 2-pole/200g 3-pole/300g Not suitable for branch circuit protection. Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Part Numbering Guide Switches & Pilot Lights Display Lights Relays & Sockets NRBM series part numbers are composed of 6 part number codes. When ordering an NRBM series part, select one code from each category. Example: NRBM F-30A-AA NRBM F 30A AA j Poles k Internal Circuit l Auxiliary and Alarm Contacts m Inertia Delay n Rated Current o Time Delay Curve Part Number Codes: NRA Series Description Part Number Code Remarks -pole j No. of Poles 2-pole 2 All multiple pole circuit breakers are simultaneous throw/simultaneous break. All levers are mechanically interlocked. 3-pole 3 k Internal Circuit Series current trip Without 00 l Auxiliary and Alarm Contacts With auxiliary contact Auxiliary contacts change state with lever and/or overload condition With alarm contact 2 Alarm contacts change state only with overload condition m Inertia Delay Without inertia delay Blank With inertia delay F n Rated Current Rated current (current trip) A, 2A, 3A, 5A, 7.5A, 0A, 5A, 20A, 25A, 30A, 40A, 50A o Time Delay Curve AC curves AA, BA,MA DC curves AD, MD See page 897 for delay curves.. For NRBM series time delay curves, see page 897. 2. For NRBM series dimensions, see page 899. 3. Not suitable for branch circuit protection. 4. UL recognized, applicable standard: UL077, Supplementary Protectors. Terminal Blocks Timers Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Information About Time Delay Curve Descriptions Time Delay Curve AD, AA BA MD, MA With Inertia Delay (F) Inertia Delay Descriptions Common curves used in molded-case circuit breakers. NRBM Application Response to overcurrent is quite fast. Suited for protection of semiconductor circuits with very little overload tolerance. If overcurrents are expected to fl ow, fuses may be required according to the circuit characteristics. Suited for motor loads that draw high inrush currents lasting a considerable length of time. Designed not to trip on 20 times the rated current (peak value) for a duration of 8ms. Suited for transformer and lamp loads that draw steep inrush currents. Circuit breakers equipped with inertia delay do not respond to high inrush currents such as those produced by transformer, lamp, or motor loads, but perform specifi ed interruption on rated overcurrents. Inertia delay is available with time delay curves AD, MD, AA, BA, and MA. Specify inertia delay by inserting an F in the part number as shown in Part Number Guide on previous page. Multi-Pole Multi-pole types such as 2- or 3-pole should be assembled by IDEC. Notes 6,000 4,000 2,000 0,000 Because of their characteristics, -pole breakers cannot be combined to provide multi-pole units. All multi-pole units are simultaneous break/simultaneous make, with levers mechanically interlocked. Auxiliary and Alarm Contacts Percent of Rated Current 8,000 6,000 4,000 2,000 Pulse Width Pulse Peak Current (duration) 2 3 4 5 6 7 8 9 0 Pulse Width (ms). Percent of Rated Current = Pulse Peak Current x 00% Protector Rated Current 2. Based on sinusoidal or parabolic pulse profile. Multi-pole units with auxiliary contacts will have one set of auxiliary contacts on the right-most breaker. Multi-pole units with alarm contacts will have one set of alarm contacts on the left-most breaker. Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Internal Circuits and Terminal Arrangements Switches & Pilot Lights Series Current Trip LINE Series Current Trip with Auxiliary Contacts LINE NC NO Series Current Trip with Alarm Contacts LINE NO NC Display Lights C C LOAD LOAD LOAD Relays & Sockets Time Delay Curves (numerical equivalent) Overcurrent Time Delay Characteristics in Seconds Percent of Rated Current Curve 00% 25% 50% 200% 400% 600% 800% 000% Timers AC (50/60Hz) DC Terminal Blocks AA No trip 5 20 8 45 3 5 0.48 2.5 0.06 0.8 0.007 0.3 0.005 0.04 BA No trip 0.75 0 0.45 3.5 0.22.3 0.045 0.22 0.02 0.2 0.005 0.06 0.004 0.03 MA No trip 70 900 30 260 0 70.8 0.5 4 0.009. 0.006 0.2 AD No trip 0 30 6 55 2.6 20 0.5 3.5 0.4.4 0.008 0.7 0.005 0.35 MD No trip 35 400 20 80 8 60.6 0 0.6 4.5 0.0 2 0.007 0.5. All values above are in seconds. 2. Data in this table is equivalent to information presented in the time delay curves shown on page 897. Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

AC Time Delay Curves 000 00 0 0. 0.0 000 00 0 0. 0.0 Curve AA 00 50 200 300 400 500 600 700 800 900 000 25 000 00 0 0. 0.0 00 50 200 300 400 500 600 700 800 900 000 25 000 00 0 0. 0.0 00 50 200 300 400 500 600 700 800 900 000 25 Curve BA 00 50 200 300 400 500 600 700 800 900 000 25 Curve MA Curve AD DC Time Delay Curves 000 00 0 0. 0.0 Curve MD 00 50 200 300 400 500 600 700 800 900 000 25 Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Resistance and Impedance Characteristics Switches & Pilot Lights Coil Data Rated Current DC Resistance Curves AD, MD AC Impedance (50/60Hz) Curves AA, BA, MA A Ω.Ω 2A 0.227Ω 0.245Ω 3A 0.09Ω 0.Ω Coil Resistance at 25ºC Rated Current (A) 00 0 0. Correction curve of resistance between terminals Curves AD and MD Display Lights 5A 0.035Ω 0.039Ω 7.5A 0.05Ω 0.08Ω 0A 0.0088Ω 0.024Ω 5A 0.005Ω 0.0065Ω 20A 0.003Ω 0.0047Ω 25A 0.0023Ω 0.0032Ω 30A 0.009Ω 0.003Ω 40A 0.008Ω 0.002Ω 50A 0.004Ω 0.006Ω 0.0 0.000 0.00 0.0 Rated Current (A) 00 0 0. 0. 0 00 Resistance (Ω) Correction curve of impedance between terminals Curves AA, BA, and MA Relays & Sockets Timers Tolerance ±25% (up to 20A), ±50% (25A and over). Voltage Drop Due to Resistance or Impedance The internal resistance or impedance of a circuit breaker tends to be larger for a smaller rated current. Therefore, when circuit breakers of a small rated current are used, voltage drop should be taken into consideration. Internal resistance also varies with time delay curves, even at the same rated current. This should also be considered during installation. Time Delay Curve and Ambient Temperature Since NRBM series circuit breakers employ an electromagnetic tripping system, the rated current (trip current) is not affected by the ambient temperature, but the time delay varies with the oil viscosity in the tube. Lower oil viscosity at higher temperatures results in shorter delay; whereas at lower temperatures, the delay will be prolonged. The time delay curves, shown starting on page 897, are at 25 C. Time delay curves can be corrected. 0.0 0.00 0.0 Temperature Correction Curves Terminal Blocks Change of time delay (%) 0. 0 00 Impedance (Ω) Ambient Temperature (ºC) Curves AA and AD, BA,MA and BD At the minimum operating current (25% current) Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Dimensions: NRBM 63.0 52.3 35.0 -pole 2-pole 3-pole Drawings are not to scale. 2-M3 screw 9. 9. 9. 38.2 57.3 60º 3.5 20.5 2-M3 screws 0.0 Main terminal: M5 screw 52.3 -pole 2-pole 3-pole 47.5 6.0 63.5 Recommended nut tightening torque: 2.5 N m 49.2 Tab terminal #0 (2.8W 0.5t) Panel Cut-Outs 9.8 9. 9. 26.5 9.6 38.7 57.8 ø4 Mounting hole 20.95 35.5 Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com