Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Similar documents
Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

and other modular devices for low voltage installation

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Innovation That Leads the Change

Electronic circuit breaker EBU10-T

Jtec 10kA Miniature Circuit Breaker

The effective choice The benefits of a product with the highest quality standards

Manual Motor Starters. Meta-MEC

DRX 100 B/N/H Circuit breaker (not adjustable)

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DRX 250 B/N/H Circuit breaker (not adjustable)

Miniature Circuit Breaker

DRX 125 Circuit breaker (not adjustable)

ABB STOTZ-KONTAKT GmbH

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Miniature Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Magnetic only

3 - Protection components Motor circuit-breakers

MINIATURE CIRCUIT BREAKER

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

max pole for t=15 ms

cor Long Run Experience

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Jtec 489 UL489 Branch Circuit Breaker

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

ACW Molded-Case Circuit Breaker UL 489 Listed

COMPLETE SOLUTIONS FOR POWER PROTECTION

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

DPX earth leakage DPX 3 -I earth leakage

Thermal-magnetic Miniature Circuit Breaker 4230-T...

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

DSE201 Compact design with enhanced protection

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

Technical catalogue. System pro M. Residual current devices 2CSC420001D0201

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

New DX 3 High rating & breaking capacity

Data Sheet Manual Motor Starter Ex9S32 Series

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

UMBW-UL489 and UL1077 Listed

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

World Super Series WSS The extensive breaker series from Mitsubishi Electric

Control Circuit Protection

DPX 1600 Electronic release

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

CHINT. NM7 Moulded Case Circuit Breaker

Data Sheet Manual Motor Starter Ex9S32 Series

DPX moulded case circuit breakers

R.C.B.O. SP / 1 module

QF(13) - Series Miniature Circuit Breakers

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Thermal-Magnetic Circuit Breaker M1-...

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

Low Voltage A GE Power Controls Company. General catalogue

DPX Electronic + earth leakage

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Protection components

Residual current circuit breakers with conditional shortcircuit

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

D509E. Manual Motor - Starters

QF(19) - Series Miniature Circuit Breakers

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

3VU13, 3VU16 Circuit-Breakers

SH 200 T SH 200 L SH 200 Mechanical Toggle

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Series KTU7 UL489 Molded Case Circuit Breakers

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

Low breaking capacity moulded case circuit breakers

MS General Information Extended Product Type: MS

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

NDM1 Series MCB Edition

Protection Equipment

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Thermal magnetic and trip-free switches

Phase + Neutral, neutral on left side

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

Miniature Circuit-Breakers (MCBs)

QUALITY ASSURANCE & DOCUMENTATION

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Btdin RCBO 6000A up to 63A (2P)

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

Transcription:

Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable earthleakage protection (4) High currentlimiting performance (5) Compliance with IP2X protection rating () All models are compatible with reverse connection (7) DC circuitcompatible model (BHD) added to product lineup Product up Model type No of poles (P) Rating Instantaneous tripping Voltage (V) ShortCircuit capacity (ka) Compliance standard BHD 1, 2, 3, 4(3+N) 1+N 0.53A 0.540A TYPE B, C, D TYPE B, C 230AC IEC08981 MCB BHD BHD (For DC) 1, 2, 3, 4(3+N) 1 2 0.53A 0.53A TYPE B, C, D TYPE B, C 125DC 250DC IEC08981 IEC08982 BHDN 1+N 20A TYPE C 230AC 4.5 IEC08981 RCCB 2(1+N), 4(3+N) 25, 40, 3A IEC08 RCBO 1+N 40A TYPE C 230AC 4.5 IEC09 Isolating Switch KBD 1, 2, 3, 4(3+N) 32, 3, 80A IEC09473 Explanation of Markings (Example Model : BHD) Model type Rated voltage Standard Instantaneous tripping model type and Rated current Shortcircuit capacity Wiring diagram Technical Specifications Ambient temperature range Frequency ~ +40 50/0Hz 3

MINIATURE CIRCUIT BREAKERS,RESIDUAL CURRENT CIRCUIT BREAKERS & ISOLATING SWITCHES DIN Series Points to Note Installation Connection 1 2 3 4 Standard IEC35mm rail installation is possible. Fix by attaching a slip stopper. Fig1 1. Installation 2. Removal Opening, Closing and Tripping Operations At the time of wire connection, fasten the terminal screws with the torque stated in the table below. Fastening torque Screw diameter M5 M4 M3.5 Fastening torque Nm 1.72.5 1.01.5 0.81.0 Model type BHD, BHD,, KBD SHTA40005DLS, SHTD04805DLS BHDN, AL05DLS, 05DLS, AL05DLS 205DLS Move the handle up/down to turn power On/Off. Tripping operation refers to automatic opening (breaking) of circuits. Earthleakage Test Earthleakage test steps: (1) Move the handle to the On position under rated voltage. (4) The handle will move to the Off position. (2) Push the yellow test button. (5) The earthleakage indication changes from white to red. (3) At this time, the RCCB or RCBO must be tripped within the specified time. 5 Withstand Voltage Test (1) (2) Withstand voltage test: The voltage applied to the main circuit during the withstand voltage test is 2,000VAC (effective for 1min). Do not conduct a withstand voltage tests using voltages exceeding 2,000VAC. Measurement of insulation resistance and withstand voltage test Please note the following restrictions ( and below) that apply when using earthleakage circuit breakers. Measuring insulation resistance: Do not use a 00V insulation resistance tester. Please use a 500V insulation resistance tester. The marks in the table are based on minimum insulation resistance values. Testing withstand voltage: The X marks in the table below indicate that the test voltage is not to be applied to that model. (If a test voltage is accidently applied to one of these models, do not reuse the product regardless of whether or not they were tripped.) Test Measuring position Handle position Between main circuit live part and ground 2P On line side Between right pole (terminal symbol ) and N pole Between 4P Between poles other than above different 2P poles On load side Between right pole (terminal symbol ) and N pole 4P Between poles other than above Between terminals on line side and load side Insulation resistance measurement ON OFF Withstand voltage test ON OFF Installation of Accessories (, AL, SHT) (1) Installation (2) Removal Off Hook Insert Click 4

DIN Series Specifications RCCB RCBO Image Image No. of poles [P] 2(1+N) 1 1 3 4(3+N) Rated current [A] 25, 40, 3 Rated voltage [VAC] 230 230/400 Rated current sensitivity I n [ma] 30, 300 Max. operating time at 5I n [s] 0.04 AC Rated conditional shortcircuit current [ka] Dimensions [mm] a 3 72 b 85 c ca 70 Mass [kg] 0.2 0.35 Rated making and breaking capacity Im [A] 500(In 25,40A), 30(In3A) Rated conditional shortcircuit current Inc [ka] Rated residual making and breaking capacity I m [A] 500(In 25,40A), 30(In3A) Rated conditional residual shortcircuit current I c [ka] Number of operating cycles Without current 8,000 With current 8,000 of overcurrent release Mounting IEC35mm rail Applicable wire size 1 to 25mm 2 Weight [kg] 0.2 0.35 Terminal connection Based on standard CE marking CCC a b ca c IEC081 EN081 : Selfdeclaration GB191 No. of poles [P] Rated current [A] 2(1+N) 1,, 1, 20, 25, 32, 40 Rated voltage [VAC] 230 Rated current sensitivity I n [ma] 30, 0, 300 Max. operating time at 5I n [s] 0.04 AC Breaking capacity [ka] sym. (IEC 09) 4.5 Tripping characteristics Dimensions [mm] C 2 a 3 b 88 c ca 70 Mass [kg] 0.19 Automatic tripping device Number of operating cycles Thermal, magnetic Without current 20,000 With current of overcurrent release Mounting 20,000 (In,,1,20A) 15,000 (In 25A),000 (In 32,40A) Thermalmagnetic IEC35mm rail Applicable wire size 1 to 1mm 2 Weight [kg] 0.19 Terminal connection Based on standard CE marking CCC IEC091 EN091 : Selfdeclaration GB19 1: N pole is a switched neutral pole (without overcurrent release device). 2: C: (5 In <, In) 3: For use to three phase 4wire type. When using, it be sure to connect the neutral wire to the neutral phase. Not available for use to three phase 3wire type. a b ca c Isolating switch KBD Image No. of poles [P] 1 2 3 4(3+N) Utilization category Rated current [A] AC22A class 32, 3 Rated voltage [VAC] 230 400 Short time withstand current [A] Shortcircuit making capacity [A] Dimensions [mm] 20 5 In, 1s 20 5 In a 18 3 54 72 b 87 c ca 70 Mass [kg] 0.09 0.18 0.27 0.3 Optional accessories Insulating barrier 1 pc. 2 pcs. 3 pcs. Number of operating cycles Mounting Without current 20,000 With current 3,000 IEC35mm rail Applicable wire size 1 to 25mm 2 Weight [kg] 0.1 0.2 0.3 0.4 Terminal connection Based on standard CE marking CCC a b ca c IEC09473 EN09473 : Selfdeclaration GB14048.3

Accessories Functions of Accessories Internal accessory Function AL Alarm switch Electrically indicates the trip status of the circuit breaker. Auxiliary switch SHT Shunt trip Electrically indicates the On/Off status of the circuit breaker. Electrically trips the circuit breaker from a remote location. Permissible working voltages are 70 to 1% of the AC rated voltage or 70 to 125% of the DC rated voltage. Equipping of Accessories Accessory Model name BHD BHD BHDN,, KBD, AL SHT : Accessory equipped : Accessory not equipped Specifications AL AL+ + AL05DLS 05DLS AL05DLS 205DLS Contact Function Configuration 1C 1C 2C 2C Contact capacity 400VAC, 2A 230VAC, 5A 130VDC, 0.4A 48VDC, 1.5A AL AL Connection Busbar terminal Compliance standard IEC094751 GB14048.5 SHTA40005DLS SHT SHTD04805DLS Cutoff switch Equipped Voltage 1400VAC 2448VDC Input power requirement 1VAC 0VA 24VDC 75VA 230VAC 250VA 48VDC 300VA 400VAC 750VA Operating time [ms] <20 Connection terminal Compliance standard IEC09472 GB14048.2 * Secure a sufficient input power supply so that the voltage will not drop below the permissible lower working voltage (70% of the lowest rated voltage). * The operating time denotes the time from when the rated voltage is applied to SHT until the time the main contact of the breaker starts to open. 7

DIN Series Accessories Combinations of Accessories AL 2 AL Accessory connection combinations SHT +SHT AL+SHT 2+SHT AL+SHT Breaker AL AL AL+ + SHT Outer Dimensions AL05DLS 05DLS AL05DLS 205DLS SHTA40005DLS SHTD04805DLS AL05DLS terminal 92 92 95 87.5.5 47.5.5 M3.5 screw M3.5 screw 9 9 9 M3.5 screw 18 M5 screw Connection of and Side AL05DLS 05DLS AL05DLS 205DLS 12 14 11 11 c 12 b 14 a 12 14 11 11 c 12 b 14 a 95 ALc 9 98 95 AL 9 ALb 14 12 11 98 ALa 11 c 12 b 14 a 9 98 95 AL 95 ALc 9 ALb 98 ALa 24 22 21 21 c 22 b 24 a 8

Characteristics and Dimensions Residual Current Circuit Breakers (RCCB) No. of poles [P] Rated operational voltage Ue [AC V] Rated current In [A] 2(1+N) 1 4(3+N) 1 2 230 230/400 25, 40, 3 Rated current sensitivity I n [ma] 30, 300 Max. operating time at 5I n [s] 0.04 AC Residual operation Dependent on line voltage Rated making and breaking capacity Im [A] Rated conditional shortcircuit current Inc [ka] 500(In 25,40A) 30(In3A) Rated residual making and breaking capacity I m [A] 500(In 25,40A) 30(In3A) Rated conditional residual shortcircuit current I c [ka] 1: N pole is a switched neutral pole (without overcurrent release device). 2: For use to three phase 4wire type. When using, it be sure to connect the neutral wire to the neutral phase. Not available for use to three phase 3wire type. noperating Characteristics 4h 2h 1h 30min Operating time 2min 1min 30s s 5s 2s 1s Rated current sensitivity 4min Rated nonoperating current min 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s 25 50 0 500 Groundfault current (% of rated current sensitivity) nouter Dimensions Test button Residual indicator 18 3 18 54 72 85 42.5 M5 screw 70 maximum terminal 2P 11 4P

DIN Series Characteristics and Dimensions Residual Current Circuit Breakers with Overcurrent Protection (RCBO) 2(1+N) 1 No. of poles [P] Rated operational voltage Ue [VAC] 230 Rated current In [A],, 1, 20, 25, 32, 40 Instantaneous tripping C Rated current sensitivity I n [ma] 30, 0, 300 Max. operating time at 5I n [s] 0.04 AC Residual operation Dependent on line voltage Rated IEC091 shortcircuit GB19.1 capacity [ka] (Icn) AC 230V 4.5 1: N pole is a switched neutral pole (without overcurrent release device). noperating Characteristics 4h 4h Operating Characteristics : Rated current : A~40A Amb.temp.:30 C 2h 1h 30min 20min 2h 1h 30min 2min Operating time Operating time 1min Max. 30s 20s s 5s Min. 30s s 5s 2s 2s 1s 1s 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.04s 0.02s 0.02s 0.01s 1min Rated current sensitivity 4min 2min Rated nonoperating current min min min 4min 0.01s 0. 0.7 1 1.13 1. 2 3 4 5 7 15 20 25 50 0 30 nouter Dimensions 500 Groundfault current (% of rated current sensitivity) X0% of rated current nambient Compensation Curve Test button M4 screw Residual indicator Ambient compensation 120 Current ratings (%) N N 8.4 3 Rated ambient temp. 130 70 max. 1 0 90 80 0 20 30 40 50 Ambient temperature ( C) 88 (rated ambient temp.: 30 C) terminal 12