P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

Similar documents
P17 plugs, mobile sockets and surface-mounting sockets «New range 16 and 32 A»

HYPRA Prisinter 16/32/63 A

P17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX

2. RANGE. RAL 7035 Cabinets Vertical version (external dimensions in mm) Square version (external dimensions in mm) Supplied with plain plate (2) (1)

Plugs, mobile sockets, panel mounting sockets, surface mounting sockets, P17 Tempra Pro IP44 and low voltage 66/67

Socket. Extension. Connector Box. Extension. IP 44 and IP 66/67 plugs, mobile sockets, socket outlets and appliance inlets

Marina Cabinets LIMOGES Cedex Telephone: Fax:

16/32/63A - IP44 plugs, mobile sockets, socket inlets and appliance inlets

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

TANK LINING RESISTANCE GUIDE I-19

TECHNICAL DATASHEET. Weatherproof LED luminaire ZALEDA EVOL II. 85,000 h product life. General characteristics. Mounting accessories.

TECHNICAL DATASHEET. Weatherproof LED luminaire DUNA FLEX Standard Plus. 50,000 h product life IK C. Applications recommendation

Plexo composable plate supports and boxes

Small on price, big on boot

TECHNICAL DATASHEET. Weatherproof LED luminaire DUNA FLEX High Efficiency. 70,000 h product life IK C. Applications recommendation

Issue One. Chemical Compatibility Guide

Strength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all.

Metallic Systems TYPE SPTC

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

Safety Performance WORLD PREMIERE. palazzoli.com 1

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

Swivel Joints Flexmaster Joints Part Number NH NH NH NH NH NK NK

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

Physical properties of PET resins. 1. Intrinsic Viscosity (IV)

Grommet TET. Cable glands. Basic Data. Application. Press the grommet into the hole.

Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines

High pressure industrial ball valves

APOVAC R Vacuum Systems

Information. Mechanical. Electrical. Chemical. Conversions & Calculations

FR PVC COATED RAINWEAR

Be prepared with Lutz. Safety is our concern

EN WORKMASTER HAZMAX BOOTS. Certification

TECHNICAL MANUAL COMPRESSION FITTINGS

Hose and Fitting Edition

Technical Manual TYPE 4X

Chemical Resistance Chart

KLINGER top-chem A milestone in PTFE gasketing KLINGERsoft-chem

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry

Catalog June Mounted Bearings

Q-Duct wiring duct. Q-Duct Wiring duct. Catalog number explanation QD 100 X 100 S G

MITSUBISHI ELECTRIC E1032. Installation manual. English MA

KLINGER KGS. Rubber-Metal-Gaskets Safe sealing of gases and liquids

MITSUBISHI ELECTRIC E1071. Installation manual. English MA00777A

Ducting & Ventilation Components

Chemical Resistance of Arnitel

KLINGER-KGS Rubber- Metal-Gasket

TEST REPORT: CHM12-01-LSM

Filtration efficiency: 99% or more HEPO2element

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

Replacement Tubes for Gillian Gas Detection Pumps

VentureClad Insulation Jacketing Tapes 1577 Series

When you need to be Sure, be Sure to be Ready! Warranty does not cover any shipping. Berm must be shipped back to factory prepaid.

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

Filtration efficiency: 99% or more

Pump Kits. More than just pumps

The Air Logic Division of Fred Knapp

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

Magnetic Drive Gear Pumps

Technical data. DKK compact conductor lines engb IS eps

General applications Chemical plant, oil refinery, power plant, steam, Dowtherm, fused alkali, fuel oil and gas

UNIBOX Series Enclosure and wiring accessories IP40-IP55

Halogen Free, Flame-retardant Polyether based TPU

This convenient system is made entirely of inert parts: glass, Baseline drift

material handling optibelt rr / rr Plus / hrr

Pump kits. We deliver values.

Control pressure switch series FF 4

ULTRA LOW FRICTION SERIES

Dynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.

TECHNICAL INSTRUCTIONS DGP

MM PISTON PUMP

Delta Intercontinental Pte Ltd Tel : Fax: Woodlands Industrial Park E1, #

MASTERBOX Series MASTERBOX SERIES DISTRIBUTION ASSEMBLIES

Eccentric. P l u g V a l v e. Versatile PIPE CONNECTIONS, REPAIR & FLOW CONTROL PRODUCTS FOR THE UTILITIES INDUSTRY

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Peristaltic Pumps MODELS TYPICAL APPLICATIONS FEATURES SR10/30 SR10/50 SR10/100 SR18 SR25

Colorimetric Gas Detector Tube System US Dollar Price List

Permissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

Plug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30

TECHNICAL INSTRUCTIONS DGPT2

MasterProtect 1870 / 1880

MM PISTON PUMP

FILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS

DX³ RCCBs - ID 4P up to 100 A


Product Information S/PA

Pneumatic components (F.R.L. unit Separated type) Safety precautions

P 17 Tempra Pro IP 44 - LV 16 and 32 A

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.

The Most Trusted Casters IN THE WORLD.

SERIE 2T SERIES 3T ASTM - A216 WCB, A216WCC, A351 CF8, A351 CF8M, A352 LCB, A351 CN7M, A105N, NO. Part Name Material

BOA-H Mat E Type Series Booklet

Atlantic stainless steel cabinet Cat. Nos : /01/02/03/04/05/06/07/08/09/11/12/13/

Rated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet

HEAVY-DUTY PLUGS & SOCKETS

TX³ RCCBs 2P up to 100 A

Transcription:

CONTENTS Page 5 555 09 5 555 29 5 555 59 5 555 9 1. General characteristics...1 2. Use...1 3. Range/Equivalence table...2 4. Dimensions..............................3 5. Technical characteristics...5 6. Installation....6 7. Connection..................... 7. Wiring diagram..................... 9. Standards - Regulations... 1. GENERAL CHARACTERISTICS - IP 66/67, 69 (mobile plug and socket) - Material: PA6 RAL 7042 - IK 09 The surface mounting and mobile are designed to deliver power where it is needed. The plugs are designed to equip portable or mobile electrical equipment (e.g. inspection lamps, compressors, welding equipment, etc.). When connected to a mobile socket, they combine to create an extension. 2. USE (CONTINUED) Quick and easy wiring Automatic sealing when the cable is inserted External thread forming screws 2. USE A. Fixed, surface mounting and appliance inlets - Screw connection - 5.5 screw with mixed PH2 (63 A) and PH3 (125 A) head (for 5.5 flat-blade or cross-head screwdriver) - Angle: - 20 for fixed - 15 (63 A) or 25 (125 A) for surface mounting - 35 (63 A) and 45 (125 A) for appliance inlets B. Mobile plugs and - Screw connection - 5.5 screw with mixed PH2 (63 A) and PH3 (125 A) head (for 5.5 flat-blade or cross-head screwdriver) - Integrated cable gland with clamp claws - Automatic sealing when the cable is inserted - Cable clamping achieved by simply tightening the cable gland - Captive cable gland - Screw-lock cable gland (PH1) Locking screw in locked position (PH1) 1/

3. RANGE/EQUIVALENCE TABLE P17 Tempra P17 Tempra Pro 200 to 250 V 63 A 30 to 415 V 63 A 125 A Description Fixed surface mounting Fixed surface mounting Fixed Fixed Mobile Mobile Straight mobile plugs Straight mobile plugs Appliance inlets Appliance inlets 2P+E 5740 5 555 54 5720 5 555 4 5710 5 555 04 5700 5 555 24 5730 5 555 14 3P+E 5741 5 555 55 5721 5 555 5 5711 5 555 05 5701 5 555 25 3P+N+E 5742 5 555 56 5722 5 555 6 5712 5 555 06 5702 5 555 26 3P+E 5744 5 555 5 5724 5 555 5714 5 555 0 5704 5 555 2 5734 5 555 1 3P+N+E 5745 5 555 59 5725 5 555 9 5715 5 555 09 5705 5 555 29 5735 5 555 19 3P+E 59106 5 556 5 59116 5 556 59136 5 556 0 59126 5 556 2 59146 5 556 1 3P+N+E 59107 5 556 59 59117 5 556 9 59137 5 556 09 59127 5 556 29 59147 5 556 19 40 to 500 V 63 A 3P+E 5534 5 555 62 5727 5 555 92 5717 5 555 12 5707 5 555 32 P17 Tempra P17 Tempra Pro Function Rating Polarity Voltage range 5710 5 555 04 Mobile socket 63 A 2P+E 200/250 V MOBILE SKT 63 A 2P+E 230 V IP 67 5711 5 555 05 Mobile socket 63 A 3P+E 200/250 V MOBILE SKT 63 A 3P+E 230 V IP 67 5712 5 555 06 Mobile socket 63 A 4P+E 200/250 V MOBILE SKT 63 A 4P+E 230 V IP 67 5714 5 555 0 Mobile socket 63 A 3P+E 30/415 V MOBILE SKT 63 A 3P+E 400 V IP 67 5715 5 555 09 Mobile socket 63 A 4P+E 30/415 V MOBILE SKT 63 A 4P+E 400 V IP 67 5717 5 555 12 Mobile socket 63 A 3P+E 40/500 V MOBILE SKT 63 A 3P+E 500 V IP 67 5730 5 555 14 Appliance inlet 63 A 2P+E 200/250 V CONNECT 63 A 2P+E 230 V IP 67 5734 5 555 1 Appliance inlet 63 A 3P+E 30/415 V CONNECT 63 A 3P+E 400 V IP 67 5735 5 555 19 Appliance inlet 63 A 4P+E 30/415 V CONNECT 63 A 4P+E 400 V IP 67 5700 5 555 24 Straight plug 63 A 2P+E 200/250 V STRAIGHT PLUG 63 A 2P+E 230 V IP 67 5701 5 555 25 Straight plug 63 A 3P+E 200/250 V STRAIGHT PLUG 63 A 3P+E 230 V IP 67 5702 5 555 26 Straight plug 63 A 4P+E 200/250 V STRAIGHT PLUG 63 A 4P+E 230 V IP 67 5704 5 555 2 Straight plug 63 A 3P+E 30/415 V STRAIGHT PLUG 63 A 3P+E 400 V IP 67 5705 5 555 29 Straight plug 63 A 4P+E 30/415 V STRAIGHT PLUG 63 A 4P+E 400 V IP 67 5707 5 555 32 Straight plug 63 A 3P+E 40/500 V STRAIGHT PLUG 63 A 3P+E 500 V IP 67 5740 5 555 54 Surface mounting socket 63 A 2P+E 200/250 V SURFACE SKT 63 A 2P+E 230 V IP 67 5741 5 555 55 Surface mounting socket 63 A 3P+E 200/250 V SURFACE SKT 63 A 3P+E 230 V IP 67 5742 5 555 56 Surface mounting socket 63 A 4P+E 200/250 V SURFACE SKT 63 A 4P+E 230 V IP 67 5744 5 555 5 Surface mounting socket 63 A 3P+E 30/415 V SURFACE SKT 63 A 3P+E 400 V IP 67 5745 5 555 59 Surface mounting socket 63 A 4P+E 30/415 V SURFACE SKT 63 A 4P+E 400 V IP 67 5534 5 555 62 Surface mounting socket 63 A 3P+E 40/500 V SURFACE SKT 500 V 3P+E 63 A IP 67 5720 5 555 4 Fixed socket 63 A 2P+E 200/250 V FIXED SKT 63 A 2P+E 230 V IP 67 5721 5 555 5 Fixed socket 63 A 3P+E 200/250 V FIXED SKT 63 A 3P+E 230 V IP 67 5722 5 555 6 Fixed socket 63 A 4P+E 200/250 V FIXED SKT 63 A 4P+E 230 V IP 67 5724 5 555 Fixed socket 63 A 3P+E 30/415 V FIXED SKT 63 A 3P+E 400 V IP 67 5725 5 555 9 Fixed socket 63 A 4P+E 30/415 V FIXED SKT 63 A 4P+E 400 V IP 67 5727 5 555 92 Fixed socket 63 A 3P+E 40/500 V FIXED SKT 63 A 3P+E 500 V IP 67 59136 5 556 0 Mobile socket 125 A 3P+E 30/415 V MOBILE SKT 125 A 3P+E 400 V IP 67 59137 5 556 09 Mobile socket 125 A 4P+E 30/415 V MOBILE SKT 125 A 4P+E 400 V IP 67 59146 5 556 1 Appliance inlet 125 A 3P+E 30/415 V CONNECT 125 A 3P+E 400 V IP 67 59147 5 556 19 Appliance inlet 125 A 4P+E 30/415 V CONNECT 125 A 4P+E 400 V IP 67 59126 5 556 2 Straight plug 125 A 3P+E 30/415 V STRAIGHT PLUG 125 A 3P+E 400 V IP 67 59127 5 556 29 Straight plug 125 A 4P+E 30/415 V STRAIGHT PLUG 125 A 4P+E 400 V IP 67 59106 5 556 5 Surface mounting socket 125 A 3P+E 30/415 V SURFACE SKT 125 A 3P+E 400 V IP 67 59107 5 556 59 Surface mounting socket 125 A 4P+E 30/415 V SURFACE SKT 125 A 4P+E 400 V IP 67 59116 5 556 Fixed socket 125 A 3P+E 30/415 V FIXED SKT 125 A 3P+E 400 V IP 67 59117 5 556 9 Fixed socket 125 A 4P+E 30/415 V FIXED SKT 125 A 4P+E 400 V IP 67 2/

4. DIMENSIONS Straight mobile plugs 63 A 2P+T : Ø14.1/27.6 3P+T : Ø15.7/30.1 3P+N+T : Ø17.5/33 Straight mobile plugs 125 A 3P+T : Ø23./47.5 3P+N+T : Ø26.4/50 20 / 256 232 / 216 Ø116 Mobile 63 A 2P+T : Ø14.1/27.6 3P+T : Ø15.7/30.1 3P+N+T : Ø17.5/33 145 Mobile 125 A 3P+T : Ø23./47.5 3P+N+T : Ø26.4/50 Ø135 310 / 26 25 / 243 125 Ø116 14 Ø135 3/

P17 Tempra Pro plugs, mobile, Cat. Nos: 5 555 04/05/06/0/09/12/14/1/19/24/25/26/ 2/29/32/54/55/56/5/59/4/5/6//9/92 4. DIMENSIONS (CONTINUED) Appliance inlets 63 A 106,5 6 M32 130 Fix. 117 22 30 20 77 5 106 53 2 Ø9 Ø6 Ø5.3 Fixed 63 A 4 77 292 270 155 Fixed 125 A 146 20 Ø1 Ø6 Fix. 234 77 4 20 146 73.5 M32 9 93 50 30 M20 35 Appliance inlets 125 A 16 170 Surface mounting 63 A 133 119 166 30 M32 M20 230 45 Fix. 260 355 300 M25/32 236 156 50.3 53 Ø6.3 Ø5 M50 15 40 M40 70 Fix. 152 220 290 Surface mounting 125 A 336 M20 230 65 326 300 Fix. 260 53 Ø6.3 170 M50(1) 40 M40 70 Fix. 152 265 (1) An M50/M63 cable gland adaptor with seal is required for a 70 mm2 connection Data sheet: F0235EN/01 Updated: 24/01/2017 Created: 26/10/2016 4/

5. TECHNICAL CHARACTERISTICS 5.1 Glow wire test - 50 C for mountings for live parts - 650 C for all other components 5.2 Insulation voltage 750 V Dielectric strength 3000 V 50 Hz 5.3 Operating temperature (plugged in and unplugged) Min. -40 C/Max. +55 C 5.4 Installation temperature (connection and/or mounting) Min. -5 C/Max. 40 C 5.5 Degree of protection No water or dust ingress IP 66/67 IP 69 (mobile and plugs) 5.6 Material characteristics Chemical agents Resistance of material Aqueous solutions Cold water...++ Hot water...- Steam...-- 5% saline solution...+ Hydrogen peroxide...- Water + washing powder...+ Water + surfactants...+ Formaldehyde...++ Alcohols Ethanol...++ Methanol...- Propanol...+ Butanol...+ Glycols Ethylene glycol...- Phenols...-- Cresols...- Bases Ammonia...+ Sodium hydroxide (soda)...................................-- Sodium hypochlorite (12 bleach)...- Potassium hydroxide (potash)...+ Strong oxidizing acids Concentrated acetic acid...-- Nitric acid 5%...- Sulphuric acid 10%...- Hydrochloric acid 30%...- Perchloric acid 70%...- Hydrofluoric acid 70%...- Chromic acid 50%...-- Phosphoric acid 30%...- Weak acids Diluted acetic acid < 25%...- Citric acid...+ Lactic acid...- Formic acid...-- Uric acid...++ 5.6 Material characteristics (continued) Chemical agents Resistance of material Animal oils and fats Lard....++ Butter, cream.... ++ Vegetable oils and fats Linseed oil...++ Groundnut/Olive oil...++ Castor oil....++ Glycerin...++ Mineral oils and fats Paraffin (Vaseline)... ++ Vehicle engine oil...+ Silicone oils...+ Cutting oils....++ Hydraulic oils....++ Hydrocarbons Unleaded petrol...++ Diesel...................................++ Kerosene.................................++ White spirit....+ Chlorinated solvents Trichloroethylene...- Trichlorethane...-- Perchlorethylene........................................... - Methylene chloride....-- Carbon tetrachloride...- Chloroform....- Aromatic solvents Benzene...+ Toluene...+ Xylene...+ Aliphatic solvents Hexane....+ Fluorinated solvents Trichlorofluoromethane...-- Ketones Acetone....+ Methyl ethyl ketone...+ Ethyl acetate...+ Terpenes Turpentine................................................. - Resistance to the risk of exposure to spraying of chemical agents at ambient temperature ++ Excellent resistance (continuous exposure) + Satisfactory resistance (long-term exposure) - Limited resistance (brief exposure possible) -- Poor resistance (exposure to be avoided) 5/

6. INSTALLATION Plugs and 2 1 4 4 - QUICK FIXING OF THE COVER Stainless steel captive mixed head screws for PH2 or flat-blade screwdriver (tightening torque 1.6 Nm to 1. Nm) provide a strong seal and corrosion resistance. 5 - EASY REMOVAL Live parts can be removed from the surface mounting socket to facilitate wiring and to change the angle of the socket. 1 - CABLE GRIP Captive cable grip with antivibration system holds the cable securely in place permanently. Equipped with a locking screw. Can be tightened by hand or using a 65 mm (for 63 A) or 2 mm (for 125 A) flat-blade tool with an adjustable spanner. 2 - CABLE STRIPPING Markings provide a quick guide to the user to indicate the cable stripping length. It is possible to use cables with ferrules. 3 - TWO SCREWS PER TERMINAL PH2 (63 A) and PH3 (125 A) mixed head screws for each connection terminal. 6 - RIVETED METAL SHAFT For 63 and 125 A models, the riveted metal shaft provides even greater durability. The notched locking ring facilitates cover opening and closing. A shutter retention system is also available on all. 6/

6. INSTALLATION (CONTINUED) 7 - POSITION MARKING The marking engraved on the ring cover provides a quick way to check whether the device is in the open or closed position. There is a space for a label on the socket cover or on the barrel of the plug for user identification purposes. 7. CONNECTION 7.1 Connection capacity Type Surface mounting socket and fixed socket Appliance inlet Mobile plugs and Rating Size of conductors (mm 2 ) Type of conductor 63 A 6 to 25 Rigid 125 A 25 to 70 (1) Rigid 63 A 6 to 16 Rigid 125 A 16 to 50 Rigid 63 A 6 to 16 Flexible 125 A 16 to 50 Flexible (1) Requires an M50/M63 cable gland adaptor with seal An IP XX B sleeve is included with 125 A fixed to protect against direct contact. Cross-sectional area of pilot wire 63/125 A Cable Fixed/surface mounting 2.5 to 10 mm 2 Rigid Appliance inlets 2.5 to 6 mm 2 Rigid Mobile plugs and 2.5 to 6 mm 2 Flexible with cable end - SPACE FOR MARKING OR ID LABEL 7.2 Connection terminal screw tightening torques - 63 A LV: 2 to 2.2 Nm for phases and earth 0.7 to 1 Nm for pilot wire - 125 A LV: 3 to 4 Nm for phases and earth 0.7 to 1 Nm for pilot wire 7/

. WIRING DIAGRAM Cut-out by pilot wire: The pilot wire is a control conductor associated with the power conductor. Its interruption controls breaking of the power circuit via a contactor. This arrangement provides an electrical response to the cut-out requirement for circuits rated higher than 32 A (conforming to the French decree dated 14/11/). An additional (shorter) pin is therefore added to the various socket models to provide this pilot wire function. 9. STANDARDS - REGULATIONS IEC 60309-1 and EN 60309-1 (design requirements) IEC 60309-2 and EN 60309-2 (interchangeability requirements) IEC 60529 and EN 60529 (IP) IEC 62262 and EN 62262 (IK) French decree dated 14/11/ (safety of workers) 2002/95/EC ROHS directive Example wiring diagram: 3P+N+ 3P+ L1 L2 L3 N Contactor with on/off push-button L1 L2 L3 Contactor with on/off push-button M Coil Coil A A Fuse Fuse Socket outlet Pilot L1 L2 L3 N Plug Mobile socket Pilot L1 L2 L3 N Appliance inlet 3P+N+ 3P+ To appliance /