Hydraulic and Commissioning Mannual Module 2A

Similar documents
A10VO. Variable Displacement Piston Pump Technical Information Manual Module 3A

CS-SCB Sander Control Block Manual

MP18/SIC & SIO Stacking Valve System Technical Information Manual

MP18 Stacking Valve System Technical Information Manual

Starting up hydraulic systems

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Radial piston pump PR4 series 1X

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

ENGINEERING DATA. Quick Reference Chart. Variable Volume Vane Pumps Models SV-20 & SV-25 Flange & Subplate Mounted. Industrial Hydraulics

Radial piston pump PR4 Series 1X

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Section 5: Hydraulic Pump SAUER DANFOSS. SERVICE MANUAL Property of American Airlines. 5-5 Page 1 September 09 HYDRAULIC PUMP

Pneumatic High-Viscosity Filtration System Instruction Manual

Radial piston pump, fixed displacement

Technical Information for PVX Series Pumps

Purging Air From Divider Block Lubrication Systems

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

CS 440RC. Solid De-icer Controller Operator Manual

Coolant Purification Systems Ultra 360 INSTRUCTION MANUAL

Low Profile J Series Power Unit with Vane Pump

Service Manual for Hydraulic Vane Pumps Subplate Mounted

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

PLUNGER PUMP SERVICE MANUAL

WARCO CHEMAG SERIES GH FILTERS

PV Series E, J, & L Piston Pump Installation Tips and Procedures

Coolant Purification Systems Ultra 360 INSTRUCTION MANUAL

EEiGl BOSCH. Engineering Data VARIABLE VOLUME VANE PUMPS MODEL SV-80 MODEL SV-100 QUICK REFERENCE FLANGE MOUNTED SYMBOL

Operating instructions Form no safety definitions

Operation & Service Manual

Operating Instructions & Parts Manual

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

CS 440RC. Solid De-icer Controller Closed-Loop Gate Control

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

PLUNGER PUMP SERVICE MANUAL

WALKIE HIGH LIFT HYDRAULIC SYSTEM

HIGH VISCOSITY FILTER SYSTEMS

OPERATION AND SERVICE MANUAL. McGILL UNIVERSITY PROJECT: MCS-3237 SUBJECT: HYDRAULIC POWER UNIT AND ROTARY ACTUATORS DECEMBER 2001

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Marine Engineering Exam Resource Review of Hydraulics

Operating Instructions & Parts Manual

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

TROUBLESHOOTING TABLE

Whisper Pumps VPV Vane Pumps

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

OPERATION AND PARTS MANUAL

Deister Machine Company, Inc. Heavy Duty System Saver Operating Instructions

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Axial Piston Fixed Pump A17FNO Series 10

Service Manual for Hydraulic Vane Pumps Flange Mounted

MODEL 10LH SPECIFICATION

Fixed displacement radial piston pump

INDEX. 1. Introduction. 2. General Guidelines. 3. Hydraulic Fluids. 4. Installation & Start up Procedures. 5. Trouble Shooting Guide & Maintenance

Coolant Purification Systems Ultra 90 INSTRUCTION MANUAL

Installation and Operation Instruction Manual INSMAN-201. Industrial Multi Media Single Tank

Air / Hydraulic Under Axle Jack

Trailer Brake System Bleeding Procedure:

Low Pressure Transfer Systems

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Low Oil Controller Installation and Operations Manual. CS SS07-A2 P/N Enclosure

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

To ensure proper installation, digital pictures with contact information to before startup.

Piston Pumps PVH Variable Displacement

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

Fixed displacement vane pumps Types PVV and PVQ

Hydraulic Pump Series VP1 Variable Displacement

Routine Compressor Maintenance

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

ICSV3003 SALT AND SPREADER MODULE

Series RFL In-Line Filter

Installation And Operation Instruction Manual INSMAN-101. Sand Media Filters. Phone: Toll-Free:

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

LogSplitterPlans.Com

Air/Hydraulic Actuators

Motor-pump group. Features. Table of contents RE 51171/ Type ABAPG and ABHPG

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Backflow Irrigation Control Station BIC-1000

Vane pump, direct operated

Before you go through this booklet, we request you to go through the following general instruction before commissioning your hydraulic systems.

HYDRAULIC SYSTEM, ISL-07

Vacuum Accumulator System

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

SECTION 1 LUBRICATION

CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

Product Manual (Revision NEW) Original Instructions. PGA Governor. Installation Manual

Lecture 32 MAINTENANCE OF FLUID POWER SYSTEMS

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS)

2.4 HEAVY DUTY SERIES

Installation & Operation Instruction Manual FWINSMAN300. Yardney - Filtaworx FW02 - FW03

SERVICE INSTRUCTION PURGING OF LUBRICATION SYSTEM FOR ROTAX ENGINE TYPE 912 AND 914 (SERIES) SI SI Repeating symbols:

Single, Double, Triple, and Thru-Drive Pumps Overhaul Service Manual

Axial Piston Variable Pump A10VSNO

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

Transcription:

Hydraulic and Commissioning Mannual Module 2A

2/7 Table of Contents 1 Features 3 2 Hydraulic Commissioning 3 2.1 Functional Purpose 3 2.2 System Description 3 3 Hydraulic Commissioning Instructions 4 4 Additional Information 6 4.1 Filtration 6 4.2 Filter Inspection 6 4.3 Oil Replacement 6 4.4 Oil Tank (Reservoir) 6 Bosch Rexroth Canada Corp. reserves the right to revise this information at any time and for any reason and reserves the right to make changes at any time, without notice or obligation, to any of the information contained in this piece of literature. Please check for updates at: www.boschrexroth.ca/compu-spread

3/7 1 Features High efficiency Open or closed centre configuration Accurate/smooth control Long service life 2 Hydraulic Commissioning 2.1 Functional Purpose The purpose of following a special commissioning or start-up procedure after installation of a new or overhauled system is to accomplish four major objectives. This procedure can be followed for any type of hydraulic spreader system start-up. The objectives Start-up pump at no load Flush System at high and low pressure Bleed air and fix leaks Verify performance and function 2.2 System Description The Compu-Spread Hydraulic System will consist of either a fixed displacement (open centre system) or a variable displacement (closed centre system) pump. Combined with and appropriate Basic Technologies valve bank, all hydraulic functions can now be controlled. The hydraulic system is optimized with an electronic control system for instant response, accurate control, high efficiency, and long life.

4/7 3 Hydraulic Commissioning Instructions Refer to hydraulic installation and commissioning drawing. Note: These instructions are for variable displacement pump systems. If your system is equipped with a fixed displacement (gear or vane) type pump, there will be no pump adjustments available, and no case to fill. However, you will need to set the maximum system pressure by turning the adjustment screw located on the inlet of the valve bank. To do this, simply ignore Step #9 and apply Steps #4 and #11 at the valve rather than at the pump. The standby setting is fixed in the valve and should read approximately 150 PSI. 1. Ensure all components are flushed clean and free of grit and dirt. 2. Fill the reservoir and pump only through a fine filter (i.e. 10 micron absolute) to avoid adding more contamination to the system. Important: Fill pump and motor cases to the highest case drain or vent port. Use clean filtered fluid. Note: Drum and bulk oil is dirty by hydraulic oil standards. Care should always be taken when filling or topping off the reservoir by using a filling filter. 3. Ensure all hoses, fittings, etc. are tightened correctly. Note: All pipelines must enter the tank sufficiently far below the minimum permissible oil level (approximately 2 inches (5cm)) so as to prevent foaming. 4. Turn the maximum pressure adjustment screw on the pump control counter clockwise as far as possible. Do not adjust standby pressure. 5. Disconnect the pressure and tank lines from the valve bank. Couple these lines together to create a non-restricted flow path from the reservoir through the pump, through specified filter (i.e. 10 micron absolute) then back to the reservoir again. 6. Start prime mover to allow system to fill with fluid and ensure adequate lubrication. If the pump is not delivering fluid free of air bubbles within 60 seconds, shut down and check the system again. If okay, and no leaks and all sounds well, allow system to run for a few minutes to purge any entrapped air. 7. Shut the system down, uncouple the pressure line from the tank line and reconnect them to the valve bank. Also, install a 3000 PSI pressure gauge in the pressure line from the pump (this may be easily accomplished by installing test fitting P/N101077 into the test port of the variable displacement pump. See detail "C" of the Hydraulic & Commissioning drawing). 8. Start the prime mover again. 9. Check the standby pressure. Pressure gauge should read 200 PSI as per factory setting. If not, adjust to read 200 PSI by turning small adjustment screw clockwise to increase or counter clockwise to decrease.

5/7 Note: In some applications it may be necessary to increase standby pressure, do not exceed 300 PSI. 10. To set the maximum system pressure you will have to Deadhead one of the valve functions (i.e. fully extend a cylinder or plug off a working port while keeping that valve section shifted). 11. While Dead Heading turn the large adjustment screw on the pump clockwise. Turn until you read the maximum pressure your system requires on the pressure gauge (usually 1500-2500 PSI). 12. Ensure you lock both pump adjustments in place with the jam nuts. 13. Releasing the valve function will cause pressure to drop back down to the standby setting. 14. Push in the solenoid override pins of the spinner and conveyor sections to assure correct function and rotation. 15. Run the system under load until oil reaches operating temperature (should not exceed 140ºF) and check for leaks. 16. Ensure there is still a sufficient quantity of oil in the reservoir now that all lines, etc. are full. 17. Erratic operation may indicate there is still air trapped in the system. By working control valves both ways the remaining air can be eliminated. The system is free of air when all functions can be operated smoothly and the oil in the reservoir shows no foam on the surface.

6/7 4 Additional Information 4.1 Filtration In order to guarantee reliable function, the hydraulic fluid should be filtered through a 10 micron absolute filter. 4.2 Filter Inspection In good practice ensure filters are inspected within the following time frames. 1. Daily after commissioning 2. If free of contamination, weekly 3. After approximately 100 operating hours, monthly 4.3 Oil Replacement 1. After the first 500 hours of operation 2. After the following 2000 operating hours 3. Every 2000 operating hours thereafter or once a year When changing the oil, ensure the fluid used is capable of bridging both summer and winter temperature ranges while maintaining the minimum viscosity at operating temperature. Common errors made in practice during an oil change: Lack of cleanliness (dirt introduced into system) Failure to clean tank Filing of tank without filter 4.4 Oil Tank (Reservoir) The capacity of the tank must be selected to suit the operating conditions. The suction and return lines should be arranged so as to allow free flow. All pipelines must enter the tank sufficiently far below the minimum permissible oil level so as to prevent foaming. An air breather is necessary for volume compensation due to varying work cycles and temperature fluctuations and should be fitted at the highest point on the tank.

7/7 Notes: