reedom to move around in a arrier free environment. The lifting appliance for wheelchair users that makes it simple to overcome staircases of a few steps or several levels. Platform tairlift
unctionality and safety in a single solution Easy to use thanks to the platform and armrests motorised movement, Arcoift allows overcog a few steps or several floors in a simple and safe way. Appropriately designed landing connection ramps to imise inclination for an effortless access to the platform. The Opening and Closure of the platform and armrests are comfortaly operated from the landing push utton control panel. Arcoift, in the rest position does not ostruct the staircase thanks to fold away platform and armrests. aximum hygiene and cleanliness is guaranteed y installing a dry guide rail not requiring oiling nor lurication. Arcoift adapts to any type of staircase either it e straight or curved, as well as for internal and external environments. EC CONORITY TO EUROPEAN TANDARD. achinery Directive 2006/42/EC. E..C. Directive 2004/108/EC. afety requirement for tairlifts EN 81-40 tandard Technical Data OD P108 Rated oad 250 Kg peed 6 m/ (0,10 m/sec) Battery Charger Power Consumption Protection level IP55 Internal curving radius 200 mm External curving radius 0 mm ax. Inclination 40 The characteristics of the installation site are inding on the feasiility and lift type.
Useful Information Basic features Arcoift od. P108 Automatic landing ramps with ripface surface and Oversize dimensions to facilitate access to the platform y wheelchair users otorised platform with anti-slip floor otorised armrests, closing within the platform at the rest position against acts of vandalism Up / Down push uttons integrated on machine ody requesting a constant pressure for operation ireless push utton control panels at landings activated y key, operating Call / Return controls (requiring a constant pressure) and Platform Opening / Closing control (One-touch) On / Off activation switch with extractale key Emergency stop utton is fitted on the machine ody 24V attery operated rechargale at the guide extremity afety sensors on the automated movements of the platform and armrests afety sensors under the platform and on the machine ody against the risk of impact or crushing during movements Parachute and overspeed controller safety devices Electrical and mechanical limit stops on the guide extremities tandard finishing: white machine ody, dark grey platform floor dark gray rough finshed guide rail Environmental service conditions: -10 C / +40 C for indoor or outdoor environment (not severe or extreme conditions) Arcoift options Direct power supply connection kit: tension 115/230V 50/60Hz, consumption 1 Kw Direct landing control panels (availale only with direct power supply connection kit) Extendale push utton control panel for ground attendant oldale seat Protective cover ovement warning lights along the path ovement warning light or acoustic signal on oard oldale guide rail at lower extremity or intermediate position
OVERA DIENION D E H H1 l a C TAIRIT OVERA DIENION Net Dimension a C D E H Access N * Access H1 900 1170 1090 1270 390 480 1 1440 2040 1440 1920 900 1170 1040 1220 390 510 1 1440 2040 1440 1870 900 1170 990 420 1 1440 2040 1820 900 1170 900 420 1 1440 2040 1770 * Approximate for 30 guide rail inclination Dimensions expressed in mm
Dimension Chart 1 > Parking Position at lower level PATOR ACCE UTIITIE N - Opposite uggested manoeuvring spaces for wheelchair 1,7 m 1,4 m A - Adjacent (90 ) 90 Curve 1,4 m - rontal (same side) 1,4 m 90 Rotation Correct use of the stairlift ANDIN CONNECTION TYPE T TYPE type = tandard T type = Rounded off
Dimension Chart 1 > Parking position at lower level ET IDE INTAATION X (ET IDE) XR eft side straight parking position RIHT IDE INTAATION DX (RIHT IDE) DXR Right side straight parking position X90 eft side 90 parking position ( curve) DX90 Right side 90 parking position ( curve) X180 eft side 180 parking position (U curve) DX180 Right side 180 parking position (U curve) XINC oldale guide in parking position** DXINC oldale guide in parking position ** ** traight parking only
Dimension Chart 2 > uide rail configuration TRAIHT TAIRCAE 90 INTERNA CURVE P108-1140 1320 P108-1300 1370 P108-1090 1270 P108-1250 1320 P108-1040 P108-0 X P108-0 X P108-1 T T P108-1140 P108-1250 P108-1090 P108-0 P108-1040 P108-1 X P108- X P108-
Dimension Chart 2 > uide rail configuration 90 EXTERNA CURVE 180 INTERNA CURVE 2 1 3 1 2 1 2 3 max P108-1180 1320 P108-1300 2 1370 2840 P108-1145 1270 P108-1250 2 1320 2740 P108-1110 P108-0 2500 X P108-1075 X P108-1 2400 T T 1 2 1 2 3 max P108-1180 P108-1300 2 P108-1145 P108-1250 2500 P108-1110 P108-0 2400 X P108- X P108- Dimensions expressed in mm
Dimension Chart 2 > uide rail configuration / ixing solutions 180 EXTERNA CURVE UIDE RAI OUNTIN A Type ixing: to the tep P 2* P 160 kg 80 kg 1 1 3 1 Type ixing: To all 1 3 1 3 2 P108-1180 280 1320 50 2690 P108- P108-1145 1110 350 420 1270 2640 2640 P X P108-1075 420 2640 T 1 3 1 3 2 P108- P108- P108-1180 1145 1110 280 350 420 2640 2640 2640 P 160 kg 260 kg X P108- * 3 > 3 AX -> 2 = 2 IN + (3-3 AX)
Chart 3 > Power supply > Battery charger BATTERY CHARER 156 x 48 x 80 mm P 5! 1 2 3 4 Pn P0 loor 0 - ower anding Pn Intermediate loor Ps Upper loor Return ANDIN CONTRO PANE DETAI Pn P0 Up / Ascent 1 - Connection to the electrical power line! The customer shall provide a power line (INPUT 115/230V 50/60 Hz) fitted with a mains socket for plugging in the attery charger: - The power line shal e fitted with a thermal magnetic circuit reaker (10A, trip sensitivity 30mA, C trip curve). The distance etween the socket and the feeding point on the guide rail shall not exceed 2,5 m. Power Consumption 1A - Power 0,1 k 2 - Connection cale from the attery charger to the plug Connection cale fitted with European plug for the connection of the attery charger to the mains socket. (Other kind of plugs are availale as an optional request) 3 - Connection cale from the attery charger to the power charging point on the guide rail 4 - Power Charging Point - OUTPUT 24V 3A The standard layout includes one power charging point installed at one of the guide rails extremity (lower or upper floor). Additional power charging points are availale as an optional request. 5 - Battery charger The attery charger cannot e directly exposed to weather elements or to humidity. Environmental operating conditions: Humidity:10% to 95%, Temperature: 0 C to 30 C If installed in a cainet, a suitale aeration shall e guaranteed. uggested Cainet imum dimensions: 300 x x mm (inside maximum temperature shall never exceed 30 C) IREE ANDIN CONTRO PANE 1,5 m AX Close Charging ED Down / Descent Transmission ED Call and Return uttons: Their operation requires constant pressure Open and Close uttons: One-touch automatic type control to operate platform and armrest movements 0,9 m IN / 1,1 m AX 6 - tandard control panel at floors operate with remote control Action radius of the wireless control panels: 20 m tandard mounting: to the wall Dimensions: 75 x 110 x 60 mm Power supply: 4 x 6 AAA 1,5V
Chart 3 > Power supply > Direct Power supply AIN POER UPPY CONNECTION 350 x 365 x 210 mm P 4! 1 2 3 Pn Pn P0 loor 0 - ower anding Pn Intermediate loor Ps Upper loor Return ANDIN CONTRO PANE DETAI P0 Up / Ascent 1 - Connection to the electrical power! The customer shall provide a dedicated power line: INPUT voltage115/230v 50/60 Hz) The power line shall e fitted with: - a thermal magnetic circuit reaker (10A, trip sensitivity 30mA, C trip curve) - A cale 3 x 1,5 m2 for the connection to the controller cainet. (imum tue diametre to allow the cale passage: 20 mm) Note: The line shall e fitted with a connection to earth Power consumption: 8A - 1 k 2 - Connection from the cainet to the guide rail The customer shall provide a suitale tue passage diameter 20 mm. to hold the connection cale (Cale 2 x 6 mm2) 3- Power feeding point - OUTPUT 24V 40A The power feeding point is placed at one of the guide rails extremity (lower or uper floor). 4 - Controller cainet The cainet shall e mounted to the wall and e easily accessile for maintenance purposes (suggested height 1,5m) The cainet cannot e directly exposed to weather elements or to humidity. Environmental operating conditions: Humidity:10% to 95%. Temperature: 0 C to 30 C uitale aeration shall always e guaranteed. ANDIN CONTRO PANE CONNECTION 1,5 m AX Close Call and Return uttons: Open and Close uttons: Down / Descent Their operation requires constant pressure One-touch automatic type control to operate platform and armrest movements! 0,9 m IN / 1,1 m AX 5 - tandard control panel at floors operate with remote control Action radius of the wireless control panels: 20 m tandard mounting: to the wall Dimensions: 75 x 110 x 60 mm The customer shall provide: - A tue passage for cales:. diametre 20 mm! 5
KE---P-0211-EN anufacturing and Premises ITE R Via Cavalieri di Vittorio Veneto 23870 Cernusco omardone - C (Italy) Tel +39 039 999 18.1 ax +39 039 999 18.55 info@sites.it Data, technical features and finishing are non-inding and may change without notice www.freelifestyle.eu