Side Delivery Unit Installation

Similar documents
Flex Work Station Delivery Units Installation Guide

Loose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:

Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

Product Name Chair Conversion Kit (to Console Delivery Unit) Installation [Kit # xx]

Track Light with Monitor Installation Guide

Midmark Cabinet / Wall Light Installation

Midmark Track Light Installation

Knee Crutches / Cladding [9A410 / 9A411 / 9A412 / 9A413]

Cascade 3072 Delivery System INSTALLATION GUIDE

Installation Instructions: Side Delivery Units BDS-2555

Midmark Light Install: L/R mounted on Ultra Chair

Product Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx]

PowerAir Compressor Installation

Asepsis 21 Delivery Unit

Spring Bearing Rocker Replacement Installation [Kit # ] for Elevance Continental-Style Delivery Unit

A-dec 542 Side Delivery System I NSTALLATION GUIDE

Wall / Casework Mounted Delivery Systems (Procenter)

Master Slave Converter [ VAC & VAC]

270 Series Stools. 270 Series. Service and Parts Manual. Serial Number Prefix: V & VAB. (270 thru 279) FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY

630 (-010 thru -013, -020 thru -023)

Chase Rectangular and Pentagonal Units

FLIGHT SIMULATOR SYSTEMS

ClassicSeries Compressor Installation

491 Harness Installation Kit

Installation Manual. 355 Lighting System

Asepsis 21 Delivery Systems

INSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580

Section 10. Cycle Times - Pressures - Adjustments For: L130F-109 LUMBERJACK

Installation Instructions: Swing Mounted Units BDS-2575

Cylinder Rod End Replacement Kit [ ]

Features: Positive on/ off control Brass construction Nickel plated Port size Panel mount with nuts, 15/ black gray.

SHOP PRO FXP 95 UPGRADE KIT (REGULATED)

Installation Instructions X-Force UTV Lift (000 Series) Capacity 2,275 lbs (1,035 kg)

Monitor Support Arms. Service and Parts Manual Part / Kit Numbers:

Series 2003T. Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS. To be used with H210 C2150 Ver.10 Control Setup Instructions

INSTALLATION INSTRUCTIONS

-001. Air Lift Physician Stool. Serial Number Prefixes: BZ, V & VAF FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY -001

Veterinary Anesthesia Gas Scavenging System (Active)

Installation. minnkot amot or s.com

Section 10. Pressure Adjustments For: L90F-622 LUMBERJACK

CIRRUS AIRPLANE MAINTENANCE MANUAL

Installation Manual 354 / 355 Combination Lighting System

Belt Conveyor Systems

60-72 Chevrolet C10 Power Rack & Pinion Kit Instructions # , , &

Veterinary Synthesis TM Table Parts List

Installation Instructions for Swing Mount System

Troubleshooting Guide: 355 Lights (24V)

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

Parts manual. Models: /ZEKW /ZEKW /ZEKW48190 MANUAL NO REV. IR (06/26/06)

Plasma Dual Swing-Out (PDS Series) Wall Mount

Installation Manual. 355 Lighting System MA326100

Mega-Flow External Damper Fans

Installation Manual for Philips SureSigns VS3/VS4/VM4/VM6/VM8/VSV VHM-25 Countertop Mount

Operation Manual. 355 Lighting System. Safety 2. Features 4. Component Overview 5. Controls & Indicators 6. Operation 7.

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 255 LED Light

CIRRUS AIRPLANE MAINTENANCE MANUAL

ClassicSeries Wet-Ring Vacuums Single Model Numbers: CV3 CV3R CV5 CV5R CV6 CV6R CV10 CV10R. Service and Parts Manual

CHAPTER 1C PREPARING FOR INSTALLATION

INSTALLATION INSTRUCTIONS For 65800, 65801, 66355, 69250, Rear Bumper And Tire Carrier For Jeep XJ Cherokee

H.I.T Truck Tire Changer. Parts Identification

A-dec O Clock Delivery System

Midmark Dental Lightheads

INSTRUCTION, HALDEX PUMP LVS KIT P/N

CIRRUS AIRPLANE MAINTENANCE MANUAL

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

Installation and Service Manual

VetVision DC X-Ray System

Detroit Speed, Inc. Rear Coilover Tower Brace Kit Camaro P/N:

Amdent Scaler System ( ) Installation Guide

Installation Instructions Studio Makeup Station

Flex Fuel Bluetooth Kit BRZ / FRS / GT86 install instructions

Procenter Delivery Systems

Some service parts may not be available for this product!

A-dec 541 Delivery System and 545 Assistant s Instrumentation

xpressstart Mercedes Solution Mercedes Benz S and CL Class

ROSBACK PRINTERS AND BOOKBINDER S MACHINERY Quality Bindery Equipment Since 1881

INSTALLATION AND PARTS MANUAL

INSTALLATION AND PARTS MANUAL

1/2 Ton Tahoe/Suburban/Yukon/Avalanche 4wd Part #: Rev

A-dec 2122/2132 Radius System on A-dec 511 Dental Chair I NSTALLATION GUIDE

PowerMax PM-1 PM-3 PM-4. Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers:

INSTALLATION INSTRUCTIONS

MANPOWER REQUIREMENTS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Vertical Toaster Idler Installation Kit

Addendum to VT Tensioner Kit Instructions

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

NO LONGER IN PRODUCTION Some service parts may not be available for this production

Installation Instructions

Yaw Control and Trim. 1. General. A. Yaw Control System. B. Yaw Trim System

Service and Parts Manual

Mounted Instrument Head

PARTS MAN UAL SDA-1200 STEER ABLE DRIVE AXLE SDA-1400 STEER ABLE DRIVE AXLE SDA-1600 STEER ABLE DRIVE AXLE

GENUINE PARTS INSTALLATION INSTRUCTIONS

CIRRUS AIRPLANE MAINTENANCE MANUAL

Dental Chair Midmark UltraComfort & UltraTrim Dental Chair

Part # Mustang Tru-Turn Suspension Package

Transcription:

Side Delivery Unit Installation CONTENTS Mounting Location... 1 Minimum Cabinet Size Requirements... 1 Mounting Requirements... 1 Regulator Installation... 2 Cabinet Mount Bracket Installation... 2 Wall Mount Bracket Installation... 3 Bracket Installation... 4 Unit Arm Installation... 5 Stop Pin Installation... 5 Flex Arm Lock Activation & Leveling... 6 Tubing Connections... 7 Dimensions, Range of Motion... 8 Electrical Requirements: 24VAC, 3.2 amp 13VAC, 2.0 amp Mounting Location Minimum Cabinet Size Requirements (Side Delivery) 55 to 61 in. (139.7 to 154.9 cm) Verify desired position (ex. RH / LH) with proper personnel before installation. Short Flex Arm 17 in. ( 43.2 cm) 27.5 in. ( 69.8 cm) Short Flex Arm 28 in. ( 71.1 cm) 36 in. ( 91.4 cm) Flex Arm Fixed Arm 12 to 24 in. (30.4 to 60.9 cm) Mounting Requirements Mounting Structure The mounting structure must be capable of supporting the weight / torque listed below without deflection: Unit / Arm Assembly Weight (Maximum)... 50 lbs (22.6 kgs.) Torque (Maximum)... 170.8 ft-lbs. (231.5 N M) To prevent the unit from drifting, the mounting plate must deflect no more than 1/16" (1.6 mm) over a 12" (30.5) distance. 1 003-1292-00 Rev. LA1 (9/17)

Regulator Installation Step 1: Insert regulator assembly into compression fitting of shut-off. Tighten compression fitting. WATER REGULATOR Compression Fitting AIR REGULATOR Compression Fitting Shut off Valve Regulator Shut off Valve Regulator Cabinet Mount Bracket Installation (Cabinet Mount Units Only) Midmark Freestanding Center Console cabinets are pre-drilled and it is not necessary to do the following step. Step 1: Using the below dimensions, mark position of four mounting holes for bearing plate. Use a 1/4" drill bit to drill holes. Left Hand Cabinet Mount The bearing plate can be mounted with the needle bearing at the top or bottom. It is recommended that the needle bearing is positioned at the Top. Right Hand Cabinet Mount 3-5/8" (9.2 cm) 14 3/4" (37.5 cm) Needle on Bottom. 8.0" (20.3 cm) Needle on Top. 2-3/4" (6.9 cm) 2

Cabinet Mount Bracket Installation (continued) (Cabinet Mount Units Only) Step 3: Loosen bolts and level bearing mounting plate. Use shims, if necessary, then tighten bolts. Backing Plate is not required on Midmark Freestanding Center Console Cabinets. Level Backing Plate Step 2: Align mounting holes and install appropriate mounting bolts. Bolts are provided in 1" and 2 1/4" lengths. Plate Shim Wall Mount Bracket Installation (Wall Mount Units Only) Wall mounted units may be mounted at any height. Verify position with proper personnel. The bearing plate can be mounted with the needle bearing at the top or bottom. It is recommended that the needle bearing is positioned at the Top. Needle on Top. 16-7/16" (41.7 cm) 21-11/16" (55 cm) Floor 66-5/8"(169.3 cm) Long Fixed & Flex Arms 48-1/8"(122.3 cm) Short Fixed & Flex Arms Product can be configured to use either Fixed Arm with either Flex Arm. 3

Wall Mount Bracket Installation (Wall Mount Units Only) Equipment Alert Mounting Holes MUST be aligned with wall studs. Failure to comply could cause delivery unit to fall and damage unit and wall structure. Wall Studs Step 1: Locate wall studs. Align 8 holes in mounting plate with studs. Mark and drill pilot holes (Use 1/4" drill bit). Step 3: Install mounting cover using 4 #10-32 x 3/8" screws. Step 2: Secure frame to wall with 8 (5/16"x 2 1/2") lag screws. Bracket Installation The bearing plate can be mounted with the needle bearing at the top or bottom. It is recommended that the needle bearing is positioned at the Top. Level Frame Cover Step 2: Loosen bolts and level bearing mounting plate. Use shims, if necessary, then tighten bolts. Needle Step 1: Align mounting holes in bearing plate and frame cover. Install four screws Plate Shim 4

Unit Arm Installation (Cabinet & Wall Mount Units) Step 2: Apply lubricant, supplied with arm assemby, to Fixed Arm. Equipment Alert All pivots points must be secure when installing unit arm. Failure to comply could result in equipment damage. Step 4: Adjust drag by loosening / tightening set screw. Step 6: Install bearing cover. Cover Step 1: Loosen set screw. Set Screw Step 7: Install water bottle. Step 5: Trim umbilical sleeve. Slide sleeve over tubing & wiring. Install and secure umbilical retainer. Stop Pin Installation (Cabinet & Wall Mount Units) Retainer Step 3: Route umbilical tubing thru bearing and slide Fixed Arm into bearing. Step 8: Connect tubing. (Refer to Tubing Diagram). Step 2: Lift trim ring. Trim Ring Rotation Stop Screw Stop Pin Trim Ring Rotation Stop Screw Stop Pin Stop Pin Fixed Arm The stop pins can be placed in two positions, as determined by rotational stop screw. Verify desired position with customer. Position A Position B Step 3: Rotate flex arm to desired position and install stop pins. Flex Arm Step 1: Position Flex and Fixed Arms as shown. 5

Flex Arm Lock Activation / Leveling the Delivery Unit. The following procedures should be performed after installation of entire operatory is complete. To activate flex arm lock... A. Remove end cap. B. Slide cover back to access locking pawls. C. Cut and remove wire tie. D. Slide cover in position and install end cap. Locking Pawls Wire Tie Button Head Screws 2 3 4 1 Leveling Screws To level the delivery unit... A. Remove bottom cover. B. Slightly loosen button head screws. C. Adjust leveling screws until delivery unit is level. D. Tighten button head screws. E. Install cover. DA115102i 6

Tubing Connections 30 PSI 80 PSI 7

Dimensions, Range of Motion 30 12.5 in. ( 31.7 cm) Short Flex Arm 8.3 in. ( 21.1 cm) 180 Max.* 66.6 in. (169.3 cm) Min.** 48.2 in. (122.3 cm) Short Fixed Arm 13.5 in. ( 34.3 cm) 24 in. ( 60.9 cm) Short Fixed Arm 13.5 in. ( 34.3 cm) Long Fixed Arm 24 in. ( 60.9 cm) 180 Short FlexArm 16 in. ( 40.6 cm) 24 in. ( 60.9 cm) 135 Max.* 66.6 in. (169.3 cm) Min.** 48.2 in. (122.3 cm) 135 Short Flex Arm 16 in. ( 40.6 cm) 24 in. ( 60.9 cm) * Measurement w/ long fixed arm & long flex arm (Standard w/ wall mounted unit ).] ** Measurement w/ short fixed arm & short flex arm (Standard w/ cabinet mounted unit). Product can be configured to use either fixed arm w/ either flex arm. Midmark Corporation 60 Vista Drive P.O. Box 286 Versailles, OH 45380-0286 937-526-3662 Fax 937-526-5542 www.midmark.com 8