Keysight Technologies EV1003A Hybrid-Electric/Electric Vehicle Power-Converter Test Solution

Similar documents
Keysight Technologies RP7900 Series Regenerative Power System

Keysight Technologies Benefits of Moving to 1,500 V Photovoltaic Inverters. Application Note

RP7900 Series Regenerative Power System

Keysight BT2191A Self-Discharge Measurement System

Keysight Technologies Battery Temperature Profiling While Charging and Discharging. Application Note

Keysight Technologies 5530 Dynamic Calibrator. Data Sheet

Keysight Technologies Temperature Measurement Solution for Solar Cell and Module Testing. Application Note

Keysight Technologies Battery Testing. Application Note

Keysight Technologies Seven Practices to Prevent Damaging Power Meters and Power Sensors

Keysight Technologies Emerging Solutions to Hybrid & Electric Vehicle DC:DC Converter Design and Test

Evaluating Battery Run-Down with the N6781A 2-Quadrant Source/Measure Unit and the 14585A Control and Analysis Software.

Keysight Technologies Challenges and Solutions for Power Testing in Automotive Applications. Technical Overview

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Selecting DC Sources for Telecommunications Equipment Test Systems

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

HC1, HC2 and HC9. Helmholtz Coil Systems

Keysight Technologies Challenges and Solutions for Power Testing in Automotive Applications. Technical Overview

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Information Technology and Economic Development: An Introduction to the Research Issues

Packing Data Installation Instructions

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

CASE STUDY. LINK Engineering Company Inc. Resolving Customers Brake Noise Issues

Infographics on Electromobility (January 2019)

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

BP Statistical Review of World Energy June 2017

Testing Energy Storage Systems: From EVs to Utility Grid

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

Allen-Bradley 1397 Pulse Encoder Interface Card

Dynamic DC Emulator Efficient testing of charging technology and power electronics

Features MICRO-0.25-I MICRO-0.3-I PRODUCTS PANEL

Low Profile DC Power Supply with Zero Voltage Soft Switching

TOP SMART intelligent position monitor:

Power Supply And Electronic Load In ONE

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output

02 Keysight Installation and Maintenance of Solar Photovoltaic Systems - Application Note. Contents

Model Number Structure

Fork through-beam sensors

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Type Number Symbol Value Units

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Rectangular photoelectric proximity switches

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Mineral Industry. Drive solutions for reclaimers, stackers, bulk conveyors applications

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

CASE STUDY. A World Leader in a Niche Market. PAPST Fans Testing and Development of Automotive Fans. Germany. Automotive, Industrial, Consumer

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

D Series: UPS UPTO - 300KVA - Three / Three Phase

Global Medium & Heavy Commercial Vehicle Model Level Production Forecast Report. From 2001 to 2021

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

DH50 SERIES. DATASHEET Rev. A

i400s Calibration Information Introduction

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

Go to to register your product and find more information.

INITIATING AND FUNDING R&D. IGRC 2014 Copenhagen September Brad Douville, Vice-President, Westport

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Open Frame Power Supplies

RPS TL-UL System. Solutions for the North American Solar Market

Table B1. Advanced Economies: Unemployment, Employment, and Real per Capita GDP (Percent)

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Spain s exports by oil product group and country of destination. Year Corporación de Reservas Estratégicas de Productos Petrolíferos

(typ.) (Range) Load

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

596 Rectifier Retrofit

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production

FEDERAL RESERVE statistical release

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

AC/DC Converter MBP250-2A13D13M

David Meek. Engineering Director Intertek Transportation Technologies. Sponsors

LS200 Series Instruction Manual

GB60S 60W Single Output General Purpose Series

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

General Purpose, High Stability and AC Line EMI Suppression MDC Series Dual In-Line, VDC, High Current. Applications

Allegro Bioprocessing Workstations. Allegro TMBioprocessing Workstations. USD 2793b. The system s support trays are made of a highthe

Fork through-beam sensors

KEPCO Will Point You In The Right Direction!

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

Transfer switch OTEC open or delayed transition

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

Thermal Coal Market Presentation to UNECE Ad Hoc Group of Experts on Coal in Sustainable Development December 7, 2004

DC/DC converters - MINI-PS DC/ 5-15DC/

ALPHA S NEXT-GENERATION UNINTERRUPTIBLE POWER SUPPLY

(typ.) (Range) ±18 330# 89 MPW MPW

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Ref No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2

UM0672 User manual. CRX14 and CR14 reference design PCB Gerber files. Introduction

Industrial Power Supplies

HELICOPTERS Service. Helicopter Maintenance Upgrades

Data Sheet P4055 Pressure Transducer

Series AM1P-Z 1 Watt DC-DC Converter

POWER kva

Features. Description. Table of Contents

Switching Power Supplies

BC-2014 ULTRA COMPACT 4-BAY SMART BATTERY CHARGER (Military Grade)

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L

Transcription:

Keysight Technologies EV1003A Hybrid-Electric/Electric Vehicle Power-Converter Test Solution RP7900 Series Regenerative Power System SD1000 Safety Disconnect Solution PA2200 Series IntegraVision Power Analyzer Solution Brochure Accelerate power-converter testing safely Only Keysight s power-converter test solution allows you to accelerate your test without having to worry about the safety of your people.

Introduction The hybrid-electric and electric vehicle (HEV/EV) market has been growing rapidly. Increasing vehicle electrification in the automotive market brings with it new challenges in design and manufacturing. Probably the most noticeable change is the addition of high-voltage, high-power batteries to a platform that is traditionally 12 volts. Hybrid electric and full electric vehicle batteries are 300 volts and higher. These high voltages bring with them additional costs and risks. Higher costs and risks for high-voltage, high-power components Purchasing EV test equipment suitable to handle this new high-voltage, high-power environment can be in the range of 4-times more expensive than that of low-power equipment (e.g. 1 kw vs. 10 kw power sources), and many times even higher. Operating expenses will also increase, and at an even greater multiple. For example, the amount of electricity consumed by a 10 kw power source is 10X that of a 1 kw power source when sourcing full power. All this power creates an enormous amount of heat that needs to be mitigated by increasing your facility s cooling capability. Moreover, you now need to comply with high-voltage safety regulations, such as NFPA 79 in the United States. Extra equipment, such as a safety disconnect system, needs to be considered. This leads again to higher cost since you need to design, implement, and support this safety system. Finally, support and maintenance plans become much more complex, especially if you are deploying these systems worldwide. Keysight s Solution Keysight is partnering with industry leaders in the HEV/EV market to help them transition their EV tests smoothly into the world of high-voltage, high-power test. Keysight has designed a solution specifically to address the safety, regulatory, and environmental issues mentioned above. This solution is the only commercial-off-the-shelf (COTS) regenerative power system with highly integrated safety features that protect your devices under test and your people. The regenerative capabilities enable the energy consumed to be put back onto the grid cleanly, saving costs from energy consumption and cooling, while not interfering with the grid. Keysight s solution and worldwide support give you the confidence to deploy high-voltage, high-power solutions to meet the fast paced, high-growth demands of the HEV/EV market. After reviewing this brochure, please do not hesitate to contact Keysight to learn more.

03 Keysight EV1003A Hybrid-Electric/Electric Vehicle Power-Converter Test Solution - Solution Brochure Key features of the EV1003A Power Converter Test Solution Deliver safe and effective testing of EV/HEV components Safeguard your people and your devices under test Handle faults and ensure output is secured (i.e., disconnected) with redundant safety disconnect system Responds rapidly by disconnecting within 15 ms after a fault occurs Includes four disconnection points (relays) with two each on the positive and negative sides Rely on sensing that ensures the grid is live before regenerating power back to the grid ( anti-islanding ) Get an extra layer of safety with control of external AC contactors to disconnect all three phases Protect your device under test with over-voltage, over-current, and over-temperature (OVP, OCP, and OT) Supports remote inhibit, which is triggered by external inputs such as contact closure or low TTL line Utilize a compact solution that serves as a power source and an electronic load, just like a battery Get sourcing and sinking (electronic load) up to 950 V, up to 40 A, and up to 10 kw Operate in two-quadrant mode as power source and regenerative electronic load Replace the capabilities of multiple power supplies with auto-ranging output Create up to 100 kw power or loading through easy parallel connection of up to 10 units More accurately emulate high-voltage, high-power battery (up to 50 Ω) with programmable resistance (model dependent) Leverage features rarely found in 10 kw power sources: list mode, best-in-class measurement accuracy Reduce footprint with compact size: up to 10 kw of sourcing and loading in 3U Compare to typical 6 kw load at 4U and typical 12 kw load at 6U Reduce costs for cooling and electricity with an eco-friendly design Count on conversion efficiency that returns more than 85% of power to the grid during regeneration Minimize interference with other electronics with clean power being returned to the grid Performs regeneration with less than 3% total harmonic distortion (typical) at full load Shrink overall energy consumption: Less heat from dissipation means less air conditioning when sinking (DC to AC) Lessens electricity use with >85% efficiency when sourcing (AC to DC) and sinking/regenerating (DC to AC)

04 Keysight EV1003A Hybrid-Electric/Electric Vehicle Power-Converter Test Solution - Solution Brochure Solution Components RP7900 Regenerative Power System The RP7900 Series Regenerative Power System is the core of the solution. It provides the battery emulation capabilities for vehicle electrification tests, such as 2-quadrant (source/sink) operation and programmable output resistance. It also provides the added benefit of regenerating >85% of power back to the grid. This is an abbreviated list of specifications and characteristics. For the full list of specifications and characteristics, please see Specifications and Characteristics section in the Keysight RP7900 Series Operating and Service Guide, literature number RP7900-90001 http://literature.cdn.keysight.com/litweb/pdf/rp7900-90901.pdf Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 C after a 30-minute warm-up period. Specifications apply at the output terminals, with the sense terminals connected to the output terminals (local sensing). Specification RP7951A/RP7961A RP7952A/RP7962A RP7953A/RP7963A DC ratings Voltage source Current source and sink Power 0 to 500 V 0 to ±20 A 5 kw 0 to 500 V 0 to ±40 A 10 kw 0 to 950 V 0 to ±20 A 10 kw Output ripple & noise 1 CV peak-to-peak 500 mv 500 mv 1000 mv Load regulation Voltage Current 30 mv 9 ma 30 mv 17 ma Voltage programming accuracy 2 0.03% + 60 mv 0.03% + 60 mv 0.03% + 120 mv Voltage measurement accuracy 2 0.03% + 80 mv 0.03% + 80 mv 0.03% + 160 mv Current programming & measurement accuracy 2 0.1% + 12 ma 0.1% + 24 ma 0.1% + 12 ma Transient response 3 Recovery time Settling band 500 μs 1.25 V 1. From 20 Hz to 20 MHz with resistive load, terminals ungrounded, or either terminal grounded 2. At 25 C ±5 C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year, see Calibration Interval 3. Time to recover to within the settling band following a step change from 50% to 100% of full load 500 μs 1.25 V 60 mv 9 ma 500 μs 2.375 V

05 Keysight EV1003A Hybrid-Electric/Electric Vehicle Power-Converter Test Solution - Solution Brochure Safety Disconnect System The safety disconnect solution was designed to work exclusively with the RP7900 Series. In less than 15 ms the safety disconnect will remove the output voltage in order safeguard your DUT and your people in response to a fault. Faults can be generated by the RP7900 or a user (emergency switch). This is an abbreviated list of characteristics. For the full list of characteristics, please see Appendix A in the Keysight RP7900 Series Operating and Service Guide, literature number RP7900-90001 http://literature.cdn.keysight.com/litweb/pdf/rp7900-90901.pdf Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing. All supplemental characteristics are typical unless otherwise noted. Characteristic Keysight SD1000A Power relay ratings 500 VDC; 60 ADC Relay life (typical) 1,000,000 cycles Regulatory compliance EMC Complies with European EMC Directive for test and measurement products Complies with Australian standard and carries C-Tick mark This ISM device complies with Canadian ICES-001 Cet appareil ISM est conforme à la norme NMB-001 du Canada Safety Complies with European Low Voltage Directive and carries the CE-marking. Conforms to US and Canadian safety regulations. Declarations of Conformity for this product may be downloaded from the Web. Go to http://regulations.corporate.keysight.com and click on Declarations of Conformity Environmental Operating environment 2.5 MHz ( 3 db) Temperature range 0 C to 55 C (Maximum continuous power available is derated at 1% of rating per degree C from 40 C to 55 C) Relative humidity 95% or less (non-condensing) Altitude Up to 2000 meters Storage temperature 30 C to 70 C Output terminal isolation No output terminal may be more than ±950 VDC from any other terminal or chassis ground. AC Input Nominal rating Single phase; 100 240 VAC input, 50-60 Hz Input Range 86 264 VAC; 47 63 Hz Power consumption 150 W Typical weight 33 lbs (15 kg)

06 Keysight EV1003A Hybrid-Electric/Electric Vehicle Power-Converter Test Solution - Solution Brochure PA2200 Series IntegraVision Power Analyzer The IntegraVision Power Analyzer makes EV test for AC and DC power measurements simple. Easily measure power on any of the vehicles power converters, such as AC-to-DC power conversion efficiency of the on-board charger. This is an abbreviated list of specifications and characteristics. For the full list of specifications and characteristics, please see the IntgraVision PA2200 Series Data Sheet, literature number 5992-0324EN http://literature.cdn.keysight.com/litweb/pdf/5992-0324en.pdf Basic accuracy (50/60 Hz) 0.05% of reading Best power accuracy (50/60 Hz) 0.1% of reading Power channels (voltage and current) PA2201A PA2203A 2 Channels 4 Channels Voltage measurement bandwidth (-3 db) 2.5 MHz (-3 db) Current measurement bandwidth (2 A or 50 A Input) 100 khz (-3 db) Current measurement bandwidth (external input) 2.5 MHz (-3 db) Maximum voltage 1000 Vrms (2000 V peak) Maximum current Direct input 2 Arms (6 A peak) or 50 Arms (100 A peak) External transducer 10 Vrms (30 V peak) Record size Maximum 1.5 M points on each waveform simultaneously Digitizing speed Maximum 5 M samples/second at 16 bits on each waveform simultaneously Display size and type 12.1- inch capacitive multi-touch/gesture enabled display Power channels (voltage and current) Voltage Connector safety Banana Plug Maximum voltage 1000 Vrms, 2000 Vpeak Input impedance 2 M Ω 12.5 pf Ranges 5 V, 10 V, 20 V, 50 V, 100 V, 200 V, 500 V, 1000 V Current Directly connected Connector Pluggable Terminal Block, Phoenix Contact PN: 1967469 Maximum current 2 Arms, 6 A peak or 50 Arms, 100 A peak Input impedance 2 A input: 60 mω + 0.10 μh 50 A input: 6 mω + 0.06 μh Ranges 2 A input: 10 ma, 20 ma, 50 ma, 100 ma, 200 ma, 500 ma, 1 A, 2 A 50 A input: 200 ma, 500 ma, 1 A, 2 A, 5 A, 10 A, 20 A, 50 External transducer Connector Isolated BNC Maximum current 10 Vrms, 30 V peak Input impedance 100 kω 100 pf Ranges 50 mv, 100 mv, 200 mv, 500 mv, 1 V, 2 V, 5 V, 10 V Crest factor 3 at full-scale (Unless in conflict with maximum input ratings) Maximum Crest Factor of 30 at 10% of full scale Current input protection Internal current shunt measurement paths are not fused. Current limit protection (fuse or breaker) and appropriate wire sizing should be provided by the user. Currents in excess of 140% of the rated rms currents may cause permanent damage to the current measurement shunts. An internal protection mechanism is provided for the 2A shunt to avoid damage due to mis-wiring, but it should not be relied upon in situations where higher than 2 Arms currents are expected. Isolation Voltage and current terminals are isolated from earth ground to 1000 V CAT II rating. Voltage is isolated from current with 1000 V CAT II rating

07 Keysight EV1003A Hybrid-Electric/Electric Vehicle Power-Converter Test Solution - Solution Brochure Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) www.keysight.com/find/ev1003a DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, September 8, 2017 5992-2283EN www.keysight.com