IMPACT TESTER BEVS 1601 User Manual

Similar documents
Wet Abrasion Scrub Tester

HA Thickness Gauge IS:2386 (part 1)- 1963

3. Operating instructions: Minor 200

Elcometer Motorised Film Applicator

Installation and Maintenance Instructions for Morin MRP Pneumatic Rack and Pinion Actuators

TQC AUTOMATIC FILM APPLICATOR

Conveyor chain catalogue

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Installation and Maintenance Instructions for Grinnell GRP Pneumatic Rack and Pinion Actuators

Assembly Instructions

Owners manual. Öhlins Superbike front fork FG 170

Operating Instruction

Draft Indian Standard Specification for Rubber Gaskets (First Revision of IS : 1984) ICS , ,

Parts Catalogue CR-CS 484 W - CR-CS 484 WQ. for model

SETTING ZERO S cont. IF THE ZERO REPEATS WITHIN +/- 1.0 LB THEN YOU ARE READY TO CHECK SPRINGS. PAGE 4 OF 9

CRC-CSC 534 W - CRC-CSC 534 WQ

Introduction. Installing the TC 2. Unpacking the TC 2

DATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW

No.809 the Center Point Business Center Dongzhong road, Guan cheng Zone, Dongguan City Tel: Fax:

CAUTION. Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.

CRC-CSC 534 WS - CRC-CSC 534 WSQ

CRC-CSC 534 WS - CRC-CSC 534 WSQ

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

Lock Junior Office Classic 48 50

HANATEK FRICTION TESTER. MODEL 6010 (Obsolete) INSTRUCTION MANUAL. Replaced by:

Technical Data for Metric Thickness Gauges Page Model Reading Range Depth of jaw Lifting Contact points Contact points

Swaging Machine Type H32B4

Laboratory Vane Apparatus SL800. Impact Test Equipment Ltd & User Guide. User Guide

Cable current transformers for indoor applications. Product overview. Cable current transformers. for indoor applications.

Shawal CGC Calibration Profile

SCROLL SAW SS-10 PART NO DATE:

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

«CHARPY» Computerized Pendulum IMPACT TESTERS

Instruction Manual May milltronics MWL WEIGHT LIFTER

CRL-CSL 484 WS - CRL-CSL 484 WSQ

Extrusion Plastomelter -Standard Operating Procedure [Updated June 30, 2015]

ORIGA SYSTEM PLUS Guides, Brakes and Valves for Modular Linear Drive Systems OSP Appendix to the Operating Instructions

Spareparts COMBI 53 SQ. Model Year 2012

OPERATION AND MAINTENANCE MANUAL. PennEngineering 5190 OLD EASTON ROAD DANBORO, PENNSYLVANIA

BUCKEYE LEGACY POLISHED CONCRETE ENHANCER & PROTECTANT MODEL SPECIFICATION

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

OPERATING MANUAL. Black Bruin Hydraulic Rotators

NUTS, WASHERS, SCREWS & STUDS WDS SECTION 8 - NUTS, WASHERS, SCREWS & STUDS

CL2-B INSTRUCTION BOOKLET CONTENTS

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

PARTNERIllustrated Parts List CD

Elcometer 415. Coating Thickness Gauge. Operating Instructions

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

/ CABLE TIES & WIRE FASTENERS /

Hydraulic hand-punching tool HS-6. Art convincing solutions

DB4604 GMR-SD and GMR40-SD Disc Brake Caliper - Spring Applied, Air Released

Small Tool Instruments and Data Management

MWL Milltronics Weight Lifter. Instruction Manual June 2001

Service Tools. Service and Repair Manual Model 900/950/990 ITEM PART NO. DESCRIPTION ITEM PART NO. DESCRIPTION ITEM PART NO.

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

GMR-S and GMR40-S Disc Brake Caliper - Spring Applied, Air Released

UNIVERSAL CALIBRATING MACHINES

ceramus HiClass in dispensing.

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL

About TekMarine. Disclaimer. Copyright

Plain Ended Welding Fittings BS 4825 Part 2

Registered in England number Wherever in the world quality matters. Slipperiness Resistance testing (ISO /DIN 51130/DIN 51097)

ROUGHSCAN SURFACE ROUGHNESS TESTER OPERATIONAL MANUAL

SKF Grease Test Rigs

CERANI 35mm ROAD RACING FORKS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR T40 Mk. 2 DISC BRAKE CALIPER M1492

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

SV60 Safety Valve Replacement Parts Fitting Instructions

Twin-Column Motorized Tension, Compression & Cycle Tester (M5KNE & M10KNE) User s Manual

DieMax XL TM Maximum Life Springs

The economical machinery mounting solution

LPCB LPS 1175 APPROVED PRODUCTS

Elcometer 506 Pull- Off Adhesion Gauge. elcometer.com 1

Rotary Valve Maxflo + 60 and 80 Opening type NT

VBK 2596/12E/RSF. Thickness and Width Gauge for Strip and Profile. Operating- & Service Instructions. (with lateral guide rollers)

For reproducible measurements

Small Tool Instruments and Data Management

Mettler Analytical Balance AE240 Dual Range Balance

Parts Catalogue TU 504 TR-R 4S. for model

ENGINE - GLOW PLUGS. Innovation is our mission!

Operating Manual. LKHSP Self-Priming Centrifugal Pump IM70818-GB

Cylinders. Hinges. Bolts

F 427/3 Strength Tester for Yarns, Hanks and Fabrics

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

SS-9A PART NO Revised:

Elcometer Payne Permeability Cup. Operating Instructions

Enigma Travel Chair and Lightweight Aluminium Wheelchair Owner s Handbook

Easy to clean ultra plane glass bed Easy to clean ultra plane glass bed with models AB3110 and AB3120

ETRTO proposal for UN R30 & 64 amendments

Operator s Manual. GreenTek Ltd Rudgate Walton Leeds LS23 7AU UK

PAD RETAINING AND SPRING APPLICATION PAGE

ROTOFIX 46/46 H Benchtop centrifuges classic/heated

TERMINATOR User Manual

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar

USER INSTRUCTIONS FOR OPERATION & MAINTENANCE 4068 Pneuma c / Hydraulic Installa on Tool

Technical Report. 10 th Round Robin Test for Multi-Capillary Pressure Drop Calibration Standards (2014)

Transcription:

IMPACT TESTER BEVS 1601 User Manual Version 201412 This manual shall be read carefully before starting. Directions included in this operation manual shall be strictly followed. PAGE 1

1 Company Profile Content 2 Product Introduction 3 Important Safety Instructions 4 Features 5 Installation 6 Calibrating The Impact Tester 6.1 Impacter 6.2 Anvil 6.3 Scale Zero 7 How To Make Measurements 7.1 Test Panels 7.2 Environment 7.3 Operation 8 Routine Maintenance 9 Spares List 10 Specification PAGE 2

1 Company Profile BEVS Industrial Co.,Ltd. is a leading manufacturer that specializes in coatings, ink, painting, resin testing instruments and laboratory whole solution. We offer the complete and unique products in this field to meet customer's challenging demands of today and tomorrow, the products are complied with the standards of ISO, ASTM, DIN, BS, EN etc. With strong supports and hard work by lots of end-users and worldwide agents, BEVS become more and more famous in the world and provides more competitive values for our customers. PAGE 3

2 Product Introduction Many surface coatings are subject to the risk of damage by impact. Falling-weight testers (Tubular Impact Testers) allow reproducible conditions of impact to be defined. The BEVS1601/2 allows pass/fail limits to be established and a classification of the coating to be achieved. The BEVS1601/2 Tubular Impact Tester is designed to conform to ISO 6272 & ASTM D 2794 Falling Weight Test. We advise customers to obtain and maintain an up to date copy of the relative specification. Main features: Falling weight (Impacter/indenter) BEVS1601/2 is fitted with 4lb Identer diameter 0.625 (15.9mm) Die (Anvil) diameter 0.642 (16.3mm) Drop height Sample held by two spring clips Facility to add extra weight 3 Important Safety Instructions 3.1 Ensure instrument is bolted down 3.2 When using instrument, use one hand to release impacter and keep other hand away. Do not hold on to test sample. 3.3 Keep clear of lifting knob of falling weight (Impacted). 3.4 When instrument is not in use, lower impacted to bottom of tube. 4 Features This instrument consists of a graduated vertical tube mounted into a solid base. This tube acts as a guide for an impacting weight of pre-determined mass. The height from which this falls is variable. By using the locking collar, exactly the same force of impact can be produced for each test. PAGE 4

5 Installation 5.1 See Point 11, Working Environment. 5.2 Remove all packing material. 5.3 Bolt the instrument on to a firm level surface i.e. concrete, steel or stone, using two 8mm bolts by 40mm long minimum. A workbench is not solid enough! Fixing centres for bolts is 227mm to be at least 150mm from front of mounting surface and/or 200mm from the back of mounting surface. 5.4 Check tube is vertical. If necessary use steel shim under feet of instrument to set tube to vertical. 6 Calibrating The Impact Tester 6.1 Impacter Remove falling weight from instrument by first removing release mechanism (taking care not to lose the two small clamp pads situated between clamp screws and tube).lift falling weight to top of tube, whilst holding falling weight at top of tube unscrew lifting knob rod. The falling weight may now be removed by lifting it out of the tube. Weigh the falling weight together with its knob and handle. The weight is to be 4lb ±0.01lb for BEVS1601/2. Remove impacter from guide bush by lifting out and Inspect the 5/8 ball for any damage. Assemble falling weight, release mechanism and impacter back into the instrument using reverse procedure to dismantling, ensure handle is screwed securely home after carrying out 6.2. 6.2 Anvil Whilst falling weight and anvil are removed (see 6.1) remove anvil from instrument by lifting from base if instrument. Inspect the anvil for damage and corrosion. Hole in anvil to be 16.3 ±0.2mm dia. Radius on top edge of hole to be R3±0.5mm Replace anvil in the instrument. 6.3 Scale Zero Place a 1.2mm thick flat test piece on anvil and carefully lower impacter and then weight onto the PAGE 5

test piece. Lower the release mechanism and turn release ring handle so as to capture the weight. Lift release mechanism until resistance of the weight is felt, then tighten the two knurled clamp screws. The datum face of the release mechanism is the bottom face and this should now be in line with the zero line on the scale. 7 How To Make Measurements 7.1 Test Panels Ensure panels conform to ISO 1514 Coating conforms to ISO 2808 Drying has been carried out to your requirements. 7.2 Environment Temperature is 23±2 C Relative humidity is 50±5% Test panel has acclimatised for at least 16 hours. 7.3 Operation 7.3.1 Determine if coated face is to be up or down or both. 7.3.2 Set height for impacter to drop, by loosening the two small knurled clamp screws either side of the release mechanism mounted on the tube, and slide to the required height (the lower face of the mechanism is the datum face), then tighten the two screws. 7.3.3 Raise the falling weight using the falling weight lifting knob, rotate the release ring handle to capture the falling weight at the required height. 7.3.4 Place test sample panel in position. 7.3.5 Release the falling weight by rotating the release ring handle until the falling weight drops. Keep clear of falling handle and do not hold onto test piece. 7.3.6 Raise the falling weight as in 6.3.3 and remove the test panel for inspection. PAGE 6

8 Routine Maintenance 8.1 When instrument is not in use keep anvil lightly oiled to prevent corrosion. 8.2 Keep instrument clean. 8.3 Check fixing bolts are still secure. 8.4 Check falling weight lifting knob and handle are secure. 8.5 Check clamp pads are still serviceable. PAGE 7

9 Spares List Impacter 5/8 Anvil 16.3mm Falling weight 2lb Falling weight 4lb Additonal 1lb weight Additional 1kg weight Weight lifting handle Knob (lifting handle) Thumbscrew (2 per) Clamp pad (2 per) 10 Specification physical dimensions Weight (instrument) : 253mm wide x 253mm deep x 1131mm high for BEVS1601/2 8.5 Kg Associated Specifications: BS6496 ASTM D 2794 Falling Weight: 4lb±0.01lb 806/40(Additional weights can be mounted onto the falling weight) Impacter : Die(Anvil): Dropping Height: 5/8 ball Hole diameter 16.3±0.2mm with 3 radius on top edge Variable from zero to 40 on BEVS1601/2 Sample Clamp: Held lightly by two spring clamps 11 Working Environment: This instrument has been designed for indoor use, in a temperature range of 23±2 C and relative humidity of 50±5%. PAGE 8