COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - SUSPENDED

Similar documents
COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - RECESSED MOUNT

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices.

COOLEDGE LINE INSTALLATION INSTRUCTIONS

The entire TILE Exterior system including light sheets, connectors, cables, and LED power supplies is rated for wet location

1 TILE Interior SPECIFICATION

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

COOLEDGE TILE TUNABLE WHITE - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

COOLEDGE TILE INTERIOR - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

Clutch Operated FlexShade NEXD Window shade with heavy duty clutch and 3 hardware profile. Cassette option.

Inde-Pendants Family. 32L Cylinder with Ring Chicago Plenum Ceiling Types. Document No

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

INSTALLATION MOTORIZED COUPLED SHADE

INSTALLATION MANUAL. Recessed In-Ceiling Motorized Projection Screen

SCION xa / xb FUEL LID APPLIQUÉ Section I Installation Preparation

Ground Effects, P/N: (V6), (V8)

Installation Instructions: Eco Linear High Bay

Rollstar Shade Installation Instructions

SCION xb DASH APPLIQUÉ Section I Installation Preparation

Perimeter Lighting. High Performance. Perimeter Slot (HP-WS) & Wall Grazer (HP-WG)

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

Rail Family. Mountings. Distributions

COOLEDGE TILE EXTERIOR - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

TOYOTA 4-RUNNER TOWING HITCH Preparation

Trackstar Motorized Folding Shade Installation Instructions

HP-2 / HP-6 Direct Installation Instructions Overview

Installation Instructions Roller Shades. 451 N. Cota St, Corona, CA

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

General Installation Instructions LED

Installation Instructions

PLEASE READ THESE INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

Type: Quantity: Project:

Estimated Cable Fill Width in (mm) in 2 mm 2.30 OD. Cable Fill Area

INSTALLATION INSTRUCTIONS

Top Down Rollstar Shade Installation Instructions

Installation Manual Infinity LED Light

CFP-LED Contractor Select Flat Panel. Installation Instructions

INSTALLATION INSTRUCTIONS

Hi-tech Bluetooth Mirror Introduction

INSTALLATION INSTRUCTIONS

Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions

Windshields and Bonded Glass. WARNING: Use rubber gloves and any appropriate breathing apparatus as recommended by the manufacturer of the kit.

Horizontal Shadings. Continuous Cord Loop Beaded Chain Loop Cordless Lift. Installation & Operating Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Operation Care

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

Photo: Rix Ryan. Cloud

Wheel Arch Trim Set. Installation Manual. This section covers installation of the wheel arch trim set.

HANGING LANTERN ITEM # MODEL #CP199MBK. Français p. 9. Español p. 17 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

LHBC Commercial-Grade High or Low Bay Luminaire

Installation instructions for the LUX LED-GYM WAVE

NOVO LIGHTED MIRROR. Installation Instructions

INSTALLATION INSTRUCTIONS

3M Closure System 2-Type Cover (505)

Aggressive Chin Spoiler CDC#

INSTALLATION INSTRUCTIONS

English. Fitting Instructions: Bonneville and Bonneville T100 A , A and A of 9. Parts Supplied:

440/880LB ELECTRIC HOIST STF-4488EH

Description. Material. LED Chip. Mounting. Max Length. Environment. Certifications. Warranty. Dimming

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions

WHISPERWAVE Panels, Baffles, Ceiling Clouds and Awnings Installation Instructions

Exhaust System Installation Turbo Downpipe Audi MKII TT-RS 2.5T CD100028

CIRCULATOR 1400 MDCCIRC OPERATING MANUAL

This is the Unpacking Guide for the Optibike Pioneer Allroad electric bicycle. The Guide provides information required to remove the Allroad from the

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

Installation Instructions

TOYOTA FJ CRUISER 2007 AUXILIARY LIGHTS Preparation

Custom LitePad Handling & Mounting Guide

I. General Safety Precautions

LumaFilm Light Emitter Installation Instructions

ASX / OUTLANDER SPORT SHIFT KNOB MZ525507EX INSTALLATION AND HANDLING INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Installation Instructions Roller Shades. 451 N. Cota St, Corona, CA

Fastback Top Installation Instructions and Owner s Manual

Skyline 4 Fascia Fabrication & Installation Instructions

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

INSTALLATION INSTRUCTIONS

Catalog # Project. Comments. Prepared by. 6.4" [163 mm] Lumen Package Nominal per 4 section

Lineals Security Mirrors to 14-4 Mirror Clips Mirror Rosettes & Accessories to 14-6 Mirror Plates...

Sky FactoryTM toll free

TOYOTA TUNDRA BIG BRAKE KIT Section I - Installation Preparation

Standard Roller Shades

LED Wall Sconce. Offered with a frosted lens, these wall luminaires provide a high quality diffuse light due to their high CRI of more than 90.

L-SERIES CLUTCHES L-SERIES CLUTCHES. Getting Started INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

31065 INSTALLATION INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Continuous Cord Loop Designer Series Roller Shades

Serena Remote Controlled Shades

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Installation Operation Care

LUXAFLEX DUETTE Shades with Hard-Wired Motorisation. Installation Operation Care

Installation Instructions. Ventvisor Deflector

CLARA CLA SUSPENDED, WALL, SURFACE

ATV WINCH. Thank you for purchasing a

Service Bulletin DIS185SSI4F Air Compressor Multiple Component Update

Transcription:

5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - SUSPENDED INSTALLATION GUIDE Cooledge FABRICated Luminaires are a simple, out-of-the-box way to incorporate the unique look and feel of a stretch fabric ceiling into your space. Bring the feeling of the outdoors inside: fill an open concept space with clouds of light that also absorb sound to deliver an environment that truly caters to people. Suspended luminaires deliver immersive illumination and noise reduction for: Showrooms Lobbies Open-plan Offices Shop-in-shop Retail Features Cooledge s unique Infinity Edge design for uniform illumination from edge to edge. 5 5 Year Limited Warranty: Parts and workmanship Cooledge Lighting Inc. 110-13551 Commerce Parkway Richmond, BC V6V 2L1 Canada O +1 604 273 2665 F +1 604 273 2660 T +1 844 455 4448 W cooledgelighting.com Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company s continuing product improvement program. EXT-0076-R00-110218 (LTR) 1/18

1. TOOLS! WARNING: Wear clean cotton or latex gloves when handling Cooledge FABRICated Luminaires. Do not remove the plastic protective film until the point noted in this install guide. Gloves Cable Cutters Measuring Tape Saw Horses Level 4mm Hex Key Only required for Threaded rod mounting: 2x wrenches CAUTION: Observe precautions for handling electrostatic sensitive devices.! CAUTION: Use appropriate Personal Protective Equipment (PPE) to ensure safety at work. EXT-0076-R00-110218 (LTR) 2/18

2. INSTALLATION PROCEDURE (AIRCRAFT CABLE SUSPENDED MOUNT) 2.1. UNPACK LUMINAIRE AND PLACE FACE DOWN ON SAW HORSES AT CORNERS NOTE: Leave protective plastic film attached 2.2. ATTACH POWER AND CONTROL TRAY(S) TO STIFFENERS NOTE: Trays may be mounted remotely. In this case, the DC power connections should be made to the Luminaire (section 2.3) with a suitable length of cable. Refer to EXT-0071 Cooledge Lighting Control Module User Guide for setting up the control module. NOTE: Power Supply and Control Module may vary NOTE: Ensure T-nuts rotate fully inside channel to tighten correctly EXT-0076-R00-110218 (LTR) 3/18

2.3. POWER AND CONTROL TRAY TO LUMINAIRE NOTE: The power and control tray type will vary depending on region, luminaire size, and control protocol. 1-CHANNEL Control Module Wiring ors (CE compliant systems only) To power Power supply Supply To To Controls { 0V Starter Cable DIM (+) DIM (-) RED (+) BLACK (-) To Luminaire Static Color Temperature (SCT) Systems 2.6 To Luminaire (1-4 cables) 1.4 To power supply To Controls { CH1 CH2 CH3 0V Starter Cable CH4 RED (+) 8.7 DIM (+) DIM (-) BLACK (-) Control Module PSU : 200/400W Tunable (TNW) and Dim-to-Warm (DTW) systems 2.6 To power supply To Controls 1.4 To Luminaire (1 or 2 cables) { SYS 1 3600 0V Starter Cable SYS 3400 2 8.7 DIM (+) DIM (-) RED (+) BLACK (-) CCT (K) 3200 Control Module 3000 2800 2600 2400 2200 0% 10% 20% 30% 40% 50% 60% 70% Dim Level PSU 200W EXT-0076-R00-110218 (LTR) 4/18

2.4.ESTABLISH THE REQUIRED POSITIONS FOR SUSPENSION CABLES Either measure between the suspension points or refer to TABLE 1, PAGE 17. NOTE: Smaller sizes require four suspension cables; larger sizes require six cables (see TABLE 1, PAGE 17). 2.5. ATTACH CABLES TO CEILING ANCHOR POINTS AT REQUIRED POSITIONS EXT-0076-R00-110218 (LTR) 5/18

2.6. ATTACH CABLES TO HANGER BRACKETS WITH GRIPPERS 2.7. RAISE LUMINAIRE TO REQUIRED HEIGHT EXT-0076-R00-110218 (LTR) 6/18

2.8. LEVEL THE LUMINAIRE 2.9. REMOVE THE PROTECTIVE PLASIC WRAPPING Ensure you wear gloves from this point forward to prevent marks on the fabric. 2.10. ATTACH THE TRIM (FASCIA) EXT-0076-R00-110218 (LTR) 7/18

Remove adhesive liner from corner trim cover and apply. Make sure the bottom flange of the cover is touching the bottom of the trim. Remove the adhesive liner and apply to the trim. Make sure the bottom flange is touching the bottom of the trim. 2.11. THE ELECTRICAL POWER The electrical power connections should be made by a qualified electrician in accordance with all national and local electrical and construction codes. Refer to EXT-0071 Cooledge Lighting Control Module User Guide for setting up the control module. AC to Power Supply NOTE: Power Supply and Control Module may vary EXT-0076-R00-110218 (LTR) 8/18

3. INSTALLATION PROCEDURE: THREADED ROD MOUNTING 3.1. UNPACK LUMINAIRE AND PLACE FACE DOWN ON SAW HORSES AT CORNERS NOTE: Leave protective plastic film attached 3.2. ATTACH POWER AND CONTROL TRAY(S) TO STIFFENERS NOTE: Trays may be mounted remotely. In this case, the DC power connections should be made to the Luminaire (section 2.3) with a suitable length of cable. Refer to EXT-0071 Cooledge Lighting Control Module User Guide for setting up the control module. AC to Power Supply NOTE: Power Supply and Control Module may vary NOTE: Ensure T-nuts rotate fully inside channel to tighten correctly EXT-0076-R00-110218 (LTR) 9/18

3.3. ATTACH MOUNTING BRACKETS NOTE: Smaller sizes require four brackets; larger sizes require six or eight brackets (see TABLE 2, PAGE 18). NOTE: Ensure T-nuts rotate fully inside channel to tighten correctly 3.4. ESTABLISH THE REQUIRED POSITIONS FOR THREADED RODS Either measure between the suspension points or refer to TABLE 2, PAGE 18. EXT-0076-R00-110218 (LTR) 10/18

3.5. MOUNT THREADED RODS TO CEILING STRUCTURE AT REQUIRED POSITIONS Note: Threaded rods and associated hardware are not supplied by Cooledge. Recommended size of threaded rod is 3/8-16 or M10. The lower end of the threaded rods must be 4.5 to 6.25 [115mm to 160mm] above the desired level of the fabric surface of the luminaire. 2 9/16" [65mm] MAX 4.5-6.25" [115-160mm] FROM FINAL HEIGHT OF FRONT OF LUMINAIRE Install one nut on each rod at the desired height. 3.6. ATTACH FOUR CABLES TO THE CEILING ALONGSIDE THE THREADED RODS NOTE: Cables are used to assist in installation but may be left in place if desired. EXT-0076-R00-110218 (LTR) 11/18

3.7. ATTACH CABLES TO HANGER BRACKETS WITH GRIPPERS 3.8. RAISE LUMINAIRE TO JUST BELOW THREADED RODS *Example with cable gripper. EXT-0076-R00-110218 (LTR) 12/18

3.9. ATTACH THE LUMINAIRE TO THE THREADED RODS 3.10. LEVEL THE LUMINAIRE If cables are to be left in place, tighten to remove slack. Otherwise, remove cables. EXT-0076-R00-110218 (LTR) 13/18

3.11. REMOVE THE PROTECTIVE PLASIC WRAPPING Ensure you wear gloves from this point forward to prevent marks on the fabric. 3.12. ATTACH THE TRIM (FASCIA) Remove adhesive liner from corner trim cover and apply. Make sure the bottom flange of the cover is touching the bottom of the trim. Remove the adhesive liner and apply to the trim. Make sure the bottom flange is touching the bottom of the trim. EXT-0076-R00-110218 (LTR) 14/18

3.13. THE ELECTRICAL POWER The electrical power connections should be made by a qualified electrician in accordance with all national and local electrical and construction codes. Refer to EXT-0071 Cooledge Lighting Control Module User Guide for setting up the control module. AC to Power Supply NOTE: Power Supply and Control Modules may vary 3.14. POWER AND CONTROL TRAY TO LUMINAIRE 1-CHANNEL Control Module Wiring ors (CE compliant systems only) To power Power supply Supply To To Controls { 0V Starter Cable DIM (+) DIM (-) RED (+) BLACK (-) To Luminaire EXT-0076-R00-110218 (LTR) 15/18

Static Color Temperature (SCT) Systems 2.6 1.4 To power supply To Controls To Luminaire (1-4 cables) { CH1 CH2 CH3 0V Starter Cable CH4 RED (+) 8.7 DIM (+) DIM (-) BLACK (-) Control Module PSU : 200/400W Tunable (TNW) and Dim-to-Warm (DTW) systems 2.6 To power supply To Controls 1.4 To Luminaire (1 or 2 cables) { SYS 1 3600 0V Starter Cable SYS 3400 2 8.7 DIM (+) DIM (-) RED (+) BLACK (-) CCT (K) 3200 Control Module 3000 2800 2600 2400 2200 0% 10% 20% 30% 40% 50% 60% 70% Dim Level PSU 200W 4. CARE AND MAINTENANCE Do not use any liquids to clean the fabric they will cause permanent staining. Clean the fabric in any of the following ways: Brush gently with a clean, soft cloth. Vacuum with a clean brush-tip vacuum nozzle. Blow with compressed air. Use an adhesive lint-roller (recommended to test a small area in a corner in case roller leaves residue). Clean trim with a clean, soft cloth. EXT-0076-R00-110218 (LTR) 16/18

5. APPENDIX POSITIONS OF SUSPENSION POINTS 5.1. CABLE ATTACHMENT POINTS x x C L y C L C L y C L TABLE 1 NOMINAL SIZE # SUSPENSION POINTS DIM X DIM Y 4 X 4 (1200mm X 1200mm) 4 20 5/8 [525mm] 21 5/8 [550mm] 4 X 6 (1200mm X 1800mm) 4 21 5/8 [550mm] 21 5/8 [550mm] 4 X 8 (1200mm X 2400mm) 4 25 13/16 [655mm] 21 5/8 [550mm] 4 X 10 (1200mm X 3000mm) 4 38 [965mm] 24 [610mm] 6 X 6 (1800mm X 1800mm) 4 16 7/16 [415mm] 35 13/16 [910mm] 6 X 8 (1800mm X 2400mm) 4 28 3/16 [715mm] 35 13/16 [910mm] 6 X 9 (1800mm X 2700mm) 4 32 15/16 [835mm] 35 13/16 [910mm] EXT-0076-R00-110218 (LTR) 17/18

5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY 5.2. THREADED ROD ATTACHMENT POINTS TABLE 2 NOMINAL SIZE # THREADED RODS DIM X1 DIM X2 DIM Y 4 X 4 (1200mm X 1200mm) 4 13 ¾ [350mm] N/A 20 9/16 [520mm] 4 X 6 (1200mm X 1800mm) 6 On center 32 ¼ [820mm] 20 9/16 [520mm] 4 X 8 (1200mm X 2400mm) 6 On center 39 3/16 [995mm] 20 9/16 [520mm] 4 X 10 (1200mm X 3000mm) 8 23 1/2 [595mm] 51 [1295mm] 22 15/16 [580mm] 6 X 6 (1800mm X 1800mm) 6 On center 29 13/16 [755mm] 34 ¾ [880mm] 6 X 8 (1800mm X 2400mm) 8 14 [355mm] 41 5/8 [1055mm] 34 ¾ [880mm] 6 X 9 (1800mm X 2700mm) 8 12 7/16 [315mm] 44 3/4 [820mm] 34 ¾ [880mm] 5 5 Year Limited Warranty: Parts and workmanship Cooledge Lighting Inc. 110-13551 Commerce Parkway Richmond, BC V6V 2L1 Canada O +1 604 273 2665 F +1 604 273 2660 T +1 844 455 4448 W cooledgelighting.com Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company s continuing product improvement program. EXT-0076-R00-110218 (LTR) 18/18