Verifying the accuracy of involute gear measuring machines R.C. Frazer and J. Hu Design Unit, Stephenson Building, University ofnewcastle upon Tyne,

Similar documents
Set your Mobile Phones to Silent Respect your colleagues no private conversations Be on time

UNDERSTANDING CMM SPECIFICATIONS AND CALIBRATION METHODS

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

Lecture (7) on. Gear Measurement. By Dr. Emad M. Saad. Industrial Engineering Dept. Faculty of Engineering. Fayoum University.

Standard Calibration Certificate

Quindos the Ultimate Software package for Gears, Gear Tools and other Special Applications

A PORTABLE SYSTEM FOR THE CALIBRATIONOF TRANSDUCERS AND TORQUE WRENCHES: THE CALIBRATION BELL

Standard Calibration Certificate

Part VII: Gear Systems: Analysis

Gear Measurement. Lecture (7) Mechanical Measurements

ANALYSIS OF SURFACE CONTACT STRESS FOR A SPUR GEAR OF MATERIAL STEEL 15NI2CR1MO28

QUINDOS. the Analysis tool for Metrology

Catalog Q Conversion For those wishing to ease themselves into working with metric gears

Worm gear meshing stiffness calculations based on experiments

Gear Tooth Geometry - This is determined primarily by pitch, depth and pressure angle

USV Ultra Shear Viscometer

Industry 4.0 Is Unthinkable Without Calibration!

ISO Acceptance and re-verification tests for Coordinate Measuring Machines. a brief introduction

A New Device to Measure Instantaneous Swept Volume of Reciprocating Machines/Compressors

AN OPTIMAL PROFILE AND LEAD MODIFICATION IN CYLINDRICAL GEAR TOOTH BY REDUCING THE LOAD DISTRIBUTION FACTOR

IMGC-CNR Activities to Improve the Force Chain in Italy. C. Ferrero and C. Marinari Istituto di Metrologia G. Colonnetti (IMGC-CNR) Torino - ITALY

Introduction. Kinematics and Dynamics of Machines. Involute profile. 7. Gears

Transmission Error in Screw Compressor Rotors

CH#13 Gears-General. Drive and Driven Gears 3/13/2018

KISSsoft 03/2013 Tutorial 15

Certificate of Accreditation

KISSsoft 03/2017 Tutorial 15

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

ANALYSIS OF SPUR GEAR GEOMETRY AND STRENGTH WITH KISSSOFT SOFTWARE

o f Tip Relief on Transmission

Draft Project Deliverables: Policy Implications and Technical Basis

Design of Helical Gear and Analysis on Gear Tooth

National comparison on verification of fuel dispensers

Bevel Gears. Fig.(1) Bevel gears

STRAIGHT SPUR GEARS and RACKS

Determination and improvement of bevel gear efficiency by means of loaded TCA

using a low force 3D touch probe

CHAPTER 5 PREVENTION OF TOOTH DAMAGE IN HELICAL GEAR BY PROFILE MODIFICATION

ISO INTERNATIONAL STANDARD

KISSsoft Tutorial 012: Sizing of a fine pitch Planetary Gear set. 1 Task. 2 Starting KISSsoft

ISO INTERNATIONAL STANDARD. Straight cylindrical involute splines Metric module, side fit Part 2: Dimensions

GREENER SHIPPING SUMMIT 2017

Measuring Threaded Holes

Metrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005

Legal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice

PRODUCTS AND SERVICES 2017

GMS 32. Double flank testing machine for gears

Research in hydraulic brake components and operational factors influencing the hysteresis losses

Design & Development of Precision Plastic Gear Transmissions

Optimization of Scissor-jack-Damper s Parameters and Performance under the Constrain of Human Comfort

SPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101

GEAR NOISE REDUCTION BY NEW APPROACHES IN GEAR FINISHING PROCESSES

Brake caliper machining: improve process control and reduce inspection costs

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

ANALITICAL METHOD TO CALCULATE THE UNKNOWN GEOMETRY OF CYLINDRICAL GEARS

EXPERIMENTAL STUDY OF DYNAMIC THERMAL BEHAVIOUR OF AN 11 KV DISTRIBUTION TRANSFORMER

TRANSLATION (OR LINEAR)

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

ANALYSIS OF GEAR QUALITY CRITERIA AND PERFORMANCE OF CURVED FACE WIDTH SPUR GEARS

Metallic materials Rockwell hardness test. Part 2: Verification and calibration of testing machines and indenters

Product Loss During Retail Motor Fuel Dispenser Inspection

Technical Publications Catalog. April 2014

ME6601 DESIGN OF TRANSMISSION SYSTEMS

11. GEAR TRANSMISSIONS

CASE STUDY OF ASSEMBLY ERRORS INFLUENCE ON STRESS DISTRIBUTION IN SPUR GEAR TRAIN

UNIT -I. Ans: They are specified by the no. of strands & the no. of wires in each strand.

INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION

Technical Papers supporting SAP 2009

CHECK AND CALIBRATION PROCEDURES FOR FATIGUE TEST BENCHES OF WHEEL

Technical Publications Catalog. October 2016

2 HEXAGON MANUFACTURING INTELLIGENCE HexagonMI.com

INVOLUTE SPIRAL FACE COUPLINGS AND GEARS: DESIGN APPROACH AND MANUFACTURING TECHNIQUE

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

REDUCTION OF IDLE-HUNTING IN DIESEL FUEL INJECTION PUMP

Gearheads H-51. Gearheads for AC Motors H-51

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

Typical Stress & Deflection Analysis of Spur Gear in Spur Gear Assembly

Spur gearing, Helical gearing [mm/iso] Pinion Gear ii Project information? i Calculation without errors.

LVC-100/LVG-100. CNC Bevel Gear Cutting Machine CNC Bevel Gear Grinding Machine.

Certificate of Accreditation

Technical Publications Catalog. October 2015

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring

JJG Translated English of Chinese Standard: JJG

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

SMOOTHING ANALYSIS OF PLS STORAGE RING MAGNET ALIGNMENT

Selecting Weights and Certificates

Chapter 3. Transmission Components

Small Tool Instruments and Data Management

MODULE- 5 : INTRODUCTION TO HYDROSTATIC UNITS (PUMPS AND MOTORS)

Measurement methods for skid resistance of road surfaces

Update on Fast SAR Techniques and IEC V3. Matthias MEIER Chairman of Advisory Board, ART-Fi 10 April 2014

LAPPING OR GRINDING? WHICH TECHNOLOGY IS THE RIGHT CHOICE IN THE AGE OF INDUSTRY 4.0?

ISO INTERNATIONAL STANDARD

50 g 50 e g ars e o ars lut o i lut on o s n.c s o.c m o

Creative Motion Control Planetary Roller Screws

ISO INTERNATIONAL STANDARD

UK Weighing Federation Technical Articles

PERFORMANCE OF THE NEW PRIMARY TORQUE STANDARD MACHINE OF INMETRO, BRAZIL

More Detail about Helical & Bevel Helical Reduction Gear Boxes.

User Manual. Aarhus University School of Engineering. Windtunnel Balance

Transcription:

Verifying the accuracy of involute gear measuring machines R.C. Frazer and J. Hu Design Unit, Stephenson Building, University ofnewcastle upon Tyne, Abstract This paper describes the most common methods of inspecting gears and the measuring machines used. Methods of verifying the accuracy of gear measuring machines are discussed, with particular reference to EGA codes of practice. Some example results are presented. 1. Background Gears are important mechanical components found in 90% of mechanical transmissions. They have a complex geometry and transmit high power, often at high speed. They must be made very accurately if their load carrying capacity and noise levels are to be acceptable in service. Nearly all parallel axis gears are involute spur or helical gears. Involute gears may be inspected by a number of methods, but the most commonly used is to check the individual error parameters. That is lead (tooth alignment) errors, profile (involute profile) errors, and pitch (tooth spacing) errors. It is normal practice to check 4 equally spaced teeth for lead and profile accuracy and check all teeth for pitch accuracy. Gear standards [1] specify the recommended accuracy requirements for these parameters. Table 1 shows the typical accuracy requirements for a gear from an automotive gearbox. These tolerances are tight and demand high standards of metrology. A commonly used rule-of-thumb is that the inspection process should have a measurement uncertainty of approximately 10% of the tolerance being measured. Table 1 shows that these are exceptionally tight limits for a gear inspection machine and in practice, 20% to 30% is the best that may be achieved. There are many types of machine used to inspect gears these include traditional mechanical machines and CNC machines, examples of which are shown in Fig. 1. CMMs with gear measurement software are available but they are not so commonly used by gear manufacturers because they are generally considered to be too slow. The dedicated gear measuring machines generate the theoretical

294 Laser Metrology and Machine Performance shape of the involute and helix and use a probe to scan the surface of the tooth at a specified measuring position. Machines will measure a large size range of gears (some up to 2.6m diameter) with different geometries, different weights, at different positions within the measuring volume. Verifying the accuracy of these machines can be a complex, time consuming activity, but obviously very necessary if gear failures caused by measurement errors are to be avoided. 2. Introduction and Methodology It is not possible to fully 'calibrate' a complex measuring instrument such as a gear measuring machine or a CMM. The best that may be achieved, given reasonable time constraints, is that the function of the machine and its accuracy is verified at a number of settings through its measuring range. A series of Codes of Practice for traceably verifying the accuracy of a gear measuring machine have been issued by the British Gear Association (EGA). These were prepared by Design Unit, who run the UK National Gear Metrology Laboratory, and members of the EGA Technical Committee. They are not standards as such, but are technical documents which gear manufacturers are able to adopt and follow if they wish. Companies who are ISO 9000 accredited will satisfy the requirement that key measurements are traceably verified to National Standards by following these codes. The methodology adopted by the codes involves a combination of functional measurements on traceably calibrated artefacts and the direct verification of elements of the machine which are known to be common sources of error and are vulnerable to damage during use. The test results are analysed to determine the measurement uncertainty of the machine within a pre-defined measuring volume. Once this has been established, the operator of the machine must frequently check the performance of the machine by measuring a traceably calibrated gear artefact. This two stage approach minimises the amount of time required to carry out these tests. Once the machine has been verified, the operator is responsible for ensuring that the accuracy of their machine is maintained. 3. Measuring Machine Accuracy Requirements Table 2 shows the measurement uncertainty (U#) requirements for gear measuring machines. For convenience, machines are divided into 3 accuracy classes, depending on the accuracy grade of the gears being inspected. The uncertainty relates to the accuracy of the machine when measuring a gear artefact or a master gear only. 4. Accuracy Verification Procedure The procedures for verifying the accuracy of a gear measuring machine are detailed

Laser Metrology and Machine Performance 295 in 3 EGA Codes of Practice DUCOP 05/1, 05/2 and 05/3 [2]. It is recommended that these form part of the acceptance tests on the installation of a new machine and then the tests are repeated at the frequency of between 12 to 36 months. The implementation of one or all of the codes depends on the desired size of the verified measuring volume of the machine. Most gear measuring machines check gears up to 600mm in diameter but there are a number of machines in the UK which check gears up to 2.6m diameter. The different requirements of these machines are covered by the three codes. 4.1 Verified Measuring Volume Code DUCOP 05/1 [2] defines the verified measuring volume and other limitations on the definition of uncertainty as follows: Diameter: The range of diameters is from 1.25 times the largest gear artefact diameter to 0.5 times the smallest. Facewidth: The maximum facewidth is the length of the calibrated parallel mandrel used for alignment or straightness tests. Helix angle: The largest helix angle is that which is tested on the gear artefacts. Module: The largest module is that tested on the gear artefacts. Weight: The maximum weight is 1.5 times the heaviest gear artefact measured. A specification for the geometry and NAMAS Calibration Uncertainty requirements for general purpose gear artefacts is given in DUCOP.05/1. If the artefacts do not satisfy the size required for the verified measuring volume, the volume may be extended by implementing the additional tests which are specified in DUCOP 05/2 and DUCOP 05/3. 4.2 Procedure The procedure is outlined below: Check that the environmental conditions satisfy the requirements of the codes. Verify that the machine is reproducible by examining reproducibility test results for the previous 4 week period (if they exist) to ensure that the machine being assessed is stable. Check the alignment and runout of the machine spindles, alignment of tailstock axis, and the main measuring machine vertical axis is aligned to within the recommended limits.» Check the probe system magnification, discrimination and hysteresis are within the specified limits. Each probe axis which is used to measure gear parameters or define orientation of the gear is checked. Check that the temperature of the traceably calibrated artefacts which are to be used stable and within prescribed limits. Mount each artefact on the machine and verify the mounting accuracy

296 Laser Metrology and Machine Performance before carrying out the measurement tests. Measure each calibrated flank on the artefact at 4 different angular positions on the rotary table (i.e. at 0, 90, 180 and 270 ). Calculate the mean (x) for each calibrated parameter and the standard deviation (S). Estimate the random measurement uncertainty at a 95% confidence interval for each calibrated parameter by U,,R = K.S (0 where K is a coverage factor, which in this case is chosen as 2, for the 4 tests. Estimate the overall measurement uncertainty for the measurement process for each calibrated parameter using (x - (2) where U^ is the NAMAS calibration certificate value and (x - X^,) is the bias between the two results. Verify that the U<% value calculated for each parameter satisfies the uncertainty requirements specified in Table 2. Use one lead artefact, with a 30 helix angle to check software evaluation accuracy by re-measuring the artefact with different reference data to generate a lead error of approximately 20pm. The difference between the original result and the mean of the measured results should be within the probe system specification. If the machine satisfies all the measurement test requirements, for a particular accuracy class, it has satisfied the accuracy requirements in accordance with the Code of Practice. If the artefacts available do not cover the required verified measuring volume requirements, the measuring volume may be extended by implementing the tests specified in DUCOP 05/2 and DUCOP 05/3. These additional tests are only valid as a continuation of the test programme in DUCOP 05/1. Measure the change in alignment of the machine when an additional load is applied to the work table. «Measure geometrical errors in individual slides (including the spindle) to verify that there is no excessive errors in the slides. The errors which should be checked on a 4-axis gear measuring machine (see Fig. 2) are Straightness errors Vertical axis A%y Tangential axis Ay% Angular errors Vertical axis Q^z zx @ZY Tangential axis 8yy 6%y Radial axis 8%% In addition, position errors should be checked on CNC machines, but on most machines, geometrical errors have a larger contribution to overall slide accuracy than position errors.

Laser Metrology and Machine Performance 297 The effect of these errors on machine performance will depend on the slide configuration. It is necessary to build a simple mathematical model on most machines to verify that the slides are of suitable accuracy. 4.3 Estimation of Measurement Uncertainty The functional tests on measurement performance define the uncertainty of the machine. The other tests are used to verify that the results are valid and identify the sources of systematic errors which are measured. The method of estimating 1)95 from (2) has 3 separate elements. The combination of these 3 elements in equation (2) cannot be justified statistically. In a calibration laboratory, the systematic error (bias) would be corrected, leaving the residual systematic and random uncertainty to define the overall uncertainty. Also the use of a coverage factor of K = 2 not K = 3.18, for 4 samples from Students' distribution, is unusual practice. This is used because the measurement positions (0, 90, 180, and 270 ) are not random samples, but positions chosen to maximise differences in measurement results. This unusual approach, has been validated by analysing the results from calibration records from over 50 different gear measuring machines, the results from which are retained by the National Gear Metrology Laboratory. An examination of these results shows that the U<% estimated is reasonable because very few of the differences between calibration values and the individual measured values (xj were outside combined uncertainty shown below: X, - & 4.4 Equipment The tests require a range of traceably calibrated equipment. a) Traceably calibrated gear artefacts to satisfy the requirements for the verified measuring volume. b) Parallel mandrels are used to verify slide alignment and straightness measurements. c) Differential levels, with digital display are used for verifying the accuracy of some slide angular errors. d) Calibrated indicators, 0.5pm discrimination are used for runout and alignment checks. e) A traceably calibrated laser interferometer system and environmental compensation unit is used for position accuracy verification. Geometrical errors may also be measured by using the appropriate optics and software.

298 Laser Metrology and Machine Performance 4.5 Error Compensation Very few gear measuring machines use error compensation software for systematic slide error compensation. The approach adopted if compensation is applied is that the tests on individual slide errors should be carried out but the test results should only be treated as errors if (a) the error correction method and data are disclosed by the machine manufacturer, and is considered to be valid by the calibration engineer OR (b) the accuracy of the error compensation method can be verified by independent measurement tests which are agreed between the client and the calibration engineer. 4.6 Example Measurement Results Fig. 3 shows some typical measurement results on a profile artefact indicating that the uncertainty is within class A requirements. Fig. 4 shows a slide accuracy test result with a significant angular yaw error. This could introduce an Abbe error of approximately O.Sum / 30mm of profile measured. 5. Reproducibility Tests Once the accuracy of a measuring machine has been verified, the machine operator is responsible for ensuring that accuracy is maintained. DUCOP. 04 [3] recommends tests to verify that on a day-to-day basis, the measurement results from the machine are reproducible. The routine checks include: a visual check of the condition of the machine, probe system, stylus and environmental conditions. a measurement (functional test) on a traceably calibrated master gear or lead, profile and pitch artefact. A record of the runout reference bands, machine centres and betweencentres axis alignment. verification that the difference between the gear parameter measured and the NAMAS calibration certificate value is within the combined measurement uncertainty U<%, given below (4) where U^i - NAMAS certificate U<% and U^/c - measuring machine verification that the difference between two consecutive reproducibility tests are within the U^c value (i.e. if U^/c = ±2.2 am, difference between results is less than 2.2pm). If the accuracy requirements are not satisfied, the machine may not be used for traceable gear measurement until the

Laser Metrology and Machine Performance 299 causes of the excessive errors are investigated and rectified. The frequency for reproducibility testing is specified in Table 3. 6. Discussion The procedures which have been described for verifying the accuracy of gear measuring machines are primarily based on functional measurements, as well as tests on elements of the machine which are known to cause common measurement errors. However, they also acknowledge that it is not possible to use artefacts to cover all verification requirements, particularly on the larger machines. The assessment of individual slide errors must be included as well. The codes of practice will be revised within the next 18 months based on the experience gained since their introduction. 7. Acknowledgements Design Unit gratefully acknowledge the support and help from the EGA technical committee in preparing these codes of practice and DTI 'Programme for Length' funding the work. References 1. ISO 1328-1. Cylindrical Gears - ISO System of Accuracy. 2. Codes of Practice for Verifying the Accuracy of a Gear Measuring Machine, parts 1, 2 and 3. DUCOP 05/1, 05/2, 05/3, British Gear Association, 1994. 3. Code of Practice for Verifying the Reproduceability of a Gear Measuring Machine, DUCOP.04, British Gear Association, 1994.

300 Laser Metrology and Machine Performance Parameter Tolerance Adjacent pitch 9 Cumulative pitch 27 Profile 11 Alignment 11 Measuring Machine Uncertainty 10% of tolerance 0.9 2.7 1.1 1.1 Table 1. Typical gear tolerances for lead, profile and pitch parameters [u.m]. Class of M/C A B C Grade ISO 1328 Parti 3 4 5 6 78 9 10 11 12 Maximum Allowable Measurement Uncertainty (U,,) [urn] When Measuring Gear Artefacts Adjacent Pitch Error %] ±1.8 ±2.5 ±3.5 Cumulative Pitch Error [FJ ±2.5 ±3.5 ±5.0 Alignment THO/ 100mm ±22 ( (3 = 0 ) ±3.0(P<45 ) ±25 ( (3=0 ) ±4.0 (P <45 ) ±4.0(P = 0 ) ±6.0(P<45 ) Profile W40 mm ±1.8 ±25 ±4.0 Table 2. Accuracy requirements of gear measuring machines Class A B C Lead and Profile Reproduceability Before each series of tests Every 24 hours 1 week Pitch Reproducibility 1 week 1 week 1 month Table 3. Frequency of reproduceability tests.

Laser Metrology and Machine Performance 301 Fig. la Traditional Mechanical Gear Inspection Machine Fig. 1 b CNC Gear Inspection Machine CJ2 Z(VERTICAL AXIS) BETWEEN CENTRE AXIS \ I Y(TANGENTIAL AXIS) SPINDLE Fig.2 Definition of axes

302 Laser Metrology and Machine Performance Flank PTB CaL Data Repeat Tests x S u* Left Right -1.1 ±1.0 +0.3 ±1.0-1.4, -0.7, -1.4, -1.3 +0.2, 0.0, +0.1, +0.4-1.2 +0.2 0.3 0.2 1.2 1.1 Quality Tip 1 : 1 O 10 o 0 + 1000 : : CL 010<> i pm Root Umit Value Fa-/- f,a-/- W-/- Reqd.pp:- / Le: - Aet.pr:- / Read, pp; _ / Le: - Act. pn- /! 4 3 Lett Rank 2 1 toeth 1 2 Right Rank 3 4 ' LEFT RIGHT 215.5 190.2 215.5 ( 90.23 4 3 2 1 Limit Value 1 2 3 4 3.7 3.7I- -/- 3.6 36l- 4.0 4.0l- -/- 3.5 3 6 1- I -1.4-1.41- -/-.2.2-1 + Fig. 3 Profile artefact - profile measurement results and comparison with calibration certificate value Fig. 4 All Data Plot - Angle Target " (millimetres) Machine:HOFLER EMZ Ax is: X-AXIS Serial Mo: 076181 Location: Date: 13: 19 Feb 17 1995 Filename: D1ZXYAW.RTA By.RCF Bidirectional Typical Side Yaw Error (um/m) Result from a Renishaw Laser Interferometer