Health Science & Human Services Center 100% CONSTRUCTION DOCUMENTS RSA Project No September 1, 2017(REVISED 9/21/17)

Size: px
Start display at page:

Download "Health Science & Human Services Center 100% CONSTRUCTION DOCUMENTS RSA Project No September 1, 2017(REVISED 9/21/17)"

Transcription

1 SECTION VOLUME 1 INTRODUCTORY INFORMATION Seals Page... Sept. 1, Table of Contents... Sept. 1, 2017 Sept. 21, 2017 DIVISION 00 - BIDDING REQUIREMENTS AND CONTRACT FORMS Geotechnical Data... Sept. 1, 2017 Geotechnical Report Geotechnical Report Addendum Uniform General and Supplementary Conditions Architect s Special Conditions... Sept. 1, Finish Selection Summary... Sept. 1, 2017 Sept. 21, 2017 DIVISION 01 - GENERAL REQUIREMENTS Summary... Sept. 1, Allowances... Sept. 1, Unit Prices... Sept. 1, Alternates... Sept. 1, 2017 Sept. 21, Substitution Procedures... Sept. 1, Substitution Request Form... Sept. 1, Contract Modification Procedures... Sept. 1, Payment Procedures... Sept. 1, Project Management and Coordination... Sept. 1, Construction Progress Documentation... Sept. 1, Photographic Documentation... Sept. 1, Submittal Procedures... Sept. 1, Quality Requirements... Sept. 1, References... Sept. 1, Temporary Facilities and Controls... Sept. 1, Mold Prevention Measures... Sept. 1, Tree and Plant Protection, Removal, and Pruning... Sept. 1, Product Requirements... Sept. 1, Execution... Sept. 1, Closeout Procedures... Sept. 1, Operation and Maintenance Data... Sept. 1, Project Record Documents... Sept. 1, Demonstration and Training... Sept. 1, 2017 DIVISION 03 CONCRETE Concrete Pigments (Integral Color)... Sept. 1, Cast-in-Place Concrete... Sept. 1, Architectural Concrete... Sept. 1, Concrete Floor Finishing... Sept. 1, Clear Concrete Sealer... Sept. 1, 2017 DIVISION 04 - MASONRY Unit Masonry... Sept. 1, Cast Stone Masonry... Sept. 1, 2017 DIVISION 05 - METALS Structural Steel... Sept. 1, Architecturally Exposed Structural Steel Framing... Sept. 1, Steel Deck... Sept. 1, Cold-Formed Metal Framing... Sept. 1, 2017 RSA Project No September 1, 2017(REVISED 9/21/17)

2 Metal Fabrications... Sept. 1, Metal Stairs... Sept. 1, Pipe and Tube Railings... Sept. 1, Decorative Railings... Sept. 1, 2017 DIVISION 06 - WOOD AND PLASTICS Miscellaneous Rough Carpentry... Sept. 1, Sheathing... Sept. 1, Interior Finish Carpentry... Sept. 1, Custom Casework... Sept. 1, Glass Fiber Reinforced Plastic Paneling... Sept. 1, 2017 DIVISION 07 - THERMAL AND MOISTURE PROTECTION Fluid-Applied Waterproofing System... Sept. 1, Crystalline Waterproofing... Sept. 1, Floor Waterproofing... Sept. 1, Thermal Building Insulation... Sept. 1, Below-Grade Vapor Retarders... Sept. 1, Fluid-Applied Membrane Air Barriers... Sept. 1, Clay Roof Tiles... Sept. 1, Metal Wall Panels... Sept. 1, 2017 DELETED Terra Cotta Rainscreen Cladding... Sept. 1, Composite Aluminum Wall Panels... Sept. 1, SBS Modified Bituminous Membrane Roofing... Sept. 1, Sheet Metal Flashing and Trim... Sept. 1, Manufactured Roof Specialties... Sept. 1, Roof Accessories... Sept. 1, Applied Fireproofing... Sept. 1, Intumescent Fireproofing... Sept. 1, Firestopping... Sept. 1, Joint Firestopping... Sept. 1, Joint Sealants... Sept. 1, 2017 DIVISION 08 - DOORS AND WINDOWS Hollow Metal Doors and Frames... Sept. 1, Interior Aluminum Frames... Sept. 1, Flush Wood Doors... Sept. 1, Access Doors and Frames... Sept. 1, Elevator Door Smoke Containment Curtain... Sept. 1, Automatic Perimeter Fabric Fire Barrier Enclosure... Sept. 1, Aluminum-Framed Entrances and Storefronts... Sept. 1, All-Glass Entrances and Storefronts... Sept. 1, Glazed Aluminum Curtain Walls... Sept. 1, Translucent Linear Channel Glazing System... Sept. 1, Door Hardware... Sept. 1, Automatic Door Operators... Sept. 1, Glazing... Sept. 1, Decorative Glazing Film... Sept. 1, Louvers... Sept. 1, 2017 DIVISION 09 - FINISHES Portland Cement Stucco... Sept. 1, Gypsum Board Assemblies... Sept. 1, Tiling... Sept. 1, Acoustical Panel Ceilings... Sept. 1, Acoustical Metal Ceilings... Sept. 1, Resilient Base and Accessories... Sept. 1, Resilient Sheet Flooring... Sept. 1, Resilient Tile Flooring... Sept. 1, Rubber Flooring... Sept. 1, Resinous Matrix Terrazzo Flooring... Sept. 1, 2017 RSA Project No September 1, 2017(REVISED 9/21/17)

3 Tile Carpeting... Sept. 1, Wall Covering... Sept. 1, Stretched-Fabric Wall Systems... Sept. 1, Digital Graphic Wall Panels... Sept. 1, Painting... Sept. 1, Steel Coatings... Sept. 1, 2017 DIVISION 10 SPECIALTIES Visual Display Boards... Sept. 1, Signage... Sept. 1, Stainless Steel Toilet Compartments... Sept. 1, Cubicle Curtains and Tracks... Sept. 1, 2017 Sept. 21, Operable Partitions... Sept. 1, Horizontal Sliding Accordion-Type Fire Door... Sept. 1, Wall and Corner Guards... Sept. 1, Toilet Accessories... Sept. 1, Fire Protection Specialties... Sept. 1, Plastic-Laminate-Clad Lockers... Sept. 1, Bird Control Devices... Sept. 1, Grilles... Sept. 1, 2017 DIVISION 11 - EQUIPMENT Building Maintenance Equipment... Sept. 1, Residential Appliances... Sept. 1, Lectern... Sept. 1, Patient Care Equipment... Sept. 1, 2017 DIVISION 12 - FURNISHINGS Roller Window Shades... Sept. 1, Quartz Countertops... Sept. 1, Stone Countertops... Sept. 1, 2107 DELETED Cubicle Curtains and Tracks... Sept. 1, 2017 DELETED Solid Surface Countertops... Sept. 21, Entrance Floor Mats... Sept. 1, 2017 DELETED Site Furnishings... Sept. 1, 2017 DIVISION 13 - SPECIAL CONSTRUCTION Radiation Protection... Sept. 1, 2017 DIVISION 14 - CONVEYING SYSTEMS Electric Traction Elevators... Sept. 1, 2017 VOLUME 2 DIVISION 21 - FIRE SUPPRESSION Jockey Pumps... Sept. 1, Controllers for Fire Pump Drives... Sept. 1, 2017 DIVISION 22 - PLUMBING Common Work Results for Plumbing... Sept. 1, Meters and Gages for Plumbing Piping... Sept. 1, General Duty Valves for Plumbing Piping... Sept. 1, Hangers and Supports for Plumbing Piping and Equipment... Sept. 1, Identification for Plumbing Piping and Equipment... Sept. 1, Plumbing Insulation... Sept. 1, Domestic Water Piping... Sept. 1, Domestic Water Piping Specialties... Sept. 1, Domestic Water Pumps... Sept. 1, 2017 RSA Project No September 1, 2017(REVISED 9/21/17)

4 Domestic Water Packaged Booster Pumps... Sept. 1, SANITARY WASTE AND VENT PIPING... Sept. 21, SANITARY WASTE PIPING SPECIALTIES... Sept. 21, Sanitary Waste Interceptors... Sept. 1, Facility Storm Drainage Piping... Sept. 1, Facility Subsoil Drainage Piping... Sept. 1, Storm Drainage Piping Specialties... Sept. 1, Domestic Water Softeners... Sept. 1, Electric Domestic Water Heaters... Sept. 1, Domestic Water Heat Exchangers... Sept. 1, Plumbing Fixtures... Sept. 1, Emergency Plumbing Fixtures... Sept. 1, Drinking Fountains and Water Coolers... Sept. 1, Medical Compressed Air Piping for Healthcare Facilities... Sept. 1, Compressed Air Equipment for Healthcare Facilities... Sept. 1, Vacuum Piping for Healthcare Facilities... Sept. 1, Vacuum Equipment for Healthcare Facilities... Sept. 1, Gas Piping for Healthcare Facilities... Sept. 1, 2017 DIVISION 23 - HEATING AND AIR CONDITIONING HVAC Air Duct Cleaning... Sept. 1, Common Work Results for HVAC... Sept. 1, Common Motor Requirements for HVAC Equipment... Sept. 1, Expansion Fittings and Loops for HVAC Equipment... Sept. 1, Meters and Gages for HVAC Piping... Sept. 1, General Duty Valves for HVAC Piping... Sept. 1, Hangers and Supports for HVAC Piping and Equipment... Sept. 1, Vibration and Seismic Controls for HVAC Piping and Equipment... Sept. 1, Identification for HVAC Piping and Equipment... Sept. 1, Testing, Adjusting, and Balancing for HVAC... Sept. 1, HVAC Insulation... Sept. 1, Instrumentation and Control for HVAC... Sept. 1, 2017 Sept. 21, Facility Natural Gas Piping... Sept. 1, Hydronic Piping... Sept. 1, Hydronic Piping Specialties... Sept. 1, Hydronic Pumps... Sept. 1, Steam and Condensate Piping... Sept. 1, Steam and Condensate Piping Specialties... Sept. 1, 2017 Sept. 21, Refrigerant Piping... Sept. 1, Metal Ducts... Sept. 1, Air Duct Accessories... Sept. 1, 2017 Sept. 21, HVAC Fans... Sept. 1, Air Terminal Units... Sept. 1, Diffusers, Registers, and Grilles... Sept. 1, HVAC Air Cleaning Devices... Sept. 1, Breechings, Chimneys, and Stacks... Sept. 1, Condensing Boilers... Sept. 1, Heat Exchangers for HVAC... Sept. 1, Modular Indoor Central Stations Air Handling Units... Sept. 1, 2017 Sept. 21, Computer-Room Air Conditioners... Sept. 1, Split System Air Conditioners... Sept. 1, Fan Coil Units... Sept. 1, Unit Heaters... Sept. 1, Humidifiers... Sept. 1, 2017 VOLUME 3 DIVISION 26 - ELECTRICAL Common Work Results for Electrical... Sept. 1, 2017 RSA Project No September 1, 2017(REVISED 9/21/17)

5 Medium-Voltage Cables... Sept. 1, Low-Voltage Electrical Power Conductors and Cables... Sept. 1, Grounding and Bonding for Electrical Systems... Sept. 1, Hangers and Supports for Electrical Systems... Sept. 1, Raceways and Boxes for Electrical Systems... Sept. 1, Pathways for Special Systems... Sept. 1, Underfloor Raceways for Electrical Systems... Sept. 1, Underground Ducts and Raceway for Electrical Systems... Sept. 1, Vibration and Seismic Controls for Electrical Systems... Sept. 1, Identification for Electrical Systems... Sept. 1, Overcurrent Protective Device Coordination Study... Sept. 1, Lighting Control Devices... Sept. 1, Network Lighting Controls... Sept. 1, Low-Voltage Transformers... Sept. 1, Switchboards... Sept. 1, Panelboards... Sept. 1, Electrical Cabinets and Enclosures... Sept. 1, Wiring Devices... Sept. 1, Fuses... Sept. 1, Enclosed Switches and Circuit Breakers... Sept. 1, Enclosed Controllers... Sept. 1, Variable-Frequency Motor Controllers... Sept. 1, Engine Generators... Sept. 1, Static Uninterruptible Power Supply... Sept. 1, Transfer Switches... Sept. 1, Lightning Protection for Structures... Sept. 1, Surge Protective Devices... Sept. 1, Interior Lighting... Sept. 1, Exterior Lighting... Sept. 1, 2017 DIVISION 27 - COMMUNICATIONS Communications... Sept. 1, Grounding and Bonding for Communications Systems... Sept. 1, Pathways for Communications Systems... Sept. 1, Optical Fiber Testing and Measurement... Sept. 1, Communications Room Fittings... Sept. 1, Backbone Cabling... Sept. 1, Horizontal Cabling... Sept. 1, Architecturally Integrated Audio Visual Infrastructure... Sept. 1, Audio Visual Systems... Sept. 1, 2017 DIVISION 28 - ELECTRONIC SAFETY AND SECURITY Electronically Security... Sept. 1, Common Work Results for Electronic Safety and Security... Sept. 1, Access Control and Intrusion Detection... Sept. 1, Video Surveillance... Sept. 1, Emergency Intercom and Duress... Sept. 1, Fire Detection and Alarm... Sept. 1, Refrigerant Detection and Duress... Sept. 1, 2017 DIVISION 31 - EARTHWORK Site Preparation... Sept. 1, Earth Moving... Sept. 1, Subgrade Preparation... Sept. 1, Excavation and Backfill for Conduits... Sept. 1, Erosion Control... Sept. 1, Termite Control... Sept. 1, Drilled Piers... Sept. 1, 2017 DIVISION 32 - EXTERIOR IMPROVEMENTS Landscape - Maintenance of Site Improvements - Two Years... Sept. 1, 2017 RSA Project No September 1, 2017(REVISED 9/21/17)

6 Portland Cement Concrete Paving... Sept. 1, Concrete Paving - Architectural Finishes... Sept. 1, Precast Concrete Unit Paving... Sept. 1, Concrete Curbs and Gutters... Sept. 1, Pavement Markings... Sept. 1, Landscape Irrigations System... Sept. 1, Turf and Grasses... Sept. 1, Landscaping - Organic... Sept. 1, 2017 DIVISION 33 - UTILITIES Water Conduit Installation... Sept. 1, Sanitary Sewer Line Installation... Sept. 1, Storm Sewer Line Installation... Sept. 1, Landscape Drainage with Bridging Stone... Sept. 1, 2017 END OF RSA Project No September 1, 2017(REVISED 9/21/17)

Roof and Wall Specialties and Accessories

Roof and Wall Specialties and Accessories CSI CODE REFERENCE All contents copyright 2014, The Construction Specifications Institute and Construction Specifications Canada. All rights reserved. MasterFormat Numbers & Titles 05 00 00 Metals 05 52

More information

ADDENDUM 3. C. Bidders are requested to attach a copy of this Addendum to the Project Manual in their possession.

ADDENDUM 3. C. Bidders are requested to attach a copy of this Addendum to the Project Manual in their possession. Network Operations Center Renovation 62 Swamp Road Newtown, PA 18940 ADDENDUM 3 To: For: Prepared For: ALL BIDDERS Network Operation Center Renovation 62 Swamp Road Newtown, PA 18940 Council Rock School

More information

WORKERS' COMPENSATION AND EMPLOYERS LIABILITY TENNESSEE NCCI CONTRACTING INDUSTRY GROUP As of March 1, 2013.

WORKERS' COMPENSATION AND EMPLOYERS LIABILITY TENNESSEE NCCI CONTRACTING INDUSTRY GROUP As of March 1, 2013. WORKERS' COMPENSATION AND EMPLOYERS LIABILITY TENNESSEE NCCI CONTRACTING INDUSTRY GROUP 50-6-113 As of March 1, 2013 Class Code Sort CODE DESCRIPTION 0042 LANDSCAPE GARDENING & DRIVERS 0050 FARM MACHINERY

More information

CITY OF STANDARD SPECIFICATIONS

CITY OF STANDARD SPECIFICATIONS CITY OF Published May 4, 2016 CALIFORNIA Stephan Kiefer, Community Development Director Cheri Sheets, City Engineer CITY OF LIVERMORE 1052 South Livermore Avenue Livermore, CA 94550 4DEV0001.doc 03/12

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

MAINTENANCE CATAGORIES. Visual inspection, cleaning. Repair large scale cracks or settling, major repairs/ replacement. Hire Structural Engineer.

MAINTENANCE CATAGORIES. Visual inspection, cleaning. Repair large scale cracks or settling, major repairs/ replacement. Hire Structural Engineer. COMPREHENSIVE MAINTENANCE PLAN SCHOOL FACILITIES MAINTENANCE CATAGORIES 1 Structural Foundations Routine inspection for cracks, deterioration, infiltration. Localized repair of cracks and spalling with

More information

James N Thorp Elementary School

James N Thorp Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

METAL STUDS. TOTAL COST (Labor+ Material) UNIT COST (Labor+ Material) ITEM # DESCRIPTION QUANTITY UNIT TRADE COST GENERAL REQUIREMENTS

METAL STUDS. TOTAL COST (Labor+ Material) UNIT COST (Labor+ Material) ITEM # DESCRIPTION QUANTITY UNIT TRADE COST GENERAL REQUIREMENTS GENERAL REQUIREMENTS 1 Supervision (5%) 1.00 LS 0.00 $0 2 Permits (5%) 1.00 LS 0.00 $0 3 Final Cleanup (0.2 Per SF) 1.00 LS 0.00 $0 4 Mobilization Costs (5%) 1.00 LS 0.00 $0 5 Project Overheads (7.3%)

More information

METRO Magnolia Transit Center - Bid Tab

METRO Magnolia Transit Center - Bid Tab Section A - GENERAL ITEMS A-1 01505 Mobilization LS 1 $ 100,000.00 $ 100,000.00 A-2 -- Payment and Performance Bonds LS 1 A-3 01310 Document Control LS 1 A-4 01311 CPM Schedule LS 1 A-5 01590 Engineer's

More information

Architect s Guide for Detailing & Specifying Access Floor Air Plenums

Architect s Guide for Detailing & Specifying Access Floor Air Plenums Access Floors Architect s Guide for Detailing & Specifying Access Floor Air Plenums Access Floors to the Power of 1 Access floor air plenum integrity begins with proper design and specification. 2 Architect

More information

BISCAYNE POINT ROW IMPROVEMENTS

BISCAYNE POINT ROW IMPROVEMENTS NEIGHBORHOOD & PROJECT NAME FUNDING SOURCE NO. 1 BISCAYNE POINT NEIGHBORHOOD BISCAYNE POINT ROW IMPROVEMENTS BISCAYNE POINT AREA STREETSCAPE G.O. BONDS IMPROVEMENTS WATER & SEWER BISCAYNE POINT WATER LINE

More information

NEC 2011 Code Changes

NEC 2011 Code Changes NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Group Class Code Listing

Group Class Code Listing Group Class Code Listing 1000 Automotive; Parts, Components, Vehicles 1160 Surplus - Bus & Bus Parts 1010 Automotive Parts 1200 Trolleys; Parts, Components 1020 Automotive - Testing Equipment 1202 Trolley

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

East Allen County Schools Facilities History Calendar Years October 5, 2015

East Allen County Schools Facilities History Calendar Years October 5, 2015 East Allen County Schools Facilities History Calendar Years 2007 2015 October 5, 2015 Heritage Attendance Area Heritage Jr./Sr. High School (includes K-12) 2007: Repaved Front Student Parking Lot; and

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION DUCTWORK ACCESSORIES

SECTION DUCTWORK ACCESSORIES SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference

More information

UNLV Animal Care Facility. University of Nevada Las Vegas CAM 1513/PC ADDENDUM B August 19, 2016

UNLV Animal Care Facility. University of Nevada Las Vegas CAM 1513/PC ADDENDUM B August 19, 2016 UNLV Animal Care Facility University of Nevada Las Vegas ADDENDUM B August 19, 2016 Owner: Architect: To: University of Nevada Las Vegas 4505 S. Maryland Parkway Las Vegas, Nevada 89154 Tate Snyder Kimsey

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION VII METERING INSTALLATIONS

SECTION VII METERING INSTALLATIONS SECTION VII METERING INSTALLATIONS 1. GENERAL Outdoor metering is required for all new service installations to one, two, and three family detached, semi-detached and row houses. 2. COMPANY FURNISHES AND

More information

Inspection Points - Motor Homes

Inspection Points - Motor Homes Inspection Points - Motor Homes We at RVIS, LLC appreciate your business and look forward to providing you with the professional RV inspection you deserve. So that we may provide you with a thorough inspection,

More information

F9 PROPERTIES LUMBER LIQUIDATORS FACILITY 307,184 + /- Square Feet on /- acres Toano, Virginia

F9 PROPERTIES LUMBER LIQUIDATORS FACILITY 307,184 + /- Square Feet on /- acres Toano, Virginia F9 PROPERTIES LUMBER LIQUIDATORS FACILITY 307,184 + /- Square Feet on 74.4 + /- acres Toano, Virginia (PRELIMINARY) F9 LUMBER LIQUIDATORS 3000 JOHN DEERE DR STONEHOUSE COMMERCE PARK SIZE: GROUND: NUMBER

More information

Building Integrity Property Services

Building Integrity Property Services Cover Page Property Inspection Report 33032 Inspection prepared for: WILLIAM CLARK Date of Inspection: 1/4/2016 Age of Home: 1996 Size: 1,710SF ADJUSTED Inspector: Alexis Nogueras License #2676 14325 SW

More information

RETAIL BASE BUILDING REQUIREMENTS DATE: 02/04/2016

RETAIL BASE BUILDING REQUIREMENTS DATE: 02/04/2016 RETAIL BASE BUILDING REQUIREMENTS DATE: 02/04/2016 Overview The following requirements outline the guidelines for designers and project delivery teams in the planning, design and infrastructure requirements

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9 Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6

More information

SECTION ROLLER WINDOW SHADES

SECTION ROLLER WINDOW SHADES SECTION ROLLER WINDOW SHADES Specifier: The Specifier/Design Professional is responsible for the accuracy of all project specifications, including system application and coordination with related sections.

More information

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers AMCA International Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. The International

More information

SECTION METAL LOCKERS

SECTION METAL LOCKERS SECTION 10 5113 METAL LOCKERS This section includes editing notes to assist the user in editing the section to suit project requirements. These notes are included as hidden text, and can be revealed or

More information

CODE ANALYSIS BUILDING AREA STORIES 2 BUILDING HEIGHT 25'

CODE ANALYSIS BUILDING AREA STORIES 2 BUILDING HEIGHT 25' CODE ANALYSIS APPLICABLE CODES (*- w/ local amendments) BUILDING CODE IBC 2006 * PLUMBING CODE IPC 2006* MECHANICAL CODE IMC 2006* ELECTRICAL CODE NFPA 70 (NEC) 2008* ENERGY CONSERVATION CODE IECC 2006

More information

PROJ. NO SECTION HYDRONIC PUMPS

PROJ. NO SECTION HYDRONIC PUMPS SECTION 23 21 23 HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated

More information

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet DRAWING NUMBER INTRODUCTORY INFORMATION Important Notices Underground Plant Protection Information Code Clearances Commercial/Industrial Information Sheet Work Management Customer Projects Engineering

More information

F. VAV hoods shall have a restricted bypass plate.

F. VAV hoods shall have a restricted bypass plate. 1.01 SUMMARY A. Section Includes: 1. Laboratory fume hoods. B. Related Sections: 1. Section 6500 Laboratory casework 2. Section 15 Mechanical: Furnishing and installation of plumbing utilities and final

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less. PART 1: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference 2010 / PM CM 21st Annual Conference The High-Velocity Edge: Achieving Operational Excellence ELECTRICAL / PM CM 2010 Conference Basic Electrical Rick Miller, PE, LEED AP RNM Engineering, Inc. Vanir Corp.

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Composite PEX-AL-PEX Tubing

Composite PEX-AL-PEX Tubing 04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SARTELL PUBLIC SAFETY CAMPUS November 20 21, 2018

SARTELL PUBLIC SAFETY CAMPUS November 20 21, 2018 # SECURI TY PPB A A2 A3 A4 A5 A6 A7 M M2 M3 M4 M5 3A CONCRETE EBERT CONSTRUCTION $ 420,400.00 $ 247,500.00 667,900.00 K. JOHNSON CONSTRUCTION, INC $ 20,000.00 $ 249,250.00 450,250.00 ULTRA CONCRETE, LLC

More information

Maine Turnpike Authority

Maine Turnpike Authority York Toll Plaza Mile 8.8 201.11 Clearing 17.00 AC 202.15 Removing Existing Manhole or Catch Basin 22.00 EA 202.151 Abandoning Existing Manhole or Catch Basin 10.00 EA 202.16 Removing Existing Pipe 575.00

More information

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE SECTION 11 53 00 (11610) - LABORATORY FUME HOODS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1

More information

Fertilizer Type B 2 CWT $ $ $60.00 $ $60.00 $ Sod Water 60 MGAL $60.60 $3, $30.00 $1, $30.00 $1,

Fertilizer Type B 2 CWT $ $ $60.00 $ $60.00 $ Sod Water 60 MGAL $60.60 $3, $30.00 $1, $30.00 $1, BID TABS PROJECT 18-1029 22 nd AVENUE RECONSTRUCTION BID DATE: MAY 9, 2018 Stark Pavement Corp. Lalonde Contractors Cornerstone Pavers LLC Brookfield, WI Waukesha, WI Racine, WI Item Number Roadway Quantity

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

CONTRACTOR'S REQUEST FOR PAYMENT CHASKA VETERANS PARK IMPROVEMENTS STANTEC PROJECT NO

CONTRACTOR'S REQUEST FOR PAYMENT CHASKA VETERANS PARK IMPROVEMENTS STANTEC PROJECT NO Owner: City of Chaska, 1 City Hall Plz., Chaska, mn 55318 Date: December 12, 2017 For Period: 12/1/2017 to 1/31/2018 Request No: 1 Contractor: Blackstone Contractors, LLC, 9520 County Rd. 19, Ste. D, Loretto,

More information

Architect s Guide for Detailing & Specifying Access Floor Air Plenums

Architect s Guide for Detailing & Specifying Access Floor Air Plenums Access F l o o rs Architect s Guide for Detailing & Specifying Access Floor Air Plenums Access Floors to the Power of 1 Access floor air plenum integrity begins with proper design and specification. 2

More information

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES SECTION - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

A. This section includes unit capacitors for power factor correction.

A. This section includes unit capacitors for power factor correction. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

PROJ. NO SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

PROJ. NO SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 23 74 13 PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Home Maintenance Schedule

Home Maintenance Schedule January January Chores Clean sink & tub drains with baking soda. Pour water down unused drains. Apply wood protectant to cabinets & trim. Check window & door tracks to see if weep holes are open. Clean

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

B E C K E R & F R O N D O R F Construction Cost Consulting Project Management

B E C K E R & F R O N D O R F Construction Cost Consulting Project Management Project: Okehocking Nature Center Number: 07142E2 Client: M2 Architecture Date: June 5, 2009 Phase: DD B E C K E R & F R O N D O R F Construction Cost Consulting Project Management ESTIMATE SUMMARY CODE

More information

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible

More information

CITY AND COUNTY OF DENVER DEPARTMENT OF PUBLIC WORKS STATEMENT OF QUANTITIES. Item No. Description Estimated Quantity

CITY AND COUNTY OF DENVER DEPARTMENT OF PUBLIC WORKS STATEMENT OF QUANTITIES. Item No. Description Estimated Quantity 202-00019 Removal of Inlet 15 EA 202-00035 Removal of Pipe 121 LF 202-00200 Removal of Sidewalk 1,057 SY 202-00203 Removal of Curb and Gutter 2,142 LF 202-00206 Removal of Concrete Curb Ramp 320 SY 202-00207

More information

PRODUCED BY AN AUTODESK STUDENT PRODUCT. View Name. Ref. Breakheart Project

PRODUCED BY AN AUTODESK STUDENT PRODUCT. View Name. Ref. Breakheart Project t 0 WINDOW TAG DOOR TAG Revit 99 Spring 0 NORTH PERSPECTIVE SOUTH PERSPECTIVE Breakheart Project Ref View Name Set on a rural site in the Appalachian Mountains, the Breakheart Project stands ready for

More information

TABLE II Electrical Permit Fees

TABLE II Electrical Permit Fees TABLE II Electrical Permit Fees Fees are per each item to be installed or altered Electrical Permit Item 1 Fee Residential Replacement or Altered Service 2 Electrical service 0-200 amps with feeder $73.78

More information

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service

More information

Steese Rd - Curb & Sidewalk Improvement

Steese Rd - Curb & Sidewalk Improvement REF. NO. ITEM NO. Steese Rd - Curb & Sidewalk Improvement DESCRIPTION QTY UNITS UNIT COST SUB-TOTAL 1 103.05 Requirement of Contract Bid 1 LS 24,048.00 24,048.00 2 201 Clearing and Grubbing 1 LS 11,077.00

More information

Expedition vehicle UM 8-FH-AS / Unimog 4x4

Expedition vehicle UM 8-FH-AS / Unimog 4x4 Expedition vehicle UM 8-FH-AS / Unimog 4x4 Opportunity World trip proven vehicle for 2 people. This vehicle is ideal for all kinds of expeditions or adventure trips. 7.49 ton registration possible. You

More information

ADDENDUM No. 1 Prospective Bidders

ADDENDUM No. 1 Prospective Bidders Page 1 of 1 Attachment to Addendum # 1 Revised Itemized Bid ADDENDUM No. 1 TO: Prospective Bidders FROM: Gregory Tate, Construction Contracts Administrator DATE: January 24, 2019 PROJECT: Traffic Signal

More information

BUILDING PERMIT FEES BUILDING VALUATION DATA

BUILDING PERMIT FEES BUILDING VALUATION DATA BUILDING PERMIT FEES BUILDING VALUATION DATA The unit costs are intended to comply with the definition of "valuation" in Section 223 of the 1997 Uniform Building Code and thus include architectural, structural,

More information

ROLLER SHADE SPECIFICATIONS

ROLLER SHADE SPECIFICATIONS Part 1 General 1.1 Scope A. Furnish and install roller shades provided by Fabtex Inc., (800) 778-2791 B. Substitutions: Not Permitted C. Related work specified elsewhere 1.2 Quality Assurance A. Installer

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Related Sections: 1. Section 15050 - Basic Mechanical Requirements. 2. Section 15051 - Motors. 3. Section 15185 - Hydronic Pumps. 4. Section 15625 - Centrifugal

More information

The 2017 Program will be comprised of the following: Long Term Projects $15,295,100 Short Term Projects 18,000,100 TOTAL $33,295,200

The 2017 Program will be comprised of the following: Long Term Projects $15,295,100 Short Term Projects 18,000,100 TOTAL $33,295,200 PITTSBURGH SCHOOL DISTRICT 2017/2023 CAPITAL PROGRAM The following is the proposed 2017 / 2023 Capital Program. These projects have been identified as a result of Board Actions, input from Facilities,

More information

Project Book Worksheet for Cost Estimation

Project Book Worksheet for Cost Estimation 001.01 MOBILIZATION LS $34,716.18 007 3/17/2039 001.02 INCIDENTAL LS $23,929.43 019 3/17/2039 001.03 CONSTRUCTION STAKING LS $10,504.39 201 5/9/2013 001.04 REESTABLISH PROPERTY CORNERS EA $496.08 201 5/9/2013

More information

UNLV Animal Care Facility. University of Nevada Las Vegas CAM 1513/PC ADDENDUM A August 5, 2016

UNLV Animal Care Facility. University of Nevada Las Vegas CAM 1513/PC ADDENDUM A August 5, 2016 UNLV Animal Care Facility University of Nevada Las Vegas ADDENDUM A August 5, 2016 Owner: Architect: To: University of Nevada Las Vegas 4505 S. Maryland Parkway Las Vegas, Nevada 89154 Tate Snyder Kimsey

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

www.nrvh.com 909.943.6007 3411 North Perris Blvd. Perris, CA 92571 Due to continued product improvement, National R.V., Inc. reserves the right to change materials, colors, specifications and prices at

More information

SECTION BASIC ELECTRICAL REQUIREMENTS

SECTION BASIC ELECTRICAL REQUIREMENTS SECTION 16001 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION LIFT ARM PARKING GATES

SECTION LIFT ARM PARKING GATES St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 SECTION 11 12 33.13 LIFT ARM PARKING GATES PART 1 - GENERAL 1.01 SUMMARY A. Section

More information

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES Page 226113-1 SECTION 226113 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE) Please indicate which products and services your company can supply by checking the appropriate box(es). Check only the first box if your company can supply all of the products and services shown for this

More information

Spring Test 10 due 05/11/2013

Spring Test 10 due 05/11/2013 Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SUNY GENESEO 220523-1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

New homes from the $170 s - $220 s

New homes from the $170 s - $220 s at Preliminary Brochure New homes from the $170 s - $220 s Reeds Edge at Long Bay Golf Club offers new homes in a beautiful golf community setting near the intersection of Highway 9 and 905! Each home

More information

SUBMITTAL COVER SHEET

SUBMITTAL COVER SHEET SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.

More information

DRYER EXHAUST VENT FLASHINGS

DRYER EXHAUST VENT FLASHINGS SECTION B DRYER EXHAUST VENT FLASHINGS A-0 DRYER EXHAUST VENT FLASHINGS TABLE OF CONTENTS Thaler Or Equal Dryer Exhaust Vent Flashings (Flat/Low Slope Roofs) Dryer Exhaust Vent Flashings (Sloped Roofs)

More information

Inventory # Lot # Lead

Inventory # Lot # Lead 2125800 5 Transformer Cooler 2125801 6 Valves 2125802 7 Globe Valve 2125803 8 Check Valve 2125804 9 Flow Control Valve 2125805 10 Tricentic Valves 2125806 11 Gate Valve 2125807 12 Gate Valves 2125808 13

More information

STANDARD DRAWING INDEX

STANDARD DRAWING INDEX ATTACHMENT B STANDARD DRAWING INDEX DESCRIPTION EXISTING DRAWING NO. GENERAL Typical Layout for Improvement Plans City of Stockton Standard Border and Title Block for 8 1/2 x11 Sheet City of Stockton Standard

More information

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems. Issued 2005/06/01 Section 15440 Plumbing Pumps Page 1 of 9 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout

More information

LABORATORY FUME HOODS OF 5

LABORATORY FUME HOODS OF 5 SECTION 11 5313 - LABORATORY FUME HOODS AND RELATED PRODUCTS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Bench-top laboratory fume hoods. 2. Service fittings and electrical service fitting inside

More information

UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK

UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK 5 October 2017 John A. Weber Principal Electrical Engineer, Hartford Steam Boiler Inspection and Insurance Company Electrical Power Transmission

More information

Maine Turnpike Authority

Maine Turnpike Authority Interchange 44 Barrier Toll Plaza Open Road Tolling Conversion Mile 44.3 201.11 CLEARING 3.50 AC 202.071 REMOVING ASBESTOS CONTAINING MATERIALS, TOLL BOOTH LAB TOPS 1.00 LS 202.081 REMOVING EXISTING BUILDING

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL 13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-1 SECTION 22 1519 - GENERAL-SERVICE AIR COMPRESSOR 1.1 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of the Contract, including General

More information

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SECTION 220523 - GENERAL-DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

HILLS MATERIALS COMPANY UNIT COST TOTAL COST UNIT COST TOTAL COST UNIT COST $294, $294, $74, $74, $35, $35,000.

HILLS MATERIALS COMPANY UNIT COST TOTAL COST UNIT COST TOTAL COST UNIT COST $294, $294, $74, $74, $35, $35,000. PROJECT NAME: Anamosa Street Reconstruction - Midway Street to Miiwuakee Street PROJECT NUMBER: PROJECT NO. 07-1473 / CIP NO. 50559 LET DATE: April 11, 2017 LOW BID AMOUNT: $3,941,397.20 ENGINEER'S ESTIMATE

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information