Information. Lighting Hoist. Version 10/07.

Size: px
Start display at page:

Download "Information. Lighting Hoist. Version 10/07."

Transcription

1 Lighting Hoist Version 10/07

2

3 1.30m to 9.30m U = Length of Unistrut ( S m minimum ) S = Rope Spacing S/2 S/ m up to16.50m P = Studio Rail ( S minimum ) Lighting Hoist - General Dimensions Diverter Unit Winding unit with electric motor and limit switches Unistrut RH Diverter assembly Wire ropes Self folding cable system Socket boxes Conduit Studio Rail Lighting Hoist - Parts Identification

4 The Lighting Hoist is designed for supporting luminaires or scenery within studios or other buildings that are provided with complete weather protection and where it is guaranteed that no water will be applied to the hoist. The Lighting hoist uses pairs of wire ropes to support the pipe or rail and, if required, one or more pairs of ropes carry a folding power supply cable system to suit the travel range, while the associated outlet sockets required for luminaires are mounted above the pipe. The Scenery hoist has wire ropes attached to load attachment features. The equivalent A-weighted noise level at work stations is below 70dB(A). Each hoist includes the following components: Winding unit with electric motor and limit switches. Set of diverter units. Self folding cable system. Wire ropes. A separate pipe or Studio Rail for load carrying. An appropriate length of Unistrut P 1000 T. Socket boxes with circuit outlet sockets and interconnecting conduit. Winder The Winder unit is selected to suit voltage and frequency for the three phase supply. Variation of gearmotors can provide a choice of hoist speed. Diverter Units. The diverter unit is a device which guides the wire ropes from the Winder to the load carring Pipe/Rail. The four rope hoist has two diverters, for 6 ropes and 8 ropes there is an additional diverter for each pair of ropes. Each diverter unit is fitted with load sensing switches which monitor any slack ropes and overloadng. Wire Ropes. The pipe or rail may be suspended on 4, 6 or 8 wire ropes. These are in pairs for lighting hoists where the power cables are guided by a pair of wire ropes. Elsewhere the ropes may be in pairs or may be evenly spaced along the pipe. For 6 and 8 rope hoists a cable guide is required between the Winder and adjacent diverter to guide the wire rope correctly to the diverter beyond. Pipe/Rail length. Each hoist carries a pipe or rail for attachment of luminaires etc. The length of the pipe/rail is selected to suit each hoist according to site requirements. The load will be a be a number of luminaires and/or suspension equipments, arranged so not to exceed the evenly distributed Safe Working Load for the hoist. Mounting. The winding unit and the diverter units are designed to be suspended below a length of Unistrut type reference P 1000 T. Each hoist is supplied with the required length of Unistrut.

5 Socket boxes. The 4 rope lighting hoist can be fitted with up to 8 outlet sockets. These are normally CEE type to BS 4343 ; IEC and EN Outlets are rated at 240 volts and there is a choice of 16 or 32 amp type. Adaptor plates enable many other types of outlet to be fitted, to suit particular requirements. For four rope, 6 and 8 rope arrangements, one socket box can be provided per pair of wire ropes, while up to four sockets can be fitted to each socket box. Cable assembly. The folding cable system will include flatform cable that is either 12 ways of 13AWG/2.5mm²; or 24 ways. Other cables can also be carried such as DMX enabling a wide variety of outlets to be supplied. Rating Label The rating label identifies the hoist and lists electrical power requirements for the motor, the maximum travel dimension and the rope spacing. An example is illustrated at Appendix 2 and the label is located at the winding unit. Connections Power connections are required for the motor, and separate control connections are required for the load sensors and limit switches. Crimp connectors are provided for connection of control wiring to the hoists. The schematic circuit for each hoist is shown in Appendix 3. Control system All hoists within one studio should be controlled by one integrated control system, and this may enable selected hoists to be grouped to run together. However each hoist must be connected to an Anti-chatter circuit in accordance with Appendix 3. The anti-chatter circuit ensures that overload and slack rope inhibiters operate correctly and without chatter. The anti-chatter circuit holds the lower circuit inhibited after momentary slack rope condition, and this hold is only released by selecting raise, or by interrupting the supply. Similarly, the raise circuit is held inhibited in the event of momentary overload. SAFETY WARNING! Hoists are supplied for installation within a suitable building.it is the sole responsibility of the purchaser of the hoists to ensure that the strength of the building is adequate for the weight of fully loaded hoists, and for overload testing at 125% Safe Working Load. The purchaser of the hoists must ensure adequate structural strength for the mounting points for each hoist.

6 Contact Doughty Engineering Ltd Crow Arch Lane Ringwood, Hampshire, BH24 1NZ Tel: +44 (0) Fax: +44 (0) Web: Note: Whilst every effort has been made to ensure that the information contained within this manual is correct, Doughty Engineering does not accept any liability for errors or omissions. Specifications and technical data are intended for guidance purposes only and may vary.

User Manual. H Frames. Original Instructions. Revision

User Manual. H Frames. Original Instructions. Revision User Manual H Frames Original Instructions Revision 1.3 Contents Contents: Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Assembly Examples... 4 Assembly... 5 Couplers... 6 Extensions...

More information

User Manual. Studio Rail. Size Version

User Manual. Studio Rail. Size Version User Manual Studio Rail Size 60 Version 10.1 Contents Contents: Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Operating Data...3-8 1. Selecting the correct carriage...3-5 2. Mounting

More information

User Manual. Quick Trigger Clamps. Original Instructions Revision 2 06/10/15.

User Manual. Quick Trigger Clamps.   Original Instructions Revision 2 06/10/15. User Manual Quick Trigger Clamps Original Instructions Revision 2 06/10/15 Introduction The Quick Trigger collection is a range of aluminium clamps designed specifically to attach to round tubes or truss

More information

User Manual. Doughty Clamps/Couplers. Original Instructions Revision 3 18/02/16 - CN

User Manual. Doughty Clamps/Couplers.   Original Instructions Revision 3 18/02/16 - CN User Manual Doughty Clamps/Couplers Original Instructions Revision 3 18/02/16 - CN1287 Introduction The Doughty Coupler collection is a range of aluminium clamps/couplers designed specifically to attach

More information

Operating Manual. Pantographs. Version 05/12.

Operating Manual.   Pantographs. Version 05/12. Operating Manual Pantographs Version 05/12 Parts & Features A pantograph is a mechanical device that enables a load to be suspended by the means of balancing the load with two or more constant tension

More information

User Manual. T29870 Beam Clamp. Original Instructions. Rev /08//14.

User Manual. T29870 Beam Clamp. Original Instructions. Rev /08//14. User Manual T29870 Beam Clamp Original Instructions Rev 1.0-12/08//14 www.doughty-engineering.co.uk Contents Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Operation... 3 Maintenance...

More information

ACOUSTIC CONTAINER RANGE

ACOUSTIC CONTAINER RANGE Stuart House Crows Hall Lane Attleborough Norfolk NR17 1AD tel: 01953 454540 fax: 01953 456968 email: enquiries@stuartgroup.info web: www.stuartpower.co.uk freephone orderline: 0500 459876 ACOUSTIC CONTAINER

More information

Warning. Document ref: A October 2015

Warning. Document ref: A October 2015 Sentry Door Curtain Installation, Operation & Maintainance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hampshire, P09 2JD Tel. 023 9247 7700 Email. info@dunham-bush.co.uk Document ref: 128-000-001-A

More information

STANDARD FEATURES 3 METRE SAFEGEN. Secure fuel tank and generator store 1M 3 METRE TWINPAK

STANDARD FEATURES 3 METRE SAFEGEN. Secure fuel tank and generator store 1M 3 METRE TWINPAK STANDARD FEATURES 3 METRE SAFEGEN Secure fuel tank and generator store 65dBA @ 1M 3 METRE TWINPAK Can accommodate a P88E Day and P22E Night Generator 65dBA @ 1M 6 METRE P250 Generator 75dBA @ 1M P635 Generator

More information

USER MANUAL KLIPER BMU. All persons operating this equipment must read and completely understand this manual.

USER MANUAL KLIPER BMU. All persons operating this equipment must read and completely understand this manual. USER MANUAL KLIPER BMU All persons operating this equipment must read and completely understand this manual. Any operation in violation of these instructions is at the operator's own risk. Keep this manual

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

SELF CLIMBING HOIST Lighting Suspension

SELF CLIMBING HOIST Lighting Suspension SELF CLIMBING HOIST Lighting Suspension Mod. 8500 LIGHTING PIPE LIGHTING RAIL FEATURES SAFETY Approved by the internationally recognized testing authorities of TÜV to the German standards, the DIN 15560

More information

The Stannah Stairiser SX User Manual

The Stannah Stairiser SX User Manual 9 NOTES The Stannah Stairiser SX User Manual Make sure you understand the contents of this booklet. Keep it handy for reference. Your Stairlift Number is: Please quote this number on any correspondence

More information

Oil Seal Catalogue. Ashley Power Ltd Ashley Road Parkstone Poole Dorset, BH14 0AQ. P1

Oil Seal Catalogue. Ashley Power Ltd Ashley Road Parkstone Poole Dorset, BH14 0AQ.  P1 Ashley Power Ltd. 580-586 Ashley Road Parkstone Poole Dorset, BH14 0AQ Oil Seal Catalogue Tel: +44 (0) 1202 746031 Fax: +44 (0) 1202 741108 Email: sales@ashleypower.co.uk P1 Oil Seals P2 Oil Seals Contents

More information

ILT Italy Srl Via Cancelliera 10a Albano Laziale Rome Italy Tel Fax

ILT Italy Srl Via Cancelliera 10a Albano Laziale Rome Italy Tel Fax SELF CLIMBING HOIST LD LIGHTING SUSPENSION MOD. 8600LD, SWL 140 kg. Over Grid Version Mod. 8601LD DATA SHEET 2/7/2018 The letters in the Model Number stand for: LD Light Duty = up to 140 kg. SWL The illustration

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N. 010 848 389 trading as Power Drive Systems Generator Control Specialists 48A Ainsdale Street Telephone: 0500 800 225 P.O. Box 30 West Chermside, Qld

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed Aqua-safe Waterproof Plug & Socket Connectors Simply better designed 2 Aqua-safe Simply better designed Elkay s Aqua-safe is the only all-round solution for safely connecting and carrying power through

More information

Setup and Configuration Guide Universal Switch Interface

Setup and Configuration Guide Universal Switch Interface Table of Contents J1939 inmotion Cell Setup and Configuration Guide Universal Switch Interface Overview... 2 Warnings... 3 J1939 inmotion Cell Technical Details... 4 inmotion Cell Installation Steps...

More information

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO OPERATING INSTRUCTIONS ASTRO HOIST Type E89-CTO CONFORM TO EN 1808 - MARCH 1999 MACHINE DIRECTIVE 98/37 EC All persons operating this equipment must read and completely understand this manual. Any operation

More information

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES Sapphire Solar Pty Ltd Phone: 1300 308 751 Email: customerservice@sapphire-solar.com 4/320 Lorimer Street, Port Melbourne VIC Australia 3207 TABLE OF CONTENTS 1. ABOUT THIS MANUAL... 3 2. DISCLAIMER OF

More information

Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69)

Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69) Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69) A range of thermocouple sensors specifically designed to withstand the harsh conditions within autoclaves. Autoclave Load and Drain thermocouples

More information

Instruction Manual August milltronics MMI BELT SCALE

Instruction Manual August milltronics MMI BELT SCALE Instruction Manual August 2003 milltronics MMI BELT SCALE Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

HBDBM High Bay Series

HBDBM High Bay Series HBDBM High Bay Series INSTALLATION INSTRUCTIONS The High Bay Luminaire is ideal for installations with mounting heights over 25 feet. The fixture can be mounted with a hook or pendant with flexible adjustments

More information

CPCS renewal test factsheet

CPCS renewal test factsheet CPCS renewal test factsheet Introduction to the CPCS renewal test The industry-led CPCS Management Committee has determined that key safety-related knowledge must be checked on each category prior to the

More information

V64-V65 PLATFORM STAIRLIFTS

V64-V65 PLATFORM STAIRLIFTS V64-V65 PLATFORM STAIRLIFTS EASY TO USE COMFORTABLE & SAFE FAST DELIVERY The platform stairlifts This range of platform stairlifts provides safe access to all public and private premises. Thanks to the

More information

Patriot Portable Material Hoist 850/1000/2000. Operator s Manual

Patriot Portable Material Hoist 850/1000/2000. Operator s Manual Patriot Portable Material Hoist 850/1000/2000 Operator s Manual Manual must be read carefully by all operators before hoist is set-up and used. Failure to follow all directions and warnings for safe mounting

More information

Belt Installation Procedure

Belt Installation Procedure Rolled Baking Band Installation Guidelines Existing Belt Installation Procedure Preparation and Conveyor Checks Prior to Belt Installation Before installing a new belt, always check the conveyor structure:-

More information

INVICTUS NOISE MONITOR WINDSHIELD TECHNICAL INFORMATION

INVICTUS NOISE MONITOR WINDSHIELD TECHNICAL INFORMATION INVICTUS NOISE MONITOR WINDSHIELD TECHNICAL INFORMATION CIRRUS RESEARCH PLC Edition 1.1 OCTOBER 2016 The content of this manual, any illustrations, technical information and descriptions within this document

More information

De Sisti Automated Theatre

De Sisti Automated Theatre De Sisti Automated Theatre Stage Hoist pg. 6 DL50 Point Hoist pg. 16 Batten Hoist pg. 8 On Stage Front of House Houselight Hoist pg. 14 CH250 Point Hoist pg. 17 Lobby De Sisti Automation How De Sisti sets

More information

AGCO América do Sul (Factory Install) Installation Manual SP01

AGCO América do Sul (Factory Install) Installation Manual SP01 SP01 AGCO América do Sul (Factory Install) Installation Manual Printed in Canada Copyright 2010 by NORAC Systems International Inc. Reorder P/N: UC5-BC-SP01-INST Rev G (AGCO Brazil Factory Install) NOTICE:

More information

Installation Manual Infinity LED Light

Installation Manual Infinity LED Light Installation Manual Infinity LED Light Background This manual provides guidance on installation of the Infinity LED Linear light and associated accessories. Please contact customer support with any installation

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Position Paper. Telehandler Use: Lifting Suspended Loads

Position Paper. Telehandler Use: Lifting Suspended Loads Position Paper Telehandler Use: Lifting Suspended Loads The following paper reflects the considered opinion on the Crane Association of New Zealand (Inc.) This document has been prepared by the Technical

More information

Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19

Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19 Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19 A wide variety of thermocouples commonly used in the plastics industry, suitable for high and low temperatures applications. Available in a choice

More information

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. File: 091-56-12 rev b.pmd Rev: B, Date: 4-1-10 INSTRUCTION MANUAL AUTO CHARGE 1000 AUTOMATIC BATTERY CHARGER MODEL #091-56-12 INPUT :115 volt, 50/60 Hz, 3.5 amps OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL

More information

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe) FS3 Valves Solenoid Powered to Open / Spring to Close (failsafe) Part of the F Series of easily installed, compact, air intake valves for diesel engine emergency shut down. Application The FS3 version

More information

i-energy i-micro inverter GT260

i-energy i-micro inverter GT260 i-energy i-micro inverter GT260 This installation guide contains important instructions on safety matters and the installation of the i-energy i-micro inverter GT260. Please read this guide carefully and

More information

Cable Management System Installation Manual

Cable Management System Installation Manual Cable Management System Installation Manual TABLE OF CONTENTS 1.0 INTRODUCTION and SAFETY... 2 2.0 INSPECTION and UNPACKING... 2 3.0 GENERAL INSTALLATION... 2 4.0 UPPER MOUNTING... 5 4.1 Under Hung Loft

More information

DRAFT COPY, NOT FOR DISTRIBUTION

DRAFT COPY, NOT FOR DISTRIBUTION GENERAL INFORMATION This manual contains relevant information concerning the technical aspects of using the Mediheat MH900/12 Portable Fluid Bag Warmer, and should be read by all persons expected to operate

More information

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. 1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL

More information

Electrical Basics for Theatre

Electrical Basics for Theatre Electrical Basics for Theatre Electricity is dangerous, invisible, and potentially deadly. Treat it with respect. What is electricity? Electricity is the flow of electrons in a conductor. In many ways,

More information

Tug Compact. Operating Manual

Tug Compact. Operating Manual Tug Compact Operating Manual Tug Compact Operating Manual OM0012E/2 This manual contains important safety, installation and operating instructions for this unit. Read this manual thoroughly and completely,

More information

Manufacturer: Power Climber b.v.b.a, Satenrozen 7, B-2550 Kontich BELGIUM. Reference: E Issue date: 18-jul-2005 Revision: B Page 1 of 11

Manufacturer: Power Climber b.v.b.a, Satenrozen 7, B-2550 Kontich BELGIUM. Reference: E Issue date: 18-jul-2005 Revision: B Page 1 of 11 OPERATING INSTRUCTIONS HOIST Models: Single phase: TITAN 501 and TITAN 651 hoist with Central Control box Three phase: TITAN 503 and TITAN 653 hoist with Central Control box Conform to EN 1808 (1999) and

More information

JANDS DD-8. Technical Manual. Version 1.0

JANDS DD-8. Technical Manual. Version 1.0 JANDS DD-8 O p t o - I s o l a t e d D M X S p l i t t e r Technical Manual Version 1.0 EMC COMPLIANCE This product is approved for use in Europe and Australia/New Zealand and conforms to the following

More information

DL-300 Charge Controller User Manual

DL-300 Charge Controller User Manual DL-300 Charge Controller User Manual Tel: +44 (0)845 652 0396 Skyrrid Farm, Pontrilas, Hereford. HR2 0BW. UK www.leturbines.com Introduction Please read this manual thoroughly before attempting to assemble,

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

ASSEMBLY OF TROLLEY TO HOIST

ASSEMBLY OF TROLLEY TO HOIST INSTRUCTIONS AND PARTS LIST RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS) GENERAL Yale Rigid Mount I-Beam Trolleys are designed especially for use on

More information

OVERHEAD SERVICE. Items to consider

OVERHEAD SERVICE. Items to consider OVERHEAD SERVICE Items to consider The maximum length of the service wire from the ComEd pole to the point of attachment on your residence is 150 feet, if practical. Your service wire installation must

More information

Guidance to Installers of Viridian EV Charging Stations

Guidance to Installers of Viridian EV Charging Stations Guidance to Installers of Viridian EV Charging Stations Iss 6 - Jul 2016 Page 2 of 9 This guide is intended to instruct in the proper installation of a Viridian EV Charging Station. Please note that when

More information

Data Sheet BP v 100Ah LiFePO 4 (Peli TM Case Kit)

Data Sheet BP v 100Ah LiFePO 4 (Peli TM Case Kit) Data Sheet BP2589-12v 100Ah LiFePO 4 (Peli TM Case Kit) Product Name Battery Model Spec File Revision LiFePO4 Battery in Peli TM Case LiFePO4-11198141 4S5P 12.8V 100Ah A2 Amendment Records Revision Description

More information

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

Silent Gliss. Electric Curtain Track Systems

Silent Gliss. Electric Curtain Track Systems Electric Curtain Track Systems 2 Electric Curtain Track System Product Information For very heavy installations Exceptionally neat profile for size of system, especially compared with traditional stage

More information

CORPORATION REPAIR MANUAL HWH TOUCH PANEL-CONTROLLED LEVELING SYSTEM 310 SERIES FEATURING:

CORPORATION REPAIR MANUAL HWH TOUCH PANEL-CONTROLLED LEVELING SYSTEM 310 SERIES FEATURING: HWH R CORPORATION REPAIR MANUAL HWH TOUCH PANEL-CONTROLLED LEVELING SYSTEM 310 SERIES FEATURING: R TOUCH PANEL BI-AXIS CONTROL CENTRAL GROUNDING KICK-DOWN OR STRAIGHT-ACTING JACKS WITH OR WITHOUT AIR DUMP

More information

J1939 POWERCELL Setup and Configuration Guide Universal Switch Interface

J1939 POWERCELL Setup and Configuration Guide Universal Switch Interface Table of Contents J1939 POWERCELL Setup and Configuration Guide Universal Switch Interface Overview... 2 Warnings... 3 J1939 POWERCELL Technical Details... 4 POWERCELL Installation Steps... 5 Mounting

More information

Installation Information 2009 Model 300 Dumbwaiter

Installation Information 2009 Model 300 Dumbwaiter Installation Information 2009 Model 300 Dumbwaiter 3/17/09 Introduction This new model of Matot Dumbwaiter has several features that we hope you find are beneficial. Precision extruded rail sections provide

More information

Rogator 64 and 74 Series and Willmar Eagle 8650 (JIC) & 84, 94 & 1386 Series (Flat Faced O-Ring) Installation Manual RG2 & RG6

Rogator 64 and 74 Series and Willmar Eagle 8650 (JIC) & 84, 94 & 1386 Series (Flat Faced O-Ring) Installation Manual RG2 & RG6 RG2 & RG6 Rogator 64 and 74 Series and Willmar Eagle 8650 (JIC) & 84, 94 & 1386 Series (Flat Faced O-Ring) Installation Manual Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder

More information

SUPER CAPACITOR CHARGE CONTROLLER KIT

SUPER CAPACITOR CHARGE CONTROLLER KIT TEACHING RESOURCES ABOUT THE CIRCUIT COMPONENT FACTSHEETS HOW TO SOLDER GUIDE POWER YOUR PROJECT WITH THIS SUPER CAPACITOR CHARGE CONTROLLER KIT Version 2.0 Teaching Resources Index of Sheets TEACHING

More information

Instruction Manual August milltronics MSI BELT SCALE

Instruction Manual August milltronics MSI BELT SCALE Instruction Manual August 2003 milltronics MSI BELT SCALE Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

User Guide for Viridian EV Charging Stations

User Guide for Viridian EV Charging Stations User Guide for Viridian EV Stations Iss 3 - JULY 2015 Page 2 of 8 Thank you for purchasing a Viridian EV station. This guide is intended to instruct in the proper use of all models of Viridian stations.

More information

SILVERLINE OVERLOAD LIMITER FOR OVERLOAD SAFETY OF CRANE

SILVERLINE OVERLOAD LIMITER FOR OVERLOAD SAFETY OF CRANE SILVERLINE OVERLOAD LIMITER FOR OVERLOAD SAFETY OF CRANE Silverline Metal Engineering Pvt. Ltd., R 649, T.T.C Industrial Area, Rabale, Rabale, Navi Mumbai 400701 Phone No. 022-25692740/9323222000/7498222000

More information

Offshore Platform Leg Inspection Wolf Safety

Offshore Platform Leg Inspection Wolf Safety Hazardous Area 1 st August 2015 www.dftme.com Page 1 of 10 Contents 1 Summary... 3 2 Temporary Luminaire Configuration... 4 3 Rope Access Compatibility... 6 3.1 Alternative illumination solution... 8 4

More information

COLDWATER LAKE FACILITIES DUPLEX PUMP STATION

COLDWATER LAKE FACILITIES DUPLEX PUMP STATION COLDWATER LAKE FACILITIES DUPLEX PUMP STATION TROUBLESHOOTING GUIDE REFERENCE: Operation Instructions Ladder Schematic Diagrams SCOPE The following troubleshooting guide has been specifically prepared

More information

CPCS renewal test factsheet

CPCS renewal test factsheet CPCS renewal test factsheet Introduction to the CPCS renewal test The industry-led CPCS Management Committee has determined that key safety-related knowledge must be checked on each category prior to the

More information

RM moveit. Instruction Manual. Notebus -IC. Notebus + Notebus (LAP16-17H IC) (LAP16-17H EPM) (LAP16-17H B)

RM moveit. Instruction Manual. Notebus -IC. Notebus + Notebus (LAP16-17H IC) (LAP16-17H EPM) (LAP16-17H B) RM moveit Instruction Manual Notebus Notebus + Notebus -IC (LAP16-17H B) (LAP16-17H EPM) (LAP16-17H IC) RM moveit Instruction Manual The RM moveit (Bretford LAP16-17H) is specifically designed for the

More information

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE DIRTY WATER PUMP FOR USE WITH A 110V SUPPLY ONLY SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP210A PART NO: 7230102 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Submersible

More information

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3 EUROTHERM DRIVES Control Unit Type 5525 Product Manual Copyright Eurotherm Drives Limited 2003 All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted

More information

Safelift Overhead Runway Beams & Rolling Beam Cranes

Safelift Overhead Runway Beams & Rolling Beam Cranes Operation & Maintenance Instructions Instructions for Safe Use Safelift Overhead Runway Beams & Rolling Beam Cranes Certification Safelift overhead runway beams and rolling beam cranes are lifting appliances

More information

BROMAN MODEL 123XL PORTABLE LOAD BOX. Series 2

BROMAN MODEL 123XL PORTABLE LOAD BOX. Series 2 BROMAN MODEL 123XL PORTABLE LOAD BOX Series 2 MILLER INSTRUMENTS LTD. #1 3871 North Fraser Way Burnaby, B.C. V5J 5G6 Phone: (604) 431-8882 Fax: (604) 431-8714 Web: www.miller.bc.ca BROMAN MODEL 123XL

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 400W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO: PSV6A PART NO: 7230695 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE 400W Submersible

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

60 Series Engine Controls

60 Series Engine Controls ECU 60 Series Engine Controls Use CAUTION since you are applying 120VAC RMS to the AC Input terminals and that it is always potentially their during engine run!!! ECU is a registered trademark of Engineering

More information

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground.

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground. INSTRUCTION MANUAL FILE: 091-9-2000.P65 DATE: 4-23-2000 REV. A AUTO CHARGE 2000 PUMP-PLUS AIR COMPRESSOR / BATTERY CHARGER MODEL #091-9-2000 NOTE : This charger is designed for vehicles with dual batteries

More information

Dimmer Doubler User Manual

Dimmer Doubler User Manual Dimmer Doubler User Manual Revision A The Dimmer Doubler is protected by US patent #5,323,088. Copyright Electronic Theatre Controls, Inc. All Rights reserved. Product information and specifications subject

More information

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical

More information

Reflection. Aluminium Sectional Doors

Reflection. Aluminium Sectional Doors Reflection Aluminium Sectional Doors The Reflection aluminium sectional door features a chic round edge aluminium extrusion that can be clad with either glass or acrylic. Featuring a strong, sleek and

More information

High Bay Luminaire Series

High Bay Luminaire Series High Bay Luminaire Series INSTALLATION INSTRUCTIONS The High Bay Luminaire is ideal for installations with mounting heights over 25 feet. The fixture can be mounted with a hook or pendant with flexible

More information

Backsaver Crane Catalogue. (P) (F)

Backsaver Crane Catalogue. (P) (F) Backsaver Crane Catalogue Winches are (P) 1300 65 00 35 (F) 1800 68 68 96 sales@materialshandling.com.au Backsaver Cranes Save Your Back...Save Your Money Backsaver Crane Mark II with Extendable Boom (300kg

More information

Series A Electric Linear Actuators

Series A Electric Linear Actuators 3581650/3 IM-P358-11 CH Issue 3 Series A Electric Linear Actuators Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Maintenance

More information

WORKHOLDING SYSTEMS

WORKHOLDING SYSTEMS www.ptgworkholding.co.uk WORKHOLDING SYSTEMS INSTALLATION & PRE-LOADING INSTRUCTIONS INSTALLATION & PRE-LOADING INSTRUCTIONS Pre-load Flats Machine Drawbar M/C Spindle Pre-load Adjustment Screw Mandrel

More information

Central Battery Systems

Central Battery Systems Central battery system based emergency lighting is ideal for medium to large installations. For projects where central control and testing is desirable, a central battery system is a viable and cost effective

More information

Spray Height Controller

Spray Height Controller Spray Height Controller JD10 John Deere (4930) with Proportional Main Lift Installation Manual Printed in Canada Copyright 2009 by NORAC Systems International Inc. Reorder P/N: UC5-BC-JD10-INST Rev G (John

More information

PRISM MEDICAL UK SA160C STAND AID

PRISM MEDICAL UK SA160C STAND AID PRISM MEDICAL UK SA160C STAND AID USER GUIDE Unit 1, Tir Llwyd Industrial Estate, St Asaph Avenue, Kinmel Bay, Nr Rhyl, Conwy, LL18 5JZ info@prismmedical.co.uk Tel +44 (0)1924 840100 www.prismmedical.co.uk

More information

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose OEM Emergency Portfolio Product Guide Emergency components for LED, fluorescent and auxiliary purpose Contents Introduction to this guide 3 LED Modules 4 PHL-EL3 PHL-EL3-80 PHL-EL3-D PHL-EL3-D80 PHL-EL3-4

More information

MSI SINGLE IDLER BELT SCALE

MSI SINGLE IDLER BELT SCALE MSI SINGLE IDLER BELT SCALE Instruction Manual PL-319 January 2001 33453190 Rev. 1.2 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

AV-W. Wind Speed and Wind Speed & Direction Sensors

AV-W. Wind Speed and Wind Speed & Direction Sensors Page 1 of 5 AV-W Wind Speed and Wind Speed & Direction Sensors Features: Benefits: Supplied with mounting bracket Wind speed accuracy ±2% Anodized aluminum housing Ideal for naturally ventilated building

More information

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER BOOK# 091-12HO-1 INSTRUCTION MANUAL AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER MODEL #091-12HO-PIM NOTE : This charger is designed for vehicles with a single battery system INPUT :115 volt, 50/60 Hz,

More information

ELECTRIC SERVICE REQUIREMENTS FOR MEDIUM-SIZED COMMERCIAL INTERCONNECTED DISTRIBUTED GENERATION SOURCES

ELECTRIC SERVICE REQUIREMENTS FOR MEDIUM-SIZED COMMERCIAL INTERCONNECTED DISTRIBUTED GENERATION SOURCES ELECTRC SERVCE REQUREMENTS FOR 1. Purpose These electric service requirements include information and criteria for use by TEP/UES employees and customers in regard to the interconnection and parallel operation

More information

Demag energy chain systems. Innovative solutions for radio-controlled Demag standard cranes

Demag energy chain systems. Innovative solutions for radio-controlled Demag standard cranes Demag energy chain systems Innovative solutions for radio-controlled Demag standard cranes Demag energy chain systems improved cable protection, reduced wear 40554-70 To protect power-supply and control

More information

Moving and Handling Solutions

Moving and Handling Solutions Ceiling Track Hoist Wispa Moving and Handling Solutions Made in the UK Wispa Hoist Range Moving and handling solutions for home, leisure and caring environments Healthcare providers have been working towards

More information

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS MARTINDALE ELECTRIC Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web:

More information

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016 DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all

More information

MIC210 Electric Farm Conversion Instructions

MIC210 Electric Farm Conversion Instructions MIC210 Electric Farm Conversion Instructions Note: Apply the supplied Dielectric Lubricant to all wire connections when each wire is hooked up. The Dielectric Lubricant will help to prevent corrosion.

More information

SPECIFICATION FOR. MAINTENANCE OF POWERED LIFTING PLATFORMS (for use by disabled persons)

SPECIFICATION FOR. MAINTENANCE OF POWERED LIFTING PLATFORMS (for use by disabled persons) SPECIFICATION FOR MAINTENANCE OF POWERED LIFTING PLATFORMS (for use by disabled persons) INDEX MAINTENANCE REPORTS MANUFACTURER S REQUIREMENTS PERMIT TO WORK CERTIFICATION GUIDANCE MINOR REPAIRS Platform

More information

Lifting device for standard removable versions

Lifting device for standard removable versions Operating manual Lifting device for standard removable versions Type 1889 haacon hilft heben haacon hebetechnik gmbh Josef-Haamann-Str. 6 D-97896 Freudenberg/Main Tel: +49 (0) 93 75/84-0 Fax: +49 (0) 93

More information

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES EFFECTIVE: September 25, 2007 Owner s Manual ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES 2 Ton through 20 Ton Capacity Product Code and Serial Number WARNING This equipment should not be installed,

More information