Operating Instructions SKC Inc. 863 Valley View Road Eighty Four, PA USA

Size: px
Start display at page:

Download "Operating Instructions SKC Inc. 863 Valley View Road Eighty Four, PA USA"

Transcription

1 Operating Instructions SKC Inc. 863 Valley View Road Eighty Four, PA USA Form #37740 Rev 0806

2 Table of Contents Description...1 Performance Profile...2 Battery Operation Installing the Battery Pack...4 Charging the Battery Pack...4 Battery Charge Level Indicator...5 Replacing the Battery Pack...5 Battery Eliminator...6 Introduction Pump Display...7 Keypad Basics...8 Pump Activation...8 Pump Operating Modes...9 Setup Verifying Battery Charge Level...10 Entering and Navigating the User Interface...10 Using User Interface - Level One...10 Using User Interface - Level Two...11 Resetting Run Time Data...12 Setting Pump Flow Rate...12 Setting Sampling Time...13 Setting a Delayed Start...14 Deleting a Delayed Start...14 Deleting a Sampling Time...15 Deleting a DataTrac 2000 Program...15 Calibration Flow Rate and Volume Display...16 Verifying Flow Rate Using a Primary Standard...16 Calibrating Using CalChek...18 CalChek Error Chart...22 Calibrating for Low Flow (5 to 500 ml/min) Sampling Applications...23 Sampling Sampling (1000 to 3250 ml/min)...24 Low Flow Sampling (5 to 500 ml/min)...24 Flow Fault...25 Maintenance Replacing the Inlet Port Housing and Filter...26 Service Policy...27 Accessories...28 DataTrac 2000 Software...30 UL Certificate...31 Warranty...32 Index...33 Indicates a reminder or note. Indicates a warning or caution. Notice: This operating instruction may not address all safety concerns (if any) associated with this product and its use. The user is responsible for determining and following the appropriate safety and health practices and regulatory limitations (if any) before using the product. The information contained in this document should not be construed as legal advice, opinion, or as a fi nal authority on legal or regulatory procedures.

3 AirChek 2000 Quick Guide Operation Star Button Scrolls through run time data, display options, and sampling parameters during pump setup Up and Down Arrow Buttons Increase or decrease sampling parameters and toggle between display choices in setup Button Sequence = press buttons individually [ ] = press simultaneously when bracketed = security code, always press in sequence Security Code Must be pressed within 10 seconds of previous command Pump Activation Press any button. Mode Change Press [ ] to toggle between Run and Hold. Pump Setup Options User Interface Level One Set Up Flow Rate To enter fl ow rate setup, pump must be in Hold. Press [ ] to Run pump and press within 10 seconds. Change and calibrate flow rate: Flow rate and SET fl ash. Press or to change fl ow rate. Press when fi nished; ADJ displays and fl ashes. Press or to adjust the fl ow until pump and calibrator agree. When fi nished, press until End displays. Press [ ] to save new setting. User Interface Level Two Set Up Sampling and Display To enter sampling and display setup, pump must be in Run. Press [ ] to Hold pump and press within 10 seconds. Select from the following options: Clear accumulated data: Press until CLr displays and then press [ ]. Press until End displays and then press [ ]. Change temperature scale (F/C): Press until temperature displays. Press or to switch units. Press until End displays and then press [ ] to save new setting. Change atmospheric pressure scale (mm Hg/ins Hg/millibars): Press until pressure displays. Press or to switch units. Press until End displays and then press [ ] to save new setting. Change time scale (12 Hr/24 Hr): Press until 12 Hr or 24 Hr displays. Press or to switch units. Press until End displays and then press [ ] to save new setting. Change time of day: Press until time displays. Press or to change fl ashing hour. Press to move to minutes and press or to change. Press until End displays and then press [ ] to save new setting. Change sampling time: Press until SГ 00 displays. Press or to change fl ashing digits. Press until End displays and then press [ ] to save new setting. To exit without saving changes in User Interface Level Two, scroll to Esc and press [ ].

4 Description The SKC AirChek 2000 Pump is an advanced programmable sample pump that combines lightweight compact design, computer-compatible circuitry, and a patented* isothermal flow sensor. AirChek 2000 can be used with optional DataTrac 2000 Software and your PC to expand pump programmability and recordkeeping options. The result of extensive research and development, the AirChek 2000 Pump exemplifies SKC s commitment to quality and innovation in air sampling equipment. * U.S. Patent No. 5,892,160 Inlet Port with Protective Filter Battery Status Icon Flashing LED Run Indicator Liquid Crystal Display (LCD) Keypad with Operating Buttons Battery Pack Not shown: Beltclip (back) Battery Charging Jack (back) Computer Interface Port (back) AirChek 2000 shown at 75% of actual size 1

5 Performance Profile Flow Range: Compensation Range: 1000 to 3250 ml/min (5 to 500 ml/min requires optional low fl ow adapter kit) 3000 ml/min at 15 inches water back pressure 2000 ml/min at 30 inches water back pressure 1000 ml/min at 30 inches water back pressure Typical Back Pressure of Sampling Media (inches water) Flow Rate (L/min) Filter/Pore Size (μm) 25-mm MCE, mm MCE, mm MCE, mm PVC, Compare the information in this table to pump compensation range to determine appropriate applications. Accuracies: Timing: 1 min/month at 25 C Atmospheric Pressure: ± 0.3 ins Hg Flow Rate: ± 5% of set-point after calibration Battery Charge Level Indicator: Icon displays at full, mid, and low charge (see page 5) Temperature Range: Operating: 32 to 113 F (0 to 45 C) Charging: 32 to 113 F (0 to 45 C) Storage: -4 to 113 F (-20 to 45 C) Protect sample pump from weather when in use outdoors. Altitude: Run Time: Sampling Time (SГ) Setting: Time Display: Volume Display: Do not use pump beyond 7500 ft With battery pack, run time is 10 hours at 2000 ml/min and up to 30 inches water back pressure; dependent on sample media used. See Table 1. AirChek 2000 sampling time can be set up to 999 minutes from the pump keypad or up to 30 days (43,200 minutes) from a PC using DataTrac 2000 Software. During sampling, the pump LCD will display remaining run time (will count time down from a set number of minutes) when sampling time is set from the keypad. The pump LCD will show elapsed time in minutes when the pump is programmed from a PC. If run time is longer than 9999 minutes (6.8 days), the sample time displayed on the LCD will roll over to 1 after reaching Time of day in hours and minutes (12 or 24-hour clock) with AM and PM indicators Continually updated, based on corrected fl ow rate multiplied by sampling time 2

6 Performance Profile Flow Fault: Battery Pack: Charge Time: Size: Weight: RFI/EMI Shielding: Intrinsic Safety: If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault mode. During flow fault, the pump HOLDs, the fault icon appears on the display during the length of the fault, and the accumulated run time display is frozen and retained. After 5 minutes in fl ow fault, auto-restart is attempted every 5 minutes up to 10 times. Removable rechargeable 4-cell NiCad battery pack, 4.8 V, 2.0-Ah capacity. 6 hrs using PowerFlex Charger 5.6 x 3 x 2.3 in (14.2 x 7.6 x 5.8 cm) 22 oz (624 gm) RFI/EMI-shielded case, CE marked UL and cul Listed Use only SKC-approved parts to ensure reliable performance and to maintain the UL Listing for intrinsic safety and the SKC warranty. Table 1. AirChek 2000 Run Time in Hours with NiCad Battery Following are typical run times achieved when using a fully charged Nickel- Cadmium (NiCad) battery pack. Data is sorted by type of sample media. All run times are listed in hours. Mixed Cellulose (MCE) filter, 0.8-μm pore size Filter Diameter Flow Rate (L/min) 37 mm 25 mm ** Polyvinyl Chloride (PVC) filter, 5.0-μm pore size Filter Diameter Flow Rate (L/min) 37 mm 25 mm ** Filter back pressure exceeded pump capability during testing Increases in back pressure during sampling due to buildup of sample on the filter can decrease battery life. 3

7 Battery Operation Installing the Battery Pack To enhance battery life, SKC ships battery packs separate from the pump. Once installed, completely charge battery pack before operating pump. 1. Carefully align the battery jack on the battery pack with the battery terminal on the bottom of the pump base plate and push the battery pack into place. 2. Insert and tighten two security screws provided. 3. Charge battery completely before operating pump (see Charging the Battery Pack). Charging the Battery Pack Ensure the pump is not running. Do not operate pump while charger is attached. To charge the battery, insert the charging plug from the charger into the battery charging jack on the back of the pump. Plug the charger into a standard wall outlet. The PowerFlex Charger will fully recharge the battery in 6 hours (see Accessories on page 28 for charger). Follow charger instructions. Using a non-approved charger voids the SKC warranty. Tampering with the battery pack voids the SKC warranty and the UL Listing for intrinsic safety. Do not charge or operate pump from charger in hazardous locations. Ensure that the computer interface port is covered before and during charging. Computer Interface Port Battery Charging Jack Ensure proper orientation of charging cable before plugging it into the charging jack. Improper orientation/contact will shortcircuit the battery. See photo at right. Note the keyed side of the charging cable plug must mate with the keyed side of the pump charging jack. Inserting the plug does not take much force. If force is required, the plug is not properly oriented. Short-circuiting the battery pack will render it immediately inoperative. 4

8 Battery Operation Battery Charge Level Indicator Three bars indicate a full charge (normally appears after charging), approximately 75 to 100%. Two bars indicate that the battery is charged enough to operate the pump, approximately 25 to 75%. One bar indicates battery charge is low (charge battery), approximately 1 to 25%. Low Battery Fault No bars and a flashing outline indicate a Low Battery Fault (pump will go into HOLD, and then SLEEP mode in 10 seconds). Run time data can be displayed by pressing any button. The pump will return to SLEEP in 10 seconds. This may be repeated. When the pump stops due to a low battery and is left to stand for a period of time, one battery bar may appear. This false recovery will fall quickly if the pump is operated without recharging it. RECHARGE THE PUMP BEFORE SAMPLING. Replacing the Battery Pack Battery Replacement Notes: To retain pump history, ensure the pump has been allowed to go to SLEEP after the last run. Pump history will be lost if the battery pack or AC power (battery eliminator) is removed while the pump is running. SKC recommends that data be downloaded to a PC using DataTrac 2000 Software prior to removal of the battery or power. The first 8 program steps will be retained in memory. Programs should be reloaded using DataTrac 2000 Software after replacing the battery pack. 1. Release the battery pack by removing the two security screws located on the bottom of the battery pack. Pull the battery pack away from the pump body. 5

9 Battery Operation 2. Carefully align the battery jack on the replacement battery pack with the battery terminal on the bottom of the pump base plate and push the battery pack into place. Battery terminal Pump base plate 3. Replace and tighten the two security screws removed in Step 1. Battery jack Battery pack Use of a repaired or rebuilt battery pack voids the SKC warranty and the UL Listing for intrinsic safety. Do not charge or operate the pump from the charger in hazardous locations! Use only an SKC-approved charger and battery pack designed for the AirChek 2000 Sample Pump to ensure reliable performance and to maintain the UL Listing for intrinsic safety and the SKC warranty. Use of any device other than the approved battery pack to power the pump voids the UL Listing for intrinsic safety. For more information on battery care and maintenance, go to Battery Eliminator The Battery Eliminator is an accessory that converts alternating current (AC) to direct current (DC) from which the pump can operate indefinitely. The Battery Eliminator should be used in non-hazardous locations only. See page 28 for ordering. To use the Battery Eliminator, the battery pack must be removed from the pump (see Replacing the Battery Pack on page 5). The Battery Eliminator is comprised of two pieces, (1) a wall cube that converts AC voltage to DC voltage and (2) a power adapter that reduces DC voltage. The wall cube fits into a standard wall outlet and its plug end is inserted into the power adapter. The power adapter is fitted on the pump in place of the battery pack. Use the battery eliminator to operate the pump in non-hazardous locations only. Use of any device other than the approved battery pack to power the pump voids the UL Listing for intrinsic safety. 6

10 Introduction Pump Display AirChek 2000 LCD shown at 100% HOLD: Flashes when the pump is in HOLD mode (see page 9) SГ or S: VOL: SET: CLr: ESC: End: Displayed when a sampling time is manually programmed into pump memory (see page 13) Volume of air pumped Flashes when changing any setting User Interface option that clears volume and run time data (see page 12) User Interface Level Two option that exits User Interface without saving changes (see page 12) User Interface option that saves changes and exits User Interface (see page 12) ADJ: Displayed during pump fl ow calibration (see page 11) CAL: FLOW: User Interface option that allows pump to be set up for single or multiple-point calibration using the CalChek feature (see page 11) Appears when fl ow rate is displayed PROG: Displayed when a delayed start or a DataTrac 2000 program is loaded into pump memory Display Icons Flow Fault: Flashes during fl ow fault (see page 9) Battery Charge Level: Shows battery charge level (see page 5) 7

11 Introduction Keypad Basics The AirChek 2000 Pump operates by pressing various button sequences on the keypad located on the front of the pump housing. Up arrow button Button Down arrow button AirChek 2000 Keypad shown at 100% [ ] Scrolls through run time data, display options, and sampling parameters during pump setup Increases values and toggles between options Decreases values and toggles between options When pressed simultaneously, displayed item is selected or entered. Security code that must be pressed in sequence within 10 seconds after mode change to enter the User Interface. If the 10-second time limit is exceeded, the pump will remain in its current mode. Perform steps again to enter the User Interface (see Entering and Navigating the User Interface on page 10). Pump Activation Press any button firmly to activate the LCD. Press [ ] to run the pump or to place a running pump in HOLD. Auto OFF switches pump to SLEEP after five minutes in HOLD with no activity. 8

12 Introduction Pump Operating Modes RUN Pump is running; run time data is continuously updated in memory. The LCD shows real-time run time data. Press to scroll through the parameters. Run time and volume stored in memory will continue to accumulate unless reset (see page 12). To change the pump from HOLD to RUN, press [ ] HOLD Pump is off and run time data is stored. Run time data readings are retained and displayed on the LCD. To change the pump from RUN to HOLD, press [ ] SLEEP After five minutes in HOLD, the pump automatically enters SLEEP. The LCD shuts down and the electronic circuitry enters a low-power state. Press any button to change pump from SLEEP to HOLD Flow Fault If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault mode. During flow fault, the pump HOLDs, the fault icon appears on the display during the length of the fault, and the accumulated run time display is frozen and retained. As part of the flow fault feature, the pump attempts to restart sampling after five minutes in flow fault and continues to attempt a restart every five minutes thereafter until the restricted flow is corrected or the pump has attempted a maximum of 10 restarts. The maximum number of restart attempts may be changed using a PC and DataTrac 2000 Software. 9

13 Setup Verifying Battery Charge Level The LCD displays an icon that shows the current battery charge level (see Battery Operation on page 5). A new battery should be fully charged before operation. Entering and Navigating the User Interface The AirChek 2000 User Interface features two levels: Level One Set Up Flow Rate allows the user to change flow rate, adjust flow rate to a primary standard, or calibrate the pump using the CalChek feature. Level Two Set Up Sampling and Display permits the user to change display options of temperature (F or C) and atmospheric pressure (ins, m, or mm), set a sampling time, set 12 or 24-hour clock or delayed start, set real-time clock, or clear accumulated run time data. Entering: With pump in HOLD, press [ ] to place pump in RUN and enter within 10 seconds. You are in Level One of the User Interface. With pump in RUN, press [ ] to place pump in HOLD and enter within 10 seconds. You are in Level Two of the User Interface. Navigating: Press to scroll through parameters. Once LCD shows End, parameters will repeat until the user exits the User Interface. Exiting: Press until End appears on the LCD. Press [ ]. Any changes made to parameters will be saved and the pump will continue in its current mode. Level Two of the User Interface offers the option of exiting without saving changes to parameters. Press until ESC appears on the LCD. Press [ ]. Using User Interface - Level One Flow Set Set flow by pressing to increase or to decrease pump flow rate. Press to move to next parameter or the User Interface can be exited by continuing to press until End appears. Press [ ] to save new flow setting and exit. See page

14 Setup ADJ CAL Used during calibration with primary standard calibrator (not for use with CalChek feature). Press to increase or to decrease flow adjustment until desired flow is indicated on an attached primary standard. Press to move to next parameter or the User Interface can be exited by continuing to press until End appears. Press [ ] to save new flow and adjustment settings and exit the User Interface. See page 16. Use for CalChek calibration feature only. Press [ ] to initiate singlepoint calibration. Press seven times to start a full calibration. See CalChek Calibration instructions on pages 18 to 22. Using User Interface - Level Two Temperature Atmospheric Pressure Sample Time (SГ) Press or to toggle between Fahrenheit (F) and Celsius (C). Press to move to next parameter. Press or to toggle through inches of mercury (ins), millimeters of mercury (mm), and millibars (m). Press to move to next parameter. Program a specific run time. Press to increase or to decrease the time in minutes (from 1 to 999). Press to move to the next parameter. Sample Time is not an option when a DataTrac 2000 program is loaded into pump memory (PROG). See page hr/24-hr Clock and Press or to toggle through Delayed Start standard (12-hour) time, military (24-hour) time, and delayed start (dela). See Setting a Delayed Start on page 14. Press to move to next parameter. 11

15 Setup Time of day CLr The hour will flash. Press to increase and to decrease hour. Press to advance to minutes. Once minutes are flashing, press to increase or to decrease minutes. Press to move to next parameter. Press [ ] to reset accumulated run time and volume from pump memory to zero. See below. ESC Press [ ] to exit User Interface Level 2 without saving changes to parameters. End Press [ ] to save changes to parameters and exit User Interface. OFF Appears only when a DataTrac 2000 program or delayed start is loaded in pump memory. When OFF displays, press [ ] to delete and exit the User Interface. See page 14. Resetting Run Time Data To reset accumulated volume and run time data to zero, enter User Interface Level Two by placing a running pump in HOLD and pressing within 10 seconds. Press until CLr appears on the LCD. Press [ ] to clear the run time data. Press until End appears, and then press [ ]. The pump is now in HOLD. CLr does not clear previously set sampling time (SГ). See Deleting a Sampling Time on page 15. Setting Pump Flow Rate 1. With the pump in HOLD, press [ ] to run the pump and enter within 10 seconds. You are now in User Interface Level One. 2. The flow rate on the LCD will flash. Press to increase flow or to decrease flow until the desired flow rate is displayed. 3. Press repeatedly until End appears on the LCD. 4. Press [ ] to save the flow rate and exit the User Interface. 5. Press [ ] again to place the pump in HOLD if desired. 12

16 Setup Setting Sampling Time (S Г) Program the AirChek 2000 from the keypad to run STEL, TWA, or any other run time from 1 to 999 minutes*. AirChek 2000 sampling time may also be programmed from a PC using DataTrac 2000 Software*. To program a sampling time using the pump keypad: 1. With the pump running, press [ ] to place the pump in HOLD and enter within 10 seconds. You are in User Interface Level Two. 2. Repeatedly press until SГ and a flashing 00 appear on the display. 3. Set the sampling time by pressing to increase it or to decrease it to the desired time in minutes. 4. Press repeatedly until End appears. 5. Press [ ] to save the sampling time and exit the User Interface. A flashing S will appear with the selected sampling time on the LCD. 6. Press [ ] to begin sampling. The time display will count down, the pump will go into HOLD, and the total sampling time will display when sampling is complete. 7. To delete a set sampling time, enter User Interface Level Two, scroll to SГ, and press until time appears as 00. Exit the User Interface by scrolling to End and pressing [ ]. If a time still displays after canceling a sample time, this display is the total run time since the data was last reset. If a sampling time (SГ) has been programmed into the pump, a DataTrac 2000 program cannot be entered without deleting the sampling time first (see page 15). Likewise, if a DataTrac 2000 program resides in pump memory, the sampling time (SГ) function cannot be selected until the DataTrac program is deleted (see page 15). * Sampling Time (SΓ) Setting: AirChek 2000 sampling time can be set up to 999 minutes from the pump keypad or up to 30 days (43,200 minutes) from a PC using DataTrac 2000 Software. During sampling, the pump LCD will display remaining run time (will count time down from a set number of minutes) when sampling time is set from the keypad. The pump LCD will show elapsed time in minutes when the pump is programmed from a PC. If run time is longer than 9999 minutes (6.8 days), the sample time displayed on the LCD will roll over to 1 after reaching

17 Setup Setting a Delayed Start The Delayed Start feature is available in pump version 2.59 or higher. When setting the pump manually for sampling to begin within a 12-hour timeframe, follow this procedure: 1. With the pump running, press [ ] to place the pump in HOLD and enter within 10 seconds. You are in User Interface Level Two. 2. Press until SГ appears. Press or to set a sample time. This is required to set a delayed start. 3. Press until the display reaches the 12-hr/24-hr clock. Press or until the display shows a flashing dela (delayed start). 4. Press. Time will display with hours flashing. Press to increase or to decrease the hour. Press to move to minutes. Press to increase or to decrease the minutes. The time entered here will be the next occurrence of this time. There is no a.m. or p.m. designation. 5. Press until End appears. 6. Press [ ]. 7. The PROG icon and a flashing HOLD will appear in the upper left corner of the display. The pump is now set for delayed start. If setting a delayed start using DataTrac 2000 Software, refer to the DataTrac 2000 Operating Instructions (included on the software CD). A programmed delayed start can be viewed in the DataTrac 2000 Scheduler. Deleting a Delayed Start This is the same method used to delete a DataTrac 2000 program from the pump (see Deleting a DataTrac 2000 Program on page 15). 1. With the pump running (will only run in short bursts), press [ ] to place the pump in HOLD and enter within 10 seconds. You are in User Interface Level Two. 2. Press to scroll to the flashing OFF indicator and press [ ]. 3. Press until End displays. 4. Press [ ]. The PROG icon should be gone. If not, repeat process until it disappears. 14

18 Setup Deleting a Sampling Time (SГ) To delete a sampling time, enter User Interface Level Two and press the button to scroll to SГ. Press until SГ 00 appears. Press the button until End appears. Press [ ]. Deleting a DataTrac 2000 Program If a DataTrac 2000 program is in pump memory, the PROG icon will appear in the upper left corner of the display. To delete a DataTrac 2000 program, enter User Interface Level Two, scroll to the flashing OFF indicator, and press [ ]. This is the same method used to delete a delayed start from the pump. See Deleting a Delayed Start on page

19 Calibration Flow Rate and Volume Display Flow rate displayed on the pump LCD is the flow to which the pump has been calibrated. To maintain flow as displayed, the pump automatically adjusts flow during sampling for changes in temperature and atmospheric pressure that may differ from the temperature and atmospheric pressure present at the time of calibration. The flow rate display does not change from the calibrated flow rate. The pump will fault if it is unable to maintain the calibrated flow rate. Volume displayed on the pump LCD is corrected in that it is the result of a continual calculation of corrected flow rate multiplied by sample time. Verifying Flow Rate Using a Primary Standard 1. Connect the pump inlet to the outlet of the representative sampling medium using flexible tubing. To ensure sample integrity, tubing seals tightly onto the pump inlet filter cover. Use care when removing tubing to prevent cracking or breakage of the inlet filter cover. 2. Connect the inlet of the sampling media to a primary standard calibrator using another length of flexible tubing. 3. From HOLD, press [ ] to run the pump and enter within 10 seconds. You are in User Interface Level One. SET flashes on the LCD. 4. The LCD will display a flashing flow rate from the last sample taken. If you do not wish to change the flow rate go to Step Press to increase the flow rate or to decrease the flow rate to the desired setting. 6. Press. The flashing ADJ appears on the LCD, replacing the flashing SET. The pump flow rate can now be calibrated using a primary standard calibrator. The flow rate displayed on the calibrator will change as a result of this adjustment, not the flow rate displayed on the pump. The pump will display an adjustment factor (ADJ) only. 7. Compare the flow rate from the primary standard to that displayed by the pump. If the calibrator indicates a higher flow rate than the pump, press until the pump and calibrator are in agreement (within 10 ml). If the calibrator indicates a lower flow rate than the pump, press until the pump and calibrator are in agreement (within 10 ml). 16

20 Calibration 8. Press until End appears on the LCD. Press [ ] to save flow setting and exit the User Interface. The pump will remain in RUN. Reset run time data (see page 12). 9. Place pump in HOLD by pressing [ ]. Disconnect the calibration train. Pressing [ ] will place a running pump in HOLD, and a holding pump in RUN. If a delayed start or DataTrac 2000 schedule has been programmed into the pump, it may remain in pump memory. PROG will display in the upper left corner of the pump display. To delete this program, enter User Interface Level Two, scroll to the flashing OFF, and press [ ]. 17

21 Calibration Calibration Using the CalChek Automatic Calibration Feature The CalChek automatic calibration feature is available when calibrating an AirChek 2000 Pump with a Defender Calibrator (Cat. No M). A CalChek Communication Cable (Cat. No ) is required. Optional DataTrac 2000 Software can be used to expand the documentation capabilities of this system. The CalChek feature provides two calibration options: singlepoint calibration allows setting and verifying a flow rate at a single point before and after sampling. Multiple-point (full) calibration corrects flow to a primary standard at multiple flow rates to cover the basic operational flow range of the pump. Both types of calibration bring flow to within 5%. If using a pump version below 2.59, a pump upgrade is required for the CalChek feature. Contact SKC. Do not perform single-point or multiple-point calibration until the pump has remained at ambient temperature for several hours. Single-point Calibration Using CalChek The CalChek feature provides correction at a single flow setting and takes less than one minute to complete. Use it to set the desired flow rate before sampling and to verify flow after sampling. 1. Use 1/4-inch tubing to connect the Defender Calibrator suction port to the inlet of a representative sampling medium and the outlet of the medium to the AirChek 2000 pump inlet. 2. Run the pump for 2 minutes before starting calibration. Leave the pump on. 3. Select the Defender data port: a. Press and hold the Defender power button to turn on the calibrator. b. Press the right arrow to highlight Setup; press Enter. c. Press the right arrow to highlight Preferences; press Enter. d. Press the down arrow to navigate to Data Port. e. Press the left or right arrow to toggle to SKC. f. Press the down arrow to highlight Confirm; press Enter. 4. Enter Defender calibration mode: a. Press the right arrow and then the down arrow to highlight Measure; press Enter. b. Press the right arrow to highlight Cont.; press Enter. 5. Attach the female end of the CalChek Communication Cable to the serial port (RS-232) on the back of the Defender Calibrator. 18

22 Calibration 6. Insert the male end of the CalChek Communication Cable into the data port on the pump. 7. Place the pump in HOLD by pressing [ ]. Press [ ] again to start the pump running, and enter the security code in sequence on the pump keypad within 10 seconds. You are in User Interface Level One. 8. Press or to set the pump to the desired flow rate. 9. Press on the pump keypad until CAL appears on the pump display. 10. Press [ ] to select single-point calibration CAL will appear on the pump display. During calibration, the pump will display briefly the flow rates that it is reading from the calibrator. 12. When calibration is complete, the pump display will either show End indicating a successful calibration, or it will show an error code of E4[x] (see CalChek Error Chart on page 22). Note: To remove a CalChek error code from the LCD, press. 13. Press [ ] twice to place the pump in HOLD. Disconnect the pump from the representative sampling medium and the calibrator. To ensure sample integrity, tubing seals tightly onto the pump inlet filter cover. Use care when removing tubing to prevent cracking or breakage of the inlet filter cover. 14. Allow pump to go to SLEEP. Data does not write to memory until pump has gone into SLEEP mode. Successful single-point calibration will provide an entry in the pump history that can be viewed using DataTrac 2000 Software (v or higher). If used with earlier DataTrac 2000 versions, the entry will appear as an undecipherable code; update DataTrac 2000 Software. If an error occurs during calibration, the event will not be stored in history. 19

23 Calibration Full (Multiple-point) Calibration Using CalChek This type of calibration provides flow correction across the basic operating range of the AirChek 2000 pump (750 to 3000 ml/min) in approximately 4 minutes. The operation calibrates each flow rate to a primary standard. It can also provide a record of calibration for maintenance and quality purposes if DataTrac 2000 Software is used. SKC recommends that a full calibration be performed during pump maintenance and after non-factory repairs. Full calibration clears history, run time parameters, and the Scheduler in DataTrac 2000 Software. Do NOT place sampling media in line for full calibration. Ensure the battery pack is completely charged before starting a full calibration. Do not perform single-point or multiple-point calibration until the pump has remained at ambient temperature for several hours. 1. Use 1/4-inch tubing to connect the Defender Calibrator suction port to the AirChek 2000 pump inlet. Do NOT place sample medium in line. 2. Run the pump for 2 minutes before starting calibration. Leave the pump on. 3. Follow Steps 3 through 9 from Single-point Calibration Using CalChek on pages 18 and Verify that the battery icon on the pump display shows at least two bars. If it does not, charge the battery before proceeding. 5. Press on the pump keypad 7 times to place pump in full calibration mode. 6. The Defender Calibrator will begin to automatically calibrate the pump. Initial flow measurements are taken without flow from the pump and the pump flow rate is adjusted automatically. The pump will display FCAL, CS1, and a brief flow rate. The pump will continue to display CS2, then a flow rate, CS3, then a flow rate, etc. until calibration is completed at all flow rates between 750 and 3000 ml/min. Full calibration begins at flows lower than 750 ml/min. At these lower flow rates, the calibrator piston will move slowly. This is normal; do not interrupt calibration. CalChek full calibration can be aborted by pressing [ ]. The pump will go to HOLD. 20

24 Calibration 7. When calibration is completed, the pump will go to HOLD. If the calibration was successful, the pump LCD will revert to displaying pump run time as 0. If there was failure during the calibration process, an error code of E4[x] will appear (see CalChek Error Chart on page 22). Note: To remove a CalChek error code from the LCD, press. 8. Allow the pump to go to SLEEP mode to write calibration data to pump memory. Data does not write to pump memory until pump has gone into SLEEP mode. CalChek Full Calibration Data Full calibration data can be viewed and printed by going to the DataTrac 2000 Pump Manager window and clicking on the View menu. Choose Calibration Info. This will display calibration results, pump serial number, and date of the last full calibration. A button allows this data to be printed. The printed report contains pump version, date printed, and a validation code. CalChek Calibration Data Verification in DataTrac 2000 Software This feature requires pump version 2.62 or higher and DataTrac 2000 Software version 3.62 or higher. To ensure that printed data has not been tampered with, pull down the Tools menu and choose Confirm Validation Code. Enter the data from the printed report, including the validation code. DataTrac 2000 will indicate whether the information is completely valid or if a parameter has been changed. Clearing the history will not clear full calibration data. This data can only be cleared by performing another full calibration or by obtaining more than 36 pump history records. When entering data to confirm the validation number, enter the date in the following format: mmm dd, yyyy (e.g., Aug 18, 2008) 21

25 Calibration CalChek Error Chart Single-point Calibration Errors Error Problem Troubleshooting E41 Correction required too large. A Perform a full calibration. If this fails mismatch of greater than 360 ml/min contact SKC Technical Support. between the fl ow setting on the pump and the reading generated by the Defender Calibrator has occurred. E48 Could not get a successful single point Try the calibration again. If problem calibration within fi ve fl ow readings. persists, perform a full calibration. Full (Multiple-point) Calibration Errors Error Problem Troubleshooting E44 First fl ow reading greater than 750 Check tubing between pump s upper ml/min. The pump is fl owing faster pressure sensor and the top valve than it should, even though the assembly diaphragm to ensure it is not calibration routine delivered only a pinched or blocked, or contact SKC very small voltage to the pump. Technical Support. E45 Pump unable to achieve fl ow rate of Check pump s fl ow tube to ensure 3000 ml/min possibly due to a blocked it is not blocked, or contact SKC fl ow tube or an air leak inside the pump. Technical Support. E46 Analysis error in the data (rare). Try full calibration again. If problem persists, contact SKC Technical Support. E47 Less than two bars appear in the battery Recharge the battery. icon on the pump display indicating that the battery is too low. There must be at least two bars to begin a full calibration. No Code At conclusion of full calibration, pump Pump not at ambient conditions for at does not verify to within 5%. least 2 hours. Retry calibration after pump has been at ambient conditions for 2 hours. Pump not running for 2 minutes prior to calibration. Run pump for 2 minutes and retry calibration. Errors That Can Occur During Both Calibration Modes Error Problem Troubleshooting E42 Unstable average. There is too Try the calibration again. If problem much variation in the fl ow readings. persists, contact SKC Technical Support. E43 Serial time out. The calibrator is Check cable connection. If loose not communicating with the pump. or disconnected, connect properly. 22

26 Calibration Calibrating for Low Flow (5 to 500 ml/min) Sampling Applications Using a Constant Pressure Controller (CPC) For use with CPC and Adjustable Low Flow Tube Holders. The Constant Pressure Controller (CPC) is an accessory that allows low flow (5 to 500 ml/min) applications. In conjunction with an Adjustable Low Flow Tube Holder accessory, the CPC is used as a pressure regulator to maintain a constant 20 inches water back pressure. See Accessories on page 28. Calibrate with Adjustable Low Flow Holder, CPC, and representative sample medium inline. 1. a. For single-tube applications, set the flow rate to 1500 ml/min. b. For multiple-tube applications, the pump flow rate must be set at 15% higher than the sum of the flow rates through all tubes. Do not exceed 500 ml/min flow rate per tube for multiple-tube sampling. To set the pump flow rate, from HOLD press [ ] to run the pump and enter within 10 seconds. You are in User Interface Level One. SET and flow rate flash on the LCD. 2. The flow rate displayed is from the last sample taken. Press to increase flow and to decrease the flow to the desired setting. Press until End appears, and then press [ ] to save the change and exit the User Interface. The pump will remain running. If desired, press [ ] again to place the pump in HOLD. 3. Connect the pump inlet to the CPC outlet (the side of the CPC without a label) using a short length of Tygon tubing. 4. Connect the inlet side of the CPC (marked to sample ) to the Adjustable Low Flow Holder. 5. Label tube(s) and port(s). Insert an opened representative tube into the rubber sleeve of each port on the Adjustable Low Flow Holder. Place unopened tubes in any unused ports to seal them. 6. Loosen the brass flow adjust screw on the low flow holder. Connect the exposed end of one tube to a primary standard calibrator using another length of tubing. From HOLD, press [ ] to run the pump. 7. Turn the flow adjustment screw (needle valve) on the low flow holder until the calibrator indicates the desired flow rate. The flow rate displayed on the calibrator will change as a result of this adjustment. The flow rate on the pump LCD will remain at the previously set flow rate, showing the flow rate through the pump, not through the sample tube. 8. Repeat Steps 6 and 7 to calibrate the flow rate through each tube. Seal unused ports during calibration with unopened tubes. 9. Place the pump in HOLD by pressing [ ]. Disconnect the calibration train and replace the representative tube(s) with the tube(s) to be used for sampling. Reset the run time data to zero (see page 12). 23

27 Sampling Sampling (1000 to 3250 ml/min Constant Flow) 1. Following calibration, replace representative sampling medium with a new unexposed medium. Ensure run time data has been reset (see page 12). Protect sample pump from weather when in use outdoors. For multiple-tube sampling, seal unused holder ports with unopened tubes. 2. To begin sampling, press [ ] to run the pump. Record the start time. 3. Sample for the time specified in the method used. 4. To stop sampling, press [ ] to place the pump in HOLD. Record the stop time. 5. When sampling is complete, pump data is retained in memory for recovery. Data can be viewed on the LCD by using the button to scroll through it or on a PC using DataTrac 2000 Software. When using impingers, place an in-line trap between the pump and the impinger to protect the pump from harmful liquids or vapors. Failure to use the impinger trap voids the pump warranty. If a delayed start or DataTrac 2000 schedule has been programmed into the pump, it may remain in pump memory. PROG will display in the upper left corner of the pump display. To delete this program, see page 14 or 15. To ensure sample integrity, ensure tubing seals tightly onto the pump inlet filter cover. Use care when removing tubing to prevent cracking or breakage of the inlet filter cover. Low Flow Sampling (5 to 500 ml/min Constant Pressure) Low flow sampling requires a Constant Pressure Controller (CPC) and adjustable flow tube holder available as accessories or in the Low Flow Adapter Kit, Cat. No When sampling with the CPC accessory and multiple tubes, the volume displayed on the pump is no longer representative of the volume of flow through the tubes due to the air bypass function of the CPC. 1. Following calibration (see page 23), replace the representative tube(s) with a new unexposed tube(s). Protect sample pump from weather when in use outdoors. 2. Press [ ] to RUN the pump. Sample for the time specified in the method used. 3. To stop sampling, press [ ] to place the pump in HOLD. 24

28 Sampling Long-duration Color Detector Tubes require a special tube cover that accommodates an in-line trap tube. The trap tube protects the pump from caustic fumes that are often released from detector tubes. Closely read all precautions when using these tubes. Failure to use the necessary traps will damage the pump and void the warranty. To ensure sample integrity, tubing fits tightly onto the pump inlet filter cover. Use care when removing tubing to prevent cracking or breakage of the inlet filter cover. Use of any device other than the approved battery pack to power the pump voids the UL Listing for intrinsic safety. Flow Fault If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault mode. During flow fault, the pump HOLDs, the fault icon appears on the display during the length of the fault, and the accumulated run time display is frozen and retained. As part of the flow fault feature, the pump attempts to restart sampling after five minutes in flow fault and continues to attempt a restart every five minutes thereafter until the restricted flow is corrected or the pump has attempted a maximum of 10 restarts. The maximum number of restart attempts may be changed using DataTrac 2000 Software. 25

29 Maintenance Replacing the Inlet Port Housing and Filter 1. Remove the three screws that secure the inlet port housing to the top of the pump. 2. Remove the inlet port housing and gasket. 3. Remove the O-ring. 4. Remove and discard the filter. 5. Insert a new filter (Replacement Cat. No. P40011). 6. Insert O-ring*. Replace the gasket. 7. Align the inlet port housing with the three screw holes and the LED. 8. Insert the three screws and tighten in an alternating fashion. Do not overtighten screws. Overtightening can crack the inlet port. * Replace with new O-ring only as needed. 26

30 Maintenance Service Policy To return products to SKC for servicing: 1. Call ( for international customers) to obtain a Return Materials Authorization (RMA) number and Product Decontamination Form. 2. Carefully package the product. Mark the RMA number on any correspondence relating to the return and on the outside of the package. 3. Ship to SKC, freight prepaid, to the following address: SKC Inc. National Service Center 863 Valley View Road Eighty Four, PA Package product carefully to prevent damage during transit. Include a contact name, phone number, shipping address, RMA number, and a brief description of the problem. For nonwarranty repairs, a purchase order number and billing address are also required. The Service Department will contact nonwarranty customers with an estimate before proceeding with repairs. SKC Inc. will accept for repair any SKC product that is not contaminated with hazardous materials. Products determined to be contaminated will be returned unserviced. Intrinsic safety and other approvals are void if SKC pumps are not repaired by SKC or authorized SKC repair centers. Use only SKC-approved parts to ensure reliable performance and to maintain the UL Listing for intrinsic safety and the SKC warranty. 27

31 Accessories Description Cat. No. Defender Primary Standard Calibrator, 50 to 5000 ml/min, includes battery, charger ( V), cable, and software M CalChek Communication Cable, required for CalChek feature Chargers PowerFlex Charging System for SKC Personal Pumps 5-station, V Single, 120 V Single, V B PowerFlex Pump Cable for AirChek Battery Eliminator, for continuous run using line power, use voids the UL Listing for intrinsic safety 115 V V B Protective Pouches Black Red, for easy observation A Black, noise reducing C DataTrac 2000 Software Package Includes software, adapter, and serial cable, requires Windows 98 or higher and serial port or appropriate adapter compatible with PC and operating system Low Flow Adapter Kit (5 to 500 ml/min) Includes Constant Pressure Controller (CPC), Adjustable Low Flow Tube Holder, and Type A Protective Cover Constant Pressure Controller (CPC) for sampling in the 5 to 500 ml/min flow range. Use with Adjustable Low Flow Holder (below). Available in Low Flow Adapter Kit above CPC Adjustable Low Flow Tube Holders for Constant Pressure (Low Flow 5 to 500 ml/min) Applications (requires separate tube cover listed below) Single, available in Low Flow Adapter Kit above Dual Tri Quad Sample Tube Protective Covers (for adjustable flow tube holders listed above) Type A (tubes 6-mm OD x 70-mm L) A Type B (tubes 8-mm OD x 110-mm L) B Type C (tubes 10-mm OD x 150-mm L) C Type T (tandem for color detector tubes up to 115-mm long and a trap tube) T 28

32 Accessories Description Cat. No. Replacement Parts Battery Pack P20136 Battery Pack (CE marked; for Cat. No Ex) P21113 Belt Clip P20139 Case P20137 Case with interface for PC board in place P20137A Charging Jack P20145 Cover, Battery Pack P20144 Filter (inlet)/o-ring (3) P20140 Filter Housing P20142 Filters, Inlet (50) P40011 Gasket Set P21273 Keypad P79361 Stack P20138 PC Board (includes top valve plate and stack inlet) P79519 PC Board Interface P79543 Cover, Port P20179 Keypad P79361 Screw/Gasket Kit P21002 Valve Assembly, Bottom P21272 Valve Assembly, Top P21322 Long-duration Detector Tube Accessories Trap Tubes 222-3D-2 Tandem Protective Tube Cover T 29

33 Accessories DataTrac 2000 Software With the optional DataTrac 2000 Software accessory, the AirChek 2000 is programmable using a PC. DataTrac 2000 simplifies chain-of-custody reporting by allowing users the option of programming a complete running sequence, delayed start, timed stop, and intermittent sampling, all at different flow rates. Time and sample volume are continuously updated in memory. There is no need to perform lengthy calculations; DataTrac does it for you. The advanced information retrieval system is specifically designed to store data and provide chain-of-custody information. Fault features allow storage of historical data in memory that can be retrieved days later as long as the battery pack is not completely discharged. Features Program a sampling operation from a PC Calibrate the AirChek 2000 flow rate to a primary standard Display the AirChek 2000 operating state including flow rate, temperature, run time, and battery status Create and save an AirChek 2000 program on a PC and upload to the pump for operation in the field. Program up to ten sampling sequences, each with different flow rates Download the AirChek 2000 run time data and history to your PC Create chain of custody information using the sample set-up feature Print a history file containing AirChek 2000 run time data Print a worker exposure profile containing run time data and the AirChek 2000 history Document date of pump calibration and validate information when using the CalChek Automatic Calibration feature (DataTrac 2000 version 3.59 or higher) DataTrac 2000 Requirements Any IBM-compatible PC with a 386 processor or higher Hard drive with a minimum of 8 MB free disk space CD drive 4 MB RAM (8 MB preferred) VGA display or better Available 9 or 25-pin serial port (i.e., a COM port not used by a mouse, modem, or other device) or appropriate adapter compatible with PC and operating system Mouse Microsoft Windows 98 or higher DataTrac 2000 Software Includes software on CD, adapter, and serial cable. (Requires Microsoft Windows 98 or higher and serial port or appropriate adapter compatible with PC and operating system)...cat. No

34 31

User Manual (applies to all AirChek 2000 models) SKC Inc. 863 Valley View Road Eighty Four, PA USA

User Manual (applies to all AirChek 2000 models) SKC Inc. 863 Valley View Road Eighty Four, PA USA User Manual (applies to all AirChek 2000 models) SKC Inc. 863 Valley View Road Eighty Four, PA 15330 USA Form #37731 Rev 0801 Table of Contents Description...1 Performance Profile...2 Introduction Pump

More information

Operating Instructions

Operating Instructions Operating Instructions (Condensed Version) For more detailed instructions see User Manual. SKC Inc. 863 Valley View Road Eighty Four, PA 15330 USA Form #37740 Rev 0611 Table of Contents Description...

More information

Operating Instructions Leland Legacy SKC Inc. 863 Valley View Road Eighty Four, PA 15330

Operating Instructions Leland Legacy SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Operating Instructions Leland Legacy SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Form 40075 Rev 1402 Leland Legacy Quick Guide Terms» Star button Scrolls through run time data and Setup options

More information

Operating Instructions. AirChek XR5000. SKC Inc. 863 Valley View Road Eighty Four, PA USA. Form Rev 1505

Operating Instructions. AirChek XR5000. SKC Inc. 863 Valley View Road Eighty Four, PA USA. Form Rev 1505 Operating Instructions AirChek XR5000 SKC Inc. 863 Valley View Road Eighty Four, PA 15330 USA Form 38047 Rev 1505 Table of Contents Description...1 Performance Profile...2 Setup...4 Charging the Battery

More information

Pump inlet (inlet fi lter underneath) Top view. Figure 1. AirChek 52 Sample Pump

Pump inlet (inlet fi lter underneath) Top view. Figure 1. AirChek 52 Sample Pump AirChek 52 Sample Pump Cat. No. 224-52 Operating Instructions 863 Valley View Road, Eighty Four, PA 15330 USA Tel: 724-941-9701 Accessory mounting screws Pump inlet (inlet fi lter underneath) Belt clip

More information

Operating Instructions Leland Legacy SKC Inc. 863 Valley View Road Eighty Four, PA 15330

Operating Instructions Leland Legacy SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Operating Instructions Leland Legacy SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Form #40075 Rev 0606 Table of Contents Description... 1 Performance Profile... 2 Pump Setup... 4 Keypad Basics...

More information

Figure 1. AirChek XR5000 Air Sample Pump

Figure 1. AirChek XR5000 Air Sample Pump AirChek XR5000 Sample Pump Cat. No. 210-5000 Operating Instructions 863 Valley View Road, Eighty Four, PA 15330 USA Tel: 724-941-9701 Inlet port with protective filter Battery charge level indicator Bright

More information

Jerome DOSIMETER POCKET PUMP OPERATOR S MANUAL

Jerome DOSIMETER POCKET PUMP OPERATOR S MANUAL Jerome DOSIMETER POCKET PUMP OPERATOR S MANUAL September 2011 Arizona Instrument LLC 3375 N Delaware Street Chandler, AZ 85225 (602) 470-1414 (800) 528-7411 http://www.azic.com e-mail: azi@azic.com - General

More information

Operating Instructions AirLite Sample Pump Cat. No SKC Inc. 863 Valley View Road Eighty Four, PA 15330

Operating Instructions AirLite Sample Pump Cat. No SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Operating Instructions AirLite Sample Pump Cat. No. 110-100 SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Form 37814 Rev 1306 Table of Contents AirLite Quick Start Guide... 1 Description... 3 Performance

More information

Universal Sample Pump

Universal Sample Pump Operating Instructions Universal Sample Pump Cat. No. 224-PCXR8 SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Form 37713 Rev 1202 Table of Contents Description... 1 Performance Profi le...2 Operation...

More information

SKC Leland Legacy Pump for PCBs

SKC Leland Legacy Pump for PCBs STANDARD OPERATING PROCEDURES SKC Leland Legacy Pump for PCBs AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION PROJECT LOWER MANHATTAN DEVELOPMENT CORPORATION 1 Liberty Plaza New

More information

Battery compartment door. Belt clip (back of pump) Front view Top view. Figure 1. AirLite Sample Pump

Battery compartment door. Belt clip (back of pump) Front view Top view. Figure 1. AirLite Sample Pump AirLite Sample Pump Cat. No. 110-100 Operating Instructions 863 Valley View Road, Eighty Four, PA 15330 USA Tel: 724-941-9701 e-mail: skctech@skcinc.com www.skcinc.com Pump inlet (inlet fi lter underneath)

More information

Low Flow Sample Pump 222 Series

Low Flow Sample Pump 222 Series Low Flow Sample Pump 222 Series Operating Instructions SKC Inc. 863 Valley View Road Eighty Four, PA 15330 USA Form #3707 Rev 0606 13 Table of Contents Description... 1 Performance Profile... 2 Operation

More information

Universal Sample Pump Catalog No. 224-PCXR4

Universal Sample Pump Catalog No. 224-PCXR4 Operating Instructions Universal Sample Pump Catalog No. 224-PCXR4 SKC Inc. 863 Valley View Road Eighty Four, PA 15330 USA Form #37712 Rev 9904 Table of Contents Description... 1 Specifications... 2 Operation...

More information

SKC Deployable Particulate Sampler (DPS) System

SKC Deployable Particulate Sampler (DPS) System Operating Instructions SKC Deployable Particulate Sampler (DPS) System SKC Inc. 863 Valley View Road Eighty Four, PA 15330 Form 38049 Rev 1808 DPS System Quick Guide Media Preparation and Installation

More information

MTX, MTX

MTX, MTX www.skcltd.com Pocket Pump Air Sampling Pump Operating Instructions This manual covers the following models: 210-1002MTX, 210-1003MTX Purchase Details and Service History Thank you for choosing an SKC

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

SmarTire TPMS Maintenance Hand Tool. Revision User Manual SmarTire TPMS Maintenance Hand Tool Revision 1.03 User Manual Page 2 Table of Contents FCC Compliance Label...4 User Interface Illustration...4 Introduction...5 Testing Tire Sensors...5 Main Menu...6 Main

More information

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

SmarTire TPMS Maintenance Hand Tool. Revision User Manual SmarTire TPMS Maintenance Hand Tool Revision 1.04 User Manual Page 2 Table of Contents FCC Compliance Label... 4 User Interface Illustration... 4 Introduction... 5 Testing Tire Sensors... 5 Main Menu...

More information

FL-100-R (109) Operations and Installation Manual

FL-100-R (109) Operations and Installation Manual Page 1 of 23 All specification subject to change 2002-2005 FL-100-R (109) Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual

More information

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER INSTRUCTION MANUAL STEERING WHEEL TORQUE/ INCLINOMETER SYSTEM MODEL KEI-234 W / INTERNAL BARCODE SCANNER REVISION DATE: 17-AUG-1999 1 GENERAL DESCRIPTION... 3 INSTALLATION... 3 SYSTEM SETUP... 4 To change

More information

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor Product manual Oil Streak Sensor INTRODUCTION Oil streak sensors are designed to detect traces of oil travelling through air tubes, down to flows as low as 5mm 3 /min. The product utilizes a master and

More information

Universal Pump Cat. Nos XR, 224-PCXR4, and 224-PCXR8

Universal Pump Cat. Nos XR, 224-PCXR4, and 224-PCXR8 Universal Pump Cat. Nos. 224-44XR, 224-PCXR4, and 224-PCXR8 Service Manual SKC Inc. 863 Valley View Road Eighty Four, PA 15330-8619 Publication #1377 Rev 0910 Table of Contents Introduction... 1 Performance

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

EPAS Desktop Pro Software User Manual

EPAS Desktop Pro Software User Manual Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1

More information

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free DMG200 Digital Micron Gauge 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Parts Diagram 2 LCD Display Item A B C Main Numeric

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM Cap Sensors

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM Cap Sensors Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM-510 510 Cap Sensors Thank you for purchasing the TST Tire Pressure Monitoring System. With minimal care, your new

More information

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy: π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature

More information

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA   COPYRIGHT 2011 UEi 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com DMG100 Digital Micron Gauge Parts Diagram 2 LCD Display Item A B C Main Numeric

More information

Power Meter with Balancing INSTRUCTION MANUAL

Power Meter with Balancing INSTRUCTION MANUAL Power Meter with Balancing INSTRUCTION MANUAL INSTRUCTIONS The PowerMatch meter is a perfect device for matching electronic components to optimize electric fl ight performance and satisfaction. An easy-to-read

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

Online Capacity Tester MK70 User and PC-Software Manual

Online Capacity Tester MK70 User and PC-Software Manual Online Capacity Tester MK70 User and PC-Software Manual User manual Online-Battery-Tester - 2 User manual Online-Battery-Tester - 3 Introduction: With this processor controlled capacity tester you can

More information

Cannondale Diagnostic Tool Manual

Cannondale Diagnostic Tool Manual Cannondale Diagnostic Tool Manual For vehicles (ATV & Motorcycles) equipped with the MC1000 Engine Management System Software CD P/N 971-5001983 Data Cable P/N 971-5001984 POTENTIAL HAZARD Running the

More information

ESCORT ELF and ESCORT LC SAMPLING PUMPS

ESCORT ELF and ESCORT LC SAMPLING PUMPS ESCORT ELF and ESCORT LC SAMPLING PUMPS 5Sampling should always be this easy. Escort ELF Sampling Pump 5 Patented electronic laminar flow control. 5 Internal secondary standard calibrates the pump continuously

More information

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Temperature sensor jack Sensor included Model Rectifier Corporation Please read this entire manual including all Safety Cautions,

More information

Buck BioAire Model B520 Instruction Manual

Buck BioAire Model B520 Instruction Manual A.P. BUCK, INC. Buck BioAire Model B520 Instruction Manual A.P. BUCK, INC. 7101 Presidents Drive Suite 110 Orlando, FL 32809 USA Tel 1-800-330-2825 407-851-8602 Fax 407-851-8910 apbuck@apbuck.com www.apbuck.com

More information

BRAKE TESTER DECELEROMETER

BRAKE TESTER DECELEROMETER OC3010_GBM_21009 BRAKE TESTER DECELEROMETER OWNER S MANUAL Version 8.++ ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch

More information

Universal MTX Range. Meetapparatuur voor professionals MTX 224-PCMTX4 224-PCMTX8. Air Sampling Pump for any Application

Universal MTX Range. Meetapparatuur voor professionals MTX 224-PCMTX4 224-PCMTX8. Air Sampling Pump for any Application Procare saferv We take intensive care Meetapparatuur voor professionals Universal Air Sampling Pump Operating Instructions Universal MTX Range Air Sampling Pump for any Application 224-44MTX 224-PCMTX4

More information

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System Fuel Management System SentryGOLD Compact for Bennett Electronic Dispenser INSTALLATION MANUAL 2901 Crescent Drive Tallahassee, FL 32301 (850) 878-4585 office (850) 656-8265 fax www.trakeng.com support@trakeng.com

More information

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability) MODEL TI-500 RF Series Digital Weight Indicator (with wireless weighing capability) User Manual Revision 1.4 July 6, 2018 Table of Contents OVERVIEW... 3 Scope of TI-500 RF Series... 3 BASIC OPERATION...

More information

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

PH2 C50219A AIR INTAKE SHUT-OFF VALVE.   T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50219A AIR INTAKE SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER T800 KENWORTH / ISX ENGINE www.powerhalt.com INSTALLATION REQUIREMENTS & RECOMMENDATIONS:

More information

User manual MTS-32. QUI-1013 Version 1.5 January

User manual MTS-32. QUI-1013 Version 1.5 January Version 1.5 January 2015 User manual MTS-32 Page 2 Contents 1. Introduction... 3 2. Principles of operation... 3 2.1 Principles of MTS-32 ventilation... 3 2.2 Principles of sorbent tube sample collection

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

Gradient Pumping for Pressure, Flow, and Concentration Modes

Gradient Pumping for Pressure, Flow, and Concentration Modes Gradient Pumping for Pressure, Flow, and Concentration Modes With Teledyne Isco Syringe Pumps Syringe Pump Technical Bulletin TB24 Overview Gradient pumping is used in applications requiring time-controlled

More information

VSS-1 VSS-5 VSS-12 VALIDATED SAMPLING SYSTEM INSTRUCTION MANUAL

VSS-1 VSS-5 VSS-12 VALIDATED SAMPLING SYSTEM INSTRUCTION MANUAL A.P. BUCK, INC. VSS-1 VSS-5 VSS-12 VALIDATED SAMPLING SYSTEM INSTRUCTI MANUAL A.P. BUCK, INC. 7101 Presidents Drive Suite 110 Orlando, FL 32809 USA Tel 1-800-330-2825 407-851-8602 Fax 407-851-8910 apbuck@apbuck.com

More information

Applied BioPhysics Inc

Applied BioPhysics Inc Applied BioPhysics Inc 185 Jordan Rd, Troy, NY 12180 info@biophysics.com ECIS p-flow Peristaltic Pump Manual, rev D. Pump Specifications Maximum flow rate with 3.18mm ID tubing 24ml/min Minimum flow rate

More information

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE CLEAN MODE Temperature Controller User s manual CURRENT CONDITIONS ROOM TEMPERATURE PROBE TEMPERATURE OUTSIDE TEMPERATURE RELATIVE HUMIDITY STATIC PRESSURE TIME / DATE SETTINGS SET POINT / CURVE MINIMUM

More information

Installation Instructions & Users Manual

Installation Instructions & Users Manual Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

Buck BioSlide Model B1020 Instruction Manual

Buck BioSlide Model B1020 Instruction Manual A.P. BUCK, INC. Buck BioSlide Model B1020 Instruction Manual 10-20LPM Constant Flow Bioaerosol Sampling Pump For Microscope Slides Page Quick Guide 3 Product Description and Features 4 A.P. BUCK, INC.

More information

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual Manual HanTron Model HT-3P Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

Installation and User Manual. with RAIN SENSOR.

Installation and User Manual. with RAIN SENSOR. with RAIN SENSOR www.solarsmartopener.com Revision..0 TABLE OF CONTENTS Features In The Box Further Items Required Basic Operation Solar Panel and Operator Installation Operator Installation Solar Panel

More information

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01 SI AT A22 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

1. INTRODUCTION AND SYSTEM DESCRIPTION GLOSSARY CONDENSED OPERATING INSTRUCTIONS... 8

1. INTRODUCTION AND SYSTEM DESCRIPTION GLOSSARY CONDENSED OPERATING INSTRUCTIONS... 8 TABLE OF CONTENTS 1. INTRODUCTION AND SYSTEM DESCRIPTION... 6 2. GLOSSARY... 7 3. CONDENSED OPERATING INSTRUCTIONS... 8 3.1 Power ON... 8 3.2 Press Clear... 8 3.3 Select the Test Mode and press ENTER...

More information

DT304. Digital Temperature Logger INSTRUCTION MANUAL

DT304. Digital Temperature Logger INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com DT304 INSTRUCTION MANUAL Digital Temperature Logger TABLE OF CONTENTS Introduction..........................................1

More information

1. INTRODUCTION AND SYSTEM DESCRIPTION GLOSSARY CONDENSED OPERATING INSTRUCTIONS... 8

1. INTRODUCTION AND SYSTEM DESCRIPTION GLOSSARY CONDENSED OPERATING INSTRUCTIONS... 8 TABLE OF CONTENTS 1. INTRODUCTION AND SYSTEM DESCRIPTION... 6 2. GLOSSARY... 7 3. CONDENSED OPERATING INSTRUCTIONS... 8 3.1 Power ON... 8 3.2 Press Clear... 8 3.3 Select the Test Mode and press ENTER...

More information

KANEAUTO 4-4 & KANE AUTO 5-4

KANEAUTO 4-4 & KANE AUTO 5-4 KANEAUTO 4-4 & KANE AUTO 5-4 Hand Held Gas Analyser Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Tel: +44 (0) 1707 375550 Fax: +44 (0) 1707 393277 E-mail: info@kane.co.uk

More information

Installation Operation Maintenance ADDENDUM

Installation Operation Maintenance ADDENDUM Installation Operation Maintenance ADDENDUM Bulletin #: PS-IOM-HYPO2-0111-A FACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03 SI AT A22 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

Service Manual. Model L500 and L600 Smart Lift. WARNING: Cancer and Reproductive Harm - Form #1-144 Rev.

Service Manual. Model L500 and L600 Smart Lift. WARNING: Cancer and Reproductive Harm -   Form #1-144 Rev. Service Manual Model L500 and L600 Smart Lift WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov. Form #1-144 Rev. 2/5/19 Table of Contents Parts Breakdown 3 Monthly Maintenance Checklist 5

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 REV F2.0 User's Manual Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 Table of Contents INTRODUCTION...4 Starting TOOLBOX Software... 5 MAIN MENU...6 System Setup... 6 Language... 7 Select

More information

TC62D Installation Instructions

TC62D Installation Instructions TC62D Installation Instructions January 2007 This TC62D has a return water low temperature limit option. Using the low limit precludes using a room sensor because both sensors plug into the same port.

More information

SP PRO KACO Managed AC Coupling

SP PRO KACO Managed AC Coupling SP PRO KACO Managed AC Coupling Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO via the AC Load

More information

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents w w w. r o c s o l i d. c o m. a u PowerSTAR PS-2024-D Maximum Power Point Tracking Solar Regulator Contents 1 Quick Start Guide... 2 2 Specifications... 3 2.1 General Operation... 3 2.2 Absolute Maximum

More information

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6. PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER C50201A - 2007½ - 2009 DODGE 6.7L CUMMINS C50202A - 2010-2012 DODGE 6.7L CUMMINS www.powerhalt.com Thank you for your purchase

More information

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Installation Instructions Issue Date April 8, 2008 A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Application IMPORTANT: The A419 Series Electronic Temperature

More information

MoistureMatch A next generation grain tester

MoistureMatch A next generation grain tester MoistureMatch A next generation grain tester A next generation moisture tester incorporating new and unique technology. Finally, a portable tester that will more accurately match and track with the commercial

More information

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL Temperature Controller TC5+2V4SA Plus USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject

More information

THE witech SOFTWARE LEVEL MUST BE AT RELEASE **15.04** OR HIGHER TO PERFORM THIS PROCEDURE.

THE witech SOFTWARE LEVEL MUST BE AT RELEASE **15.04** OR HIGHER TO PERFORM THIS PROCEDURE. 2014 RAM 3500 HD 6.7L Eng Big Horn FLASH: 6.7L DIAGNOSTIC AND SYSTEM IMPROVEMENTS TECHNICAL SERVICE BULLETIN Reference Number(s): 18-045-15, Date of Issue: May 20, 2015 CHRYSLER: 2014 Ram 2500 Pick Up

More information

OWNERS MANUAL GPS RENTAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

OWNERS MANUAL GPS RENTAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society OWNERS MANUAL GPS RENTAL All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society Thank you for purchasing the new PowaKaddy FW5s GPS Rental Cart. Please read these

More information

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

BMS16. Thanks for your purchasing the BMS16 for your vehicle. BMS16 BMS for 2S-16S LiPo & LiFe Low power consumption High accuracy 2.8 TFT LCD display Programmable Thanks for your purchasing the BMS16 for your vehicle. Read the ENTIRE instruction manual to become

More information

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

User Manual Back-UPS BX650CI-MS 230 Vac with AVR User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety

More information

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S ( UK)

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S ( UK) User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S (123199-UK) FIG. 1 1 2 3 4 5 CALI BRAT ION I NSTRUM ENTS 6 + - Switch Test RS232 7 8 11

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

Section 55 Chapter 6

Section 55 Chapter 6 Section 55 Chapter 6 REMOTE HYDRAULICS CONTROLLER Calibration and Fault Codes 6-12880NH TABLE OF CONTENTS REMOTE HYDRAULICS CONTROLLER CALIBRATION... 55-5 Requirements For Calibration... 55-5 Aux Set Main

More information

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00 SENTRY 6141 U S E R M A N U A L ISOBUS Tip Flow Monitor Software Version 1.00 Copyrights 2016 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it

More information

TMD90A Dual Input Digital Thermometer

TMD90A Dual Input Digital Thermometer TMD90A Dual Input Digital Thermometer User Manual For detailed specifications and ordering info go to www.testequipmentdepot.com TMD90A Dual Input Thermometer Contents Safety Information 2 Symbols Used

More information

QUANTUM LX CONTROL PANEL

QUANTUM LX CONTROL PANEL Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor

More information

OPERATOR TROUBLESHOOTING GUIDE

OPERATOR TROUBLESHOOTING GUIDE OPERATOR TROUBLESHOOTING GUIDE ABOUT THE TROUBLESHOOTING GUIDE This document is provided for the use of qualified operator installers. The installer should familiarize themselves with this guide Options

More information

ST315B. User Handbook STAFFOR. ST315B Temperature Programmer. See separate handbook for Installation Instructions Issue: 2.00

ST315B. User Handbook STAFFOR. ST315B Temperature Programmer. See separate handbook for Installation Instructions Issue: 2.00 STAFFOR D ST315B User Handbook ST315B Temperature Programmer See separate handbook for Installation Instructions Issue: 2.00 ST315B Copyright User Handbook 2009-2016 Stafford Instruments Ltd. Date: 08

More information

Battery Fuel Gauge Specification

Battery Fuel Gauge Specification Battery Fuel Gauge Specification Model Number: EJ-FG09 Doc No: SPE-FG-0068 Version: 01 Date: 2014-02-18 Prepared Checked Approved Sara Jess John Manufacturer reserves the right to alter or amend the approval

More information

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION 0 8100, 9100, 9600, 9610, 9615, 9640, No errors 9650, 9700, 9710, 9705, 9750, RL5000 (SDD),RL5000 (TDM), RT2000, 9800, MAKO, SuperScrip 1 9615 Unsolicited note channel 1 2 9615 Unsolicited note channel

More information

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2 Fuel Level FL1 Revision#2.0, 28/11/2014 For firmware version 1.2 FL1 - User s manual Page intentionally left blank SECTIONS MECHANICAL INSTALLATION ELECTRICAL INSTALLATION OPERATING INSTRUCTIONS INSTRUMENT

More information

Operating and Service Manual

Operating and Service Manual Part No.: MAN755_080214 Page 1 of 16 by S Instruments, Inc. Model SR755 / SR755L Wheelchair Scale Operating and Service Manual Serial Numbers: 1514+ Part No.: MAN755_080214 Page 2 of 16 TABLE OF CONTENTS

More information

B-RAD Select USER MANUAL TABLE OF CONTENTS

B-RAD Select USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

ECLIPSE Laundry Dispenser Controller

ECLIPSE Laundry Dispenser Controller ECLIPSE Laundry Dispenser Controller Reference Manual Programming and Operation Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com Please check online

More information

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H USER NOTE: This addendum serves as additional information for Pulsafeeder PULSAR and PULSAR Shadow metering pumps equipped with

More information

Warning! General Maintenance 4-11

Warning! General Maintenance 4-11 For maximum safety, the battery charger has a Pending status LED, which lights momentarily when the head is first placed on the charger. If a battery is very low, or is out of a specific temperature range,

More information

Model AS-9234 Owners Guide Upgrade Vehicle Security & Remote Start System

Model AS-9234 Owners Guide Upgrade Vehicle Security & Remote Start System Table Of Contents: Model AS-9234 Owners Guide Upgrade Vehicle Security & Remote Start System Features Options Page 2 Page 2 Arming the System - Active Page 3 Arming the System - Passive (Automatic) Page

More information

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

BMS24. Thanks for your purchasing the BMS24 for your vehicle. BMS24 for 2S-24S LiPo & LiFe Low power consumption High accuracy 2.8 TFT LCD display Programmable Thanks for your purchasing the BMS24 for your vehicle. Read the ENTIRE instruction manual to become familiar

More information

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2-10 MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS GENERAL INFORMATION INSTALLATION & OPERATION INSTRUCTIONS 1. Clean the lines upstream of valve particles larger than 1/16" diameter (welding slag, pipe scale and other contaminants). Griswold Controls

More information

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual Kelly KDHA High Voltage Series/PM Motor Controller User s Manual KDH07500A KDH07501A KDH07700A KDH07701A KDH09400A KDH09401A KDH09500A KDH09501A KDH12400A KDH12401A KDH12500A KDH12501A KDH14300A KDH14301A

More information

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A HIMOTO ZTW Brushless Electronic Speed Control for car or truck Thank you for purchasing ZTW Brushless Electronic Speed Controller(ESC). The ZTW electronic speed control (ESC) is specifically designed for

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

EBIKE DIAGNOSIS FLOWS

EBIKE DIAGNOSIS FLOWS EBIKE DIAGSIS FLOWS 1 SUMMARY Check Tool Instructions 2 Display and Controller check tool 3 Display Holder check tool 7 Motor check tool 8 Battery check tool 9 Torque Sensor check tool 12 Customized controller

More information

GRAVITY MEASUREMENT, INC.

GRAVITY MEASUREMENT, INC. COUNTING SCALE User and Service Manual Model: CCT10/CCT20 Please read this manual carefully before operation ----General Precautions ----Operating condition and other attentions ----Warranty GRAVITY MEASUREMENT,

More information

KEMKRAFT ENGINEERING, INC. MODEL KEI-434 STEERING WHEEL TORQUE TESTER

KEMKRAFT ENGINEERING, INC. MODEL KEI-434 STEERING WHEEL TORQUE TESTER INSTRUCTIONAL MANUAL STEERING WHEEL TORQUE SYSTEM MODEL KEI-434 REVISION DATE: 14-JANUARY-1998 47650 CLIPPER DR. PLYMOUTH MICHIGAN 48170 (313)414-6500 1 GENERAL DESCRIPTION The KEMKRAFT Model KEI-434 Steering

More information