Transcription

1 Date: February 01, 2013 DOCUMENT PROJECT NO SPECIFICATIONS ADDENDUM No. 8 TO THE CONTRACT DOCUMENTS Bid Opening: February 07, 2013 OCEANSIDE AREA OFFICE REPLACEMENT FACILITY CALIFORNIA HIGHWAY PATROL 435 LA TORTUGA DRIVE VISTA, SAN DIEGO COUNTY, CALIFORNIA ACKNOWLEDGE RECEIPT OF THIS ADDENDUM ON BID FORM AND REVISE THE CONTRACT DOCUMENTS AS FOLLOWS: PROJECT MANUAL 1. SECTION PROTECTION BOLLARDS A. PARAGRAPH 2.1 POSTS DELETE Paragraph 2.1 A1: and REPLACE with the following: Use 6-inch diameter steel pipe; pounds per lineal foot. Grind off burrs and sharp edges at top; galvanized 1.2 ounce per square foot minimum after fabrication; install yellow High-density polyethylene (HDPE), UV protected cover with reflective striping after installation. 2. SECTION ABOVEGROUND WASTE OIL STORAGE TANK A. PARAGRAPH 2.01 ABOVEGROUND WASTE OIL STOAGE TANK CHANGE 250 gallons TO 280 gallons ADDENDUM NO. 7.1 PMBMSTR: 7/ of

2 CHP Oceanside Area Office Replacement Facility Page 2 B. PARAGRAPH 3.03 GUARD POSTS DELETE Paragraph A and REPLACE with the following: Install permanent guard posts as required by CFC Chapter 34 and per Specification Section SECTION ABOVEGROUND FUEL STORAGE TANK(WITH GROUND-FUEL SYSTEM) A. DELETE Specification Section , Aboveground Fuel Storage Tank (With Ground Fill System) ADD Specification Section , Aboveground Fuel Storage Tank (With Ground Fill System), Addendum 8 (02/01/13) 4. SECTION FUEL MANAGEMENT SYSTEM DRAWINGS A. PARAGRAPH 1.1 SUMMARY ADD the following sentence to paragraph A: Furnish the State 100 smart cards. 1. SHEET C5.2, CIVIL WALL DETAILS DELETE Drawing C5.2, Civil Wall Details ADD Drawing C5.2, Civil Wall Details, Addendum 8 (02/01/13) 2. SHEET 1/C5.8, FUEL ISLAND AND CANOPY PLAN NOTES ADD Note 7 with the following: Paint all step elevations yellow 2 on side and top of step. ADD Note 8 with the following: Furnish and install one (1) trash/wiper combo unit as directed by the State. Provide a 25 gallon DCI black waste/windshield/paper towel unit or equal. ADDENDUM NO. 7 PMBMSTR: 7/ of

3 CHP Oceanside Area Office Replacement Facility Page 3 3. SHEET A9.11, DETAILS A. DELETE the reference to the added Sheet A9.11, Details in Addendum 7, on page 6 of 8, Item 16. B. CHANGE R-30 to R-38 on detail 6/A9.11, Details END OF ADDENDUM NO. 8 ATTACHMENTS: SPECIFICATION SECTION DRAWING C5.2 CIVIL WALL DETAILS ADDENDUM NO. 7 PMBMSTR: 7/ of

4

5 PART 1 - GENERAL 1.1 SECTION INCLUDES SECTION A. Fuel Storage Tank system shall be used to store and to pump unleaded gasoline. All components which come into contact with fuel shall be verified by soak testing. Soak test fuels shall be per Society of Automobile Engineer (SAE) Standard. B. General: Aboveground Fuel Tanks, concrete tank pad, accessories and guard posts. C. Furnish and deliver material as listed in Section Contractor furnished items. 1.2 REGULATORY REQUIREMENTS A. International Code Council (ICC): 1. Submit ICC certification prior to commencement of on-site work. Refer to Section , Submittal Procedures Article 2.09, for ICC certification requirements. 2. Petroleum Storage tanks are regulated by Federal and State laws. Individuals installing or retrofitting Aboveground Storage Tank (AGST) systems or components must meet the following, or work under the direct and personal supervision of an individual physically present at the work site who meets the following: AGST Installation/Retrofitting. 3. The installer of the Veeder Root system shall be certified by Veeder Root as a level I and to test and operate the system shall be certified as a level IV technician. B. Air Pollution Control District (APCD): 1. Obtain approval and permits from each district in which tanks are to be installed. C. California Air Resources Board (CARB): 1. Aboveground fuel storage tank, vapor recovery and all components shall be installed per CARB Executive Order (EO) G , EO VR-302B and EO VR-401B. 2. EO G (See appendix A) is for the installation of a Phase II Vapor Recovery System as required by local Air Quality Management District (AQMD). 3. Compliant with all Executive Orders governing Standing Loss Control Vapor Recovery Systems for new installations of above ground tanks. D. California Code of Regulations (CCR): 1. Title 8, Title 19, Title Title 8, Division 1, Chapter 4, Subchapter 7, General Industrial Safety Orders. 3. Title 8, Article 144; Service Stations. 4. Title 8, Article 145; Tanks. 5. Title 19, Division 1, Chapter 11.5; Gasoline Vapor Control Systems. 6. Title 24, Part 3; Electrical Code. ADDENDUM 8 (02/01/13)

6 E. Code of Federal Regulations (CFR): 1. As administered by OSHA. F. Occupational Safety and Health Administration (OSHA): 1. Steps and handrails per 29 CFR 1910 OSHA. G. Underwriters' Laboratories, Inc. (UL) 1. U.L. Listed. a. U.L. 142 Standard for Steel Aboveground Tanks for Flammable and Combustible Liquids. b. U.L Control equipment for use with Flammable Liquid Dispensing Devices. c. UL Edition with revisions through Dec., 1999 (Including Impact and Ballistic Tests), Testing Requirements for Protected Motor Vehicle Fuel Storage Tanks. Unless approved by the State, all testing to be performed on a single fully assembled tank unit, and no part of test shall be waived. H. Calif. Building Code (CBC): 2010 edition I. Calif. Fire Code (CFC): 2010 edition 1. Section , Protected Aboveground Tanks for Motor Vehicle Fuel-Dispensing Stations Outside Buildings. 2. Sections Aboveground Tanks Outside of Buildings. J. California Heath and Safety Code 1. Section , relating to AboveGround Storage Tanks. a. Aboveground Petroleum Storage Act (APSA) transfers the responsibility for the implementation, equipment, and administration of the APSA from the State Water Resources Control Board to the certified Unified Program Agencies (CUPA), effective January 1, K. National Fire Protection Association (NFPA) 1. NFPA 30 per the most current edition: Flammable and Combustible Liquids Code. 2. NFPA 30A 2008 per the most current edition: Code for Motor Fuel Dispensing Facilities and Repair Garages. L. Certified Unified Program Agency (CUPA): 1. Obtain approval and permits from local CUPA that has jurisdiction over installation of Aboveground Flammable Liquid Tanks. 1.3 PERMITS A. APCD Required Permits: 1. Permit to construct fueling system and operating permit for first year, (Obtained and paid for by Contractor). 2. Permit to operate fueling system for second year and later, (Obtained and paid for by State). ADDENDUM 8 (02/01/13)

7 B. Permit Costs: Pay all costs required to obtain permits except as noted in 1.3-A-2. Perform required tests. Post permits on-site under glass. C. Payment Procedures: Contractor shall furnish satisfactory evidence of permit payments to State prior to final acceptance of the work. 1.4 SUBMITTALS A. Submit under provisions of Sections B. Product Data: Submit name of manufacturer, brand name, and catalog number of each item. Submit complete list at one time with items arranged in numerical sequence by Section, Article and Paragraph number. Listing item "as specified" without both make and model or type designation is not acceptable. Submit catalog cuts for each item. C. Shop Drawings: 1. Submit complete shop fabrication and field installation drawings and data. Drawings shall include all critical dimensions and show locations of all fittings, accessories, and overhead piping. D. Design calculation and drawings detailing tank seismic restraints signed and sealed by a Registered Civil or Structural Engineer licensed to practice in the State of California. E. Design calculations for the tank concrete foundation signed and sealed by a Registered Civil or Structural Engineer licensed to practice in the State of California. F. Include manufacturer s current catalog, installation manual and warranty for each supplied item. G. Test Reports and Measurements: Submit the following information to the Project Engineer: 1. Tank UL Listing Numbers (as issued by Underwriters Laboratories, Southwest Research Institute, or other State approved testing organization). 2. Proof of tank manufacturer s Product Liability Insurance in the amount of $1,000,000 minimum. 3. Completed Tank Installation Checklist. Installation Checklist shall be signed by Contractor's representative certifying that tank has been installed according to tank manufacturer's written recommendations. Obtain checklist from tank manufacturer. 4. All test reports required by CUPA. 5. All products used in fuel storage vapor recovery, fuel transferring and fuel monitoring system in contact with gasoline fuel shall be CARB certified when available. 1.5 TESTING A. Testing shall be done in accordance with NFPA 30 Standards, and per FM, APCD and CUPA requirements. B. Provide all necessary commercial grade gasoline and diesel fuel, supplies, and test equipment required for testing. C. Piping System Tests: 1. All piping shall be tested before being placed in use. Testing shall be done pneumatically to 50 psig pressure for not less than 2 hours. The pressure shall be maintained while soapsuds ADDENDUM 8 (02/01/13)

8 or equivalent materials are applied to the exterior of the piping. While applying the soapsuds, the entire run of piping, including the bottom surfaces, shall be visually inspected for leaks (bubble formations). Replace defective material disclosed by pressure test and repeat test until results are satisfactory. 2. Prior to application of test pressure, remove or valve off piping components that may be damaged by tests and install a calibrated test gage in the system. D. Vapor Tightness Tests: 1. After tank erection and installation of Phase I and Phase II components test vapor recovery systems per requirements of CARB Test Procedure TP Testing shall be conducted by a third party certified testing company. E. System Performance Test: 1. After all components of the fuel system have been properly adjusted, the system shall be tested to demonstrate that it meets the performance requirements for which it was designed. 2. The tests shall demonstrate the following: a. The capability of each fuel pumps to deliver the indicated flow of fuel. b. The alarm and control panels are operational and perform as designed. c. Each fuel meter is operating accurately. d. Vent piping is clear of debris and each pressure/vacuum relief vent is operating properly. e. Vapor recovery systems perform as designed. f. Dispensing units are operational and perform as designed. g. The capability of each emergency shutoff switches to shutdown the entire fueling operation. 3. Testing shall be conducted by a third party certified testing company. F. Contractor shall bear all fuel removal costs, and fuel disposal and/or storage costs, and cost of fuel for additional tests. 1.6 TRAINING A. Provide training to the designated State personnel in the adjustments, operation and maintenance of systems installed including but not limited to: 1. Tank fuel level monitor system. 2. Tank and piping leak monitoring system. 3. APCD and CUPA regulations concerning aboveground fuel tanks. 4. Operation of fuel supply and dispensing equipment. B. Personnel Training: Training shall be given during the regular work week after the equipment or system has been accepted. Coordinate training session with the State Construction Supervisor at a time convenient to the State. C. APCD and CUPA Permit Procedures: 1. Procedures required to obtain permits to the State. 2. Provide example forms required for permits. 3. Include APCD and CUPA contact persons and telephone numbers. ADDENDUM 8 (02/01/13)

9 1.7 FUEL A. Contractor to fill up tank upon project acceptance. PART 2 PRODUCTS 2.1 ABOVEGROUND FUEL STORAGE TANK A. General: The Insulated and Protected 12,000 gallon Aboveground Tank with 2 hours Fire rating shall be furnished as a complete factory prefabricated unit. Tank, all equipment and accessories shall be gasoline and E-85 fuel compatible when approved components are available. Accessories may be installed at the factory, or at the site, according to the tank manufacturer s standard practice. In either case, the tank and all accessories shall be certified by the tank manufacturer to meet all applicable codes and regulations, including CARB approval where required. 1. Tank shall be designed in accordance with CFC Chapter 34, NFPA 30 and NFPA 30A, and shall be UL 2085 listed including vehicle impact and projectile impact B. Components: 1. Primary containment of 1/4 inch steel, capable of on-site pressure testing for verification of primary tank integrity. 2. Non-settling thermal and physical protective material. 3. Secondary containment, with the capability of physical monitoring for leaks from the primary containment, field pressure testable, (reproducing the listing production test), and containing a means to remove liquid. Secondary containment may be inside or outside of the thermal/physical protective material, as submitted, tested and certified by UL 2085 for the tank manufacturer. 4. The exterior surface of the tank assembly, including piping, shall be painted with two coats of petroleum resistant two part epoxy paint. For corrosive environments use three part corrosion resistant paint per manufacturers specifications (DEVOE: CATHA-COAT 302H primer, BAR- RUST 235 Epoxy, Devthane 379 Enamel) or provide certification from factory that tank assembly was painted per manufacturer specifications and is 75% reflective paint. 5. The entire tank assembly, including steel, primary containment surrounded by a layer of lightweight insulating concrete providing the tank with a 2-hour fire rating. The insulating concrete shall be protected by an outer steel secondary containment tank. The insulating light weight concrete must include cement, aggregate and water. Tank shall be warranted by the manufacturer for 30 years. 6. Primary containment shall be equipped with atmospheric and emergency vents. Secondary containment shall be vented and equipped with emergency vent. 7. All openings to primary and secondary containment shall be on top. 8. Tank assembly shall be equipped with seismic anchorage brackets. Contractor shall provide anchorage design and calculations prepared by a California Registered Civil or Structural Engineer. See drawings for additional information.. 9. If used for storage and dispensing of gasoline, E-85, or other liquids regulated by CARB, tank shall be tested and equipped with required fittings. 10. Contents shall be identified and tank shall be labeled as required. Tank shall carry a label from a nationally recognized independent test laboratory showing approval for UL Standard 2085 (formerly known as UFC Standard 79-7) and shall state that the fire, hose stream, ballistics and impact tests were all performed on a single fully assembled test tank. 11. Fill ports shall be provided with over-fill shut-off protection set at 90% of tank capacity, and fuel ADDENDUM 8 (02/01/13)

10 overspill containment. Containment shall have a minimum 15 gallon capacity and manual hand pump with check valve to allow fuel return back to the tank. Tanks requiring vapor recovery shall be equipped with two point delivery systems. C. Signage: Label tanks on all vertical walls with signs that read "Flammable", "No Smoking"; appropriate fuel sign "Gasoline" and as required by State Fire Marshal and NFPA 30. Provide warnings signs and all other signage as required by CFC Chapters 22 and 34. D. Tank Accessories: Contractor shall submit submittals for State approval. Contractor shall install CARB certified components as per EO VR-401B. DESCRIPTION UNLEADED GASOLINE / E-85 Nozzle, with swivel Fuel Dispensers (internal fuel filter) & Pump Hood & Hook for Nozzle Storage/Spring Rewind Retractor With Hose Retractor Base Stand Healy HE 400 ORVR with latch, or equal. Dresser Wayne G6201D/2GJK/W1 model single nozzle, with 100:1 pulser, internal filter and Front Totalizer option, or equal. See Notes 1, 2 & 6. Pump shall be submersible turbine fuel pump. 4 inch Red jacket 3/4 H.P. Pomeco 102-AST, or approved equal. Breakaway Coupling Healy 8701 VV, or approved equal. See Note 4. Support Brackets Vapor Adaptor Tank Product Discharge Line Vapor Return Line Secondary Tank Emergency Vent Interstitial Leak Detection Tube Primary Tank Emergency Vent Fabricated, uni-strut Healy Part # CX6-VV1A or approved equal. SCH 40 Steel Pipe. SCH 40 Steel Pipe. 6 inch; Morrison 244, OPW 301, or approved equal. Supplied with Tank. 6 inch; Morrison 244, OPW 301, or approved equal. Tank Vent Riser 2 inch dia, SCH 40 steel x length required to obtain 12 foot minimum from pad. Pipe Coupling Pressure/ Vacuum Vent Valve Level Gauge 3 inch Cast Steel Flanges, Bottom Flange Threaded (Use 6 inch Dia. Fill Penetration with adjustable collar for 12,000 Gallon Tank). Steel Fitting 2 inch, upward vapor discharge, Husky model 5885 or approved equal. Morrison Clock Gage Model 818, OPW, or approved equal. SCH 40 Steel Castings. 3 inch Fill Riser Pipe SCH 40 steel pipe, butt-welded, unitized construction. ADDENDUM 8 (02/01/13)

11 DESCRIPTION UNLEADED GASOLINE / E-85 3 inch Vapor Recovery Riser Pipe SCH 40 steel pipe, butt-welded, unitized construction. 3 inch Fuel Port Check Valve OPW, Morrison, or approved equal. Fill Pipe Dry Break Style Kamvalok Adaptor w/cap inside spill box Vapor Recovery Kamvalok Adapter with cap Remote Fill Spill Container With Lid. Coaxial Hose Assembly Line Leak Detector OPW 1611 and 1612 series Kamvalok adaptors, or approved equal. OPW 1711T 1711LPC, Morrison AV or approved equal. Carbon steel, 10 gage min., all welded construction with lockable lid, painted to match tank. OPW 211-RMOT remote fill spill container, 20 gallon or approved equal. Vapor recovery 5-foot Hose HE 75 B and 6-foot Hose HE 75 B by Healy or approved equal (total hose length of 12 feet). Maximum hose length shall not exceed 13 feet including breakaways. Red Jacket line leak detector, or approved equal. Pressure Vent Valve Assembly inch W.C. pressure vent valve Healy P/N HPV 1.5 Vacuum gauge on vapor return line Thermal/Protective Material Hand Pump Hose Assembly With ¾ inch check valve Spill Containment Pan Hand Pump Vacuum gauge (0 100 wc). Install on inlet side of central vacuum unit with a tee and two ball valves. See note 6. Supplied with tank. As supplied by hand pump manufacturer, or SCH 40 steel pipe. Fill-Rite Model FR 150, GasBoy, or approved equal. Overfill Prevention Valve 4 inch dia, OPW 61f STOP-200, Morrison 9095A-0300 AV or approved equal. See Note 3. Fill Drop Tube with anti-siphon feature Overfill Alarm & Acknowledgement Device Dispenser Pan 3 inch Stainless Steel Ball Valve on fill pipe Solenoid Valve 3 inch dia. aluminum cut to length as required, OPW 61FT drop tube or approved equal. Veeder Root probe compatible with gasoline and E-85 fuel, cable and overfill alarm & Acknowledgement Device, or approved equal. 9.5 inch Bravo B-8600 retrofit aboveground steel dispenser containment pan system, with Veeder Root cable & probe, or approved equal. OPW 21BV Full port two-way ball valve, Jomar T/S-SS N-4B or approved equal. OPW 821, Morrison 710 solenoid valve or approved equal. 24 inch Manway By tank manufacturer ADDENDUM 8 (02/01/13)

12 DESCRIPTION UNLEADED GASOLINE / E-85 Ladder and Platform CAL OSHA approved ladder and platform. Submit shop drawings for approval. Accessory Support Studs Vapor Recovery System Dust Cap Swivel Adaptor By tank manufacturer Healy phase II, or approved equal, for aboveground Tank. 3 inch OPW 6343 and 634BK dust caps or approved equal. OPW 61VSA rotatable swivel adaptor or approved equal. 1. CARB approved Phase I and II Vapor Recovery Systems shall be installed on gasoline and ethanol fuel tanks. Phase II Vapor Recovery System installation is dependant on the local AQMD Onboard Refueling Vapor Recovery (ORVR) exemption approval. With an ORVR exemption approval from the local AQMD, no Phase II Vapor Recovery System shall be installed. Contractor shall check with the local AQMD for specific requirements. 2. Fuel dispenser: a. Unleaded gas, 8-10 gpm must be accomplished in the field with tank 1/2 full or less. b. All dispensers shall have explosion proof UL listed motors, 115V or 220V as shown on contract drawings, AC-60Hz, universal nozzle boot and retainer, tank mounting bracket and legs as required. c. Complete with totalizer, and a lockable device to prevent unauthorized access. d. Provide appropriate signage at the dispenser including NFPA 704 placard, emergency procedures sign, prop 65 signage, dispensing operations signage, approved containers signage, fuel sign Gasoline, Flammable, warning signs and all other signage as required by CFC Chapters 22 and 34. e. Dispenser shall be weights and measures sealable (accurate for resale). 3. Overfill prevention valve. Valve shall be designed to operate on aboveground tanks, provide a positive shut-off, and be set at 90% of tank capacity. 4. Coupling separation at 200 pounds maximum pulling force; integral, flow preventing, seals or valves activated upon coupling separating, UL listed and labeled to retain UL rating after separation. 5. Submersible Fuel Pump: a. Components: 4 inch Red Jacket centrifugal type pumping unit with screen, extractable manifold and controller with built-in check valve, air eliminator, siphon nozzle, venting, siphon check valve, relief valve, leak detector, air eliminator, built-in thermal overload and safety disconnect switch. b. Motor: 3/4 horsepower continuous duty motors, UL listed and CSA listed for Class I, Group ADDENDUM 8 (02/01/13)

13 D service. 208/230 volt, single phase, 60 hertz, 3450 rpm. Bayonet-type electrical connections to provide safe explosion proof electrical disconnect. c. Pumping Unit: Installed in tank through a standard 4 inch NPT opening with extractable manifold 4 inches below access box or containment sump cover. 6. Phase II Vapor Recovery System a. Healy, or approved equal, vacuum assist system for phase II vapor recovery for aboveground gasoline storage tank system utilizing a remote dispensers system shall include jet pump, a vapor recovery monitoring system Healy 6280A, or approved equal, piping, valves, hose adaptor, condensate trap, and power and signal connection per manufacturer s recommendation and instruction, and related accessories. b. Furnish and install a 12 x12 x ½ laminated wood shelf with bracket on wall next to Veeder Root monitoring panel to house Healy 6280A panel, or approved equal. c. Phase II Vapor Recovery System installation is dependent on local AQMD Onboard Refueling Vapor Recovery (ORVR) exemption approval. With an ORVR exemption approval from the local AQMD, no Phase II Vapor Recovery System shall be installed. Contractor shall check with the local AQMD for specific requirements E. Provide all necessary piping, tubing, fittings, and brackets required to complete the installation. Any unused tank openings shall be sealed with Schedule 40 steel pipe cap. F. Tank shall be furnished with 2 copies of calibrated charts which indicate the liquid contents in gallons for each 1/8 inch of tank depth G. List of possible tank manufacturers, (UL 2085 tested and certified tanks required): SuperVault by Modern Welding, or approved equal. H. Veeder Root Monitoring 3.2 FIRE EXTINGUISHER AND BRACKETS A. Multipurpose Dry-Chemical Type In Steel Container: UL rated 4-A, 60B:C, 10-lb capacity, with monoammonium phosphate-based dry chemical in enameled-steel container, with factory wall mounting galvanized steel L shape brackets with two straps. Brackets shall have red bakedenamel color finish. B. White color finish 12 x 6 18 gage steel name plate painted red 1 high letter Fire Extinguisher shall be mounted on wall next to fire extinguisher. 3.3 STEEL PIPE A. Carbon steel pipe shall be in accordance with ASTM A 53, Type E or S, Grade B. Pipe smaller than 2-1/2 inches shall be Schedule 80. Pipe 2-1/2 inches and larger shall be Schedule 40. B. Connections for pipe or fittings smaller than 2-1/2 inches shall be forged, socket weld type, 2000 W.O.G. conforming to ASTM A 182 and ASME B Connections for pipe or fittings 2-1/2 inches and larger shall be butt weld type conforming to ASTM A 234, Grade WPB and ASME B16.9 of the same wall thickness as the adjoining pipe. Piping in inaccessible locations shall be welded. C. Threaded connections shall only be used on piping 2 inches in nominal size or smaller and only where indicated. Connections shall be in accordance with ASME B16.3, Class 150. Threaded ADDENDUM 8 (02/01/13)

14 connections shall be sealed tightly with a thread sealant or lubricant which is compatible with the fuel to be handled. D. See Article 2.01.B.4 for painting requirements 3.4 FUEL FOR TANK AND PIPING TEST A. Contractor to provide fuel for tank and piping test. 3.5 NOT USED 3.6 CONTRACTOR FURNISHED ITEMS A. Spill Kit The Contractor shall supply a complete spill kit to the project including the following items: 1. One (1) total 50 gallon wheeled container Model 50 Gallon OverPack with Wheels from Loyola Enterprises Inc ((800) )., part number A50OVER-WD or approved equal. 2. One (1) total spill kit Model Spill Kit Refill for SPKU-50-WD from Loyola Enterprises Inc., part number RSPKU-50 including: a x19 Pads b. 6 3 x 4 Socks c x18 pillow d. 2 pair Nitrile Gloves e. 10 Yellow Disposal Bags & Ties f. 1 7 Epoxy Putty Stick g. 1 6 Light Stick h. 1 Pair Safety Goggles i. 1 Emergency Response Guidebook j. Or approved equal. 3. One (1) total seal kit Model Plug & Dike Epoxy from Loyola Enterprises Inc., part number A- P-D or approved equal 4. One (1) total absorbent material Model Sphag Sorb SS-3/4 from Loyola Enterprises Inc., part number SS-3/4 or approved equal 5. One (1) total drain cover Model Drain Protector PSI 36 Urethanes from Loyola Enterprises Inc., part number PSI-36 or approved equal. A. Storm Drain Insert System as manufacturer by Safe Drain, Inc., or approved equal 1. Provide 5 units of storm drain insert system with a single butterfly valve sized to match existing catch basin outlet pipe or a 6 valve, which ever is larger. The butterfly valve shall be equipped with an offset wheel type actuator for ease of operation without removing catch basin grate. Both valve and insert body shall be constructed of 12 or 14 gauge 304 stainless steel. Storm drain insert system shall be able to provide 100% spill containment and shall be capable of removing sediment and hydrocarbons. Provide 30 units of filtration cartridges for CHP s maintenance replacement and 2 operating tools to the State Construction Inspector. PART 3 - EXECUTION ADDENDUM 8 (02/01/13)

15 3.1 ABOVEGROUND FUEL STORAGE TANK A. Install tank in accordance with manufacturer's written recommendations and all applicable codes. B. Tank shall be separated at least 15 ft from nearest public way or building (CFC Table ). C. Provide and install anti-siphon valves at the high point of all liquid suction lines that drop below top of aboveground tanks. D. Testing: Test tank, associated piping, fittings and valves, and vapor recovery system following tank manufacturer s recommendation, CARB executive orders issued to the tank manufacturer, and CARB s and State Fire Marshal s Rules and Regulations. Tank must be tested on-site after delivery from manufacture or tank must be delivered under certified vacuum pressure. E. Not all components are listed or shown on the drawings. Contractor is to provide all components necessary to complete the installation that shall be ready to accept fuel delivery and begin dispensing operations. Installation shall include all necessary electrical services and connections that shall meet the requirements of the California Electrical Code, latest edition, for flammable and combustible liquid handling systems. 3.2 VALVE INSTALLATION A. Valves shall be installed in accessible locations. Protect valves from physical damage, and install metal tag attached with metal chain indicating fuel piping systems. Drawings indicate valve types to be used. Where specific valve types are not indicated, the following requirements apply: 1. Shutoff Duty: Use gate or ball valves. 2. Throttling Duty: Use ball valves. 3.3 PIPING INSTALLATION A. Use flanges, unions, transition and special fittings, and valves with pressure ratings same as or higher than system's pressure rating in aboveground applications, unless otherwise indicated. B. Install piping free of sags and bends. Locate groups of pipes parallel to each other, spaced to permit valve servicing. Install fittings for changes in direction and branch connections. 3.4 ABOVEGROUND TANK CONCRETE PADS A. Concrete materials, placement, and testing shall comply with Section General Requirements for Grading and Paving. 3.5 GUARD POSTS A. Install permanent guard posts as shown on Drawings. Install High Density Polyethylene (HDPE) yellow guard post sleeves on all guard posts, Ideal Shield, or equal. ADDENDUM 8 (02/01/13)

16 3.6 STORM DRAIN INSERT SYSTEM AS MANUFACTURED BY SAFE DRAIN, INC., OR APPROVED EQUAL: A. Measure dimensions of new and existing catch basins following manufacture s Measuring Guide Lines before ordering materials for installation. Order complete custom materials to fit each catch basin. Insert material to catch basins and install storm drain insert system per manufacture s recommendation on all 5 catch basins. Hand deliver additional 30 filtration cartridges to State Construction Inspector for CHP s maintenance replacement and 2 operating tools. END OF SECTION ADDENDUM 8 (02/01/13)

17

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac Minimum Specifications/Questionnaire Bid Results for One (1) New Fuel Dispensing System-Larrabee Shop Winning Bid PERMIT FEES, FORMS, PLANS and NOTIFICATIONS Secure all necessary state and local permits

More information

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B Standing Loss Control Vapor Recovery System for New Installations of Aboveground Storage Tanks WHEREAS, the California Air Resources Board

More information

SECTION VEHICLE FUEL DISPENSING EQUIPMENT

SECTION VEHICLE FUEL DISPENSING EQUIPMENT SECTION 23 10 13 PART 1 GENERAL 1.01 SUMMARY A. Provide vehicle fuel storage and dispensing equipment, including but not necessarily limited to: 1. Two compartment above ground gasoline and diesel tank.

More information

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:

More information

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

PEI/RP Recommended Practices for Installation of Bulk Storage Plants PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1

More information

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment. Shoal Lake Intake Fuel Storage and Delivery System Rehabilitation Page 1 of 10 1. GENERAL 1.1 Scope.1 The following statement generally describes the scope of work covered by this Section. All tank volumes

More information

BUREAU OF STANDARDS. Effective Date: 8/19/2016 Section No. 4. Version: 1.2 Procedure No. 3

BUREAU OF STANDARDS. Effective Date: 8/19/2016 Section No. 4. Version: 1.2 Procedure No. 3 BUREAU OF STANDARDS Effective Date: 8/19/2016 Section No. 4 Version: 1.2 Procedure No. 3 TITLE: LP Gas Bulk Plant Final Inspection PURPOSE: This document details the procedures used to conduct a Final

More information

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext. UNDERGROUND STORAGE TANK SYSTEM INSTALLATION/UPGRADE SUPPLEMENT For use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire (CFC); Chapter 6.7, Health

More information

Important Information: Aboveground Gasoline Storage Tanks Upcoming Standing Loss Control & Phase I/II EVR Requirements

Important Information: Aboveground Gasoline Storage Tanks Upcoming Standing Loss Control & Phase I/II EVR Requirements Ventura County Air Pollution Control District COMPLIANCE ASSISTANCE ADVISORY Important Information: Aboveground Gasoline Storage Tanks Upcoming Standing Loss Control & Phase I/II EVR Requirements The California

More information

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 BID ADDENDUM NO. 1 PROJECT: PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 LABELLA PROJECT NO: 2160128 DATE: FEBRUARY 11, 2016 FROM: LaBella

More information

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS Adopted 2-5-75 (Amended 9-15-75, 6-1-76, 8-3-77, 9-29-87, 12-17-91, 2-2-95, 4-3-97, 09-26-02, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY

More information

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle) Exhibit 5 Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle) Definitions common to all certification and test procedures are in: D-200 Definitions for Vapor

More information

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that

More information

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations Code Requirements What follows is a detailed chart developed by Steel Tank Institute s executive vice president, Wayne Geyer, P.E. Fire codes play a prominent role in tank purchase decisions. As such,

More information

New Amendment to Executive Orders VR-203-N & VR-204-N

New Amendment to Executive Orders VR-203-N & VR-204-N February 12, 2013 003 Technical Service Bulletin New Amendment to Executive Orders VR-203-N & VR-204-N EMCO Balance Models A4005EVR Nozzle and A4119EVR Safebreak Valve Receive CARB EVR Approval for Use

More information

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2008 edition of NFPA 30A, and the 2006 International Fire Code (IFC). Please

More information

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose

More information

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-204-U. Relating to Certification of Vapor Recovery Systems

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-204-U. Relating to Certification of Vapor Recovery Systems State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-204-U Relating to Certification of Vapor Recovery Systems Balance Phase II Enhanced Vapor Recovery (EVR) System Including In-Station Diagnostics

More information

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide - Design Guides A. SITE PLANS: Provide existing condition, removal plan, and proposed installation site plans for all tanks. Plans must include the following: 1. Dimensions of tank and any structural pads.

More information

(Please type or use black ink)

(Please type or use black ink) (Please type or use black ink) PNIPUG ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT NOTICE OF PROPOSED UST NEW INSTALLATION OR UPGRADE (Use a separate form for each separate place of operation) Date of

More information

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994. VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 70 - STORAGE AND TRANSFER OF GASOLINE (Adopted 6/25/74, Revised 9/16/75, 4/13/76, 7/6/76, 3/8/77, 6/14/77, 3/27/79, 12/2/80, 7/5/83, 11/29/88, 5/4/93,

More information

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-47 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter in Cabinet 1 Automatic

More information

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. Aboveground Tank Equipment Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally a boiler manufacturer

More information

FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST

FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL On January 26, 2005, the Maryland Department of the Environment (the Department) implemented, in the Code of Maryland Regulations (COMAR) 26.10,

More information

SECTION FACILITY FUEL OIL PIPING

SECTION FACILITY FUEL OIL PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard Copyright 2008 Earthsafe Systems, Inc. This information is provided to consulting engineers and prospective customers for the purpose of specifying Earthsafe Emergency Power Fuel Systems. Reproduction

More information

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-301-B

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-301-B State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-301-B Standing Loss Control Vapor Recovery System for Existing Installations of Aboveground Storage Tanks WHEREAS, the California Air Resources

More information

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA Lorri Grainawi Steel Tank Institute PA NISTM April 25, 2013 Harrisburg, PA PEI/RP1200-12 ------------------------------------------------------ 1. Introduction 2. Definitions 3. Safety 4. Tank Secondary

More information

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION April Meneghetti, REHS Environmental Health Divison Manager County of Yolo DEPARTMENT OF COMMUNITY SERVICES Environmental Health Division 292 West Beamer St., Woodland, CA 95695 PHONE - (530) 666-8646

More information

SECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS

SECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS SECTION 23 11 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Fuel Pipe and Pipe Fittings - General 2. Steel Pipe and Fittings, Above Grade 3. Steel Pipe and Fittings, Below Grade 4. Polyethylene

More information

General information about underground storage tank (UST) fueling systems in every day language.

General information about underground storage tank (UST) fueling systems in every day language. What this document contains: General information about underground storage tank (UST) fueling systems in every day language. What you need to know about Texas Commission on Environmental Quality (TCEQ)

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for ADDENDUM #1 The Plymouth Airport Commission is committed to fulfilling the New Fuel Farm Facility project within the scope of the permit, not exceeding our funding and to satisfy the time constraint associated

More information

A. This Section includes natural gas piping, specialties, and accessories within the building.

A. This Section includes natural gas piping, specialties, and accessories within the building. SECTION 226313 NATURAL GAS PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

FUEL DISPENSING AND STORAGE EQUIPMENT FORM 1306 (See Form 1306 Requirements and Instructions) Form 1300 must accompany this application.

FUEL DISPENSING AND STORAGE EQUIPMENT FORM 1306 (See Form 1306 Requirements and Instructions) Form 1300 must accompany this application. North Coast Unified Air Quality Management District 707 L Street Eureka, CA 95501 (707) 443-3093 FUEL DISPENSING AND STORAGE EQUIPMENT FORM 1306 (See Form 1306 Requirements and Instructions) Form 1300

More information

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations The purpose of this document is to coalesce the various

More information

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks.

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks. Rule 215 Phase II Vapor Recovery System Requirements Part 1.0 General 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks. 1.2 Applicability

More information

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-37 120V AC - 20 GPM Metered Tank-top Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter 1" Automatic Nozzle, Swivel

More information

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT DRAFT STAFF REPORT Draft Amendments to Rule 4621 (Gasoline Transfer into Stationary Storage Containers, Delivery Vessels, and Bulk Plants) and Rule 4622 (Gasoline Transfer into Motor Vehicle Fuel Tanks)

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS SECTION 22 11 23.13 (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Packaged Domestic Water Booster Pumps B. Related Sections: 1.02 REFERENCES 1. Section

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

PROJ. NO SECTION HYDRONIC PUMPS

PROJ. NO SECTION HYDRONIC PUMPS SECTION 23 21 23 HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Farm & Residential Tanks Angle skids

Farm & Residential Tanks Angle skids Farm & Residential Tanks Angle skids Multi-purpose, convenient, and economical fuel storage Each tank tested to ensure quality Engineered for strength and dependability Made with U.S. steel Tank listed

More information

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks. RULE 4622 GASOLINE TRANSFER INTO MOTOR VEHICLE FUEL TANKS (Adopted May 21, 1992; Amended November 18, 1992; Amended December 17, 1992; Amended February 17, 1994; Amended June 18, 1998; Amended September

More information

Fire & Rescue District

Fire & Rescue District Michael G. Irvan Commissioner/ Administrative Chief Shelley Young Sr. Administrative Assistant Margaret Dimmick Commissioner Jeff Ramey Commissioner Fire & Rescue District FLAMMABLE LIQUID TANK INSTALL

More information

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES Page 226113-1 SECTION 226113 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR Environmental Health - UST Program CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR As part of our inter-local contract with the Nevada Division of Environmental

More information

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. SECTION 221513 - COMPRESSED-AIR PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. 1.2

More information

40 CFR 63, Subpart CCCCCC

40 CFR 63, Subpart CCCCCC 0 CFR 3, Subpart CCCCCC The Unmatched Solution to Meeting U.S. EPA National Emissions Standards for New National Emission Standards have gone into effect for Hazardous Air Pollutants at Gasoline-Dispensing

More information

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com

More information

PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee

PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee September 2018 PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES 1.0

More information

A. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date.

A. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date. SECTION 22 50 00 FUEL OIL PIPING SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00,

More information

TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08)

TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08) RULE 61.4.1 TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08) (a) APPLICABILITY Except as otherwise provided in Section (b), this

More information

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part. TITLE 41: FIRE PROTECTION CHAPTER I: OFFICE OF THE STATE FIRE MARSHAL PART 180 STORAGE, TRANSPORTATION, SALE AND USE OF GASOLINE AND VOLATILE OILS SECTION 180.20 ABOVEGROUND STORAGE DISPENSING Section

More information

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) RULE 346. LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) A. Applicability The provisions of this rule shall apply to the transfer of organic liquids into an organic liquid

More information

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12 Ohio EPA Division of Air Pollution Control Engineering Guide #12 The purpose of this Engineering Guide (EG) is to address some questions regarding BAT and the inspection and witnessing of tests for gasoline

More information

Fuel Storage Dec 2016

Fuel Storage Dec 2016 Fuel Storage Dec 2016 1 Table of Contents SECTION I. ABOVEGROUND SMALL TANKS (1,100 GALLONS OR LESS)...3 Siting a new aboveground tank or tanks...3 Understanding fuel tank types....3 Where to find the

More information

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509) Notice of Construction (NOC) Approval Issued in accordance with: Chapter 70.94 RCW, SRCAA Regulation I, Article V, Chapter 173-400 WAC, and Chapter 173-491 WAC 3104 3104 E. Augusta, Spokane, WA 99207 (509)

More information

1. All aircraft fueling equipment shall have a Filter/Separator or a Full-Flow Fuel Monitor.

1. All aircraft fueling equipment shall have a Filter/Separator or a Full-Flow Fuel Monitor. No. 401 STANDARD SAFETY PROCEDURES STANDARD EQUIPMENT LIST FOR FUELING VEHICLES OBJECTIVE: To ensure the safety of property and personnel, the following minimum operational/equipment list, for each fueling

More information

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS INSTALLATION INSTRUCTIONS UNIVERSAL VALVE COMPANY, INC. 478 SCHILLER ST. ELIZABETH, NJ 07206 Rev A

More information

MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES

MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES SECTION 2301 GENERAL 2301.1 Scope. Automotive motor fuel-dispensing facilities, marine motor fuel-dispensing facilities, fleet vehicle motor

More information

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017 Changes to Chapter 62-761, Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017 Rule Organization The rule sections are reorganized a bit with separate sections now for:

More information

SECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)

SECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS) SECTION 02554 - FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS) 1.1 SUMMARY A. Storage tanks, fuel oil, tank accessories, piping, valves, and specialties for fuel-oil distribution inside and

More information

ANNUAL UST SYSTEM INSPECTION CHECKLIST

ANNUAL UST SYSTEM INSPECTION CHECKLIST APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date

More information

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST UNDERGROUND STORAGE TANK INSPECTION CHECKLIST Facility Name: Inspector will mail copy of this inspection report to the tank owner at: General Requirements A. Site Administration 1. Submit/revise Facility

More information

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves. Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

B2. Fueling Operations

B2. Fueling Operations B2. Fueling Operations Commercial / Industrial / Institutional & Municipal Pollution Prevention Goal: Prevent or reduce the risk of discharge of pollutants to stormwater from vehicle and equipment fueling

More information

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS SECTION 33 12 19 FIRE HYDRANTS WITH HYDRANT LOCKS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33

More information

UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL NO. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS

UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL NO. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS December 4, 2015 To: Unified Program Agencies and Other Interested Parties UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS On October 2, 2015,

More information

FREE STANDING WORK STATION JIB CRANE

FREE STANDING WORK STATION JIB CRANE SECTION 14661 FREE STANDING WORK STATION JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and

More information

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses

More information

Executive Order G F

Executive Order G F State of California AIR RESOURCES BOARD Executive Order G-70-116-F Certification of ConVault, Inc. Aboveground Filling/Dispensing Vapor Recovery System WHEREAS, the Air Resources Board (the "Board") has

More information

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of

More information

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information Papillion/La Vista Fire Marshal s Office Fuels Division FLST Section 146 rth Adams Street Papillion, NE 68046 (402) 829-1398 Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems. SECTION 210500 - COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, valves, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS A. Section 099000

More information

PEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems

PEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems PEI/RP900-08 Recommended Practices for the Inspection and Maintenance of UST Systems Recommended Practices for the Inspection and Maintenance of UST Systems CONTENTS Foreword...iii SECTIONS 1. Introduction

More information

Request For Bids. Sewer Cleaning Truck

Request For Bids. Sewer Cleaning Truck Release: Thursday 22 September 2006 Closes: Friday 6 October 2006 CITY OF BISHOP 377 West Line Street - Bishop, California 93514 Post Office Box 1236 - Bishop, California 93515 760-873-8458 publicworks@ca-bishop.us

More information

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63 SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63 The attached SPCC Plan contains introductory information, a description of facilities and practices employed to prevent

More information

Dispenser Containment Manual. Product Manual * Publication Number: DCM-0001 * Issue Date: 05/27/09 Supercedes: 11/01/07

Dispenser Containment Manual. Product Manual * Publication Number: DCM-0001 * Issue Date: 05/27/09 Supercedes: 11/01/07 Dispenser Containment Manual Product Manual * Publication Number: DCM-0001 * Issue Date: 05/27/09 Supercedes: 11/01/07 INDEX 1.0 Introduction 1.1 General Information 1.2 Independent Testing 1.3 Liquid

More information

Vehicle and Equipment Fueling

Vehicle and Equipment Fueling Vehicle and Equipment Fueling SC-20 Objectives Cover Contain Educate Reduce/Minimize Description Spills and leaks that occur during vehicle and equipment fueling can contribute hydrocarbons, oil and grease,

More information

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks. RULE 4622 GASOLINE TRANSFER INTO MOTOR VEHICLE FUEL TANKS (Adopted May 21, 1992; Amended November 18, 1992; Amended December 17, 1992; Amended February 17, 1994; Amended June 18, 1998; Amended September

More information

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015) Colorado Department of Labor and Employment Division of Oil and Public Safety Compliance Section 633 17 th Street, Suite 500 Denver, CO 80202-3610 Phone: 303-318-8525 Fax: 303-318-8518 Email: cdle_oil_inspection@state.co.us

More information

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES INTO-PLANE AUDIT CHECKLIST Audit Date: Allocation #: Station Code: City: Vendor Name: Address: Primary Contact: Title: Phone: Fax: E-mail: Auditor: Acceptable: Conditionally Acceptable Not Acceptable Register:

More information

Installation Manual ECS Membrane Processor: PMC and ISD

Installation Manual ECS Membrane Processor: PMC and ISD Installation Manual ECS Membrane Processor: PMC and ISD Part: VST ECS-CS3-310 Three Phase VST-ECS-CS3-110 Single Phase Executive Orders: VR-203-P VR-204-P Version: 4.5 Vapor Systems Technologies, Inc.

More information

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer. Exhibit 2 System Specifications

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer. Exhibit 2 System Specifications Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer Exhibit 2 System Specifications This exhibit contains the installation, maintenance and compliance standards and specifications

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit FINAL UNDERGROUND STORAGE TANK RULE CHANGES Heather Peters UST Compliance and Technology Unit Regulation Changes Federal Rule Based Changes Federal Regulations finalized in July 2015 Federal Rules effective

More information

New UST Installation Inspection Checklist

New UST Installation Inspection Checklist Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection

More information

RELIANCE G6200 MECHANICAL FLEET DISPENSER

RELIANCE G6200 MECHANICAL FLEET DISPENSER RELIANCE G6200 MECHANICAL FLEET DISPENSER Wayne Reliance G6200 Series Mechanical Fleet Dispensers Fueling capabilities you can depend on down the road Keeping your fleet on the move depends on reliable,

More information

City of Storm Lake Fire Department Heavy Rescue Specifications

City of Storm Lake Fire Department Heavy Rescue Specifications INTENT OF SPECIFICATIONS City of Storm Lake Fire Department Heavy Rescue Specifications It shall be the intent of these specifications to provide a complete apparatus equipped as hereinafter specified.

More information

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series Defender Series Overfill Prevention Valve Automatic Shutoff for USTs Installation, Operation and Maintenance 708-590 Series For use in 4" gravity-fill applications only 25-370 Gallons per Minute flow Compatible

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Catalog and Order Form

Catalog and Order Form PLACARDS CARDS, DECALS & MERCHANDISE Catalog and Order Form Let PPA Supply Your Needs This replaces all previous decal order forms. All prices subject to change without notice. 911B South Eisenhower Boulevard

More information

Underground Storage Tank. City of Burbank UST Owners & Operators

Underground Storage Tank. City of Burbank UST Owners & Operators Underground Storage Tank City of Burbank UST Owners & Operators Created by: Kern County Environmental Health CUPA, Edited by: Burbank Fire Department for the Burbank Fire Department s use Burbank Fire

More information

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3 SECTION VIII (Sub-section 430) Wastewater Valves and Appurtenances Article Page 1. General 430-1 thru 430-2 2. Gate Valves 430-2 thru 430-3 3. Plug Valves 430-3 thru 430-4 4. Check Valves 430-4 5. Tapping

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 2123 - PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information