1 INSTALLATION AND OPERATING INSTRUCTIONS CS Series Pressed Stainless Steel Centrifugal Pump Please pass these instructions on to the operator of this equipment.

2

3 Introduction Davey CS centrifugal pumps are made of 304 grade stainless steel using stamping and welding technologies which mean the pumps are compact, lightweight and efficient. Suction Piping This pump is suitable for pumping clean, clear water with a temperature between -15 C to +80 C. The maximum working pressure for this pump is 1,000kPa. Specifications Model designation (example) :- CS /4.0/3 Three phase motor Motor power (kw) Nominal dia. of impeller (mm) Diameter of outlet (mm) Diameter of inlet (mm) Series code of pump Inspection of Pump Always check on receipt of delivery you have received the correct pump unit. To identify, see above specifications and label below. Check correct motor kw & speed on motor nameplate (attached to motor) prior to installation. Delivery Upon receipt the unit should be thoroughly inspected for any damage sustained during transit. Any equipment damage or shortfall should be immediately advised to your nearest Davey office or Davey customer service centre. Storage If the unit is not to be installed immediately, it should be stored in a clean, dry and preferably warm environment. Shafts of stored motors should be rotated occasionally. Specific vibration during storage may lead to brinelling of the bearings, therefore motors that are subject to extended storage where vibration exists, should be fitted with bearing locks. All fittings & suction piping should be free of air leaks. When a suction lift or long suction lengths are unavoidable, consideration should be given to over sizing the suction line to reduce suction losses. On suction lifts a foot valve will be required, sized equal to the suction line size. For applications on creek beds or dams, please install a foot valve and strainer, well submerged below the surface, to reduce whirlpools and air inclusion. Air inclusion can result in cavitation reducing the pump performance and eventually destroying the pump or its components. If bends are required, long radius bends should be used. To help ensure a less turbulent entry into the pump, a straight length of pipe should be installed between any bends and the pump inlet. This straight length should be at least 2.5 times the pump inlet diameter in length. Pipework supports should be installed to both inlet and outlet pipes to ensure that they are supported independently of the pump flanges. Discharge Piping Installation Location The pump should be installed as close to the water source as possible to reduce the length of the suction pipe. You should always check the pump s maximum permissible suction lift from its performance curve. The pump should be installed in a place where it is well ventilated where the ambient temperature doesn t exceed +50 C. Foundations The pump unit should be mounted on a foundation that is substantial enough to withstand the weight of the unit and large enough to accommodate all mounting feet so they can be securely fixed to avoid movement. Discharge piping must be selected of a size that would equal the discharge of the pump. For long discharge lengths, consideration should be given to using larger diameter pipework. Larger size pipes have lower pressure losses for a given flow rate, and may help reduce the running costs for your pumping system. Talk to your nearest Davey Dealer to calculate all system losses. To avoid air pockets in discharge lines at high points, vent cocks may be required to release air blocks accumulated within the system. Air pockets may affect the performance of the pump. A throttling valve should be installed in the discharge line to ensure the pump works within the performance curve

4 Electrical Connection Ensure all electrical connections are solid and continuous. Check motor starter and overloads for correct rating and trip setting. All circuit breakers, HRC fuses or protective devices associated with the motor must be rated to suit motor running current and starting characteristics. Starting Caution: Do not attempt to run pump if it has not been filled with water (primed). Severe damage will result to shaft seal. 1) Ensure the suction line & pump casing is full of water open suction valve if fitted. 2) Check power is off & rotate the pump shaft slowly to release any trapped air within the pump casing. 3) Close the discharge valve. 4) Check the direction of rotation on the pump casing or motor cover. 5) Prior to initial start up, the following steps must be taken: Insulation resistance test. On machines up to 600 volt, the minimum value should be 1MΩ. Thermistors if fitted, should be checked for continuity with a multimeter and never mega-tested. Ensure supply voltage and frequency correspond to the motor nameplate ratings. Ensure shaft turns freely before initial start. Measure stator resistance and record in Log Book. 6) If this is correct you may now start the pump, when it reaches full speed you will see the pressure in the discharge line rise. Slowly open the discharge valve until the pump adjusts to maintain its duty point. Structural Representation Motor 2. Mech. seal 3. Back plate 4. Pump body 5. Float neck ring 6. Impeller 7. Impeller nut 8. Spring washer 9. Key WARNING: When installing, servicing or attending pump, always ensure power is switched off and lead unplugged. Electrical connections should be serviced only by qualified persons. If the electrical supply lead is damaged, it must be replaced , Drain plug 11. O-ring 12. Stub shaft 13. Coupling guard 14. Bell housing 15. Screw 16. Spring washer 17. Motor foot 1 Trouble Shooting Pump is running but failing to deliver water or desired pressure. 1) Turn the unit off. 2) Check suction line is free of debris or blockages and check that the pump has not lost its prime. If so, remove blockage & repeat Starting at step 1). 3) Check that the suction valve is open. 4) Check that the discharge valve is open. 5) Check for air leaks. These may not always be visible to the naked eye unless pressure is applied to the suction line. 6) Check that the suction line is not too long. 7) Is suction line to pump excessive? 8) Is the foot valve stuck open or undersized? 9) Is speed too slow? 10) Check motor direction rotation. 11) Check for possible clogging in impeller vanes 12) Is the discharge piping undersized for applications. Excessive Vibration 1) Turn the unit off. 2) Check the motor is rotating in correct direction. 3) Check both motor feet & pump feet are secured properly. 4) Check drive coupling is secured tightly to the motor shaft. 5) Check motor bearings are OK. 6) Impeller could be partially blocked causing imbalance. Noisy Operation 1) Turn the unit off. 2) Check motor bearings. 3) Check pump is primed. 4) Check suction line is not damaged, causing insufficient supply & resulting in cavitation. 5) Check you are not pumping solids. High Power Consumption 1) Check direction of rotation. 2) Check operating speed on the motor matches the intended performance curve speed. 3) Check that the estimated head is correct, as pump may be running down on its curve, producing high flow and drawing more power. Throttle the pump back on to its curve via discharge gate valve or reduce impeller diameter. 4) The Specific Gravity or Density of the liquid is greater than 1kg/litre affecting power draw. 5) Check impeller diameter for the correct size, to establish maximum power requirement at duty point. Lubrication Motor bearings are lubricated with lithium based rolling contact bearing grease, suitable for operation with-in the cooling air temperature range of -20 o C to +55 o C. For operation outside this temperature range, special lubricants are required. Special lubricants or additional maintenance may be required in the case of motors exposed to comparatively high degrees of pollution, high humidity, increased or changed bearing loads, or prolonged continuous operation

5 MOTOR OPERATION AND MAINTENANCE Installation All motors must be installed in such a manner as to ensure the air intake is not obstructed. Bed plates or slide rails should be firmly fixed to a solid, level foundation to ensure the motor remains rigid and vibration free. Shims or packers (if required) must be of adequate size and placed adjacent to and between base fixings. Operation Standard motors are designed for a 415 volt (±5% ) 3 phase, 50 Hertz supply. Use of standard motors on other supply systems should be verified with our office prior to installation. All units are S1 rated to AS1359 and associated standards, for operation below 1000 metres at a maximum ambient temperature of 40 C. For operation in conditions other than that above please contact Davey. Electric motor starting imposes severe thermal stress on the motor, the frequency of starting should be minimized to ensure optimum machine life. Number of Starts per hour The number of starts per hour is dependant on the inertia of the driven load and the load torque demand. A guide to generally acceptable starts per hour would be as per table. For greater number of starts per hour, please contact Davey. Starts per hour Frame 2 pole Permitted Starting Time In respect to the temperature rise of the motor, starting time (i.e. from rest to operational speed) should not exceed the time indicated in the following table. Motor must be allowed to cool prior to each start. Maximum starting time (sec) Frame Starting Method 2 pole 71 D.O.L D.O.L D.O.L D.O.L D.O.L D.O.L D.O.L star-delta 45 Maintenance To avoid damaging the mechanical seal, do not operate the pump without water in the pump casing. If the supply water is interrupted stop the pump immediately. Do not set the water flow by partially closing off the suction valve as restricting the supply water can cause cavitation and severely damage the pump s components. If the pump makes strange noises or vibrates, stop the pump and check for the cause/s. It is not advisable to start and stop the pump frequently. If the power is interrupted during operation, turn the power switch off immediately. If the pump is to remain inactive for a long period of time, wash the pump body and drain the water out of the pump casing completely. When the air temperature drops below 0 C, drain the water from the pump casing as soon as it finishes operating

6 Notes

7 Notes

8 Davey Repair or Replacement Guarantee In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within one year of the date of original purchase due to faulty materials or manufacture, Davey will at our option repair or replace it for you free of charge, subject to the conditions below. Should you experience any difficulties with your Davey product, we suggest in the first instance that you contact the Davey Dealer from which you purchased the Davey product. Alternatively you can phone our Customer Service line on in Australia, or in New Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund. Your Davey One Year Guarantee naturally does not cover normal wear or tear, replacement of product consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from misuse or negligent handling, improper use for which the product was not designed or advertised, failure to properly follow the provided installation and operating instructions, failure to carry out maintenance, corrosive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorized persons attempting repairs. Where applicable, your Davey product must only be connected to the voltage shown on the nameplate. Your Davey One Year Guarantee does not cover freight or any other costs incurred in making a claim. Please retain your receipt as proof of purchase; you MUST provide evidence of the date of original purchase when claiming under the Davey One Year Guarantee. Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under the Australian or New Zealand legislation and does not affect any rights or remedies that may be available to you under the Australian or New Zealand Consumer Legislation. In Australia, you are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Should your Davey product require repair or service after the guarantee period; contact your nearest Davey Dealer or phone the Davey Support Centre on the number listed below. For a complete list of Davey Dealers visit our website (davey.com.au) or call: AUSTRALIA Davey Support Centre 6 Lakeview Drive, Scoresby, Australia 3179 Ph: Fax: Website: davey.com.au NEW ZEALAND Davey Support Centre 7 Rockridge Avenue, Penrose, Auckland 1061 Ph: Fax: Website: daveynz.co.nz Davey Water Products Pty Ltd Member of the GUD Group ABN Davey is a registered trademark of Davey Water Products Pty Ltd. Davey Water Products Pty Ltd P/N

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS CM Series ISO2858 Heavy Duty Industrial Centrifugal Pump Please pass these instructions on to the operator of this equipment. Introduction Thank you for purchasing

More information

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch Davey Repair or Replacement Guarantee In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within two years of the date of original purchase due to faulty

More information

EAFM, EAFC & EAFN Filters Installation and Operating Instructions

EAFM, EAFC & EAFN Filters Installation and Operating Instructions EAFM, EAFC & EAFN Filters Installation and Operating Instructions Please pass these instructions on to the operator of this equipment. WARNING For proper operation, the inlet water pressure must be between

More information

Installation and Operating Instructions for

Installation and Operating Instructions for Installation and Operating Instructions for community water savings PRO To outlets Rainwater NOTE: Prior to installation remove the inlet and outlet pipe, transport plugs & associated seals from the suction

More information

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol Davey Repair or Replacement Guarantee In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within two years of the date of original purchase due to faulty

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or property damage. The installation of this

More information

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps Typhoon Installation and Operating Instructions WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious

More information

Davey Repair or Replacement Guarantee

Davey Repair or Replacement Guarantee Davey Repair or Replacement Guarantee In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within warranty periods beginning from the date of original purchase

More information

Automatic Pool Cleaner. Installation and Operating Instructions

Automatic Pool Cleaner. Installation and Operating Instructions Automatic Pool Cleaner Installation and Operating Instructions Please pass these instructions on to the operator of this equipment. E-mail: sales@davey.com.au Website: davey.com.au Automatic Pool Cleaner

More information

Sump Pump. Installation and Operating Instructions

Sump Pump. Installation and Operating Instructions Sump Pump Installation and Operating Instructions This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and

More information

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump NOTE: Prior to installation remove the red transport plugs & associated seals from the suction and/or discharge ports. WARNING:

More information

Installation and Operating Instructions for Davey HP/T & HS/T Pressure Systems with

Installation and Operating Instructions for Davey HP/T & HS/T Pressure Systems with Davey Repair or Replacement Guarantee In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within two years of the date of original purchase due to faulty

More information

Installation and Operating Instructions for Davey XP/T & XJ/T Pressure Systems with

Installation and Operating Instructions for Davey XP/T & XJ/T Pressure Systems with DAVEY WATER PRODUCTS GUARANTEE FOR AUSTRALIA & NEW ZEALAND Davey HP Pressure systems fitted with Torrium control are guaranteed for a period of two years from the date of original purchase to be free of

More information

Installation and Operating Instructions for Davey HS20-65Y2T Multistage Pressure System with

Installation and Operating Instructions for Davey HS20-65Y2T Multistage Pressure System with Davey Repair or Replacement Guarantee 1. The guarantee period commences on the date of original purchase of the equipment. Evidence of this date of original purchase must be provided when claiming repairs

More information

EcoPure. monarchseries.com.au. Cartridge Filter. INSTALLATION & OPERATING INSTRUCTIONS 50sqft 75sqft 100sqft 150sqft

EcoPure. monarchseries.com.au. Cartridge Filter. INSTALLATION & OPERATING INSTRUCTIONS 50sqft 75sqft 100sqft 150sqft EcoPure Cartridge Filter INSTALLATION & OPERATING INSTRUCTIONS 50sqft 75sqft 100sqft 150sqft IMPORTANT: PLEASE READ THIS DOCUMENT CAREFULLY. Please pass these instructions on to the operator of this equipment.

More information

HM Series Electric Pumps

HM Series Electric Pumps HM Series Electric Pumps Installation and Operating Instructions WARNING: The pump and associated pipework operate under pressure. Under no circumstances should the pump or associated pipework be disassembled

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G Installation & Operating Instructions BIANCO B range of submersible pumps

More information

Installation and Operating Instructions for Davey BT Series Pressure Systems with

Installation and Operating Instructions for Davey BT Series Pressure Systems with Davey Repair or Replacement Guarantee 1. The guarantee period commences on the date of original purchase of the equipment. Evidence of this date of original purchase must be provided when claiming repairs

More information

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD. CP series Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD. CP SERIES - Submersible utility pump The STAIRS CP series submersible utility pump is designed for dewatering and groundwater transferring

More information

OWNER S MANUAL Please read this manual before operating your power supply

OWNER S MANUAL Please read this manual before operating your power supply AC-DC POWER SUPPLY Switch Mode AC-DC Power Supply Model No. PSU-1210 PSU-1223 PSU-1230 OWNER S MANUAL Please read this manual before operating your power supply Table of Contents Precautions 2 Description

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Models: PMECO PMECO WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or property damage. The

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0806 SPECIFICATIONS Model No. HSE120* HSE200 HSE300*/ HSE360*/ HSEC400* HSE301 HSE361 Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2 50/2 50/2

More information

User s Manual D-Series Blowers and Exhausters

User s Manual D-Series Blowers and Exhausters User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2

More information

GeyserMax-Flow Series

GeyserMax-Flow Series GeyserMax-Flow Series 115V/60Hz Waterfall Pump GM-3900 1/5HP 150W / Discharge 1-1/2 GM-4700 1/3HP 250W / Discharge 2 GM-5400 1/2HP 400W / Discharge 2 GM-6200 3/4HP 750W / Discharge 2 230V/50Hz GM-3800

More information

WELDING FUME EXHAUSTERS & ARMS

WELDING FUME EXHAUSTERS & ARMS WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

Operation Manual Model: PPSSS Submersible Slurry Pump

Operation Manual Model: PPSSS Submersible Slurry Pump ABN 17 154 031 802 21 Ginger St, Paget Mackay Qld Australia 4740 PO Box 5709, Mackay Mail Centre Qld Australia 4741 Ph: +61 07 4998 5070 Fax: +61 07 4952 1944 Mobile: +61 0409 827 290 Email: admin@pricepumpsaustralia.com.au

More information

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY PRODUCT OVERVIEW The VADA series of self priming jet pumps combine the functional benefits of centrifugal pumps and the practical and qualitative benefits of self-priming pumps. The Venturi system the

More information

Davey Repair or Replacement Guarantee

Davey Repair or Replacement Guarantee Davey Repair or Replacement Guarantee 1. The guarantee period commences on the date of original purchase of the equipment. Evidence of this date of original purchase must be provided when claiming repairs

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. 24V DC-CW332 DOC531/11 Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. To obtain the best performance from your Pressurised water

More information

D-Series Blowers and Exhausters

D-Series Blowers and Exhausters Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual Centrifugal Pump SPC75 & SPC150 Self-Priming / Stainless Steel Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and

More information

PROCESS PUMPS (INDIA) PVT LTD

PROCESS PUMPS (INDIA) PVT LTD VERTICAL CANTILEVER SHAFT SUMP PUMP (PPCS)_ METALLIC INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROCESS PUMPS (INDIA) PVT LTD Plot No.86, III Phase, Peenya Industrial Area, Bangalore 560058 Phone:

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual 25IPCC-M 7/08 Edition PC Series C E N T R I F U G A L Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and workmanship

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,

More information

Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water. Bianco RainsaverMK6 Installation and Operating Instructions Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water. INSTRS6 rev

More information

Series Base mounted pump. Installation and operating instructions

Series Base mounted pump. Installation and operating instructions Series 4030 Installation and File No: 40.80 Date: june 25, 2015 Supersedes: 40.80 Date: october 10, 2009 contents General 4 Inspection 4 Installation - Series 4030 base mounted Pump 4 1.0 Location 4 2.0

More information

GBC Polar A4 & A3 Laminators. Instruction Manual

GBC Polar A4 & A3 Laminators. Instruction Manual GBC Polar A4 & A3 Laminators Instruction Manual 2 Technical specifications Maximum Pouch Width Maximum Pouch Thickness Warm Up Time (2x75mic) Speed GBC A4 POLAR 241mm 2x125mic (250 Total) 5 mins 240 mm/min

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS MF21 & 25 SERIES FILTER MF28 SERIES FILTER 28/03/2018 MF SERIES MEDIA FILTERS Dimensions With Valve Installed Model Height Width Shipping Weight MF21 MF25 MF28 98

More information

Australian Pump Industries AUSSIE QP OWNERS MANUAL. Aussie Fire Pumps, High Pressure Ultralites, Transfer & Trash Pumps. Revision: #7 (Oct 2018)

Australian Pump Industries AUSSIE QP OWNERS MANUAL. Aussie Fire Pumps, High Pressure Ultralites, Transfer & Trash Pumps. Revision: #7 (Oct 2018) Australian Pump Industries AUSSIE QP OWNERS MANUAL Aussie Fire Pumps, High Pressure Ultralites, Transfer & Trash Pumps Revision: #7 (Oct 2018) Reliable Products, Reliable People Australian Pump has developed

More information

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been

More information

OBE, OBEXU, ON BOARD Battery Chargers

OBE, OBEXU, ON BOARD Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBE, OBEXU, ON BOARD Battery Chargers INTRODUCTION: These chargers are designed for the permanent installation on battery powered vehicles

More information

Operating Manual Includes Pumps: PG-9000 Part #R809606

Operating Manual Includes Pumps: PG-9000 Part #R809606 Operating Manual Includes Pumps: PG-9000 Part #R809606 Introduction Thank you for selecting the PG Series Pumps from Lifegard Aquatics. Before using this pump please take a moment to review this manual.

More information

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru

More information

K681. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 2 x 2 x 2. x 2. Revision No: 4D 1

K681. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 2 x 2 x 2. x 2. Revision No: 4D 1 Fitting Kit Fitting Instructions for Basic Carrier x 4 x 2 x 2 x 2 x 2 Revision No: 4D 1 MAX kgs (lbs) W/P WHD Mitsubishi Mirage Space Star, 5dr Hatch 13-15 CN 75 kgs (165 lbs) 75 kgs (165 lbs) Mirage,

More information

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP Sunami Warranty

More information

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This

More information

K877. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 1 x 1 x 1. x 2 x 2 x 1 x 1. x 1 x 1. Revision No: 3C 1

K877. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 1 x 1 x 1. x 2 x 2 x 1 x 1. x 1 x 1. Revision No: 3C 1 Fitting Instructions for Basic Carrier x 1 x 1 x 1 x 1 x 2 x 2 x 1 x 1 x 1 x 1 Revision No: 3C 1 MAX kgs (lbs) W/P WHD Subaru Impreza, 4dr Sedan 12-+ NZ 75 kgs (165 lbs) 75 kgs (165 lbs) Impreza, 4dr Sedan

More information

EXTRA WIDE STEEL ROLLATOR

EXTRA WIDE STEEL ROLLATOR EXTRA WIDE STEEL ROLLATOR Product Codes: LM3882WBL Blue LM3882WBU Burgundy Extra Wide steel Rollator liquid coated painted frame. Soft touch hand brakes with locking mechanism. PVC extra wide seat. 8"

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems Installation Operation & Maintenance Manual Oil-Free (Dry) Rotary Vane Vacuum Pump Systems Part No. 9983-0000-S07 / November 2018 OIL-FREE (DRY) ROTARY VANE VACUUM PUMP SYSTEMS TABLE OF CONTENTS CUSTOMER

More information

PLATE CLAMPS INSTRUCTION MANUAL

PLATE CLAMPS INSTRUCTION MANUAL PLATE CLAMPS INSTRUCTION MANUAL Imported exclusively by Pacific Hoists Pty. Ltd. & Pacific Hoists Ltd. In support of cancer charities in Australia & New Zealand Universal Plate Clamp 1 Horizontal Plate

More information

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION FW000 009 Supersedes 07 END SUCTION CENTRIFUGAL PUMPS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your

More information

VERSION 2017 V.1.0

VERSION 2017 V.1.0 1 2 3 VERSION 2017 V.1.0 1300 278 283 BEFORE USING THIS PRODUCT, PLEASE READ THESE INSTRUCTIONS OF USE CAREFULLY AND MAKE YOURSELF FULLY FAMILIAR WITH THE SYSTEM. PLEASE KEEP THESE INSTRUCTIONS IN A SAFE

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMPS SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety

More information

K708. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 4 x 4. x 4. Revision No: 1A 1

K708. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 4 x 4. x 4. Revision No: 1A 1 Fitting Kit Fitting Instructions for Basic Carrier x 2 x 2 x 4 x 4 x 4 Revision No: 1A 1 MAX kgs (lbs) W/P WHD Skoda Octavia III, 5dr Liftback 09-12 NZ 35 kgs (77 lbs) 35 kgs (77 lbs) Octavia, 5dr Hatch

More information

Matson Programmable Voltage Sensitive Relay MA98411

Matson Programmable Voltage Sensitive Relay MA98411 Matson Programmable Voltage Sensitive Relay MA98411 Matson Programmable Voltage Sensitive Relay The MPVSR is a solid state electronic relay which is activated by sensing the voltage of the circuits it

More information

OWNER S MANUAL PRODUCT CODE: 2006T

OWNER S MANUAL PRODUCT CODE: 2006T Jul-18 Product Code: 2006T OWNER S MANUAL PRODUCT CODE: 2006T HYDRAULIC PIPE BENDER 12,000KG Model Capacity Bending Die No of Attachments 12,000kg 1/2", 3/4", 1", 1-1/4", 1-1/2", 2" 6 Made in China to

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS FG Bobbin Wound Fibreglass Sand Filters Bolero ND Cleaner INSTALLATION AND OPERATING INSTRUCTIONS www.astralpool.com.au

More information

Submersible Pond Pump with UV 800 Gallons Per Hour

Submersible Pond Pump with UV 800 Gallons Per Hour Submersible Pond Pump with UV 800 Gallons Per Hour REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PP800UV Questions, problems, missing parts? Before returning to your retailer,

More information

CS Series Pumps. Commercial Pumps APPLICATIONS. Davey CS Series pumps? Experts in water.

CS Series Pumps. Commercial Pumps APPLICATIONS. Davey CS Series pumps? Experts in water. Commercial Pumps Experts in water. APPLICATIONS Vineyards Diary washdown Chiller water pumping Hot water washing Treated water transfer Small industrial applications Why choose the Davey CS Series pumps?

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

K381W. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 2. x 4. Revision No: 4C 1

K381W. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 2. x 4. Revision No: 4C 1 Fitting Kit Fitting Instructions for Basic Carrier x 2 x 2 x 2 x 2 x 4 Revision No: 4C 1 MAX kgs (lbs) W/P WHD Skoda Octavia II, 4dr Liftback 04-09 NZ 75 kgs (165 lbs) 75 kgs (165 lbs) Octavia II, 4dr

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

GD series Submersible Grinder Pump

GD series Submersible Grinder Pump GD series Submersible Grinder Pump 60HZ STAIRS INDUSTRIAL CO., LTD. GD series-submersible Grinder Pump Model code GD - 15-30 - M A A = AUTO M = Single Phase T = Three Phase Connection dimensions Output

More information

OBAE, OBAEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBAE, OBAEXU, ON BOARD Battery Chargers INTRODUCTION: The OBAE line of chargers are designed for the permanent installation on battery powered

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material

More information

TPAK Series COOLANT PUMP

TPAK Series COOLANT PUMP TPAK Series COOLANT PUMP Instruction Manual ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New Taipei

More information

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1 Pump Installation and Service Manual W/D/V-A1 Submersible Sump Pump W-A1 D-A1 V-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product. OPERATOR S MANUAL 12 VOLT LITHIUM-ION BATTERY CHARGER 140446001 (R86049) Your charger has been engineered and manufactured to our high standards for dependability, ease of operation, and operator safety.

More information

OWNER S OPERATING MANUAL

OWNER S OPERATING MANUAL OWNER S OPERATING MANUAL MIG 100 GASLESS WELDER TABLE OF CONTENTS Page Safety instructions 3-4 MIG Welders 5 Welder Information 5 Gasless welder set up 6 Operation 6-10 Troubleshooting Guide 11-12 Spare

More information

Installation and Operating Instructions for Davey HS20-65TT2 Multistage Pressure System with

Installation and Operating Instructions for Davey HS20-65TT2 Multistage Pressure System with DAVEY WATER PRODUCTS LIMITED WARRANTY 1. The guarantee period commences on the date of original purchase of the equipment. Evidence of this date of original purchase must be provided when claiming repairs

More information

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified TPH Series MULTISTGE CENTRIFUGL PUMP Instruction Manual ISO 9001 Certified Walrus merica Inc 234867 EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. ddress: No. 83-14, Dapiantou, Sanjhih

More information

Installation and Operating Instructions for Davey BT Series Pressure Booster Systems with

Installation and Operating Instructions for Davey BT Series Pressure Booster Systems with DAVEY WATER PRODUCTS LIMITED WARRANTY 1. The guarantee period commences on the date of original purchase of the equipment. Evidence of this date of original purchase must be provided when claiming repairs

More information

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372 TPH Series MULTISTAGE CENTRIFUGAL PUMP Instruction Manual NSF/ANSI 372 ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.8314, Dapiantou,

More information

8000 / 10,000 / 12,000

8000 / 10,000 / 12,000 INSTALLATION AND SERVICE MANUAL Please fill in for future reference: MODEL: SERIAL NUMBER: DATE PURCHASED: EUROXXXXXX-SW S/N: XXXX-XXXXXX WARNING: PLEASE READ COMPLETELY BEFORE YOU INSTALL OR OPERATE YOUR

More information

HORIZONTAL SPLIT CASING PUMP

HORIZONTAL SPLIT CASING PUMP OPERATION & MAINTENANCE MANUAL HORIZONTAL SPLIT CASING A Mark of Quality CROSS SECTION DRAWING No. DESCRIPTION MATERIAL 01 1/4 BSP PLUG BRASS 02 LOWER HOUSING C. I. IS-210, FG260 03 IMPELLER C. I. / G.

More information

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C WARNING risk of electric shock.

More information

Motion Sensing Coach Light

Motion Sensing Coach Light TM Motion Sensing Coach Light Model: SH-9291AU Installation and Operating Instructions FEATURES Automatically comes on when motion is detected. Automatically turns light off. Photocell keeps the light

More information

Operations Manual. and. Seal Kit Replacement Guide

Operations Manual. and. Seal Kit Replacement Guide Operations Manual and Seal Kit Replacement Guide MANUFACTURED BY COLUSSI ENGINEERING PTY. LTD. TELEPHONE: (02) 9817 5433 FAX: (02) 9879 6753 53 College street, Gladesville, NSW 2111, Australia www.novapumps.com.au

More information

K131. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 2. x 2 x 4. Revision No: 2C 1

K131. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 2. x 2 x 4. Revision No: 2C 1 Fitting Instructions for Basic Carrier x 1 x 4 x 4 x 2 x 2 x 4 Revision No: 2C 1 MAX kgs (lbs) W/P WHD Toyota Estima, 5dr MPV 00-Apr 06 NZ 50 kgs (110 lbs) 50 kgs (110 lbs) Estima, 5dr MPV 00-Apr 06 NZ

More information

TPHK Series Immersible Pump

TPHK Series Immersible Pump TPHK Series Immersible Pump Instruction Manual ISO 9001 Certified Walrus America Inc 234867 EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih Township,

More information

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased Thank you for purchasing this quality-built Troy-Bilt pressure washer. We are pleased that you ve placed your confidence in the Troy-Bilt brand. When operated and maintained according to the instructions

More information

K682. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 8. x 4 x 2 x 2 x 4. x 4 x 4 x 4. Revision No: 1A 1

K682. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 8. x 4 x 2 x 2 x 4. x 4 x 4 x 4. Revision No: 1A 1 Fitting Instructions for Basic Carrier x 4 x 4 x 4 x 8 x 4 x 2 x 2 x 4 x 4 x 4 x 4 Revision No: 1A 1 MAX kgs (lbs) W/P WHD Holden Colorado 7, 5dr SUV 13-+ NZ 75 kgs (165 lbs) 100 kgs (220 lbs) Colorado

More information

AL-KO ESC USER MANUAL

AL-KO ESC USER MANUAL Vehicle Technology QUALITY FOR LIFE AL-KO ESC USER MANUAL OPERATING INSTRUCTIONS WARRANTY DETAIL About AL-KO ESC The new AL-KO ESC (Electronic Stability Control) is a sway and swerve stability control

More information

QSSE, QSSEX INDUSTRIAL Battery Chargers

QSSE, QSSEX INDUSTRIAL Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QSSE, QSSEX INDUSTRIAL Battery Chargers INTRODUCTION The QSE line are electronically controlled float chargers. The batteries are brought

More information

K309. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 2 x 2 x 4. x 1 x 2 x 1. Revision No: 7C 1

K309. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 2 x 2 x 4. x 1 x 2 x 1. Revision No: 7C 1 Fitting Instructions for Basic Carrier x 1 x 2 x 2 x 4 x 1 x 2 x 1 Revision No: 7C 1 MAX kgs (lbs) W/P WHD Toyota Emina Lucida, 4dr MPV 92-99 EU 75 kgs (165 lbs) 75 kgs (165 lbs) Emina Lucida, 4dr MPV

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS CA & ECA Series MEDIA Filters Bolero ND Cleaner INSTALLATION AND OPERATING INSTRUCTIONS ECA SERIES FILTER CA SERIES FILTER

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND

More information