END SUCTION CENTRIFUGAL PUMPS

Size: px
Start display at page:

Download "END SUCTION CENTRIFUGAL PUMPS"

Transcription

1 OWNERS GUIDE TO INSTALLATION AND OPERATION FW Supersedes 07 END SUCTION CENTRIFUGAL PUMPS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump. Be sure to check the following:. Be certain the motor is connected for the correct line voltage being used (check motor nameplate).. Be certain the pump is completely primed before starting. Otherwise damage may occur to the seal. Every pump is tested before leaving the factory, and its performance depends largely on the installation. GENERAL SAFETY INFORMATION. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).. Replace damaged or worn wiring cord immediately.. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals.. Protect the power cable from coming in contact with sharp objects. 5. Be careful when touching the exterior of an operating motor - it may be hot enough to be painful or cause injury.. Make certain that the power source conforms to the requirements of your equipment. 7. Always disconnect power source before performing any work on or near the motor or its connected load. If the power disconnect point is out-of-sight, lock it in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock.. Do not handle the pump with wet hands or when standing in water as fatal electrical shock could occur. Disconnect main power before handling unit for ANY REASON! 9. Unit must be securely and adequately electrically 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved. grounded. This can be accomplished by wiring the unit to a ground metal-clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means.. WARNING: Risk of electric shock. This pump has not been investigated for use in swimming pool areas.. WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. INSPECTION AND STORAGE. Immediately upon receipt of shipment, inspect and check the shipping document and report to the Transportation Company s local agent any damage or shortage. If the unit is received sometime before it can be used, it should be inspected, recrated and stored in a dry location.. Unless otherwise specifically agreed, all capacity, head and efficiency guarantees are based on factory test when handling clear, cold, fresh water at a temperature not over 5 F. LOCATION IMPORTANT: In installations where property damage might result from an inoperative or leaking pump due to power outages, discharge line blockage or any other reason, a back-up system(s) and/or warning system(s) should be used. 9

2 DIMENSIONS in INCHES Figure C000 SERIES Catalog Number Phase Phase HP Motor Frame Size Discharge NPT Suction NPT A B C D E F G J K SINGLE STAGE 500 RPM C JM C 5JM C5 5 JM C5 5 JM TWO STAGE 500 RPM C JM C 5JM C5 5 JM C5 5 JM C7 7-/ JM Dimensions shown above are approximate maximum dimensions for standard pumps equipped with open drip proof motors.. Locate pump as close to the fluid source as greater than that required by the unit. possible. CAUTION: The unit should be placed where the motor and electrical components are protected from the weather and extremes of heat, humidity and below freezing temperatures.. Mount unit in a dry location that is easily accessible for inspection and maintenance. Allow ample clearance around the unit for free air circulation. If a dry location is not available mount it on a foundation well above the wet floor. WARNING: Do not handle the pump with wet hands or when standing in water as fatal electrical shock could occur. Disconnect main power before handling unit for ANY REASON!. Pumps incorporate a discharge port on the pump casing that can be adjusted in 90 increments. If necessary adjust the discharge port to accommodate the specific application. Pump performance will not be affected by the position of the discharge port. SUCTION LIMITATIONS. Units are non self-priming. Normally after being primed the total suction lift of the pump is 5 feet.. Where liquids at or near their boiling points are being handled, the supply must be located above the suction, so that the available NPSH will be 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

3 PIPING. Do not use the pump as support to the piping. The pipe must be independently supported near the pump so that no strains will be transmitted to the unit. Failure to do so will cause premature pump failure and will void the warranty.. Suction and discharge sizes are selected for proper performance of the pumping unit and are not intended to determine the suction and discharge pipe sizes. Pipe sizes must be determined by the user based on the system requirements.. Install both a union and a gate valve (not furnished) on the suction and discharge side of the pump for service convenience. CAUTION: Do not use a globe or other restricting type of valve at the discharge. Globe valves seriously restrict the capacity of the pump.. All joints and connections should have pipe sealing compound (male threads only) applied and drawn up tightly. CAUTION: The entire system must be air and water tight for efficient operation. SUCTION PIPING. Suction piping should be short in length, as direct as possible, and never smaller in diameter than the pump suction opening.. Use galvanized piping, rigid plastic or other suitable pipe that will not collapse under suction.. The suction pipe should slope upward to the pump inlet. A horizontal suction line must have a gradual rise to the pump. Any high point in the pipe will become filled with air and thus prevent proper operation of the pump. When reducing the piping to the suction opening diameter use an eccentric reducer with the eccentric side down to avoid air pockets. Never use a straight taper reducer in a horizontal suction line, as it tends to form an air pocket in the top of the reducer and the pipe. Valves in Suction Piping. If the pump is operating under static suction lift conditions, a foot valve may be installed in the suction line to avoid the necessity of priming each time the pump is started.. When foot valves are used, or where there are other possibilities of liquid hammer, close the discharge valve before shutting down the pump.. The pump must never be throttled by the use of a valve on the suction side of the pump. Valves should be used only to isolate the pump for maintenance purposes, and should always be installed in positions to avoid air pockets. DISCHARGE PIPING. On long horizontal runs it is desirable to maintain as even a grade as possible. Avoid high spots, such as loops, which will collect air and throttle the system or lead to erratic pumping. Valves In Discharge Piping 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.. A check valve and gate valve should be installed in the discharge. The check valve, placed between the pump and the gate valve, protects the pump from excessive pressure, and prevents liquid from running back through the pump in case of power failure. The gate valve is used in priming and starting, and when shutting the pump down. Pressure Gauges. Properly sized pressure gauges can be installed in both the suction and discharge openings in the gauge taps which are provided. The gauges will enable the operator to easily observe the operation of the pump, and also determine if the pump is operating in conformance with the performance curve. If cavitation, vapor binding or other unstable operation should occur, widely fluctuating discharge pressure will be noted. ELECTRICAL CONNECTIONS GROUNDING. To reduce the risk of electric shock. The motor must be securely and adequately grounded to a grounded metal raceway system or by using a separate grounding wire connected to bare metal on the motor frame, or to the grounding screw located inside motor terminal box, or other suitable means. Refer to National Electric Code (NEC Article 50 [Grounding]) for additional information.. All wiring should be preformed by a qualified electrician and in accordance with the National Electric Code, Local Electric Codes and the Occupational Safety and Health Act (OSHA). WARNING: Failure to connect the motor frame to equipment grounding conductor by using green screw may result in serious electrical shock. WIRING CONNECTIONS. This unit is not water proof and is not intended to be used in showers, saunas, or other potentially wet locations. The motor is designed to be used in a clean dry location with access to an adequate supply of cooling air. Ambient temperature around the motor should not exceed F (0 C). For outdoor installations motor must be protected by a cover that does not block airflow to and around the motor. This unit is not weatherproof nor is it able to be submersed in water, or any other liquid.. Motor voltages will vary depending upon the motor horsepower, phase and manufacturer. Refer to the motor nameplate for voltage and electrical data. WARNING: Make certain that the power supply conforms to the electrical specifications of the motor supplies. Failure to do so may cause premature motor failure and will void the warranty.. For proper electrical connections, refer to the connection diagram located on the nameplate or inside the terminal box of the motor. Make sure connections are correct for the voltage being

4 supplied to the motor.. Whenever possible, the pump should be powered from a separate branch circuit of adequate capacity to keep voltage drop to a minimum during starting and running. For longer runs, increase wire size in accordance with the Wire Selection Guide. (See Figures & ) Increaser Gate Valve Check Valve Figure INSTALLATION DIAGRAM Suction Pipe Installed With Gradual Rise To Pump Inlet Eccentric Reducer Center Line Of Pipe Level NOTE: Wire charts are for reference only. Consult local and state codes for approved wire sizes. WARNING: Always disconnect power source before performing any work on or near the motor or its power source. Failure to do so could result in personal injury or fatal electrical shock. Distance From Motor To Fuse Box Meter, or Electrical Outlet 0 ft. 50 ft. 00 ft. 00 ft. 500 ft. 5V 0V 5V 0V 5V 0V 5V 0V 5V 0V. SINGLE PHASE Recommended Copper Wire Size HP -/ HP HP HP 5 HP () Not economical to run at 5V, use 0V. Figure Distance From Motor To Fuse Box Meter, or Electrical Outlet 0 ft. 50 ft. 00 ft. 00 ft. 500 ft. Figure 0V 0V 0V 0V 0V 0V 0V 0V 0V 0V THREE PHASE Recommended Copper Wire Size HP -/ HP HP HP 5 HP 7-/ HP MOTOR PROTECTION WARNING: Never examine, make wiring changes or touch the motor before disconnecting the main electrical supply switch.. Motors may or may not have built-in thermal overload protection depending upon the horsepower size, phase, type and motor manufacturer. Refer to the motor nameplate for overload protection information. It is recommended that a properly sized magnetic or manual starter (both with properly sized heaters) be used with all motors. Install starters following instructions of the starter manufacturer. See Figure 5 & for magnetic starter wiring diagram.. All motors (single and three phase) should be equipped with a correctly fused disconnect switch to provide protection. Consult Local or National Electrical Codes for proper fuse protection based on motor nameplate.. Undersize wiring can cause motor failure (low voltage), frequent cut-out of motor overload protector, television interference and even fire. Make certain the wiring is adequately sized (Figure & ), well insulated and connected to a separate circuit outside the building in case of fire. Magnetic Starter Wiring Diagram - Single Phase Pressure Switch V L T L M W Fused Disconnect Switch Lightning Arrestors T X T Warning: Connect motor leads momentarily for correct rotation Figure 5 Motor # Or Heavier Copper Ground Wire, Connect To ft. Ground Rod Or Well Casing 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

5 Magnetic Starter Wiring Diagram - Three Phase Fused Disconnect Switch L L L W Lightning Arrestors Pressure Switch V M X T T T IL0 T Motor # Or Heavier Copper Ground Wire, Connect To ft. Ground Rod Or Well Casing Figure OPERATION PRIOR TO STARTING. Before the pump is started initially, make the following inspections: Check Rotation - Be sure that the pump operates in the direction indicated by the arrow on the pump casing, as serious damage can result if the pump is operated with incorrect rotation. Rotation is always counterclockwise facing the pump suction. Operating the pump in reverse rotation may cause extensive damage. Check all connections to motor and starting device with wiring diagram. Check voltage, phase and frequency on motor nameplate with line circuit. ALL PUMPS WITH PHASE MOTORS MUST BE INSTALLED WITH A MAGNETIC STARTER WHICH PROVIDES -LEG PROTECTION FOR MOTOR. FAILURE TO USE CORRECT STARTER WILL VOID THE WARRANTY North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

6 PRIMING. Before starting any centrifugal pump it is absolutely necessary that both the casing and suction pipe be completely filled with liquid. This priming can be accomplished by any of the following methods.. When the liquid supply level is above the center line of the pump, it is primed by opening the suction and discharge valves. The inflowing liquid will displace the air and fill the suction line, pump casing, and discharge line up to the level of supply.. Where the pump is operating with suction lift and the suction line is equipped with a foot valve, the system is filled with liquid by filling through the discharge piping. STARTING. Follow the steps below in the order indicated to start pump: Close gate valve in discharge line. Open gate valve in suction line. Turn on power to pump motor.. When pump is operating at full speed, immediately open the discharge gate valve slowly.. If the pump does not prime properly, or loses it PROPERTIES OF WATER Temperature ºF Absolute Vapor Pressure PSI Ft. Water Specific Gravity Altitude (Feet) Barometer Inches Mercury PSIA Atmospheric Pressure (ft. water) Boiling Point ºF North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

7 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Low or no discharge. Incorrect rotation. Refer to wiring diagram. Insufficient inlet pressure or suction head (NPSH Required). Increase inlet pressure by adding more fluid to fluid source. (See Spec s for minimum NPSH Required). Total head too high. Lower discharge head. Leak in suction line. Repair or replace 5. Impeller clogged or damaged 5. Clean or replace. Wrong size piping. Make needed adjustments 7. Casing gasket leaking 7. Replace gasket. Suction or discharge line valves closed. Open 9. Mechanical seal leaking 9. Replace Loss of suction. Insufficient inlet ressure or suction head (NPSH Required). Increase inlet pressure by adding more fluid to fluid source. (See Spec s for minimum NPSH Required). Clogged strainer. Clean or replace Pump vibrates and/or. Mounting plate or foundation not rigid. Reinforce makes excessive noise enough. Foreign material in pump. Clean. Damaged impeller. Replace. Cavitation present. Check suction line for proper size and be sure valve is open. Remove excessive loops in suction line. (See Spec s for minimum NPSH Required) Pump leaks at shaft. Damaged or worn mechanical seal. Replace. Corrosion due to character of liquid. Discontinue pumping liquid and consult factory pumped Pump will not start or. Improperly wired. Refer to wiring diagram run. Blown fuse or open circuit breaker. Replace fuse or close circuit breaker. Loose or broken wiring. Tighten connections and replace broken wiring. Impeller clogged. Clean 5. Motor shorted out 5. Replace Motor problems. Various. Consult qualified electrician. Overloading motor. Too much water. Restrict outlet by closing down valve in discharge line delivery. Liquid heavier and more viscous than. Consult factory water. Seal binding. Replace 5. Rotor binding 5. Repair or replace. Voltage and frequency lower than rating. Reconnect to rated voltage and frequency 7. Defects in motor 7. Repair or replace Pinholes in the casting. Liquid dripsp around seal area but is not seal. Cavitation caused by insufficient inlet pressure or suction head (NPSH Required). Increase inlet pressure by adding a higher level of fluid to source or increasing inlet pressure. (See Spec s for minimum NPSH Required) 7 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

8 CENTRIFUGAL PUMP REPAIR PARTS C000 SERIES (For Pricing Refer To Repair Parts Price List) FORM NO. FW SUPERSEDES 07 PAGE -5A REPAIR PARTS 9 5 Qty. Item No. 0 Repair Kit Kit Includes: Part No. & Description Two Stage Seal Assembly 57 O-Ring, Cap Screw 57 O-Ring, Impeller 59 O-Ring, Impeller Gasket 5 7 Single Stage IL000 Product may not be exactly as shown. ITEM HORSEPOWER / STAGE SINGLE PHASE C C5 C C5 THREE PHASE C C5 C C5 C7 DESCRIPTION PART NUMBER Motor Phase Motor Phase Mounting Ring Seal Assembly Key / x 7/ Key / x -/ Impeller O-Ring, Impeller Retainer, Impeller Cap Screw Long O-Ring, Cap Screw Lock Washer / S.S. Gasket Intermediate Stage w/clearance Ring Clearance Ring - Large Clearance Ring - Small Impeller (Front) Retainer, Impeller O-Ring, Impeller Cap Screws -/ Long O-Ring, Cap Screw Lock Washer / S.S. Suction Flange Assembly w/clearance Ring Clearance Ring Pipe Plug / NPT Hex Hd. Cap Screws / x Hex Hd. Cap Screws / x -/ Hex Hd. Cap Screws / x -/ () Standard hardware item () Not shown () () () () () () () () 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved () (5) () () () (5) () () () (5) () ()

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS FW000 0 Supersedes 009 READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump.

More information

LAWN SPRINKLER, IRRIGATION PUMP

LAWN SPRINKLER, IRRIGATION PUMP LAWN SPRINKLER, IRRIGATION PUMP MODEL #, SP0P, SP5P, SP20P, EL0P, EL5P, EL20P SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

SHALLOW WELL JET PUMP

SHALLOW WELL JET PUMP SHALLOW WELL JET PUMP MODEL FJ05S 1/2 HP flintandwalling.com ATTACH YOUR RECEIPT HERE Serial Number Purchase Date 1 FW1642 B TABLE OF CONTENTS Product Specifications...2 Safety Information...2 Package

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

STAR STOP SHALLOW WELL JET PUMP

STAR STOP SHALLOW WELL JET PUMP SHALLOW WELL JET PUMP MODEL SJ0S / HP STAR starwatersystems.com STOP Questions, problems, missing parts? Before returning to your retailer, call our customer service department at -800-7-0, 7:0 a.m. -

More information

GARDEN HOSE UTILITY PUMP

GARDEN HOSE UTILITY PUMP GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13 GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance KP-C Series Close Coupled End Suction Centrifugal Pumps Installation, Operation and Maintenance PUMP MODEL NOMENCLATURE KP - 8 x 6 x 16 - E C - AI - BCM Pump Series Suction Pipe Size (in) Discharge Pipe

More information

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS FW0080 0511 Supersedes 0610 OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS IL0632 WARNING IMPORTANT SAFETY INSTRUCTIONS RULES FOR SAFE INSTALLATION

More information

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately) Installation Instructions and Parts Manual CPJ SERIES JET PUMPS Shallow Well Jet Pumps /3 - / HP CPJS SHALLOW WELL IL089 3/4 - -/ HP CPJS SHALLOW WELL Convertible Jet Pumps IL090 / HP CPJ CONVERTIBLE IL09

More information

Sealless Centrifugal Canned Motor Pumps

Sealless Centrifugal Canned Motor Pumps Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B MODELS 25M/B, 50M/B and 200M/B CENTRI-THRIFT CENTRIFUGAL PUMPS NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B MODELS 25M/B, 50M/B and 200M/B ½, 2, AND 7½ HP SINGLE AND THREE PHASE CENTRI-THRIFT CENTRIFUGAL PUMPS NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual 25IPCC-M 7/08 Edition PC Series C E N T R I F U G A L Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and workmanship

More information

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual FW1206 0608 Supersedes NEW Owner Information System Model Number Pump Model / Date Code Pump Serial Number (Silver

More information

2 Wire Plus Ground 3 Wire Plus Ground IL0655

2 Wire Plus Ground 3 Wire Plus Ground IL0655 4 INCH SUBMERSIBLE WELL PUMP 2 & 3 Wire 2 Wire Plus Ground 3 Wire Plus Ground Español p. 21 For installation videos and other information, scan with your smart phone. Or, visit: starwatersystems.com and

More information

barmesapumps.com IB SERIES & 3500 RPM Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps

barmesapumps.com IB SERIES & 3500 RPM Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps IB SERIES 1-15 HP @ 1750 & 3500 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a pump. Before

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNER S MANUAL 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST MEDIUM HEAD HIGH HEAD MODELS 1 HP 1-1/2 HP 2 HP 2-1/2 HP DMMG-42L DMG-41L DMMG3-42

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS Models 125M/B, 150M/B and 200M/B ENGLISH: PAGES 2-8 Installation and Service Manual NOTE! To the installer: Please make sure you provide

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual Centrifugal Pump SPC75 & SPC150 Self-Priming / Stainless Steel Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and

More information

End Suction Centrifugal

End Suction Centrifugal M o d e l s 3 U / 3 U B End Suction Centrifugal Operating Instructions, Installation & Maintenance Manual Certified to NSF/ANSI 6, ANNEX G * NSF/ANSI 6 Annex G listed models: 3U EBARA International Corporation

More information

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNER S MANUAL 60 Cycle CT Series Centrifugal Pump INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST HP MODELS 1/2 CTJ05B CTJ05B3 CTJ05 CTJ053 3/4 CTJ07B CTJ07B3 CTJ07 CTJ073 1 CTJ10B CTJ10B3 CTJ10

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting Electrical wiring and connections should be done

More information

Marlow Series Cast Iron Swimming Pool Pumps

Marlow Series Cast Iron Swimming Pool Pumps INSTRUCTION MANUAL SECTION 360A AC1683 REVISION C INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER'S USE. Marlow Series Cast Iron Swimming Pool Pumps 3B28EC 3B32EC PLEASE FILL IN DATA FROM YOUR PUMP NAMEPLATE

More information

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL IMPORTANT These instructions are intended as a guide for the Installing Contractor and as a reference for the Operator, Owner and Serviceman. RETAIN

More information

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps CD SERIES 1-3 HP @ 3450 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a

More information

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS TO OBTAIN THE BEST PERFORMANCE FROM YOUR PROMAG SR PUMP, PLEASE READ THE MANUAL CAREFULLY. Failure to

More information

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting Electrical wiring and connections should be

More information

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS 1 HP 1-1/2 HP 2 HP 2-1/2 HP DMG-41L DMMG-42L MEDIUM HEAD DMG3-41 DMMG3-42

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems Fuel Oil Transfer System THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED SYSTEM IS OF THE HIGHEST QUALITY AND DESIGN. TO OBTAIN

More information

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com JET PUMP INSTALLATION

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators PHR Axial Flow Hooded Roof Ventilators OPERATION & MAINTENANCE Revised: 08/24/15 IMPORTANT! READ BEFORE PROCEEDING! The information contained herein is, to the best of our knowledge, accurate and applicable

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 50WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

60 Series End-Mount Brake Instructions Standard Housing

60 Series End-Mount Brake Instructions Standard Housing Bulletin No. BK4655 (04/18) 60 Series End-Mount Brake Instructions Standard Housing Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and

More information

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions Wilo SP Series Submersible Utility Pumps ETT ETT24-10.25 Installation and operating instructions 1. PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can be damaged during

More information

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST BELT TYPE IMPORTANT PLEASE MAKE CERTAIN THAT THE PERSON WHO IS TO USE THIS EQUIPMENT CAREFULLY READS AND UNDERSTANDS THESE INSTRUCTIONS BEFORE STARTING

More information

SERIES PC INSTRUCTION AND OPERATION MANUAL

SERIES PC INSTRUCTION AND OPERATION MANUAL MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this

More information

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing Bulletin No. BK4775-3 (08/2016) 70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing Read carefully before attempting to assemble, install, operate or

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.

More information

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting Electrical wiring

More information

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Pump Curves...2 Pump End Assembly...3 Disassembly...3 Installation...4

More information

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73 Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI 15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual Operating Instructions & Parts Manual EN Hazardous Location Direct-Drive Exhaust Fans Models 10D996 thru 10D999, 10E001 thru 10E007, 10E009 thru 10E020, 32ZN53 and 32ZN54 474904 PLEASE READ AND SAVE THESE

More information

SS/SSH Submersible Pump. Owner s Manual

SS/SSH Submersible Pump. Owner s Manual Est. 1985 www.aquascience.net SS/SSH Submersible Pump Owner s Manual 4 SUBMERSIBLE PUMP INSTALLATION INSTRUCTIONS IMPORTANT: Read this manual carefully before installing or operating the pump. Review instructions

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing Bulletin No. BK4773-3 (08/2016) 70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing Read carefully before attempting to assemble, install, operate or maintain the product described.

More information

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:

More information

Self-Priming Centrifugal Pumps

Self-Priming Centrifugal Pumps OWNER S MANUAL Self-Priming Centrifugal Pumps 293 Wright Street, Delavan, WI 53115 D Series 1362 1094ASBN Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Low Profile J Series Power Unit with Vane Pump

Low Profile J Series Power Unit with Vane Pump Low Profile J Series Power Unit with Vane Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing Bulletin No. BK4772S-3 (6/2017) 70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing Read carefully before attempting to assemble, install, operate or maintain the product described.

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. 24V DC-CW332 DOC531/11 Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. To obtain the best performance from your Pressurised water

More information

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE INSTALLATION, SERVICE & PARTS MANUAL Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE Self-Priming Universal Pumps ISP No: PFCCE - 4/14 PF-CCE General Safety Information Before installation,

More information

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS 471 US Hwy 250 East, Ashland, Ohio 44805 PH: 419-207-9400 FX: 419-207-8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS 10/2014

More information

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation

More information

Voltmaster Centrifugal Trash Pumps

Voltmaster Centrifugal Trash Pumps Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2

More information

Centrifugal Constant Pressure Control

Centrifugal Constant Pressure Control Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding

More information

High Velocity Series Air Curtains

High Velocity Series Air Curtains INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL FOR ALL 208-230/480 VOLT 3 PHASE. MOTOR MODELS High Velocity Series Air Curtains READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR

More information

INTRODUCTION Please read this manual

INTRODUCTION Please read this manual 1 INTRODUCTION Please read this manual carefully to learn how to safely install and operate your pump. Failure to do so could result in personal injury or damage to the pump. If there are any questions

More information

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase TABLE OF CONTENTS Product Numbering System and Specifications... Safety... Receiving and Inspection... Installation... Electrical...6 Start-up...7 INTRODUCTION The compressor you have purchased is a combination

More information

AUTOMATIC SUBMERSIBLE UTILITY PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP AUTOMATIC SUBMERSIBLE UTILITY PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1043-0006 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODELS #1073-0001, 1075-0001 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1099-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Centrifugal Pump Primer 383 0893 MODEL 6D, HAN-DEE PRIMER IMPORTANT For best possible performance continuous, satisfactory operation,

More information

METERING/DOSING PUMP CLOSE-COUPLED B4015D, B4050D, B4100D, B4190D, B2400D, AND B4400D MODELS

METERING/DOSING PUMP CLOSE-COUPLED B4015D, B4050D, B4100D, B4190D, B2400D, AND B4400D MODELS Section: METERING/DOSING PUMPS Page: 1 of 5 Date: July 2009 SERVICE MANUAL METERING/DOSING PUMP CLOSE-COUPLED B4015D, B4050D, B4100D, B4190D, B2400D, AND B4400D MODELS DESIGN FEATURES Suction Housing:

More information

VSCP Vertical Suspended Column Pump Operation & Maintenance Manual

VSCP Vertical Suspended Column Pump Operation & Maintenance Manual Issue Date: January 1980 PUMP IDENTIFICATION Congratulations! You are the owner of the very best Column pump commercially available. With proper care and maintenance it will provide you with reliable service

More information

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , , POWERLINE XP I Swimming Pool Pump (Light Oak color model) 3 FT CORD UL/NEC Models 0-1295-206, 0-1296-206, 0-1297-206, 0-1298-206 25 FT CORD w/gfci UL Models 0-1295-200, 0-1296-200, 0-1297-200, 0-1298-200

More information

Potable Water Convertible Jet Pumps

Potable Water Convertible Jet Pumps Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. Register your Zoeller Pump

More information

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft Bulletin No. BK4755 (11/07) 1-70 Series End-Mount Brake Instructions NEMA 2 Enclosure Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. PEDESTAL SUMP PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1084-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

STEP-BY-STEP INSTALLATION GUIDE

STEP-BY-STEP INSTALLATION GUIDE Battery Backup System STEP-BY-STEP INSTALLATION GUIDE Operating Instructions & Parts Manual ESP25 Please read and save these instructions. Read carefully before attempting to assemble, install, operate

More information

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

MH Series - Horizontal Multistage Pump OWNER'S MANUAL MH Series - Horizontal Multistage Pump OWNER'S MANUAL BEFORE YOU START BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. REFER TO PRODUCT DATA PLATE(S) FOR ADDITIONAL OPERATING INSTRUCTIONS

More information

Sump / Effluent Pump

Sump / Effluent Pump Operating Instructions and Parts Manual SEF40V, SEF40V-2, SEF40T, SEF40T-2, SEF40D, SEF40D-2, SEF40M The Professional s Line Please read and save these instructions. Read carefully before attempting to

More information

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

3 FT CORD Models , , , FT CORD W/GFCI Models , , , POWERLINE XP II Swimming Pool Pump (Light Oak color model) With Automatic Timer 3 FT CORD Models 0-1395-226, 0-1396-226, 0-1397-226, 0-1398-226 25 FT CORD W/GFCI Models 0-1395-220, 0-1396-220, 0-1397-220,

More information