Crystal Quest UltraViolet Disinfection System INSTALLATION AND OPERATION GUIDE
|
|
- Shauna Alexina Lloyd
- 6 years ago
- Views:
Transcription
1 Crystal Quest UltraViolet Disinfection System INSTALLATION AND OPERATION GUIDE MODELS: CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM Copyright 2017 Crystal Quest All rights reserved MADE IN THE USA COMPONENTS
2 TABLE OF CONTENTS Important Information...2 Safety Precautions...3 Water Conditions...3 Diagram of UV Lamp...4 Installation/Location...4 Installation Instructions...5 UV Installation (Whole House)...6 UV Installation (Other)...6 Operation and Specifications Chart Operation and Maintaince...7 Quartz Sleeve Replacement and/or Cleaning...7 One-Year Limited Warranty...8 OPERATING SPECIFICATIONS: Pressure Range: psi ( bar) Temperature Range: F ( C) Optimum Service Flow: 1-84 gpm ( lpm) The system should be installed by a licensed plumber in any state or country. Specifically, the following states require a licensed plumber OR allow a state-registered installer or contractor to install your water filter system: AR, CA, GA, KS, MA, MI, MN, OK, RI, SC, SD, TX, VT, and WI. All drawings, pictures, colors and sizes are approximate for illustrative purposes only and may not exactly resemble the end product. 2 IMPORTANT INFORMATION A qualified licensed plumber should install this Ultraviolet (UV) Disinfection System. Not using the service of a qualified plumber could void warranty. Inspect the carton and Ultraviolet Disinfection System for evidence of rough handling and concealed damages. If contents appear damaged, ask driver or contact the carrier for a damage claim form to fill out. Notify shipper immediately. Remove components from the shipping carton. Check that all installation parts and hardware are present. Make a complete inspection of the UV Disinfection System to ensure that: a) there are no physical damages to the system, b) all accessories are present, c) and the system is clean and dust free. Read all instructions, specifications, cautions, and warnings before installing and using your water filter system. Intended for indoor use only. When storing the unit, drain all water from it and disconnect it from water supply. The use of attachments not recommended or sold by the manufacturer/distributor may cause an unsafe condition. Installation errors can cause property damage. Crystal Quest assumes no liability whatsoever for systems improperly installed or those installed by someone other than a licensed plumber or qualified contractor. Use the system on a potable, safe-to-drink, COLD water supply only. Do not use the system where water is microbiologically unsafe or with water of unknown quality. Turn the cold water line off while installing the system. When installation is complete, recheck the system to ensure there are no leaks or drips. The UV system should be installed to meet local, state and federal plumbing codes and health department rules and regulations. All water treatment installations must conform to local plumbing, electrical and sanitation codes. These codes are established for your protection. Check with your local public works department for current plumbing codes.
3 SAFETY PRECAUTIONS WARNING To guard against injury, basic safety precautions should be observed, including the following: Read all instructions, specifications, cautions, and warnings before installing and using your UV Disinfection System. Learn the specific details regarding installation and use. Failure to follow them could cause serious property damage. DANGER To avoid possible electric shock, special care should be taken since water is present near electrical equipment. Carefully examine the UV Disinfection System after installation. It should not be plugged in if there is water on parts not intended to be wet. The outlet to plug in the UV Disinfection System must be within reach of the power cord. Do not use an extension cord. Extension cords that are too long or too light do not deliver sufficient voltage to the unit and could present a safety hazard. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the disinfection system rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled. Do not operate the UV Disinfection System if it has a damaged cord or plug, if it is malfunctioning, or if it has been dropped or damaged in any manner. Always disconnect water flow and unplug the disinfection system before preforming any cleaning or maintenance activities. Never yank the cord to remove from an outlet; grasp the wall plug and pull to disconnect. NOTE The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually. Installation must be made within an area protected from the elements and freezing. The unit must be protected from rain, dust, flooding, snow, freezing, and direct sunlight (the system s exposure to direct sunlight may cause algae growth). Failure to comply will void the warranty. WARNING: The light given off by this unit can cause serious burns to unprotected eyes and skin. Never look directly at a burning UV lamp. When performing any work on the UV Disinfection System, always unplug the unit first. Never operate the UV system while the UV lamp is outside of the UV chamber. WATER CONDITIONS Feedwater quality is extremely important for the optimum performance of your UV Disinfection System. The following levels are recommended for installation: Turbidity: < 1 NTU Hardness*: < 7 gpg (120 mg/l) Iron: < 0.3 ppm (0.3 mg/l) Manganese: < 0.05 ppm (0.05 g/l) Tannins: < 0.1 ppm (0.1 mg/l) UV Transmittance: > 75% (call for recommendations on applications where UVT < 75%) * Where total hardness is less than 7 gpg, the UV Disinfection System should operate efficiently provided the quartz sleeve and/or sensor probe is cleaned periodically. If total hardness is over 7 gpg, the water should be softened. If your water contains levels in excess of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of your UV Disinfection System. These water quality parameters can be tested by your local dealer or by most private analytical laboratories. Proper pretreatment is essential for the UV Disinfection System to operate as intended. Water testing by an independent third-party lab will attest to microbiologically toxic-free disinfected water. California residents are advised to have their water tested to ensure the water filter system is in compliance with Proposition 65. 3
4 DIAGRAM OF UV LAMP (CQE-PT-03269) 1 Gland Nut (CQE-PT-03270) 2 Inlet 3 Outlet 4 Stainless Steel Reactor Chamber (CQE-PT-03268) 5 O-Rings (CQE-PT-03150) 6 Quartz Sleeve (CQE-PT-03101) 7 Bulb (CQE-PT-03267) 8 Ground Wire (CQE-PT-03089) 9 Lamp Connector 10 Ballast 11 Power Supply Plug INSTALLATION/LOCATION CAUTION Electronic ballast must be connected to a grounded outlet (see GFCI) and the lamp connector ground wire connected to the stainless steel reactor chamber. The disinfection system is designed to be mounted horizontally or vertically at the point of use or point of entry depending on the specific flow rate of the unit (see UV installation diagram, Page 4). NOTE The ideal installation is vertical with the lamp connector on top. This prevents water damage from occurring on the lamp pins and lamp connector (see UV installation diagram, Page 4). The ballast should be mounted either above or beside the reactor chamber. This prevents moisture from entering the ballast enclosure and minimizes the potential for ballast failure. The complete water system, including any pressure or hot water tanks, must be sterilized before start-up by flushing with chlorine (household bleach) to destroy any residual contamination. For safety purposes, the UV Disinfection System should be connected to a ground fault circuit interrupter. If treating the entire house, install the disinfection system before any branch lines. A 5-micron sediment filter must precede the UV Disinfection System. Ideally, the UV Disinfection System should be the last treatment the water receives before it reaches the faucet. Test once a month to make sure GFCIs are working properly and are protecting you from fatal shock. To test the receptacle GFCI, first plug a nightlight or lamp into the outlet. The light should be on. Then, press the TEST button on the GFCI. The GFCI s RESET button should pop out and the light should go out. If the RESET button pops out but the light does not go out, the GFCI has been improperly wired. Contact an electrician to correct the wiring error. If the RESET button does not pop out, the GFCI is defective and should be replaced. If the GFCI is functioning properly, and the lamp goes out, press the RESET button to restore power to the outlet. 4
5 INSTALLATION INSTRUCTIONS 1. Carefully remove the UV lamp from the shipping tube, being careful not to touch the glass portion with your fingers. The UV Disinfection System should be mounted in the horizontal position with the inlet/outlet ports facing up. If the system must be installed in the vertical position, make sure the inlet port is at the bottom of the system. Mount the unit in a clear space with at least 40 (100 cm) of space at the lamp end to facilitate lamp and/or quartz sleeve removal. Fasten the UV Disinfection System to a suitable mounting platform with secure fasteners. Apply two turns of thread seal tape around the port threads to ensure a tight joint. 2. Insert the UV lamp into the quartz sleeve and chamber, making sure the lamp pins are accessible for connection with the lamp connector cable. Attach the lamp connector to the lamp pins and press firm into gland nut. Mount the UV Disinfection System with the supplied clamp. If the UV Disinfection System is to be hard plumbed, leave enough clearance in front of the lamp connector to allow for lamp service (a length equal to the length of the unit should suffice). 3. Various connection methods can be used to connect the water source to the UV Disinfection System; however, union type connectors are recommended. The use of a flow restrictor device is strongly recommended when installing your disinfection system, in order that the recommended flow rate not be exceeded. In addition, the use of a bypass assembly is recommended for emergency use of untreated water when your disinfection system is being serviced. 4. Prior to connecting the power source, check all connections to ensure that they are indeed secure; turn on water supply and check for any leaks. If satisfied that there are no leaks, proceed with the followings steps. DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE DISINFECTION SYSTEM. THIS COULD DAMAGE THE O-RING SEALS. 5. To properly ground the stainless steel reactor chamber, attach the green wire coming from the power source to the grounding lug on the UV chamber. Remove the green cap nut and slide the eyelet connector onto the screw. Fasten the cap nut to the screw with a 5/16 wrench. 6. The power source provided with your disinfection system must be located within 5 feet of an electrical outlet. DO NOT USE AN OUTLET THAT CAN BE SWITCHED OFF (ie. A WASTE DISPOSAL OUTLET). Attach the lamp connector to the UV lamp and press into the gland nut. Plug the ballast into the outlet and ensure the POWER-ON LED is illuminated. NEVER LOOK DIRECTLY AT THE BURNING UV LAMP. THE LIGHT GIVEN OFF BY THIS UNIT CAN CAUSER SERIOUS BURNS TO UNPROTECTED EYES AND SKIN. When power is first applied, th ballast will enter an audible self- test mode. NOTE If ballast enters alarm condition, power must be removed for 30 seconds to allow ballast to reset. NOTE The UV Disinfection System requires time to reach its full operating capacity. Allow the disinfection system to operate 3-5 minutes prior to use. In addition, open the faucet and allow water to run through the UV Disinfection System for 2-3 minutes to clear any air or debris. When using a reverse osmosis (RO) application, run the water for seconds. NOTE When the UV unit is returned to service after being on bypass, the complete water system must be resterilized with chlorine (household bleach) to destroy any contamination that may have entered the distribution system while on bypass. CONNECTING UV TO GALVANIZED PIPE GALVANIZED PIPE OR NIPPLE CONNECTING UV TO PLASTIC PIPE PLASTIC PIPE OR NIPPLE ULTRAVIOLET ULTRAVIOLET SOLVENT BOND FITTINGS OUTLET OUTLET INLET INLET 5
6 OUTSIDE TAP WATER UV INSTALLATION (WHOLE HOUSE) (UV PLACEMENT IS OPTIONAL BASED ON WATER FEED SOURCE.) COLD WATER HOT WATER OPTIONAL ULTRAVIOLET BULB POST-FILTER BYPASS PRE-FILTER OPTIONAL ULTRAVIOLET BULB For a P.O.E. system installation, refer to the Point of Entry Whole House Water Filter System Installation and Operation Guide. Download a copy from Pipe, shut-off valves, and fittings are not provided by Crystal Quest. WATER HEATER TANNIN SOFTENER BRINE TANK WATER METER WATER SUPPLY CAUTION UV LIGHT DO NOT LOOK DIRECTLY AT LIGHT UV INSTALLATION (OTHER) Triple Undersink with a 1 GPM Ultraviolet Water Sterilizer System CQE-US Thunder Reverse Osmosis / Ultrafiltration 3000C with 1 GPM Ultraviolet Water Sterilizer System CQE-RO Point-of-Use Bottleless Water Cooler with 1 GPM Ultraviolet Water Sterilizer System CQP-WC MODEL WATTS ELECTRICAL VOLTS ELECTRICAL Hz OUTPUT POWER HOUSING MATERIAL SS DOSAGE uw/cm 2 INLET/OUTLET PORT SIZE MNPT AUDIBLE LAMP FAILURE MAXIMUM PRESSURE LBS CQE-UV GPM 11W mA 304# >30000 ¼ YES 85 CQE-UV GPM 25W mA 304# >30000 ½ YES 100 CQE-UV GPM 30W mA 304# >30000 ½ YES 100 CQE-UV GPM 55W mA 304# >30000 ¾ YES 100 CQE-UV GPM 110W mA 304# > YES 100 CQE-UV GPM 165W mA 304# > YES 100 CQE-UV GPM 220W A 304# > YES 100 CQE-UV GPM 275W A 304# > YES 100 CQE-UV GPM 330W A 304# > YES 100 CQE-UV GPM 440W A 304# > YES 100 6
7 OPERATION AND MAINTENANCE NOTE PRIOR TO PERFORMING ANY WORK ON THE DISINFECTION SYSTEM, ALWAYS DISCONNECT THE POWER SUPPLY FIRST. 1. Regularly inspect your disinfection system to ensure that the UV lamp is operating. 2. Replace the UV lamp with a new lamp after one year of continuous use to insure a high bacteria and virus kill rate. NOTE The UV lamp should be ON continuously. Repeatedly turning the lamp on and off will severely shorten the lamp life and allow bacteria to pass through without being affected by the UV. TO REPLACE the UV lamp, first disconnect power. Disconnect the lamp connector by carefully separating it from the gland nut (use the aid of a slot screwdriver, if required). Disconnect lamp connector from lamp and carefully remove the UV lamp. Replace the new lamp, being careful not to touch the new UV lamp glass with your fingers as oils may impair UV transmission. If contact does occur, clean lamp with alcohol and reconnect lamp connector. Carefully replace lamp into stainless steel chamber. Press lamp connector into aluminum gland nut. Plug power source into outlet. Verify POWER-ON LED is illuminated and audible ballast start-up sequence operates. If the water contains any hardness minerals (calcium or magnesium), iron or manganese, the quart sleeve will require periodic cleaning. To remove the quartz sleeve, first remove the UV lamp (see instructions on replacing quartz sleeve) and follow these steps: 1. Shut off water supply and drain all lines. 2. Remove the lowest connection on the disinfection system and drain the UV chamber (use a small bucket under the unit to prevent a spill). 3. Remove gland nuts from chamber (do not allow quartz sleeve to fall). 4. Carefully remove O-rings from the quartz sleeve. As the O-rings may tend to adhere to the quartz sleeve, it is recommended to replace the O-rings annually. 5. Clean the quartz sleeve with a cloth soaked in vinegar or some other mild acid and then rinse. 6. Reassemble to quartz sleeve in the UV chamber, allowing the sleeve to protrude an equal distance from both ends of the UV chamber. 7. Wet the O-rings and slide onto each end of the quartz sleeve, then reassemble the gland nuts (hand tight is sufficient). 8. Retighten all connections, turn on water and check for leaks. 9. Reinstall the UV lamp and lamp connector as per prior instructions. 10. Plug in ballast and verify the POWER-ON LED is illuminated and ballast power-up sequence operates. NOTE IF THE SYSTEM IS PUT ON A TEMPORARY BYPASS OR IF IT BECOMES CONTAMINATED AFTER THE DISINFECTION SYSTEM, IT WILL BE NECESSARY TO SHOCK THE SYSTEM WITH HOUSEHOLD BLEACH FOR A FULL 20 MINUTES BEFORE RESUMING THE USE OF THE WATER. QUARTZ SLEEVE REPLACEMENT AND/OR CLEANING 1. Mineral deposits and sediment may accumulate on the quartz sleeve, decreasing UV output. Good maintenance of filtration equipment will reduce the accumulation of residues. If necessary, remove the quartz sleeve after a few months and clean with a commercially available scale remover (CLR, Lime-Away, etc.) and lint free cloth. Repeat the process as often as necessary to keep the quartz sleeve clean. 2. Disconnect power to remove the quartz sleeve. Disconnect the UV lamp and remove from the UV chamber. The sleeve can be removed in the same manner as the UV lamp (through the end of the disinfection system) or by removing the entire cell. 3. Remove the aluminum gland nuts and the two O-ring seals. 4. Carefully slide the quartz sleeve out of the chamber (either side), being careful not to let the end drop inside the chamber which could accidentally crack the quartz. When reassembling the quartz sleeve, make sure the sleeve protrudes an equal distance at each end of the cell. 5. Wet the O-rings with water with any non-petroleum oil and slide onto each end of the sleeve. 6. Reinstall the gland nuts and hand tighten to achieve a watertight seal. 7. Install the lamp and connect the lamp connector. Press the connector into the gland nut. Slowly turn on water and verify there are no leaks. Reconnect to power source. 7
8 ONE-YEAR LIMITED WARRANTY KEEP THIS MANUAL FOR FUTURE REFERENCE AND UNIT MAINTENANCE Online warranty information Product design is subject to change without notice. For further assistance, contact your Crystal Quest dealer or visit us at To view the latest edition of the UltraViolet Disinfection System Guide, visit CrystalQuest.com YOUR PURCHASE INFORMATION CRYSTAL QUEST warrants your CRYSTAL QUEST UltraViolet Disinfection System for one year from the date of purchase against all defects in materials and workmanship when used in compliance with the manual. This warranty does not include replacement cartridges unless defective upon receipt. CRYSTAL QUEST disclaims all implied warranties including, without limitation, warranties of merchantability and fitness for a particular purpose. If for any reason the product proves to be defective within one year from the date of purchase, please call for assistance. This warranty gives you specific legal rights and you may have other legal rights which vary from state to state. CRYSTAL QUEST assumes no responsibility for incidental or consequential damages, for damages arising out of misuse of the product, or the use of any unauthorized attachment. Some states do not allow the exclusion or limitation of implied warranties or incidental or consequential damages; therefore, the above limitations or exclusions may not apply to you. Should service be required during or after the warranty period or should you have any questions regarding how to use your CRYSTAL QUEST UltraViolet Disinfection System, please contact our Technical Support Department at service@crystalquest.com, Monday through Friday, 9 AM to 5 PM Eastern Time. Please record the information below for your future reference Plumber s Name Plumber s Address Plumber s Telephone INFORMATION & ASSISTANCE For questions about your order or general comments or questions: UV REPLACEMENT LAMPS CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM Customer Service For Technical Support and Product Information Hours of Operation: Monday through Friday, 9 AM to 5 PM Eastern Time support@crystalquest.com CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM CQE-UV GPM 8
9 AUTHORIZED DISTRIBUTOR Should service be required during or after the warranty period or should you have any questions regarding how to use your Commercial Water Purification System, please contact manufacturer s Technical Support Department Monday through Friday, 9 AM to 5 PM Eastern Time, or your authorized CRYSTAL QUEST dealer: Mailing Address: FilterWater.com P.O. Box 968 Southampton, PA USA Tel. +1 (800) Fax +1 (215) Sales@filterwater.com 9
Crystal Quest Ultraviolet Disinfection System Installation and Operation Guide
Crystal Quest Ultraviolet Disinfection System Installation and Operation Guide OPERATING SPECIFICATIONS Pressure Range: Temperature Range: Optimum Service Flow: 30-60 psi (2.1-4.1 bar) 40-100ºF (4.4-37.7ºC)
More informationUltraviolet Sterilization System Installation Instructions & Owner s Manual
Your best choice in Ultraviolet Sterilization RoHS COMPLIANT Ultraviolet Sterilization System Installation Instructions & Owner s Manual For models: UV-1, UV-2, UV-6, UV-8C, UV-12C, UV-24B UV-100B Table
More informationONLINE WARRANTY INFORMATION CrystalQuest.com/warranty.html
Crystal Quest Point-of-Entry (POE) Whole House Compact Water Filter Systems INSTALLATION AND OPERATION GUIDE ONLINE WARRANTY INFORMATION CrystalQuest.com/warranty.html Copyright 2018 Crystal Quest All
More informationULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL
ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL GUV-SHIELD, GUV-SHIELD-MAN SERIES UV Systems Model numbers: GUV-7 GUV-SHIELD-7 GUV-SHIELD-7-MAN GUV-SHIELD-10 GUV-SHIELD-10-MAN GUV-SHIELD-15
More informationLaboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!
Laboratory Series Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual KEEP THIS MANUAL ON HAND IT IS IMPORTANT THAT THOSE RESPONSIBLE FOR THE INSTALLATION OF THIS EQUIPMENT,
More informationOWNER'S MANUAL PURIFY WATER 99.99% FREE OF BACTERIA AND VIRUSES! Model IHS12-D4 and IHS12-D4/2 WHOLE HOME UV DISINFECTION SYSTEM
WHOLE HOME UV DISINFECTION SYSTEM Model IHS-D4 and IHS-D4/ OWNER'S MANUAL PURIFY WATER 99.99% FREE OF BACTERIA AND VIRUSES! Congratulations. By purchasing this system, you have taken the first step in
More informationWEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP SERIES NO'S
INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT SERIES NO'S 1 2 4 7 Sold by: Manufactured by: WEDECO Ideal Horizons, Inc. 3520 Westinghouse
More informationgamma uv Aquarium Ultraviolet Sterilizers
gamma uv Aquarium Ultraviolet Sterilizers Instructions for Models #1400 8w, 1401 15w, 1402 25w Important Safety Instructions... Page 2 Installation... Page 3 8/15/25 watt Alternate Diagrams... Page 5 25
More informationInstallation & Service Manual
Installation & Service Manual Table of Contents Unpacking and Inspection... 3 Specifications... 3 Installation Directions... 3 Product Installation Sequence... 4 Replacing EWUV Bulb... 4 Servicing EWUV
More informationINSTALLATION INSTRUCTION & OWNER S MANUAL
CS-2500 & CS-2500P Water Filtration System INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 1.2 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful
More informationOwner s Manual. PUV-Basic PUV-8 PUV-16. (NSF Standard 55 Class B Certified)
Owner s Manual PUV-Basic PUV-8 PUV-16 (NSF Standard 55 Class B Certified) Congratulations. By purchasing this system, you have taken the first step in ensuring safe drinking water. Designed using the most
More informationOwner s Manual. Models: VT1, VT1/2, VT1/2A, VT1/2B, VT1/12 VT4, VT4/2, VT4/2A, VT4/2B, VT4/12. Powered by _RevP
Owner s Manual Models: VT, VT/, VT/A, VT/B, VT/ VT4, VT4/, VT4/A, VT4/B, VT4/ Powered by 45 Clair Rd. W, Guelph, Ontario, Canada NL R t. (+) 59.76.0 tf. (+) 800.65.746 (US and Canada only) t. (+) 7 747
More informationOPERATIONS AND MAINTENANCE MANUAL EcoStream Models ECS60R / ECS100R / ECS150R
OPERATIONS AND MAINTENANCE MANUAL EcoStream Models ECS60R / ECS100R / ECS150R 2 TABLE OF CONTENTS TABLE OF CONTENTS... 3 SAFETY INSTRUCTIONS... 4 OVERVIEW... 5 Reactor Chamber... 5 Control Panel... 5 Standard
More informationMULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS
MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS Model #: 30101 Model #: 30102 Replacement Cartridge INSTALLATION GUIDE ABOUT THIS SYSTEM Congratulations on your purchase of the 30101 Multi-Stage
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual IOM-WQ-SmartStream-A 254 Nanometer Germicidal UV Disinfection Systems Models WA002 WA006 WA008 WA012 SmartStream UV Chemical Free Disinfection of Water Read
More informationUsers Manual Certified Series Direct Drive Pump 1-7 LPM
Users Manual Certified Series Direct Drive Pump 1-7 LPM Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232 www.fogco.com
More informationInstallation, Operation and Maintenance Manual
IOM-HS-QTColdBevMax Installation, Operation and Maintenance Manual QT TM Cold Bev Max TM Models: QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M Tested and Certified
More informationFull Flow Drinking Water System Model: 3MFF100
Installation and Operating Instructions For Full Flow Drinking Water System Model: 3MFF100 System tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of the
More informationInstallation, Operation and Maintenance Manual
IOM-HS-QTCubeMax Installation, Operation and Maintenance Manual QT TM Cube Max TM Models: QTCBMX-1S-1M, QTCBMX-2S-1M, QTCBMX-3S-1M, QTCBMX-4S-1M, QTCBMX-1L-1M, QTCBMX-2L-1M, QTCBMX-3L-1M, QTCBMX-4L-1M,
More informationPURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important.
Installation, Operation and Maintenance Manual 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG IOM-WQ-PWSYS-UV-3STG PURE WATER Important Please read the entire manual before proceeding with
More informationOWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP
Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475
More informationINSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01
INSTALLATION GUIDE Rainier Coil Pull Down Kitchen Faucet PB-K01 RECOMMENDED TOOLS AND MATERIALS Plumbers Putty Adjustable Wrench Tape Measure Basin Wrench Phillips Screwdriver Pencil Masking Tape BEFORE
More informationINSTALLATION GUIDE. Tenino Retro Pot Filler Hi-Rise Kitchen Faucet PB-K05
INSTALLATION GUIDE Tenino Retro Pot Filler Hi-Rise Kitchen Faucet PB-K05 RECOMMENDED TOOLS AND MATERIALS Sink Hole Cover (Optional) Allen Wrench Set Plumbers Putty Adjustable Wrench Tape Measure Basin
More informationPACIFICA Shower Cabin Installation Instructions
PACIFICA Shower Cabin Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower cabin. If you have any questions on this shower cabin installation
More informationOwner s Manual. Powered by. Models: VH200-F10, VH410-F R_RevG
Owner s Manual Models: VH00-F0, VH40-F0 Powered by 45 Clair Rd. W, Guelph, Ontario, Canada NL R t. (+) 59.763.03 tf. (+) 800.65.746 (US and Canada only) t. (+3) 73 747 044 (Europe only) f. (+) 59.763.5069
More information- Do not Discard these instructions; please save them for later use/reference.
Customer Support: Tel: 1-347-492-4014 Email: info@pureeffectfilters.com www.pureeffectfilters.com Thank you, and Congratulations on your purchase of The PureEffect TM ULTRA-DISINFECT Water Filtration System
More informationIno Single Handle Basin Bathroom Faucet
INSTALLATION GUIDE Ino Single Handle Basin Bathroom Faucet KEF-15701 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations on the purchase of your new
More informationINSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS
INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES INTRODUCTION DESCRIPTIONS AND DEFINITIONS CONDITIONS FOR USE
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Ultraviolet Single and Dual Germicidal Lamps 60 Hz Part Numbers: P103-UVLTT1LP1020A01, P103-UVLTT1LP3020A01, P103-UVLTT2LP1020A01, P103-UVLTT2LP3020A01 SAFETY CONSIDERATIONS Installation
More informationINSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS Rev. 07/16
INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES 36103017 Rev. 07/16 TABLE OF CONTENTS INTRODUCTION DESCRIPTIONS
More informationAQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter
The world leader in products for a healthy and comfortable environment - bringing the Garden of Eden into your home. AQUA2000 OWNER S MANUAL INCLUDES: Restrictions Installation Operation Maintenance Changing
More informationAquila Single Lever Vessel Faucet
INSTALLATION GUIDE Aquila Single Lever Vessel Faucet FVS-13900 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 24, 2017 Congratulations on the purchase of your new Kraus
More informationAQUA2000 From O3PURE
AQUA2000 From O3PURE OWNER S MANUAL INCLUDES: RESTRICTIONS INSTALLATION OPERATION MAINTENANNCE CHANGING THE FILTER CHANGING THE UV LAMP SPECIFICATIONS WARRANTY ADVANCED WATER TREATMENT SYSTEMS CAUTION:
More informationINSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS Rev. 5/10
INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES 36103017 Rev. 5/10 TABLE OF CONTENTS INTRODUCTION DESCRIPTIONS
More information(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.
OPERATOR S MANUAL 12 VOLT LITHIUM-ION BATTERY CHARGER 140446001 (R86049) Your charger has been engineered and manufactured to our high standards for dependability, ease of operation, and operator safety.
More informationULTRAVIOLET STERILIZER
INSTALLATION MANUAL ULTRAVIOLET STERILIZER 2,000 and 2,000+ Hanger Model 2,000 and 2,000+ Barb x Barb Model 42371 Avenida Alvarado, Temecula, CA 92590 TOLL FREE: (800) 454-2725 TEL: (951) 296-3480 FAX:
More informationSignature Series Filter Manual
Signature Series Filter Manual Installation / Operation Manual Fully Automatic Water Filter Filter Specifications...Page 3 Installation Requirements...Page 4 Installation Procedures...Page 5 Error Codes...Page
More informationSafety, Installation and Service Manual Models 1952, 1953 & 1972
Ultraviolet Germicidal Lamps Model 1952 24 Rooftop Unit Model 1953 32 Rooftop Unit Model 1972 Rooftop Unit, Internal Mount Safety, Installation and Service Manual Models 1952, 1953 & 1972 READ AND SAVE
More informationSubmersible Pond Pump with UV 800 Gallons Per Hour
Submersible Pond Pump with UV 800 Gallons Per Hour REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PP800UV Questions, problems, missing parts? Before returning to your retailer,
More informationFor safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.
NANO INDUCT Owner s Manual For use with models: NIND14, NIND9, NIND6 For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit. Thank You for
More informationHQUA. UV Water Sterilizer Instruction Manual. Contents
UV Water Sterilizer Instruction Manual Contents Section 1 Safety Information 2-3 Section 2 General Information.4-7 Section 3 Maintenance.7-9 Section 4 Troubleshooting.10 Section 5 After-Sales Service...10
More informationOwner s Manual WARNING
Filter Housing Models: AWP20C-V, AWP30C-V, AWP32B-V. Overview: Owner s Manual VIQUA offers a variety of housing sizes and styles in durable, molded polymer that defies rust and corrosion, and ensures a
More informationSingle Lever Pull-Out Kitchen Faucet
INSTALLATION GUIDE Single Lever Pull-Out Kitchen Faucet KPF-1621 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations on the purchase of your new Kraus
More informationHydrosafe - Model HSFS
Hydrosafe - Model HSFS Whole House Filtration and Water Treatment Triple-Treat Protection Three-In-One Technology The innovative HydroSafe filtration system incorporates three technologies in one unit
More informationOwner s Manual. Installation, Operation & Maintenance Read and Follow All Safety Instructions. Save These Instructions. Ballast 230v 50/60Hz
Models Ballast 120v 50/60 Hz Ballast 230v 50/60Hz Ballast 12v DC BIO 1.5 PWP 10-0518A 10-0514A 10-1201A Installation, Operation & Maintenance Read and Follow All Safety Instructions. Save These Instructions.
More informationUV-AIRE AIR PURIFYING SYSTEM
UV-AIRE AIR PURIFYING SYSTEM Model: UV-16/24 The UV-Aire unit is designed to emit powerful UVC Band light rays, which sterilize and reduce airborne microorganisms as they pass through a heating or air
More informationScale Feeder Manifold Water Filtration System Instruction Manual
3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.
More informationModel: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
U V - AIRE AIR PURIFYING S YSTEM Model: UV-16R/24 ITEMS INCLUDED IN KIT: 1-24Volt UV-Aire Ballast Assembly 1-Mounting Base 1-Ultraviolet Lamp 6-Sheet Metal Mounting Screws 1-Instruction Sheet 1-Fiberglass
More informationDual/Triple Manifold Water Filtration Systems Instruction Manual
3M TM Water Filtration Products Dual/Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator. 3M Water
More informationFlow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL
Flow Max Fluid Pump by Duraself OEM INSTALLATION MANUAL TABLE OF CONTENTS System and Safety Information 2 Resources Required 3 Installation 3 General Installation Instructions 3 Mounting Instructions 3
More informationINSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer
INSTALLATION GUIDE KPF-21 Single Lever Kitchen Faucet With Pull-Out Sprayer www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. August 7, 2017 Congratulations on the purchase of your
More informationQUALITY MISTING PUMPS
TOTALLY ENCLOSED DIRECT DRIVE 60030KH, 60031KH, 60050KH, 60051KH 60100KH, 60101KH, 60150KH, 60151KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION,
More informationUS Water Systems Magna Pre-Filter
Visit us online at www.uswatersystems.com US Water Systems Magna Pre-Filter Owners Manual 320-USP-MF-10, 320-USP-MF-20 REVISION # 1.3 REVISION DATE October 9, 2018 US Water Systems Corporate Office 1209
More informationUVME SERIES ULTRAVIOLET WATER TREATMENT SYSTEM. S a f e W a t e r T e c h n o l o g i e s, I n c. 1 LAMP MODELS UVME-1S: 19 GPM, 2 INCH MNPT
S a f e W a t e r T e c h n o l o g i e s, I n c. I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVME SERIES ULTRAVIOLET WATER TREATMENT SYSTEM 1 LAMP MODELS UVME-1S: 19
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationGeo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser
INSTALLATION GUIDE Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser KPF-1702 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations
More informationUS Water ORP Booster Injection System
US Water ORP Booster Injection System US Water Systems, Inc. 1209 Country Club Road Indianapolis, IN 46234 1-800-608-8792 info@uswatersystems.com www.uswatersystems.com REVISION 1.1, 9-14-15 Table of Contents
More informationOperators Manual. Model 3370 Air Cooled Recirculator rev.8/98
Operators Manual Model 3370 Air Cooled Recirculator 110-080 rev.8/98 Table of contents Section 1. General Information 1.1 Warranty 1.2 Unpacking Section 2. Product Information 2.1 Description 2.2 Specification
More informationBottom Loading Water Dispenser
Bottom Loading Water Dispenser Model # 601000 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING DISPENSER. SAVE THIS MANUAL FOR FUTURE
More informationSTOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL
CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning
More informationPortable Sanitizing Wand. Model: VH03. The CleanWave Portable Sanitizing Wand kills up to 99.9% of germs and odorcausing. surfaces.
The CleanWave Portable Sanitizing Wand kills up to 99.9% of germs and odorcausing bacteria on hard surfaces. To Start, Press Until Beep Portable Sanitizing Wand SAVE THESE INSTRUCTIONS Model: VH03 Edit
More informationSingle Lever Pull-Out Kitchen Faucet
INSTALLATION GUIDE Single Lever Pull-Out Kitchen Faucet KPF-1602 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations on the purchase of your new Kraus
More informationOletto Single Lever Bar/Prep Faucet
INSTALLATION GUIDE Oletto Single Lever Bar/Prep Faucet KPF-2600 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. January 23, 2018 Congratulations on the purchase of your new Kraus
More informationBolden Single Handle Commercial Kitchen Faucet
INSTALLATION MANUAL Bolden Single Handle Commercial Kitchen Faucet KPF-1610 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. June 22, 2017 Thank you for your purchase We would
More informationBritt Single Handle Commercial Kitchen Faucet
INSTALLATION MANUAL Britt Single Handle Commercial Kitchen Faucet KPF-1690 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. August 10, 2017 Thank you for your purchase We would
More informationAplos Single Lever Basin Faucet
INSTALLATION GUIDE Aplos Single Lever Basin Faucet KEF-15301 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 25, 2017 Congratulations on the purchase of your new Kraus
More informationLIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light
LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light Installation & Operation Manual This manual covers the following models: LightStick #19300 LightStick Plus #19301 GENERAL This product emits germicidal
More informationVH03 SAVE THESE INSTRUCTIONS
CleanWave deodorizes and eliminates up to 99.9% of viruses (including H1N1), bacteria (including MRSA), allergens*, dust mite and flea eggs from household surfaces. Kills up to 99.9% of germs, viruses
More informationDFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350
DFA Series Rainwater/Graywater Filtration Systems MODELS: DFM-2F-180 DFM-3F-180 DFM-3F-350 DFA-2F-180 DFA-3F-180 DFA-3F-350 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety
More informationWater Dispenser Owner s Manual 100 Series
TM Water Dispenser Owner s Manual 100 Series IMPORTANT: This manual includes important safety material; please read all instructions before plugging power supply cord into receptacle. 1 2 3 Load water
More informationWARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
2 Please read the safety and installation instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Photo-catalytic Air Purifier. WARNING: FAILURE
More informationUV DISINFECTION UNIT MODEL 3G
SALCOR INC. P. O. Box 1090 Fallbrook, CA 92088-1090 Telephone: (760) 731-0745 Fax: (760) 731-2405 INSTALLATION MANUAL UV DISINFECTION UNIT MODEL 3G February, 2011 I. INSTALLATION INSTRUCTIONS WARNING!
More informationStormPro BA Series Sump Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationDual Flow Manifold Systems Instruction Manual
3M TM Water Filtration Products Dual Flow Manifold Systems Instruction Manual For DF1XX and DF2XX High Flow Series manifolds and water filtration systems Installer: Please leave this manual with owner/operator.
More informationDual Port Manifold Water Filtration Systems Instruction Manual
M TM Water Filtration Products Dual Port Manifold Water Filtration Systems Instruction Manual For DP1XX, DP2XX and DPXX High Flow Series Water Filtration Systems Installer: Please leave this manual with
More informationAdvanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS
Advanced PCO System Installation Instructions & Consumer Information Section I. Important Installer Information The Dynamic Advanced Photo Catalytic Oxidation (PCO) System utilizes the latest developments
More informationALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase
ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that
More informationPRE-PLUMBED SEWAGE SYSTEM
PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationPEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.
PEDESTAL SUMP PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1084-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing
More informationDocument No B6 Revised December Atlantic Ultraviolet Corporation
375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com Document No. 98-1124B6 Revised December
More informationInstallation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts
Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems The Fresh-Aire UV Airborne Duct System is designed for installation into commercial HVAC system ducts for
More informationULTRAVIOLET WATER PURIFICATION SYSTEMS
ULTRAVIOLET WATER PURIFICATION SYSTEMS INSTRUCTION MANUAL MODEL: VOLTAGE: SERIAL #: TM NSF/ANSI 55 CLASS A CERTIFIED 2 INSTRUCTION MANUAL Copyright UV Pure Technologies Inc. 2008 All rights reserved. No
More informationG8 Portable Fuel Transfer Pump Owner s Manual
G8 Portable Fuel Transfer Pump Owner s Manual GENERAL INFORMATION This pump is designed for use only with gasoline (up to 15% alcohol blends such as E15), diesel fuel (up to 20% biodiesel blends such as
More informationInstallation and Maintenance Manual
Installation and Maintenance Manual Models: UV-, UV-0, UV-00, UV-00, UV-00, UV-000, UV-000 and UV-000 UV Purification Systems CAUTION - WARNING The ballast and all electrical connections MUST be mounted
More informationProfessional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)
Model T0828 Primary pump 1/HP 200 GPH Head of 20 (6 m) SUBMERSIBLE SUMP DUPLEX SYSTEM Professional Séries Discharge: 1 1/2 ABS DWV pipe Electric cable: 9 piggyback type Oil cooled Cast iron construction
More informationSheven Single Lever Vessel Faucet
INSTALLATION GUIDE Sheven Single Lever Vessel Faucet FVS-1002 www.kraususa.com I Toll Free: 1.800.775.0703 I 2017 Kraus USA Inc. I REV. October 24, 2017 Congratulations on the purchase of your new Kraus
More informationSPC-PANEL Simplex, Single Phase Pump Control Panel
Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner
More informationQUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE
QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed
More informationOWNER S MANUAL SUBMERSIBLE UTILITY PUMP
Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475
More informationOwner s Manual Nitrate Series Salt Based Filter System
Owner s Manual Nitrate Series Salt Based Filter System Page 2 Copyright 2012 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of Pelican Water Systems.
More informationInstallation Instructions
Installation Instructions Accessory Ultraviolet (UV) Germicidal Lamp 1 & 2 Lamp Models 115-v & 208/230-v UV Lamp C03009 Fig. 1 Two Lamp Model UV Lamp NOTE: Read the entire instruction manual before starting
More information50 Ft. Retractable Cord Reel
50 Ft. Retractable Cord Reel with Triple Tap Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
More informationMatala. VersiFlow Series. Instruction and Maintenance Manual
VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and
More informationUSER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting.
USER S GUIDE 2880 SERIES 3 Safety Instructions 4 Product View 4-5 Assembly 5 Operation 6 Maintenance and Care 7 Troubleshooting 7 Replacement Parts 8 Warranty Thanks for buying a BISSELL Perfect Sweep
More informationOwner s Manual GLASSLINED PUMP TANK
Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that
More information801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS
280-600 Send Warranty Product Repairs to: 1025 E. Thompson Ave., Hoopeston, IL 60942-0280. Call Customer Service if you have questions: 1-800-621-5485 A. IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS
More informationInstallation Operation Parts
OWNER S MANUAL BATTERY BACKUP SUMP Installation Operation Parts For further operating, installation or maintenance assistance, Call 98-8-05 PRINTED IN U.S.A. M-8 (/9) RULES FOR SAFE INSTALLATION AND OPERATION
More informationFlow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)
Flow Max Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General Installation Instructions...
More informationTWO HANDLE LAVATORY FAUCET
AquaSource is a registered trademark of LF, LLC. All Rights Reserved. ITEM #000748/000749 TWO HANDLE LAVATORY FAUCET MODEL #F50000NP/F50000CP Français p. Español p. Questions, problems, missing parts?
More information40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /
ITEM #0506882 / 0506883 40 V LITHIUM-ION BATTERY MODEL #KB 240-06 / KB 440-06 Français p. 7 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date AB13786C 1 PRODUCT SPECIFICATIONS Battery
More information