1 BULLETIN 916 November 2008 Cast Aluminum Pressure Blowers Model CA/CABD Direct Drive/Belt Driven

2 CA/CABD Cast Aluminum Pressure Blowers Aerovent s Cast Aluminum Pressure Blowers are the perfect choice for providing low volume, high pressure air for cooling, ventilating and exhaust systems which handle dust, materials or corrosive fumes. These direct drive (CA) or belt driven (CABD) blowers feature heavy duty cast aluminum housings with cast aluminum wheels for extra long life and trouble-free service. Capabilities l Seven housing sizes: 8", 9", 10", 12", 14", 15", and 18" l Airflow capacities to 3,800 CFM l Static pressures to 20" l Arrangements 1, 4, 4HI, and 9 available l Temperatures to 150 F for Arrangements 4 and 4HI and 200 F for Arrangements 1 and 9 Features l Rugged cast aluminum housing is inherently corrosion resistant l Cast aluminum radial blade and backward curved wheels are corrosion and spark resistant Arrangement 4 CA Cast Aluminum Pressure Blower Shown with Optional Weather Hood with Screen l Rotatable to 7 discharge positions l 200,000 hour average life bearings on belt driven units l Round inlet and discharge for easy duct connections l Heavy housings reduce noise levels Applications l Laboratory fume hood exhaust l Polishing and grinding machine dust removal l Welding fume exhaust l Combustion air supply l Raw materials, waste, and fibers conveying l Drying processes l General exhaust applications Arrangement 4 CA Cast Aluminum Pressure Blower Shown with Optional Inlet and Discharge Flanges Type B Backward Curved Wheel Type R Radial Blade Wheel 2 Aerovent Bulletin 916

3 Dust Collecting & Pneumatic Conveying Pneumatic conveying embraces both dust collecting and conveying. In a typical system the amount of material transported is low compared to the amount of air used. Usually, a large quantity of fast-flowing air is needed to assure entrainment of material. Consequently, the materials moved have little effect on the performance of the fan. Where the sole purpose of the pneumatic system is to convey as much material as possible, different factors are involved. Dust Collecting & Fume Removal All airborne material, except fumes and the finest of dusts, will settle in ducts and fans if a minimum velocity is not maintained. In dust collecting, the air quantity is determined by the hood size and velocity, therefore it is usually most economical to maintain the lowest duct velocity that will keep the material in suspension. Raising the velocity raises the horsepower. For example, assume 1,000 CFM through a 12" pipe at 1,280 FPM with 0.2" resistance per 100 feet. Doubling the velocity while maintaining the same CFM would require an 8 1 2" pipe at 1.2" resistance per 100 feet. Some state codes give minimum velocities. Where no code applies, the figures shown in Table 1 may be used. When choosing the fan size for a dust collecting system, be certain that the velocity at the fan inlet and outlet is not lower than the minimum velocity required to keep the dust suspended. Material Conveying The problem of inducing the material into a conveying system is often a difficult one. The best overall method is one that feeds the material into the airstream evenly by either mechanical or gravity means. It is often required that the fan pick the material up as well as convey it. One misbelief frequently encountered is that the ability of a system to pick up material is due to the fan s suction pressure. Suction in itself is useless. It is the velocity moving past the material that induces it to flow. For this reason, it is important not to plug up the entrance of the duct with material to be conveyed. When figuring entrance loss to a conveying system, it should be remembered that where an appreciable amount of bulky material is to be moved, it may reduce the effective area of the inlet and thus increase the entrance velocity and loss. Since the purpose of a conveying system is to move a lot of material (as contrasted to dust collecting), the ratio of material to air volume is quite important. Experience has established good minimum velocities for common materials and these are given in Table 2. For those applications not listed, Chart B gives CFM/lb. of material and minimum velocities based on the weight of the material. Table 1. Dust Collecting & Fume Removal Duct Velocities VELOCITY MATERIAL (FPM) 1. Grinding Dust Foundry Sandblast Dust Wood Flour Sander Dust Shavings, Dry SHAVINGS, WET SAWDUST, DRY SAWDUST, WET WOOD BLOCKS HOG WASTE BUFFING LINT, DRY BUFFING LINT, WET METAL TURNINGS LEAD DUST COTTON COTTON LINT WOOL JUTE LINT JUTE DUST GRAIN DUST SHOE DUST RUBBER DUST RUBBER BUFFINGS BAKELITE MOULDING POWDER BAKELITE MOULDING DUST OVEN HOOD TAIL PIPE EXHAUST MELTING POT & FURNACE METALLIZING BOOTH SOLDERING FUMES PAINT SPRAY CARBON BLACK PAPER Table 2. Material Conveying Duct Velocities VELOCITY MATERIAL (FPM) 1. WOOD CHIPS RAGS GROUND FEED POWDERED COAL SAND WOOD FLOUR SAWDUST HOG WASTE PULP CHIPS WOOD BLOCKS CEMENT COTTON WOOL JUTE HEMP VEGETABLE PULP, DRY PAPER FLOUR SALT GRAIN COFFEE BEANS SUGAR Aerovent Bulletin 916 3

4 Dust Collecting & Pneumatic Conveying Wherever material is airborne, the fan must provide the energy to move the material. In small concentrations this is negligible, but in most conveying systems it is important. It is reflected as an increased resistance. Chart A gives the ratio of friction loss of the conveying system to the same system handling clean air The material conveying capacity of a system varies as the square of the velocity since it is a function of the velocity pressure. The economics of a given installation determine whether the minimum or a higher velocity shall be used. It is sometimes thought that a larger fan is naturally better than a smaller one. This is far from correct, since material is just as liable to settle in a fan as in a duct. If the inlet and outlet velocities of a fan are at least as high as the minimum conveying velocity, no settling should occur in the fan. Abrasion & Corrosion Certain materials can be highly abrasive by nature and, depending on the concentration and properties of the abrasive, can greatly affect the selection of the type of fan and wheel design. Proper fan and wheel selection alone may not satisfy the abrasive conditions. Special abrasive, impact, corrosion, and heat resistant materials or coatings may be required to further increase the life of the fan. Although Aerovent has the experience to recommend various materials or coatings to increase the life of the product, it must be recognized that to date no materials have been discovered that completely resist these conditions. Therefore, resistance to them is one of degree only. Chart A. Friction For Conveying FRICTION MULTIPLIER MULTIPLY FRICTION FOR CLEAN AIR BY MULTIPLIER CUBIC FEET OF AIR PER MINUTE PER POUND OF MATERIAL Chart B. Average Velocities & Air Volumes For Conveying Materials CONVEYING VELOCITY IN FT. PER MIN CU. FT. OF AIR PER LB. OF MATERIAL VALUES ARE FOR BULK MATERIALS OF AVERAGE SURFACE CONDITION. WEIGHTS ARE NOT DENSITIES. CONVEYING VELOCITY FT. PERMIN. CU. FT. OF AIR PER LB. OF MATERIAL BULK WT. OF MATERIALS IN LBS. PER CU. FT. Spark-Resistant Construction Described below are three classifications as defined by AMCA Standards for spark resistant construction. Type A B C Construction Details All parts of the fan in contact with the air or gas being handled shall be made of nonferrous material. Steps must also be taken to ensure that the impeller, bearings, and shaft are adequately attached and/or restrained to prevent a lateral or axial shift in these components. Not available in Arr. 4. The fan shall have a nonferrous impeller and nonferrous ring about the opening through which the shaft passes. Ferrous hubs, shafts, and hardware are allowed provided con-struction is such that a shift of impeller or shaft will not permit two ferrous parts of the fan to rub or strike. Steps must also be taken to ensure that the impeller, bearings, and shaft are adequately attached and/or restrained to prevent a lateral or axial shift in these components. The fan shall be so constructed that a shift of the impeller or shaft will not permit two ferrous parts of the fan to rub or strike. NOTES: 1. No bearings, drive components or electrical devices shall be placed in the gas stream unless they are constructed or enclosed in such a manner that failure of that component cannot ignite the surrounding gas stream. 2. The user shall electrically ground all fan parts. 3. For this standard, nonferrous material shall be any material with less than 5% iron or any other material with demonstrated ability to be spark resistant. 4. The use of aluminum or aluminum alloys in the presence of steel that has been allowed to rust requires special consideration. Research, by the U.S. Bureau of Mines and others, has shown that aluminum impellers rubbing on rust steel may cause high intensity sparking. The use of the above standard in no way implies a guarantee of safety for any level of spark resistance. Spark resistant construction also does not protect against ignition of explosive gases caused by catastrophic failure or from any airstream material that may be present in a system. 4 Aerovent Bulletin 916

5 Accessories Belt Guard OSHA belt guard covers the sheaves and belts, protecting personnel from moving drive parts. Solid sheet, painted steel construction. Inlet Filter Filters are recommended where heavy dust conditions exist. Filter housing constructed of carbon steel with baked enamel finish. Polyester, paper, or wire-mesh filter media available as well as a powder coated steel hood. Specify standard stub inlet of fan for mounting. Shaft & Bearing Guard OSHA shaft and bearing guard protects personnel from moving drive parts. Features painted steel construction. Inlet & Outlet Guards Spiral wire type inlet and outlet guards, featuring an electrostatic zinc finish, are offered to protect personnel from the moving parts. Recommended for use when no ductwork is attached to the inlet and/or outlet. Not available on flanged connections. Inlet & Outlet Flange Cast aluminum flanges mount to either the inlet or outlet. Punched flanges, matching ANSI 125/150, are available upon request. Outlet flange not available in downblast discharge configuration. Shaft Seal A shaft seal reduces leakage and protects the bearings and motor from a contaminated airstream. Shaft seals are heavy Teflon type secured to the inside of the fan housing. Housing Drain 1 2" diameter drain connection with plug. Slide Gate Damper Dampers feature cast aluminum frame with galvanized steel gate. Available on inlet or outlet. Slide gate type dampers provide manual adjustment of airflow and flexibility to meet any application. Performance Data Silencer Silencers are designed to reduce noise emanating from the fan inlet. Silencers are constructed of a 2- ply aluminum outer shell over acoustical absorption material and a perforated aluminum core. Silencer has slip-on design for easy mounting to inlet of fan. Not for use with standard inlet filter. Combination inlet filter/silencer is available upon request. Weather Hood Weather Hood with bird screen provides protection from the elements. The enamel-finished steel hood is available for the inlet or outlet. Catalog Numbering System To identify a specific fan for ordering or engineering specifications, it is necessary to show the complete information listed in the performance tables under the catalog number. Specify direct drive or belt drive in addition to the catalog number. All performance data is available in curve form upon request. Housing Size Wheel Design Inlet Diameter Wheel Diameter 12 R Aerovent Bulletin 916 5

6 CA Direct Drive at 3450 RPM (60 Hz) Radial Blade CATALOG SELECTOR 1" SP 2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 8 08R R04A R R04B R R05A R R05B R R05C R R05D R R05E R R06A R R06B R R06C R R06D R R06E R R07A R R07B R R07C R R07D R R07E R R07F R R06A R R06B R R07A R R07B R R08A R R08B R R06C R R07C R R06D R R08C R R07D R R08D R R06A R R06B R R06C R R08A R R10A R R08B R R10B R R08C R R10C R R06A R R08A R R06B R R10A R R06C R R08B R R08C R R10B R R10C CATALOG SELECTOR 9" SP 10" SP 11" SP 12" SP 14" SP 16" SP 18" SP 20" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 12R R07D R R07E R R07F R R07A R R08A R R06A R R06B R R08B R R07B R R06C R R07C R R08C R R06D R R07D R R08D R R06A R R08A R R10A R R06B R R06C R R08B R R10B R R08C R R10C R R06A R R08A R R10A R R06B R R06C R R08B R R10B R R08C R R10C Aerovent Bulletin 916

7 CA Direct Drive at 2850 RPM (50 Hz) Radial Blade CATALOG SELECTOR 1" SP 2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 8 08R R04A R R04B R R05A R R05C R R05D R R05E R R06A R R06B R R06C R R06D R R06E R R06F R R06G R R07A R R07B R R07C R R07D R R07E R R07F R R07G R R06A R R07A R R06B R R08A R R07B R R08B R R06C R R07C R R06D R R08C R R07D R R08D R R06A R R06B R R08A R R10A R R06C R R08B R R10B R R08C R R10C R R06A R R08A R R06B R R10A R R06C R R08B R R10B R R08C R R10C CATALOG SELECTOR 9" SP 10" SP 11" SP 12" SP 13" SP 14" SP 15" SP 16" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 14R R06C R R06D R R07D R R08D R R06B R R08B R R06C R R10B R R08C R R10C R R06B R R06C R R08B R R10B R R08C R R10C Aerovent Bulletin 916 7

8 CA Direct Drive at 3450 RPM (60Hz) Backward Curved CATALOG SELECTOR 1" SP 2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 9 09B B05A B B06A B B06B B B07A B B07B B B06A B B07A B B08A B B06B B B07B B B08B B B06A B B08A B B10A B B06B B B06C B B08B B B08C B B10B B B10C B B06A B B08A B B06B B B10A B B06C B B08B B B10B B B08C B B10C CATALOG SELECTOR 9" SP 10" SP 11" SP 12" SP 14" SP 16" SP 18" SP 20" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 12 12B B07B B B06A B B08A B B07A B B06B B B07B B B08B B B10A B B06A B B08A B B06B B B06C B B08B B B10B B B08C B B10C B B06A B B08A B B10A B B06B B B06C B B08B B B10B B B08C B B10C Aerovent Bulletin 916

9 CA Direct Drive at 2850 RPM (50 Hz) Backward Curved CATALOG SELECTOR 1" SP 2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 9 09B B05A B B06A B B06B B B07A B B07B B B07C B B06A B B07A B B08A B B06B B B07B B B08B B B06A B B08A B B10A B B06B B B06C B B08B B B10B B B08C B B10C B B06A B B08A B B10A B B06B B B06C B B08B B B10B B B08C B B10C CATALOG SELECTOR 9" SP 10" SP 11" SP 12" SP 13" SP 14" SP 15" SP 16" SP NUMBER NUMBER CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 15B B06B B B10B B B08B B B06C B B10C B B08C B B06B B B08B B B06C B B10B B B08C B B10C Aerovent Bulletin 916 9

10 Size 8 CABD Belt Driven Radial Blade VOLUME 0.5" SP 1" SP 1.5" SP 2" SP 2.5" SP 3" SP 3.5" SP 4" SP 4.5" SP 5" SP CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Wheel Diameter: 8.00" O.D. Inlet = 4" Catalog Number = 08R Selector Number = 08R04A Size 9 CABD Belt Driven Radial Blade VOLUME 1" SP 1.5" SP 2" SP 2.5" SP 3" SP 3.5" SP 4" SP 4.5" SP 5" SP 6" SP CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Wheel Diameter: 9.00" O.D. Inlet = 5" Catalog Number = 09R Selector Number = 09R054 Size 10 CABD Belt Driven Radial Blade VOLUME 1" SP 2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP 9" SP 10" SP CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Wheel Diameter: " O.D. Inlet = 6" Catalog Number = 10R Selector Number = 10R06A Size 12 CABD Belt Driven Radial Blade VOLUME 2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP 9" SP 10" SP 12" SP CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Wheel Diameter: 12.25" O.D. Inlet = 7" Catalog Number = 12R Selector Number = 12R07A 10 Aerovent Bulletin 916

11 Size 14 CABD Belt Driven Radial Blade VOLUME 2" SP 4" SP 6" SP 8" SP 10" SP 12" SP 14" SP 16" SP 18" SP 20" SP CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Wheel Diameter: 14.00" O.D. Inlet = 7" Catalog Number = 14R Selector Number = 14R07A Size 15 CABD Belt Driven Radial Blade VOLUME 2" SP 4" SP 6" SP 8" SP 10" SP 12" SP 14" SP 16" SP 18" SP 20" SP CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Wheel Diameter: 15.50" O.D. Inlet = 8" Catalog Number = 15R Selector Number =15R08A Size 18 CABD Belt Driven Radial Blade VOLUME 4" SP 6" SP 8" SP 10" SP 12" SP 14" SP 16" SP 18" SP 20" SP 22" SP CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Wheel Diameter: 18.00" O.D. Inlet = 8" Catalog Number = 18R Selector Number = 18R08A Aerovent Bulletin

12 Dimensional Data Direct Drive Arrangement 4 CA 14 ALSO AVAILABLE WITH 6 AND 8 INLETS CA 15 AND TPB 18 ALSO AVAILABLE WITH 6 AND 10 INLETS ALL MODELS, DISCHARGE FLANGE NOT AVAILABLE FOR DOWN BLAST POSITION. NOTES: 01. CW SHOWN, CCW SIMILAR BUT OPPOSITE 02. SEE R33865 FOR INLET FLANGE AND OPTIONAL OUTLET FLANGE DIMENSIONS. **03. NOMINAL INLET & OUTLET DIAMETER HOUSING A** B C** DIMENSIONS (IN.) D FR G H HA HC HE HG J K L M P Q CA C CA C TC CA C TC C CA TC T CA CA CA T T T T T T T T R33842D DISCHARGE POSITIOn TOP HORIZOnTAL BOTTOM HORIZOnTAL UP BLAST DOWn BLAST TOP 45 o DOWn BOTTOM 45 o UP TOP 45 o UP ROTATIOn CLOCK- WISE COUnTER CLOCK- WISE note: Arrangement 1 - Less Motor Arrangement 9 - With Motor 12 Aerovent Bulletin 916

13 Dimensional Data Direct Drive Arrangement 4HI CA CA 14 ALSO AVAILABLE WITH 5.50 AND 7.50 INLETS CA 15 AND CA 18 ALSO AVAILABLE WITH 5.50 AND 9.69 INLETS HOUSING DIMENSIONS (IN.) FR P CA-8 56C CA-9 56C TC CA-10 56C TC C CA TC T CA T T CA T T CA T T NOTES: 01. CW SHOWN, CCW SIMILAR BUT OPPOSITE 02. SEE R33865A FOR INLET FLANGE AND OPTIONAL OUTLET FLANGE DIMENSIONS. *03. NOMINAL OUTLET DIAMETER HOUSING A* B C DIMENSIONS (IN.) HA HC HE HG JA Q CA CA CA CA CA CA CA R38848C H Accessories Inlet & Outlet Flange J A I.D. E DIA. D DIA. C B.C. B O.D. (G).44 DIA. HOLES (SEE NOTE ) DIMENSIONS (IN.) A B C D E G H J NOTE: R33865A Holes will not be drilled unless customer specifies. If drilled per std. dims shown, holes will be on centerline unless otherwise specified. Custom hole patterns available at additional charge. 01. Discharge flanges not available on downblast discharge configurations. Slide Gate Damper A + 2" K D C J H OPEn CLOSED B O.D. FLAnGE, FILTER OR GUARD CAn BE MOUnTED OvER THIS O.D. G A I.D. F E NOTE: 01. Slide Damper Gate not available on downblast or bottom angular down discharge positions. DIMENSIONS (IN.) A B C D E DIMENSIONS (IN.) F G H J K R33866 Aerovent Bulletin

14 Dimensional Data Belt Drive Arrangements 1 or 9 CA 14 ALSO AVAILABLE WITH 6 AND 8 INLETS CA 15 AND CA 18 ALSO AVAILABLE WITH 6 AND 10 INLETS ALL MODELS, DISCHARGE FLANGE NOT AVAILABLE FOR DOWN BLAST POSITION. NOTES: 01. CW SHOWN, CCW SIMILAR BUT OPPOSITE 02. SEE R33865 FOR OPTIONAL INLET FLANGE AND OUTLET FLANGE DIMENSIONS. **03. NOMINAL INLET & OUTLET DIMENSIONS 04. ARR.1 LESS MOTOR ARR.9 WITH MOTOR 05. STANDARD MOTOR IS ON RIGHT (AS SHOWN) REGARDLESS OF ROTATION. LEFT SIDE OPTIONAL HOUSING A** B C** DIMENSIONS (IN.) D G H HA HC HE HG CA CA CA CA CA CA CA HOUSING DIMENSIONS (IN.) J K L M P Q SE SD KS FR CA x T CA x T CA x T CA x T CA x T CA x T CA x T R33841D 14 Aerovent Bulletin 916

15 Typical Specifications Type CA/CABD Furnish and install Model CA/CABD Cast Aluminum Pressure Blowers, as manufactured by Aerovent, Minneapolis, Minnesota. Fans shall be of the size and arrangement as indicated in the fan schedule. HOUSINGS All housings shall be heavy duty cast aluminum construction. All units shall be built with an adjustable discharge housing which can be field rotated to any of the eight standard positions. WHEELS The wheel shall be of the radial bladed backplate or backward curved design, and shall be cast aluminum construction. Wheels shall be suitable for exhaust purposes where low volume and high pressure applications exist. BEARINGS Bearings on belt driven units shall be selected to have a minimum average life of 200,000 hours (L-10 minimum life of 40,000 hours) based on AFBMA rating designations. The bearings shall be pillow block type, heavy duty, anti-friction, self-aligning ball bearings. SHAFTS Fan shafts on belt drive units shall be per AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring-gauged for accuracy. Shafts shall be sized so that the first critical speed will be at least 1.40 times the maximum operating speed. MOTORS Fan motors shall be foot-mounted or C-Face NEMA Design B, standard industrial, continuous duty, ball bearing, variable torque type suitable for operation on voltage, phase and hertz, as listed in the fan schedule. Motor bearings shall have a minimum L-10 life, as defined by AFBMA, of at least 40,000 hours (200,000 hours average life). For arrangement 4, size 8-12 blower motors must be C-Face only with feet. For arrangment 4 size 15 & 18 minimum motor frame is 182T. BALANCING Prior to shipment all fans shall be completely assembled and test run as a unit at the operating speed. Final balance of the completed fan assembly shall be taken by electronic equipment. Records of the vibration readings in the axial, vertical, and horizontal planes shall be maintained and a written copy of this record shall be available upon request. SUBMITTALS Submittals for approval of equipment shall include copies of outline drawings and pressure-volume performance curves showing point of operation. ACCESSORIES The fans shall be supplied with the following optional accessories: Slide Gate Damper (Inlet or Outlet) OSHA Belt Guard (Arr. 1 or 9) Drain With Plug OSHA Shaft and Bearing Guard (Arr. 1 or 9) Flanged Inlet (Drilling Optional) Floor Mount Isolators, RIS Flanged Outlet (Drilling Optional) Floor Mount Isolators, Spring Inlet or Outlet Guard Teflon Shaft Seal Inlet Filter Weather Hood (Inlet or Outlet) Inlet Silencer M CE Mark Fan Weights Without Motor ARRANGEMENT Size 8 Size 9 Size 10 Size 12 Size 14 Size 15 Size HI and Motor Weights FRAME T 145T 182T 184T ODP TEFC Aerovent Bulletin

16 Quality Air Handling Equipment AXIAL FLOW Tubeaxial Panel Fan Mancooler Ring Fan Tubeaxial Adjustable Pitch VANEAXIAL Type VT Type W Adjustable Pitch Type VTF Fiberglass Type B Higher Pressure Axico Anti-Stall CENTRIFUGAL Industrial Exhaust CB / CBA Series 14 High Pressure Centaxial Pressure Blower ROOF VENTILATOR Upblast Propeller Upblast Axial Tu-WAY Fiberglass PRV Centrifugal AIR HEATER Gas-Fired Air Make-Up Steam Air Make-Up Door Air Heater WARRANTY Aerovent equipment is guaranteed to deliver its rated output, if properly installed and operated under normal conditions. Aerovent will correct by repair, replacement, or issuance of credit at our option, F.O.B. our plant, defects in material or workmanship which may develop under normal and proper use within eighteen (18) months after date of shipment from our factory, if purchaser gives us notice within ten (10) days of discovering such defects. The correction of these defects by repair, replacement, or issuance of credit shall constitute fulfillment of all obligation to purchaser. (NOTE: We will not assume expense or liability for repairs made outside our factory without prior written consent.) TM QBF11/08

CAST ALUMINUM PRESSURE BLOWERS

CAST ALUMINUM PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CAST ALUMINUM PRESSURE BLOWERS TPD TPB CATALOG 820 JANUARY 2013 PRESSURE BLOWERS Models TPD TPB Twin City Fan & Blower s Cast Aluminum

More information

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB CATALOG 820 January 2013 PressureBlowers Models TPD TPB Twin City Fan & Blower s Cast Aluminum Pressure Blowers are the perfect

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

TU-WAY ROOF VENTILATORS

TU-WAY ROOF VENTILATORS BULLETIN 615 December 2000 TU-WAY ROOF VENTILATORS Tu-WAY Roof Ventilators Aerovent has provided quality air moving and ventilation equipment for over sixty-five years and is a recognized leader in this

More information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S MODEL TCBS CATALOG AX220 MAY 2013 TUBEAXIAL S Model TCBS The Twin City Fan & Blower model TCBS

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW   CATALOG 1260 APRIL 2015 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS PRESSURE BLOWERS MODEL PBW CATALOG 120 APRIL WWW.TCF.COM PRESSURE BLOWERS Overview Model PBW The PBW is designed for low flow and high

More information

BULLETIN S-30. June 1999 SHIP-OUT-OF-STOCK (SOS) Air Moving Equipment

BULLETIN S-30. June 1999 SHIP-OUT-OF-STOCK (SOS) Air Moving Equipment BULLETIN S-30 June 1999 SHIP-OUT-OF-STOCK (SOS) Air Moving Equipment Ship-Out-of-Stock (S.O.S.) Program When you need a quality fan in a hurry, you can depend on Aerovent s S.O.S. Program. Aerovent has

More information

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type T Belt Driven Model TTABD / VTBD The Industrial Choice. Vane Section For Model VTBD Model TTABD TUBEAXIAL & VANEAXIAL S Type "T" Belt Driven Model TTABD / VTBD BULLETIN 424-A November 1998 Model TTABD/VTBD Tubeaxial/Vaneaxial Fans Aerovent

More information

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS Model PBW CATALOG 120 April PRESSURE BLOWERS Overview Model PBW The PBW is designed for low flow and high static pressures, yet stable operation throughout

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

FIXED PITCH PROPELLER FANS

FIXED PITCH PROPELLER FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS FIXED PITCH PROPELLER FANS MODEL TCWP CATALOG AX500 DECEMBER 2012 PROPELLER FANS Model TCWP Fixed Pitch Heavy-Duty Construction Twin

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C BULLETIN 616 July 1997 Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile

More information

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide

More information

& 12" 96" / TABD CATALOG

& 12 96 / TABD CATALOG The Industrial Choice. Model TA Direct Drive Model TABD Belt Driven TUBEAXIAL S Macheta Airfoil Design Direct Drive & Belt Driven Sizes 2" through 96" Models TA / TABD CATALOG 5 August 204 Tubeaxial Fans

More information

Turbo Pressure Blowers

Turbo Pressure Blowers www.americanfan.com Bulletin VP4 Turbo Pressure Blowers Howden Industrial Fan Group American Fan / Joy Fan / Garden City Fan Features Heavy gauge continuously welded housings, reversible and rotatable

More information

Defining Innovation. backward curved FANs

Defining Innovation. backward curved FANs Defining Innovation. high efficiency industrial backward curved FANs TYPE HIB BULLETIN 00-B May 20 HIB High-Efficiency Industrial Backward-Curved Fans Model HIB fans from Twin City Fan & Blower employ

More information

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

PBS SERIES FABRICATED STEEL PRESSURE BLOWERS Snider Road, Mason, OH Telephone:

PBS SERIES FABRICATED STEEL PRESSURE BLOWERS Snider Road, Mason, OH Telephone: O d n a EM ial r t s u Ind g A lin d n a ir H t lis a i c e Sp PBS SERIES FABRICATED STEEL PRESSURE BLOWERS 69 Snider Road, Mason, OH 500-9 Telephone: 51-5-0600 Visit us at www.cincinnatifan.com for more

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications... Industrial Material Handler Page Introduction.......................................... 2 Information.......................................... 3-5 Specifications MH Specifications.....................................

More information

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone: HDBI BLOWERS OEM and Industrial Air Handling Specialist BACKWARD INCLINED CLASS II CLASS III CLASS IV 797 Snider Road, Mason, OH 45040-915 Telephone: 51-57-000 Visit us at www.cincinnatifan.com for more

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS The Industrial Choice. TURBO PRESSURE BLOWERS Models HPBA / HPBS CATALOG 914 February Turbo Pressure Blowers Models HPBA HPBS The HPB series of fans are low volume, high-pressure blowers designed for stable

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX510-A October 2009 ADJUSTABLE PITCH PROPELLER FANS TYPE TCWPX TCWPX Adjustable Pitch Propeller Fans Sizes 24" 48" Direct Drive Belt Driven Heavy-Duty Construction Twin

More information

BULLETIN 912-A. February 1999 HIGH PRESSURE BLOWER. Model HPB Direct Drive/Belt Driven

BULLETIN 912-A. February 1999 HIGH PRESSURE BLOWER. Model HPB Direct Drive/Belt Driven BULLETIN 912-A February 1999 HIGH PRESSURE BLOWER Model HPB Direct Drive/Belt Driven Model HPB High Pressure Blowers Aerovent s High Pressure Blowers feature high static pressure capabilities from 11"

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

UPBLAST AXIAL ROOF VENTILATORS

UPBLAST AXIAL ROOF VENTILATORS BULLETIN 616 July 1997 UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile of Aerovent s upblast roof ventilators.

More information

Turning Air Into Solutions. CAST IRON BLOWERS MODEL CIW

Turning Air Into Solutions. CAST IRON BLOWERS MODEL CIW Turning ir Into Solutions. CST IRON BLOWERS OEL CIW CTLOG 850 ay 2012 CastIronPressureBlowers odel CIW Twin City Fan & Blower s CIW Cast Iron Pressure Blowers are the perfect choice for providing low volume,

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 MARCH, 2014 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

turbo pressure blowers

turbo pressure blowers efining Innovation. turbo pressure blowers TYPE TBNA TBNS BULLETIN May TBN Turbo Pressure Blowers Introduction The TBN series of fans are low volume, high-pressure blowers designed for stable operation

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBA TBR CATALOG 10 APRIL 13 TURBO PRESSURE BLOWERS Models TBA TBR TBR Arrangement 8 Model TBA and TBR fans from

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INUSTRIAL PROCESS AN COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBNA TBNS CATALOG 12 AUGUST 14 TURBO PRESSURE BLOWERS Overview TBNA I TBNS The TBN series of fans are low volume,

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 SEPTEMBER, 2011 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200 Defining Innovation. turbo pressure blowers MODEL TBA TBR 1 Twin City Catalog CATALOG -A May 11 Model TBA/TBR Turbo Pressure Blowers Model TBA and TBR fans from Twin City Fan & Blower are constant pressure,

More information

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio Vaneaxial Fans Series 25 Series 53 Series 53C Series 54 Series 55 BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 45356 February 2008 Index Model Code Explanation...Page

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE FCV (Forward Curved) Ventilating

More information

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Turning Air Into Solutions. PLUG FANS TYPE BCPL Turning Air Into Solutions. PLUG FANS TYPE BCPL CATALOG 350 December 2009 BCPL Plug Fans BCPL plug fans from Twin City Fan & Blower are compact and versatile. Their versatility allows them to be used for

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009 Defining Innovation. radial tip FANS TYPE HRT BULLETIN 980 October 2009 HRT Radial Tip Fans Twin City Fan & Blower s Type HRT Industrial Duty Radial Tip Fan line is engineered for higher specific speeds.

More information

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted The Industrial Choice. Model FSWB Wall Mounted Model FSR Roof Mounted FILTERED AIR SUPPLY FANS Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF CATALOG 664 June 2013 Filtered Air Supply Fans Roof

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF   CATALOG 950 AUGUST 2012 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012 RADIAL TIP FANS Model RTF Model RTF radial tip fans are of a heavy duty, rugged design,

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS BULLETIN 420 November 2000 MARINE DUTY TUBEAXIAL & VANEAXIAL FANS Type MD Direct Drive Model MDTM, MDVM & MDVH Marine Duty Tubeaxial and Vaneaxial Fans Aerovent s Marine Duty Fans feature medium and high

More information

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS New Energy Saving Wheel Mounted Motors to 125 HP Pre-Engineered Sizes to 60" Capacities to 156,000 CFM CHICAGO BLOWER CORPORATION GLENDALE

More information

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tube Axial Fan Page Specifications & Dimension Data Performance Data Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS CATALOGUE M1250 April 2015 TURBO PRESSURE BLOWERS Overview TBNA I TBNS The TBN series of fans are low volume, high-pressure blowers designed

More information

BACKWARD INCLINED BI AND BIA INDUSTRIAL SWSI CENTRIFUGAL FANS

BACKWARD INCLINED BI AND BIA INDUSTRIAL SWSI CENTRIFUGAL FANS BLLEIN 71-D November 2004 BACKWARD INCLINED BI AND BIA INDSRIAL SWSI CENRIFGAL FANS BI Flat Blade Design BIA Airfoil Blade Design Class I, II, III, IV BI & BIA Industrial Centrifugal Fans Aerovent s BI

More information

PEERLESS ELECTRIC INDUSTRIAL FANS

PEERLESS ELECTRIC INDUSTRIAL FANS PEERLESS ELECTRIC INDUSTRIAL FANS HIGH QUALITY HIGH EFFICIENCY VERSATILITY TYPICAL INDUSTRIES PEERLESS ELECTRIC HAS SERVED FOR MORE THAN 95 YEARS HVAC Paint Chemical Clothing Leather Steel Aviation Plastic

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

HIGH VELOCITY FUME EXHAUST FANS

HIGH VELOCITY FUME EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS HIGH VELOCITY FUME EXHAUST S TFE QFE CATALOG 1500 MAY 2012 FUME EXHAUST S Models TFE & QFE Inline Fume Exhaust Fans Twin City Fan & Blower

More information

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX100-A October 2008 AXIFAN VANEAXIAL FANS TYPE TCVA TCVA Vaneaxial Fans The heart of the TCVA AXIFAN fan lies in its wheel. Cast of high strength aluminum alloy, the one-piece

More information

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 model vp - belt drive utility set Application VENT-PAK fan wheels are the versatile, quiet, energy efficiency backward inclined

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

Type VA Vanax Fans. Models VA, VAD, & VAB

Type VA Vanax Fans. Models VA, VAD, & VAB Type VA Vanax Fans Models VA, VAD, & VAB Type VA Direct Drive Model VA Sizes 6 through 10 207 to 1,811 CFM Static Pressure to 1-1/2 Type VAB Belt Drive Model VAB Sizes 12 through 48 1,004 to 47,176 CFM

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

TYPE HP. Static pressures to 128 WG Capacities to 20,000 CFM Temperatures to 600 F. PRESSURE BLOWERS Static pressures to 58 WG Capacities to 5,200 CFM

TYPE HP. Static pressures to 128 WG Capacities to 20,000 CFM Temperatures to 600 F. PRESSURE BLOWERS Static pressures to 58 WG Capacities to 5,200 CFM BULLETIN 1 JANUARY, 20 TYPE HP PRESSURE BLOWERS PRESSURE BLOWERS Static pressures to 5 WG Capacities to 5,200 CFM Static pressures to WG Capacities to 20,000 CFM Temperatures to 00 F. THE NEW YORK BLOWER

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

SERIES CAST ALUMINUM PRESSURE BLOWERS

SERIES CAST ALUMINUM PRESSURE BLOWERS OEM and Industrial Air Handling Specialist PB SERIES CAST ALUMINUM PRESSURE BLOWERS 7697 Snider Road, Mason, OH 500-95 Telephone: 5-57-0600 Visit us at www.cincinnatifan.com for more information. Cat.

More information

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone:

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone: OEM and Industrial Air Handling Specialist SERIES CPAF CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

Low Silhouette Power Roof Ventilator Propeller

Low Silhouette Power Roof Ventilator Propeller LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements SURGE LIMITING BULLETIN 485 APRIL, 2017 PB FANS Designed for high pressure, low flow applications with stringent job process requirements Capacities to 30,000 CFM Static pressures to 180 WG Temperatures

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

SERIES CAST ALUMINUM PRESSURE BLOWERS

SERIES CAST ALUMINUM PRESSURE BLOWERS d an M E O ial r t s u Ind g A lin d n a ir H t lis a i c e Sp PB SERIES CAST ALUMINUM PRESSURE BLOWERS 7697 Snider Road, Mason, OH 500-95 Telephone: 5-57-0600 Visit us at www.cincinnatifan.com for more

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 52,000 CFM in static pressure applications up to 3/4 w.g. Motor and drives are located outside of the exhaust

More information

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 370 January 2007 AIRFOIL FANS TYPE BAE SWSI and DWDI BAE SWSI and DWDI Airfoil Fans Featuring the E-Series Wheel This catalog features the new BAE airfoil wheel design.

More information

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN TURNING AIR INTO SOLUTIONS. COMPACT PLENUM S ECLFN ECLQN CATALOG 456 July 2017 PLENUM S Overview ECLFN I ECLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated or factory-built

More information

AXIFAN VANEAXIAL FANS

AXIFAN VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXIFAN VANEAXIAL FANS MODEL TCVA CATALOG AX100 JUNE 2013 VANEAXIAL FANS Model TCVA The heart of the TCVA AXIFAN fan lies in its wheel.

More information

Industrial Mini Vent Sets

Industrial Mini Vent Sets Industrial Mini Vent Sets FRP Construction M I N I S E R I E S and Impellers Volume Range shut off up to 4000 (1888 l/sec) Static pressures up to 19 W.G. (4719 Pa) Industrial and Commercial Applications

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

FILTERED AIR SUPPLY FANS

FILTERED AIR SUPPLY FANS BULLETIN 664-B September 2004 FILTERED AIR SUPPLY FANS Wall Mounted Roof Mounted Catalog Numbering System To identify a specific fan for ordering or engineering specification, it is necessary to show

More information

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011 Defining Innovation. high efficiency INDUSTRIAL airfoil FAN TYPE HAF BULLETIN 1150 May 2011 HAF High Efficiency Industrial Airfoil Fans Model HAF fans from Twin City Fan & Blower employ a high efficiency

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS BULLETIN 0 January 007 SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS TYPE ACX / ACXD TYPE ATD / ATDR / ATDW / ATDWR TYPE ATB / ATBR / AWX / AWXR Model ACX Model ATB Model ACXD Model ATDR Model AWX Centrifugal

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index AIR HANDLING-RADIAL BLADE CENTRIFUGAL FAN XB GENERAL The centrifugal fan shall be designed and manufactured by Sheldons Engineering to ensure

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information