STAINLESS STEEL CONDENSING GENERATOR RANGE RATED. MODEL Heat thermal input 65,5. 62,0 Heat output (80 C/60 C) 14,0

Size: px
Start display at page:

Download "STAINLESS STEEL CONDENSING GENERATOR RANGE RATED. MODEL Heat thermal input 65,5. 62,0 Heat output (80 C/60 C) 14,0"

Transcription

1 QUADRIFOGLIO B STAINLESS STEEL CONDENSING GENERATOR > PRODUCT PLUSES: - Steel vertical module with low thermal load, huge water content - The exchanger in stainless steel AISI 31 Ti consists in a tubes bundle. The helical rolling section is patented and has been designed to enhance thermal exchange and fumes condensation. - Premixed microflame burner, Low NOx combustion, vertical layout The reduced vertical clearance enables water/flue gas exchange throughout the entire surface of the exchanger. Quick opening system of combustion chamber door (right/left reversible) for inspection and maintenance operations. - Control board with button for regulation and setting of parameters, wide interface display and ON/ OFF switch - Pocket on boiler flow, for the eventual installation of a safety valve - Equipped with temperature probes on flow and return and water minimum pressure switch - Flue gas outlet reversible on right or left side of the generator - Flue gas no-return system for modular installation. As a standard on each boiler. - Wide and complete offer of water, gas and flues accessories - necessary for the installation of cascades including 2 or 3 generators > PRODUCT ADVANTAGES: - Very high efficiency: can exceed 109 in some operating conditions - Wide output range of Quadrifoglio s offer: from 70 to 90 (cascade of 3 modules of 320 each) - The huge water volume inside the generator enables connection to the heating system without adding separation devices, permitting design of systems with a very high ΔT - Double system return, thus managing systems operating with different temperature, albeit granting the best possible layering inside the boiler body - Smallest polluting emissions (class 5 NOx) - Combustion control through microprocessor, reaching then modulation of the single generator until 20 of the maximum capacity - Quadrifoglio electronics handles modular installations, domestic hot water production via a storage tank and system pump with outside temperature compensation on flow water temperature PROTECTED REMOTE MODULAR CLASS 5 CLIMATIC RANGE RATED NOX MODEL Heat thermal input 5,5 11,0 207,0 299,0 14,0 23,0 41,0 2,0 Heat output (80 C/0 C) Heat output (50 C/30 C) Efficiency (80 C/0 C) Efficiency (50 C/30 C) P P P P Efficiency 30 reduced load 109, 109, 109, 109, Energy marking (92/42 EEC) NOx emission class Water content liters Operating pressure bar bar Empty weight Kg Protection rating IP X0D X0D X0D X0D CODE 0RB010WA 0RB110WA 0RB410WA 0RB10WA 4,4 13,7 9,9 15,0 98,3 114,0 22,5 125,0 24,8 98,3 204,0 40,2 220,0 44,2 98,5 294,5 320,0,8 98,5 Gennaio 2014

2 > DIMENSIONS > WATER, GAS AND FLUES CONNECTIONS DIAMETER MODELLO System flow 1' 1/4 1' 1/4 2' DN 5 2 Low temperature system return 1' 1/4 1' 1/4 2' DN 5 3 Gas inlet 1' 1' 1' 1' 4 High temperature system return 1' 1/4 1' 1/4 2' DN 5 F Flues stack Ø (mm) > DIMENSIONS AND SIZES ITEM L H P A B C D E G I unit size mm mm mm mm mm mm mm mm mm mm QUADRIFOGLIO B QUADRIFOGLIO B QUADRIFOGLIO B QUADRIFOGLIO B > ACCESSORIES FOR INDIVIDUAL OR MODULAR INSTALLATION DESCRIPTION CODE - DESCRIPTION CODE - Kit for handling (via a not-supplied thermostat) of a DHW storage X0 M-F reduction nipple 2' - 1'1/ X0 Additional probe for a tank and or system flow for modular installation, with/without water separator 2 mt cable 5 mt cable 1KWMA11W X0 Flange - connection Terminal for flues manifold DN50-1'1/ X0 DN5-2' 0420X0 10 mm 0410X0 200 mm 04108X0 300 mm X0 Motorized valve, DN 50, 230 V - 50 Hz, for model 70 and X0 Flues manifold 10 mm 04107X0 200 mm 04109X0 300 mm X0 Motorized valve, DN 50, 230 V - 50 Hz, for model 220 and X0 M/F flue gas pipe, PPs, 0,5 mt length 100 mm X0 10 mm X0 200 mm 04107X0 100 mm X0 Outdoor probe X0 M/F flue gas pipe, PPs, 1 mt length 10 mm X0 200 mm 04102X0 300 mm 04103X0 Gas manifold Water manifold 1' 1/ X0 2' X0 2 1/ X0 2' X0 2' 1/ X0 4' X0 90 M/F bend, PPs 100mm X0 10 mm X0 200 mm 04100X0 300 mm 04101X0 Flange kit (including nuts, bolts and gaskets) F-F coupling 2' X0 2' 1/ X0 4' 04201X0 1' 1/ X0 2' 04203X0 M/F reduction, PPs mm X mm X mm X0 Gennaio

3 > MODULAR INSTALLATIONS WITH ACCESSORIES MATCHING AVAILABILITY HEAT INPUT HEAT OUTPUT CASCADE MODULATION Pmin/Pmax MODELS COMBINATION MODULES QTY 80/0 C 50/30 C 50/30 C ,0 128,8 139,8 15,0/139, ,5 178,4 194,9 15,0/194, ,0 228,0 250,0 24,8/250, ,0 242,8 24,8 15,0/24, ,5 292,4 319,9 15,0/319, ,0 318,0 345,0 24,8/345, ,0 342,0 375,0 24,8/375, ,0 408,0 440,0 44,2/440, ,0 432,0 470,0 24,8/470, ,0 498,5 540,0 44,2/540, ,0 522,0 55,0 24,8/55, ,0 40,0,8/40, ,0 12,0 0,0 44,2/0, ,0 702,5 70,0 44,2/70, ,0 793,0 80,0 44,2/80, ,0 883,5 90,0,8/90, Remark: for the other model combinations the Company doesn t supply cascade accessories > ACCESSORIES MATCHING WATER AND GAS FLUES MANIFOLD LOWER BACK OUTLET FLUES MANIFOLD MID BACK OUTLET FLUES MANIFOLD TOP OUTLET WATER AND GAS MANIFOLDS DESCRIPTION OF CASCADE ACCESSORIES A Adaptor for connection of motorized valve B Adaptor connections boiler/manifold C 90 bend, PPs, with gaskets E Flues manifold, PPs, including gaskets F Flange for manifold (one blind flange, a drilled one, including gaskets, screws, nuts) G Gas manifold, including ON/OFF valve, flexible hose, gaskets, screws, nuts I P R S T V Water manifold, including gaskets, screws, nuts One side-blind flues manifold, including condensate siphon Reduction for connection top flues manifold/vertical flue pipe Manifold for lodging of additional optional safety devices (according to Italian INAIL rules) Vertical pipe for connection from stack to top flues manifold Motorised ON/OFF valve 8 Gennaio 2014

4 > ACCESSORIES MATCHING FOR CASCADING INSTALLATION OF 2-3 MODULES G G G I I I S S S F F F B B A A A V V 1 ½ gas manifold 2 gas manifold 2 1/2 gas manifold 2 water manifold 2 ½ water manifold 4 water manifold 2 safety accessories manifold 2 ½ safety accessories manifold 4 safety accessories manifold 2 flange kit 2 ½ flange kit 4 flange kit 1 ¼ F-F coupling 2 F-F coupling 2 1 ½ M-F reduction nipples DN 50 flange - 1 ¼ connection DN 5 flange - 2 connection DN 50 valve DN 5 valve HEAT INPUT QTY MODULES MANI- FOLD X X X X X X X X X X X X X X X X0 0420X X X nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr , , , , , , , , , , , , , , , Flow Return Flow Return Return Flow Return Flow Return Flow Return Flow Return Flow Return Flow Return Flow Return Flow Return Flow Return Gennaio

5 > ACCESSORIES MATCHING FOR CASCADING INSTALLATION OF 2-3 MODULES P P P E E E T T T T T T T C C C C R R R Ø 300 flue manifold (first boiler) Ø 200 flue manifold (first boiler) Ø 10 flue manifold (first boiler) Ø 300 flue manifold (additional boiler) Ø 200 flue manifold (additional boiler) Ø 10 flue manifold (additional boiler) 1 mt MF pipe, Ø 300, PPs 1 mt MF pipe, Ø 200, PPs 0,5 mt MF pipe, Ø 200, PPs 1 mt MF pipe, Ø 10, PPs 0,5 mt MF pipe, Ø 10, PPs 1 mt MF pipe, Ø 100, PPs 0,5 mt MF pipe, Ø 100, PPs 90 MF bend, Ø MF bend, Ø 200, PPs 90 MF bend, Ø 10, PPs 90 MF bend, Ø 100, PPs Ø MF reduction, PPs Ø MF reduction, PPs Ø MF reduction, PPs HEAT INPUT QTY MODULES FLUE GAS EVACUATION X X0 0410X X X X X X X X X X X X X X X X X X nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr. nr , , , , , , , , , , , , , , , Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Low Mid Top Gennaio 2014

6 Gennaio

VICTRIX PRO Wall-hung modular condensing boiler for heating only

VICTRIX PRO Wall-hung modular condensing boiler for heating only PRO Wall-hung modular condensing boiler for heating only Wide range (5 models) High efficiency and low pollutant emissions thanks to condensing technology Modulating heat output from 10 to 100% Possible

More information

available in battery up to 4 units for a total of 560 kw

available in battery up to 4 units for a total of 560 kw MODULATING CONDENSING BOILER with double premix low NOx burner and double heat exchanger EXPANDABLE IN BATTERY for indoor and outdoor installations (IPX5D) OUTPUT RANGE from 10 to 560 kw (in battery) WORKING

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0

More information

Hamilton 3VO Submittal

Hamilton 3VO Submittal Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum

More information

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-04EN - Edition 04-01/04/2008 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53 Installation, use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 374957 G5BF 49T57 3748953 G5BF 489T53 9036 (6) TECHNICAL FEATURES TYPE - Boiler

More information

Crest Heating Boilers FBN(L)

Crest Heating Boilers FBN(L) Replacement Parts List S & SERVICE DEMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 2500-6000 69 67 59 62 79 18 26 66 76

More information

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Replacement Parts List

Replacement Parts List 100275093_2000534000_Rev H Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Noble Boiler & Combi NKB 080-150

More information

Crest Heating Boilers FBN(L)

Crest Heating Boilers FBN(L) Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65

More information

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

PRESSURIZED STEEL BOILER WITH REVERSED FLAME smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-06EN - Edition 06-01/12/2010 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

Power HT kw. Outputs from 115 to 320 kw

Power HT kw. Outputs from 115 to 320 kw Power T -0 kw luminium-silicon exchanger with glass wool insulation: high efficiency and reliability and long life Low emissions pre-mixing burner Digital control panel with back-lighted LCD display and

More information

Oil - kerosene burner

Oil - kerosene burner Installation, use and maintenance instructions Oil - kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 9038 () TECHNICAL FEATURES Thermal power output 8 0 kw.3 5 kg/h Fuel Gas oil 35s,

More information

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve NEOTHERM Hydronic Boiler NTH Hydronic Boiler Date: Indoor Sizes 285-850 Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Large LCD display

More information

VERY LOW TEMPERATURE, CONDENSING, PRESSURIZED BOILER. From 69 kw Output (67 kw Input) to 1550 kw Output (1520 kw Input)

VERY LOW TEMPERATURE, CONDENSING, PRESSURIZED BOILER. From 69 kw Output (67 kw Input) to 1550 kw Output (1520 kw Input) (oil/gas) RY LOW TEPERATURE, CONDENSIN, PRESSURIZED BOILER OUTPUT RANE From 69 kw Output (67 kw Input) to 1550 kw Output (1520 kw Input) OPERATION TEPERATURE no limit on the return temperature SUPPLY ODELS

More information

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN Linea 28 Mark 1 Serial Number up to 164370001 Outer Casing 1 RIVET 5093 5 LABEL 1781 2 LOCATING CLIP R/H 1881 6 CASE 1922 3 CLIP 5230 7 LOCATING CLIP L/H 1882 4 SELF ADHESIVE ALUM SHEET 5333 1 Main Frame

More information

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.

More information

Controls and Accessories Part Number Controls and Accessories Part Number

Controls and Accessories Part Number Controls and Accessories Part Number Linea 24 Mark 1 Serial Number Up to 161380001 Controls and Accessories Part Number Controls and Accessories Part Number CLOCK - MECHANICAL 201 CLOCK - DIGITAL 202 CONVERSION KIT LPG - NG 01005225 CONVERSION

More information

8 Parts To Your Door Repair Parts Trade Price List (R-17) Effective June 1, 2017

8 Parts To Your Door Repair Parts Trade Price List (R-17) Effective June 1, 2017 Peerless PURE 1 29 41 0 26 42 4 9 8 1 10 9 44 1 27 28 2 22 8 5 41 40 4 14 5 6 15 4 7 2 6 7 1 2 17 21 19 25 24 11 8 Parts To Your Door Repair Parts Trade Price List (R-17) Effective June 1, 17 Description

More information

ECONOMATIC STEEL SHELL BOILERS

ECONOMATIC STEEL SHELL BOILERS ECONOMATIC STEEL SHELL BERS ECONOMATIC SERIES Since 1985 Stokvis has been supplying high quality products to the heating industry. The Economatic boilers are no exception.they are 3 pass reverse fl ame,

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent

More information

Spare parts list SI RSF 22/04/

Spare parts list SI RSF 22/04/ Spare parts list 6720620020 25SI RSF 22/04/2009 6720620020 1 22/04/2009 6720620020 2 22/04/2009 6720620020 3 Spare parts list 1 Pump / Hydraulic assy 22/04/2009 6720620020 4 Pos description S-Nr ordering

More information

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw. The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards

More information

CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER. Model UCS-240 PARTS, KITS & OPTIONAL ACCESSORIES

CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER. Model UCS-240 PARTS, KITS & OPTIONAL ACCESSORIES CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER Model UCS-240 PARTS, KITS & OPTIONAL ACCESSORIES ORDERING INSTRUCTIONS ORDER PARTS THROUGH YOUR NEAREST SUPPLIER. WHEN ORDERING PARTS, OBTAIN MODEL NUMBER

More information

XIII. Repair Parts 106

XIII. Repair Parts 106 XIII. Repair Parts All Alpine Repair Parts may be obtained through your local authorized U.S. Boiler Company representatives or outlets. Should you require assistance in locating a U.S. Boiler Company

More information

CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER. Model DMG-240 PARTS, KITS & OPTIONAL ACCESSORIES

CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER. Model DMG-240 PARTS, KITS & OPTIONAL ACCESSORIES CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER Model DMG-240 PARTS, KITS & OPTIONAL ACCESSORIES ORDERING INSTRUCTIONS ORDER PARTS THROUGH YOUR NEAREST SUPPLIER. WHEN ORDERING PARTS, OBTAIN MODEL NUMBER

More information

Spare parts list CDI RSF 22/04/

Spare parts list CDI RSF 22/04/ Spare parts list 6720620013 26CI RSF 22/04/2009 6720620013 1 22/04/2009 6720620013 2 22/04/2009 6720620013 3 Spare parts list 1 Pump / Hydraulic assy 22/04/2009 6720620013 4 Pos description S-Nr ordering

More information

RS/M SERIES. Modulating Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES The PRESS G series of burners covers a firing range from 107 to 1660 kw and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups

More information

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.

More information

Power Direct Vent PDV T Model

Power Direct Vent PDV T Model REPLACEMENT PARTS LIST Power Direct Vent PDV T Model Includes Hydrojet Sediment Reduction System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT

More information

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS The Riello 40 FS series of one stage gas burners, is a complete range of products developed to respond to any request for light industrial application. The Riello 40 FS series is available in five different

More information

ONE STAGE GAS BURNERS RDBS SERIES

ONE STAGE GAS BURNERS RDBS SERIES ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high

More information

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =

More information

SPARE PARTS LIST - July

SPARE PARTS LIST - July Versions for CANADA SPARE PARTS LIST - July 2005 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is

More information

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw. The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding

More information

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency M K MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency Gas/ gas oil working Output from 44 to 291,7 (from 37.840 to 250.862 of water efficiency). Pipe

More information

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw The Riello 40 GS series of one stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 40 GS series is available in four different models, with

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

Spare parts list GREENSTAR CAMRAY. Burner 24/04/

Spare parts list GREENSTAR CAMRAY. Burner 24/04/ Spare parts list 620620260 GREENSTAR CAMRAY 3 1 8 6 2 9 Burner 24/04/2009 620620260 1 24/04/2009 620620260 2 24/04/2009 620620260 3 Spare parts list 1 Cabinet Assembly rawing Heatslave 12/14 24/04/2009

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options

More information

Eco Home SPARE PARTS CATALOGUE. - October

Eco Home SPARE PARTS CATALOGUE. - October Eco Home SPARE PARTS CATALOGUE - October 2016 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 3747455 G0KI 474T5 90403 (4) - 0/008 TECHNICAL DATA Thermal power output 95 3 kw 8 8 kg/h

More information

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46

More information

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed

More information

Innovo Condensing high efficiency water heater

Innovo Condensing high efficiency water heater Condensing high efficiency water heater IR 12-160/20-160/12-200/20-200/24-245/32-245/ 24-285/32-285/32-380 A Fully room-sealed condensing high efficiency water heater Automatic gas/air premix burning system

More information

JANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS

JANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS JANDY HEATERS Heaters H-58 A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS E-Z FIND CHART MARK V XE XE SERIES I SERIES I MILLIVOLT MILLIVOLT ELECTRONIC MILLIVOLT ELECTRONIC DM, DR EG ES, EC EPG EPS,

More information

Kerosene - oil burner

Kerosene - oil burner Installation, use and maintenance instructions Kerosene - oil burner Two stage operation CODE MODEL TYPE 3746686 G0D 76T8 90 (0) TECHNICAL FEATURES Thermal power output 44 / 54 0 kw 3.7 / 4.5 0 kg/h Fuel

More information

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change Peerless PURE 16 Parts To Your Door Repair Parts List (R-17) Effective June 1, 2017 Description Peerless PURE Heat Exchanger PF-850, for Reference Only 1 5651 $19,468 1 Heat Exchanger PF-1 000, for Reference

More information

Eco5 Compact + SPARE PARTS CATALOGUE. - June

Eco5 Compact + SPARE PARTS CATALOGUE. - June Eco5 Compact + SPARE PARTS CATALOGUE - June 2016 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is

More information

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available

More information

Roue Vortex. Turbina Vortex

Roue Vortex. Turbina Vortex Roue Vortex Turbina Vortex M Series Technical features. Fully submersible pressure tight electric motor Insulation class H. Protection degree IP Speed: 0 rpm. Voltage: three-phase x0/v-0 Hz. Different

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model UNO. R EN - Edition 01-15/10/2007

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model UNO. R EN - Edition 01-15/10/2007 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216080-01EN - Edition 01-15/10/2007 537255 24 MFFI (RO) MET...... 537256 24 MFFI (RO) GPL...... 537632 24 MFFI MET (PL, CZ, UCR)...... 537633 24 MFFI

More information

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F TECHNICAL MANUAL REX/REX F/REX K/REX K F REX DUAL/REX DUAL F PRESSURISED STEEL BOILERS INDEX 1 GENERAL WARNINGS... 4 2 TECHNICAL SPECIFICATIONS... 5 2.1 REX/REX K/REX F/REX K F 7-130 BOILER... 5 2.2 REX/REX

More information

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev E

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev E Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46

More information

DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG

DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG Page: 2 of 10 Report No. R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants

More information

ECONOMATIC REX/REXF REX/REXF DUAL STR

ECONOMATIC REX/REXF REX/REXF DUAL STR TECHNICAL MANUAL ECONOMATIC REX/REXF REX/REXF DUAL STR PRESSURISED STEEL BOILERS 96R WALTON ROAD, EAST MOLESEY, SURREY, KT8 0DL Tel. 08707 707 747 Fax. 08707 707 767 info@stokvisboilers.com - www.stokvisboilers.com

More information

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5 Spare parts catalogue 0020067960.02 GB 07/2008 Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5 Content General view of sheet VU 466/4-5 Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing parts

More information

Boiler Management Unit (BMU)

Boiler Management Unit (BMU) 7 495 Boiler Management Unit (BMU) LMU74... LMU75... LMU7 are digital Boiler Management Units (BMUs) for use in gas-fired appliances equipped with premixing burners. LMU74 without combustion optimization

More information

VIESMANN VITORONDENS 200-T Oil Unit condensing boilers 20.2 to kw

VIESMANN VITORONDENS 200-T Oil Unit condensing boilers 20.2 to kw VISMANN VITORONDNS 200-T Oil Unit condensing boilers 20.2 to 107. kw Datasheet Part no. and prices: see pricelist VITORONDNS 200-T Type BR2A 20.2 to 5.7 kw Cast iron low temperature oil boiler with condensing

More information

FLUE PIPE ACCESSORIES FOR STANDARD AND CONDENSING GAS BOILERS

FLUE PIPE ACCESSORIES FOR STANDARD AND CONDENSING GAS BOILERS FLUE PIPE ACCESSORIES FOR STANDARD AND CONDENSING GAS BOILERS EASE OF INSTALLATION - UNRIVALED FLEXIBILITY INDEX.0 GENERAL. Flue terminal positions. Installation types.3 Method of calculating the maximum

More information

TECHNICAL INFORMATION BIOMASS SOLUTIONS FOR A MORE ECOLOGICAL AND ECONOMICAL WORLD

TECHNICAL INFORMATION BIOMASS SOLUTIONS FOR A MORE ECOLOGICAL AND ECONOMICAL WORLD TECHNICAL INFORMATION BIOMASS SOLUTIONS FOR A MORE ECOLOGICAL AND ECONOMICAL WORLD TECHNICAL INFORMATION Easy handling by microprocessor-control! Logically organized menus makes for easy operation of the

More information

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three

More information

STAR SPARE PARTS LIST

STAR SPARE PARTS LIST STAR SPARE PARTS LIST - January 2005 - WESTEN HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the

More information

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES TWO STAGE LIGHT OIL BURNERS PRESS G SERIES 7/178 356 kw PRESS 1G 13/19 534 kw PRESS 2G 214/356 712 kw PRESS 3G 273/534 1168 kw PRESS 4G 415/83 166 kw The PRESS G series of burners covers a firing range

More information

Figure 1-1(d) Tft Installation Kit

Figure 1-1(d) Tft Installation Kit TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending

More information

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL Low NOx One Stage Light Oil Burners RES G MRBLU SERIES LOW NOx LIGHT OIL RES (Riello Environment Solution) is the new Low NOx light oil burners series with extremely low emissions to meet the increasingly

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

SPARE PARTS CATALOGUE. - September

SPARE PARTS CATALOGUE. - September SPARE PARTS CATALOGUE - September 2014 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning

More information

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod UNIT 1 From Serial Number: 30200001 Untill Serial Number: 31200284 1 ILLUSTRATED PARTS BREAKDOWN Edizione 2010 Rev. A 2 11 10 9 7 3 12 14 30 8 6 5 4 13 15 17 16 18 19 20 28 21 22 27 29 25 24 23 26 Cod.

More information

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 ARE YOU A SHIPOWNER OPERATING IN EMISSIONS CONTROL AREAS ECAs? IS INCREASING SHIP EFFICIENCY YOUR TARGET? ARE FUEL SAVINGS STILL AN

More information

HP5. Heated Probe. Main characteristics. Heated Probe for Micropollutants sampling

HP5. Heated Probe. Main characteristics. Heated Probe for Micropollutants sampling Heated Probe HP5 Heated Probe HP5 Main characteristics Heated sampling probe for the determination of particulate matter and chemicals in the gas phase. It s unique design, combined with the clamps-free

More information

Raptor 085HB-270HB & 155CB Submittal

Raptor 085HB-270HB & 155CB Submittal Raptor 085HB-270HB & 155CB Submittal Residential High Efficiency Gas s RPTR085HB, 110HB, 155HB, 205HB, 270HB, 155CB RPTR Wall Mount and Floor Standing Heating s Wholesaler Job Name Mechanical Contractor

More information

Giotto and Cellini Evoluzione machine range

Giotto and Cellini Evoluzione machine range Giotto and Cellini Evoluzione machine range A- GIOTTO EVOLUZIONE Bodywork Page 2 of 17 ed. 2011/04 A- GIOTTO EVOLUZIONE Bodywork Pos. Code Nr. Description 1 C000004248 Chassis 2 A019904282 Foot 40mm 3

More information

DUO-TEC COMPACT + SPARE PARTS CATALOGUE

DUO-TEC COMPACT + SPARE PARTS CATALOGUE DUO-TEC COMPACT + SPARE PARTS CATALOGUE - July 2015 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this

More information

COMMERCIAL and POOL MODELS: 302C THROUGH 902C

COMMERCIAL and POOL MODELS: 302C THROUGH 902C COMMERCIAL and POOL MODELS: 302C THROUGH 902C CATALOG NO. 9300.753 Effective: 12-01-17 Replaces: 12-01-16 RAYPAK REPLACEMENT PARTS MODEL SIZES: 302C, 402C, 502C, 652C, 752C & 902C MODEL TYPES: HI DELTA

More information

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw TWO STAGE GAS BURNER GULLIVER RSD SERIES 160/208 345 kw The Riello Gulliver is a new model of the series of two stage gas burners, characterized for its small dimensions in spite of its high combustion

More information

Replacement Parts List

Replacement Parts List Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin II Boilers Water Heaters CH CF 992-2072 50 17

More information

Low BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400

Low BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400 COMMERCIAL GAS REPLACEMENT PARTS LIST Low BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400 Effective: March, 2007 ECO 7206 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING

More information

Spare parts list (2015/02) Gö ZSB C ZWB30-4C

Spare parts list (2015/02) Gö ZSB C ZWB30-4C Spare parts list 6720808925 (2015/02) Gö 25.02.2015 1 6720808925 25.02.2015 2 6720808925 25.02.2015 3 6720808925 Spare parts list 1 Sheet metal 25.02.2015 4 6720808925 Pos Description Ordering no. Gas

More information

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 330 to 500 kw Heating capacity: 340 to 500 kw Cooling

More information

SILOXA frame-mounted gas drying system, GK model, set up for outdoor installation

SILOXA frame-mounted gas drying system, GK model, set up for outdoor installation Technical Datasheet 1/5 Condensate trap Moulded piece, material No. 1.4571, for fl ange-mounting on gas cooler DN 150-400 Demister, material No. 1.4571 Condensate outlet via liquid shut-off valve Monitoring

More information

Horizontal And Vertical Centrifugal Pumps

Horizontal And Vertical Centrifugal Pumps Horizontal And Vertical Centrifugal Pumps Lip Bellow Type JP-840 Series Horizontal Centrifugal Pumps are driven by a direct-coupled motor (maximum 3,000 rpm). They are especially suitable for the rapid

More information

DUO-TEC COMPACT + SPARE PARTS CATALOGUE

DUO-TEC COMPACT + SPARE PARTS CATALOGUE DUO-TEC COMPACT + SPARE PARTS CATALOGUE - April 2016 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this

More information

Raptor 085HB-270HB & 155CB Submittal

Raptor 085HB-270HB & 155CB Submittal Raptor 085HB-270HB & 155CB Submittal Residential High Efficiency Gas s RPTR085HB, 110HB, 155HB, 205HB, 270HB, 155CB RPTR Wall Mount and Floor Standing Heating s Wholesaler Job Name Mechanical Contractor

More information

Aqualift F XL Lifting Stations

Aqualift F XL Lifting Stations Aqualift F XL Lifting Stations For industrial / high volume wastewater disposal Leading in Drainage Product Information Applications For use with wastewater from commercial, public and private sources

More information

Energysaver 559FT. Rinnai New Zealand Limited Page 1 of 6 Rinnai Energysaver 559FT Spare Parts: 01-11

Energysaver 559FT. Rinnai New Zealand Limited Page 1 of 6 Rinnai Energysaver 559FT Spare Parts: 01-11 039 017 028 012 019 037 020 018 038 026 701 013 038 027 804 012 Top panel 1 5485 013 Control panel assembly 1 5486 016 Side panel RH 1 5488 017 Side panel LH 1 5489 018 Air filter assembly 1 3026 019 Front

More information

DUO-TEC COMPACT SPARE PARTS CATALOGUE

DUO-TEC COMPACT SPARE PARTS CATALOGUE DUO-TEC COMPACT SPARE PARTS CATALOGUE - Aprile 2016 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this

More information

TWO STAGE PROGRESSIVE GAS BURNERS

TWO STAGE PROGRESSIVE GAS BURNERS TWO STAGE PROGRESSIVE GAS BURNERS RS SERIES RS 28 81/163 325 RS 34 MZ 7/125 39 RS 38 15/232 44 RS 44 MZ 1/2 55 RS 5 116/29 58 RS 64 MZ 15/4 85 RS 7 192/465 814 RS 1 232/698 1163 RS 13 372/93 1512 RS 19

More information

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO GS/M SERIES GS /M / 5 3/8 19 The Riello GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed

More information

Spare parts list CDI RSF 22/04/

Spare parts list CDI RSF 22/04/ Spare parts list 6720620014 24CI RSF 22/04/2009 6720620014 1 22/04/2009 6720620014 2 22/04/2009 6720620014 3 Spare parts list 1 Pump / Hydraulic assy 22/04/2009 6720620014 4 Pos description S-Nr ordering

More information

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & 101

More information

GVK Series (Steam-to-Steam) Clean Steam Generators

GVK Series (Steam-to-Steam) Clean Steam Generators Page 1 of 5 TI-P486-03 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 GVK Series (Steam-to-Steam) Clean Steam Generators Description Unfired clean steam generators with 'U' type extractable tube bundle and

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SIT Group 822 NOVAMIX MULTIFUNCTIONAL GAS CONTROL GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SERVO-CONTROLLED PRESSURE REGULATOR PIN

More information