MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration

Size: px
Start display at page:

Download "MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration"

Transcription

1 MI Heating Cable HDPE jacketed, copper sheathed MI cable For surface snow melting in concrete, asphalt, and pavers Pipe Freeze Protection and Flow Maintenance Fire Sprinkler System Freeze Protection MI Heating Cable Configuration Type SUA Heated length length NPT threaded connector Product Overview The copper-sheathed, mineral insulated heating cables are covered with an extruded high-density polyethylene (HDPE) jacket and are supplied as complete factory-assembled cables ready to connect to a junction box. The series-type technology, inherent to all mineral insulated heating cables, provides a reliable and consistent heat source that is ideal for embedded snow melting applications. Roof and Gutter De-Icing Type SUB length Heated length length NPT threaded connector The copper sheath provides an ideal ground path and allows for a rugged yet flexible heating cable that is easy to install. For additional information, contact your Pentair Thermal Management representative or call (800) Melting MI Cable Construction Heating cable Jacket HDPE Sheath Seamless copper Insulation Magnesium oxide Conductor type Alloy or copper Number of conductors 1 Insulation voltage rating 600 V Cable diameter (with jacket) to in (5.1 to 7.7 mm) Jacket HDPE Sheath Seamless copper Insulation Magnesium oxide Conductor type Copper Number of conductors 1 or 2 Insulation voltage rating 600 V Cable diameter (with jacket) to in (7.9 to 10.7 mm) Gland size (NPT) 1/2 in Tail length 12 in (30 cm) Minimum installation temperature 4 F ( 20 C) Minimum bending radius 6 times cable diameter 1 / 6 Melting ElectroMelt Freezer Frost Heave Prevention Floor Heating Technical Data Sheets

2 mi heating cable for surface snow melting SUA/SUB Heating Cable Specifications Catalog number 120 Volts Configuration Heating cable reference Heated length Nominal Cable Cold Nominal cable power voltage length1 lead Joint diameter (ft) (m) (watts) (volts) (ft) (m) code type (in) (mm) Resistance2 (ohms) SUA5 A 61HD H22A Y SUA9 A 61HD H22A Y Volts SUA4 A 61HD H22A Y SUA7 A 61HD H22A Y SUB1 B 61HE H25A Y SUB3 B 61HE H30A Y SUB5 B 61HE H40A Y SUB7 B 61HE H40A Y SUB9 B 61HC H60A Y SUB10 B 61HC H80A Y SUB1402 B 61HD H25A Y SUB1702 B 61HD H25A Y SUB2002 B 61HD H25A Y SUB2402 B 61HD H25A Y SUB2802 B 61HE H25A Y SUB3402 B 61HE H25A Y SUB3902 B 61HE H25A Y SUB4502 B 61HE H25A Y SUB5502 B 61HE H30A Y SUB6402 B 61HE H40A Y SUB7802 B 61HE H40A Y SUB10302 B 61HC H60A Y SUB12802 B 61HC H80A Y SUB16102 B 61HC H80A Y Volts SUA3 A 61HD H22A Y SUA8 A 61HE H22A Y SUB2 B 61HE H25A Y SUB3 B 61HE H30A Y SUB4 B 61HE H30A Y SUB5 B 61HE H40A Y SUB6 B 61HE H40A Y SUB7 B 61HE H40A Y SUB8 B 61HC H60A Y SUB9 B 61HC H60A Y SUB10 B 61HC H80A Y SUB1604 B 61HD H25A Y SUB2004 B 61HD H25A Y SUB2304 B 61HD H25A Y SUB2804 B 61HD H25A Y SUB3204 B 61HE H25A Y To modify cold lead length, contact your Pentair Thermal Management sales representative. 2 Resistance tolerance: +/ 10% Tolerance on heating cable length: 0% to +3% Tail size (AWG) 2 / 6 EN-PyrotenaxMISurfaceSnowMelting-DS-H /13 THERMAL MANAGEMENT SOLUTIONS

3 SUA/SUB Heating Cable Specifications Catalog number Configuration 240 Volts, cont. Heating cable reference Heated length Nominal Cable Cold Nominal cable power voltage length1 lead Joint diameter (ft) (m) (watts) (volts) (ft) (m) code type (in) (mm) Resistance2 (ohms) SUB3904 B 61HE H25A Y SUB4504 B 61HE H25A Y SUB5204 B 61HE H25A Y SUB6404 B 61HE H30A Y SUB7304 B 61HE H40A Y SUB9004 B 61HE H40A Y SUB11904 B 61HC H60A Y SUB14704 B 61HC H80A Y SUB18604 B 61HC H80A Y Volts and 480 Volts, 3-phase Wye SUA3 A 61HD H22A Y SUA8 A 61HE H22A Y SUB2 B 61HE H25A Y SUB3 B 61HE H30A Y SUB4 B 61HE H30A Y SUB6 B 61HE H40A Y SUB8 B 61HC H60A Y SUB9 B 61HC H60A Y SUB15 B 61HE H25A Y SUB16 B 61HE H25A Y SUB17 B 61HE H40A Y SUB18 B 61HC H60A Y SUB1807 B 61HD H25A Y SUB2307 B 61HD H25A Y SUB2707 B 61HD H25A Y SUB3207 B 61HD H25A Y SUB3807 B 61HE H25A Y SUB4507 B 61HE H25A Y SUB5207 B 61HE H25A Y SUB6007 B 61HE H25A Y SUB7307 B 61HE H30A Y SUB8507 B 61HE H40A Y SUB10307 B 61HE H40A Y SUB13707 B 61HC H60A Y SUB17207 B 61HC H80A Y To modify cold lead length, contact your Pentair Thermal Management sales representative. 2 Resistance tolerance: +/ 10% Tolerance on heating cable length: 0% to +3% mi heating cable for surface snow melting Tail size (AWG) 3 / 6 Pipe Freeze Protection and Flow Maintenance Fire Sprinkler System Freeze Protection Roof and Gutter De-Icing Melting MI Melting ElectroMelt Freezer Frost Heave Prevention Floor Heating Technical Data Sheets

4 mi heating cable for surface snow melting SUA/SUB Heating Cable Specifications Catalog number Configuration Heating cable reference 347 Volts and 600 Volts, 3-phase Wye Heated length Nominal Cable Cold Nominal cable power voltage length1 lead Joint diameter (ft) (m) (watts) (volts) (ft) (m) code type (in) (mm) Resistance2 (ohms) SUB2305 B 61HD H25A Y SUB2905 B 61HD H25A Y SUB3405 B 61HD H25A Y SUB4105 B 61HD H25A Y SUB4705 B 61HE H25A Y SUB5605 B 61HE H25A Y SUB6505 B 61HE H25A Y SUB7505 B 61HE H25A Y SUB9205 B 61HE H30A Y SUB10605 B 61HE H40A Y SUB13005 B 61HE H40A Y SUB17205 B 61HC H60A Y Volts SUB19 B 61HD H25A Y SUB20 B 61HE H25A Y SUB21 B 61HE H25A Y SUB22 B 61HE H25A Y SUB3208 B 61HD H25A Y SUB4008 B 61HD H25A Y SUB4708 B 61HD H25A Y SUB5708 B 61HD H25A Y SUB6608 B 61HE H25A Y SUB7908 B 61HE H25A Y SUB9008 B 61HE H25A Y SUB10408 B 61HE H25A Y SUB12808 B 61HE H30A Y SUB14808 B 61HE H40A Y SUB18008 B 61HE H40A Y Volts SUB11 B 61HD H25A Y SUB12 B 61HD H25A Y SUB13 B 61HE H25A Y SUB14 B 61HE H25A Y SUB4006 B 61HD H25A Y SUB5106 B 61HD H25A Y SUB5806 B 61HD H25A Y SUB7106 B 61HD H25A Y SUB8206 B 61HE H25A Y SUB9806 B 61HE H25A Y SUB11206 B 61HE H25A Y SUB13006 B 61HE H25A Y SUB15906 B 61HE H30A Y To modify cold lead length, contact your Pentair Thermal Management sales representative. 2 Resistance tolerance: +/ 10% Tolerance on heating cable length: 0% to +3% Tail size (AWG) 4 / 6 EN-PyrotenaxMISurfaceSnowMelting-DS-H /13 THERMAL MANAGEMENT SOLUTIONS

5 Approvals mi heating cable for surface snow melting Nonhazardous Locations Pipe Freeze Protection and Flow Maintenance Ground-Fault Protection 421H To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of Pentair Thermal Management, agency certifications, and national electrical codes, ground-fault equipment protection must be used on each heating cable branch circuit. Arcing may not be stopped by conventional circuit protection. Many DigiTrace control and monitoring systems meet the ground-fault protection requirement. Fire Sprinkler System Freeze Protection Roof and Gutter De-Icing Melting MI Melting ElectroMelt Freezer Frost Heave Prevention 5 / 6 Floor Heating Technical Data Sheets

6 NORTH AMERICA Tel: Fax: Tel: Fax: Europe, Middle East, Africa Tel: Fax: Asia Pacific Tel: Fax: Latin America Tel: Fax: Pentair, Pyrotenax, and DigiTrace are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice Pentair. 6 / 6

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For heat loss replacement, floor heating and radiant space heating

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For heat loss replacement, floor heating and radiant space heating MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE For heat loss replacement, floor heating and radiant space heating MI Configuration Type SUA Design A Heated length lead length PRODUCT

More information

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE For commercial and industrial applications Heating cable construction Insulation (magnesium oxide) Heating conductor Copper sheath HDPE

More information

Product Overview. Application

Product Overview. Application Self-Regulating SC, SC/H Series-resistance heating cables for longline systems Electrical freeze protection for long pipelines in both nonhazardous and hazardous locations Power-Limiting Mineral Insulated

More information

XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES cable construction Corrugated stainless steel 316L outer sheath Insulation (magnesium oxide) conductors (dual)

More information

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket SELF-REGULATING HEATING CABLE For pipe freeze protection and flow maintenance Heating cable construction Tinned-copper braid Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket Modified polyolefin

More information

STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES Insulation (magnesium oxide) conductors (dual) Corrugated stainless steel 316L outer sheath Alloy 825 sheath cable

More information

MI Heating Cable for Surface Snow Melting

MI Heating Cable for Surface Snow Melting MI Cable for Surface Snow Melting. Pipe Freeze Protection and Flow Maintenance Visit www.tycothermal.com for more information on our ten-year extended warranty. Pyrotenax brand copper sheath mineral insulated

More information

SURFACE SNOW MELTING MI MINERAL INSULATED HEATING CABLE SYSTEM

SURFACE SNOW MELTING MI MINERAL INSULATED HEATING CABLE SYSTEM SURFACE SNOW MELTING MI MINERAL INSULATED HEATING CABLE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem Mineral Insulated heating cable surface snow melting system.

More information

Power-Limiting Cables

Power-Limiting Cables Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your

More information

C A Heating Cable Gland Kit Installation Instructions

C A Heating Cable Gland Kit Installation Instructions C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating

More information

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

COPPER SHEATHED, MINERAL INSULATED FIRE-RATED WIRING CABLE

COPPER SHEATHED, MINERAL INSULATED FIRE-RATED WIRING CABLE PYOTENAX SYSTEM 1850 COPPE SHEATHED, MINEAL INSULATED FIE-ATED IING CALE Cable construction Magnesium oxide (MgO) insulation Solid copper conductors HDPE jacket (optional) Seamless copper sheath PODUCT

More information

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P with Pyrotenax MI heating cable using required MI cable grounding kit SPC-P with Raychem

More information

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions Description The JBS-100-STB is a NEMA 4X rated power connection kit. It is designed for use with Raychem BTV-CR, BTV-CT,

More information

QUICKTERM TERMINATION KIT

QUICKTERM TERMINATION KIT PYROTENAX QUICKTERM TERMINATION KIT INSTALLATION INSTRUCTIONS FOR TERMINATING SINGLE CONDUCTOR COPPER SHEATHED MINERAL INSULATED CABLE DESCRIPTION This termination kit is used to terminate #6 AWG and larger

More information

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions JBM-100-STB NEMA 4X-rated connection kit Installation Instructions Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box Approvals Hazardous Locations CLI,

More information

ALLOY 825 SHEATHED, MINERAL INSULATED, FIRE-RATED WIRING CABLE

ALLOY 825 SHEATHED, MINERAL INSULATED, FIRE-RATED WIRING CABLE PYOTENAX SYSTEM 2000 ALLOY 825 SHEATHED, MINEAL INSULATED, FIE-ATED IING CALE Cable construction Seamless Alloy 825 metal sheath Magnesium oxide (MgO) insulation Solid nickel-clad copper conductors PODUCT

More information

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS DESCRIPTION The JBS-100-A and JBS-100-A6 are NEMA 4X-rated power connection kit. It is designed for use with Raychem

More information

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS DESCRIPTION The PolyMatrix PMKG-JS is a NEMA 4X rated splice connection kit for use with Raychem BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT

More information

Heating Cable. Construction

Heating Cable. Construction MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)

More information

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions Description The PolyMatrix PMKG-J2LP is a NEMA 4X rated connection kit for use with Raychem BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT and

More information

Heating Cable. Construction

Heating Cable. Construction Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant

More information

Self-regulating cables

Self-regulating cables Self-Regulating Self-regulating cables This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

XMI Mineral Insulated Heating Cables

XMI Mineral Insulated Heating Cables XMI Mineral Insulated Heating Cables This section provides an overview and general design guidelines for mineral insulated heat-tracing systems. For complete design assistance, contact your Pentair Industrial

More information

V (For 120, 208, 277, 600 V, please call.) Output: 37 W/ft 2 and 50W/ft 2 Cold lead:

V (For 120, 208, 277, 600 V, please call.) Output: 37 W/ft 2 and 50W/ft 2 Cold lead: Snow Melting Mats Data Sheet GENERAL PRODUCT INFORMATION ProLine snow melting mats feature pre-spaced heat cable (3 and 4-inch spacing) in mats that can be rolled out for quick, easy installation. To make

More information

SELF-REGULATING CABLES

SELF-REGULATING CABLES Self-Regulating SELF-REGULATING CABLES This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the

More information

ElectroMelt System INSTALLATION AND OPERATION MANUAL FOR SURFACE SNOW MELTING AND ANTI-ICING SYSTEMS

ElectroMelt System INSTALLATION AND OPERATION MANUAL FOR SURFACE SNOW MELTING AND ANTI-ICING SYSTEMS ElectroMelt System INSTALLATION AND OPERATION MANUAL FOR SURFACE SNOW MELTING AND ANTI-ICING SYSTEMS THERMAl MANAGEMENT WWW.PENTAIRTHERMAl.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

XL-Trace. Self-regulating conductive core. Nickel-plated copper bus wire

XL-Trace. Self-regulating conductive core. Nickel-plated copper bus wire Visit www.tycothermal.com for more information on our ten-year extended warranty. Raychem XL-Trace is designed for pipe freeze protection and flow maintenance in the following applications: Freeze protection

More information

Self-Regulating Cables

Self-Regulating Cables Self-Regulating 1. Self- Regulating 2. Power- Limiting This step-by-step design guide provides the tools necessary to design a self-regulating heat-tracing system for insulated pipes and tubing. For other

More information

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,

More information

3M Self Regulating Heating Cables

3M Self Regulating Heating Cables 2 Construction & Function 3M Self Regulating Heating Cables Introduction: 3M Canada and Thermon Manufacturing Company have entered into a strategic alliance to market the commercial line of heat tracing

More information

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS MIQ INSTALLATION INSTRUCTIONS MIQ CATALOGUE REF. NO. Example: D / MIQ-50E3H-2S / 200 / 1404 / 120 / 4 / 12 / 6 Design (A,B,D,E) Cable Reference Length (Feet or Meters) Watts Volts Cold Lead Length (Feet

More information

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace pipe freeze protection or flow maintenance system. For

More information

In-Pipe Retro 240 V In-pipe freeze protection heating cable Installation Instructions

In-Pipe Retro 240 V In-pipe freeze protection heating cable Installation Instructions all In-Pipe Retro 240 V In-pipe freeze protection heating cable Installation Instructions Approvals Type PS, X Made in Canada Kit Contents Item Qty Note: This product is suitable for use in potable water.

More information

Power Connection Kit installation instructions

Power Connection Kit installation instructions Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and

More information

H900 WinterGard Power Connection Kit with End Seal Installation Instructions

H900 WinterGard Power Connection Kit with End Seal Installation Instructions H900 WinterGard Power Connection Kit with End Seal Installation Instructions Power connection for H311, H611, and H621 Power connection for H612 and H622 Description The WinterGard power connection kit

More information

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.

More information

120/240 Volts 3 Watt Floor Heating Cable System

120/240 Volts 3 Watt Floor Heating Cable System WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable

More information

Heating Cables. For Industry Tracing

Heating Cables. For Industry Tracing Heating Cables For Industry Tracing FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length

More information

HAK-C-100 CONNECTION KIT FOR DIVISION 1 HAZARDOUS LOCATIONS INSTALLATION INSTRUCTIONS

HAK-C-100 CONNECTION KIT FOR DIVISION 1 HAZARDOUS LOCATIONS INSTALLATION INSTRUCTIONS HAK-C-100 CONNCTION KIT FO DIVISION 1 HAZADOUS LOCATIONS INSTALLATION INSTUCTIONS APPOVALS Hazardous Locations (1) (1) xcept VPL. KIT CONTNTS Class I, Div. 1, Groups B, C, D Class II, Div. 1, Groups, F,

More information

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal building solutions WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK

More information

FREEZSTOP MICRO SYSTEM

FREEZSTOP MICRO SYSTEM FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 25mm diameter water pipe at +5

More information

Easy-to-Install General-Purpose Cartridge Seal EZ-1

Easy-to-Install General-Purpose Cartridge Seal EZ-1 Easy-to-Install General-Purpose Cartridge Seal EZ-1 Cartridge-Mounted Bellows Seal EZ-1 Cartridge-Mounted Bellows Seal Technology With over 25,000 field installations, the performance-proven EZ-1 general-purpose

More information

The advantages of the pipe tracing systems are: Sensor. Insulation Heating cable Aluminium tape. Fig. 1 Fig. 2

The advantages of the pipe tracing systems are: Sensor. Insulation Heating cable Aluminium tape. Fig. 1 Fig. 2 28 3 Pipe tracing 3.1 General information DEVI s pipe tracing systems consist of deviflex heating cables, devireg thermostats and installation accessories. The devireg thermostats with sensors ensure that

More information

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths

More information

HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES

HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES THERMAL MANAGEMENT SOLUTIONS WWW.THERMAL.PENTAIR.COM Important Safeguards and Warnings

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

In-Pipe Retro 120 V IN-PIPE FREEZE PROTECTION HEATING CABLE INSTALLATION INSTRUCTIONS

In-Pipe Retro 120 V IN-PIPE FREEZE PROTECTION HEATING CABLE INSTALLATION INSTRUCTIONS In-Pipe Retro 120 V IN-PIPE FREEZE PROTECTION HEATING CABLE INSTALLATION INSTRUCTIONS DESCRIPTION Raychem In-Pipe Retro is a high wattage in-pipe heating cable designed for freeze protection of uninsulated

More information

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath Introduction to Heat Trace Cable Systems...6-2 Mineral Insulated Heat Trace Cable...6-2 Non-Metallic Sheath Heat Trace Cable...6-2 Installation Details...6-4 Engineering Guide for Mineral Insulated Cable...6-5

More information

Heat Tracing Products

Heat Tracing Products Applications Electric Industrial Process Maintenance Applications Commercial Applications Chromalox heating cable line includes cables suitable for most process maintenance, pipe and vessel freeze protection

More information

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant

More information

INSTALLATION PRODUCTION TESTS

INSTALLATION PRODUCTION TESTS Deadbreak Apparatus Connectors 600 A 15/25 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-10 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class Bol-T Deadbreak Connector is used to terminate

More information

Warm Tiles Troubleshooting. Al & Jed

Warm Tiles Troubleshooting. Al & Jed Warm Tiles Troubleshooting Al & Jed C O N T E N T S DFT Cable Construction (p.1) An overview of how the cable is built and what comprises the cable. Types of Cable Faults (p.4) Discusses the different

More information

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system installation guide l 1 Uponor Ecoflex potable PEX plus pre-insulated pipe system

More information

THERMAL MANAGEMENT

THERMAL MANAGEMENT DESIGN GUIDELINES XL-TRACE LSZH SELF-REGULATING HEATING CABLES FOR PIPE FREEZE PROTECTION SYSTEMS THERMAL MANAGEMENT WWW.PENTAIRTHERMAL.COM PIPE FREEZE PROTECTION SYSTEM OVERVIEW SBS Control Panel T-Connection

More information

SURFACE SNOW MELTING AND ANTI-ICING ELECTROMELT SYSTEM

SURFACE SNOW MELTING AND ANTI-ICING ELECTROMELT SYSTEM SURFACE SNOW MELTING AND ANTI-ICING ELECTROMELT SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem ElectroMelt heating cable surface snow melting and anti-icing system.

More information

Kompensator External Low Voltage Heating Cable System

Kompensator External Low Voltage Heating Cable System External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................

More information

METAL BELLOWS CARTRIDGE SEAL. Operating Conditions

METAL BELLOWS CARTRIDGE SEAL. Operating Conditions S--E Applications The Type is a metal bellows cartridge seal with computer optimised asymmetric bellows. General industrial applications including chemical processing, mining, pulp and paper and wastewater

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series) PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

PDU Input Power Cord. Before installation. Specifications

PDU Input Power Cord. Before installation. Specifications PDU Input Power Cord Before installation Before you install the PDU Input Power Cord, see the installation manual included with your PDU for pre-installation instructions and safety information. Select

More information

Self-regulating heating cables with a non-heating service cable

Self-regulating heating cables with a non-heating service cable N144/R02(22.08.18) Self-regulating heating cables with a non-heating service cable ELSR-M-15-2-BO ELSR-N--2-AO ELSR-N-30-2-AO GENERAL CONDITIONS The connector which connects the cold end and the heating

More information

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating

More information

ET-PWR-END-KIT Installation Instructions (part #JSR00)

ET-PWR-END-KIT Installation Instructions (part #JSR00) (part #JSR00) Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety

More information

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751 ata Sheet 902210 Page 1/12 Mineral-Insulated RT Temperature Probe According to IN EN 60751 For temperatures from -50 (-200) to +600 C Flexible sheath cable with vibration-resistant measuring insert As

More information

Pipeline Accessories. Hydraulic wedge mandrels Bending sets Line-up clamps Roli-cradles

Pipeline Accessories. Hydraulic wedge mandrels Bending sets Line-up clamps Roli-cradles Pipeline Accessories Hydraulic wedge mandrels Bending sets Line-up clamps Roli-cradles PIPELINE ACCESSORIES PERFECT COMPLEMENT TO YOUR BENDING MACHINE In addition to the full range of pipe bending machines,

More information

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG COMPANY OVERVIEW Since 1970, we have been pioneering new developments in heater technology and providing

More information

TYPE 7700D/7700W DOUBLE OPPOSED CARTRIDGE MIXER SEAL

TYPE 7700D/7700W DOUBLE OPPOSED CARTRIDGE MIXER SEAL A Seat/Mating Ring B Face/Primary Ring C Retainer D Sleeve E Collar F Gland Plate F E D C A B Product Description The Type 7700 Series is a heavy-duty cartridge seal intended for use in critical mixing

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner

More information

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Wiper Parking Area Defrosters

Wiper Parking Area Defrosters Clear View II FWH HD Wiper Parking Area High density elements for better heating Defrost the windshield low in the wiper parking area Keep wipers moving, cut snow build up In tough winter conditions snow

More information

Self-Regulating Parallel Heating Cables. innovations in heat tracing

Self-Regulating Parallel Heating Cables. innovations in heat tracing Self-Regulating Parallel Heating Cables innovations in heat tracing ELSR Application Options The application options for the ELSR heating cables range from freeze protection to maintenance of pipes and

More information

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife

More information

NELSON SNOW MELTING SYSTEM

NELSON SNOW MELTING SYSTEM Alloy Sheath Custom Fabricated MI Cable Heating Elements Magnesium Oxide Insulation Application: Electric heating of paved surfaces Electrical snow melting systems replace offer an effective alternative

More information

INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES

INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES Page 1 of 18 The PRL LED Point Rollover Light is used for heliport TLOF and FATO applications where an inset light is required. The thick soda lime glass

More information

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Heating systems protect pipes, valves, actuators and other elements vulnerable to harmful influence

More information

Mineral Insulated Resistance Thermometers (RTD)

Mineral Insulated Resistance Thermometers (RTD) Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types

More information

Heating Cable. Cut to Length in Field. Description

Heating Cable. Cut to Length in Field. Description Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

Innovative Access Solutions

Innovative Access Solutions Innovative Access Solutions Table of Contents Table of Contents Product Description Page Innovative Access Solutions Captive Hinge Access Assembly ERGO Access Assembly ERGO XL Access Assembly 8210 Heavy

More information

Pipe Freeze Protection Design/Install Guide

Pipe Freeze Protection Design/Install Guide Pipe Freeze Protection Design/Install Guide Page 1 of 16 Pipe Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 STEP 1 Information Required Page 4 STEP 2 Design Considerations Page

More information

TYPE FFET SINGLE CARTRIDGE O-RING SEAL Technical Specification

TYPE FFET SINGLE CARTRIDGE O-RING SEAL Technical Specification A Seat/Mating Ring B Face/Primary Ring C Spring D Sleeve E Quench/Drain F Flush G Safety Bushing D E C G A B F Product Description The FFET cartridge seal has been designed to reduce installation time

More information

Cable thermocouple Model TC40

Cable thermocouple Model TC40 Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 Applications For direct installation into the process Machine building Motors Bearings Pipelines and vessels Special

More information

Hot runner thermocouple Model TC46

Hot runner thermocouple Model TC46 Electrical temperature measurement Hot runner thermocouple Model TC46 WIKA data sheet TE 65.46 for further approvals see page 7 Applications Plastics and rubber industry Hot runner bushings, drops and

More information

FLEXIBLE HEATED HOSES

FLEXIBLE HEATED HOSES FLEXIBLE HEATED HOSES TYPE ELH UP TO 350 C AND EX FOR HAZARDOUS ZONES The ideal solution that eltrace offers to the transportation of liquids and gases. Long life, high resistance to temperature uniform

More information

Electric Heat Tracing INSTALLATION PROCEDURES

Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing Complete Electric Heat Tracing System... Illustration A: Typical Heat Tracing Installation A complete electric heat tracing system will

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 310 310.120 CHANGES FROM 2011 TO 2014 CODE ARE IN RED ARTICLE 310 Conductors for General Wiring I. General 310.2 Definitions Electrical Ducts Electrical conduits, or other

More information

Steel Outlet Boxes 4 11 /16" Welded

Steel Outlet Boxes 4 11 /16 Welded Steel Outlet Boxes 4 11 /16" Welded Steel Outlet Boxes Features & Benefits Ideal for exposed work applications, providing an easy method for the installation of electrical devices (switches, receptacles,

More information

The bonded pipe system Overview

The bonded pipe system Overview 2.0.0.1 Overview Introduction This section contains a description of the preinsulated single s which LOGSTOR offers. Contents Material specifications 2.0.1 District heating s, insulation series 1 2.0.2

More information

SUBMERSIBLE ELECTRIC ECTRIC MOTOR KM6 6

SUBMERSIBLE ELECTRIC ECTRIC MOTOR KM6 6 SUBMERSIBLE ELECTRIC ECTRIC 60 MOTOR KM6 6 6-inch Water Cooled Series 6 Borehole Submersible Motors KM6 2 60 Poles KOMAX (Private) Limited, an ISO 900:205 certified company, has the pride to say that it

More information

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL Deadbreak Apparatus Connectors 600 A 15/25 kv Class BOL-T Deadbreak Connector Electrical Apparatus 600-30 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class BOL-T Deadbreak Connector is used to terminate

More information

for Instrumentation and Hydraulic Systems

for Instrumentation and Hydraulic Systems Seamless Stainless steel Tubes for Instrumentation and Hydraulic Systems Standards: ASME SA-213/SA-213M; ASTM A269/269M; ASME SA-312/SA312M; ASME SA-789/SA-789M; ASME SB-163; ASME SB-444; EN 10216-5; EN

More information

PD10 PILE DRIVER PD10 PILE DRIVER

PD10 PILE DRIVER PD10 PILE DRIVER PD10 PILE DRIVER PD10 PILE DRIVER To learn more and see the PD10 pile driver in action, scan this code with your smartphone or go to piledriver. vermeer.com A customer-minded solution for solar worldwide.

More information

HERAEUS LABOFUGE 400 AND 400 R GENERAL PURPOSE CENTRIFUGES. Great value and functionality for routine work

HERAEUS LABOFUGE 400 AND 400 R GENERAL PURPOSE CENTRIFUGES. Great value and functionality for routine work HERAEUS LABOFUGE 400 AND 400 R GENERAL PURPOSE CENTRIFUGES Great value and functionality for routine work The Labofuge 400 tabletop centrifuge and the refrigerated version, the Labofuge 400 R, are ideal

More information