PRESSURE SUPPLY UNITS SERIES DH 2000 HYDRAULIC POWER PACKS & HYDRAULIC UNITS

Size: px
Start display at page:

Download "PRESSURE SUPPLY UNITS SERIES DH 2000 HYDRAULIC POWER PACKS & HYDRAULIC UNITS"

Transcription

1 PRESSURE SUPPLY UNITS SERIES DH 2000 HYDRAULIC POWER PACKS & HYDRAULIC UNITS The Dellner hydraulic power pack series DH 2000 are available in four different models, each with several different options. The main functions of the different models are as follows: DH 2100: On/Off unit with an optional accumulator. DH 2200: Unit with Separate function available as an option to make it possible to pressurise two braking systems individually and independently. Other options are an accumulator, hand pump and pressure switches. DH 2300: Unit with proportional s that gives the possibility to achieve a controlled operation by programming any kind of braking curve, controlled by an optional PLC in an electrical terminal box. Other options are an accumulator and hand pump. DH 2400: Unit with Double control s for critical applications such as overhead cranes, etc. Other options are an accumulator, hand pump, pressure switches and additional filter unit. All four models can be delivered with optional hydraulic s and electrical terminal boxes. The optional s/boxes for all four models have the same dimensions. The electrical terminal boxes can be delivered with optional rapid connectors and/or fireproof cables.

2 DH 2100 DH 2100 is an ON/OFF unit with an optional accumulator, hydraulic and electrical terminal box. Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Accumulator Pressure switch 1 terminal box 2 1) For example, the pressure switch can be used to indicate hydraulic pressure ON/OFF 2) The electrical terminal box is only available when the hydraulic power pack is delivered with a hydraulic i.e. as a hydraulic unit. The electrical terminal boxes can be delivered with optional rapid connectors and/or fireproof cables. DH DH 2100 unit with, 110 VAC and optional accumulator (without pressure switch, hydraulic and electrical

3 DH 2200 DH 2200 is a unit with Separate function available as an option to make it possible to pressurise two braking systems individually and independently. Other options are an accumulator, hand pump and pressure switches. Separate function 1 Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Pos. 6 Pos. 7 Pos. 8 Pos. 9 Type Accumulator Hand Pressure Pressure of pump switch 2 switches 3 s N/A N/A 5 N/A N/A 5 terminal box 4 1) Separate function only needed when pressurising two braking systems individually by using two separate control s (see pos. 1) 2) For example, pressure switch can be used to indicate "low hydraulic pressure" 3) For example, pressure switches can be used to indicate "hydraulic pressure ON/OFF" 4) The electrical terminal box is only available when the hydraulic power pack is delivered with a hydraulic i.e. as a hydraulic unit. The electrical terminal boxes can be delivered with optional rapid connectors and/or fireproof cables. 5) If accumulator (Pos. 5) is chosen a - (Pos. 2) and a manual (Pos. 4) always are included. DH DH 2200 unit with separate function,, 110 VAC, an optional accumulator and hand pump (without pressure switches, hydraulic and electrical

4 DH 2300 DH 2300 is a unit with proportional s that gives the possibility to achieve a controlled operation by programming any kind of braking curve, controlled by an optional PLC in an electrical terminal box. Other options are an accumulator and hand pump. INTERFACE / CONTROL Customer supplies control signal(s) and DH 2300 generates one of following alternatives: A controlled braking curve A number of different pressure settings (braking forces) depending on the different control signals (ma) supplied by customer. Braking torque [Nm] Braking time [s] Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Pos. 6 Pos. 7 Accumulator Hand pump Needle Pressure switch 1 terminal box 2 1) For example, the pressure switch can be used to indicate hydraulic pressure ON/OFF 2) The electrical terminal box is only available when the hydraulic power pack is delivered with a hydraulic i.e. as a hydraulic unit. The electrical terminal boxes can be delivered with optional rapid connectors and/or fireproof cables. DH DH 2100 unit with, 110 VAC and an optional accumulator (without hand pump, needle, pressure switch, hydraulic and electrical

5 DH 2400 DH 2400 is a unit with Double control s for critical applications such as overhead cranes, etc. Other options are an accumulator, hand pump, pressure switches and additional filter unit. Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Pos. 6 s N/A 3 N/A 4 Additional filter unit Pos. 7 Pos. 8 Pos. 9 Pos. 10 Pos. 11 Accumulator Hand pump Pressure Switch 1 Temperature sensor terminal box 2 1) For example, the pressure switches can be used to indicate "hydraulic pressure ON/OFF" 2) The electrical terminal box is only available when the hydraulic power pack is delivered with a hydraulic i.e. as a hydraulic unit. The electrical terminal boxes can be delivered with optional rapid connectors and/or fireproof cables. 3) Always -s. 4) If accumulator (Pos. 7) is chosen a manual - (Pos. 2) always is included. DH DH 2400 unit with 110 VAC, additional filter unit, an optional accumulator and hand pump (without pressure switch, temperature sensor, hydraulic and electrical

THE STL-SYSTEM STL CONFIGURATION EXAMPLES A MULTI-FUNCTION UNIT ALL CONTAINED IN ONE CUSTOMER INTERFACE

THE STL-SYSTEM STL CONFIGURATION EXAMPLES A MULTI-FUNCTION UNIT ALL CONTAINED IN ONE CUSTOMER INTERFACE PRODUCT FOLDER THE STL-SYSTEM A MULTI-FUNCTION UNIT ALL CONTAINED IN ONE CUSTOMER INTERFACE THE STL-SYSTEM OFFERS YOU ONE OR SEVERAL OF THREE FUNCTIONS Stopping: Dellner Brakes hydraulic or electric disc

More information

SELF-CONTAINED ELECTRO-HYDRAUIC CONTROL SYSTEMS

SELF-CONTAINED ELECTRO-HYDRAUIC CONTROL SYSTEMS SELF-CONTAINED ELECTRO-HYDRAUIC CONTROL SYSTEMS COMPANY For over 30 years Paladon Systems has been supplying valve actuators and control systems on a global basis. Since its inception in 1981, Paladon

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

VAHLE POWERCOM 485. Digital Data Transmission System

VAHLE POWERCOM 485. Digital Data Transmission System VAHLE POWERCOM 485 Digital Data Transmission System 19 12 VAHLE POWERCOM 485 GENERAL INFORMATION VAHLE POWERCOM 485 Digital Data Transmission using VAHLE Conductor Systems VAHLE POWERCOM 485 is the latest

More information

SBA01 SERIES BALL VALVE ACTUATOR

SBA01 SERIES BALL VALVE ACTUATOR SBA01 SERIES BALL VALVE ACTUATOR DESCRIPTION SBA01 series ball valve actuator is using bi-directional motor. Matching with DN15~DN25 SBV series ball valve, it is mainly used in central air-conditioning

More information

SNAG OVERLOAD SYSTEM SOS

SNAG OVERLOAD SYSTEM SOS sos_englisch_0812_layout 1 28.08.12 15:01 Seite 2 SNAG OVERLOAD SYSTEM System Layout and Description System Components w Malmedie Safety Coupling MSC II w PINTSCH BUBENZER LiTec low inertia brake disc

More information

Proportional Pressure Relief Valve Series RE*T

Proportional Pressure Relief Valve Series RE*T Characteristics The pressure relief valve series RE*T have a proportional solenoid operated pilot stage with integrated electronics and a cartridge main stage. Features Pilot-operated pressure relief valve

More information

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67 3 Technical data General characteristics Design Flow direction Seals De-energized position Mounting attitude Description, value, unit line mounting P A controlled P R surplus flow discharge (models shown

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

SECTION A FRONT END LOADER VALVES

SECTION A FRONT END LOADER VALVES NB: models, Codes and Specifications may be subject to change without notice. SECTION A FRONT END LOADER VALVES Valve Series Nominal PAGE WALVOIL FRONT-END LOADER VALVES SDM102 Series... 45L/Min... A 14

More information

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT Characteristics The D*1FW / D*1FT pilot-operated proportional DC valves are available in NG10 (CETOP5), NG16 (CETOP7) and NG25 (CETOP8). These valves (D*1FW) are controlled electrically with the external

More information

SECTION B1: MACHINE COMPONENTS

SECTION B1: MACHINE COMPONENTS SECTION B1: MACHINE COMPONENTS The machine portion of the Injected Metal Assembly system provides the means for: holding, heating and injecting the alloy; distributing and controlling electrical, pneumatic,

More information

SM-1000 SERIES ROTARY ACTUATORS

SM-1000 SERIES ROTARY ACTUATORS SM-1000 SERIES ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1000 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating positioning control. Designed

More information

V Series AXIAL PISTON PUMP ORDER CODE

V Series AXIAL PISTON PUMP ORDER CODE V Series AXIAL PISTON PUMP ORDER CODE V A 1 R B S - A D X A 1 Customers demand Pump Series V Links Type (only V -18): none - Standard A - SAE A bolts Ma. (cm 3 /n):, 18, 3,, 38, 4,, 7 Pump Control Type

More information

MULTI-JET WATER METERS

MULTI-JET WATER METERS MULTI-JET WATER METERS INSTALLATION INSTRUCTIONS General Information Technical Data 3 Features 3 Applications 3 Dimensions 3 Pulse Rate 3 Pressure Loss Curve 3 Shipping Weight 3 Installation Position 4

More information

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES 6. 9 ELECTRO-PROPORTIONAL VALVES ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES In the follow of this chapter, NEM presents the electro-proportional flow

More information

V Series AXIAL PISTON PUMP ORDER CODE

V Series AXIAL PISTON PUMP ORDER CODE V Series AXIAL PISTON PUMP ORDER CODE V 15 A 1 R B S - A 1 D X A 11 Customers demand Pump Series V Links Type (only V 15-18): none - Standard A - SAE A 2 bolts Ma. Displacement (cm 3 /n): 15, 18, 23, 25,

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

KWG145 SERIES. Lightly geared limit switch in Plastic housing. For Industrial, Crane s and Lockings. Product description.

KWG145 SERIES. Lightly geared limit switch in Plastic housing. For Industrial, Crane s and Lockings. Product description. For Industrial, Crane s and Lockings Easy Limit Switch up to 5 Channels Different micro switches Free programmable cams Protection class IP64 Protection against contact Product description Heavy duty geared

More information

TURBINE BYPASS SYSTEMS

TURBINE BYPASS SYSTEMS TURBINE BYPASS SYSTEMS Electro-Hydraulic Control Systems COMPANY For over 30 years Paladon Systems has been supplying valve actuators and control systems on a global basis. Since its inception in 1981,

More information

CONTENTS 1. 1 Power Units Overview Applications Models Power Units... 3

CONTENTS 1. 1 Power Units Overview Applications Models Power Units... 3 CONTENTS 1 Power Units Contents 1 Power Units 2 1.1 Overview........................................ 2 1.2 Applications...................................... 2 2 Models 3 2.1 Power Units......................................

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL

16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL 16-37 TM IRC Instruction Manual (99903542) 16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL 01.01 2007 IOWA MOLD TOOLING CO., INC. GARNER, IA 50438 1. Introduction... 2 2. The Components of the IRC-System...

More information

Reliable Electric Actuation for Industrial Control

Reliable Electric Actuation for Industrial Control P1 Quarter Turn Actuator Reliable Electric Actuation for Industrial Control P4 Quarter Turn Actuator Full Line of Actuators Quarter Turn to 40,000 in lb (4,500 Nm) Linear to 4400 lb force (2,000 kg) Spring

More information

USER-PROGRAMMABLE AND ROBUST

USER-PROGRAMMABLE AND ROBUST NC FREELY PROGRAMMABLE ROTARY TABLES NC ROTARY TABLE NC ROTARY TABLE: USER-PROGRAMMABLE AND ROBUST OPTIMISED BEARINGS To achieve maximum quality and reliability, even when under load, all roller bearings

More information

V130 Service Parts. Back Cap & Control Kits

V130 Service Parts. Back Cap & Control Kits V130 Service Parts Back Cap & Control Kits V130 Series Back-Cap Kit 3 Position Spring Return V130-BC-01 Item 3: Item 5: Apply multi-purpose grease prior to spring assembly Clean the threads on item 5 and

More information

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment Tekna Solenoid driven dosing pumps Your Choice, Our Commitment 02 Solutions for Water & Industry Five times the Flexibility A single outer casing contains 5 different models with flow rates ranging from

More information

12 VDC Solenoid. 24 VDC Solenoid. 12 VDC Solenoid. 24 VDC Solenoid. 12 VDC Solenoid. 24 VDC Solenoid

12 VDC Solenoid. 24 VDC Solenoid. 12 VDC Solenoid. 24 VDC Solenoid. 12 VDC Solenoid. 24 VDC Solenoid SERVICE AND OPERATING MANUAL Solenoid Valves AC Solenoids AC Solenoid Kits designed for use with the RuppTech Stroke Counter/Batch Controller, RuppTech Pulse Output Interface Kits, and customer-supplied

More information

LIFTMOORE TRUCK MOUNTED CRANES

LIFTMOORE TRUCK MOUNTED CRANES LIFTMOORE TRUCK MOUNTED CRANES Building Quality Since 1961 ESTABLISHED 1961 7810 Pinemont Dr. Houston, Texas 77040 713-688-5533 FAX: 713-688-6324 www.liftmoore.com Craftsmanship Dependability Quality LIFTMOORE

More information

MPPT-30 Solar Charge Controller

MPPT-30 Solar Charge Controller MPPT-30 Solar Charge Controller 30 AMP 12V/24V/48V PHOTOVOLTAIC CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL TABLE OF CONTENT 1. Introduction.3 2. Installation..4 3. Operation 6 4. Data Sheet 11

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

MOBILE CRANE BRANCH OF ZOOMLION GROUP

MOBILE CRANE BRANCH OF ZOOMLION GROUP QUY0 SPECIFICATIONS MOBILE CRANE BRANCH OF ZOOMLION GROUP -1- Content 1. Overall dimensions and main specifications 1.1 Overall dimensions and working weight of main machine with basic 1.2 Overall dimensions

More information

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification Table E3-/E Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-6/WP/6 On/off valves

More information

VAHLE POWERCOM 485. Digital Data Transmission System

VAHLE POWERCOM 485. Digital Data Transmission System VAHLE POWERCOM 485 Digital Data Transmission System 19 12 VAHLE POWERCOM 485 GENERAL INFORMATION VAHLE POWERCOM 485 Digital Data Transmission using VAHLE Conductor Systems VAHLE POWERCOM 485 is the latest

More information

TUBUS-Series Type TA

TUBUS-Series Type TA TUBUS-Series Type TA Profile Damper Axial Damping The profile damper type TA from the innovative ACE TUBUS series is a maintenancefree, self-contained damping element made from a special Co-Polyester Elastomer.

More information

TUBUS-Series Type TA

TUBUS-Series Type TA TUBUS-Series Type TA Profi le Damper Axial Damping 76 The profile damper type TA from the innovative ACE TUBUS series is a maintenance-free, self-contained damping element made from a special Co-Polyester

More information

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp 48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp E13224 The 48 series is a contactor with a 4 normally open, double make contacts rated up to 3HP. It uses a solenoid type moving core design

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34 Control Cartridge Valves: PSV10-34 & PSV12-34 SCHEMATIC PRESSURE* FLOW CAVITY COIL Page 2 PSV10-34-02 250 BAR 3600 PSI 22 LPM 6 GPM SDC10-4 M16-26W R16-20W Page 4 PSV12-34-02 260 BAR 3770 PSI 50 LPM 13

More information

4-Stroke Horizontal Engines

4-Stroke Horizontal Engines -Stroke Horizontal Engines FJ Series Output :. (. hp) - (. hp) FH Series Output :. (. hp) -. (. hp) FE Series Output :. (. hp) -. (. hp) FD Series Output :. (0. hp) - 0 (. hp) Engine Model FJ0 FJ FJ0 Engine

More information

Automated and precise static load testing with absolute control and high performance

Automated and precise static load testing with absolute control and high performance Automated and precise static load testing with absolute control and high performance ATLAS Pile Testing systems presents the Titan 650, for automated, remote controlled static load testing of piles and

More information

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators)

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators) Timer Board Suffix A Timer board installs within actuator enclosure. Board shown is for EVR, EVS, and EVT actuators. Cycle Time Rate Regulator Suffix B Cycle time rate regulator installs within actuator

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Pilot control unit with end position lock for the remote control of directional valves

Pilot control unit with end position lock for the remote control of directional valves Pilot control unit with end position lock for the remote control of directional valves RE 64 553/02.07 1/12 Replaces : 05.05 Type 4THF6 or 5THF6 Series 2X Contents Functional description, section, symbol

More information

VAHLE POWERCOM 485. Digital Data Transmission System

VAHLE POWERCOM 485. Digital Data Transmission System VAHLE POWERCOM 485 Digital Data Transmission System 19 12 VAHLE POWERCOM 485 GENERAL INFORMATION VAHLE POWERCOM 485 Digital Data Transmission using VAHLE Conductor Systems VAHLE POWERCOM 485 is the latest

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly

More information

35 35A 50 50A 1 Single phase. Solid state power controller

35 35A 50 50A 1 Single phase. Solid state power controller Single Phase, Power Controller Single Phase, Power Controller Features Various and simple input specification DC4-2mA, 1-5VDC, External 24VDC External adjuster (1kΩ) External contact (ON/OFF) Various function

More information

J1000. Compact Inverter Series.

J1000. Compact Inverter Series. J1000 Compact Inverter Series www.yaskawa.eu.com Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive

More information

Contact Details: Mail Id:

Contact Details: Mail Id: Product Brochure Contact Details: +91 8308839755 Mail Id: savikenterprises@yahoo.co.in Contents Solid State Relay... - 3 - Thyristor Heater/Power Controllers... - 6 - Emergency Alarm System... - 9 - Thyristor

More information

Solar water pumping system Goulds, 0.75HP 230Vac, 120psi Test Report -

Solar water pumping system Goulds, 0.75HP 230Vac, 120psi Test Report - Date: 4-2-2017 Solar water pumping system Goulds, 0.75HP 230Vac, 120psi Test Report - This report quantitatively documents the tested performance of a solar submersible water pumping system consisting

More information

FORMECH VACUUM FORMING MACHINES- DESKTOP

FORMECH VACUUM FORMING MACHINES- DESKTOP INTRODUCTION Arrow has pioneered many ground breaking technologies and has been a leader in the digital printing/cutting field since decades; providing digital printing solutions to the Indian market.

More information

Contents. Directional Control Valve 2 Series CV Unibody. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves

Contents. Directional Control Valve 2 Series CV Unibody. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves Contents Page 3-4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11-12 Page 13 Page 14 Page 15 General Information Technical data Performance Curves Dimensions - Basic Valve Dimensions - Unibody Secondary

More information

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features.

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features. Catalog HY14-2/US Technical Information General Description Series R4V and R6V proportional pressure relief valves feature onboard electronics based on the functionality of the digital amplifier PCD. The

More information

Dome Drive Electrical VFD System Upgrade

Dome Drive Electrical VFD System Upgrade Dome Drive Electrical VFD System Upgrade Steven Bauman Contributors: S. G a j a d h a r, D. S a l m o n, L. R o b e r t s, G. Matsushige, I. Look, R. Taroma, C. Elizares, T. Arruda, W. Cruise, T. Vermeulen,

More information

TA-6-way valve. Standard control valves 6-way valve for change-over systems

TA-6-way valve. Standard control valves 6-way valve for change-over systems TA-6-way valve Standard control valves 6-way valve for change-over systems IMI TA / Control valves and Actuators / TA-6-way valve TA-6-way valve The 6-way valve solution enables various control set-ups

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

PANASONIC Models: MC-9410, MC-9420, MC-9430, MC-9440

PANASONIC Models: MC-9410, MC-9420, MC-9430, MC-9440 Dust Cover and Attachments A1... P-12429... Indicator Plate, 9410 A1... P-12430... Indicator Plate, 9420 A1... P-12431... Indicator Plate, 9430 A1... P-12432... Indicator Plate, 9440 A2... P-12433... Indicator

More information

2.6. Air Flow Control Valve Type PRD

2.6. Air Flow Control Valve Type PRD 2.6. Air Flow Control Valve Type PRD Page 1/10 Air Flow Control Valve, Type PRD Page 2/10 Air Flow Control Valve Type PRD Description and Design The PRD remains the air valve of choice for critical heating,

More information

FLUORESCENT LAMP CONTROLLER & RAPID ONSET FLUORESCENT STIMULATOR

FLUORESCENT LAMP CONTROLLER & RAPID ONSET FLUORESCENT STIMULATOR instrumentation and software for research FLUORESCENT LAMP CONTROLLER & RAPID ONSET FLUORESCENT STIMULATOR PHM-258 & PHM-258L USER S MANUAL DOC-073 Rev. 1.2 Copyright 2012 All Rights Reserved Med Associates

More information

ECU1000 ELECTRONIC CONTROL UNIT

ECU1000 ELECTRONIC CONTROL UNIT An advanced electronic system capable to be integrated in a SMART Electro Hydraulic System for heavy modulating, stepping, PST, diagnostic and ESD/BDV actions FEATURES GENERAL APPLICATION is a control

More information

The Electromagnet. Electromagnetism

The Electromagnet. Electromagnetism The Electromagnet When you have completed this exercise, you will be able to explain the operation of an electromagnet by using a coil of wire. You will verify your results with a compass and an iron nail.

More information

Cat# 71712A LED Linear High Bay 120W

Cat# 71712A LED Linear High Bay 120W Cat# 7171A LED Linear High Bay 10W Dimming: DC 0-10V QPL ID # P1YP17JZ OVERALL LAMP PARAMETERS LED DRIVER LIFESPAN & ENVIRONMENT OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance

More information

BIROTATIONAL POWER PACK

BIROTATIONAL POWER PACK HYDRAULIC SYSTEMS DIVISION Outstanding Hydraulic Products, Service and Expertise, Worldwide FEATURES / BENEFITS Reduces wiring, leak paths and eliminates directional valves resulting in lower overall system

More information

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement Product Manual 36060 (Revision A, 8/2015) Original Instructions ProAct II Digital Speed Control System Technical Supplement DEFINITIONS This is the safety alert symbol. It is used to alert you to potential

More information

Tandem Fix 40 Ship to Shore Spreader

Tandem Fix 40 Ship to Shore Spreader A Tradition of Innovation Product Information Tandem Fix 40 Ship to Shore Spreader Load combinations with Tandem Fix 40 The spreader shown is equipped with extra accessories The Bromma Tandem Fix 40 spreader

More information

NB: models, Codes and Specifications may be subject to change without notice. SECTION A DIRECTIONAL CONTROL VALVES MANUAL DIRECTIONAL VALVES

NB: models, Codes and Specifications may be subject to change without notice. SECTION A DIRECTIONAL CONTROL VALVES MANUAL DIRECTIONAL VALVES NB: models, Codes and Specifications may be subject to change without notice. SECTION A DIRECTIONAL CONTROL VALVES MANUAL DIRECTIONAL VALVES Valve Series Page...... A 2 WALVOIL FRONT-END LOADER VALVES...

More information

Stainless Steel Pressure Filters

Stainless Steel Pressure Filters Stainless Steel Pressure Filters Inline Filters up to 26,000 PSIG up to 35 GPM Description Process Filtration MPSSF / HPSSF/ ACSSF Series The pressure filters consist of two main sections: the filter head

More information

for Critical Applications in Extreme Environments

for Critical Applications in Extreme Environments for Critical Applications in Extreme Environments Electronic Controllers M-CONTROL Electronic Controllers provide control for systems requiring fluid pressure and flow control via pumps, fans and compressors.

More information

All In one uninterruptible power supply solutions

All In one uninterruptible power supply solutions All In one uninterruptible power supply solutions For the life of your systems with Battery Care concept Integrated Electronic Solution Yet another strong proposition from Adelsystem, result of the continuing

More information

Instructions Manual Control Unit RCU205

Instructions Manual Control Unit RCU205 Instructions Manual Control Unit RCU205 1 / 8 Instructions Manual 2 / 8 1. Introduction RCU 205 RCU device main field application is the load limitation in elevators. The measurement accuracy is higher

More information

CO 2 gas Revert Recovery

CO 2 gas Revert Recovery CO 2 gas Revert Recovery ASCO CO 2 Gas Revert Recovery Systems ASCO CO 2 Gas Revert Recovery Systems are engineered to efficiently recover the revert CO 2 gas from ASCO Dry Ice Pellet and Block Machines

More information

( )

( ) (1-800-492-8826) OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels

More information

(770)

(770) (770) 345-0010 OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels

More information

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase) SRPH1 Series Single Phase, Analog Input Type SSR Features Power control/ Cycle control/phase control (fixed cycle/ variable cycle) are available with 4-mA analog input Superior dielectric strength : 4,000VAC

More information

Damper actuators with spring return

Damper actuators with spring return Damper s with spring return 4 Nm 4 Nm damper with spring return 8...16 mm Ø (round shaft), 8...12 mm (square shaft) Max. damper size 0.8 m 2 4 Nm 20 s, -20...+50 C, max. 60 s at -30 C Article Control signal

More information

Powerful Solutions for Welding and Cutting Automation with Precision and Versatility!

Powerful Solutions for Welding and Cutting Automation with Precision and Versatility! BUG-O SYSTEMS 280 Technology Drive Canonsburg, PA 15317 Phone: 412-331-1776 www.bugo.com Powerful Solutions for Welding and Cutting Automation with Precision and Versatility! The Modular Drive System is

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers This brochure provides a comprehensive overview of the applications and associated functions available with Rotork Q actuators - comprising Q Standard and Q Pak actuators. The watertight Q Range actuators

More information

Max. Input Power (W) Input Current v 2 2 0v 2 40v. Enclosure

Max. Input Power (W) Input Current v 2 2 0v 2 40v. Enclosure Output Power (W) Output Voltage (V) Output Current (A) Efficiency@ Max Load Max Case Temp. ( C) Input Current Max. Input Power (W) Inrush Current (Apk/50%-µs) THD @ Max Load (%) Power Factor @ Max Load

More information

Integrated Valve Assemblies FORAC

Integrated Valve Assemblies FORAC The F-Series + Integrated Valve Assemblies De-pressurised Pneumatics The single piston has only one dynamic sealing ring under pressure. This single seal has a short stroke thus minimising frictional wear.

More information

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM Complete Product Line A cost-effective solution for extending the life of batteries and reducing lift truck electrical problems

More information

BR Second Position Voltages. AA Fourth Position

BR Second Position Voltages. AA Fourth Position 1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V

More information

Lenntech. Lenntech SQ, SQ-N, SQE, SQE-N. Submersible pumps 50/60 Hz GRUNDFOS DATA BOOKLET. Tel.

Lenntech. Lenntech SQ, SQ-N, SQE, SQE-N. Submersible pumps 50/60 Hz GRUNDFOS DATA BOOKLET.  Tel. Lenntech GRUNDFOS DATA BOOKLET SQ, SQ-N, SQE, SQE-N Submersible pumps 50/60 Hz Lenntech info@lenntech.com info@lenntech.com Tel. Tel. +31-152-610-900 +31-152-610-900 www.lenntech.com www.lenntech.com Fax.

More information

ENNACTO 200 to Single acting hydraulic actuators with gas cartridge (Nitrogen) ENNACTO 200 to 1600: scotch -yoke kinematic

ENNACTO 200 to Single acting hydraulic actuators with gas cartridge (Nitrogen) ENNACTO 200 to 1600: scotch -yoke kinematic Type series booklet ENNACTO 200 to 12500 8560.11/4--10 Single acting hydraulic actuators with gas cartridge () ENNACTO 200 to 1600: scotch -yoke kinematic ENNACTO 3200 to 12500: Rod and crank kinematic

More information

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5 SGO Series SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 Ideal for Industrial, Analytical, and General Laboratory Applications SHEL LAB Gravity Convention Laboratory Ovens are recommended for

More information

Full 316SS design Up to 70,000Nm in DA! High Temp ** Low Temp ** No Painting or ENP coating required ISO mounting NAMUR VDI/VDE

Full 316SS design Up to 70,000Nm in DA! High Temp ** Low Temp ** No Painting or ENP coating required ISO mounting NAMUR VDI/VDE 1 Full 316SS design Up to 70,000Nm in DA! High Temp ** Low Temp ** No Painting or ENP coating required ISO mounting NAMUR VDI/VDE Mineral Processing Oil and Gas Petro-chemical Desalination Coal washery

More information

E J3-Series. Electric quarterturn / partturn actuators. ASC Armaturen GmbH - D Popelau

E J3-Series. Electric quarterturn / partturn actuators. ASC Armaturen GmbH - D Popelau E J-Series Electric quarterturn / partturn actuators ASC Armaturen GmbH - D 97 Popelau phone.: +49/884/68-0 Fax: +49/884/68- e-mail: info@ascarmaturen.de www.ascarmaturen.de ISO-Interface Optical function

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

ALUMINIUM TRACKS SYSTEM.

ALUMINIUM TRACKS SYSTEM. ALUMINIUM TRACKS SYSTEM www.utechinter.com www.facebook.com/utechinter CONTENTS Page General 3 UTA Aluminium Track System 4 Single girder suspension crane 4 Double girder suspension crane 5 Diagram for

More information

Damper Actuators Non-Spring Return

Damper Actuators Non-Spring Return 50 Non-Spring Return MD5A, MD10A, MD20A, MD40A The MD.A series are 2-10V modulating damper actuators designed for operating air control dampers in ventilation and air conditioning systems for building

More information

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor FlowX3 F3.20 is a paddlewheel flow sensor suitable for system at high pressure and at critical temperature. F3.20 is designed for use with every kind

More information

LARS. Leif Løken Rolls-Royce Marine Deck Machinery Seismic and Subsea

LARS. Leif Løken Rolls-Royce Marine Deck Machinery Seismic and Subsea LARS Leif Løken Rolls-Royce Marine Deck Machinery Seismic and Subsea 2010 Rolls-Royce plc The information in this document is the property of Rolls-Royce plc and may not be copied or communicated to a

More information

Trends in Digital Hydraulics

Trends in Digital Hydraulics Trends in Digital Hydraulics Matti Linjama Tampere University of Technology Introduction Motivation Trend I: Digital microhydraulics Trend II: Digital Hydraulic Hybrid Actuator Conclusions 14.4.2016 2

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

MANTSINEN. HybriLift. More load, less energy.

MANTSINEN. HybriLift. More load, less energy. 9 HybriLift More load, less energy. 9 HybriLift Lift your efficiency to the next level with hydraulic speed and precision. Uimaharju, Finland HybriLift Increases Energy Efficiency by up to Güllük, Turkey

More information

MANTSINEN. HybriLift. More load, less energy.

MANTSINEN. HybriLift. More load, less energy. 9 HybriLift More load, less energy. 9 HybriLift Lift your efficiency to the next level with hydraulic speed and precision. Antwerp, Belgium Uimaharju, Finland MANTSINEN HybriLift Increases Energy Efficiency

More information

DIRECTIONAL AND FLOW CONTROL VALVE WITH AMPLIFIER WITH DIGITAL SETTING UNIT (EHD3A SERIES) FEATURES APPLICATION EXAMPLES CAUTION

DIRECTIONAL AND FLOW CONTROL VALVE WITH AMPLIFIER WITH DIGITAL SETTING UNIT (EHD3A SERIES) FEATURES APPLICATION EXAMPLES CAUTION DIRECTIONAL AND FLOW CONTROL VALVE WITH AMPLIFIER WITH DIGITAL SETTING UNIT (EHD3A SERIES) CAUTIONS ON USE FEATURES 1. The valve enables easy 2-speed control and shockless control. 2. A digital setting

More information

Contents. Directional Control Valve 2 Series EPCV 452. Page 3. General Information. Page 4-5. Technical data. Page 6. Performance Curves.

Contents. Directional Control Valve 2 Series EPCV 452. Page 3. General Information. Page 4-5. Technical data. Page 6. Performance Curves. Contents Page 3 Page 4-5 Page 6 Page 7 Page 8 Page 9 General Information Technical data Performance Curves Dimensions : Hydraulic Valve and Accumulator Hydraulic Schematics Order Code Directional Control

More information

MANTSINEN. HybriLift. More load, less energy.

MANTSINEN. HybriLift. More load, less energy. 7 HybriLift More load, less energy. 7 HybriLift Lift your efficiency to the next level with hydraulic speed and precision. Nakhodka, Russia Aliağa, Turkey MANTSINEN HybriLift Increases Energy Efficiency

More information

Palletized Fixture Accessories

Palletized Fixture Accessories Frequently Asked Questions Some questions about pallet and tombstone clamping systems are common to both novices and experienced users. The answers to the following questions may help you better understand

More information