1 SIGRIST PIPE CHASE HOUSING by ALTA Products, LLC The original Drop-in solution for consolidating roof penetrations - 20 year warranty Medium Pipe Chase Housing is designed to accommodate up to 4 split systems (16 lines) Features: Standard color: Beige.080 thick aluminum housing and curb (Not fiberglass or molded plastic) UV protected powder coated finish (2mil thick) Stainless steel fasteners Full Thermal Break in the housing and curb Gasketed lid to housing and housing to curb connection points Two In-Stock sizes with other sizes available (Large and Data Center Systems) SMALL Data Center Pipe Chase Housing and curb system (Photo shows the housing during the installation process - the lid has been removed) Designed for small AC condensing units - Accommodates up to 7 Sigrist Exit Seals Housing #: AL x 10 x 12.5 tall Curb #: AL-158C 14.5 X 8 X 14 tall MEDIUM Sized to facilitate up to 4 split systems (up to 16 Sigrist Exit Seals can be installed) Housing #: AL x 14.5 X 12 tall Curb #: AL-1014C 18.5 X 12.5 X 14 tall Curb #: ALTC-M X 12.5 X 18 tall Curb #: ALTC-M X 12.5 X 24 tall We will gladly consider special sized systems - minimum quantity to make it economically practical is 5 unit Also featured in the photos are our Sigrist Exit Seals - ten line sizes:.25 up to 1.5 OD All Rights Reserved 2014 Copyright Alta Products, LLC Tel. (206) Stocking Distributor: Contractors Express, inc. Tel. (630)
2 Sigrist Exit Seal By ALTA Products, LLC Approaching 20,000 installed on commercial roofs from coast to coast Won t rust or oxidize or conduct cold and heat like metal Limited Lifetime Warranty Made in the United States of America Create a weather-tight pathway seal for roof penetration doghouses Injection molded UV inhibited resin to Schedule-80 strength Durable EDPM rubber gaskets 10 common pathway sizes (1/4 to 1 1/2 OD) Image to the left shows an actual installation using 4 Sigrist Exit Seals on our Sigrist Pipe Chase Housing and Curb system. May be used on existing and field fabricated housings. Sigrist Exit Seals can be used to create a weather-tight pathway through most every vertical wall with a smooth exterior. Maximum wall thickness is.75. We steadfastly manufacture all of our ALTA products in the United States of America. Many Sigrist Exit Seal uses: HVAC line sets Telecommunications Solar Power Sizing to Part Number Guide Molded from ultra high impact resin All Rights Reserved 2016 Copyright Alta Products, LLC Tel. (206) Contact Contractors Express, inc. Sales@Contractors-Express.com Tel. (630)
3 Installation Instructions Pipe Chase Housing Rev. B Pipe Chase Housing Step 1 - Roof Opening The roof opening size will be 2 narrower (width and length) than the ID opening of purchased Pipe Chase Housing curb. This will provide a 1 inch ledge around the inside of the curb to support the insulating and sound attenuating barrier. Step 2 - Setting The Curb Remove the stainless steel screws from the lid and inside the Pipe Chase Housing. Take care to place the screws in a secure place. Set the lid and housing aside for now. Center the curb over the hole and level. Use the appropriate size screw and quantity to attach the curb to the roof decking. Step 3 - Roofing Curb The curb has an insulated base and a built in 3 inch counter flashing to protect the leading edge of the roof. Run the roofing to the top edge of the curb taking care not to cover the screw holes on top. The gasket in the bottom of the Pipe Chase Housing is designed to be wide enough to seal off against the top of the curb and leading edge of the roof at the same time. There is a 3/4 clearance around the curb for roofing. If you exceed this thickness the Pipe Chase Housing will not slide over the top of the curb. Step 4 - Housing Place Pipe Chase Housing back on the curb and attach with stainless steel screws. The Pipe Chase Housing is designed to counter flash the curb with a 3 inch skirt. The housing gasket will seal against the top of the curb and leading edge of the roof. The outside walls of the Pipe Chase Housing have dimples and bumps. The dimples identify the locations to drill holes to install Exit Seals. The bumps identify the boundary of the penetration area. The bumps define the field for penetration and prevent you from drilling too close to the skirt and corners of the housing. Exit Seal are designed to be used with the Pipe Chase Housing to provide the best weather tight seal around the pipes passing through the Pipe Chase Housing wall. The dimples are offset on opposite sides to prevent pipes from colliding inside the housing. This dimple pattern maximizes the number of pipes that can penetrate the Pipe Chase Housing. This is a Pipe Chase Housing With Sigrist Exit Seals properly installed Top view of the Pipe Chase Housing with the lid removed with 16 Sigrist Exit Seals installed Contractors Express, inc. Tel. (630) Sales@Contractors-Express.com All Rights Reserved 2015 Alta Products, LLC
4 Installation Instructions: Sigrist EXIT SEAL Sigrist Exit Seal Each Sigrist Exit Seal is designed to work on a range of pipe sizes. There are 10 Sigrist Exit Seal sizes to cover commonly used pipe, line and cable sizes (1/4 through 1 1/2 OD). Each Sigrist Exit Seal range is in 1/8 inch increments. For example, the smallest Sigrist Exit Seal has a range from 1/4 to 3/8. Pipe sizes that fall on or between 1/4 to 3/8 will fit this Sigrist Exit Seal. This is true for all 10 Sigrist Exit Seal sizes offered. Step 1. Locate the Starter Dimple on either side of the Pipe Chase Housing. Note: if you are going to populate a double row of Sigrist Exit Seals, always start the plumbing or line setting on the lower row first) Step 2. Drill or punch a 2.25 diameter hole where desired Step 3. Clear the lose debris/ filings and insulation from the hole area Step 4. Unthread and remove the backing nut from the Sigrist Exit Seal body leaving the backing nut gasket on the body then insert the body into the 2.25 dia hole. Step 5. Thread the backing nut onto the Sigrist Exit Seal body to strong finger tightness. Do not wrench tighten the nut. Step 6. Piping - After the Sigrist Exit Seals are installed in the Pipe Chase Housing you are ready to run the piping. You can run any pipe size between 1/4 inch out side diameter to 1 1/2 (out side diameter). Sigrist Exit Seals are molded from highimpact resin with EPDM rubber gaskets and can be damaged if exposed to high heat from brazing or soldering during the piping process unless precautions are taken to reduce the exposure to open flame and extreme temperatures. Move the Exit Seal down the pipe and wrap with a wet cloth to protect them. WARNING: Sigrist Exit Seals are not designed to be water fittings and should never be used as a fitting in a water system. You can run water lines through an Exit Seal but Exit Seals are not designed to contain pressurized liquids or gasses. Contractors Express, inc. Tel. (630) Sales@Contractors-Express.com All Rights Reserved 2016 Alta Products, LLC
5 2016 CONTRACTOR - SIGRIST PIPE CHASE HOUSING/EXIT SEAL ORDER FORM Contractors Express, inc S. Madison, Willowbrook, IL Tel PO Number: Job Name: Date of order: SOLD TO: Company: Mailing address: City, State & Zip: Orders to: Sales@Contractors-Express.com Contact person: Telephone: Company: Street address: City, State & Zip: Contact person: SHIP TO: Telephone: Pipe Chase Housings Required delivery date: Please specify delivery speed: UPS Ground UPS 3-Day UPS 2nd-Day UPS Next Day Is the a loading dock? Is there a fork lift? (All Curbs are standard 14" tall) Order Quantity Part Number Description Size (Inches) LxWxH Unit Price Total AL SMALL - Pipe Chase Housing 16.5 x 10 x 12.5" $ - AL-158C SMALL - Curb 14" tall 14.5 x 8 x 14" $ - AL MEDIUM - Pipe Chase Housing 20.5 x 14.5 x 13.5" $ - AL-1014C MEDIUM - Curb 14" tall 18.5 x 12.5 x 14" $ - ALTC-M18 MEDIUM - Curb 18" tall 18.5 x 12.5 x 18" $ - ALTC-M24 MEDIUM - Curb 24" tall 18.5 x 12.5 x 24" $ - *AL LARGE - Pipe Chase Housing 34 X 34 X 24" $ - *AL C LARGE - Curb (included with housing) 32 x 32 x 14" $ - $ - Sigrist EXIT SEAL - See Sizing Chart to select proper cap size Sub: $ - Part Number Description Cap size pathway dia. Unit Price Total 2025 Exit Seal (body and cap) 1/4" - 3/8" $ Exit Seal (body and cap) 3/8" - 1/2" $ Exit Seal (body and cap) 1/2" - 5/8" $ Exit Seal (body and cap) 5/8" - 3/4" $ Exit Seal (body and cap) 3/4" - 7/8" $ Exit Seal (body and cap) 7/8" - 1" $ Exit Seal (body and cap) 1" - 1 1/8" $ Exit Seal (body and cap) 1 1/8" - 1 1/4" $ Exit Seal (body and cap) 1 1/4" - 1 3/8" $ Exit Seal (body and cap) 1 3/8" - 1 1/2" $ Cap only Cap $ - HS-225 Hole Saw with Mandrel - Metal cutting 2.25" Dia. $ - 0 Total Seals Sub: $ - IMPORTANT NOTES: Prices are FOB the factory - Estimate 10% of the sale amount for freight Items total: $ - 25% restocking fee for all standard items - RMA IS REQUIRED Est. Freight: $ - 3% transaction fee for credit cards - Custom or non-stocked items are not returnable Grand total: $ - Ordered by: * This is a non-stocked item - production lead time is up to 6 weeks
SHELVING PRODUCTS. Maximize Your Storage Space
SHELVING PRODUCTS Maximize Your Storage Space SHELVING UNITS Pre-engineered sections are 36, 42, and 48 wide and 84, 96 and 120 high, with shelves adjustable on 1-1/2 centers. For double row, back-to-back
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationRoof Hatches Smoke Vents /BAB BuyLine 0898
Roof Hatches Smoke Vents 07 72 00/BAB BuyLine 0898 Roof Hatches: Steel & Aluminum Ladder Access Ship Stair Access Designed for fixed ladder roof access 30 x 30 36 x 30 36 x 36 Designed for ship stair roof
More informationThe TeleControl Series Technical Drawings
The TeleControl Series Technical Drawings TeleControl TeleControl Enclosures Dimensions SIZE ID NUMBER OVERALL H X W X D INSIDE A X B X C E X F J K L M N HOLE DIA. SHIPPING WEIGHT PANEL NUMBER J1407TC
More information5830 Skylight, Solar Smart Retrofit Installation
Introduction The Solar Smart has a mounting bracket that allows the operator to rotate slightly to reduce wear and tear on the chain drive system for greater performance and reliability. Because of this
More informationA century of Excellence... a legacy of Quality
85" igh with Shelves Take advantage of your existing vertical space and save substantially by installing a Republic shelving mezzanine system. 10 Shelves 9 Openings 8 Shelves 14 Openings D Capacity 36"
More informationModel # 358-OPR-GT. 4/15/2015 Page 1 of 12
Model # 358-OPR-GT /15/2015 Page 1 of 12 /15/2015 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationSAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT
SAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT C A R L I S L E D R Y L I G H T Innovation, Expertise and Stability For more than 45 years, Carlisle SynTec has been a leader in the commercial roofi
More informationFord Fabricated Steel Products
Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas
More informationWALL MOUNTING KIT ASSEMBLY INSTRUCTIONS MODELS: TXBW & TXDW
Wall Opening Wall Mounting Adaptor (Optional) Support Strap E WALL MOUNTING KIT ASSEMBLY INSTRUTIONS MODELS: TXBW & TXDW The centrifugal power roof ventilators model TXB (belt drive) and TXD (direct drive)
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More informationHolley Ford 351W Hi-Ram Modular Intake Manifold Kits
Holley Ford 351W Hi-Ram Modular Intake Manifold Kits Holley P/N Engine Application & Induction Configuration 300-241 Hi-Ram, 1 x 95mm LS Throttle Body (longitudinal mount) w/ port EFI provisions & fuel
More informationIMPORTANT OWNER- OPERATOR INSTALLATION INSTRUCTIONS A7706R / A7708R - A7711R / A7712R A7706RS / A7708RS - A7711RS / A7712RS
IMPORTANT OWNER- OPERATOR INSTALLATION INSTRUCTIONS A7706R / A7708R - A7711R / A7712R A7706RS / A7708RS - A7711RS / A7712RS Warning!! This battery box is made of aluminum and is Conductive! Do not allow
More informationROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES!
ROOF HATCHES SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES! Over 45 years of proven performance in Standard & Custom Designed Hatches ROOF HATCHES Better by design LEXCOR COMPANY PROFILE Lexcor was incorporated
More informationFREEDOM4. Portable Restroom Assembly Instructions
FREEDOM4 Portable Restroom Assembly Instructions 2530 Xenium Lane North, Minneapolis, MN 55441 Telephone: 763-553-1900 Fax: 763-553-1905 800-328-3332 / www.satelliteindustries.com 9/18 REVD 22541 INSTRUCTION,
More information10-year installation warranty. VELUX flashing required to qualify
Curb mounted skylights 10-year installation warranty. VELUX flashing required to qualify The No Leak Skylight No Leak Promise No Worries 1 2 3 1 3 2 3 layers of water protection for curb mounted skylights
More informationISO 9001:2008
DOOR Dutch, Heavy Duty, Individual Dog Model Features 1 FREEMAN MARINE Dutch doors perform like a single panel door when regular access is needed, yet the top half can be operated separately from the bottom
More informationPACIFICA Shower Cabin Installation Instructions
PACIFICA Shower Cabin Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower cabin. If you have any questions on this shower cabin installation
More informationVAN STORAGE SOLUTIONS FOR THE WAY YOU WORK
WWW.WEATHERGUARD.COM VAN STORAGE SOLUTIONS FOR THE WAY YOU WORK Weather Guard / KNAACK 420 E. Terra Cotta Ave. Crystal Lake, IL 60014 USA 800-456-7865 (Toll Free) 800-334-2981 (Fax) Knaack.OrderEntry@wernerco,.com
More informationSafety Grating DIAMOND-GRIP PRODUCT DESCRIPTION FEATURES & BENEFITS MATERIAL SPECIFICATIONS. Note:
DIAMOND-GRIP PRODUCT DESCRIPTION Diamond-Grip is a one-piece metal plank grating manufactured by a cold forming process in the shape of a channel. The web of the channel is the walking surface and has
More informationSelection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &
More informationLOWE Industries. SBF Cleveland Chain Fuel Pump Drive Kit Front Engine Plate
LOWE Industries PO Box 180 Rosewood, Qld 4340 Australia www.kenlowe.com.au Phone 0411-699 535 SBF Cleveland Chain Fuel Pump Drive Kit Front Engine Plate 351C Ford Cleveland Front plate only but plate has
More informationDurulite Door Hardware Manual
R Durulite Door Hardware Manual World s Leading Manufacturer Of Traffic Doors Cincinnati, Ohio and Redmond, Oregon Phone: 1-800-543-4455 FAX: 1-800-245-7045 Www.chasedoors.com TABLE OF CONTENTS DESCRIPTION
More information255 Cartridge Dual Seal
MECHANICAL SEAL INSTALLATION INSTRUCTIONS 255 Cartridge Dual Seal Installation Instructions SEAL INSTALLATION Preparation Determine if the pump is in good condition. A. Check the shaft or sleeve. 1. Remove
More informationLPE C5 Battery Relocation Kit
LPE C5 Battery Relocation Kit The LPE C5 Corvette battery relocation kit improves vehicle weight distribution by moving weight to the rear of the vehicle. The improved weight distribution increases traction
More informationD-4070 Two Stage Pneumatic Actuator
FANs 268.1, 1628.3 Product/Techncial Bulletin D4070 Issue Date 1095 D-4070 Two Stage Pneumatic Actuator The D-4070 Two Stage Pneumatic Actuator is a multipurpose positioning device used to accurately position
More informationTURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)
TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with
More informationSPYDER SPORTS SALES PART # POR = PRICE ON REQUEST PRICE. POR exact copy) in aluminum with mounting weld nuts 550R MIRROR HOUSING GASKET POR
SPYDER STS SALES Two 550-A Spyders restored by Spyder Sports, racing at the Grand Prix de Monte Carlo. SPYDER REPLICAS For fine replicas of Beck & vintage cars. All parts are copied in exact detail. PART
More informationINSTALLATION INSTRUCTIONS Part# , , ,
INSTALLATION INSTRUCTIONS Part# 20-0218, 22-0318, 20-0118, 22-0219 20-0218 - 4 Tire On Board Air Delivery System and Dual Compressed Air System Includes ARB CKMTA12 Compressor 20-0118 - 2017 FORD RAPTOR
More informationEXPANSION SEAL TECHNOLOGIES DC /01 REV 2 06/05 PAGE 1 OF 4
EXPANSION SEAL TECHNOLOGIES DC9567 11/01 REV 2 06/05 PAGE 1 OF 4 OPERATING PROCEDURES FOR GRIPTIGHT HIGH PRESSURE TEST PLUGS WITH ALTERNATE SEAL MATERIALS Description: GripTight plugs supplied with alternate
More informationMicroSpan. Chain. Chain. revised SpanTech LLC
Chain MicroSpan Chain 1 27 SpanTech LLC Contents Overview... 3 MicroSpan Chain Types... 3 The Nose Bar... 6 Chain Fabrication... 8 Chain Widths... 8 MicroSpan Sprockets... 9 Standard Split Sprocket...
More informationSTEERING COLUMN, LOWER STEERING SHAFT, AND STEERING GEAR BOX ALIGNMENT
Please note: this is a draft document it has not been validated. If you choose to use it please check all steps and, if you find something wrong or have suggestions, contact Rob Mueller. This was presented
More informationTrail Rocker Installation
Trail Rocker Installation Instructions Customizable Trail Rocker Control System For Installing Painless Part Number: 57100 Manual #90616 Painless Performance Products recommends you, the installer, read
More informationVibra-Proof Condenser Plugs. The Condenser Plugs That Won t Vibrate Loose.
Vibra-Proof Condenser Plugs The Condenser Plugs That Won t Vibrate Loose. Vibra Proof Condenser Plugs CPI Plugs Perma Plugs P2 High Pressure Plugs Ram Packages Tube Stabilizers Manual Installation Tools
More informationSECTION PLASTIC SHUTTERS AND ACCESSORIES. Copyright 2016 The Tapco Group
SECTION 06 60 00 06470 PLASTIC SHUTTERS AND ACCESSORIES Copyright 2016 The Tapco Group PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior shutters. B. Exterior shutter hardware. C. Arch tops. D. Transom tops.
More informationModel DW Series Positive Pressure Guidelines for Engine Exhaust Systems
1 Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems UL Listed under Standard 103 for Flue Gas Temperatures up to 1400 F (759 C) Venting System for Factory-Built Chimneys For Building
More informationINSTALLATION, OPERATION + MAINTENANCE
INSTALLATION, OPERATION + MAINTENANCE Smoke Vents OVERVIEW Smoke vents are designed to open automatically to provide emergency smoke and heat ventilation. Prompt venting in case of fire is essential for
More informationTrack Rocker Installation Instructions
Track Rocker Installation Instructions For Installing Painless Part Numbers: 58103: 8-Switch Customizable Track Rocker Switch Panel w/ Flanged Mount 58106: 6-Switch Customizable Track Rocker Switch Panel
More informationSERIES G603 STANDARD FRONT MOUNT GAGE
LIQUID LEVEL GAGE -FRONT MOUNT, FLEXIBLE, CLEAR Economical, versatile and durably constructed. Available in mounting lengths to 600 inches (15240mm). Practical where oil level readings are necessary on
More informationAutomatic Roof Door Vents
DATA SHEET Automatic Roof Door Vents Features n UL Listed for use as an automatic smoke vent n FM Approved as an automatic door vent for use in high expansion foam systems n Available in multiple sizes
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationSANITIZERS COMMERCIAL AQUATICS ADA-COMPLIANT LIFTS
SANITIZERS COMMERCIAL AQUATICS ADA-COMPLIANT LIFTS 140 ADA-COMPLIANT LIFTS 141 ADA-COMPLIANT LIFTS AquaTRAM 90 AQUATRAM POOL ACCESS LIFTS ADA-COMPLIANT COMMERCIAL POOL LIFTS AquaTRAM LT AquaTRAM Featured
More informationSolarSheat Wall Installation Manual
SolarSheat Wall Installation Manual Version 1.5 April 23, 2013 Copyright 2013 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing, electrical,
More informationSAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.
SAFETY Your safety and the safety of others is very important. In order to help you make informed decisions about safety, we have provided installation instructions and other information. These instructions
More informationSafePro N Walton Walker Blvd, Dallas, TX (877)
SafePro 1355 N Walton Walker Blvd, Dallas, TX 75211 www.safeprosafety.com (877) 723-3570 Roof Hatch Safety Rails U.S. patent number 8,726,577 SafePro Roof Hatch Safety Rails are a patented 4-Sided Rail
More informationGravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief
Gravity Ventilators Models FGI and FGR Fabra Hood Intake and Relief July 008 Page Fabra Header Hood Greenheck Fabra Hoods are designed for intake (Model FGI) or relief (Model FGR) applications with either
More informationUSE, CARE & STERILIZATION INSTRUCTIONS. Consumable Accessories Burs Saw Blades K-Wires Steinmann Pins Twist Drills Rasps Ortho Pins/Drills Guide Wires
USE, CARE & STERILIZATION INSTRUCTIONS Consumable Accessories Burs Saw Blades K-Wires Steinmann Pins Twist Drills Rasps Ortho Pins/Drills Guide Wires Rx Only EXPLANATION OF SYMBOLS 2 g h i N B D L M d
More informationCommercial Hopper Tanks (CHT)
Commercial Hopper Tanks (CHT) Total Value. Total Systems. NCHT & FCHT Series The right tank for the right job. Commercial hopper tanks are typically used in applications where routine clean out is required,
More informationHATCHGRIP Installation Instructions/Operation and Maintenance Manual
HATCHGRIP Installation Instructions/Operation and Maintenance Manual Models: HTG-PCG Contact Information Table of Contents: Safety Precautions... 2 Product Information... 2 Operation... 3 Installation
More informationExam Room Group (shown) 8010 (reversed) W: 43", 46", 49" H : Wall: 30", Desk: 30" D : Wall: 14.25", Desk: 24.25" Cabinet group consists of:
Exam Room Group Exam Room Group 8008 W: 29" - 50" (3" increments) H : Wall: 8", Desk: 30" D : Wall: 13.25", Desk: 24.25" #3020 wall mounted book shelf (27" - 48" W) #1500-4.5" knee space drawer (27" -
More informationModel 377, 379, 386, 388, Sleeper no window
Installation Manual Model 377, 379, 386, 388, 389 63 Sleeper no window 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 NITE Plus Installation Procedures 1-2 Table
More informationInstallation Instructions
Instructions Created by an: Inchworm Tacoma Dual Case Adapter Installation Instructions Suggested Tools: CAUTION: Safety glasses should be worn at all times when working with vehicles and related tools
More informationTU-WAY ROOF VENTILATORS
BULLETIN 615 December 2000 TU-WAY ROOF VENTILATORS Tu-WAY Roof Ventilators Aerovent has provided quality air moving and ventilation equipment for over sixty-five years and is a recognized leader in this
More informationALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)
ALVARADO EDCX Bullnose Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.5 (1029 mm) 25 (635 mm) 36.5 (927.1 mm) Materials Cabinet: Formed and welded 14 gauge
More informationModel 1065 Dual Drive Winch System. *For Installation On. drywall lift model 439
by OPERATOR S MANUAL Model 1065 Dual Drive Winch System *For Installation On drywall lift model 439 *This Drill Drive TM Winch System is designed to be compatible with Genuine PANELLIFT Brand Drywall Lift
More informationInstructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationInstallation Instructions I - Sheet Number I-TVR-01 Rev. A
Installation Instructions I - Sheet Number I-TVR-01 Rev. A TrailView Soft Top For proper installation and best possible fit, please read all instructions BEFORE you begin. For technical assistance or to
More informationUPDATED v3.0. Cargo Van Racks & Interior Equipment GMC/CHEVY 2016 PRODUCTS CATALOG
UPDATED 4.30.16 v3.0 Cargo Van Racks & Interior Equipment GMC/CHEVY 2016 PRODUCTS CATALOG WWW.KARGOMASTER.COM 800-343-7486 Chevy City Express Steel Van Packages Compact Cargo Vans Commercial Shelving Part
More informationModel # TR-32-RT. 4/29/2015 Page 1 of 9
Model # TR-32-RT 4/29/2015 Page 1 of 9 /29/2015 Page 2 of 9 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationINSTALLATION INSTRUCTIONS FOR PLEASE READ AND UNDERSTAND TERMS/POLICIES BEFORE YOU INSTALL THIS SYSTEM
MOUNTAIN OFF ROAD ENTERPRISES. LLC. P.O. BOX 690 DELTA, COLORADO 81416 970-625-0500 E-mail: info@mountainoffroad.com www.mountainoffroad.com INSTALLATION INSTRUCTIONS FOR 8795-2 PLEASE READ AND UNDERSTAND
More informationPickup Truck Rack. Installation instructions for Ford - Chevy - Ram
Installation instructions for Pickup Truck Rack Ford - Chevy - Ram MyGlassTruck.com 200 Acorn Road LOCAL 856-595-9069 WEB www.myglasstruck.com Glassboro, NJ 08028 FAX 856-863-1480 1-844-364-4022 Version
More informationExceeding Your Expectations Through Superior Workmanship and Design
Quality Since 1974 Exceeding Your Expectations Through Superior Workmanship and Design Model AL40120V-BB/ AL50120V-BB Lift shown with Full-Length V-Bunk. Lift shown with Hemlock Tweed SeaMark fabric canopy.
More informationHP10207 KIT. Ram WD*
HP10207 KIT Ram 1500 4WD* (For 2WD call customer service 800.663.0096 for assistance) * See application guide for proper fitment. Use the most advanced air springs on the market to eliminate your vehicle
More informationINSTRUCTION MANUAL # FiTech Hy-Fuel Tight-Fit In-Tank Retrofit Kit
FiTech Fuel Injection INSTRUCTION MANUAL #40015 - FiTech Hy-Fuel Tight-Fit In-Tank Retrofit Kit NOTE: This Hy-Fuel In-Tank Kit can be used with any EFI system, or with the proper low pressure bypass style
More informationGlobal Finishing Solutions Table of Contents
Global Finishing Solutions Table of Contents Spray Booths-Accessories ProClean - Open Face Filter Booths... 2 ProClean Extensions... 3 Redi-Pak TM - Bench Booths... 4 Ultra and Concept Paint Mix Rooms...
More informationBRUTE FORCE AIR INTAKE SYSTEM
BRUTE FORCE AIR INTAKE SYSTEM Equipped with AEM DRYFLOW Filter. No oil required! Installation Instructions for: Part Number 21-8306 2005 Jeep Grand Cherokee 2006 Jeep Commander 5.7L V8 HEMI ADVANCED ENGINE
More informationENLIGHTENED LIVING RESIDENTIAL SKYLIGHTS E-CLASS CURB-MOUNT ARCHITECTURAL SERIES
ENLIGHTENED LIVING RESIDENTIAL SKYLIGHTS E-CLASS CURB-MOUNT ARCHITECTURAL SERIES RESIDENTIAL SKYLIGHTS A NEW LEVEL OF PROFESSIONAL QUALITY FOR THE HOME At Wasco, we know what builders and their customers
More informationModel DW Series Positive Pressure Guidelines for Engine Exhaust Systems
Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems UL Listed Under: UL 103 / ULC ORD C959 UL 2561 / ULC ORD C959 UL 641 / ULC S609 1 Please note these instructions cover the additional
More informationModel # PR-32RE. 11/5/2014 Page 1 of 10
Model # PR-32RE 11/5/2014 Page 1 of 10 1/5/2014 Page 2 of 10 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationPLASTIC BIN SUPPORT RACKS
PLASTIC BIN SUPPORT RACKS Louvered bin panels can be wall-mounted, attached to back of shelving, mounted on benches, carts, inside cabinets, fastened to slotted angle components or used for service truck
More informationGEN 3 LED LIGHT BAR INSTALLATION MANUAL Model 7840-A 44"
GEN 3 LED LIGHT BAR INSTALLATION MANUAL Model 7840-A 44" Your purchase of a Wolo warning light bar is the perfect choice to compliment your vehicle. Wolo s warning lights are manufactured with the finest
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationSAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.
SAFETY Your safety and the safety of others is very important. In order to help you make informed decisions about safety, we have provided installation instructions and other information. These instructions
More information2018 RAV4 AWD XLE Accessories
March 22, 2018 Ontario Towing Hitch (2" Receiver), Ball Platform & Wire Harness $1,573.50 This Towing Hitch system is specifically manufactured for the RAV4, and has been engineered to obtain the vehicle's
More informationInstructions for 2-row monitoring only
Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only CAUTION: Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect
More informationEXPRESS ASSEMBLY MANUAL SECTION 3 F5-RG/FT WING ASSEMBLY. Procedure 3.050A INSTALLATION OF AILERON TORQUE TUBE ASSEMBLY
Procedure 3.050A INSTALLATION OF AILERON TORQUE TUBE ASSEMBLY In this procedure The aileron torque tube will be assembled and installed in the wing. Part Number Description Quantity 111-24-050 Torque Tube,
More information(1032 mm) 30.5 (775 mm) 44 ( mm)
ALVARADO EDCX-EK Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.625 (1032 mm) 30.5 (775 mm) 44 (1117.6 mm) Materials Cabinet: Formed and welded 14 gauge
More informationRBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL
RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated
More informationTHE VALUE CAP WITH YOUR NEEDS IN MIND.
ECHO VALUE CAB-HI THE VALUE CAP WITH YOUR NEEDS IN MIND. If you are looking for a basic cap that looks great then the Ranch Echo is the perfect fit for you. Designed to help secure and seal your truck
More informationSaf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent
Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall AL 29-4C Stainless Steel Special Gas Vent 130 Industrial Boulevard Turners Falls, MA 01376 Copyright 2001 Heat-fab, Incorporated Saf-T Vent
More informationINSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS
INSULATED ANTED ROOF URB NON-PROPELLER PRODUTS Wood Nailer A 3" 3/4" 3" 1" Semi-Rigid Insulation Damper Shelf (Optional) (1) B OPTIONS: 1. Damper Shelf. 2. Metal Liner - solid or screen type. 3. Burglar
More informationShipping and Receiving
This chapter describes the issues to consider as you prepare to receive shipment of the Cisco CRS Carrier Routing System 16-Slot Line Card Chassis and transport the chassis components to the installation
More informationINSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS
INSULATED ANTED ROOF URB NON-PROPELLER PRODUTS Wood Nailer A OPTIONS: 1. Damper Shelf. 2. Metal Liner - solid or screen type. 3. Burglar bars - 1/2" dia. on 6" centers. 4. Finishes - baked or air-dried
More informationInstructions for 2-row monitoring only
Installation Instructions for CaseIH cotton picker models: Instructions for 2-row monitoring only Ensure the model numbers shown above correspond to the machine model. If you receive the incorrect installation
More informationIn Stock superabrasive tooling EXPRESS LINE.
In Stock superabrasive tooling EXPRESS LINE www.abrasive-tech.com INTRODUCTION Welcome to Abrasive Technology s Express Line Catalog This catalog is a listing of standard products that we carry in stock
More informationThermocouples W A T L O W
W A T L O W Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions of thermocouples for
More informationINSTRUCTION MANUAL: Industrial Series Piston Air Compressor. Model Number: V Part Number: L001128KNA
INSTRUCTION MANUAL: Industrial Series Piston Air Compressor Model Number: V8051-335 Part Number: L001128KNA Pump Model: LP335 K335 Motor: 5 HP / 1 PH Air Tank: 80 Gal Vertical 1830 W. 15 th St. Houston,
More informationWINCH MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL. Application WINCH KIT NO. 25-9xxx
WINCH MOUNT KIT FOR POLARIS RANGER P/N 25-3370 ASSEMBLY / OWNERS MANUAL Application WINCH KIT NO. 25-9xxx Before you begin, please read these instructions and check to be sure all parts and tools are accounted
More informationRead all instructions carefully before attempting installation. REV DSL
Corporate Office: PerTronix Inc. 440 E. Arrow Highway, San Dimas, California 91773 * Phone 909.599.5955 FAX 909.599.6424 Installation Instructions And Warranty Information Part # 6830S ~ Small Block Chevrolet
More informationULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE
Shown with ILS OPTION (Internal Bracket/Light Shield) Kit ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE Remote version shown Models: UMX-1224T/ UMX-1924T / UMX-12242T / UMX-19242T 24v Power Input with
More informationWhen Time is Everything... We Manufacture in Days - Not Weeks!
When Time is Everything... We Manufacture in Days - Not Weeks! DAMPERS ACCESS DOORS LOUVERS July 2014 Specializing In Products For The HVAC Industry 763-783-7173 fax: 763-785-6977 1-800-297-9360 Customer:
More informationIf you have any difficulties at all, please give us a call. Thank you and enjoy your MetalCloak Products!
PRODUCT: TJ/LJ 3.5 Dual Rate Lift RockSport Edition READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL 916-631-8071 M-F 7:00 AM 5:00 PM PST The MetalCloak experience includes the ease of installation
More informationInstallation Instructions
Contents Page General Information and Installer Tips.......... 2 Panels & Posts............................. 3 Enclosure Description..................... 4 Hinge Door Hardware................... 4-5 Step-by-Step
More informationThe Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB
The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators
More information4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology
4.0 RAIL-FREE RACKING Utilizes EcoFasten Solar s patented technology Document Date: 3.2.2018 Contents Pg. 1 Assets of Design Features System Components Pg. 2 Rock-It 4.0 Mount Assembly Rock-It 4.0 Coupling
More informationGROUNDING & BONDING PRODUCTS
GROUNDING & BONDING PRODUCTS Busbars Page 5-3 Insulators Page 5-8 Grounding Products Page 5-9 Compression Tools, Lugs & Taps Page 5-14 Learn About CPI s Extended Limited Warranties for coverage of (2)
More informationAluminum Railing. Strong, Durable and Maintenance-Free Beauty! Meets OSHA, ADA and ICC Safety Criteria SERIES
Aluminum Railing Meets OSHA, ADA and ICC Safety Criteria 000 00 Strong, Durable and Maintenance-Free Beauty! www.superioraluminum.com Strong, Durable, and Maintenance-Free Beauty! Superior Series 000 and
More informationClipper Defined. Shelving. Clipper Hi-Performance Shelving Systems. Growth with. Penco Hi-Performance Shelves. Growth with
Defined Clipper Hi-Performance Systems At the heart of the Clipper System is the ingenious Penco Clipper Clip. It is easily installed, holds the shelf firmly in place, can be repositioned at any time,
More informationSEACO. Backed By The Industry's Only 15-Year Warranty
The Industry's Only 15-Year Warranty Seaco/Ace floating dock floats are available in standard, large and boatlift configurations providing buoyancy ratings from 230lbs. to 4,62lbs. Over sixty-five (65)
More informationModel ND-2 Specification
Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction
More information