UPSaver 20012,800KW. Efficiency. Scalability. Product Highlights

Size: px
Start display at page:

Download "UPSaver 20012,800KW. Efficiency. Scalability. Product Highlights"

Transcription

1 20012,KW UPSaver Efficiency. Scalability. Product Highlights Certified efficiency up to 99.5 Modular and scalable up to 12.8MW True on-line double conversion UPS Smart Energy Management Green Conversion Technology High Power Density Low Carbon Footprint

2 The UPSaver Philosophy The flexibility of the system is achieved by using power modules, which can configure both stand-alone units and modular systems. From Uninterruptible Power Supply to Uninterruptible Power Saver, a permanent saving system continuously monitoring the mains to guarantee high quality power to your ICT equipment at minimum energy usage Certified Efficiency Saving energy is one of the main focuses in the data centre industry, due to rising energy bills and environmental constraints. Improving a data centre PUE (Power Usage Effectiveness) is therefore a target for owners and managers, whilst being flexible to cope with such a fast changing market. Regarding UPS, all these needs must translate into: - High efficiency - Modularity - Low total cost of ownership Since the early stage of involvement in designing and building, AVK has beencommitted to fulfilling the needs and developing innovative customised technologies for high efficiency power supply solutions dedicated to ICT UPSaver UPSaver is a complete, very high efficiency, multi-function and fully adaptable power protection system.

3 Modularity and Scalability Removable power modules for easy maintenance and 200KW Scalable. Modular. Futureproof. Configuration The system is based on 100 or 200 kw power modules (named Basic Power Unit: BPU) that can be configured either as stand-alone units or as modular systems. A stand-alone unit, named Fixed Power Unit (FPU), is formed by a BPU, circuit breakers and the control logic, while a modular system, named Growing Power Unit (GPU), is formed by N BPU modules and an I/O module Smart-parallel function continuously monitors load power requirements and maximises system efficiency by turning off all unnecessary power modules. CPM (Current Parallel Mode) ensures reliable and efficient expansion up to full power, totally eliminating circulating currents between UPS. 12,KW UPSaver Unit modularity for flexible and fast power expansion System modularity allows your businesses power to grow up to more than 12MW

4 The Modular Format Power Module (BPU) features: Removable power sub-modules Hot connection and self-diagnosis High power density (0.58 m2/200 kw) I/O Module features: Rectifier, static bypass, maintenance bypass and output main disconnectors Rectifier, output and battery module disconnectors Static bypass module contactor Top and bottom cable entry 10 touch screen display UPSaver

5 Modes of Operation UPSaver

6 Inside the Technology AVK s innovative technologies maximise environmental sustainability and minimise TCO (Total Cost of Ownership) in ICT dedicated UPS. AVK s advantage technology and battery control techniques AVK s Advantage Technology is based on a patented control algorithm, managing the battery-inverter subsystem in order to enhance double conversion efficiency and extend battery life. When a battery is charged and the mains are stable, it is protected from the DC-link ripple by a solid state dynamic battery switch UHE TECHNOLOGY FOR MAXIMUM EFFICIENCY Advantage inverter control enhances system efficiency by reducing IGBTs commutation losses. During mains outages, Advantage controls the dynamic battery switch SCRs and the battery feeds the inverter Ultra High Efficiency (UHE) technology is the AVK off-line mode. Based on a sophisticated control technique, in UHE mode efficiency is achieved, whilst protecting ICT loads from power quality loss. UHE mode of operation protects Critical loads by monitoring mains power quality while feeding them via the static bypass line. Rectifier and inverter are in deep standby G UPSaver Thanks to its high energy efficiency solutions and the reduction of maintenance costs, AVK is proving to be the ideal partner wherever PUE reduction is a primary goal.

7 Ultra HIGH Efficiency on-line mode G Y Ultra HIGH Efficiency on-line mode U l t r a H i g h High Efficiency interactive mode (VHE): If input mains stability and reliability is outside pre-set limits, this mode of operation is activated. Loads are fed by the mains and the inverter is turned on and off by the control logic to stabilise UPS output and the rectifier keeps full battery capacity. That s what we call Very High Efficiency (VHE) mode. Efficiency is 97, due to the transient inverter and rectifier contribution to overall losses E f f i c i e n c y n o ICT loads have to have a grade of r G m immunity to power disturbances Y a to be compliant with EMC l international standards and U product development guidelines l m (i.e. ITIC/CBEMA curve). AVK s t o UHE technology protects ICT r d loads by monitoring mains a e quality, enabling on-line operation whenever H o disturbances approach load i f g of immunity limits. The maximum h o system efficiency is thus achieved p taking advantage of ICT loads E e built-in immunity to power quality f r issues, whilst ensuring them the f a protection they actually need. i c t i UPSaver Ultra High Efficeincy on-line mode describes the way the logic controls the inverter to feed power to critical loads

8 TECHNICAL DATA SHEET: General Information UPSaver kVA3Ph(in) 3Ph(out) POWER kva 600 UPS Type Nominal output power (PF = 1) ON LINE - Double conversion (1) 25 load AC/AC efficiency (VFI - ON LINE Double conversion) AC/AC load (VI from 50 load) AC/AC efficiency (VFD ECO MODE - from 50 load) AC/AC 100 load (VFD UHE - from 50 load) ,0 94,0 94,0 94,0 94,0 94,0 94,0 94,5 94,5 94,5 94,5 94,5 94,5 94,5 95,0 95,0 95,0 95,0 95,0 95,0 95,0 95,5 95,5 95,5 95,5 95,5 95,5 95,5 50,9 59,4 67,9 > 97,0 > 98,0 > 99,4 Heat dissipation in VFI mode (PF = 0,9) kw 17,0 25,4 33,9 42,4 UPS ambient operating temperature range C BATTERY ambient operating temperature for maximum design life UPS storage temperature range C C BATTERY storage temperature range C Relative humidity (non-condensing) < 95 Altitude m < 1000 (Above sea level) According to EN Power derating for altitude > 1000 m Ventilation Request cooling air volume (VFI) 0,5 power derating every 100 m Forced 3 m /h < 50 (UHE) Audible noise level (according to EN ) Number of battery cells Protection degree (closed / open doors) Electromagnetic compatibility Safety Test and performance Paint db < 63 (Double conversion) IP30 / IP20 According EN (CE marking) According to EN According to EN RAL 9005 (others available on request) Accessibility Front and top access for service Installation No rear and side gap required 10

9 No. of power modules No. of lateral distribution sections Power module dimensions Distribution section dimensions I/O module width UPS width UPS depth UPS height L 600 W H L 350 W H DB + DSB CB + DSB DB + CSB CB + CSB DB + DSB CB + DSB mm DB + CSB CB + CSB mm kg DB + DSB CB + DSB DB + CSB CB + CSB DB + DSB CB + DSB DB + CSB CB + CSB kg kg Transport Storage and transport conditions Design standard Front operator panel 5560 (separate input lines) and output Forklift handling 3 copper bar terminals for battery connection According to EN Bottom cable entry (top entry configuration on request) EN EN EN ISO 9001: ISO 11 Touch screen display Standard contacts for the following Standard interfaces Serial communication interface Parallel configuration (optional) 4 copper bar terminals for rectifier and bypass input Input/output terminal board Power module weight UPS weight (without batteries) mm I/O module and distribution section weight mm EPO - MBCB - OCB - BCB Standard: RS232/USB Optional: RS485 (Modbus protocol) Optional: RS485 (Teleservice) Up to 5+1 units (redundant parallel configuration) (4) Up to 6 units (power parallel configuration)

10 UPS INPUT: Rectifier and Battery Charger POWER kva 600 Input Three-phase + Neutral Nominal input voltage Vac Range Input frequency (adjustable) Hz -20 / /- 10 > 0,99 DC output voltage accuracy <3 +/- 1 DC output voltage ripple <1 (rms) Range Input power factor Input current THDi at nominal voltage and THDV < 100 load Battery charger characteristic Maximum recharging current (per module) - at nominal load IU (DIN 41773) A 30 IGBT (PFC) 100 Fuses converter type -AC-DC with DCM function Input protection Nominal current absorbed from mains (@ nominal load and fully charged Maximum battery) current absorbed from mains A (@ nominal load, maximum recharging current and Walk-in timenominal input voltage) A s 5 30 (programmable) Hold-off time s (programmable) BATTERY POWER kva 600 Number of cells voltage Inverter input power 610 kw Inverter input current 372 cells Vdc 360 cells Battery test cells 372 cells 360 cells 372 cells (@ nominal load cos φ = 1) Battery protection (@ nominal load cos φ = 1) VRLA (Lead acid Maintenance free) Battery type Floating 25 C End of Discharge (EoD) 1000 A Fused switch box available on request Manual or automatic (programmable) 2705

11 UPS Output: Inverter POWER kva 600 Inverter bridge IGBT (PWM) Nominal output apparent power PF = 1 Nominal output real power PF = 1 (1) DC/AC efficiency kva kw /- 2 (other10on request) 25 load 50 load 97,0 (of each power module) Output Nominal Output Voltage 75 load Three-phase + Neutral ,0-415 Vac Output Voltage Stability - Static (balanced 100 load - Static (unbalanced load) - Dynamic (Step load ) - Output voltage recovery time after step load Phase Angle Accuracy - EN classification Balanced load - Unbalanced load ( ) Output Frequency Output Frequency Stability 97,0 +/- 1 +/- 2 +/- 5 ms < 20 Hz VFI-SS-111 +/ /- 2 Hz +/- 0,001 - Synchro w/internal quartz oscillator (mains fault) - Synchrooutput w/ mains Nominal current (@ Vac) > Slew rate A Hz min min Hz/s (1) Overload capability Short circuit current (half cycle) > Short circuit characteristics Selectivity >150 sec A < Electrical short circuit protection (current limited at above 10 values) with automatic switch off after 5 seconds. Within 1/2 cycle Type gl rated at 20 of nominal output current (within ½ Maximum distribution fuse (selectivity) Output waveform cycle) Sinusoidal Output harmonic distortion THDv - Linear load - Non-linear load Maximum crest factor without derating - EN <1 3<: 51 Fully compliant

12 UPS OUTPUT: Bypass Automatic static bypass Electronic Thyristor switch Input 3 Phase + Neutral Protection Fuses Nominal input voltage Vac Range (adjustable) Nominal input frequency Hz +/ Range (adjustable) +/- 10 Transfer mode No break In case of: - Static Switch test Transfer inverter --> automatic bypass (VFI) - Inverter Test Inverter not operating -- Automatic Retransfer automatic bypass --> inverter (VFI) Over load capability Battery of discharge -- Block onend bypass after 6 transfers within permanent 2 minutes, reset by front panel for 1 cycle - Electronically controlled Manual bypass (optional disconnector) (1) Up to 40 C Battery and static bypass arrangement (4) Included H=145 mm base frame For other configurations ask AVK Technical Department DB: Distributed Battery CB: Centralised Battery DSB: Distributed Static Bypass CSB: Centralised Static Bypass AVAILABLECONFIGURATIONS 1. DISTRIBUTED BATTERY 2. CENTRALISED BATTERY 3. DISTRIBUTED STATIC BYPASS 4. CENTRALISED STATIC BYPASS - No break

13 Case study Eni Green Data Center Key players Maximum protection at the highest efficiency thanks to new technologies Borri designs and manufactures a new generation of UPS based on patented technology Green Conversion to meet the requirements of Eni End-user Eni is one of the largest integrated energy companies in the world, operating in the sectors of oil and gas exploration & production, international gas transportation and marketing, power generation, refining and marketing, chemicals and oilfield services. Eni is active in 90 countries with 78,000 employees. Consultants Founded in 1992, Ariatta Ingegneria dei Sistemi specializes in consulting, design, project coordination and management of technical plants in civil, industrial, healthcare and urban fields. Since 2000 the firm has designed electrical plant infrastructures for more than one million euros cooperating with the most eminent international architects and, in most cases, it has also managed the construction work, following the start-up and functional tests. Marco Negri and Walter Nardelli (Reorder) were entrusted with the scientific supervision. Eni Green Data Center Building area: 45,000 m2 Data rooms area: 5,200 m2 in 6 IT rooms (2,600 m2 phase 1) IT systems 7,000 Core CPUs 60,000 PUE <1.2 Reduction of CO 2 emissions 335,000 tons per year Electric Power by UPS 30 MW The challenge Eni has decided to build a new data centre in Italy, located in Ferrera Erbognone, Pavia adjacent to Enipower s power plant to host all their data processing systems, including administrative information and high performance computing calculation systems (HPC). The company Ariatta was entrusted with the direction of the project, design, execution and supervision of works. The goal of the project is to reach an annual average PUE (Power Usage Effectiveness) value of less than 1.2. Our solution AVK has developed a double conversion, transformer-free 200 kw UPS which is based on two innovative technologies: High double conversion efficiency, up to 95 based on Green Conversion patented technology Ultra High Efficiency (UHE) reaching efficiency based on Borri off-line technology Benefits are: Low dissipation losses of the UPS, in addition to saving electrical energy, minimize room cooling by virtue of negligible heat release. Automatic or manual switching from one mode of operation to another always optimizes critical loads power supply efficiency. The system AVK UPS are powered by two independent lines, coming from two separate medium voltage transformers. Should the main line fail, the system automatically switches on the backup line. The uninterruptible power supply section consists of no kw UPS for both lines, A and B, feeding the server rooms via a double busbar. The UPS is cooled by natural air convection and the design ambient temperature is 50 C. Each UPS is equipped with its own battery cabinet, providing 5 minutes autonomy at full load.

14 Validation tests A testing schedule was included in the project. All tests, commissioned by Eni, have been developed by the Electrical, Electronic and Information Engineering Department at the University of Bologna and conducted by TÜV laboratories. The test results show that B UPS exceeded the 99.4 target On-line double conversion efficiency versus load efficiency, achieving a remarkable efficiency at 50 load and efficiency at 100 load. All the remaining CE mark type tests, namely electromagnetic compatibility, safety and performance were carried out at Bor in our testing area UHE efficiency versus load Efficiency Efficiency Borri Competitor 1 Competitor load Results and future developments load The development of 200 kw UPS for Eni has allowed us to respond to the technological challenge of designing a UPS powering the critical loads of a modern data center to get the highest ever value of PUE. The low losses of the UPS and the high temperature design (50 C rather than the standard 40 C) allow the use of air at ambient temperature to cool We completed a challenging and innovative project with ambitious goals that required all the key players to think outside thebox. Borri created a new technology Green Conversion, proving its ability to fulfil this requirement. Excellence has therefore been achieved thanks to those who have expressed willingness to think of something completely new the local UPS, physically demonstrating the advantages of the solution adopted. The UPS section covered by AVK consists of kw UPS, but it is expected that an expansion will bring the UPS installed to 150 units for a total computing power of 30 MW with an energy saving of 1.5 MW. The contribution of Borri was not limited to the supply and installation of high-efficiency UPS but it was fundamental in the preparation ofthe project. I really appreciated their proactive attitude, contribution of innovative ideas, collaboration in the analysis of feasibility and availability during all its phases confirming Borri s vocation to providing solutions based on the specific needs of its customers. Michele Mazzarelli Alberto Ariatta Vice President Project Manager Programme Eni Green Data Center Project Director and Director of works for Eni Green Data Center

15 Job References Project Name IX Europe EDS Deutsche Bank Infinity Slough - UPS MOD Prauge O2 Main Data Centre Lloyds Data Centre Lloyds Data Centre Three Mobile South Yorkshire Police Cheshire Police H3G Data Centre Qty Module Rating (Total) Total Rating kVA 600kVA kva 9,000kVA 5,000kVA 3,600kVA 3,600kVA 3, 3, 3,200kVA 3,000kVA 3,000kVA 3,000kVA 2, 2,000kVA 2,000kVA

16 About us The largest supplier of Data Centre, Financial and Telecoms sector critical power solutions in the UK. continued steady and consistent growth, not only in size, but also our reputation We are trusted by many of the UK's largest Blue Chip companies to design, install and maintain 100 power integrity to guarantee their operations when mains power fails. AVK has a unique capability for design, manufacture, installation and on-going maintenance of standby power systems containing UPS systems and standby diesel generators. We provide expertise in the design, planning and implementation of power s systems projects in all major market sectors ranging from Data Centres, Banking & Finance and Telecommunications through to Industrial & Public from standard configurations to special applications. It is our aim to provide maximum support to our clients coupled with reliable, high quality products delivered on time and within budget, working closely with you to ensure an efficient and effective system design. www. plus.google.com/+avkseg mission critical services & systems. Since our founding in 1989, AVK have had For over 25 years we've been providing reliable back-up power solutions for

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC) TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)

More information

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out) TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

60 to 160 kva.

60 to 160 kva. 60 to 160 kva www.borri.it Low TCO, efficient and compact solution for supplying reliable uninterrupted quality power to all critical applications in networking and small to medium datacenter, health,

More information

Modular UPS for large data centres 400 kw to 1.6 MW with innovative green technology for unmatched energy savings

Modular UPS for large data centres 400 kw to 1.6 MW with innovative green technology for unmatched energy savings Modular UPS for large data centres 400 kw to 1.6 MW with innovative green technology for unmatched energy savings UPSaver by Borri, 400 kw to 12.8 MW modular series for the data centre industry, totally

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01

More information

Technical Data Sheets

Technical Data Sheets Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH

More information

1.1 GENERAL CHARACTERISTICS

1.1 GENERAL CHARACTERISTICS 1.1 GENERAL CHARACTERISTICS General characteristics - Frame Values Unit Model: Conceptpower DPA 500, UL Series Power, rated: Apparent 500 kva Active 500 kw Power, range 100-3000 kw UPS type: online, transformerless,

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA Est.1968 ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA Maximise your availability with ComPower Mini Designed and Published by Thycon. ComPower Mini is a midsize, three-phase UPS system that delivers premium

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Features and benefits. Applications

Features and benefits. Applications www.borri.it Low Total Cost of Ownership, high efficiency and compact solution for supplying reliable uninterrupted quality power to all critical applications in networking and medium to large data center,

More information

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems Liebert Hipulse E The High-ECO-Availability UPS AC Power Systems We re Emerson Network Power, backed by Emerson, a global company that brings technology and engineering together to provide innovative solutions

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

MKN-DSP SERIES - THREE PHASE

MKN-DSP SERIES - THREE PHASE Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers 250-800kVA Liebert NX Enterprise-Scale UPS Protection For Medium And Large Data Centers Efficiency. Availability. Capacity. Control. Facility managers continue to face the increasing cost of energy consumption

More information

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 400/500 kw With eboost Technology TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerWave 33 Efficient power protection for today s IT and process-related work environments ARTICLE OR CHAPTER TITLE PowerWave 33 Efficient power protection for today s IT and process-related work environments Cooling fan UPS control panel Maintenance bypass isolator Input supply isolator Slot

More information

Master Plus kva

Master Plus kva Local Area Networks (LAN) ServerS Data Centers Telecommunication devices e-business (Servers Farms, ISP/ASP/POP) Industrial Processes Industrial PLCs Electromedical Devices Emergency Devices (lights/alarms)

More information

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability Three-phase UPS system DPA UPScale ST 10 120 kw Best-in-class modular UPS for maximum availability Designed to provide large system benefits for medium power applications Designed for medium power applications,

More information

Liebert. FP 50Z kva

Liebert. FP 50Z kva Liebert FP 50Z 5 250 kva Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at a lower cost when search and social

More information

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL Local Area NETWORKS (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Industrial PFC UPS System

Industrial PFC UPS System Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) Local Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology TLE Series UPS 750/1000 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS Transformer-free. High Efficiency, Scalable On-line UPS LIEBERT Liebert NX NX TM TM UPS 250-250kVA 1000-1000kVA Facility managers continue to face the increasing outlay of energy consumption and the call

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Est FlexiPower Mini UPS FPX Mini kVA

Est FlexiPower Mini UPS FPX Mini kVA Est.1968 FlexiPower Mini UPS FPX Mini 10 200kVA The FlexiPower Mini ST is designed to provide medium critical power users the highest flexibility and growth opportunity platform available today utilising

More information

MGE TM Galaxy TM 7000

MGE TM Galaxy TM 7000 MGE TM Galaxy TM 7000 Power efficiency for business continuity 160/200/250/300/400/500 kva > Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Medium to Large

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications Three-phase UPS system DPA UPScale ST 10 200 kw The modular UPS designed for lowand medium-power applications DPA UPScale ST always protecting your critical applications Up to 10 modules in parallel per

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company imagination at work QUITO: Elia Liut N45-26 y Edmundo Chiriboga Telf:

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 100 &120 PurePulse TM SG Series 60 & 80 PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

MGE TM Galaxy TM 7000 GFC

MGE TM Galaxy TM 7000 GFC MGE TM Galaxy TM 7000 GFC Grid Frequency Converter (GFC) for Shore Connection solution 500 kva Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Shore Connection

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Green Power 2.0 MASTERYS GP

Green Power 2.0 MASTERYS GP Green Power 2.0 MASTERYS GP 60 to 120 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

ConceptpowerTM Modular kVA

ConceptpowerTM Modular kVA TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA

More information

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market Modular architecture easily expandable up to 1.5 MW Low cost of ownership Flexible and highly efficient

More information

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase Local Area Networks (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES TRIMOD HE UPS MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES TRIMOD HE HIGH performance HIGH efficiency LOW environmental impact DEVELOPMENTS

More information

PowerScale TECHNICAL SPECIFICATIONS

PowerScale TECHNICAL SPECIFICATIONS PowerScale TECHNICAL SPECIFICATIONS PowerScale highlights at a glance Best in class efficiency Cost savings during the entire life-cycle(tco) Low input harmonic distortion Cost saving during installation

More information

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

PowerScale kva Technical Specifications

PowerScale kva Technical Specifications PowerScale 10-50 kva Technical Specifications Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 POWERSCALE SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS... 4 10.2.1 MECHANICAL CHARACTERISTICS

More information

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms) LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES BM Plus Series BMLM 10-20 kva Single-phase BMLT 10-120 kva Three-phase CASH REGISTERS TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP)

More information

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004 SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004 Applications Computer and Data Centers Server Farms Process Control Broadcasting / SAT Systems Radar control installations Air traffic control

More information

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations Standalone three-phase UPS system PowerWave 33 S3 60 120 kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations Innovative technology delivering unmatched

More information

Master Plus kva

Master Plus kva LOCAL AREA NETWORKS SERVERS DATA CENTERS TELECOM MUNICATION DEVICES (Servers Farms, ISP/ASP/POP INDUSTRIAL PROCESSES INDUSTRIAL PLCS MEDICAL DEVICES EMERGENCY DEVICES ights/alarms Master Plus 100- kva

More information

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS MODEL NUMBER: S3M60KX Highlights Best-in-class footprint and power density minimize space requirements for up to 60kVA

More information

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva Power Safety Protect 8. Industrial UPS Protect 8.31 Single Phase output 10 kva 120 kva Protect 8.33 Three Phase output 10 kva 120 kva 400 V AC input 220 V DC The Building Block UPS Engineering is our Business

More information

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution 10kVA - 60kVA Compact, Efficient, and Reliable Power Solution Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at

More information

Master DIALOG INDUSTRY RANGE

Master DIALOG INDUSTRY RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications

More information

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99 80-125 kva/kw E Three-Phase Double-Conversion On-Line Full Four Year Warranty www.stacoenergy.com Up to 99% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front,

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Three Phase UPS Systems

Three Phase UPS Systems Three Phase UPS Systems Range: 10 to 500kVA MEDICAL PLASTIC AUTOMOBILE PULP & PAPER PACKAGING Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems

More information

Marketing Management Team of Europe

Marketing Management Team of Europe Emerson Network Power Liebert NXe UPS GUIDE SPECIFICATIONS For a 10 to 20 kva (50 or 60Hz) Parallelable Digital Uninterruptible Power Supply (UPS) System - 1 - Contents 1.1 SUMMARY... 3 1.2 STANDARDS...

More information

MASTERYS IP+ 10 to 80 kva

MASTERYS IP+ 10 to 80 kva MASTERYS IP+ 10 to 80 kva OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application. the information

More information

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems. SENTRY HPS HM/HT provides maximum protection for vital mission-critical networks, security applications (electro-medical) and industrial applications thanks to its outstanding mechanical and electrical

More information

Est DCM Double Conversion Module 400kVA - 800kVA

Est DCM Double Conversion Module 400kVA - 800kVA Est.1968 DCM Double Conversion Module 400kVA - 800kVA The parallel operation of converters for increased output power or redundancy is commonplace but poses problems for large systems. A new approach is

More information

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет --------- l -' un I Jet, ИБП ABB Conceptpower DPA 500 (100-500 квт) - технические спецификации. Юниджет Постоянная ссылка на страницу: https://www.uni-jet.com/catalog/istochnikibesperebojnogo-pitaniya/on-line-ibp-100-kva/abb-conceptpower-dpa-series.html

More information

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY VFI TYPE ONLINE Master MPS 3:1 3:3 10-100 kva 10- kva 4 SmartGrid ready f lywheel compatible Supercaps UPS Service 1st start HIGHLIGHTS Efficiency Control

More information

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY VFI TYPE ONLINE Master MPS 3:1 3:3 10-100 kva 10- kva 4 SmartGrid ready Flywheel compatible Supercaps UPS Service 1st start Highlights Efficiency Control

More information

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications True double-conversion online single-phase UPS PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications Safeguarding your power supply has never been easier One factor has become increasingly

More information

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES Keor MOD THREE-PHASE MODULAR UPS up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES 2 CONTENTS 4 MORE THAN A UPS 6 TECHNOLOGY AND DESIGN 8 IDEAL FOR IT INFRASTRUCTURES 10 A COLLABORATION

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models and uses

More information

MGE Galaxy 5500 Marine

MGE Galaxy 5500 Marine MGE Galaxy 5500 Marine 20/30/40/60/80/100/120 kva UPS solutions for marine and offshore environments 20-to-120 kva, state-of-the-art, three-phase power protection designed to meet a wide range of requirements

More information

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery

More information

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection Galaxy VM From 160 kva to 1000 kva, 160 kva or 200 kva modular approach Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase

More information

HAIRF UPS. X5 Series KVA

HAIRF UPS.   X5 Series KVA HAIRF UPS www.hairf.com.cn X5 Series 10-200KVA Company Profile Hairf is an international leading supplier of critical power supply units and refrigerating systems for equipment rooms. Main products of

More information