PV Solar Proposal. Harmon Electric. Presented by: Robert Wittmann, Energy Consultant (480)
|
|
- Arron Jared Kennedy
- 5 years ago
- Views:
Transcription
1 PV Solar Proposal Harmon Electric Presented by: Robert Wittmann, Energy Consultant (480) Turnkey PV solar solution presented for Harmon Electric
2 Table of Contents I. Introduction 2 II. Solar Layout 3 III. PV System Description 4 IV. Turnkey Price 5 V. System Performance Summary & Cash Flow Detail PURCHASE 6 VI. System Performance Summary & Cash Flow Detail LOAN 8 VII. Levelized Energy Cost 10 VIII. Reduction of Carbon Footprint 11 IX. Implementation Schedule 12 X. Exhibits 13 a. Solar Layout b. Q-Cells Module Spec Sheet c. SMA Inverter Spec Sheet 1
3 January 19, 2016 Mr. Harmon Harmon Electric 945 W. Deer Valley Rd. Phoenix, AZ Mr. Harmon Harmon Solar is pleased to present you our solar proposal for your Harmon Electric building in Phoenix, Arizona. Harmon Solar a division of Harmon Electric, Inc. provides solar and electrical services for commercial, industrial, and residential customers throughout the state of Arizona. Proudly serving Arizona since 1975, our highly skilled team of electricians, technicians, designers, and project managers bring decades of experience to each project. Quality craftsmanship, integrity, and a commitment to customer satisfaction have been the driving force in serving a variety of industries including, renewable energy and utilities. Our qualified team will bring the utmost value to you through experienced and innovative design combined with the expert execution of our project management and construction team. Harmon has installed over 24 MW of solar throughout Arizona. We are confident we offer the highest quality competitive solutions for the deployment of renewable assets. We are excited for this potential opportunity and look forward to working with you on this and future projects. Sincerely, Robert Wittmann Robert Wittmann Energy Consultant 2
4 Harmon Electric Solar Layout 3
5 System Description Harmon Electric Design Considerations Module/Racking Layout Harmon Solar is proposing a system on the roof to interconnect with the meter feeding your suite in the building. The kwp array is consisting of 448 Q-Cells 260 watt modules on the existing roof. The roof system brings the best economics to the project. System Sizing The system is designed to offset the energy consumption (kwh) on the interconnecting meter. Inverter and Gear Location Inverters and gear will be located near the electric meter and SES. Module Selection The proposed design is using Q-Cells 260 watt, modules (spec sheet included in the exhibits). Q-Cells modules are characterized by high yields and excellent reliability. Q-Cells includes a 12 year product warranty and a 25 year linear performance guarantee. Inverter Selection Our proposed design is for SMA Inverters. SMA boasts the highest reliability and efficiency in the industry. SMA inverters carry a standard 10-year warranty with options to extend up to 20 years. 4
6 Turnkey Price Renewable Energy Power System Proposal Project: Harmon Electric Project Address: 945 W. Deer Valley Dr., Phoenix, AZ TOTAL PROJECT INSTALLATION COST: $266,556 (about $2.29/Wp) PROJECT DESCRIPTION & COMPONENTS: Array: Turnkey solar array installed on the existing roof System Size Total: kwp Major System Components Included in Price PV Panels: Qty. (448) 260 Watt Q-Cells (12 year product warranty, 25 year linear performance guarantee) Inverter: Qty. (4) SMA Tripower 24000TL-US (10 year standard warranty) Additional Included Components & Allowances - Furnish and install racking on roof - Furnish and install modules on roof - Necessary conduits, wires, combiners and disconnects - Necessary components to interface array with SES - Basic Inverter Monitoring - Structural Engineering - Electrical Engineering - Permit Fees - Utility paperwork and agreements - Labor - 2 year installation warranty Excluded Items - Any structural improvements - Relisting, repair, upgrade or replacement of existing SES This PV Solar Proposal is valid 30 days. 5
7 System Performance Summary & Cash Flow PURCHASE Electric Utility Savings: Anticipate a savings of approximately $21,648 in electric bills at current utility rates in the first year. Savings will grow as electric utility rates are expected to rise 3.00% a year. Over 25 years, annual utility savings are anticipated to average $32,387, for a total utility savings of $809,682. After tax effects are applied, savings average $21,699 annually or $542,486 over the system life. Performance Summary Solar Electric (PV) System: kw DC producing 196,847 kwh/year. Purchase Price & Net Cost Contract Price: $266,556 Incentives to Customer: ($104,967) Net Purchase Cost: $161,589 MACRS Bonus Depreciation: ($60,765)(P.V.) Net-Present Cost: $100,824 Includes present value (P.V.) of these future cash flows. Financial Ratios Cashflow Payback: 5.9 years 6.1 years (modified) Internal Rate of Return (IRR): 15.3% Net Present Value (NPV): $170,435 Cash Gained over Life: $424,203 Harmon Solar does not provide tax or legal advice. Please consult with a tax advisor or accountant. Calculations are for information purposes. Estimates and savings cannot be guaranteed. 6
8 Cash Flow Detail PURCHASE Cash Flows in Year Gross Cost: PV (266,556) Reference: Utility Bill Savings with Inflation Applied 0 22,297 22,960 23,641 24,344 Utility Bill Net Cash Savings after Tax Effects 0 14,939 15,383 15,839 16,310 Solar Electric (PV) Incentives AZ Corporate Tax Credit (10% of Gross Cost) 25, Federal Tax Credit (30% of Gross Cost at Installation) 79, Total Incentives 104, Federal MACRS Bonus Depreciation Tax Savings 0 33,864 9,030 5,418 3,251 State MACRS Bonus Depreciation Tax Savings 0 6,047 1, Net Annual Cash Flow (161,589) 54,850 26,026 22,225 20,142 Cumulative Cash Flow (161,589) (106,739) (80,713) (58,488) (38,346) Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 25,066 25,810 26,577 27,366 28,179 Utility Bill Net Cash Savings after Tax Effects 16,794 17,293 17,807 18,335 18,880 Federal MACRS Bonus Depreciation Tax Savings 3,251 1, State MACRS Bonus Depreciation Tax Savings Net Annual Cash Flow 20,626 19,208 17,807 18,335 18,880 Cumulative Cash Flow (17,720) 1,488 19,295 37,630 56,510 Cash Flows in Year O&M Cost: PV 0 0 (34,646) 0 0 Reference: Utility Bill Savings with Inflation Applied 29,016 29,877 30,764 31,678 32,618 Utility Bill Net Cash Savings after Tax Effects 19,441 20,018 20,612 21,224 21,854 Tax Savings from O&M Expense Deduction , Net Annual Cash Flow 19,441 20,018 (2,601) 21,224 21,854 Cumulative Cash Flow 75,951 95,969 93, , ,446 Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 33,586 34,584 35,611 36,668 37,757 Utility Bill Net Cash Savings after Tax Effects 22,503 23,171 23,859 24,568 25,297 Net Annual Cash Flow 22,503 23,171 23,859 24,568 25,297 Cumulative Cash Flow 158, , , , ,844 Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 38,877 40,033 41,221 42,445 43,705 Utility Bill Net Cash Savings after Tax Effects 26,048 26,822 27,618 28,438 29,282 Net Annual Cash Flow 26,048 26,822 27,618 28,438 29,282 Cumulative Cash Flow 281, , , , ,052 Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 45, Utility Bill Net Cash Savings after Tax Effects 30, Net Annual Cash Flow 30, Cumulative Cash Flow 424,
9 System Performance Summary & Cash Flow LOAN Electric Utility Savings: Anticipate a savings of approximately $21,648 in electric bills at current utility rates in the first year. Savings will grow as electric utility rates are expected to rise 3.00% a year. Over 25 years, annual utility savings are anticipated to average $32,387, for a total utility savings of $809,682. After tax effects are applied, savings average $21,699 annually or $542,486 over the system life. Performance Summary Solar Electric (PV) System: kw DC producing 196,847 kwh/year. Purchase Price & Net Cost Contract Price: $266,556 Incentives to Customer: ($104,967) Net Purchase Cost: $161,589 MACRS Bonus Depreciation: ($60,765)(P.V.) Net-Present Cost: $100,824 Includes present value (P.V.) of these future cash flows. Financial Ratios (Unlevered) Internal Rate of Return (IRR): 12.3% Net Present Value (NPV): $134,106 Cash Gained over Life: $380,282 Finance: Loan: "Fully-Amortized". about 90% of Contract Price $240,000 Principal at 5.0% APR. Repaid: $2,546 per month over 120 months. Loan processing fees $500. Initial Cash Proceeds: $78,411 Harmon Solar does not provide tax or legal advice. Please consult with a tax advisor or accountant. Calculations are for information purposes. Estimates and savings cannot be guaranteed. 8
10 Cash Flow Detail LOAN Cash Flows in Year Gross Cost: PV (266,556) Reference: Utility Bill Savings with Inflation Applied 0 22,297 22,960 23,641 24,344 Utility Bill Net Cash Savings after Tax Effects 0 14,939 15,383 15,839 16,310 Solar Electric (PV) Incentives AZ Corporate Tax Credit (10% of Gross Cost) 25, Federal Tax Credit (30% of Gross Cost at Installation) 79, Total Incentives 104, Federal MACRS Bonus Depreciation Tax Savings 0 33,864 9,030 5,418 3,251 State MACRS Bonus Depreciation Tax Savings 0 6,047 1, Loan Principal & Payments 240,000 (30,552) (30,552) (30,552) (30,552) Tax Savings on Loan Interest Paid 0 3,818 3,497 3,160 2,806 Net Annual Cash Flow 78,411 28,116 (1,029) (5,167) (7,604) Cumulative Cash Flow 78, , , ,331 92,727 Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 25,066 25,810 26,577 27,366 28,179 Utility Bill Net Cash Savings after Tax Effects 16,794 17,293 17,807 18,335 18,880 Federal MACRS Bonus Depreciation Tax Savings 3,251 1, State MACRS Bonus Depreciation Tax Savings Loan Principal & Payments (30,552) (30,552) (30,552) (30,552) (30,552) Tax Savings on Loan Interest Paid 2,434 2,043 1,631 1, Net Annual Cash Flow (7,492) (9,301) (11,114) (11,018) (10,928) Cumulative Cash Flow 85,235 75,934 64,820 53,802 42,874 Cash Flows in Year O&M Cost: PV 0 0 (34,646) 0 0 Reference: Utility Bill Savings with Inflation Applied 29,016 29,877 30,764 31,678 32,618 Utility Bill Net Cash Savings after Tax Effects 19,441 20,018 20,612 21,224 21,854 Tax Savings from O&M Expense Deduction , Loan Principal & Payments (30,552) Tax Savings on Loan Interest Paid Net Annual Cash Flow (10,844) 20,018 (2,601) 21,224 21,854 Cumulative Cash Flow 32,030 52,048 49,447 70,671 92,525 Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 33,586 34,584 35,611 36,668 37,757 Utility Bill Net Cash Savings after Tax Effects 22,503 23,171 23,859 24,568 25,297 Net Annual Cash Flow 22,503 23,171 23,859 24,568 25,297 Cumulative Cash Flow 115, , , , ,923 Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 38,877 40,033 41,221 42,445 43,705 Utility Bill Net Cash Savings after Tax Effects 26,048 26,822 27,618 28,438 29,282 Net Annual Cash Flow 26,048 26,822 27,618 28,438 29,282 Cumulative Cash Flow 237, , , , ,131 Cash Flows in Year Reference: Utility Bill Savings with Inflation Applied 45, Utility Bill Net Cash Savings after Tax Effects 30, Net Annual Cash Flow 30, Cumulative Cash Flow 380,
11 Levelized Energy Cost (LEC) Your Hedge Against Utility Inflation: Your investment in this project will protect you from utility rate inflation. Levelized Energy Cost (LEC) analysis provides us with a "hurdle rate" (the levelized energy cost) which can be compared to the expected change in utility rates (by way of utility rate inflation). LEC is the average lifetime cost of energy produced by a particular system. We can compare the LEC to the current utility rate and its expected change in price as time goes on. In this manner one can judge the investment as a "better bet" than utility rates to contain energy costs. Represented below is the average cost of utility energy versus the cost of energy produced (LEC) by your system over time. Electric: Levelized Energy Cost (LEC) 10
12 Carbon Footprint Reduction Over the life of your system 4,035 tons of carbon dioxide (CO2) will be eliminated from your footprint. 4,035 Tons of CO2 is Equivalent to: Planting 94,016 trees. Driving reduced by 8,070,000 auto miles, or 411,570 gallons of gasoline. Displacing CO2 emissions from the annual electric use of 457 homes. 3,931,790 pounds (1,966 tons) of coal burned. 11
13 Implementation Schedule today Argeement signed with 20% deposit 4 weeks Engineering the solar installagon 4 weeks Permihng in City of Phoenix 6 weeks Construcgon 2 weeks APS Commissioning Total Project 4 months Harmon Solar Sample Installations 12
14 CODE INDET NO. Exhibits N SOLAR PHOTOVOLTAIC Q-Cells 260 PANELS FLAT ROOF SYSTEM 448 PANELS x 260 Wp 4 SMA Tripower TL kwp DRAFT PANEL LAYOUT SCALE: N.T.S. 945 W Deer Valley Road Phoenix, AZ APPROVALS DATE DRAWN: R. WITTMANN CHECKED: ENGINEER: R. WITTMANN MANAGER: REVIEWED: PROJECT #: AZ SIZE: 24 x 36 PANEL LAYOUT 96 kw PHOTOVOLTAIK SYSTEM Harmon Electric 945 W Deer Valley Rd, Phoenix, AZ SCALE: REV: DRAWING NO.:
15 Q.PRO BFR-G POLYCRYSTALLINE SOLAR MODULE The new Q.PRO BFR-G4 is the result of the continued evolution of our Q.PRO family. Thanks to improved power yield, excellent reliability, and high-level operational safety, the new Q.PRO BFR-G4 generates electricity at a low cost (LCOE) and is suitable for a wide range of applications. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 16.2 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti-PID Technology1, Hot-Spot-Protect and Traceable Quality Tra.Q. LIGHT-WEIGHT QUALITY FRAME High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). YIELD SECURITY ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) MAXIMUM COST REDUCTIONS Up to 10 % lower logistics costs due to higher module capacity per box. TRACEABLE QUALITY (TRA.Q ) SAFE ELECTRONICS Protection against short circuits and thermally induced power losses due to breathable junction box and welded cables. A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. MOD:27898 high reliability low degradation frequent 1 THE IDEAL SOLUTION FOR: 2 Rooftop arrays on residential buildings Rooftop arrays on commercial / industrial buildings Ground-mounted solar power plants photon.info/laboratory Quality Tested Best polycrystalline solar module 2013 product surveillance Q.PRO-G2 235 ID modules tested APT test conditions: Cells at V against grounded, with conductive metal foil covered module surface, 25 C, 168 h See data sheet on rear for further information.
16 SUNNY TRIPOWER 12000Tl-US / 15000Tl-US / 20000Tl-US / 24000TL-US STP 12000Tl-US-10 / STP 15000Tl-US-10 / STP 20000Tl-US-10 / STP 24000TL-US-10 Design flexibility System efficiency Enhanced safety Future-proof 1000 V DC or 600 V DC Two independent DC inputs 15 to 90 mounting angle range Detachable DC Connection Unit 98% CEC, 98.5% Peak 1000 V DC increases system efficiency OptiTrac advanced MPPT OptiTrac Global Peak MPPT Integrated DC AFCI Floating system with all-pole sensitive ground fault protection Reverse polarity indicator Complete grid management feature set Cluster Controller, WebConnect/ Speedwire Bi-directional Ethernet communications Ability to satisfy future utility requirements Sunny Tripower 12000TL-US / 15000TL-US / 20000TL-US / 24000TL-US The ultimate solution for decentralized PV plants The world s best-selling three-phase PV inverter, the SMA Sunny Tripower TL-US, is raising the bar for decentralized commercial PV systems. This three-phase, transformerless inverter is UL listed for up to 1000 V DC maximum system voltage and has a peak efficiency above 98 percent, while OptiTrac Global Peak minimizes the effects of shade for maximum energy production. The Sunny Tripower delivers a future-proof solution with full grid management functionality, cutting edge communications and advanced monitoring. The Sunny Tripower is also equipped with all-pole ground fault protection and integrated AFCI for a safe, reliable solution. It offers unmatched flexibility with a wide input voltage range and two independent MPP trackers. Suitable for both 600 V DC and 1,000 V DC applications, the Sunny Tripower allows for flexible design and a lower levelized cost of energy.
17 Accessories RS485 interface DM-485CB-US-10 SMA Cluster Controller CLCON-10 Connection Unit CU 1000-US-10 Technical data Toll Free SMA USA Standard features Optional features Not available Data at nominal conditions Sunny Tripower 12000TL-US Sunny Tripower 15000TL-US Sunny Tripower 20000TL-US Sunny Tripower 24000TL-US Input (DC) Max. usable DC power (@ cos ϕ = 1) W W W W Max. DC voltage* 1000 V 1000 V 1000 V 1000 V Rated MPPT voltage range 300 V 800 V 300 V 800 V 380 V 800 V 450 V 800 V MPPT operating voltage range 150 V 1000 V 150 V 1000 V 150 V 1000 V 150 V 1000 V Min. DC voltage / start voltage 150 V / 188 V 150 V / 188 V 150 V / 188 V 150 V / 188 V Number of MPP tracker inputs Max. input current / per MPP tracker input 66 A / 33 A 66 A / 33 A 66 A / 33 A 66 A / 33 A Output (AC) AC nominal power W W W W Max. AC apparent power VA VA VA VA Output phases / line connections 3 / 3-N-PE Nominal AC voltage 480 / 277 V WYE AC voltage range 244 V 305 V Rated AC grid frequency 60 Hz AC grid frequency / range 50 Hz, 60 Hz / -6 Hz +5 Hz Max. output current 14.4 A 18 A 24 A 29 A Power factor at rated power / adjustable displacement 1 / 0.8 leading 0.8 lagging Harmonics < 3 % Efficiency Max. efficiency 98.2 % 98.2 % 98.5 % 98.5 % CEC efficiency 97.5% 97.5% 97.5% 98.0% Protection devices DC reverse polarity protection Ground fault monitoring / Grid monitoring All-pole sensitive residual current monitoring unit DC AFCI compliant to UL 1699B AC short circuit protection Protection class / overvoltage category I / IV I / IV I / IV I / IV General data Dimensions (W / H / D) in mm (in) 665 / 690 / 265 (26.1 / 27.1 / 10.4) Packing dimensions (W / H / D) in mm (in) 780 / 790 / 380 (30.7 / 31.1 / 15.0) Weight 55 kg (121 lbs) Packing weight 61 kg (134.5 lbs) Operating temperature range -25 C C Noise emission (typical) 51 db(a) Internal consumption at night 1 W Topology Transformerless Cooling concept OptiCool Electronics protection rating NEMA 3R Features Display / LED indicators (Status / Fault / Communication) / / / / Interfaces: Speedwire / RS485 / / / / Mounting angle range Warranty: 10 / 15 / 20 years / / / / / / / / Certifications and approvals UL 1741, UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C NOTE: US inverters ship with gray lids *Suitable for 600 V DC max. systems Type designation STP 12000TL-US-10 STP 15000TL-US-10 STP 20000TL-US-10 STP 24000TL-US-10 SMA America, LLC STPTL-US12-24-DUS SMA and Sunny Tripower are registered trademarks of SMA Solar Technology AG. Printed on FSC-certified paper. All products and services described as well as technical data are subject to change, even for reasons of country-specific deviations, at any time without notice. SMA assumes no liability for errors or omissions. For current information, see
18 MECHANICAL SPECIFICATION Format Weight Front Cover Back Cover Frame Cell Junction box Cable Connector 65.7 in 39.4 in x 1.26 in (including frame) (1670 mm 1000 mm 32 mm) lb (18.8 kg) 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Composite film Black anodized aluminum 6 10 polycrystalline solar cells 4.33 in 4.53 in 0.9 in (110 mm 115 mm 23 mm), Protection class IP67, with bypass diodes 4 mm² Solar cable; (+) in (1000 mm), (-) in (1000 mm) Tyco Solarlok PV4, IP " ( " (1670 mm) mm) 38.58" (980 mm) 6 Grounding points ø 0.177" (4.5 mm) Frame Product label 39.37" (1000 mm) Cable with connectors Junction bo 8 Drainage holes 4 Fastening points (DETAIL A) DETAIL A 0.630" (16 mm) 1.26" (32 mm) 0.335" (8.5 mm) 0.965" (24.5 mm) 37.44" (951 mm) 39.4" (1000 mm) ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC 1 (POWER TOLERANCE +5 W /- 0 W) Power at MPP 2 P MPP [W] Short Circuit Current* I SC [A] Minimum Open Circuit Voltage* V OC [V] Current at MPP* I MPP [A] Voltage at MPP* V MPP [V] Efficiency 2 η [%] MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC 3 Power at MPP 2 P MPP [W] Minimum Short Circuit Current* I SC [A] Open Circuit Voltage* V OC [V] Current at MPP* I MPP [A] Voltage at MPP* V MPP [V] W/m², 25 C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 % W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE RELATIVE EFFICIENCY COMPARED TO NOMINAL POWER [%] Q CELLS * Standard terms of guarantee for the 10 PV companies YEARS with the highest production capacity in 2014 (as at: September 2014) TEMPERATURE COEFFICIENTS Industry standard for linear warranties * Industry standard for tiered warranties * PROPERTIES FOR SYSTEM DESIGN RELATIVE EFFICIENCY [%] IRRADIANCE [W/m²] Temperature Coefficient of I SC α [% / K] Temperature Coefficient of V OC β [% / K] 0.30 Temperature Coefficient of P MPP γ [% / K] 0.41 Normal Operating Cell Temperature NOCT [ F] 113 ± 5.4 (45 ± 3 C) Maximum System Voltage V SYS [V] 1000 (IEC) / 1000 (UL) Safety Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating C / TYPE 1 Max Load (UL) 2 [lbs/ft 2 ] 75 (3600 Pa) Permitted module temperature on continuous duty Load Rating (UL) 2 [lbs/ft 2 ] 55.6 (2666 Pa) 2 see installation manual QUALIFICATIONS AND CERTIFICATES UL 1703; VDE Quality Tested; CE-compliant; IEC (Ed.2); IEC (Ed.1) application class A Certified UL 1703 (254141) At least 97 % of nominal power during first year. Thereafter max. 0.6 % degradation per year. At least 92 % of nominal power after 10 years. At least 83 % of nominal power after 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. The typical change in module efficiency at an irradiance of 200 W/m² in relation to 1000 W/m² (both at 25 C and AM 1.5 G spectrum) is -2 % (relative). PACKAGING INFORMATION 40 F up to +185 F ( 40 C up to +85 C) Number of Modules per Pallet 32 Number of Pallets per 53' Container 32 Number of Pallets per 40' Container 26 Pallet Dimensions ( L W H ) Pallet Weight 68.7 in 45.0 in 46.0 in ( mm) 1435 lb (651 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Q CELLS USA Corp. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA TEL WEB Specifications subject to technical changes Hanwha Q CELLS GmbH Q.PRO BFR-G4_ _Rev04_NA
Sunny Tripower CORE1.
Sunny Tripower CORE1 www.smacore1.com It stands on its own Sunny Tripower Core1 stands for commercial solar A global solution optimized for all commercial applications SCALABILITY WITH MAXIMUM ENERGY HARVEST
More informationSMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems
SUNNY TRIPOWER CORE1 SMA COMMERCIAL PRODUCTS Stands on its own. Up to 60 % faster installation for commercial PV systems SUNNY TRIPOWER CORE1 The future for commercial PV systems Scalability for maximum
More informationSUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN
SUNNY TRIPOWER CORE1 UP TO 60% faster installation for commercial PV systems DE STANDS ON ITS OWN Subline lorem ipsum dolor sit amet EN THE FUTURE FOR COMMERCIAL PV SYSTEMS Top performance and maximum
More informationSolar Electric System Proposal
Solar Electric System Proposal Local Solar Professionals Since 2003 Presented To: Michael Donihue 324 Trafton Rd Waterville, ME 04901 Presented By: Hans Albee hans@revisionenergy.com 207-589-4171 April
More informationSolar Energy in BC Presenter Mr. Michel de Spot, P.Eng. About EcoSmart
SOLAR ENERGY IN BC Solar Energy in BC This session will cover all key aspects of solar photovoltaic (PV) projects. In short, a PV system transforms solar irradiance into electricity that can be either
More informationSOLAR4SAVINGS SYSTEMS
PRODUCT CATALOGUE SOLAR4SAVINGS SYSTEMS 3kWp SMA SUNNY BOY GRID TIE AESTHETIC PERFORMANCE HENRY VERMEULEN Sales & Marketing Director Tel: 010 594 7522 Cell: 072 149 9225 Email: henry@value4life.co.za Web:
More informationSUNNY TRIPOWER CORE1 - STP 50-40
Skype bornay@bornay.com (+34) 965 560 025 SUNNY TRIPOWER CORE1 - STP 50-40 Sunny Tripower Core 1, the World's first free standing inverter, with up to 60% faster installation for commercial PV systems.
More informationSAMPLE PERMIT APPLICATION PACKAGE
2013 Lennox Industries Inc. Dallas, Texas, USA SOLAR - KIT / ACCESSORIES 507154-01 3/2013 Supersedes 506555-01 LITHO U.S.A. SAMPLE PERMIT APPLICATION PACKAGE SUNSOURCE HOME ENERGY SYSTEM SAMPLE PERMIT
More informationTotal number of PV modules: 42 Energy usability factor: 99.9 % Number of PV inverters: 1
FILKAB Solar OOD Komatevsko shose 92 4004 Plovdiv, Bulgaria FILKAB Solar OOD Komatevsko shose 92 4004 Plovdiv, Bulgaria Tel.: +359 32 277 298 E-mail: office@filkab.solar Internet: www.filkab.solar Project
More informationSunny Tripower. Can do everything that we can
Sunny Tripower Can do everything that we can New Features Optiflex Flexible Plant Design Optiprotect Electronic String Fuse Optiprotect Integrable Type II Overvoltage Protection Optiprotect Intelligent
More informationGrasshopper Vision. Accelerate the adoption of sustainable practices by creating accessible and affordable products for everyone.
Meeting Objective 1. Who are we? 2. Review Commercial Solar Industry 3. Who are the ideal candidates for solar? 4. Key Site Conditions 5. Typical Upfront and On-going Costs Grasshopper Vision Accelerate
More informationSolarMax MT A series A reliable solution for commercial PV applications
SolarMax MT A series A reliable solution for commercial PV applications yields for commercial plants For more than 20 years, SolarMax has been a pioneer in the development of transformerless inverters
More informationALZ Electrical Solar Consumer Guide
ALZ Electrical Solar Consumer Guide ALZ Electrical Unit 6/3 Southern Cross Circuit, Urangan QLD 4655 T: (07) 4124 9552 E: admin@alzelectrical.net W: www.alzelectrical.net Why go solar? Solar power systems
More informationSOLAR ENERGY KIT MODEL: SISMA-CT20000
SOLAR ENERGY KIT MODEL: SISMA-CT20000 Introduction: SITECNO solar energy kit is on-grid PV system, a complete solution which generates electrical energy for self-consumption and feed surplus energy in
More informationSOLAR ENERGY KIT MODEL: SISMA-CS3500
SOLAR ENERGY KIT MODEL: SISMA-CS3500 Introduction: SITECNO solar energy kit is on-grid PV system, a complete solution which generates electrical energy for self-consumption and feed surplus energy in to
More informationSOLAR4SAVINGS SYSTEMS
PRODUCT CATALOGUE SOLAR4SAVINGS SYSTEMS 3kWp SMA SUNNY BOY GRID TIE HIGH PERFORMANCE HENRY VERMEULEN Sales & Marketing Director Tel: 010 594 7522 Cell: 072 149 9225 Email: henry@value4life.co.za Web: www.value4life.co.za
More informationEnergy Produced by PV Array (AC):
4x17 2x16 400 x PHOTON SOLAR 4 x KACO new energy PH-250P-60 (HDS) INT 250 W Powador 30,0 TL3 15 ; 0 25,0kW Location: Climate Data Record: PV Output: Gross/Active PV Surface Area: Antalya Antalya (1961-1990)
More informationContents. Solar Select TM Frequently Asked Questions
Solar Select TM Frequently Asked Questions Contents Program Overview and How Solar Select Works... 1 Participation Requirements... 3 Cost and Payment... 4 Solar Production... 5 Development, Equipment,
More information500 / 630 / 720 / 760 / 800 / 850 / 900
SUNNY CENTRAL STORAGE 500 / 630 / 720 / 760 / 800 / 850 / 900 SCS 500 / SCS 630 / SCS 720 / SCS 760 / SCS 800 / SCS 850 / SCS 900 Durable Full nominal power in continuous operation at ambient temperatures
More informationFor the highest caliber solar system choose Rosendin Electric s exceptional collaborative team
For the highest caliber solar system choose Rosendin Electric s exceptional collaborative team Our unique team brings you the strongest design recommendations, installation expertise and financial advice
More information18.6% 0-5w. Years. Grid. Certification. BYD PV Module 25 Years Linear Performance Warranty
P6C-30-SERIES-4BB 18.6% Average cell efficiency up to 18.6% Excellent optical performance 0-5w Positive tolerance 0~5W Reliability for output performance 12 Years 12 years for product 25 years linear Warranty
More informationSOLAR4SAVINGS SYSTEMS
PRODUCT CATALOGUE SOLAR4SAVINGS SYSTEMS 4kWp SUNPLUG ECO GRID TIE AESTHETIC PERFORMANCE HENRY VERMEULEN Sales & Marketing Director Tel: 010 594 7522 Cell: 072 149 9225 Email: henry@value4life.co.za Web:
More informationAirports Going SOLAR! Michael Shonka
Airports Going SOLAR! Michael Shonka www.solaromaha.com 402-590-5900 Agenda Why Go SOLAR Solar System Components System Design Long-term Impacts SGHAT - Forge Solar Why Airports Go SOLAR? FREE and abundant
More information24. SOLAR INCENTIVE PROGRAM II
24. SOLAR INCENTIVE PROGRAM II A. General California Senate Bill 1 requires publicly owned utilities that sell electricity at the retail level, to adopt, implement, and fund a solar incentive program for
More informationStation Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)
Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX. 78721 (20) Sharp 208 W Modules = 4.16 kw 0.77/0.94*0.945=0.774 Derate Factor Station Identification City: Austin
More informationEnergy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.
Energy & Cost Savings The Friends Meeting of Austin 371 Martin Luther King Blvd. Austin, TX. 78721 (46) Sharp 28 W Modules = 9.568 kw Station Identification City: Austin State: TX Latitude: 3.3 N Longitude:
More informationEnergy Savings through Solar Energy for Municipalities
Energy Savings through Solar Energy for Municipalities May 2015 2014 Sunvestment Group www.sunvestmentgroup.com Solar Market Growth U.S. US Capacity and Generation: Solar Source: National Renewable Energy
More informationDo It Yourself Solar Photovoltaic (PV) Workshop. Jack Barnett Blair Buselli
Do It Yourself Solar Photovoltaic (PV) Workshop Jack Barnett Blair Buselli 1 Agenda Tonight: Economics and Cost Intro to Photovoltaic (PV) Solar Systems Paperwork & Permitting Roofs and How to Mount Sizing
More informationNet Meter and Production Meter installed by Xcel Energy
INTRODUCTION Net Meter and Production Meter installed by Xcel Energy A solar electric system installed on a home or business and connected to the electrical utility company s service at the same time is
More informationSolar Inverters. No. 6, R. A. De Mel Mawatha, Colombo
Solar Inverters We offer you the right device for each application: for all module types, for grid-connection and feeding into stand-alone grids, for small house systems and commercial systems in the Megawatt
More informationPuget Sound Energy Overview
Northwest Electric Meter School Leslie Moynihan Program Manager, Customer Connected Solar August 2018 Puget Sound Energy Overview Service Area - 6,000+ square miles in 10 Counties Electric - Customers
More informationDatasheets. Residential On-Grid Photovoltaic System Kits
Datasheets Residential On-Grid Photovoltaic System Kits Symtech Solar Product Line 1 RESIDENTIAL 0.5kW / 1.5kW / 2kW / 3kW / 4kW / 5kW / 10kW Product Description Symtech Solar s Residential Solar PV Kits
More information40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3
40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3 Opción Vertido cero: CDP Inyección cero + accesorios * Imágenes de producto no vinculantes. Mono
More informationMANHARI SOLAR. (Your own renewable energy management experts)
MANHARI SOLAR (Your own renewable energy management experts) 100% Accelerated Depreciation Assured Returns (15-40% IRR) Quick Payback Period No Recurring Cost Absolutely No Pollution Reduced Carbon Footprint
More informationAlameda Unified School District
Alameda Unified School District Alameda Unified School District Solar Master Plan Prepared by KyotoUSA May 2014 The purpose of this analysis is to assess the current feasibility of solar projects in the
More informationSample Solar PV Electrical One Line
Design includes a total of 18 Suniva OPT 270-60-4-100 270W solar panels. The inverter is powered by two strings of 9 solar panels. DC Wire Pass thru box Nema 3R PVC junction box 9 Solar panels 2430 W DC
More informationX-Series Residential Solar Panels SunPower X-Series Residential Solar Panels X21-335-BLK X21-345 More than 21% Efficiency Ideal for roofs where space is at a premium or where future expansion might be
More informationSunny Family 2010/2011
Sunny Family 2010/2011 The Future of Solar Technology » SMA has the right solution for every application. Because each PV plant is unique Sunny Boy 1 to 5 kw Sunny Mini Central 5 to 11 kw Sunny Tripower
More informationAttachment A Design/Build Options - Photovoltaic Facility for FEMA Alternate Project February 16, 2016 Primary Contact Heath Mackay Namasté Solar 4571 Broadway Street Boulder, Colorado 80304 303-447-0300
More informationTuesday, March 22, Carolyn Price Town of Windsor
300 North St. Endicott NY 13760 www.etmsolar.com Phone: 607-785-6499 FAX: 607-786-3388 email: info@etmsolar.com Tuesday, March 22, 2016 Carolyn Price Town of Windsor Dear Carolyn, I have explored what
More informationMaximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops
Maximize your ROI Conext CL-60 String Inverter The ideal solution for decentralized power plants and commercial rooftops solar.schneider-electric.com 2016 Schneider Electric. All rights reserved. All trademarks
More informationPLUG-AND-PLAY ENERGY STORAGE SOLUTION
PLUG-AND-PLAY ENERGY STORAGE SOLUTION BENEFITS AT A GLANCE PLUG-AND-PLAY. ALL IN ONE The Y.Cube is a ready-to-install storage system, with all components inside a single enclosure. This off-theshelf solution
More informationTodae Solar s 1.22 MWp Rooftop Solar Photovoltaic Installation for Stockland Shellharbour, NSW.
Todae Solar s 1.22 MWp Rooftop Solar Photovoltaic Installation for Stockland Shellharbour, NSW. The Project Highlights Design Requirements and Technical Details Innovation and Best Practice The Project
More informationAMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T
SYSTEM OUTPUT SYSTEM VOLTAGE AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T 3640 LUMENS PER FIXTURE INPUT 4 VDC OUTPUT 1 VDC SYSTEM CERTIFICATION - ETL Listed UL 1598 - Certified to
More informationTSM-DC01A. The Solution NEW. linear performance warranty. Module can bear snow loads up to 5400Pa and wind loads up to 2400Pa
MONO MULTI DESIGN SOLUTIONS TSM-DC01 The Solution Module can bear snow loads up to 5400Pa and wind loads up to 400Pa Guaranteed power output (0~+3%) High performance under low light conditions (Cloudy
More informationSOLAR PHOTOVOLTAIC V-SYS ULTRA - FLEXI - ON FLOOR - ON TOP. MADE IN FRANCE
SOLAR PHOTOVOLTAIC ULTRA - FLEXI - ON FLOOR - ON TOP www.systovi.com MADE IN FRANCE PANELS THE QUALITY MADE IN FRANCE Our range of products combines power and aesthetics. Roof-integrated, on-top and on-floor
More informationThe brand you can trust.
Solar Proposal For SolarTime PURCHASE SUMMARY The brand you can trust. We are Professional Contractors with experience installing Solar Systems. We specialize in License Bonds, General Liability Cover
More informationETSU Solar Array. Suggestions for a potential solar array on campus. Scott Finney
ETSU Solar Array Suggestions for a potential solar array on campus Scott Finney May 11 th, 2014 Background: East Tennessee State University has an extremely active department of sustainability. This department
More informationTechnical specifications
KINGDOM OF SAUDI ARABIA THE SAUDI FUND FOR DEVELOPMENT ( SFD) ITB -207-7 Technical specifications Project name: Reconstruction, Furniture and Equipping of Three Schools Photovoltaic Solar System for Holly
More informationMinnesota Dept. of Commerce, Division of Energy Resources. Distributed Generation Workshop Interconnection Standards
Minnesota Dept. of Commerce, Division of Energy Resources Distributed Generation Workshop Interconnection Standards Presented by Michael Sheehan, P.E. October 11, 2011 Germans Solar Projected Cost Reductions
More informationSolar Seminar. July 21st, Barry Cinnamon
Solar Seminar July 21st, 2018 Barry Cinnamon Agenda 1. Company Overview 2. Solar Economics Cost of Electricity Solar Incentives Solar Costs Are You a Candidate? 3. Solar Technology PV Solar Shingles Battery
More informationTechnical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER
Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER To control the generated power of a PV system that is directly fed into the grid,
More informationConergy PH 185M 200M. Special Edition Australia. Specifications Photovoltaic modules
Specifications Photovoltaic modules Conergy PH 185M 200M Special Edition Australia The Conergy PH 185M 200M solar modules offer a multitude of possible uses at an attractive price/performance ratio. They
More informationSolutions for Profitable PV Power Plants
Solutions for Profitable PV Power Plants EN Cutting-Edge Applications for Utility-Scale PV Projects FINANCIALLY SOLID UP TO 99% AVAILABILITY GLOBAL SERVICE STRUCTURE ALL APPLICATIONS FUTURE-PROOF 100%
More informationThomas Alston Director of Business and Policy Development. Presented By N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257
Residential Solar Workshop May 7 th 2008 Thomas Alston Director of Business and Policy Development Presented By 1475 N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257 Workshop Agenda An Overview of
More informationCommercial Solar Opportunities. Kevin Moore Koch
Commercial Solar Opportunities Kevin Moore Koch WHY SOLAR? Environmental Reduce Carbon Footprint Financial Fixed utility costs Good ROI Strategic Showcase environmental leadership Reliable/Low Maintenance
More informationInformation Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program
Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program As part of our commitment to support renewable energy, Kissimmee Utility Authority
More informationShould I Get a Solar Array for my House? The Regulations, Available Equipment, and Benefits Steven Johnson
Should I Get a Solar Array for my House? The Regulations, Available Equipment, and Benefits Steven Johnson 1 Scope Explore the considerations in the decision to install a PV System on my house Limited
More informationDistribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world
Distribution division Solar Photovoltaic Catalogue Premier Plaan Smart solutions for the solar energy sector around the world IM60 Series Photovoltaic Modules Peak Power: 230-250 Wp FEATURES 60 poly-crystalline
More informationJEA Distributed Generation Policy Effective April 1, 2018
Summary This JEA Distributed Generation Policy is intended to facilitate generation from customer-owned renewable and non-renewable energy generation systems interconnecting to the JEA electric grid. The
More informationRPS TL-UL System. Solutions for the North American Solar Market
RPS TL-UL System Solutions for the North American Solar Market 2015/2016 Power, control and green solutions 3 RPS TL-UL System Photovoltaics is now offering the ULcertified RPS TL inverter series. Leveraging
More informationABB central inverters PVS to 2091 kva
SOLAR INVERTERS ABB central inverters PVS980 1818 to 2091 kva 01 ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators
More information3 Phase Power Systems - Designed for Canada
3 Phase Power Systems - Designed for Canada AC OUTPUT NESS-25kVA - Mobile NESS-50kVA - Mobile Units Rated AC Power Output 33 66 kw Maximum AC Power Output 33 66 kw AC Output Line Connection 4 - wire (L1-L2-L3-N)
More informationSolar Photovoltaic (PV) Design Considerations & Issues. By Paul M. Williams, President & CEO
Solar Photovoltaic (PV) Design Considerations & Issues By Paul M. Williams, President & CEO NEC Article 690 Solar Photovoltaic (PV) Systems The article consists of eight chapters. Chapters 2 through 4
More informationOUR PARTNERS. More: Please note: All product illustrations in this brochure may differ from the original.
PID KILLER. OUR PARTNERS More: www.padcon.com Please note: All product illustrations in this brochure may differ from the original. PID - WHAT'S THAT? A DEGRADATION CAUSED BY POLARIZATION AND LEAKAGE CURRENTS
More informationMichigan Public Service Commission Grid Tied Solar Photovoltaic
Michigan Public Service Commission Grid Tied Solar Photovoltaic Commissioner Orjiakor N. Isiogu The Value of Grid-Connected PV Value Components Photovoltaics Energy and Generation Offset of fuel and O&M
More informationRequirements for PV Inverters in Germany and USA
California Solar Business Delegation to Germany German American Chamber of Commerce Inc. October 24, 2007 Requirements for PV Inverters in Germany and USA Dr. Bernd Engel, Vice President Technology, SMA
More information+86(571) (571) (V4)
+86(571)-56260011 +86(571)-56075753 5 (V4) THE SOLAX INVERTER The solar inverter is a critical technological component that is the heart of any PV plant. A solar inverter or PV inverter, converts the variable
More informationSell Solar TODAY with Solar in a Box
Sell Solar TODAY with Solar in a Box Sell Solar TODAY with Solar in a Box Ready Solar 101 Photovoltaic Technology Solar in a Box! Product! Advantages Solar Growth Market Selling Solar in a Box! Pricing
More informationConsumer Guidelines for Electric Power Generator Installation and Interconnection
Consumer Guidelines for Electric Power Generator Installation and Interconnection Habersham EMC seeks to provide its members and patrons with the best electric service possible, and at the lowest cost
More informationSOLAR ENERGY KIT MODEL: SEM-CS3000
SOLAR ENERGY KIT MODEL: SEM-CS3000 Introduction: SITECNO solar energy kit is on-grid PV system, a complete solution which generates electrical energy for self-consumption and feed surplus energy in to
More informationJune 13, Dear Mr. Klauss,
A Photovoltaic and Energy Storage Consultancy June 13, 2014 Martin Klauss, Assistant Superintendent Business and Administrative Services Oak Park Unified School District OPUSD 5801 Conifer Street, Oak
More information/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE
Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic
More informationSchneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant
Schneider Electric PV Skid Optimized solar power conversion system tailored to enhance any North American PV power plant 1 PV Skid solution Integrated solution designed for optimal performance in any environment
More informationINTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY
INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY Table of Contents Chapter 1. Purpose and scope. Pg 3 Chapter 2. Application
More informationSMA Utility Power System
EN SMA Utility Power System Integrated. Reliable. Profitable. Worldwide. Profitability is key Facilitate your PV power plant business with SMA You want to realize PV projects with maximum profits and minimized
More informationRenewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group
Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group Table of Contents 1. Introduction... 1 2. Purpose... 1 3. Customer Eligibility...
More informationSolarMax P series The power package for residential solar plants
SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our
More informationProduct Catalogue. Europe
Product Catalogue Europe The best $/kwh value under the sun Trina Solar is a pioneering manufacturer of high quality photovoltaic modules. Vertically Integrated Founded in 1997, Trina Solar is a pioneering
More informationFRENCH BROAD ELECTRIC MEMBERSHIP CORPORATION RATE SCHEDULES
FRENCH BROAD ELECTRIC MEMBERSHIP CORPORATION RATE SCHEDULES Effective for Bills Rendered on or after April 1, 2017 Table of Contents Title Page Primary Residential (Rate Schedule A-17) 3 Secondary Residential
More informationABB central inverters ULTRA-750/1100/ kW to 1560kW
Solar inverters ABB central inverters ULTRA-750/1100/1500 750kW to 1560kW * ABB s utility-scale ULTRA inverters combine high efficiency with a wide input voltage range and multiple maximum power point
More informationABB central inverters PVS to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
More informationTECHNOLOGY, RESOURCES, AND POLICIES
INTRODUCTION TO SOLAR: TECHNOLOGY, RESOURCES, AND POLICIES Energy Design Conference 2018 By Paul Helstrom- Minnesota Power AGENDA Ò Introduction: Ò Overview: Solar Resource, Technologies, and policies
More informationPV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control
PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control User Manual SMC9-11TLRP-BA-en-30 TBEN-SMCTLRP Version 3.0 EN SMA Solar Technology AG Table of Contents Table of Contents
More informationMicrogrid Technology. Paul Newman Microgrid Sales Manager North America - West
Microgrid Technology Paul Newman Microgrid Sales Manager North America - West Agenda Microgrid Thin Film Advantage Energy Storage Microgrid Master Controller Case Study Cat Microgrid Solutions See official
More informationRenewable Energy Catalogue
2016 Renewable Energy Catalogue www.elliesrenewable.co.za About us... Since inception in 1979, our focus at Ellies has always been on providing quality products and exceptional service to you, the customer.
More informationSUNNY BOY 2000HF / 2500HF / 3000HF
SUNNY BOY 2000HF / 2500HF / 3000HF SB 2000HF-30 / SB 2500HF-30 / SB 3000HF-30 High Yields Safe Simple Communicative Maximum efficiency 96.3 % The best tracking efficiency with OptiTrac MPP tracking Shade
More informationEconomics and Barriers to Solar Photovoltaic Applications in Barbados
Economics and Barriers to Solar Photovoltaic Applications in Barbados Roland R Clarke PhD Clarke Energy Associates www.clarkeenergy@aol.com clarkeenergy@aol.com Presented to Alternative Energy: Pathways
More informationIEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE
AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE AUTHOR(S): Bypina Veerraju Chaudary, Andy Nguyen, Yang Xiaowu Page 1 of 14 1. INTRODUCTION This installation instruction manual provides information
More informationYour Needs. Our Technology.
Your Needs. Our Technology. Renewable Energy Solutions for Businesses Nationwide As a division of Ellies Electronics (Pty) Ltd, Ellies Commercial Solutions offers innovative solar solutions for any business
More informationCommercial Solar the next big wave in the PV industry? SPREE Seminar, UNSW Thursday 1st May 2014
Commercial Solar the next big wave in the PV industry? SPREE Seminar, UNSW Thursday 1st May 2014 SPREE Seminar, UNSW 1 May 2014, page 1 The questions that will be answered i. Who is epho Pty Ltd? ii. What
More informationConsiderations for Municipal Solar Projects. Ben Frevert Larsen Engineers November 16, 2016
Considerations for Municipal Solar Projects Ben Frevert Larsen Engineers November 16, 2016 Topic Areas Benefits of going green / solar Actions local governments can take Programs and incentives Implementation
More informationSun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.
Parameter Location: Afghanistan, Baglan (36 North; 68 East) Water temperature: 25 C Required daily output: 50 m³; Sizing for average month Dirt loss: 2.0 % Motor cable: 100 m Pipe type: - Total dynamic
More informationGet ready for rising energy challenges. This is where xstorage Home can help
xstorage Home Get ready for rising energy challenges More and more people, factories, businesses connect to the grid around the world. How can you be sure there will still be power for you and your family
More informationCOMPANY INTRODUCTION COMPANY MISSION COMPANY VISION
COMPANY INTRODUCTION Biotech fuels, established in 2012, is an energy Solutions provider operating through Pakistan and Offering services in solar and bio fuels sectors. The organization has worked countrywide,
More informationSolar Electric Systems for Multi-Tenant Units. Presenters
Solar Electric Systems for Multi-Tenant Units Pacific Energy Center Tuesday, October 21, 2008 Presenters Pete Shoemaker Renewables Education Coordinator Pacific Energy Center pjsy@pge.com Chuck Hornbrook
More informationWhat is Solarize Westchester?
What is Solarize Westchester? Solar. Simple. Together. Makes solar simple, affordable and accessible to Ossining and Briarcliff homeowners and commercial property owners. Model has been implemented across
More informationThe Future of Solar Technology
The Future of Solar Technology » Welcome to the SMA Product Guide. This new catalog contains the complete worldwide product offering from SMA. When selecting an inverter, be sure it is suitable for use
More informationABB central inverters PVS to 1000 kw
ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and end users who require
More informationX-SERIES SOLAR PANELS
[Type text] X-SERIES SOLAR PANELS UNMATCHED PERFORMANCE, RELIABILITY & AESTHETICS 21.5% efficiency Ideal for roofs where space is at a premium or where future expansion might be needed. Maximum performance
More information