Pow-R-Way III Busway Service and Solutions
|
|
- Sherman Stephen Pearson
- 5 years ago
- Views:
Transcription
1 Pow-R-Way III Busway Service and Solutions Capabilities Busway Field Measurement Services Final Field Fit Program Express Bus Program Busway Value Calculator
2 Burj Dubai World's tallest building under construction, powered by Eaton's Cutler-Hammer Pow-R-Way III Busway.
3 Busway Pow-R-Way III SERVICE AND SOLUTIONS Taking Busway to New Heights! As a leader in providing quality, cutting-edge electrical distribution equipment, Eaton understands the importance of offering superior service and product solutions to its customers. This is often the difference that places Eaton above other manufacturers of electrical distribution equipment. Cutler-Hammer Pow-R-Way III Busway is becoming the preferred means of connecting electrical equipment in power distribution systems, due to its electrical efficiencies and cost-saving characteristics. To help ensure projects are kept on schedule, Eaton s Busway Team offers the following services and solutions: Busway Field Measurement Services This service is ideal for any project where there is an increased potential for making measurement errors. Final Field Fit Program This program was established to effectively manage the dimensional uncertainties that are often inherent in busway layouts. Express Bus Program This expedited shipment program is designed to help meet the needs of accelerated job site completion schedules or to help get critical loads on-line and operating. Busway Value Calculator This unique software program allows the installer to compare the total installed cost of busway installations against traditional cable/ conduit installations. All of the above programs are outlined in further details. To take full advantage of these programs or to obtain additional information, please contact your local Eaton sales office. Taipei 101 World's current tallest complete building, powered by Eaton's Cutler-Hammer Pow-R-Way III Busway.
4 Busway Field Measurement Services It s Better with Busway! Eaton s Busway Measurement and Layout Don t Lose Sleep Over Your Busway Project! Leave the details to us! On-site measurement by experienced factory trained personnel Cost-efficient and guaranteed to fit Solutions for every application: New installations Final field fits Add to existing Coordinate between new or existing equipment Rely on Eaton s busway measurement and layout service for your most complex projects. This service is your way to save time and money.
5 The purpose of the factory measurement service is to measure and provide layout drawings for each bus run. We are there to take the worry out of laying out the busway and avoid mistakes in measuring and laying out the busway, which could cost you time and money. In order to make the most of our site visit, we have outlined what to expect from our service and what we need in the way of preparation before our visit / /16 Service 4 5/8 1st Floor Our on-site measurement personnel are factory trained and experienced with busway products. We use handheld laser distance measuring tools to save time and ensure an accurate measurement. One set price includes travel expenses, site visit and measurement, and layout drawings for your approval. Expedited approval drawings within 2 weeks from the site visit /2 F 2 6-3/ / Site Preparation The following information should be worked out before scheduling your on-site measurement: Are the walls, floor and other obstacles the busway will penetrate or be routed around in place for measurement? Are the termination points identified and in a fixed location? Where is your gear lineup? Will it be sitting on a pad? What are the utility requirements if applicable? Where is the transformer to be set? What are the on-site requirements and restrictions? (Minimum headroom, maximum height, etc.) Where is the busway being routed outside and throughout the building? What other trades are also occupying the area and where are they being routed? We will need the assistance of one person on the job site who is familiar with all of the above and can work with us for the day to complete the measurements for the busway layout. Scheduling To help ensure the best possible service, we only send engineers and technicians who are trained and experienced in busway measurements and layouts. As a result, we have a limited number of personnel available. Requests are fulfilled on a first come first serve basis. Please allow 2 weeks notice to schedule a site visit. We will accommodate expedited requests whenever possible. An additional fee will apply if service is required in less than 2 weeks. Guarantee Most variance in the layout dimensions can be accommodated with our Pow-R- Bridge coupling, which allows 1-inch adjustment per joint connection. Should there be a measurement error that exceeds this adjustment, we will provide a replacement piece in a timely manner at no additional charge. 1 1 Note This free replacement does not include changes made in the layout or site after the factory rep has completed the measurements. 2 8 F /4 MSB Rear EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Field Measurement Services 5
6 Final Field Fit Program Pow-R-Way III Low Voltage Busway The Exact Fit the First Time Eaton is dedicated to producing a quality product and delivering it on time. The Final Field Fit Program was established to effectively manage the dimensional uncertainties that are often inherent in busway layouts. This program has been successful for many years and it provides the assurance of an exact fit the first time. It allows for busway runs to be released for manufacture when certain dimensions are not yet determined. It also eliminates the costly delays that can occur when sections have to be remade in order to accommodate last-minute job site changes in routing. Benefits include: Exact fit the first time Eliminates incorrect pieces Facilitates on-time project completion
7 1. Customer Faxes Dimensions for F01 Final Field Fit piece shipped within 5 to 10 working days. 2. Details on Process Greenwood provides this information for customer reference: Drawing number Order number Phone number Fax number Customer must fill in this information before faxing to Greenwood: Final field fit piece dimension. Shipping information: Name Company name Phone number Fax number Date Other field fit items Requested shipping date What is a Final Fit Piece? A field fit section of busway is typically an elbow or a short section of feeder that is intentionally left out of a run for later shipment. It is most often a mutually agreed upon section between the customer and the plant. In Figure 1, the field fit piece is identified as item F01, a downward elbow flange. Upon release of the order, this item is kept on hold for field measurement. The contractor will install the busway (items A01 through A12) and is then able to obtain an exact dimension for the final field fit piece. In this case, the measurement for item F01 should be made from the top of SWGR 1 up to the outside edge of the busway (dimension A ) and from the outside edge of the busway back to the edge of the housing of item A12 (dimension B ). When Should the Program Be Used? If you are uncertain of the exact dimensions on long runs or if you have pathway obstructions that will require job site routing of the busway, this program can help you. Here s How the Final Field Fit Program Works 1. Review busway requirements with your Greenwood product engineer. Together, you can determine which piece should be field fit. Release all the busway except the field fit piece. (There is a limit to the number of field fit pieces that can be supplied, so please consult your Greenwood product engineer.) 2. The contractor installs the busway and measures the field fit piece dimensions. 3. The contractor can fax the dimensions directly to the Greenwood product engineer on the Final Field Fit Program Fax Sheet Figure 2. The contractor simply fills in the requested information and transmits the form. The Final Field Fit Fax Release Form is customized to each order and shipped to the job site with the busway. The field fit items will match the F items shown on the construction drawings provided by Eaton. It will also reference the Cutler- Hammer drawing number and General Order number. 4. The field fit piece will ship within 5 to 10 working days after receipt. Offset and combination offset fittings may take longer to ship. Also, if more than 5 field fit pieces release at the same time, the shipment lead-time may take longer than 5 to 10 working days. Contact the factory for lead-times. 1 2 A = B = Edge of Housing A12 (13 Min) B C L BUS T F01 A Final Field Fit Program Fax Release! Fax Direct to Greenwood factory. Ref. Drawing: G.O.#: Item #: Phone #: Fax #: Customer to provide dimensions indicated by letters on field fit section of busway. Edge of Housing "A" Dimension = "B" Dimension = B C L BUS Top of Gear 2 0 A (8.62 Min) 10 0 Name: Company: Phone #: Fax #: Date: List other field fit items released at this time: Requested Ship Date: A C L Cutout 20 0 Top of Switchgear T F Oppos 2 of A12 A12 Edge of Housing C A12 BUS (13 Min) B Hold F (8.62 min) A Swgr 1 Front A10 Standard ship lead-time is 5 to 10 working days from receipt of complete information. EATON CORPORATION Pow-R-Way III Busway Service and Solutions Final Field Fit Program 7
8 Express Busway Program Quick-Ship SM A Quick Dependable Solution Eaton s electrical business continues to be the leader in providing service and product solutions to its customers. When you need a complete run of busway fast to get critical electrical loads running or meet time-sensitive deadlines, Cutler-Hammer Express Bus is the solution.
9 Product Offering Indoor Plug-in Busway 800 to 2500 amperes copper Indoor Feeder Busway 800 to 2500 amperes copper Corner Joints Forward (right) Rearward (left) Upward Downward Tap Boxes End tap box Plug-in tap box Bus Plugs Fusible Circuit breaker Accessories End closer Wall/floor flange Hangers Program Highlights Eaton will ship 12 total pieces of busway in 5 working days or 24 total pieces in 10 working days after receipt of released order. Total pieces are inclusive of end tap boxes and corner joints. For pricing, special requests or needs, please contact your local Eaton sales office. Plug-in units and additional hangers are stocked and available in the warehouse. How the Program Works By using the electronic form in Outlook, it's quick and easy as Write in the catalog numbers and quantities of the pieces needed. 2. Write in and extend the pricing. Obtain book and net multipliers from your local sales office. 3. Fill out all the information in the electronic form on Outlook for EatonCare order entry. Fax in a copy of the distributor purchase order. Once received, your order will be entered in the system and shipped within 5 to 10 working days based upon the number of pieces ordered. Note: Order must be entered by your local Eaton sales representative. Pow-R-Way III Busway Feeder and plug-in indoor busway with copper conductors are available in 10-feet (3.0 m) and 6-feet (1.8 m) lengths. They can be used interchangeably without the use of special adapters or special splice plates, provided they are the same current and system rating. Pow-R-Way III is constructed with a lightweight and rugged, two-piece all-aluminum extruded housing, which is rated as a 50% ground path. Copper bus bars for plug-in applications have full-sized conductor tabs welded to their side edges to form the plug-in contact surfaces. Tabs are the same exact thickness as the conductors and are fully rated up to 800 amperes. Corner Joint Elbows When it comes to bends and turns in a bus run, the Pow-R- Way III corner joint is the most compact elbow in the industry. Given the complexity of today s industrial and commercial distribution systems, and the need to coordinate layouts with HVAC, plumbing and lighting requirements, space quickly becomes a critical factor. The Pow-R-Way III corner joint elbow can be installed in areas where traditional 90-degree elbows could never have been accomplished before. Due to its compact design, the corner joint also allows for layouts that provide optimum utilization of space. Critical section length that would normally be required for a traditional elbow leg length can now be dedicated to maximizing usable plug-in section length. The corner joint is as reliable as traditional elbows. It is seismically certified and exceeds the requirements of both the UBC and CBC (Zone 4). The corner joint is UL listed for indoor applications. Fittings and Accessories End cable tap boxes are available for all ratings in the Express Bus program. Plug-in cable tap boxes are also available and are listed in Catalog CA E, Section 17. One horizontal hanger will be included for every 10 feet (3.0 m) of busway. Please specify flatwise or edgewise. Additional Information Product Brochure BR E Technical Data TD E Distribution Catalog CA E Consulting Application Guide CA E Electrical Solutions Catalog CA E ABCs of Planning/Installation IM E EATON CORPORATION Pow-R-Way III Busway Service and Solutions Express Busway Program 9
10 UPWARD/DOWNWARD CORNER JOINTS Wire Ampere Rating Copper Upward Shown T F X LC X LC L C (X) Upward (X) Downward Inches mm Inches mm 3-Phase 3-Wire Housing Ground Phase 4-Wire Housing Ground FORWARD/REARWARD CORNER JOINTS C L C L C L X Y T F Forward Shown C L Wire Ampere Rating Copper (X) (Y) Inches mm Inches mm 3-Phase 3-Wire Housing Ground Phase 4-Wire Housing Ground END CABLE TAP BOXES Wire Ampere Rating Copper LC L W Tap Box Width Length Inches mm Inches mm 3-Phase 3-Wire Housing Ground Phase 4-Wire Housing Ground EATON CORPORATION Pow-R-Way III Busway Service and Solutions Express Busway Program
11 DANGER DANGER DANGER EXPRESS BUS: PLUG-IN BUSWAY EXPRESS BUS: FEEDER BUSWAY Wire Ampere Rating Copper Copper 10' 0" Plug-in Length 6' 0" Plug-in Length 10' 0" Feeder Length 6' 0" Feeder Length Catalog Number Catalog Number Catalog Number Catalog Number 3-Phase 3-Wire 800 BX08C3HP120I BX08C3HP072I BX08C3HF120I BX08C3HF072I Housing Ground 1000 BX10C3HP120I BX10C3HP072I BX10C3HF120I BX10C3HF072I 1200 BX12C3HP120I BX12C3HP072I BX12C3HF120I BX12C3HF072I 1600 BX16C3HP120I BX16C3HP072I BX16C3HF120I BX16C3HF072I 2000 BX20C3HP120I BX20C3HP072I BX20C3HF120I BX20C3HF072I 2500 BX25C3HP120I BX25C3HP072I BX25C3HF120I BX25C3HF072I 3-Phase 4-Wire 800 BX08C4HP120I BX08C4HP072I BX08C4HF120I BX08C4HF072I Housing Ground 1000 BX10C4HP120I BX10C4HP072I BX10C4HF120I BX10C4HF072I 1200 BX12C4HP120I BX12C4HP072I BX12C4HF120I BX12C4HF072I 1600 BX16C4HP120I BX16C4HP072I BX16C4HF120I BX16C4HF072I 2000 BX20C4HP120I BX20C4HP072I BX20C4HF120I BX20C4HF072I 2500 BX25C4HP120I BX25C4HP072I BX25C4HF120I BX25C4HF072I EXPRESS BUS: FITTINGS Wire Ampere Rating Copper Upward Corner Joint Downward Corner Joint Forward Corner Joint Rearward Corner Joint Catalog Number Catalog Number Catalog Number Catalog Number 3-Phase 3-Wire 800 BX08C3HAUCJI BX08C3HADCJI BX08C3HAFCJI BX08C3HARCJI Housing Ground 1000 BX10C3HAUCJI BX10C3HADCJI BX10C3HAFCJI BX10C3HARCJI 1200 BX12C3HAUCJI BX12C3HADCJI BX12C3HAFCJI BX12C3HARCJI 1600 BX16C3HAUCJI BX16C3HADCJI BX16C3HAFCJI BX16C3HARCJI 2000 BX20C3HAUCJI BX20C3HADCJI BX20C3HAFCJI BX20C3HARCJI 2500 BX25C3HAUCJI BX25C3HADCJI BX25C3HAFCJI BX25C3HARCJI 3-Phase 4-Wire 800 BX08C4HAUCJI BX08C4HADCJI BX08C4HAFCJI BX08C4HARCJI Housing Ground 1000 BX10C4HAUCJI BX10C4HADCJI BX10C4HAFCJI BX10C4HARCJI 1200 BX12C4HAUCJI BX12C4HADCJI BX12C4HAFCJI BX12C4HARCJI 1600 BX16C4HAUCJI BX16C4HADCJI BX16C4HAFCJI BX16C4HARCJI 2000 BX20C4HAUCJI BX20C4HADCJI BX20C4HAFCJI BX20C4HARCJI 2500 BX25C4HAUCJI BX25C4HADCJI BX25C4HAFCJI BX25C4HARCJI EXPRESS BUS: TAP BOXES & ACCESSORIES Wire Ampere Rating Copper End Cable Tap Box End Closer Wall/Floor Flange Catalog Number Style Number Style Number 3-Phase 3-Wire 800 BX08C3HAETRI BVD0156G01 BVD0299G01 Housing Ground 1000 BX10C3HAETRI BVD0156G02 BVD0299G BX12C3HAETRI BVD0156G03 BVD0299G BX16C3HAETRI BVD0156G05 BVD0299G BX20C3HAETRI BVD0156G06 BVD0299G BX25C3HAETRI BVD0156G08 BVD0299G08 3-Phase 4-Wire 800 BX08C4HAETRI BVD0156G01 BVD0299G01 Housing Ground 1000 BX10C4HAETRI BVD0156G02 BVD0299G BX12C4HAETRI BVD0156G03 BVD0299G BX16C4HAETRI BVD0156G05 BVD0299G BX20C4HAETRI BVD0156G06 BVD0299G BX25C4HAETRI BVD0156G08 BVD0299G08 Please specify voltage: X=1 208/120 volts X=2 480/277 volts X=3 600/347 volts X=6 600 volts Hangers: Vertical and horizontal hangers are available. For horizontal hangers, please specify Hook or Angle and Flatwise or Edgewise. Plug-in Units: For fusible and circuit breaker plug-in units, please see catalog CA E, Section 17. Dimensions: For physical dimensions, ratings and product details, please see Technical Data TD E. EATON CORPORATION Pow-R-Way III Busway Service and Solutions Express Busway Program 11
12 Busway Value Calculator Pow-R-Way III Low Voltage Busway The Advantages of Busway There are many definite advantages to busway over cable and conduit distribution systems: Less Man-hours for Installation Busway is engineered and built to fit your specific layout needs. It is shipped to the job site ready for installation. Busway can be installed quickly and efficiently with only 40% of the labor required to install a conduit and wire system. Compact Size Due to its sandwich style design, busway has a very compact cross-sectional area and therefore occupies far less space than multiple conduits. Reusable, Expandable, Flexible As distribution needs change, you can easily relocate existing busway runs or add new sections to extend bus runs into other areas of your facility. A Safe and Versatile Design Pow-R-Way III meets the requirements of UL, NEMA, CSA and IEEE. Additionally, Pow-R-Way III is seismically qualified to both the UBC and CBC, exceeding Zone 4 worst case levels. The conductor bars are totally enclosed in a nonventilated aluminum housing which provides the highest short circuit ratings in the industry today. All bus plugs are polarized to prevent improper installation and the plug-in outlets are rated as IP2X for finger safety to IEC 529. Lower Installed Cost The savings in labor can generate a total installed cost reduction of as much as 40% compared to a conduit and cable installation.
13 Busway Saves Time and Money Myth Busway is more expensive than cable and conduit. Fact With the higher wholesale costs of cable and conduit, busway is very competitive when comparing material costs. However, it is the reduction in the number of man-hours required for installation that provides a significantly lower installed cost with busway than with pipe and wire. Myth Busway requires accurate layout and measurements. That takes too much time and effort and leaves room for errors. Fact Accurate layouts can be done quickly with the help of Eaton s Cutler-Hammer Greenwood plant. Customer approval drawings are mailed 2 weeks after receipt of the order. The Final Field Fit Program provides the means to effectively manage the dimensional uncertainties that are often inherent in busway layouts. The savings realized with a busway installation should compensate for the time and effort required. Myth In the low to mid-range ( ampere) ratings, there are no savings. Fact Busway can be competitive at any rating. A number of variables determine the installed cost of a distribution system. Contact Eaton for application assistance. Evaluating a Comparison When you evaluate your own job comparison, try an aluminum or copper busway alternate against copper cable. As you can see from the table above, aluminum and copper busway required approximately 1/3 of the installation time. Pow-R-Way III has many features that are beneficial, such as Class B insulation, an integral housing ground, an isolated ground option and a 200% neutral option. Contact your Eaton sales engineer for more information. To learn more about Eaton s innovative Cutler-Hammer products and solutions call , for engineering services call , or visit THERE IS AN APPLICATION FOR BUSWAY IN EVERY MARKET Facility Type Application Busway Advantage High Rise Riser feeder busway with Lower installed costs and Construction plug-in sections to distribute more efficient distribution power at each floor. of power. Industrial Feeder busway for tie runs The versatility of busway Plant between switchgear and multiple provides the user with the load plug-in busway to feed individual processes. ability to easily expand the distribution system as needs change. Institutional Single load feeder busway The compact cross-sectional and plug-in busway to feed size of busway allows for the specific loads. maximum utilization of needed space. Commercial Main service entrance feeder Safe distribution of power busway and plug-in busway for with the added value of tenant feeds and distribution. tenant metering from IQ Energy Sentinel bus plugs Ampere Utility Connection 2000 Ampere Utility Connection Switchboard or Switchgear Machine A Busway Machine B Motor Control Center Machine C Myth Busway takes too long to get to the job site while pipe and wire is always available. Fact Our lead-times are more competitive than ever and Greenwood can handle most Quick-Ship requests to meet the project requirements. Switchboard or Switchgear Panelboard Panelboard Machine A Cable and Conduit Machine B Motor Control Center Machine C EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Value Calculator 13
14 Determine a Cost- Effective Solution The Busway Value Calculator has been developed to help customers determine if Cutler-Hammer Pow-R-Way III Busway or cable and conduit is the most cost-effective solution for any given application. This user-friendly tool does a side-by-side total installed cost comparison between busway and cable and conduit. With the lightweight, compact design of Pow-R-Way III Busway, there are significant labor cost savings resulting in an overall installed cost savings over cable and conduit systems. How It Works The Busway Value Calculator utilizes the NECA labor unit system to help calculate the labor costs associated with installing cable and conduit systems as well as busway systems. There are no hidden tricks and the user has full control of the comparison. While default pricing is included, all data, from the NECA labor unit values to material costs, can be adjusted to match your costs and efficiencies. This also allows you to see cost impacts as different variables change. Based upon your fully burdened labor rate and material costs, the calculator configures a material cost comparison, labor cost comparison and a total cost comparison as well as bills of material for both. Most selections may be made via drop-down menus. Once the ampere rating of the system is selected, the Busway Value Calculator automatically sizes the conduit and cable and determines the number of each per phase. This is done per NEC guidelines and tables. This may also be done manually within the program. The final comparison results may be printed in a report format or exported as a Word document and saved. Listed below is a cost comparison for a 1600 ampere tie run between two switchboards. The bill of material is for 300 feet, 3-phase, 4-wire with ground, eight elbows and two switchboard connections. Rigid conduit is used with 500 kcmil THHN copper cable. The fully burdened labor rate is set at $35.00 per hour. Sample Cost Comparison CONDUIT & CABLE METHOD Equipment Quantity Material Labor Total Cost 3 1/2" Rigid Steel Conduit 1500 ft. $14, $13, $28, Elbow(s) 40 $1, $3, $5, Bushing-Lock Nuts 10 $ $ $ Pull Boxes 3 $96.00 $ $ Trapeze Hangers 39 $ $2, $2, Conduit Channel Clamps 105 $ $ $ kcmil THHN Wire 6320 ft. $30, $9, $40, kcmil Ground Wire 1580 ft. $3, $1, $5, Compression Lugs 50 $ $1, $2, Method Total $86, BUSWAY METHOD Equipment Quantity Material Labor Total Cost 1600 Ampere Feeder Busway 300 ft. $50, $9, $60, Busway Elbow(s) 8 $2, $ $2, Busway Gear Flange 2 $ $ $ Busway Hanger Rods 39 $13.00 $ $ Method Total $64, Note: All busway components are based on indoor, copper design with 50% integral housing ground. 14 EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Value Calculator
15 Additional Comparisons In addition to the installed cost comparison, the Busway Value Calculator does a space savings comparison and voltage drop comparison between busway and cable and conduit systems. Space Savings With the compact design of the Pow-R-Way III Busway, it occupies far less space than that of multiple conduits. In the sample comparison shown, conduit would occupy 92 square inches of space along the run compared to only 32 square inches for Pow-R-Way III Busway. Voltage Drop Efficiencies With Pow-R-Way III Busway only having one or two conductors per phase and the Pow-R-Bridge joint design, its voltage drop is much lower than that associated with cable. In the sample comparison shown, the line-to-line voltage drop for cable is 39.1 volts at the end of the run. Pow-R-Way III Busway only has an 8.8 drop in voltage at the end of the run. This means much lower losses allowing a more efficient use of energy. Volts Cable Space Savings Voltage Drop Comparison Busway Conductor System For a free copy of the Busway Value Calculator software, please contact your local Eaton sales office. Also look for our newly updated Web-based version to be made available in the near future. EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Value Calculator 15
16 Eaton s electrical business is a global leader in electrical control, power distribution, uninterruptible power supply and industrial automation products and services. Eaton s global electrical brands, including Cutler-Hammer, Powerware, Holec and MEM, provide customer-driven PowerChain Management solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical and OEM markets worldwide. Eaton Corporation is a diversified industrial manufacturer with 2006 sales of $12.4 billion. Eaton is a global leader in electrical systems and components for power quality, distribution and control; fluid power systems and services for industrial, mobile and aircraft equipment; intelligent truck drivetrain systems for safety and fuel economy; and automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety. Eaton has 62,000 employees and sells products to customers in more than 125 countries. For more information, visit Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA United States 877-ETN-CARE ( ) Eaton.com PowerChain is a trademark of Eaton Corporation. Cutler-Hammer and Pow-R-Way III are registered trademarks of Eaton Corporation. UL is a registered trademark of Underwriters Laboratories Inc. CSA is a registered trademark of the Canadian Standards Association. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. Uniform Building Code (UBC) is a trademark of the International Conference of Building Officials (ICBO). IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers, Incorporated. Outlook is a registered trademark of Microsoft Corporation Eaton Corporation All Rights Reserved Printed in USA Publication No. BR E / Z5761 August 2007
Pow-R-Flex low ampere busway
Pow-R-Flex low ampere busway Commercial Industrial Telecommunications Data centers Research Light manufacturing Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway provides
More information6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions
.1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More informationPow-R-Way III Low Voltage Busway. Product Focus. Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of a Global Marketplace
Pow-R-Way III Low Voltage Busway Product Focus Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of a Global Marketplace Pow-R-Way III Low Voltage Busway 1 Eaton s electrical business
More information100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E
100-Ampere Busway Technical Data TD01701002E Effective November 2005 New Information Elbow, Busway and Cable Tap Box Contents General Information.............................. 2 Connections...............................
More informationPow-R-Way III low voltage busway. Meeting the needs of a global marketplace
Pow-R-Way III low voltage busway Meeting the needs of a global marketplace Pow-R-Way III low voltage busway Eaton s electrical business has combined the requirements of NEMA, UL and CSA into one design
More informationBusway Construction. Bus Bars
Busway Construction Bus Bars A better understanding of what busway is can be gained by examining its construction. A typical Siemens Sentron busway section has three or four formed aluminum or copper bars
More informationXB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type
XB IEC Terminal Blocks Screw Type Spring Cage Type Insulation Displacement Connection Type 2 XB IEC Terminal Blocks. Versatility, quality, and reliability. Sometimes it s the little things Eaton knows
More informationBUSWAY Low Voltage (Pow-R-Flex)
BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and
More informationUnitole UP kv Primary substations Motor control centres
Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton Holec creates power-engineering
More informationMP-4000 Motor Protection
MP-4000 Motor Protection Product Focus EATON CORPORATION 1-800-525-2000 Eaton.com 1 Multi-function motor protection Introducing Eaton s Cutler-Hammer MP-4000 motor protection relay. Eaton s Cutler-Hammer
More informationCapabilities Brochure
Eaton Corporation - Electrical Division Capabilities Brochure Australia and New Zealand An Introduction to Eaton Corporation Eaton Corporation is a diversified power management company with 2010 global
More information6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions
.1 Low Voltage Busway Features, Benefits and Functions Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements
More informationBusway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by
Siemens STEP 2000 Course Busway It's easy to get in STEP! Download any course. Hint: Make sure you download all parts for each course and the test answer form. Complete each chapter and its review section
More informationWavePro LT Busway Cost effective solution for electrical distribution
Busway Cost effective solution for electrical distribution 1/ Busway 20 year life Mylar wrap insulation Up to 5000A for both Feeder and Plug-In IP 40/42/55/65 protections 50% AL housing ground with internal
More informationIntroduction. Upon completion of Busway you should be able to:
Table of Contents Introduction...2 Distribution Systems...4 Busway Purpose and Definition...6 Sentron Busway...10 Types and Application...11 Design Standards and Ratings...13 Circuit Protection...18 Busway
More informationSPX9000 FR10 FR12 Adjustable Frequency Drives
Installation Manual New Information MN04003018E For more information visit: www.eatonelectrical.com SPX9000 FR10-FR12 Adjustable Frequency Drives Important Notice Please Read The product discussed in
More information6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions
.1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design
More informationPowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION
PowerWave Bus System tm For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION PDI PowerWave Bus System tm : designed specifically for the Critical Power Market The
More informationUnitole UP kv Primary substations Motor control centres
Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton creates power-engineering
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationW-VACi MV circuit breakers
IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv W-VACi MV circuit breakers A safe choice from a reliable source High-performance Safe and reliable Compact and cost effective Environmentally
More informationFlexible, Customizable Power Solutions for Mission Critical Success
Flexible, Customizable Power Solutions for Mission Critical Success The most critical decision, for mission critical facilities. By their very nature, mission critical and data center facilities are extremely
More informationXIRIA Green, Smart, Compact solution
Green, Smart, Compact solution Automotive Powering business worldwide Aerospace Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing world. We help
More informationXiria 24 kv Ring Main Unit
Xiria 24 kv Ring Main Unit Product Focus High operational safety Maintenance-free Safe visible earthing and position indication Environmentally friendly Compact Suitable for substation automation Vacuum
More informationLow voltage busway Pow-R-Flex low ampere busway
Contents Description Page Description Page General information........................ 2 General description........................ 2 Standards................................ 2 Conductor details..........................
More informationSafety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers
Series G Moulded Case Circuit Breakers Product Focus Up to 690 Vac 18kA to 100kA Icu 16-2500 Amperes IEC 60947-2 Safety, Reliability and Performance verified with the KEMA KEUR mark Safety, Reliability
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationOverview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions
Overview Brochure Integrated Power Distribution Medium Voltage Assembly Solutions Medium voltage assembly solutions Eaton, a premier leader in manufacturing power distribution and power protection equipment
More informationFlexible. Intelligent. Trendsetting.
www.eaton.com www.moeller.net Flexible. Intelligent. Trendsetting. The easy way to connect. Product Information Motor-protective circuit-breaker PKE with electronic wide-range overload protection. Obliged
More informationGE Consumer & Industrial Electrical Distribution. Spectra Series Busway. Busway vs. Wire & Conduit. imagination at work
GE Consumer & Industrial Electrical Distribution Spectra Series Busway Busway vs. Wire & Conduit imagination at work Heavy-Duty Power In a Light Package Spectra Series Busway makes the most sense for commercial
More informationData Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?
Data Bulletin March 2002 Lexington, KY, USA Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT? Table 1: Insulation Type Figure 1: Figure 2: Ampacity of a 1/0
More informationSelection and Application Guide. busway system. Cost-effective Power Distribution Compact Design
Selection and Application Guide busway system XJ-L Cost-effective Power Distribution Compact Design Specifications New for 2007..400A XJ-L Busway XJ-L Busway is available up to 400A. First introduced in
More informationXiria 12 kv Ring Main Unit in IEC and ENATS design
Xiria 12 kv Ring Main Unit in IEC and ENATS 41-36 design Product Focus High operational safety Maintenance-free Safe visible earthing and position indication Environmentally friendly Compact Suitable for
More informationPut the Power in Your Hands
Put the Power in Your Hands StarlineTrack Busway... STARLINE Track Busway is quickly becoming the industry standard for power distribution systems. Introduced in 1988, this innovative system is a modular,
More informationFlexible, Customizable Power Solutions for Mission Critical Success
Flexible, Customizable Power Solutions for Mission Critical Success The most critical decision, for mission critical facilities. By their very nature, mission critical and data center facilities are extremely
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationO & M Manual for the EATON Generator Ready Loadcenter
O & M Manual for the EATON Instructional Booklet New Information Description Page 1. Introduction............................... 2 2. Receiving, Handling, and Storage................ 4 3. Equipment Description........................
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationEATON Corporation David May J.C. Moots
This is a photographic template your photograph should fit precisely within this rectangle. EATON Corporation David May J.C. Moots Specifiers' Properties information exchange AEC-ST 2008 Eaton Corporation.
More informationwww. ElectricalPartManuals. com Section 13 Switchgear Low Voltage
Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI
More informationGet smart. Reduce energy consumption
MEM Electrical sub-distribution Lighting and power metering solutions L2 building regulations compliant Single phase MCB boards Three phase MCB boards MCCB panelboards Get smart. Reduce energy consumption
More informationHIGH POWERBAR COPPER UL857
HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 E+I Engineering s High Powerbar (HPB) UL857 range is a 600 Volt totally encased, non-ventilated, low impedance busduct. The range is available from
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationInnovac SVS/08 - SVS/ kv modular switchgear
Innovac SVS/08 - SVS/ 3.6-4 kv modular switchgear Product Focus Epoxy resin insulated switchgear in sheet steel enclosure with vacuum interrupters Total reliability in switching, metering and distributing
More informationCity of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)
City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems
More informationTradition. Technology. Innovation.
Tradition. Technology. Innovation. 2 Tradition. Technology. Innovation. 50433 IEM CorpBror1.indd 2 4/3/15 2:41 PM Today, IEM has expanded beyond Silicon Valley to supply specialized electrical equipment
More informationTO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control
CEP7 Solid-State Overload Relay for Motor Control Centers and Technical Data Description Page Product Description.............................................. 2 Specifications...................................................
More informationFlexible, Customizable Power Solutions for Mission Critical Success
Flexible, Customizable Power Solutions for Mission Critical Success The most critical decision, for mission critical facilities. By their very nature, mission critical and data center facilities are extremely
More informationIntroduction. Features. Intelligent Technologies Motor Control Center Structures
Intelligent Technologies Technical Data New Information Description Page Intelligent Technologies General............................................. 2 s.......................................................
More informationPOWERBUS 225 Busway and Plug-In Units
Busway and Plug-In Units Class 5600 CONTENTS Schneider Electric Brands Description Page Product Descriptions.................................................. 3 POWERBUS 225 Busway System.....................................
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationPDI PowerWave 2 Bus System
1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening, low voltage, vertical or horizontal power busway distribution system. System
More informationSpecification made simple for selective coordination in a compact size
Quik-Spec family of circuit protection solutions BUSSMANN Specification made simple for selective coordination in a compact size SERIES The Quik-Spec Coordination Panelboard (QSCP) simplifies selective
More informationSelection and application guide
Selection and application guide Integrated Power Systems Switchboards www.usa.siemens.com/switchboards Integrated Power Systems Switchboards Contents General Product Information 2-3 General Layout Information
More informationPOWERCON CORPORATION
POWERCON CORPORATION 38,000 VOLT METAL-CLAD SWITCHGEAR BROCHURE #PC-041 ELECTRONIC VERSION CREATED: 6/30/96 Powercon Corporation P.O. Box 477 1551 Florida Avenue Severn, Maryland 21144 Baltimore: 410-551-6500
More informationPower Mod. Introduction.
Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationA. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.
16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to
More informationBulletin VX05 VANEAXIAL FANS
Bulletin VX05 VANEAXIAL FANS Models: VXD, VXB Direct Drive and Belt Drive s VXD/VXB Introduction CERTIFIED RATINGS AMCA Certification UL Certification PennBarry certifi es that the Vaneaxial fans shown
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationEXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS
EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS EASY TO INSTALL, OPERATE AND MAINTAIN. PlexPower Panelboards use circuit breaker modules that provide explosionproof protection
More informationEZTray. Cable Management Made Easy
EZTray Cable Management Made Easy PRESENTATION Introduction:.................................. 3 EZ Tray: The Tray That Saves You Time!.............. 4-5 EZ Tray: The Innovative Cable Management Solution....
More informationMidwest Dry Type Transformers
Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase
More informationPowering business worldwide
Powering business worldwide Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing world. We help our customers worldwide manage the power they need
More informationThe easiest and fastest way to select and specify the right fuse
Fuses Made Simple BUSSMANN SERIES The easiest and fastest way to select and specify the right fuse Fuse selection made simple Fuses Made Simple with Bussmann series fuses Three tiers of protection help
More information1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".
SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,
More informationCustomer Requirements Downtown Secondary Network Service
Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard
More informationReliably Switching Highest Currents up to 2200 A
www.moeller.net Reliably Switching Highest Currents up to 2200 A Product Information DIL M contactors DIL H contactors High Rated Contactors DIL: Switching High Currents Reliably Contactors DIL M from
More informationSECTION 500 METERING AND ASSOCIATED EQUIPMENT
SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.
More informationW-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter
IEC Withdrawable Vacuum Contactor-Fuse Combination Truck 7.2kV and 12kV Product Guide W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter Automotive Powering business
More informationElectrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy
Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy Case study A Wisconsin-based manufacturer of chiller equipment needed to improve the SCCR of their standard
More informationSupply-Side PV Connections
Perspectives on PV Supply-Side PV Connections by John Wiles Plan reviewers and inspectors throughout the country are seeing increasing numbers of supply-side connected utility interactive photovoltaic
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationFeatures, Benefits and Functions
-8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
More informationBolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K
Bolted Contact Pringle Switch Cutler-Hammer Bolted Contact Pringle Switch Effective Date March 16, 2009 Replaces TD.02.56.01.T.K 12 Bolted Contact Switch Offering Features 600 volt CSA 480 volt UL DC ratings
More informationATLV MaxSG. Low Voltage Metal Enclosed Switchgear
ATLV MaxSG Low Voltage Metal Enclosed Switchgear ABB, INC. Product General Description MaxSG Switchgear ABB MaxSG switchgear is a further continuation in the development of innovative products from ABB,
More informationBusway Products Medium Voltage Busway Nonsegregated Phase Bus
Busway Products Pow-R-Way III Upward Elbow.1 Pow-R-Way III Busway Product Description........................................... 2 Features, Benefits and Functions................................ 12 Standards
More informationModular Standardized Electrical and Control Solutions for Fast Track Projects
Modular Standardized Electrical and Control Solutions for Supporting fast track projects ABB is the leading supplier of electrical and control equipment for power plants. The company offers a comprehensive
More information4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...
.5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,
More informationGE Industrial Solutions. Spectra Series * Busway
GE Industrial Solutions Spectra Series * Busway . All the muscle without the weight. GE engineers have broken the weight barrier with Spectra Series Busway. Its computerdesigned, all-aluminum housing is
More informationDesign Standards NEMA
Design Standards Although several organizations are involved in establishing standards for the design, construction, and application of motor control centers, the primary standards are established by UL,
More informationFuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.
Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,
More informationCutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers
Cutler-Hammer Installation Instructions for the Digitrip OPTIM 550 3-Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Table of Contents Description Page 1.0 General Information......................1
More informationRV Park Equipment Product Focus. Power Pedestals Distribution Equipment
RV Park Equipment Product Focus s Distribution Equipment Eaton Corporation RV Park Hookups Product Eaton offers a complete portfolio of electrical products for your RV project including pedestals, distribution
More informationIT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus
IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus Control and Expanded Functionality for Intelligent Technologies (IT.) See How IT. All Works Together A Complete Family of IEC
More informationNew Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home
New Products for Integrated Electrical Systems/Questions and Answers/Resources necdigest Seen in necdigest TM NFPA s Official NEC Magazine The Voice of Authority www.necdigest.org Feb/March 2002 Volume
More informationPlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationQuick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers
uick selector reference guide Pow-R-Stock panelboards, safety switches, and transformers Table of contents Pow-R-Stock panelboards uestions to ask... 5 Catalog numbering... 6 Interiors, EZ boxes, and trims...
More informationPOWERPLEX PANELBOARD 1
1 POWERPLEX PANELBOARD 2 ADVANCING PANELBOARD TECHNOLOGY WITH COMPONENT LEVEL PROTECTION. Introducing the PowerPlex Panelboard. Appleton's PowerPlex Panelboard changes the face of hazardous location panelboards
More informationA. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.
16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional
More informationConduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems
Conduit and Wire Must be scrapped whenever reconfiguration of the electrical layout is needed. Many runs may be needed for applications with a high volume or high density of electrical loads. It is labor
More informationCombining the IQ250/260 & Power Xpert Gateway 600A equals intelligent hardware.
PowerChain Management solutions Application note Combining the IQ250/260 & Power Xpert Gateway 600A equals intelligent hardware. Measure, document and verify energy usage. IQ250/260 Introduction What do
More information