TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE

Size: px
Start display at page:

Download "TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE"

Transcription

1 TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS P RUN CAPACITOR SINGLE P238 MFD PART NUMBER SIGNIFICANCE MFD NON-PCB DIELECTRIC FLUID UL APPROVED CURRENT INTERRUPTER MULTIPLE ELECTRICAL TERMINALS MAX. CAN HEIGHT (in.) VAC R = ROUND NO LETTER = OVAL 1 = 2 = 3 = = = 6 = 7 = = 9 = 370 VOLT SINGLE P P P P P P P P P P P P P P P P VOLT SINGLE P P P P P P P P P P P P P P P P P VOLT SINGLE P DUAL COMP. MFD P239 FAN NON-PCB DIELECTRIC FLUID UL APPROVED CURRENT INTERRUPTER MULTIPLE ELECTRICAL TERMINALS MAX.CAN HEIGHT (in.) 370 VOLT DUAL P P P P P P P P P P P P P P P P P P P P P P P P P P P P P VOLT DUAL P P P P P P P P P P P P P P P P P P

2 RUN CAPACITORS ROUND MOTOR RUN CAPACITORS TOTALINE CAPACITORS P PART NUMBER SIGNIFICANCE RUN CAPACITOR MFD VAC R = ROUND 1 = 2 = 3 = = = 6 = 7 = = 9 = SINGLE DUAL NON-PCB DIELECTRIC FLUID UL APPROVED CURRENT INTERRUPTER MULTIPLE ELECTRICAL TERMINALS NON-PCB DIELECTRIC FULID UL APPROVED CURRENT INTERRUPTER MULTIPLE ELECTRICAL TERMINALS P240 MFD MAX CAN HEIMGHT (in.) 370 VOLT SINGLE P R P R P R P R P R P R 440 VOLT SINGLE 60 - P R 40 - P RS P241 MFD MAX.CAN COMP. FAN HEIGHT (in.) 370 VOLT DUAL P RS P R P R P R P R P R P R P R P R P R P R P R P R 440 VOLT DUAL P R P RS P RS 275

3 START CAPACITORS (with bleed resistor) PART NUMBER SIGNIFICANCE P TOTALINE CAPACITORS START CAPACITOR MFD VAC 1 = = = = = = 4 = = 5 = 250 P242 MFD RANGE DIAMETER (in.) LENGTH (in.) 115 VOLTS P VOLTS P P P P P P P P P P P P P P P P P P P P P P P P P P P P VOLTS P MFD RANGE DIAMETER (in.) LENGTH (in.) 250 VOLTS P P P P * P P P P P P P P P * P P P P P P P P P P P P * 220 volts. 330 VOLTS P P * P * P * P P P P P P * P P P P P P P P P P P P P * 320 volts. 276

4 TOTALINE CAPACITOR/ACCESSORIES START KIT P243 Totaline start kits are for use with PSC compressors requiring additional starting torque. Totaline start kits are available for the most popular Copeland, Tecumseh, Bristol, and Carlyle compressors. The kit contains the following: START CAPACITOR WIRE KIT (1) Black Wire 54 IN. Long START RELAY (1) Brown Wire 16 IN. Long (1) Blue Wire 38 IN. Long (1) Brown Wire 30 IN. Long END CAP BRACKET INSTRUCTION SHEET START CAPACITOR START RELAY MFD RANGE VOLTS RATING MAX OPER. VOLTS PICKUP VOLTS DROPOUT VOLTS AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P WIRE KIT P244 An assortment of wires to be used to connect a start relay and start capacitor to a unit for hard start capability. : P : P (1) Black Wire 44 IN. Long (1) Black Wire 54 IN. Long (1) Blue Wire 22 IN. Long (1) Brown Wire 16 IN. Long (1) Black Wire 14 IN. Long (1) Blue Wire 38 IN. Long (1) Yellow Wire 29 IN. Long (1) Brown Wire 30 IN. Long BRACKET END CAP BOOT START THERMISTER P248 STRAP P249 This 25 OHM PTC device provides additional starting torque for compressors. Connects in parallel to run capacitor : P P245 P246 P247 PART NAME USE WITH CAPACITOR : Start Capacitor Bracket 3-3/8 Long P Start Capacitor Bracket 4-3/8 Long P Capacitor End Cap 1-13/16 Diameter P Capacitor End Cap 2-1/16 Diameter P Capacitor End Cap 2-9/16 Diameter P Terminal Boot Single Oval Top Outlet P Terminal Boot Single Oval (2) Side Outlets P Terminal Boot Single Round P Terminal Boot Dual Oval P PART NAME USE WITH CAPACITOR : Mounting Strap 1.21 x 2.06 Oval P Mounting Strap 1.81 x 2.81 Oval P Mounting Strap 1.87 x 3.56 Oval P Mounting Strap 15 FIT ALL P Wrap Around Mounting Strap.63 x 2.05 Oval P Wrap Around Mounting Strap.91 x 2.80 Oval P Wrap Around Mounting Strap 1.58 Wide.95 x 3.59 Oval P

5 RELAYS RELAY APPLICATION DATA CONTROL RELAYS The main function of any relay is switching electrical circuits. Selection depends primarily on load characteristics which should be matched closely to the rating of the relay to avoid contact point deterioration. Relay ratings in amperes are listed in this brochure as inductive or resistive. Inductive Rating - applies to switching of motors and coils for contactors and relays. Resistive Rating - applies to switching of electric resistance heating elements. The relays shown on the following pages have been classified into two major categories, power rated relays for intermediate loads and pilot duty relays for low level switching. Pilot Duty Relays: Contacts are made of a fine silver alloy and are shaped and sized for low level current switching. The fine silver alloy contact provides a very low surface resistance for the best possible contact life. Use on higher or intermediate loads would melt the relay points causing a welded contact. Power Rated Relays: Contacts are generally made of silver cadmium oxide with a very high surface resistance. They are sized larger than pilot duty contacts to handle switching of intermediate loads during which a slight arc may occur. Due to being larger in size, they must operate with a lower unit pressure on the contacts and, for satisfactory performance, depend on the make-break arc process to break down the resistance of deposits formed on the contacts. Use of this type relay to switch low level loads is not recommended by Carrier or its suppliers due to the lower contact pressure, the high surface resistance of the contacts and the absence of the slight arc during switching. A continuing build-up of deposits on contact points will cause a non-conductive surface and a failed relay. In some instances a power rated relay will fail to switch a pilot duty load on initial use. For reliable relay operation, it s advisable not to use a power rated relay for a pilot duty relay or vice versa. ARRANGEMENT S SPST DPST DPST TPST TPDT FPDT (1) (4) (6) (8) SPST (2) (5) DPST DPDT TPST (10) (11) SPDT (9) (7) (3) (DB) - Indicates contacts are Double Break type in which stationary contacts are connected by a bridging bar. Two examples of a double break arrangement are shown below with contacts #1 and #2 stationary. Both are SPST, normally closed, double break arrangements Connects 1 to 2 only Connects 1 and 2 to 3 278

6 FAN & POWER RELAYS TOTALINE RELAYS GENERAL PURPOSE RELAY Dependable, low cost solution for air conditioning and heating switching. Insulating Material - Constructed of UL recognized Class B insulating material Temperature Range to 150 Fahrenheit P262-A * Fan control * Appliances * Business Machines * Photoelectric control and general purpose switching SINGLE POLE FAN RELAYS- SIMILAR TO TYPE 84 FAN RELAYS RATING 125/250 VAC DESCRIPTION 8 AMPS (IND.) 16 AMPS (RES.) SPST, 24 V COIL P CONTINUOUS SPST, 110/240 V COIL P AMPS INRUSH SPST, 208/240 V COIL P AMPS (IND.) 8 AMPS (RES.) SPDT, 24 V COIL P CONTINUOUS SPDT, 110/120 V COIL P AMP INRUSH SPDT, 208/240 V COILS P TWO POLE FAN RELAYS TERMINALS TERMINALS DESCRIPTION POWER POWER 24 V COIL P POWER POWER 110/240 V COIL P POWER POWER 208/240 V COIL P POWER PILOT 24 V COIL P POWER PILOT 110/240 V COIL P POWER PILOT 208/240 V COIL P PILOT PILOT 24 V COIL P PILOT PILOT 110/240 V COIL P PILOT PILOT 208/240 V COIL P P262-B * Vending machines * Appliances * Safety control * Fan control * Heating * Air conditioning and general purpose switching HEAVY DUTY FAN RELAYS ARRANGEMENT DESCRIPTION SPDT - NO 24 V COIL P SPDT - NO 24 V COIL P SPNO - SPNC 24 V COIL P

7 TOTALINE START RELAYS TOTALINE RELAYS/ACCESSORIES SINGLE POLE, NORMALLY CLOSED RELAYS TOTALLY ENCLOSED S RATED FOR A MAXIMUM ARC RUPTURING CAPACITY AT 600 VAC AND UNDER 1/4 IN. QUICK CONNECT TERMINALS G.E. 3ARR3 TYPE AND RBM TYPE 50/60 Hz ARRANGEMENT : P c 2-1/4 H x 2-1/4 W x 2-7/16 D RATING PICKUP VOLTS DROPOUT VOLTS MAX. OPER. VOLTS 35 Amp P Amp P Amp P Amp P Amp P Amp P * 50 Amp P Amp P Amp P Amp P * 50 Amp P Amp P * 50 Amp P * 50 Amp P Amp P * TOTALINE WIRE KIT An assortment of wires to be used to connect a start relay and start capacitor to a unit to obtain hard start capability. : P : P (1) BLACK WIRE 44 IN. LONG (1) BLACK WIRE 54 IN. LONG (1) BLUE WIRE 22 IN. LONG (1) BROWN WIRE 16 IN. LONG (1) BLACK WIRE 14 IN. LONG (1) BLUE WIRE 38 IN. LONG (1) YELLOW WIRE 29 IN. LONG (1) BROWN WIRE 30 IN. LONG P

8 TOTALINE RELAYS/ACCESSORIES RBM TYPE 75 RELAYS POWER DUTY APPLIANCE RELAY OPERATES IN ANY POSITION TERMINALS ARE SCREW TYPE ARRANGEMENT : DPST P /2 H x 2-1/2 W x 3-3/16 D (5) RATING (FLA) COIL INDUCTIVE TERMINAL VOLTS ARRANGEMENT* 120 V 240 V 120 V 240 V DPST 5 LEADS HN61VA067 *See contact arrangement diagram. RBM TYPE RELAYS 84 AND 184 BANTAM RELAY DESIGNED FOR COMPACTNESS TOTALLY ENCLOSED OPERATES IN ANY POSITION 1/4 QUICK CONNECT TERMINALS ARRANGEMENT S: (1) SPST (3) SPDT (4) DPST P /16 H x 1-1/2 W x 2-7/16 D POWER DUTY RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 120 V 240 V 120 V 240 V DPST 4 HN61KQ SPDT 3 HN61KJ250** SPDT 3 HN61KJ SPST 1 HN61KA SPDT 3 HN61KJ DPST 4 HN61KQ121 *See contact arrangement diagrams. **HN61KJ024 same as HN61KJ250 but with screw terminals. PILOT DUTY RATING (FLA) COIL VOLTS INDUCTIVE ARRANGEMENT* /250 V 125 V 24 SPDT 3 HN65KJ V, V 277 V 24 DPST 4 HN61KK /250 V 125 V 240 SPDT 3 HN65KJ015 *See contact arrangement diagrams. 281

9 TOTALINE RELAYS/ACCESSORIES RBM TYPE RELAYS 91 & 192, HONEYWELL TYPE RELAYS R4222 & R8222 SEMI-ENCLOSED CONSTRUCTION 1/4 IN. QUICK CONNECT TERMINALS THE SINGLE AND DOUBLE POLE RELAYS MAY BE USED WITH PLUG-IN RECEPTACLE PACKAGE 48DA ARRANGEMENT S: TPDT P252 SPDT SPST (1) (3) (6) DPST (7) DPDT (8) TPST (10) 2-1/4 H x 2-1/8 W x 1-7/8 D POWER DUTY RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 120 V 240 V 120/240/277 V SPST 1 HN61KA /25/25 24 SPST 1 HN61KA /25/ SPDT 3 HN61DJ V** 480 V** V 24 DPDT 7 HN61KK V 24 DPDT 7 HN61KK V 120 DPDT 7 HN61KK V 240 DPDT 7 HN61KK913 *See contact arrangement diagrams. **480 V rating applies only to HN61KK066. PILOT DUTY RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 125/250 V 277 V V 3A 24 SPST 1 HN61DA VA 3A 24 DPDT 7 HN61KK VA 3A 120 DPDT 7 HN61KK VA 3A 240 DPST 6 HN61KX010 *See contact arrangement diagrams. 282

10 TOTALINE RELAYS/ACCESSORIES RBM TYPE 91 & 192 RELAYS, HONEYWELL R4222 & R8222 RELAYS SEMI-ENCLOSED 1/4 IN. QUICK CONNECT TERMINALS HN61KL001 HN61KP010,011,012 HN61KP P /4 H x 2-1/8 W x 1-7/8 D RATING (FLA) POWER: INDUCTIVE 120 V 240 V 277 V PILOT: INDUCTIVE /250 V 277 V COIL VOLTS 208/ ARRANGEMENT SPST (pilot) SPDT (power) SPDT (power) SPDT (pilot) SPDT N.C. (power) N.O.(pilot) SPDT (power) SPDT (pilot) SPDT (power) SPDT (pilot) SPDT (power) SPST (pilot) HN61KP003 HN61KP011 HN61KJ006 HN61KP012 HN61KP010 HN61KP004 NOTE: SPDT has power rated normally open contact and pilot duty normally closed contact. *Power Contacts: Inductive, 120V/250 V Resistive, 120V/277 V RBM TYPE 91 RELAYS SPECIAL QUIET OPERATING POWER RELAY FOR ELECTRIC HEAT APPLICATIONS IMPORTANT THE HN61DC024 (DPST) RELAY IS DESIGNED TO OPERATE ONLY ONE INDUCTIVE LOAD. THE INDUCTIVE RATINGS AND THE COMBINED INDUCTIVE AND RATINGS IN THE CHART MAY BE APPLIED TO ONLY ONE OF EITHER POLE OF THIS RELAY. 24 V, 6.2 VA HOLDING COIL ARRANGEMENT : DPST P254 (5) RATING COMBINED INDUCTIVE AND VOLTAGE INDUCTIVE COMBINED INDUCTIVE ONLY 120,240, *See contact arrangement diagram. ARRANGEMENT* DPST 5 HN61DC

11 TOTALINE RELAYS/ACCESSORIES RBM TYPE 93 RELAYS, POTTER BRUMFIELD TYPE KU93 RELAYS MAY BE USED WITH THE RECEPTACLE PACKAGES LISTED BELOW 3/16 IN. QUICK CONNECT TERMINALS RECEPTACLE PACKAGES (include quick connects) COLOR VOLTAGE Black 24 48DA Red DA Green DA ARRANGEMENT S: FPDT P /16 H x 1-9/16 W x 1-7/16 D SPDT DPDT TPDT (1) SPST (3) (7) (10) (11) POWER DUTY RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 120 V 240 V 120 V 240 V DPDT 7 HN61KK TPDT 10 HN61KL030 5 (NC) 5 (NC) 5 (NC) 5 (NC) 5 (NO) 3 (NO) 3 (NO) 3 (NO) 24 TPDT 10 HN61KL038** TPDT 10 HN61KL TPDT 10 HN61KL032 5 (NC) 5 (NC) 5 (NC) 5 (NC) 5 (NO) 3 (NO) 3 (NO) 3 (NO) 240 TPDT 10 HN61KL041** NC = NORMALLY CLOSED S NO = NORMALLY OPEN S *See contact arrangement diagram. **Removable mounting bracket attached. PILOT DUTY RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 125/250 V 250 V 125 VA 125/250 V 24 SPST 1 HN61KA VA 3A 208/230 TPDT 10 HN61KL VA 3A 24 TPDT 10 HN61KL VA 3A 24 TPDT 10 HN61KL VA 3A 120 TPDT 10 HN61KL VA 3A 120 TPDT 10 HN61KL VA 3A 240 TPDT 10 HN61KL VA 5A/3A 24 TPDT 10 HN61KL VA 5A/3A 120 TPDT 10 HN61KL VA 5A/3A 24 SPDT 3 HN61KP023 *See contact arrangement diagrams. Mounting bracket, not removable. Has neon indicator light. Gold diffused contacts. 284

12 TOTALINE RELAYS/ACCESSORIES POTTER BRUMFIELD TYPE PRD RELAYS HEAVY DUTY POWER RELAY SCREW TERMINAL - HN61PB030 1/4 IN. Q.C. - HN61PK W x 2.2 D x 2.3 H - HN61PB W x 3.4 D x 2.5 H - HN61PK ARRANGEMENT S: DPDT SPST (2) P256 (7) RATING (FLA) HOLDING COIL INDUCTIVE VOLTS POWER ARRANGEMENT* 600 V VA SPST 2 HN61PB /277 V 277 V VA DPDT 7 HN61PK240 *See contact arrangement diagrams. RBM TYPE RELAYS DOUBLE BREAK TOTALLY ENCLOSED 1/4 IN. QUICK CONNECT TERMINALS, EXCEPT HN61KR901, 911, 913 SUPPLIED WITH QUICK CONNECT TERMINAL KIT ARRANGEMENT S: P /4 H x 2-1/4 W x 2-7/16 D (1) SPST (4) DPST POWER DUTY RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 120 V 240 V 120 V 240 V DPST 4 HN61KR DPST 4 HN61KJ DPST 4 HN61KR DPST 4 HN61KJ005 *See contact arrangement diagrams. PILOT DUTY RATING INDUCTIVE 125/250 V: 125 VA COIL VOLTS ARRANGEMENT* 24 DPST 4 HN61KR-901 *See contact arrangement diagrams. 285

13 TOTALINE RELAYS/ACCESSORIES POWER DUTY RELAYS * SELF-CONTAINED TO FACILITATE REMOTE MOUNTING * LEAD WIRES ARE COLOR CODED * READY FOR DIRECT MOUNTING TO ANY 1/2 STANDARD ELECTRICAL KNOCKOUT ARRANGEMENT S: SPDT P258 (1) SPST (3) RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 120 V 240 V 120 V 240 V SPST 1 HN61KS SPDT 3 HN61KJ SPST 1 HN61KB SPDT 3 HN61KJ SPDT 3 HN61KJ330 *See contact arrangement diagrams. RELAYS WITH ENCLOSURE * PANEL MOUNTED POWER DUTY RELAY * NEMA TYPE I ENCLOSURE * SCREW TERMINALS * MAY BE MOUNTED IN ANY POSITION EXCEPT RELAY TERMINALS FACING DOWN ARRANGEMENT : DPST (4) P /4 H x 3-1/2 W x 3-1/4 D RATING (FLA) COIL INDUCTIVE VOLTS ARRANGEMENT* 0-600V 0-600V DPST 4 HN61AJ DPST 4 HN61AJ108 *See contact arrangement diagram. * EMERGENCY HEAT PILOT DUTY RELAY * RELAYS - ONE TPST RELAY N.O. ONE DPST RELAY, 1 POLE N.O., 1 POLE N.C. * SUITABLE FOR INDOOR APPLICATION * SCREW TERMINALS * INDUCTIVE RATING: 24 V; /240 V * HOLDING COIL: 24 V, 6 VA : HN65DZ026 P /4 H x 4-1/4 W x 3.0 D 286

14 TOTALINE RELAYS/ACCESSORIES TOTALINE FAN CONTROL CENTER RELAYS 40 VA TRANSFORMER 24 VOLT SECONDARY FITS STANDARD 4 IN. JUNCTION BOX SELF-CONTAINED UNIT REQUIRED NO ADDITIONAL ENCLOSURE UNIT IMPRINTED WITH WIRING RATING: 277 V INDUCTIVE RATING: 3/4 H.P., 120 V; 3/4 H.P., 240 V RELAY COIL VOLTS: 24 P261 ARRANGEMENT S: DPDT SPDT SPST (1) (3) (7) TRANSFORMER PLUG-IN ARRANGEMENT* PRIMARY RELAY DPDT 7 120/208/240 Semi-Enclosed P SPNO/SPNC Semi-Enclosed P SPDT Semi-Enclosed P SPST Semi-Enclosed P SPDT Semi-Enclosed P SPDT Semi-Enclosed P *See contact arrangement diagrams. 287

15 ORS TOTALINE ORS P273 P274A P275 P276A Design Construction: 50/60 Hz Covers: Standard on 40 amp and larger. Meets specifications for devices up to 600 VAC in accordance with Mounting: U/L bulletin no. 508 "Industrial Control Equipment' Panel mount and straight thru wiring. Coil Insulation: Application: Standard Class B insulation. Designed for use in residential and commercial refrigeration, air conditioning, and heating applications. Terminals: Power #10-32 combination hex washer head screw, #10-32 combination hex head with pressure plate or box lug for 4-14 CU/AL wire. Also: 'Water pump motors Blower or fans Compressor motors Quick Connects - (2) male push-ons available on each pole. Coil - (2) male push-ons. Resistance heating and other similar applications. UL / CSA recognized POLE AMPS TERMINAL TYPE COIL VAC AUX LENGTH HEIGHT in. (cm) in. (cm) SINGLE POLE 30 (SCREW TERM. & SHUNT) (8.38) 2.3 (5.84) P SINGLE POLE 30 (SCREW TERM. & SHUNT) (8.38) 2.3 (5.84) P SINGLE POLE 30 (SCREW TERM. & SHUNT) 208/ (8.38) 2.3 (5.84) P TWO POLE 30 (SCREW TERMINALS) (8.38) 2.5 (6.35) P TWO POLE 30 (SCREW TERMINALS) (8.38) 2.5 (6.35) P TWO POLE 30 (SCREW TERMINALS) 208/ (8.38) 2.5 (6.35) P TWO POLE 40 (LUG TERMINALS) (8.38) 2.6 (6.60) P TWO POLE 40 (LUG TERMINALS) (8.38) 2.6 (6.60) P TWO POLE 40 (LUG TERMINALS) 208/ (8.38) 2.6 (6.60)- P THREE POLE 30 (SCREW TERMINALS) 24 P282-X (8.64) 2.6 (6.60) P THREE POLE 30 (SCREW TERMINALS) 24 P282-X (8.64) 2.6 (6.60) P A THREE POLE 30 (SCREW TERMINALS) 120 P282-X (8.64) 2.6 (6.60) P THREE POLE 30 (SCREW TERMINALS) 120 P282-X (8.64) 2.6 (6.60) P A THREE POLE 30 (SCREW TERMINALS) 208/240 P282-X (8.64) 2.6 (6.60) P THREE POLE 30 (SCREW TERMINALS) 208/240 P282-X (8.64) 2.6 (6.60) P A THREE POLE 40 (LUG TERMINALS) 24 P282-X (8.64) 2.6 (6.60) P THREE POLE 40 (LUG TERMINALS) 24 P282-X (8.64) 2.6 (6.60) P A THREE POLE 40 (LUG TERMINALS) 120 P282-X (8.64) 2.6 (6.60) P THREE POLE 40 (LUG TERMINALS) 120 P282-X (8.64) 2.6 (6.60) P A THREE POLE 40 (LUG TERMINALS) 208/240 P282-X (8.64) 2.6 (6.60) P THREE POLE 40 (LUG TERMINALS) 208/240 P282-X (8.64) 2.6 (6.60) P A THREE POLE 50 (LUG TERMINALS) 24 P282-X (10.67) 3.6 (9.14) P THREE POLE 50 (LUG TERMINALS) 120 P282-X (10.67) 3.6 (9.14) P THREE POLE 50 (LUG TERMINALS) 208/240 P282-X (10.67) 3.6 (9.14) P THREE POLE 60 (LUG TERMINALS) 24 P282-X (10.67) 3.6 (9.14) P THREE POLE 60 (LUG TERMINALS) 120 P282-X (10.67) 3.6 (9.14) P THREE POLE 60 (LUG TERMINALS) 208/240 P282-X (10.67) 3.6 (9.14) P THREE POLE 75 (LUG TERMINALS) 24 P282-X P THREE POLE 75 (LUG TERMINALS) 120 P282-X P THREE POLE 75 (LUG TERMINALS) 208/240 P282-X P THREE POLE 90 (LUG TERMINALS) 24 P282-X P THREE POLE 90 (LUG TERMINALS) 120 P282-X P THREE POLE 90 (LUG TERMINALS) 208/240 P282-X P

16 SINGLE POLE OR ORS STRAIGHT THROUGH, TOP WIRING SCREW POWER TERMINALS 50/60 HZ P265 LINE VOLTS FULL LOAD LOCK ROTOR COIL VOLTAGE A. 125 A. 25 A A. 50 A. 25 A. 24 HN51KB A. 40 A. 25 A A. 150 A. 40 A A. 75 A. 40 A. 24 HN51KC A. 50 A. 40 A. TWO POLE OR STRAIGHT THROUGH, TOP WIRING SCREW POWER TERMINALS 50/60 Hz P266 LINE VOLTS FULL LOAD LOCK ROTOR COIL VOLTAGE A. 150 A. 30 A A. 125 A. 30 A. 460 HN52LB A. 100 A. 20 A A. 150 A. 35 A. 24 HN52KC A. 125 A. 35 A. 120 HN52KC A. 100 A. 35 A. 208/240 HN52KC A A. 24 HN52SA A A. 240 A. 50 A A. 200 A. 50 A. 24 HN52KD A. 160 A. 50 A. THREE POLE OR STRAIGHT THROUGH, TOP WIRING QUICK CONNECT TERMINALS 50/60 HZ P267 LINE VOLTS FULL LOAD LOCK ROTOR COIL VOLTAGE A. 150 A. 30 A A. 125 A. 30 A. 24 HN53JN A. 100 A. 30 A A. 240 A. 50 A A. 200 A. 50 A. 24 HN53CD A. 160 A. 50 A. SCREW TERMINALS 50/60 HZ LINE VOLTS FULL LOAD LOCK ROTOR COIL VOLTAGE A. 240 A. 50 A. 120 HN53AB252* A. 115 A. 25 A HN53AB251* A. 105 A. 25 A. *Has Aux. Contacts (1) N.O., (1) N.C., rated volts. P

17 THREE POLE OR ORS PRESSURE LUG TERMINALS LINE VOLTS FULL LOAD LOCK ROTOR COIL VOLTAGE A. 240 A. 50 A. 24 HN53CD A. 200 A. 50 A. 115 HN53CD A. 160 A. 50 A HN53CD209 SCREW TERMINALS P269 P270 LINE VOLTS FULL LOAD LOCK ROTOR COIL VOLTAGE A. 240 A. 40 A A. 160 A. 40 A. HN53AD431* A. 140 A. 40 A. 24 HN53CD A. 240 A. 50 A. 115 HN53CD A. 200 A. 50 A HN53CD A. 160 A. 50 A HN53CD231** 480 HN53CD A 150 A 35 A HN53CB A 125 A 35 A 115 HN53CB A 100 A 35 A *Has Aux. Contacts (1) N.O., (1) N.C., rated volts. **Has Aux. Contacts (1) N.O., (1) N.C. rated volts. P271 LINE COIL FULL LOAD LOCK ROTOR VOLTS VOLTAGE TERMINALS A. 360 A. 75 A. 115 SCREW HN53HF A. 300 A. 75 A. 115 LUG HN53HF115** A. 240 A. 75 A SCREW HN53HF LUG HN53HF207** A. 450 A. 90 A. 115 SCREW HN53HG A. 375 A. 90 A. 115 SCREW HN53HG121** A. 300 A. 90 A SCREW HN53HG A. 540 A. 90 A. 120 SCREW HN53HH210** A. 450 A. 90 A SCREW HN53HH260** A. 360 A. 90 A A. 720 A A. 600 A A. 480 A. **Has Aux. Contacts (1) N.O., (1) N.C. rated volts LUG LUG HN53HJ115 HN53HJ220 FOUR POLE OR STRAIGHT THROUGH, TOP WIRING 50/60 HZ PRESSURE LUG CONNECTOR - HN LINE VOLTS FULL LOAD LOCK ROTOR COIL VOLTAGE A. 240 A. 50 A A. 200 A. 50 A. 24 HN A. 160 A. 50 A. P

18 TOTALINE CONTROL TRANSFORMERS TRANSFORMERS FOR LOW AND MEDIUM VA REQUIREMENTS USE TO STEP DOWN VOLTAGE FOR CONTROL CIRCUITS LARGE SELECTION OF RATINGS AND MOUNTING P277 P278 P279 FIGURE #A FIGURE #B FIGURE #C FIG. VA RATING PRIMARY VOLTS HZ SECONDARY VOLTS A /60 24 P * A /208/240 50/60 24 P * C /208/240 50/60 27/12/2.5 P * C /208/240 50/60 24 P * C / /60 12/24 P * B /208/240/480 50/60 24 P B /208/240/480 50/60 24 P *Supplied with 9 inch leads. CONTROL TRANSFORMERS P277 P278 FIGURE #A FIGURE #B FIG. VA RATING PRIMARY SECONDARY DIMENSIONS (in.) HZ VOLTS VOLTS LENGTH WIDTH HEIGHT A /16 2 HT01AA140 A / /8 1-7/8 2-5/16 HT01BB116 B /4 1-3/4 2 HT01BB265* 2x HT680004* A HT680005* A /24 2-7/ /8 HT01CN001 A /16 2 HT01BC116 A /230 50/ /16 2-3/8 2-1/4 HT01AX220 B /230/460 50/ /4 2-5/8 HT01BD201* A /60 12/ /16 2-7/16 2-3/16 HT01BB231* A /230 50/ /16 2-9/16 HT01BD117 B /2 2-13/16 HT01CZ460 A / /8 2-19/32 HT01AW230 A /208/230 50/ / HT01AW229 A /230/460 50/ /8 2-9/16 HT01AW234 A / /16 HT01BB118 LAM /4 2-1/2 HT01AZ240** B /230/ /4 2-5/8 HT01BD236* B /230/ /16 3-1/8 3-3/4 HT01BB201* A 5/ / /32 2-1/8 2-1/4 HT01BC232 A 1-208/230/265 50/ /4 1-29/32 2 HT01CN002* *Transformer has leads on primary side. **Transformer has leads on primary and secondary sides. 4x4 Conduit box mount (4 inch x 4 inch). 2x4 Conduit box mount (2 inch x 4 inch). LAM Lamination mount. FOR LOW AND MEDIUM VA REQUIREMENTS USE TO STEP DOWN VOLTAGE FOR CONTROL CIRCUITS LARGE SELECTION OF RATINGS AND MOUNTING 291

19 TRANSFORMERS POWER TRANSFORMERS FOR LOW VA REQUIREMENTS TAKES MINIMUM OF SPACE EASILY MOUNTED AND WIRED P282 VA RATING PRIMARY SECONDARY DIMENSIONS (in.) HZ VOLTS VOLTS LENGTH WIDTH HEIGHT / /16 2-3/4 2-5/16 HT01BC / /26 2-5/8 2-11/16 HT01BD461 USE TO STEP DOWN VOLTAGE FOR CONTROLS LARGE SELECTION OF RATINGS FOR CONTROL BOX MOUNTING P283 VA RATING PRIMARY SECONDARY DIMENSIONS (in.) HZ VOLTS VOLTS LENGTH WIDTH HEIGHT / / /2 HT01BZ / /16 4-3/8 3-3/16 HT01BB /550 50/ /8 3-3/4 3-3/16 HT01BE /460 50/ /4 3-3/4 3-3/16 HT01BZ / / / /8 HT01AH /4 3-3/4 3-3/16 HT01BZ /550 50/ /8 4-1/2 3-7/8 HT01BE /2 3-3/16 4-1/2 HT01BZ / /2 3-13/16 HT01BZ / /8 5-1/4 4-1/2 HT01BE / /2 3-13/16 HT01BZ / / /4 5-1/4 4-5/8 HT01BE /2 3-3/16 6 HT01BZ / / /8 5-1/4 4-5/8 HT01BE

20 TRANSFORMERS POWER TRANSFORMERS EASILY WIRED OPEN FRAME REQUIRES LESS SPACE FOR CONTROL BOX APPLICATIONS P284 VA RATING PRIMARY SECONDARY DIMENSIONS (in.) HZ VOLTS VOLTS LENGTH WIDTH HEIGHT / /8 3-3/16 3-3/16 HT01BE /230/460 50/ / /8 HT01BE /230/460 50/ /8 3-15/16 3-7/8 HT01BE /8 3-15/16 3-7/8 HT01BE /230/460 50/ /2 4-3/4 4 HT01BE / /8 3-15/16 3-7/8 HT01BE /8 3-15/16 3-7/8 HT01BE /230/460 50/ /2 5-1/2 4-5/8 HT01BE / /2 4-3/4 4 HT01BE /230/460 50/ /2 5-1/2 4-5/8 HT01BE /230/460 50/ /4 5-1/2 4-5/8 HT01BE / /4 5-1/2 4-5/8 HT01BE228 POWER TRANSFORMERS P285 ENCLOSED WIRING EASILY MOUNTED ON PANEL OR EQUIPMENT 4 KNOCKOUTS FOR CONDUIT CONNECTION VA RATING PRIMARY SECONDARY DIMENSIONS (in.) HZ VOLTS VOLTS LENGTH WIDTH HEIGHT / / /4 3-1/8 2-7/8 HT01AH / / /8 5-1/8 3-1/4 HT01AH /480 50/60 120/ /4 4-13/32 4-3/32 HT01AC / / /8 7-7/8 5-1/2 HT01AH / /16 4-7/8 4-5/8 HT01AH / / /8 5-5/8 5-1/4 HT01AH / /8 5-5/8 5-1/4 HT01AH / / /2 5-5/8 5-1/4 HT01AH / / /8 5-5/8 5-1/4 HT01AH / /8 5-5/8 5-1/4 HT01AH / / /4 7-27/32 7-5/16 HT01AH / /8 9-3/8 6-3/4 HT01AH

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT) 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Table of Contents. HCC Contactor Nomenclature

Table of Contents. HCC Contactor Nomenclature Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose

More information

JARD by MARS JARD by MARS

JARD by MARS JARD by MARS Table of Contents Description Page No. Capacitors Motor Run....................................................................................... J-3 J-5 Motor Start...........................................................................................J-6

More information

30C30 definite purpose contactor

30C30 definite purpose contactor 30C 30FLA Definite Purpose Contactor Robust 1-4 Pole Contactor Arc Covers as standard Industry Standard Mounting RoHS Compliant UL File No: E61703 Contact Data Table 1 Arrangements: 1 Form X (SPST-NO-DM)

More information

XMC0 Series. Definite Purpose Contactors

XMC0 Series. Definite Purpose Contactors Description American Zettler XMC0 series of are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are found in refrigeration, air

More information

XMC0 Series DEFINITE PURPOSE CONTACTORS

XMC0 Series DEFINITE PURPOSE CONTACTORS DESCRIPTION American Zettlers XMC0 series of Definite Purpose Contactors are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are

More information

PULLOUT DISCONNECT SWITCHES

PULLOUT DISCONNECT SWITCHES PULLOUT DISCONNECT SWITCHES Includes multiple knockouts on all enclosure sides Rainproof NEMA 3R outdoor enclosure Pullout Disconnect Switches Fused (Top Open) ENCLOSURE MATERIAL DOOR STYLE VOLTAGE (V)

More information

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance. XMC0 Series Definite Purpose Contactors Description Hongfa s Definite Purpose Contactor XMC0 meets the rigorous demands of the HVAC, refrigeration, heating, data processing, welding, elevators, hoist &

More information

Magnetic Overload Relays

Magnetic Overload Relays Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A Main Feature 1. 1 Pole to 4-Poles versions available with switching current at 15A (1 Pole) and 10A (2-4 Poles). 2. Printed Circuit Board Terminal, Plug-in Terminal and Flanged Case are designed for easy

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM FEATURES Plug-in relay Quick connect receptacles or direct soldering. PCB terminals are also acceptable. Large capacity 30A contact rating. Optional blowout magnet: high dc switching. Wide spacing between

More information

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement. DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally

More information

Series R19. Power Rocker Switches MARK OPTIONS COLOR OPTIONS TERMINATION OPTIONS HOW TO ORDER

Series R19. Power Rocker Switches MARK OPTIONS COLOR OPTIONS TERMINATION OPTIONS HOW TO ORDER CONTACT RATING: 6A 250VAC 10A 125VAC. ELECTRICAL LIFE: 10,000 Operations. MECHANICAL LIFE: 50,000 Operations. CONTACT RESISTANCE: 1,000M-ohms. DIELECTRIC STRENGTHS: >1,500

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012 SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

Part # Features & Applications Specifications Cross Reference

Part # Features & Applications Specifications Cross Reference Solid State Controls 24-ICM450 24-ICM400 Fully Programmable - with LCD diagnostic display. Easy to configure - simple 7-step push-button setup. Easy to customize - set points, variables and features are

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

AC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel:

AC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel: Specification MIL-C-2212 Application Motor control, heater and tungsten lamp switching. Type Select standard type (IC5181C) or quiet type (IC5181D) when control is to meet standard MIL-C-740. All quiet

More information

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES TO 1 (4) A 50 V AC PRODUCT FEATURES 100 million times proven switching principle High, fl exible design variety Excellent actuating characteristic Illuminated and non-illuminated variants ON REQUEST Other

More information

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC) SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.

More information

TOTALINE PROTECTION CONTROLS

TOTALINE PROTECTION CONTROLS TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients

More information

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES TABLE OF CONTENTS Motor Information Guide Definitions And Abbreviations... page 2 Motor Identification Without A Nameplate What To Look For... page 3 Direct Drive Blower Motors: Two Speed... page 4 Three

More information

DEFROST CONTROLS PARAGON ERC-2 ELECTRONIC REFRIGERATION CONTROL

DEFROST CONTROLS PARAGON ERC-2 ELECTRONIC REFRIGERATION CONTROL DEFROST CONTROLS PARAGON ERC-2 ELECTRONIC REFRIGERATION CONTROL Real time clock for defrost control Integrated Control - Temperature Control Function - Defrost Control Function Output Relays [4] - Compressor

More information

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems AC Leak Freeze AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems Will continue to seal additional Leaks for up to 1 year that meet testing specifications Does not contain

More information

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps 5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps The 5 series is a 2 coil mechanical latch electrical reset power relay. It is panel mounted with screw terminals, and has 600 volt spacing. The 5 series

More information

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes) AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification

More information

Function Relays, Interfaces and Converters

Function Relays, Interfaces and Converters Function Relays, Interfaces and Converters Interface Relays Narrow Design 3TX70 interface relays 3TX701 Interface relay, plug-in Plug-in socket interface, complete with relay Contact Rated control Width

More information

Cross reference. Definite Purpose Contactors

Cross reference. Definite Purpose Contactors Cross reference Definite Purpose Contactors HOMER Tyco/PU Siemens/Furnas GE Culterhammer Schneider/Square D. Honeywell XMC0 100 42/45 CR45 C25 8910 R82 XMCK 100 45 CR45 C25 8910 R82 Contactors HOMER Schneider/TE

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

XMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information

XMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1 pole, 1pole+shunt, pole, pole(optional Auxiliary Contact Blocks or Microswitch Blocks

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

SOLDER SHORT SOLDER SCREW

SOLDER SHORT SOLDER SCREW 32 Honeywell MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945. CUT-A-WAY V3 MINIATURE BASIC SWITCH GENERAL INFORMATION V3 miniature basic switches feature high electrical capacity

More information

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910 s DP, DPA, and SYD Class 89 Compact Design Industry Standard Mounting Double Brea Contacts Low Coil VA Straight-Through Wiring Low Cost Definite purpose contactors are ideal for heating, air conditioning,

More information

60T Series Snap-Action Temperature Controls

60T Series Snap-Action Temperature Controls Series SnapAction Temperature Controls SnapAction Temperature Control The line of 3/4 (19mm) bimetal disc temperature controls from ThermODisc offers proven reliability in a versatile, costeffective design.

More information

ches UL File No. E101598

ches UL File No. E101598 Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the

More information

Data Sheet Definite Purpose Contactors Ex9CK Series

Data Sheet Definite Purpose Contactors Ex9CK Series Data Sheet Definite Purpose Contactors Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability.

More information

MERCURY CONTACTORS & RELAYS

MERCURY CONTACTORS & RELAYS MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND

More information

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR: SERIES 782XBX/XDX DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FEATURES FLAG INDICATOR: L.E.D. STATUS LAMP: PUSH BUTTON: LOCK-DOWN DOOR: FINGER-GRIP COVER: I.D. TAG/WRITE LABEL: COVER ADAPTERS: BENEFITS

More information

Furnace and A/C Parts

Furnace and A/C Parts Blower Wheels S1-02619654014 * BLOWER WHEEL (11X10 - CCW - 1/2 BORE) C16 C16 C16 C16 $97.40 S1-02619654709 * BLOWER WHEEL (11X8 - CCW - 1/2 BORE) B12 B12 A12, B12 A12, B12 $95.16 Capacitors Run Oval SKU

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

37T Series Moisture Resistant Temperature Controls

37T Series Moisture Resistant Temperature Controls 37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a

More information

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series Industrial Automation Catalog Section - U906 Relays Selection Guides General Purpose Relays RU Series RR Series For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm Power Relays RL Series PRODUCT DESCRIPTION Quick Connect Flange Mount SPECIFICATIONS Number of poles pole 2 poles Contact Configuration X (SPST, double make) 2X (DPST, double make) Contact material Ag

More information

Model Number Structure

Model Number Structure Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive

More information

GE Industrial Systems. General Purpose Plug-in Relays. Catalog

GE Industrial Systems. General Purpose Plug-in Relays. Catalog GE Industrial Systems General Purpose Plug-in Relays Catalog GE General Purpose Plug-in Relays GE Industrial Systems new CR20 series comprises a comprehensive general purpose plug-in relay family. Often

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

HOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1

HOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1 MERCURY TO METAL CONTACTORS AND RELAYS GLASS SEAL GUIDE RETAINER TEFLON GUIDE MAGNETIC SLEEVE BOBBIN TERMINAL WELD RING CERAMIC INSULATOR ELECTRODE METAL CAP DESCRIPTION MERCURY TO METAL CONTACTOR: The

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION 505 z 509 FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION The movable contacts are carried in stainless steel cages which in turn are mounted in cavities in the molded portion of the cross bar. This

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact

More information

Interactive Catalog Replaces Catalog Pages

Interactive Catalog Replaces Catalog Pages Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls UNIT OBJECTIVES After studying this unit, the reader should be able to Describe and identify power- and non-power-consuming Describe

More information

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control . 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................

More information

1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information

1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information 1980 Rotating Cam Limit Switches Ordering Guide & Technical Information Features Precision Cam adjustment at any angular position of the Camshaft Speeds from 0 to 500 RPM in either direction No special

More information

60T Series Snap-Action Temperature Controls

60T Series Snap-Action Temperature Controls 60T Series Snap-Action Temperature Controls Snap-Action Temperature Control The 60T line of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a versatile, cost-effective

More information

JOSLYN CLARK VACUUM CONTACTORS

JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum

More information

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact. Relays & Wiring 101 Basically, a relay is an electrically operated, remotely controlled switch. A simple electromagnetic relay is an adaptation of an electromagnet. It consists of a coil of wire surrounding

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Instruction Sheet for Powertite Plug, Connector and Receptacle

Instruction Sheet for Powertite Plug, Connector and Receptacle 330087 Instruction Sheet for Powertite Plug, Connector and Receptacle Powertite 200 Amp Pin & Sleeve Receptacles, Cable Connectors and Plugs: NEMA 4X. 600 Volt AC, 250 Volt DC. Wire Recess Diameter:.687.

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai

More information

Basics of Control Components

Basics of Control Components Basics of Control Components Table of Contents Introduction...2 Electrical Symbols...6 Line Diagrams...16 Overload Protection...22 Overload Relays...26 Manual Control...35 Magnetic Contactors and Starters...41

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Series Gemco. Rotating Cam Limit Switches. Micro-Adjust Cams. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH

Series Gemco. Rotating Cam Limit Switches. Micro-Adjust Cams. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH Series 1980 Gemco Rotating Cam Limit Switches Micro-Adjust Cams Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com FEATURING PRECISION

More information

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp 48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp E13224 The 48 series is a contactor with a 4 normally open, double make contacts rated up to 3HP. It uses a solenoid type moving core design

More information

Pressure Control Type KPU

Pressure Control Type KPU MAKING MODERN LIVING POSSIBLE Data sheet Pressure Control Type KPU KPU controls are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

2. No tools required for snap-on accessories require that make modification quick and easy.

2. No tools required for snap-on accessories require that make modification quick and easy. XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1-Pole, 1-Pole+1Shunt, 1-Pole+1NC, 1-Pole+1NO, 2-Pole, 3-Pole,3-Pole+1NC and 3-Pole+1NO,from

More information

Non-illuminated Push Buttons

Non-illuminated Push Buttons Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

JOSLYN CLARK VACUUM CONTACTOR FEATURES

JOSLYN CLARK VACUUM CONTACTOR FEATURES USAVAC COPACT INTERNATIONAL AC VACUU CONTACTOR International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500V Joslyn Clark s unique Compact AC Vacuum Contactors & Starters

More information

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data Table of Contents 1370 DC Loop Contactors....................................3 Catalog Number Explanation...............................3

More information

24HR 30A SPST TM SW. Features. Long Description

24HR 30A SPST TM SW. Features. Long Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ET05C 24HR 30A SPST TM SW Intermatic Inc. Catalog Number Manufacturer Description Weight per unit Product Category ET05C

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials in contact with medium... 3 Technical data... 4 Ordering...

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940 Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits. HA Hinged Armature Auxiliary Hinged armature auxiliary relay to perform auxiliary functions in and circuits. eatures and Benefits Molded case with 4 mounting options Drawout case available Applications

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information