Overview for USPS.xls

Size: px
Start display at page:

Download "Overview for USPS.xls"

Transcription

1

2

3 Overview for USPS.xls Item AUP-X-300B-V3H AUP-X-300B-V3H12V AUP-X-350-V4 AUP-X-350-V5 AUP-X-400-V4 AUP-X-400-V5 Capacity 300W 300W 350W 350W 400W 400W Input Voltage 115/230VAC Auto Voltage 115/230VAC Auto Voltage Input Frequency 60/50Hz 60/50Hz 60/50Hz 60/50Hz 60/50Hz 60/50Hz Input Power Factor >0.6 >0.6 >0.70 >0.70 >0.70 >0.70 Power Factor Correction 0.97 (Active PFC) 0.97 (Active PFC) 0.97 (Active PFC) 0.97 (Active PFC) Rate Surge Protection Yes Yes Yes Yes Yes Yes Output AC Voltage Yes Yes Yes Output DC Current +12V / 15A +12V / 15A + 12 V1 / 14 A + 12 V1 / 14 A + 12 V1 / 15 A + 12 V1 / 15 A +12 V2 / 13A +12 V2 / 13A +12 V2 / 14A +12 V2 / 14A + 5 V / 30 A + 5 V / 30 A + 5 V / 32 A + 5 V / 32 A + 5 V / 36 A + 5 V / 36 A V / 28 A V / 28 A V / 30 A V / 30 A V / 32 A V / 32 A -12 V / 1.0A -12 V / 1.0A -12 V / 0.8A -12 V / 0.8A -12 V / 0.8A -12 V / 0.8A -5V / 0.4A -5V / 0.4A +5V Stand By / 0.75A +5V Stand By / 0.75A +5V Stand By / 2.5A +5V Stand By / 2.5A +5V Stand By / 2.5A +5V Stand By / 2.5A Total DC Output Power Max. continuous total DC output shall not exceed 300W 300W 350W 350W 400W 400W Combined DC Output Max. combined output on +5V & +3.3V shall not exceed Power 180W 180W 240W 240W 260W 260W Battery Charger 27.6V/300mA 27.6V/300mA 27.6V/300mA 27.6V/300mA 27.6V/300mA 27.6V/300mA Weight 5 KGs (with BP5E KGs (with BP5C KGs (with BP5E KGs (with BP5E KGs (with BP5L KGs (with BP5L-2425 USPS Main body: Dimension / Weight 2.1KGs 2.1KGs Battery Pack type, BP-5E, 24V/2.5Ah BP-5C, 24V/2.5Ah BP-5E, 24V/2.5Ah BP-5C, 24V/2.5Ah BP-5L, 24V/3.5Ah BP-5L, 24V/3.5Ah Dimension, 219 x 145 x 42 mm 3, 215 x 145 x 42 mm x 145 x 42 mm 3, 215 x 145 x 42 mm x 146 x 39 mm 3, 241 x 146 x 39 mm 3 Weight 2.8KGs 2.6KGs 2.8KGs 2.6KGs 3.6KGs 3.6KGs Battery type (Lead Acid, PL25-12 / 178 x 35 x 61 PL25-12 / 178 x 35 x 61 PL25-12 / 178 x 35 x 61 PL25-12 / 178 x 35 x 61 WP1214 / 140 x 32 x 109 WP1214 / 140 x 32 x 109 (Maintenance free) Design Inrush Current 60A for 230VAC, 30A for 60A for 230VAC, 30A for Over Voltage protection Yes Yes Yes Yes Yes Yes Over Power Protection Yes >105%~135% Yes >105%~135% Yes >105%~135% Yes >105%~135% Yes >105%~135% Yes >105%~135% Over Current Protection 240VA of each DC output 240VA of each DC output 240VA of each DC output 240VA of each DC output 240VA of each DC output 240VA of each DC output Form Factor Intel ATX V2.03 Intel ATX V2.03 Intel ATX V2.03 Intel ATX V2.03 Intel ATX V2.03 Intel ATX V2.03 ATX12V Version 1.3 ATX12V Version 1.3 ATX12V Version 1.3 ATX12V Version 1.3 ATX12V Version 1.3 ATX12V Version 1.3 Tabelle1 Alpha Plus Electronic Co., Ltd. 1

4 Overview for USPS.xls Item AUP-X-300B-V3H AUP-X-300B-V3H12V AUP-X-350-V4 AUP-X-350-V5 AUP-X-400-V4 AUP-X-400-V5 UPS Mode / Function Specification Capacity 500VA 500VA (Including AC Output 100W) 500VA 500VA (Including AC Output 100W) 600VA 600VA (Including AC Output 100W) AC Output Voltage (To monitor) 230VAC / 0.75A, or 115VAC / 1.5A, 55 +/- 2Hz 230VAC / 0.75A, or 115VAC / 1.5A, 55 +/- 2Hz 230VAC / 0.75A, or 115VAC / 1.5A, 55 +/- 2Hz AC Output Waveform Step Wave Step Wave Step Wave AC Input Voltage Transfer Point ( Undervolt ) From backup to normal : 90 From backup to normal : From backup to normal : 90 From backup to normal : 90 From backup to normal : 90 From backup to normal : AC Input Voltage Protection by FUSE Protection by FUSE Protection by FUSE Protection by FUSE Protection by FUSE Protection by FUSE Transfer Point (Overvolt ) Transfer time 16ms for AC output ( monitor) 16ms for AC output ( monitor) 16ms for AC output ( monitor) System backup time At least 2 minutes At least 2 minutes At least 2 minutes At least 2 minutes At least 2 minutes At least 2 minutes ( Backup for a PC longer backup time can use longer backup time can use longer backup time can use longer backup time can use longer backup time can use longer backup time can use system ) other battery pack other battery pack other battery pack other battery pack other battery pack other battery pack Recharge time 5~8 hours 5~8 hours 5~8 hours 5~8 hours 8~10 hours 8~10 hours Battery Voltage LED display, Buzzer LED display, Buzzer LED display, Buzzer LED display, Buzzer LED display, Buzzer LED display, Buzzer monitoring Communicate Port Dry Contact for RS-232 Dry Contact for RS-232 Dry Contact for RS-232 Dry Contact for RS-232 Dry Contact for RS-232 Dry Contact for RS-232 Windows RUPS 2000 RUPS 2000 RUPS 2000 RUPS 2000 RUPS 2000 RUPS 2000 Linux DOS Novell UNIX RUPS for UNIX RUPS for UNIX RUPS for UNIX RUPS for UNIX RUPS for UNIX RUPS for UNIX Tabelle1 Alpha Plus Electronic Co., Ltd. 2

5 Micro AC-DC UPS (3-IN-1 Designed) for ISDN Router, ID Carmer, CCTV Security Devices. Feature : 1. Wide AC input range from 90 to 300VAC. Suitable for AC unstable area. 2. DC mode transfer designed from AC failed to battery backup mode, to have better efficiency by DC-DC and get longer backup time. 3. Max. 50W total output, 36W output for device and the output range can be from 5~50VDC setup by manufacture before delivery. Most of output voltages are 48V, 24V, 12V, 9V, 7.5V and 5V. And, individual charger circuit designed, max. 14W output can charging the battery max. 1A. It can make sure battery to recharge in the shortest time. 4. Reversed polarity protection, to avoid the end user connected wrong battery polarity to damaged Micro AC-DC UPS and device. chiu0412@seed.net.tw

6 5. Micro AC-DC UPS support DC start function, no need AC Line, just connect the 12V Lead Acid battery or DC Power source, it can support regulated 12V3A output. 6. The end user can choice the battery capacity by backup time. Micro AC-DC UPS can work with most of popular 12VDC Lead Acid Maintenance free battery cell and other type battery are option. The capacity from 1.2Ah to 20Ah are supported. The individual charger circuit design can support Max. 1A charging current. So, the suggest list for largest battery cell is 20Ah. The Lead Acid battery cell is the most popular battery in the world, therefore, if end user need to replace a new battery, they can easily to find in the local marketing. The importer can import Micro AC-DC UPS without battery, to save freight cost. Our design the battery cell is external connection, the benifits are 1. Save the freight cost for importer, because only need to import the Micro AC-DC UPS Main Body. And, you don t need to buy AC/DC Adapter. 2. Importer can use the most of popular lead acid maintenance free battery from local vendor to backup power. 3. And, the wide range battery cell from 12V/1.2Ah to 12V/20Ah supported for different backup time. 4. The after service for battery also can find the local supplier. And, easy to maintenacne by end user. chiu0412@seed.net.tw

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350 POWER SUPPLY MODEL eups-350 SPECIFICATION PAGE: 1 OF 10 Uninterruptible (ATX) Switching Power Supply MODEL eups-350 POWER SUPPLY MODEL eups-350 SPECIFICATION PAGE: 2 OF 10 TABLE OF CONTENTS 1. INTRODUCTION:...

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection

More information

Solar Inverter Manual

Solar Inverter Manual Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency AVR Protection Compact

More information

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI Steca Elektronik INVERTER / CHARGER WITH MPPT: 5000-48 Inverter / Charger with MPPT charge controller All-in-one: 5 kw / 5 kva pure sine wave inverter (10 kw / 10 kva up to 5 s) 80 A MPPT charge controller

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

MERU Solar Off-Grid Inverters

MERU Solar Off-Grid Inverters 1 kva / 2 kva Off-Grid Solar Inverters with LCD and LED displays 24 / 48 VDC battery versions for 1 kva and 48 VDC for 2 kva Pure sine wave with highest efficiency Fully configurable (PV / Grid priority

More information

Steca Elektronik SOLARIX PLI

Steca Elektronik SOLARIX PLI Steca Elektronik Inverter / Charger with MPPT charge controller All-in-one: 5 kw pure sine wave inverter (10 kw up to 5 s) 80 A MPPT charge controller (max. 145 Voc) 60 A charger from AC source (grid or

More information

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...

More information

K50. Technical Sheet

K50. Technical Sheet K50 Technical Sheet 2 Inverter + Charge Controller + K50 1 Photovoltaic Modules Stand Alone Technical Sheet Electric Diagram 3 Technical Characteristics Contacts Battery Pack K50: Electric Diagram Inverter

More information

K10. Technical Sheet

K10. Technical Sheet K10 Technical Sheet 2 Inverter + Charge Controller K10 1 Photovoltaic Modules Stand Alone Technical Sheet Electric Diagram 3 Technical Characteristics Contacts Battery Pack K10: Electric Diagram Inverter

More information

Solar Inverter 3kW-8kW Inverter (off-grid)

Solar Inverter 3kW-8kW Inverter (off-grid) Solar Inverter 3kW-8kW Inverter (off-grid) Max. DC Power Data: 5.67kW-11.52kW Max. DC Voltage: 200V-400V Max. AC Power: 3kW-8kW Output AC Voltage: 220V (Range: 209-231V) Frequency: 50, 60Hz (49.5-60.6Hz)

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9 USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.

More information

PB -300 / 360 Instruction Manual

PB -300 / 360 Instruction Manual PB -0 / 360 Instruction Manual PB-0,360 Instruction Manual ON/OFF SWITCH 2/115VAC SWITCH 2 INLET 3 POLE IEC320 C14 Battery Connection LED +V -V SVR1 CN5 Vadj VR RC DC (+) DC (-) WARNING : Please make sure

More information

AC/DC Converter MBP250-2A13D13M

AC/DC Converter MBP250-2A13D13M 250W, 165-264VAC Input, Dual output AC/DC battery charging module power supply FEATURES Low stand-by power consumption, Maximum instantaneous power up to 350W With charging function, the 12V output Lead-acid

More information

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and

More information

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller User Manual 4KVA/ 5KVA INVERTER / CHARGER With MPPT Controller CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount FN Series Scalable N+ UPS kva to kva Rackmount Advanced Features: * Parallel Rackmount Units with a Single of up to kva * True N+ Redundancy * ECO Mode: 97% Efficiency * DSP Double-Conversion On-line Sinewave

More information

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger User manual Solar Hybrid 1-5KVA Uninterruptible Power Supply / Charger All rights reserved. The information in this document is subject to change without notice. Thank you for purchasing this series UPS.

More information

EM TECH. EMT Series. Technical Description POWER. With Battery Temp. Compensation and Relay Output. Features: Description:

EM TECH. EMT Series. Technical Description POWER. With Battery Temp. Compensation and Relay Output. Features: Description: Technical Description EMT 40000 Series Features: With Battery Temp. Compensation and Relay Output Constant Charging/Loading Trip Point Charging Temp. Compensated Charge Parallel Operation Temp. Controlled

More information

User Manual of Lead Acid Smart Fast Charger (6 A) for 48V Lead Acid Battery 6Ah- 60Ah (110V Only, Standard Female Tamiya plug)

User Manual of Lead Acid Smart Fast Charger (6 A) for 48V Lead Acid Battery 6Ah- 60Ah (110V Only, Standard Female Tamiya plug) User Manual of Lead Acid Smart Fast Charger (6 A) for 48V Lead Acid Battery 6Ah- 60Ah (110V Only, Standard Female Tamiya plug) AA Portable Power Corp (http://www.batteryspace.com) Address: 860 S, 19 th

More information

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0 User Manual Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER Version: 1.0 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic

More information

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation

More information

User Manual V1.0 MaxiFlex 3000

User Manual V1.0 MaxiFlex 3000 User Manual V1.0 MaxiFlex 3000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2 1-5. Maintenance,

More information

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A TP-BC24-300 AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual Specifications and Features: 210W Total Max. DC power output 8A Max. @24V Charge current 7.5A Max. @28V Net weight, only 4.63 lbs/2.1kg Dimensions

More information

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility OFF-GRID PV IVERTERS EssenSolar & Expert series Solution on Unstable or Remote Area without 1kW-5kW FSP Off-Gird Inverters: EssenSolar & Expert series An ideal Off-Grid inverter for households, FSP Off-Grid

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER User Manual 1KVA-5KVA INVERTER / CHARGER Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product

More information

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER WWW.POWERHIGHWAY.NET CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS...... 1 INTRODUCTION... 2 Features... 2 Basic System

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

Foreword. Manual instruction

Foreword. Manual instruction Manual instruction Foreword Thanks for purchasing our UPS, it is safe and reliable, so few maintenance is required. Read this manual carefully and completely. It includes instructions of safety installation

More information

BRAVER UPS. (Uninterruptible Power System) User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

POWER-HUB 12 VOLT PORTABLE POWER STATION

POWER-HUB 12 VOLT PORTABLE POWER STATION POWER-HUB 12 VOLT PORTABLE POWER STATION P/No. PH125 WARNINGS Risk of explosive gas. Working in the vicinity of a lead-acid battery can be dangerous Batteries might release explosive gases during normal

More information

X400. Technical Sheet

X400. Technical Sheet X400 Technical Sheet 2 Inverter + Charge Controller + X400 1 Photovoltaic Modules Stand Alone Technical Sheet Electric Diagram 3 Technical Characteristics Contacts Battery Pack X400: Electric Diagram 1

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION... CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.

More information

1. Important Safety Warning

1. Important Safety Warning Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation... 1 1-5. Maintenance, service and faults... 2 2. Installation and

More information

SAFETY WARNINGS AND GUIDELINES

SAFETY WARNINGS AND GUIDELINES SAFETY WARNINGS AND GUIDELINES Place the inverter in a well-ventilated environment. Ensure that the cooling fan is not blocked and that it operates as intended. Do not use the inverter if the fan fails

More information

User Manual. 6K/10K Online UPS with Isolation Transformer

User Manual. 6K/10K Online UPS with Isolation Transformer User Manual 6K/10K Online UPS with Isolation Transformer Uninterruptible Power Supply System Version: 1.2 Please comply with all warnings and operating instructions in this manual strictly. Save this manual

More information

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K User M anual Rack/Tower Online UPS 1K/1.5K/2K/3K Uninterruptible Power Supply System Version: 1.2 Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3.

More information

Solar Hybrid Inverter SP Efecto Series

Solar Hybrid Inverter SP Efecto Series User Manual Solar Hybrid Inverter SP Efecto Series Version 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System USER MANUAL Blazer Vista 1000/1400/2000 Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for model Blazer Vista 1000/1400/2000

More information

Solar inverter AX-series

Solar inverter AX-series Power Supplies Inverters Solar inverter AX-series 1-5kVA Multifunctional inverter NEU / NEW PV inverter PV / Battery Charger with 3-stage charge Battery-backed power supply Sine wave inverter with charging

More information

Solar Hybrid Inverter SP Efecto Series

Solar Hybrid Inverter SP Efecto Series User Manual Solar Hybrid Inverter SP Efecto Series Version 1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent AutoShutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection Compact

More information

D R C- 4 0 s e r i e s

D R C- 4 0 s e r i e s LPS Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 Features Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Battery low protection /

More information

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

MARUSON TECHNOLOGY. Uninterruptible Power Supply. MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: +1-714-870-6888 FAX: +1-714-870-4888

More information

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL U P S Uninterruptible Power System Line-Interactive Network UPS 800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER User Manual 1KVA-5KVA INVERTER / CHARGER Version: 1.7 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

Technical data sheets

Technical data sheets GE Digital Energy Technical data sheets Digital Energy Uninterruptible Power Supply Series UPS 6-10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4 USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE

More information

New & Renewable Energy

New & Renewable Energy Part 2 ED-9710 _ TRAINER NEW ED-9720 _ TRAINER NEW ED-9731 _ 5W WIND GENERATOR KIT NEW ED-9732 _ 300W WIND GENERATOR KIT NEW ED-9740 _ FUEL CELL TRAINER FOR STUDENTS NEW ED-9741 _ FUEL CELL TRAINER FOR

More information

USER MANUAL DN / DN

USER MANUAL DN / DN USER MANUAL DN-170040/ DN-170041 Online UPS Uninterruptible Power Supply System Version:1.0 Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation...

More information

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA Important Safety Information Before installing UPS Endure 500VA/750VA/1000VA/2000VA, please read the operating instructions carefully.

More information

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL Important Safety Information Before installing UPS EN-1000/ EN-2000, please read the operating instructions carefully. Special attention

More information

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0 User Manual 3KW/5KW INVERTER / CHARGER Version: 1.0 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1 User Manual 3KVA-5KVA INVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4 User Manual 800W-4000W Hybrid solar inverter Version: 1.4 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from PSDCB161220E v.1.0 PSDCB 13,8V/20A/16x1A/65Ah Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 24.04.2017 GREEN POWER CCTV Features: DC 13,8V/20A

More information

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

USER MANUAL. Power GUARD UPS. Uninterruptible Power System USER MANUAL Power GUARD UPS Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Power GUARD that should be followed during

More information

Mission 1K Single Phase UPS

Mission 1K Single Phase UPS Mission 1K Single Phase UPS 1K-2K 2K-3K INSTRUCTION MANUAL Electrical System for Continuity Contents 1.Safety instruction... 3 1.1 Safety instruction... 3 1.2 Symbols indication... 3 2.Product Introduction...

More information

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3 1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER User Manual Version: 2.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features...

More information

X600. Technical Sheet

X600. Technical Sheet X600 Technical Sheet 2 Inverter + Charge Controller + X600 1 Photovoltaic Modules Stand Alone Technical Sheet Electric Diagram 3 Technical Characteristics Contacts X600: Electric Diagram 1 2 3 Photovoltaic

More information

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1 User Manual 1.5KVA-3KVA INVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121231B OWNERS

More information

USER MANUAL. E4 LCD TX 5000(S) / 6000(S) / (S) With Output Isolation Transformer. Uninterruptible Power Supply System

USER MANUAL. E4 LCD TX 5000(S) / 6000(S) / (S) With Output Isolation Transformer. Uninterruptible Power Supply System USER MANUAL E4 LCD TX 5000(S) / 6000(S) / 10 000(S) With Output Isolation Transformer Uninterruptible Power Supply System Table of Contents 1. IMPORTANT SAFETY INSTRUCTIONS:... 2 1-1. TRANSPORTATION...

More information

Low Frequency Pure Sine Wave Inverter. Operatinal Manual

Low Frequency Pure Sine Wave Inverter. Operatinal Manual Low Frequency Pure Sine Wave Inverter Operatinal Manual Ⅰ.Operating Instruction Content Ⅰ.Operating Instruction---------------------------2 Ⅱ.Outlook drawing of inverter---------------------3 Ⅲ.Description

More information

User Manual 1.5KVA-3KVA INVERTER / CHARGER

User Manual 1.5KVA-3KVA INVERTER / CHARGER User Manual 1.5KVA-3KVA INVERTER / CHARGER Version: 1.0 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

Indicative Battery Testers. Intelligent Battery Tester Chrome Tester OPERATIONS MANUAL. IBT Chrome Tester BT IBTCHR

Indicative Battery Testers. Intelligent Battery Tester Chrome Tester OPERATIONS MANUAL. IBT Chrome Tester BT IBTCHR OPERATIONS MANUAL IBT Chrome Tester BT IBTCHR IMPORTANT! The IBT Chrome is designed to test 12V SLA and Car Batteries from 1.2Ah-200Ah. Damage or injury may result if connected to voltage above 15VDC.

More information

PRODUCT PRESENTATION PROTECT B.PRO DATA&IT, C-UPS

PRODUCT PRESENTATION PROTECT B.PRO DATA&IT, C-UPS PRODUCT PRESENTATION PROTECT B.PRO DATA&IT, C-UPS Office, SoHo, IT segment Compact UPS Home, SoHo Surge protection AEG S COMMERCIAL COMPACT-UPS PRODUCT PORTFOLIO AND FIELD APPLICATION PROTECT BASIC Power

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

SOLARINVERTER MPPT 4KVA - 5KVA

SOLARINVERTER MPPT 4KVA - 5KVA SOLARINVERTER SOLARINVERTER MPPT 4KVA - 5KVA 420-00286-01 Table of Contents ABOUT THIS MANUAL...1 Purpose...1 Scope...1 SAFETY INSTRUCTIONS...1 INTRODUCTION...2 Features...2 Basic System Architecture...2

More information

Pure Sine Wave Inverter. Operational Manual

Pure Sine Wave Inverter. Operational Manual Pure Sine Wave Inverter Operational Manual FAUT O/OFF AC IVERTER ETER Ⅰ.Operating Instruction 1-1. Open-package inspection Content Ⅰ.Operating Instruction---------------------------2 Ⅱ.Outlook drawing

More information

User Manual. PF 1 6K/10K Rack/Tower Online UPS

User Manual. PF 1 6K/10K Rack/Tower Online UPS User Manual PF 1 6K/10K Rack/Tower Online UPS Uninterruptible Power Supply System Version: 1.0 Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The Supreme series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models

More information

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA Appliances 420-00288-01 PC TV Airconditioning Fridge Washing machine Table Of Contents ABOUT THIS MANUAL...1 Purpose... 1 Scope... 1 SAFETY

More information

User Manual. PF1.0 1K/1.5K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.4

User Manual. PF1.0 1K/1.5K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.4 User Manual PF1.0 1K/1.5K/2K/3K Online UPS Uninterruptible Power Supply System Version: 1.4 Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation...

More information

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1 User Manual 1KVA-5KVA INVERTER / CHARGER Version: 2.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL 1 A. INTRODUCTION The AIMS Power pure sine inverter product line is used for back-up power. The pure sine product line is ideal for sensitive

More information

User Manual WT Combi-S Pure Sinus Wave Inverter

User Manual WT Combi-S Pure Sinus Wave Inverter User Manual WT Combi-S Pure Sinus Wave Inverter Contents 1. Important Safety information 1.1. Safety Information part 1 1.2. Safety information part 2 2. General Features 2.1. Product overview 3. Connection

More information

Series 120/120VAC Universal Tower/Rack Mount

Series 120/120VAC Universal Tower/Rack Mount V Series 120/120VAC Universal Tower/Rack Mount Standard 1000VA, 1500VA, 2000VA & 3000VA LB Extended Models 900VA, 1250VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA V Series 120/120VAC Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven

More information

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3 User Manual PF0.9 1K/2K/3K Online UPS Uninterruptible Power Supply System Version: 1.3 Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation...

More information

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A) A Complete solution for small battery-backed dc instrument power systems. DATASHEET Supply 12Vdc 8A or 24Vdc 6A loads Ideal for RTU s, dataloggers, remote field instrumentation, alarm systems, etc. where

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. PB-300 / 360 USER'S MANUAL SPECIFICATION : PB-300 MODEL BOOST CHARGE VOLTAGE

More information

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5 OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER Version 1.5 1 Product Overview EMBC-8025 is an intelligent switching mode battery charger with float maintenance. It is designed to offer maximum

More information

Handbuch USV PTR GRAFENTHAL

Handbuch USV PTR GRAFENTHAL Handbuch GRAFENTHAL USV PTR-10000 GRAFENTHAL GmbH von-monschaw-straße 3 47574 Goch info@grafenthal.de www.grafenthal.de Copyright 2016 GRAFENTHAL GmbH, Alle Rechte vorbehalten. GRAFENTHAL ist eine eingetragene

More information

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

MARUSON TECHNOLOGY. Uninterruptible Power Supply. MARUSON TECHNOLOGY Uninterruptible Power Supply Automatic Regulator Power Distribution Unit Inverter Maruson Technology Corporation 1351 Titan Way, Brea, CA 92821, USA TEL: +1-714-870-6888 FAX: +1-714-870-4888

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

Solar Hybrid Inverter SP Initial Series

Solar Hybrid Inverter SP Initial Series User Manual Solar Hybrid Inverter SP Initial Series Version: 1.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

Solar Power System. User Manual

Solar Power System. User Manual Solar Power System User Manual System introduction The point of the Solar Power System is to replace home power. It is also useful in situations such as: emergencies (rescue and disaster support), no power

More information