1 green power 2.0 and Delphys BC Modbus - TCP / Jbus serial link Installation and operating manual GB

2 Index 1. Foreword 4 2. Safety Requirement Using conditions DELPHYS Green Power Operating Reference 4 3. Environment Recycling of electrical products and equipment 4 4. Introduction General purpose Modbus protocol Data decoding 5 5. Installation Inside UPS Com-Slots localisation Modbus serial interface plug in Modbus interface in parallel system configuration Connections and wiring Modbus Serial link default settings How to change the serial link settings? 8 6. Configuration of the Modbus TCP IDA connection 9 7. Conventions Frame errors management 9 8. Modbus in Single UPS unit How to read data Incoming data structure Ups Identification: Address 0x1100, 32 Words Date & Hours: Address 0x1360, 4 Words Ups Configuration: Address 0x1120, 16 Words Unit Status: Address 0x1143, 4 Words Unit Alarms: Address 0x114A, 4 Words Unit Measurements tables: Address 0x1220, 80 words Unit Enabled Controls Table: Address 0x1150; 1 Words Controls Send To Ups: Address 0x1190, write 1 words 18 2 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

3 9. MODBUS IN modular PARALLEL SYSTEM CONFIGURATION Reminder Modbus table in modular parallel system Ups Identification: Address 0x0100, 32 Words Date & Hours: Address 0x0360, 4 Words Ups Configuration: Address 0xm120, 16 Words Preliminary Remarks Ups Status: Address 0x0140, 3 Words Ups Alarms: Address 0x0148, 2 Words Ups Measurements: Address 0x0200, 32 Words Ups Enabled Controls Table: Address 0xm150, 2 Words To Send Control To Ups: Address 0x15b0, Write 1 Words 24 ENGLISH 10. MODBUS IN PARALLEL SYSTEM with centralised bypass Reminder Modbus table in parallel system with centralised bypass Ups Identification: Address 0x0100, 32 Words Date & Hours: Address 0x0360, 4 Words Ups Configuration: Address 0xm120, 16 Words Preliminary Remarks Ups Status: Address 0x0140, 3 Words Ups Alarms: Address 0x0148, 2 Words Ups Measurements: Address 0x0200, 32 Words Ups Enabled Controls Table: Address 0xm150, 2 Words To Send Control To Ups: Address 0x15b0, Write 1 Words Bypass TABLE Bypass Status: Address 0xF143, 4 Words Bypass Alarms: Address 0xF14A, 4 Words Bypass Measurements tables: Address 0xF220, 80 words Module TABLE Module Status: Address 0xm143, 4 Words Module Alarms: Address 0xm14A, 4 Words Module Measurements tables: Address 0xm220, 80 words 41 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 3

4 1. Foreword We thank you for the trust you have in our Uninterruptible Power Systems. This equipment is fitted with up to date technology. Rectifier and inverter subsets are provided with power semiconductors (IGBT) including a digital micro-controller. Our equipment complies with IEC EN standard. CAUTION : This is a product for restricted sales distribution to informed partners. Installation restrictions or additional measures may be needed to prevent disturbances. SOCOMEC UPS reserves the right to modify their specifications at any time as far as this contributes to technical progress. 2. Safety Requirement Using conditions Do read carefully these operation instructions before using the JBUS/MODBUS interface. Whatever the repairs, they must be made only by authorised staffs, which have been suitably trained. For an optimal operation, it is recommended to maintain the ambient temperature and humidity of the DELPHYS Green Power environment below the values specified by the manufacturer DELPHYS Green Power Operating Reference Respect the safety requirements. Do read carefully the operation instructions of DELPHYS Green Power. This equipment meets the requirements of the European directives applied to this product. As a consequence it is labelled as follows: 3. Environment Recycling of electrical products and equipment Provision is made in European countries to break up and recycle materials making up the system. The various components must be disposed of in accordance with the legal provisions in force in the country where the system is installed. 4 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

5 4. Introduction General purpose This document provides required information of the MODBUS protocol serial link or Ethernet network. Before connecting a supervision equipment or BMS system (Building management system) to the UPS, it is necessary to install and set up the serial interface or network configurations in the case of a network connection Modbus protocol ENGLISH This document does not explain the MODBUS protocol management. Please refer on web site for more information. The DELPHYS Green Power MODBUS uses the following functions : function 3 for reading Input Registers (16 bits), function 6 for writing single Registers (to control DELPHYS Green Power). The data field is composed of 1 word, defined by a MSB (most significant byte) and a LSB (lowest significant byte), and displayed in the following order on the serial link. 1 WORD DATA b7 MSB b0 b7 LSB b0 b15 b Data decoding Status and alarms Information This information are coding in bit. This means that 1 word defines 16 information. If the related bit is set to 1, this information is active or true. Measurements and counters data 1 word defines a measurement or a counter. Some values are numeric decimal signed or unsigned (0 to or from to 32767), or in hexadecimal (0x0000 to 0xFFFF). DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 5

6 5. Installation Inside UPS Com-Slots localisation The «Com-Slots» integrates all communication interfaces and it is located on the right side. 2 1 Please, see on the manual of the concerned UPS to see the correct localisation of the «com slot 2» Modbus serial interface plug in The serial interface should be plugged in the slot 2, and fixed with 2 crews Modbus interface in parallel system configuration There is only one MODBUS serial link interface for a parallel system configuration. One serial interface is used for the whole installation. The access to the data of the UPS module or unit is managed by the table addressing. In a parallel installation with centralized bypass, it is recommended to install the serial card in slot 2 of the bypass. 6 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

7 Installation Inside UPS Connections and wiring NOTE : there is only one connection per interface (RS232 or RS422 or RS485) RS232 connection: Standard PC connection Sub-D 9 pins connector Pin 2 : Rx Pin 3 : Tx Pin 5 : GND RTX + RTX - ENGLISH Isolated RS485 connection 2 wires connection «dip-switch 1» allows connecting the terminal resistor Isolation via opto-coupler 2 polarization resistors could be removed easily (if needed). the shield should be earthing at one point. TX + TX Isolated RS422 connection 4 wires connection «dip-switch 1 and 2» allows connecting the terminal resistor Isolation via opto-coupler 4 polarization resistors could be removed easily (if needed). RX + RX - the shield should be earthing at one point. Before making any connection, please check the cabling. A wrong connection or cabling can damage the serial link interface. DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 7

8 Installation Inside UPS Modbus Serial link default settings Baud rate: 9600 bauds Parity: none Data: 8 bits Stop: 1 bit Slave: 1 The serial link settings can be set from the control panel How to change the serial link settings? Available baud rate: bauds Parity: even - ODD - NONE Slave number: 1 to 32 Please, see on the manual of the concerned UPS to see the correct localisation of the «com slot» 8 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

9 6. Configuration of the Modbus TCP IDA connection This protocol is available via Ethernet. RJ45 on the back of the mimic panel allows the connection to Ethernet network. The IP settings and MODBUS TCP port selection is available on the mimic panel. ENGLISH 7. Conventions The table addresses are written in hexadecimal, beginning with 0x. Some PLC systems request a relative address starting from 400 (0x0190) or (0x9C41), on this address it s necessary to add the first address of the MODBUS table Frame errors management In case of wrong data request, the DELPHYS Green Power answers with the following frame error : Error function code Error code Cause 80 + code function 1 Function error 80 + code function 2 Addresses error 80 + code function 3 Wrong data 80 + code function 6 busy 80 + code function 8 Write register error DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 9

10 8. Modbus in Single UPS unit TABLE Start addresses Table length in words MODBUS FUNCTION UPS Identification 0x READ Date and hours 0x READ UPS Configurations 0x READ UNIT Status (64 bits) 0x READ UNIT Alarm (80 bits) 0x114A 5 3 READ UNIT Measurements 0x READ Controls permission 0x READ UPS Controls 0x WRITE How to read data The identification, status and alarms tables should be read completely (this means the number of word to read is equal to the table length). The measurements table should be read word by word or per group, without exceed the length of the table. (from 0x1220 to 0x127F) Incoming data structure Example of 6 words MSB 0 LSB 0 MSB 1 LSB 1 MSB 2 LSB 2 MSB 3 LSB 3 MSB 4 LSB 4 MSB 5 LSB 5 WORD 0 WORD 1 WORD 2 WORD 3 WORD 4 WORD 5 b15 b0 b15 b0 b15 b0 b15 b0 b15 b0 b15 b0 S015 S000 S031 S016 S047 S032 S063 S048 S079 S064 S095 S080 A015 A000 A031 A016 A047 A032 A063 A048 M000 M001 M002 M003 M004 M DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

11 Single unit ups modbus tables Ups Identification: Address 0x1100, 32 Words Code Description Number Address Type Remarks I000 UPS identification 10 WORDS 0x word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char I010 UPS Description 6 WORDS 0x110A 1 word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char I016 Location 6 WORDS 0x word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char I022 Serial number 10 WORDS 0x word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char Date & Hours: Address 0x1360, 4 Words ENGLISH Code Description Number Address Type Remarks D00 Minutes / seconds 1 WORDS 0x1360 Byte value MSB = minutes, LSB = seconds D01 Hours / day 1 WORDS 0x1361 Byte value MSB = day, LSB = hours D02 Month / day of week 1 WORDS 0x1362 Byte value MSB = month, LSB = day of the week 1=Monday...7=Sunday D03 Year 1 WORDS 0x = Ups Configuration: Address 0x1120, 16 Words Code Measurements Unit Address Remarks T000 Kind of equipment 0x1120 1= single unit, 3= parallel + centralised bypass 6 = modular parallel system T001 UPS output power kva 0x1121 T002 Unit output power kva 0x1122 T003 Unit number 0x T004 Number of Unit 0x T005 UPS redundant 0x T006 With battery 0x T007 With flywheel 0x T008 0x1128 T009 With genset 0x T010 T011 T012 0x112A 0x112B 0x112C T013 With rectifier input supply 0x112D 0-1 T014 Single 0x112E 0 = Tri, 1 = Single T015 Measurements management 0x112F 0 = x 1, 1 = x 10 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 11

12 Single unit UPS Modbus Tables Unit Status: Address 0x1143, 4 Words Code Description Bit Address Remarks S048 Load on inverter 0 0x1143 S049 Load on auto. Bypass 1 S050 Load on maintenance Bypass 2 S051 Load not supplied 3 S052 Unit is available 4 S053 Unit isolated from inst. 5 S054 Output switch Q2/3 closed 6 S055 Rectifier ON 7 S056 Battery charging 8 S057 Battery charged 9 S S059 Inverter ON 11 S060 Inverter switch/contactor closed 12 S061 Bypass switch activated 13 S S063 Servicing alert 15 S064 Rectifier input supply fault 0 0x1144 S065 Bypass input supply out of tolerance 1 S066 Bypass input supply failure V/F 2 2 S067 Bypass input supply is synchro ref 3 S068 Ext. synchro ref (ACS on) 4 S069 Synchro forced on ACS 5 S070 UPS general power off input active 6 S071 Generator set active 7 S072 Unit in normal mode 8 S073 Unit in eco-mode 9 S S075 Unit in stand-by mode 11 S S S S079 Unit in servicing mode DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

13 Single unit UPS Modbus Tables Code Description Bit Address Remarks S080 Unit Start procedure progress 0 0x1145 S081 Unit maintenance bypass procedure progress 1 S082 2 S083 Battery test interrupted 3 S084 Battery test in progress 4 S085 Battery test in stand-by 5 S086 6 S087 7 S088 8 S089 9 S090 Q1 closed 10 S091 Q4 closed 11 S092 Local maintenance bypass Q5 clos. 12 S093 Remote maintenance bypass closed 13 Only on parallel S094 Q21 switch closed 14 Only on parallel S095 Q22 switch closed 15 Only on parallel S096 Auxiliary input 1 active 0 0x1146 S097 Auxiliary input 2 active 1 S098 Auxiliary input 3 active 2 S099 Auxiliary input 4 active 3 S100 Auxiliary input 5 active 4 S101 Auxiliary input 6 active 5 S102 Auxiliary input 7 active 6 S103 Auxiliary input 8 active 7 S104 Auxiliary input 9 active 8 S105 Auxiliary input 10 active 9 S106 Auxiliary input 11 active 10 S107 Auxiliary input 12 active 11 S S S S111 Acknowledgement alarm request 15 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 13

14 Single unit UPS Modbus Tables Unit Alarms: Address 0x114A, 4 Words Code Description Bit Address Remarks A032 Unit Imminent stop 0 0x114A A033 Unit overload 1 A034 Transfer blocked 2 A035 Transfer impossible 3 A036 Insufficient Resources 4 Only on parallel A037 5 A038 6 A039 Rectifier critical 7 A040 Inverter critical 8 A041 Bypass critical 9 A042 Common critical 10 A043 FAN alarm 11 A044 Back feed protection open 12 A045 ACS synchro source fault 13 A A A048 Operating on battery 0 0x114B A049 Battery alarm 1 A050 Battery room 2 A051 Battery discharged 3 A052 End of autonomy time 4 A053 Battery test failure 5 A054 Earth leakage fault 6 A055 Battery circuit open 7 A056 On battery with mains OK 8 A057 DC voltage not OK 9 A058 Rectifier preventive 10 A059 Inverter preventive 11 A060 Bypass preventive 12 A061 Common preventive 13 A062 Mimic panel 14 A063 Ambient T max 15 A064 BHC general alarm 0 0x114C A065 1 A066 2 A067 3 A068 4 A069 5 A DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

15 Single unit UPS Modbus Tables Code Description Bit Address Remarks A071 7 A072 8 A073 9 A A A A A A A080 Preventive maintenance 0 0x114D A081 1 A082 Maintenance bypass alarm 2 A083 Rotation phase fault 3 A084 Rectifier or Bypass Input supply not OK 4 A085 5 A086 6 A087 7 A088 8 A089 9 A A A A A094 Output since xx minutes on auto bypass 14 A095 Unit General alarm 15 A096 Fly Wheel disconnected 0 0x114E A097 Fly Wheel Critical 1 If set A098 Fly Wheel preventive 2 A099 3 A100 4 A101 Aux. input alarm 5 If set A102 6 A103 7 A104 8 A105 9 A A A A109 kw - kva configuration Error 13 A110 Eco-mode configuration Error 14 A111 Option board alarm 15 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 15

16 Single unit UPS Modbus Tables Unit Measurements tables: Address 0x1220, 80 words Code Description Unit Address Format Format T015=0 T015=1 M032 Output voltage U12 V 0x1220 ### ### M033 Output voltage U23 V 1 ### ### M034 Output voltage U31 V 2 ### ### M035 Output voltage L1 V 3 ### ### M036 Output voltage L2 V 4 ### ### M037 Output voltage L3 V 5 ### ### M038 Output current L1 A 6 # ### # ###.# M039 Output current L2 A 7 # ### # ###.# M040 Output current L3 A 8 # ### # ###.# M041 Output frequency x10 Hz 9 ##.# ##.# M042 Output Power factor L1 A +/- #.## +/- #.## M043 Output Power factor L2 B +/- #.## +/- #.## M044 Output Power factor L3 C +/- #.## +/- #.## M045 Output Active Power L1 kw D # ### # ###.# M046 Output Active Power L2 kw E # ### # ###.# M047 Output Active Power L3 kw F # ### # ###.# M048 Output Apparent Power L1 kva 0x1230 # ### # ###.# M049 Output Apparent Power L2 kva 1 # ### # ###.# M050 Output Apparent Power L3 kva 2 # ### # ###.# M051 Output Crest Factor 3 #.# #.# M052 Output load rate L1 % 4 ### ### M053 Output load rate L2 % 5 ### ### M054 Output load rate L3 % 6 ### ### M055 Unit load rate % 7 ### ### M056 Unit Power S Output kva 8 # ### # ###.# M057 Unit Power P Output kw 9 # ### # ###.# M058 Rectifier input supply volt. U12 V A ### ### M059 Rectifier input supply volt. U23 V B ### ### M060 Rectifier input supply volt. U31 V C ### ### M061 Rectifier V1 V D ### ### M062 Rectifier V2 V E ### ### M063 Rectifier V3 V F ### ### M064 Rectifier input supply frequency x10 Hz 0x1240 ##.# ##.# M065 Rectifier input supply current L1 A 1 ###.# ###.# M066 Rectifier input supply current L2 A 2 ###.# ###.# M067 Rectifier input supply current L3 A 3 ###.# ###.# M068 Inverter output voltage U12 V 4 ### ### M069 Inverter output voltage U23 V 5 ### ### M070 Inverter output voltage U31 V 6 ### ### 16 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

17 Single unit UPS Modbus Tables Code Description Unit Address Format Format T015=0 T015=1 M071 Inverter frequency x10 Hz 7 ##.# ##.# M072 Bypass input supply voltage U12 V 8 ### ### M073 Bypass input supply voltage U23 V 9 ### ### M074 Bypass input supply voltage U31 V A ### ### M075 Bypass input supply voltage V1 V B ### ### M076 Bypass input supply voltage V2 V C ### ### M077 Bypass input supply voltage V3 V D ### ### M078 Bypass input supply frequency x10 Hz E ###.# ###.# M079 Ambient T C F ##.# ##.# M080 Vdc + V 0x1250 ### ### M081 M082 Battery voltage string + V 2 ### ###.# M083 M084 Battery current + A 4 # ### # ###.# M085 M086 6 M087 7 M088 8 M089 9 M090 A M091 Battery T C B ##.# ##.# M092 Average battery T C C ##.# ##.# M093 Battery capacity Ah D # ### # ###.# M094 Battery capacity % E ### ### M095 Remaining backup time mn F ### ### M096 0x1260 M097 1 M098 2 M099 3 M100 4 M101 5 M102 6 M103 7 M104 8 M105 9 M106 A M107 B M108 C M109 D M110 E M111 F ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 17

18 Single unit UPS Modbus Tables Unit Enabled Controls Table: Address 0x1150; 1 Words Code Description Bit Address Remarks V007 Eco-mode 7 0x1150 V008 Normal-mode 8 V032 Unit Start procedure 0 0x1152 V033 Reserved 1 V034 Make unit available 2 V035 Switch load to inverter 3 V036 Switch load to mains 4 V037 Switch off unit output 5 V038 6 V039 7 V040 Rectifier on 8 V041 Rectifier off 9 V042 Inverter on 10 V043 Inverter off 11 V V045 Battery test Controls Send To Ups: Address 0x1190, write 1 words For a remote UPS control, it is necessary to set the serial interface in remote mode using ADICOM interface. The control table below shows if the selected control is allowed or not. If the control sent to the UPS is not allowed, the function will be ignored. Controls available by MODBUS connection: Code Description Bit To Write Address Remarks C007 Eco-mode 7 0x1190 C008 Normal-mode 8 C032 Unit Start procedure 0 0x1192 C033 Reserved 1 C034 Make unit available 2 C035 Switch load to inverter 3 C036 Switch load to mains 4 C037 Switch off unit output 5 LOAD OFF IMMEDIATE!! C038 6 C039 7 C040 Rectifier on 8 C041 Rectifier off 9 C042 Inverter on 10 C043 Inverter off 11 C C045 Battery test 13 C C047 C048 Reset alarm 0 0x DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

19 9. MODBUS IN modular PARALLEL SYSTEM CONFIGURATION Reminder In UPS parallel system configuration, there is only one MODBUS interface. The addresses mapping gives the possibility to read data from each unit and system. There is no link between the MODBUS salve number and the unit number. The interface is plugged in the com-slots in the UPS unit 1 com slots in case of modular system (see bellow). ENGLISH MODBUS link setting The setting of the link is made from the mimic panel unit where the board is plugged. How to read data: In the MODBUS table, one part is dedicated to UPS part; it means the data from the whole system. This part is the same for each unit. Same data are present in the UPS fields addresses. UNIT 1 UNIT 2 UNT 3 UPS DATA = UPS DATA = UPS DATA UNIT 1 DATA UNIT 2 DATA UNIT 3 DATA DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 19

20 Modbus tables in modular parallel system configuration Modbus table in modular parallel system Table Start Addresses Table Length In Words Modbus Function UPS Identification 0x READ Date and hours 0x READ UPS Configurations 0x READ UPS Status (48 bits) 0x READ UNIT Status (64 bits) 0xm READ UPS Alarms (32 bits) 0x READ UNIT Alarm (80 bits) 0xm14A 5 3 READ UPS Measurements 0x READ UNIT Measurements 0xm READ Controls permission 0xm READ UPS Controls 0xm WRITE m = number of unit Example: 0x3100 = ID of unit 3 0x3140 = UPS States 0x3143 = unit 3 states Ups Identification: Address 0x0100, 32 Words See unit part Date & Hours: Address 0x0360, 4 Words See unit part Ups Configuration: Address 0xm120, 16 Words See unit part Preliminary Remarks The UNIT data are the same as described for single unit. Following tables describe only the UPS part (common for all units) 20 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

21 Modbus tables in modular parallel system configuration Ups Status: Address 0x0140, 3 Words Code Description Bit Address Remarks S000 Load supplied by inverter 0 0x0140 S001 Load on automatic bypass 1 S002 Load on maintenance. Bypass 2 S003 Load not supplied 3 S004 Eco-mode 4 S005 Energy Saver 5 S006 UPS in normal mode 6 S007 UPS Starting procedure in progress 7 S008 UPS on maintenance bypass proc. in progress 8 S009 9 S S S S S S015 Remote control enabled 15 S016 Unit 1 operating 0 0x0141 S017 Unit 2 operating 1 S018 Unit 3 operating 2 S019 Unit 4 operating 3 S020 Unit 5 operating 4 S021 Unit 6 operating 5 S022 Unit 7 operating 6 S023 Unit 8 operating 7 S024 8 S025 9 S S S S S S S032 Unit 1 available 0 0x0142 S033 Unit 2 available 1 S034 Unit 3 available 2 S035 Unit 4 available 3 S036 Unit 5 available 4 S037 Unit 6 available 5 S038 Unit 7 available 6 S039 Unit 8 available 7 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 21

22 Modbus tables in modular parallel system configuration Ups Alarms: Address 0x0148, 2 Words Code Description Bit Address Remarks A000 UPS imminent stop 0 0x0148 A001 UPS overload 1 A002 UPS transfer blocked 2 A003 UPS transfer impossible 3 A004 UPS insufficient Resource 4 A005 UPS Redundancy loss 5 A006 Parallel fault 6 A007 7 A008 8 A009 9 A A A A A A A016 Unit 1 general 0 0x0149 A017 Unit 2 general 1 A018 Unit 3 general 2 A019 Unit 4 general 3 A020 Unit 5 general 4 A021 Unit 6 general 5 A022 Unit 7 general 6 A023 Unit 8 general 7 A024 8 A025 9 A A A A A A DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

23 Modbus tables in modular parallel system configuration Ups Measurements: Address 0x0200, 32 Words Code Description Unit Address Format Format T015=0 T015=1 M000 Output voltage U12 V 0x0200 ### ### M001 Output voltage U23 V 1 ### ### M002 Output voltage U31 V 2 ### ### M003 Output voltage L1 V 3 ### ### M004 Output voltage L2 V 4 ### ### M005 Output voltage L3 V 5 ### ### M006 Output current L1 A 6 # ### # ###.# M007 Output current L2 A 7 # ### # ###.# M008 Output current L3 A 8 # ### # ###.# M009 Output frequency x10 Hz 9 ##.# ##.# M010 Output Power factor L1 A +/- #.## +/- #.## M011 Output Power factor L2 B +/- #.## +/- #.## M012 Output Power factor L3 C +/- #.## +/- #.## M013 Output Active Power L1 kw D # ### # ###.# M014 Output Active Power L2 kw E # ### # ###.# M015 Output Active Power L3 kw F # ### # ###.# M016 Output Apparent P. L1 kva 0x210 # ### # ###.# M017 Output Apparent P. L2 kva 1 # ### # ###.# M018 Output Apparent P. L3 kva 2 # ### # ###.# M019 Output Crest Factor 3 #.# #.# M020 Output load rate L1 % 4 ### ### M021 Output load rate L2 % 5 ### ### M022 Output load rate L3 % 6 ### ### M023 UPS load rate % 7 ### ### M024 UPS Output power kva 8 # ### # ###.# M025 9 M026 A M027 B M028 C M029 D M030 E M031 F ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 23

24 Modbus tables in modular parallel system configuration Ups Enabled Controls Table: Address 0xm150, 2 Words Code Description Bit Address Remarks UPS Start procedure 0 0xm150 Reserved 1 Transfer load to inverter 2 Transfer load to mains 3 UPS load off 4 Energy Saver ON 5 Energy Saver OFF 6 Eco-mode 7 Normal mode Remark: A bit set to 0 means that the control is disabled by the UPS. The control will be not executed To Send Control To Ups: Address 0x15b0, Write 1 Words For a remote UPS control, it is necessary to set the serial interface in remote mode using the Human Machine Interface. Local controls are then locked. The control table below shows if the selected control is allowed or not. If the control sent to the UPS is not allowed, the function will be ignored. Controls available by MODBUS connection: Code Control Value to write Address Remarks UPS Start procedure 1 0xm190 Reserved 2 Transfer load to inverter 4 Transfer load to mains 8 UPS load off 16 IMMEDIATE LOAD OFF!! Energy Saver ON 32 Energy Saver OFF 64 Eco-mode 128 Normal mode DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

25 10. MODBUS IN PARALLEL SYSTEM with centralised bypass Reminder In UPS parallel system configuration, there is only one MODBUS interface. The addresses mapping gives the possibility to read data from each unit and system. There is no link between the MODBUS salve number and the unit number. The interface is plugged in the com-slots in the UPS unit 1 com slots in case of modular system (see bellow). ENGLISH By-pass 1 2 MODBUS link setting The setting of the link is made from the mimic panel unit where the board is plugged. How to read data: In the MODBUS table, one part is dedicated to UPS part; it means the data from the whole system. This part is the same for each unit. Same data are present in the UPS fields addresses. BYPASS UNIT 1 UNT 2 UPS DATA = UPS DATA = UPS DATA UNIT BYPASS (15) UNIT 1 DATA UNIT 2 DATA DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 25

26 Modbus in parallel system with centralised bypass Modbus table in parallel system with centralised bypass Table Start Addresses Table Length In Words Modbus Function UPS Identification 0x READ Date and hours 0x READ UPS Configurations 0x READ UPS Status (48 bits) 0x READ UNIT Status (64 bits) 0xm READ UPS Alarms (32 bits) 0x READ UNIT Alarm (80 bits) 0xm14A 5 3 READ UPS Measurements 0x READ UNIT Measurements 0xm READ Controls permission 0xm READ UPS Controls 0xm WRITE m = number of module m = 8 m = 15 Bypass data Example: 0x3100 = ID of unit 3 0x3140 = UPS States 0xF143 = Bypass 3 states Ups Identification: Address 0x0100, 32 Words See unit part Date & Hours: Address 0x0360, 4 Words See unit part Ups Configuration: Address 0xm120, 16 Words See unit part Preliminary Remarks Following tables describe only the UPS part (common for all units) 26 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

27 Modbus in parallel system with centralised bypass Ups Status: Address 0x0140, 3 Words Code Description Bit Address Remarks S000 Load supplied by inverter 0 0x0140 S001 Load on automatic bypass 1 S002 Load on maintenance. Bypass 2 S003 Load not supplied 3 S004 Eco-mode 4 S005 Energy Saver 5 S006 UPS in normal mode 6 S007 UPS Starting procedure in progress 7 S008 UPS on maintenance bypass proc. in progress 8 S009 9 S S S S S S015 Remote control enabled 15 S016 Module 1 operating 0 0x0141 S017 Module 2 operating 1 S018 Module 3 operating 2 S019 Module 4 operating 3 S020 Module 5 operating 4 S021 Module 6 operating 5 S022 Module 7 operating 6 S023 Module 8 operating 7 S024 8 S025 9 S S S S S030 Bypass working 14 S S032 Module 1 available 0 0x0142 S033 Module 2 available 1 S034 Module 3 available 2 S035 Module 4 available 3 S036 Module 5 available 4 S037 Module 6 available 5 S038 Module 7 available 6 S039 Module 8 available 7 S046 Bypass available 14 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 27

28 Modbus in parallel system with centralised bypass Ups Alarms: Address 0x0148, 2 Words Code Description Bit Address Remarks A000 UPS imminent stop 0 0x0148 A001 UPS overload 1 A002 UPS transfer blocked 2 A003 UPS transfer impossible 3 A004 UPS insufficient Resource 4 A005 UPS Redundancy loss 5 A006 Parallel fault 6 A007 7 A008 8 A009 9 A A A A A A A016 Module 1 general 0 0x0149 A017 Module 2 general 1 A018 Module 3 general 2 A019 Module 4 general 3 A020 Module 5 general 4 A021 Module 6 general 5 A022 Module 7 general 6 A023 Module 8 general 7 A024 8 A025 9 A A A A A030 Bypass alarm 14 A DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

29 Modbus in parallel system with centralised bypass Ups Measurements: Address 0x0200, 32 Words Code Description Unit Address Format Format T015=0 T015=1 M000 Output voltage U12 V 0x0200 ### ### M001 Output voltage U23 V 1 ### ### M002 Output voltage U31 V 2 ### ### M003 Output voltage L1 V 3 ### ### M004 Output voltage L2 V 4 ### ### M005 Output voltage L3 V 5 ### ### M006 Output current L1 A 6 # ### # ###.# M007 Output current L2 A 7 # ### # ###.# M008 Output current L3 A 8 # ### # ###.# M009 Output frequency x10 Hz 9 ##.# ##.# M010 Output Power factor L1 A +/- #.## +/- #.## M011 Output Power factor L2 B +/- #.## +/- #.## M012 Output Power factor L3 C +/- #.## +/- #.## M013 Output Active Power L1 kw D # ### # ###.# M014 Output Active Power L2 kw E # ### # ###.# M015 Output Active Power L3 kw F # ### # ###.# M016 Output Apparent P. L1 kva 0x0210 # ### # ###.# M017 Output Apparent P. L2 kva 1 # ### # ###.# M018 Output Apparent P. L3 kva 2 # ### # ###.# M019 Output Crest Factor 3 #.# #.# M020 Output load rate L1 % 4 ### ### M021 Output load rate L2 % 5 ### ### M022 Output load rate L3 % 6 ### ### M023 UPS load rate % 7 ### ### M024 UPS Output power kva 8 # ### # ###.# M025 9 M026 A M027 B M028 C M029 D M030 E M031 F ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 29

30 Modbus in parallel system with centralised bypass Ups Enabled Controls Table: Address 0xm150, 2 Words Code Description Bit Address Remarks UPS Start procedure 0 0xm150 Reserved 1 Transfer load to inverter 2 Transfer load to mains 3 UPS load off 4 Energy Saver ON 5 Energy Saver OFF 6 Eco-mode 7 Normal mode Remark: A bit set to 0 means that the control is disabled by the UPS. The control will be not executed To Send Control To Ups: Address 0x15b0, Write 1 Words For a remote UPS control, it is necessary to set the serial interface in remote mode using the Human Machine Interface. Local controls are then locked. The control table below shows if the selected control is allowed or not. If the control sent to the UPS is not allowed, the function will be ignored. Controls available by MODBUS connection: Code Control Value to write Address Remarks UPS Start procedure 1 0xm190 Reserved 2 Transfer load to inverter 4 Transfer load to mains 8 UPS load off 16 IMMEDIATE LOAD OFF!! Energy Saver ON 32 Energy Saver OFF 64 Eco-mode 128 Normal mode DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

31 11. Bypass TABLE Bypass Tables Bypass Status: Address 0xF143, 4 Words Code Description Bit Address Remarks S048 Load on inverter 0 0xF143 S049 Load on auto. Bypass 1 S050 Load on maintenance Bypass 2 S051 Load not supplied 3 S052 4 S053 5 S054 Output switch 3 closed 6 S055 7 S056 8 S057 9 S S059 1 S S061 Bypass switch activated 13 S S063 Servicing alert 15 S xF144 S065 1 S066 2 S067 3 S068 4 S069 5 S070 6 S071 7 S072 Unit in normal mode 8 S073 9 S S075 1 S S S S079 Bypass in servicing mode 15 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 31

32 Bypass Tables Code Description Bit Address Remarks S080 Starting 0 0xF145 S081 Unit maintenance bypass procedure progress 1 S082 2 S083 3 S084 4 S085 5 S086 6 S087 7 S088 8 S089 9 S S091 Q4 closed 11 S092 Local maintenance bypass Q5 clos. 12 S093 Remote maintenance bypass closed 13 S S S096 Auxiliary input 1 active 0 0xF146 S097 Auxiliary input 2 active 1 S098 Auxiliary input 3 active 2 S099 Auxiliary input 4 active 3 S100 Auxiliary input 5 active 4 S101 Auxiliary input 6 active 5 S102 Auxiliary input 7 active 6 S103 Auxiliary input 8 active 7 S104 Auxiliary input 9 active 8 S105 Auxiliary input 10 active 9 S106 Auxiliary input 11 active 10 S107 Auxiliary input 12 active 11 S S S S111 Acknowledgement alarm request DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

33 Bypass Tables Bypass Alarms: Address 0xF14A, 4 Words Code Description Bit Address Remarks A032 Unit Imminent stop 0 0xF14A A033 Unit overload 1 A034 Transfer blocked 2 A035 Transfer impossible 3 A036 Insufficient Resources 4 Only on parallel A037 5 A038 6 A039 7 A040 8 A041 Bypass critical 9 A042 Common critical 10 A043 FAN alarm 11 A044 Back feed protection open 12 A045 ACS synchro source fault 13 A A A xF14B A049 1 A050 2 A051 3 A052 4 A053 5 A054 6 A055 7 A056 8 A057 9 A A A060 Bypass preventive 12 A A A A xF14C A065 1 A066 2 A067 3 A068 4 A069 5 A070 6 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 33

34 Bypass Tables Code Description Bit Address Remarks A071 7 A072 8 A073 9 A A A A A A A080 Preventive maintenance 0 0xF14D A081 1 A082 Maintenance bypass alarm 2 A083 3 A084 4 A085 5 A086 6 A087 7 A088 8 A089 9 A A A A A094 Output since xx minutes on auto bypass 14 A095 Bypass General alarm 15 A xF14E A097 1 A098 2 A099 3 A100 4 A101 Aux. input alarm 5 If set A102 6 A103 7 A104 8 A105 9 A A A A A A111 Option board alarm DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

35 Bypass Tables Bypass Measurements tables: Address 0xF220, 80 words Code Description Unit Address Format Format T015=0 T015=1 M032 Output voltage U12 V 0xF220 ### ### M033 Output voltage U23 V 1 ### ### M034 Output voltage U31 V 2 ### ### M035 Output voltage L1 V 3 ### ### M036 Output voltage L2 V 4 ### ### M037 Output voltage L3 V 5 ### ### M038 Output current L1 A 6 # ### # ###.# M039 Output current L2 A 7 # ### # ###.# M040 Output current L3 A 8 # ### # ###.# M041 Output frequency x10 Hz 9 ##.# ##.# M042 Output Power factor L1 A +/- #.## +/- #.## M043 Output Power factor L2 B +/- #.## +/- #.## M044 Output Power factor L3 C +/- #.## +/- #.## M045 Output Active Power L1 kw D # ### # ###.# M046 Output Active Power L2 kw E # ### # ###.# M047 Output Active Power L3 kw F # ### # ###.# M048 Output Apparent Power L1 kva 0xF230 # ### # ###.# M049 Output Apparent Power L2 kva 1 # ### # ###.# M050 Output Apparent Power L3 kva 2 # ### # ###.# M051 Output Crest Factor 3 #.# #.# M052 Output load rate L1 % 4 ### ### M053 Output load rate L2 % 5 ### ### M054 Output load rate L3 % 6 ### ### M055 Unit load rate % 7 ### ### M056 Unit Power S Output kva 8 # ### # ###.# M057 Unit Power P Output kw 9 # ### # ###.# M058 A M059 B M060 C M061 D M062 E M063 F M064 0xF240 M065 1 M066 2 M067 3 M068 4 M069 5 M070 6 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 35

36 Bypass Tables Code Description Unit Address Format Format T015=0 T015=1 M071 7 M072 Bypass input supply voltage U12 V 8 ### ### M073 Bypass input supply voltage U23 V 9 ### ### M074 Bypass input supply voltage U31 V A ### ### M075 Bypass input supply voltage V1 V B ### ### M076 Bypass input supply voltage V2 V C ### ### M077 Bypass input supply voltage V3 V D ### ### M078 Bypass input supply frequency x10 Hz E ###.# ###.# M079 Ambient T C F ##.# ##.# M080 0xF250 M081 1 M082 2 M083 3 M084 4 M085 M086 6 M087 7 M088 8 M089 9 M090 A M091 B M092 C M093 D M094 E M095 F M096 0xF260 M097 1 M098 2 M099 3 M100 4 M101 5 M102 6 M103 7 M104 8 M105 9 M106 A M107 B M108 C M109 D M110 E M111 F 36 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

37 12. Module TABLE Module Status: Address 0xm143, 4 Words Code Description Bit Address Remarks S048 Load on inverter 0 0xm S051 Load not supplied 3 S052 Module is available 4 S053 Module isolated from inst. 5 S054 Output switch 2 closed 6 S055 Rectifier ON 7 S056 Battery charging 8 S057 Battery charged 9 S S059 Inverter ON 11 S060 Inverter switch/contactor closed 12 S S S063 Servicing alert 15 S064 Rectifier input supply fault 0 0xm144 S065 Bypass input supply out of tolerance 1 S066 2 S067 Bypass input supply is synchro ref 3 S068 4 S069 5 S070 UPS general power off input active 6 S071 Generator set active 7 S072 Module in normal mode 8 S073 Module in eco-mode 9 S S075 Module in stand-by mode 11 S S S S079 Module in servicing mode 15 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 37

38 Module Tables Code Description Bit Address Remarks S080 Module Start procedure progress 0 0xm145 S081 1 S082 2 S083 Battery test interrupted 3 S084 Battery test in progress 4 S085 Battery test in stand-by 5 S086 6 S087 7 S088 8 S089 9 S090 Q1 closed 10 S S S S094 Q21 switch closed 14 S095 Q22 switch closed 15 S096 Auxiliary input 1 active 0 0xm146 S097 Auxiliary input 2 active 1 S098 Auxiliary input 3 active 2 S099 Auxiliary input 4 active 3 S100 Auxiliary input 5 active 4 S101 Auxiliary input 6 active 5 S102 Auxiliary input 7 active 6 S103 Auxiliary input 8 active 7 S104 Auxiliary input 9 active 8 S105 Auxiliary input 10 active 9 S106 Auxiliary input 11 active 10 S107 Auxiliary input 12 active 11 S S S S111 Acknowledgement alarm request DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

39 Module Tables Module Alarms: Address 0xm14A, 4 Words Code Description Bit Address Remarks A032 Unit Imminent stop 0 0xm14A A033 Module overload 1 A034 2 A035 3 A036 4 A037 5 A038 6 A039 Rectifier critical 7 A040 Inverter critical 8 A041 9 A042 Common critical 10 A043 FAN alarm 11 A044 Back feed protection open 12 A A A A048 Operating on battery 0 0xm14B A049 Battery alarm 1 A050 Battery room 2 A051 Battery discharged 3 A052 End of autonomy time 4 A053 Battery test failure 5 A054 Earth leakage fault 6 A055 Battery circuit open 7 A056 On battery with mains OK 8 A057 DC voltage not OK 9 A058 Rectifier preventive 10 A059 Inverter preventive 11 A A061 Common preventive 13 A062 Mimic panel 14 A063 Ambient T max 15 A064 BHC general alarm 0 0xm14C A065 1 A066 2 A067 3 A068 4 A069 5 A070 6 ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 39

40 Module Tables Code Description Bit Address Remarks A071 7 A072 8 A073 9 A A A A A A A080 Preventive maintenance 0 0xm14D A081 1 A082 2 A083 Rotation phase fault 3 A084 4 A085 5 A086 6 A087 7 A088 8 A089 9 A A A A A A095 Unit General alarm 15 A096 Fly Wheel disconnected 0 0xm14E A097 Fly Wheel Critical 1 If set A098 Fly Wheel preventive 2 A099 3 A100 4 A101 Aux. input alarm 5 If set A102 6 A103 7 A104 8 A105 9 A A A A109 kw - kva configuration Error 13 A110 Eco-mode configuration Error 14 A111 Option board alarm DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

41 Module Tables Module Measurements tables: Address 0xm220, 80 words Code Description Unit Address Format Format T015=0 T015=1 M032 Output voltage U12 V 0xm220 ### ### M033 Output voltage U23 V 1 ### ### M034 Output voltage U31 V 2 ### ### M035 Output voltage L1 V 3 ### ### M036 Output voltage L2 V 4 ### ### M037 Output voltage L3 V 5 ### ### M038 Output current L1 A 6 # ### # ###.# M039 Output current L2 A 7 # ### # ###.# M040 Output current L3 A 8 # ### # ###.# M041 Output frequency x10 Hz 9 ##.# ##.# M042 Output Power factor L1 A +/- #.## +/- #.## M043 Output Power factor L2 B +/- #.## +/- #.## M044 Output Power factor L3 C +/- #.## +/- #.## M045 Output Active Power L1 kw D # ### # ###.# M046 Output Active Power L2 kw E # ### # ###.# M047 Output Active Power L3 kw F # ### # ###.# M048 Output Apparent Power L1 kva 0xm230 # ### # ###.# M049 Output Apparent Power L2 kva 1 # ### # ###.# M050 Output Apparent Power L3 kva 2 # ### # ###.# M051 Output Crest Factor 3 #.# #.# M052 Output load rate L1 % 4 ### ### M053 Output load rate L2 % 5 ### ### M054 Output load rate L3 % 6 ### ### M055 Unit load rate % 7 ### ### M056 Unit Power S Output kva 8 # ### # ###.# M057 Unit Power P Output kw 9 # ### # ###.# M058 Rectifier input supply volt. U12 V A ### ### M059 Rectifier input supply volt. U23 V B ### ### M060 Rectifier input supply volt. U31 V C ### ### M061 Rectifier V1 V D ### ### M062 Rectifier V2 V E ### ### M063 Rectifier V3 V F ### ### M064 Rectifier input supply frequency x10 Hz 0xm240 ##.# ##.# M065 Rectifier input supply current L1 A 1 ###.# ###.# M066 Rectifier input supply current L2 A 2 ###.# ###.# M067 Rectifier input supply current L3 A 3 ###.# ###.# M068 Inverter output voltage U12 V 4 ### ### M069 Inverter output voltage U23 V 5 ### ### M070 Inverter output voltage U31 V 6 ### ### ENGLISH DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07 41

42 Module Tables Code Description Unit Address Format Format T015=0 T015=1 M071 Frequency inverter x10 Hz 7 ##.# ##.# M072 V 8 ### ### M073 V 9 ### ### M074 V A ### ### M075 V B ### ### M076 V C ### ### M077 V D ### ### M078 Hz E ###.# ###.# M079 Ambient T C F ##.# ##.# M080 Vdc + V 0xm250 ### ### M081 M082 Battery voltage string + V 2 ### ###.# M083 M084 Battery current + A 4 # ### # ###.# M085 M086 6 M087 7 M088 8 M089 9 M090 A M091 Battery T C B ##.# ##.# M092 Average battery T C C ##.# ##.# M093 Battery capacity Ah D # ### # ###.# M094 Battery capacity % E ### ### M095 Remaining backup time mn F ### ### M096 0xm260 M097 1 M098 2 M099 3 M100 4 M101 5 M102 6 M103 7 M104 8 M105 9 M106 A M107 B M108 C M109 D M110 E M111 F 42 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_07

43 Socomec UPS worldwide IN WESTERN EUROPE IN EASTERN EUROPE, MIDDLE EAST, AFRICA IN ASIA PACIFIC IN AMERICA BELGIUM Schaatsstraat, 30 rue du Patinage B Bruxelles Tel. +32 (0) info.ups.be@socomec.com FRANCE 95, rue Pierre Grange F Fontenay-sous-Bois Cedex Tel. +33 (0) dcm.ups.fr@socomec.com GERMANY Heppenheimer Straße 57 D Mannheim Tel. +49 (0) info.ups.de@socomec.com ITALY Via Leone Tolstoi, 73 - Zivido San Giuliano Milanese (MI) Tel info.ups.it@socomec.com PORTUGAL Núcleo Empresarial de Mafra II Av. Dr. Francisco Sá Carneiro, Fracção N Mafra Tel info.ups.pt@socomec.com SPAIN C/Nord, 22 Pol. Ind. Buvisa E Teià (Barcelona) Tel info.ups.sib@socomec.com THE NETHERLANDS Duwboot 13 NL CD Houten Tel. +31 (0) info.ups.nl@socomec.com UNITED KINGDOM Units 7A-9A Lakeside Business Park Broadway Lane - South Cerney Cirencester - GL7 5XL Tel. +44 (0) info.ups.uk@socomec.com OTHER COUNTRIES Tel info.ups.europe@socomec.com POLAND ul. Mickiewicza Warszawa Tel info.ups.pl@socomec.com ROMANIA Heliade Intre Vii Street no.8, 2 District Bucharest Tel ( 89, 81, 82) info.ups.ro@socomec.com RUSSIA 4th Street 8 Marta, 6A, Moscow Tel info.ups.ru@socomec.com SLOVENIA Savlje 89 SI Ljubljana Tel info.ups.si@socomec.com TURKEY Masuklar Yokusu No:57/ Besiktas Istanbul Tel info.ups.tr@socomec.com OTHER COUNTRIES Tel info.ups.emea@socomec.com AUSTRALIA Unit 3, 2 Eden Park Drive (Rydecorp) Macquarie Park NSW 2113 Tel info.ups.au@socomec.com CHINA Universal Business Park B33, 3rd Fl, 10 Jiuxianqiao Rd., Chaoyang, Beijing P.R., China Tel info.ups.cn@socomec.com INDIA B1, IInd Floor, Thiru-Vi-Ka-Industrial Estate Guindy Chennai Tel info.ups.in@socomec.com MALAYSIA 31 Jalan SS 25/41- Mayang Industrial Park Petaling Jaya.- Selangor, Malaysia Tel info.ups.my@socomec.com SINGAPORE 31 Ubi Road 1, Aztech Building # (Annex) - SG - Singapore Tel info.ups.sg@socomec.com THAILAND No.9 Soi Vibhavadirangsit 42 Vibhavadirangsit Rd, Ladyao Chatujak Bangkok Tel info.ups.th@socomec.com VIETNAM 539/23 Luy Ban Bich St., Phu Thanh Ward, Tan Phu Dist Ho Chi Minh City Tel info.ups.vn@socomec.com ASIA PACIFIC HEAD OFFICE Tel info.ups.apac@socomec.com LATIN AMERICAN COUNTRIES Tel info.ups.sib@socomec.com HEAD OFFICE SOCOMEC GROUP S.A. SOCOMEC capital R.C.S. Strasbourg B B.P , rue de Westhouse - F Benfeld Cedex SOCOMEC UPS Strasbourg 11, route de Strasbourg - B.P F Huttenheim Cedex- FRANCE Tel. +33 (0) Fax +33 (0) admin.ups.fr@socomec.com SOCOMEC UPS Isola Vicentina Via Sila, 1/3 - I Isola Vicentina (VI) - ITALY Tel Fax hr.ups.it@socomec.com SALES, MARKETING AND SERVICE MANAGEMENT SOCOMEC UPS Paris 95, rue Pierre Grange F Fontenay-sous-Bois Cedex - FRANCE Tel. +33 (0) Fax +33 (0) dcm.ups.fr@socomec.com YOUR DISTRIBUTOR Non contractual document. 2011, Socomec SA. All rights reserved. VALID FOR FRANCE VALID FOR ITALY ISO 9001 FM ISO14001 EMS

DELPHYS MX. from 800 to 900 kva. Three-phase Uninterruptible Power Supplies

DELPHYS MX. from 800 to 900 kva. Three-phase Uninterruptible Power Supplies from 800 to 900 kva Three-phase Uninterruptible Power Supplies the Mega Power protection up to 5.4 MVA Based on the technology of the 500 kva ad enhanced upon, the 800 and 900 kva is capable of a maximum

More information

NETYS PR RT VA

NETYS PR RT VA NETYS PR RT 1700-3300 VA 安装及操作手册 CN Installations- und bedienungsanleitung DE Manual de instalación y uso ES Manuel d installation et d utilisation FR Installation and operating manual GB Manuale di installazione

More information

DELPHYS MP. from 60 to 200 kva protects you up to 1200 kva. Three Phase Uninterruptible Power Systems SOCOMEC GROUP SWITCHING PROTECTION & UPS

DELPHYS MP. from 60 to 200 kva protects you up to 1200 kva. Three Phase Uninterruptible Power Systems SOCOMEC GROUP SWITCHING PROTECTION & UPS Three Phase Uninterruptible protects you up to 1200 kva SOCOMEC GROUP SWITCHING PROTECTION & UPS Three Phase Uninterruptible protects you up to 1 200 kva There are two versions to meet your requirements:

More information

SIRCO MC PV. Disconnect switches for photovoltaic applications up to 45 A, up to 1000 Vdc UL 508i & IEC

SIRCO MC PV. Disconnect switches for photovoltaic applications up to 45 A, up to 1000 Vdc UL 508i & IEC SIRCO MC PV Disconnect switches for photovoltaic applications up to 4 A, up to 1000 Vdc UL 08i & IEC 60947-3 Your guarantee for safe & reliable switching of photovoltaic circuits Taking into account the

More information

SIRCO MC PV. Solar Disconnect Switch up to 40 A, up to 1000 Vdc

SIRCO MC PV. Solar Disconnect Switch up to 40 A, up to 1000 Vdc SIRCO MC PV Solar Disconnect Switch up to 40 A, up to 1000 Vdc Your guarantee for safe & reliable switching of photovoltaic circuits Taking into account the specificity and technical constraints of solar

More information

COMO Non-fusible disconnect switches from 30 to 50 A

COMO Non-fusible disconnect switches from 30 to 50 A EDITION 2 CATALOGUE EXTRACT COMO Non-fusible disconnect switches COMO COMO_186_A The solution for > Industrial control systems Strong points COMO_185_A COMO > Easy mounting > Compact > Safety Conformity

More information

Modbus Register Map:Galaxy VM (3: kVA 400/480V)

Modbus Register Map:Galaxy VM (3: kVA 400/480V) Modbus Register Map:Galaxy VM (3:3 50-225kVA 400/480V) Part number: 990-9692 Notes:. 6-bit registers are transmitted MSB first (i.e. big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least

More information

ATyS M Modular Transfer Switching Equipment from 40 to 160 A

ATyS M Modular Transfer Switching Equipment from 40 to 160 A ATyS M Modular Transfer Switching Equipment from 40 to 160 A ATyS M The source transfer solution that combines safety and performance Socomec transfer switching equipment helps you to secure your power

More information

COUNTIS E. Energy Measurement for your installations MADE TO MEASURE

COUNTIS E. Energy Measurement for your installations MADE TO MEASURE COUNTIS E Energy Measurement for your installations MADE TO MEASURE A comprehensive range for measuring your energy efficiency Software Control Vision Designed to communicate with all the installation

More information

Enclosed switches. from 20 to 1600 A

Enclosed switches. from 20 to 1600 A Enclosed switches from 20 to 1600 A Why do you need an enclosed switch? Switchgear systems are an essential part of your electrical system. Present at all levels of your electrical distribution, they allow

More information

#+, -".#,/.0/ &%( 8('4),54, 0/ 690/:,!.5/!./4,!! 0."+;,!<!!.9.,/ >0/)! 4,. +. A),, 9 0/:,!. 5/,?" 5?? /5.'0/.>.5,/..5 B,,+

#+, -.#,/.0/ &%( 8('4),54, 0/ 690/:,!.5/!./4,!! 0.+;,!<!!.9.,/ >0/)! 4,. +. A),, 9 0/:,!. 5/,? 5?? /5.'0/.>.5,/..5 B,,+ !"#$%!"#! &' #+, -".#,/.0/ 1-20/*3)**% (-4'../".+/5/!/46&4&// 5',/%/.)*)%74 &%( 8('4),54, 0/ 690/:,!.5/!./4,!! 0."+;,!

More information

RM CC. Modular fuse holders for industrial class CC fuses

RM CC. Modular fuse holders for industrial class CC fuses RM CC Modular fuse holders for industrial class CC fuses RM CC Modular DIN rail mounted fuse holders for UL Class CC fuses The solution for Distribution boards Motor and control circuits Transformer protection

More information

SIRCOVER Manual Transfer Switching Equipment from 125 to 3200 A

SIRCOVER Manual Transfer Switching Equipment from 125 to 3200 A Manual Transfer Switching Equipment from 125 to 3200 A Why do you need Transfer Switching Equipment (TSE)? Power outages can occur, even in high reliability distribution networks, leading to major incidents

More information

Enclosed switch & safety enclosure. for local and safety breaking applications

Enclosed switch & safety enclosure. for local and safety breaking applications Enclosed switch & safety enclosure for local and safety breaking applications Secure your installation Local breaking enclosures are installed near to a motor or a machine in order to separate them from

More information

INOSYS LBS. Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications

INOSYS LBS. Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications INOSYS LBS Load Break Switches incorporating tripping function from 00 to 800 A, up to 000 VAC AC applications Safe & reliable installations Reliability and guaranteed safety combined with low maintenance

More information

Energy Storage Solution for microgrids. from 33 kva to multiple MVA

Energy Storage Solution for microgrids. from 33 kva to multiple MVA Energy Storage Solution for microgrids from 33 kva to multiple MVA For a secure and flexible network Microgrids are groups of Distributed Energy Resources (DERS) and interconnected loads controllable as

More information

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 2014 2015 SHORT FORM CATALOGUE ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 ATyS UL 1008 Motorized Transfer Switching Equipment from 100 to 400 A Transfer switches

More information

DELPHYS MX. Three-Phase UPS from 250 kva to 500 kva FOR ALL YOUR NEEDS UP TO 3000 KVA FAIL-SAFE PROTECTION: THE MAXI SOLUTION

DELPHYS MX. Three-Phase UPS from 250 kva to 500 kva FOR ALL YOUR NEEDS UP TO 3000 KVA FAIL-SAFE PROTECTION: THE MAXI SOLUTION Three-Phase UPS from 250 kva to 500 kva FOR ALL YOUR NEEDS UP TO 3000 KVA FAIL-SAFE PROTECTION: THE MAXI SOLUTION SOCOMEC GROUP SWITCHGEAR AND UPS SOCOMEC, an independent manufacturer The SOCOMEC Group

More information

DELPHYS. Operating manual GB

DELPHYS. Operating manual GB DELPHYS DS Operating manual GB UPS/NTA GB/DSEXPC1.F Certificate of Warranty The warranty conditions are stipulated in the sales contract, if not the following points shall apply. The manufacturer exclusively

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

Fuse protection solutions

Fuse protection solutions Fuse protection solutions Your challenges Our solutions Accidents involving electricity occur mainly during maintenance operations on your low-voltage systems (cabinets, enclosures, electrical outlets,

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

STATYS A Cabinet and Integrable Frame. Installation manual GB

STATYS A Cabinet and Integrable Frame. Installation manual GB STATYS 200-400-600A Cabinet and Integrable Frame Installation manual GB INDEX 1. WARRANTY CERTIFICATE 4 2. PRESENTATION 5 2. 1. Foreword 5 2. 2. The role of Statys 5 2. 3. Operating principle 5 2. 4. Product

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm

DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm Temperature 0x0100 0257 10257 OK Over Temperature Alarm

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa

StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa This document contains a battery wiring guide and on site checklist with steps for post-installation verification of a StorEdge

More information

ConceptpowerTM Modular kVA

ConceptpowerTM Modular kVA TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA

More information

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter PowerCommand ModLon II Gateway ModBus LON Converter Description The PowerCommand ModLon II Gateway is used to interface PowerCommand networks to devices and systems that communicate in Modbus communication

More information

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 19 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 9 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

60 to 160 kva.

60 to 160 kva. 60 to 160 kva www.borri.it Low TCO, efficient and compact solution for supplying reliable uninterrupted quality power to all critical applications in networking and small to medium datacenter, health,

More information

Phase Modular Finally the benefits of Modular ups are for all

Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 The MUST 30/120 is an uninteruptible power supply, three phase input/ output, ranging from 15 kva to 120 kva

More information

PowerScale TECHNICAL SPECIFICATIONS

PowerScale TECHNICAL SPECIFICATIONS PowerScale TECHNICAL SPECIFICATIONS PowerScale highlights at a glance Best in class efficiency Cost savings during the entire life-cycle(tco) Low input harmonic distortion Cost saving during installation

More information

MASTERYS TM. No-break power solutions from 8 to 90 kva FOR CRITICAL INDUSTRIAL AND COMPUTER APPLICATIONS MAKE YOUR BUSINESS SAFE

MASTERYS TM. No-break power solutions from 8 to 90 kva FOR CRITICAL INDUSTRIAL AND COMPUTER APPLICATIONS MAKE YOUR BUSINESS SAFE No-break power solutions from 8 to 90 kva FOR CRITICAL INDUSTRIAL AND COMPUTER APPLICATIONS MAKE YOUR BUSINESS SAFE SOCOMEC GROUP SWITCHGEAR AND UPS SOCOMEC, an independent manufacturer The SOCOMEC Group

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 3200 A, up to 1500 VDC UL 98B & IEC

SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 3200 A, up to 1500 VDC UL 98B & IEC SIRCO PV Disconnect switches for photovoltaic applications From 100 to 3200 A, up to 1500 VDC UL 98B & IEC 60947-3 You deserve safe & reliable PV installations As a PV expert, you are challenged to differentiate

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

Pulsar EXtreme CLA 1500C

Pulsar EXtreme CLA 1500C www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme CLA 500C Installation and user manual 503998EN/AA - Page Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

Green Power 2.0 MASTERYS GP

Green Power 2.0 MASTERYS GP Green Power 2.0 MASTERYS GP 60 to 120 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

» Sophisticated» Reliable» Intelligent

» Sophisticated» Reliable» Intelligent PowerGem Pro Series Single and Three Phase Input & Single Phase Output True Online Double Conversion UPS 6kVA 30kVA PowerGem Pro Series» Sophisticated» Reliable» Intelligent VFI The PowerGem Pro is the

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH

More information

SIRCO PV. Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC

SIRCO PV. Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC SIRCO PV Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC 60947-3 You deserve safe & reliable PV installations As a PV expert, you are challenged to differentiate

More information

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply www.eaton.com/dxups USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply CONTENTS 1.Brief introduction 1 1.1 System and model description 1 1.2 Description of commonly used symbols

More information

MASTERYS TM. No-break power solutions from 8 to 90 kva FOR CRITICAL INDUSTRIAL AND COMPUTER APPLICATIONS MAKE YOUR BUSINESS SAFE

MASTERYS TM. No-break power solutions from 8 to 90 kva FOR CRITICAL INDUSTRIAL AND COMPUTER APPLICATIONS MAKE YOUR BUSINESS SAFE No-break power solutions from 8 to 90 kva FOR CRITICAL INDUSTRIAL AND COMPUTER APPLICATIONS MAKE YOUR BUSINESS SAFE SOCOMEC GROUP SWITCHGEAR AND UPS The solution you ve been waiting for Application procedures

More information

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 400/500 kw With eboost Technology TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01

More information

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW Thank you for purchasing RS485 card/box. This manual contains instructions and warnings that should be followed during the installation, operating and storage of the card. Please keep this manual for further

More information

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS until reading through this manual carefully. Observe

More information

Industrial PFC UPS System

Industrial PFC UPS System Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The Supreme series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models

More information

Features and benefits. Applications

Features and benefits. Applications www.borri.it Low Total Cost of Ownership, high efficiency and compact solution for supplying reliable uninterrupted quality power to all critical applications in networking and medium to large data center,

More information

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM PowerLine DPA 20 120 kva Full power for industrial applications PowerLine DPA 20 120 kva Full power for industrial applications 2 ABB UPS SYSTEMS POWERLINE

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models and uses

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

Pulsar EXtreme 2200C / 3200C

Pulsar EXtreme 2200C / 3200C www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme 00C / 300C Installation and user manual P O W E R P R O V I D E R L E I B E R R U P T N T N I E U T H 3400753EN/AA - Page Introduction Thank you for selecting

More information

PowerScale kva Technical Specifications

PowerScale kva Technical Specifications PowerScale 10-50 kva Technical Specifications Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 POWERSCALE SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS... 4 10.2.1 MECHANICAL CHARACTERISTICS

More information

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10) APPLICATION NOTES Industrial Wall Control (IWC0) (English) (IWC0) The Breezair Industrial Wall Control (IWC0) is designed to provide both local and external Evaporative Air cooler control for all Breezair

More information

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

B8031FXS - B8033FXS Uninterruptible Power Supply

B8031FXS - B8033FXS Uninterruptible Power Supply B8031FXS - B8033FXS Uninterruptible Power Supply 1ph - 3ph from 10 to 20 kva Applications Networks and servers Industrial control and process automation Building automation Highlights On-line double conversion

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Content 1. Laserline series 3

Content 1. Laserline series 3 FT LASERLINE Series TECHNICAL DATA SHEET FT LASERLINE Series 1. Laserline series Content 1. Laserline series 3 2. Connectors 4 3. Control system 4 4. Options 5 4.1 Automatic flow control 5 4.2 FT communication

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company imagination at work QUITO: Elia Liut N45-26 y Edmundo Chiriboga Telf:

More information

TOP SMART intelligent position monitor:

TOP SMART intelligent position monitor: TOP SMART intelligent position monitor: Air Torque also manufacture the Top smart intrinsically safe compact valve position monitor with integrated diagnostics, self calibrating limit switches, integrated

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE

More information

U n i n t e r r u p t i b l e P o w e r S y s t e m

U n i n t e r r u p t i b l e P o w e r S y s t e m SMART ON-LINE UPS User s Manual U n i n t e r r u p t i b l e P o w e r S y s t e m Smart On-Line UPS 2KVA ~ 20KVA 20KVA Exhaust hole (16)Main breaker (12)Heat exhaust hole (15)Telephone (Rj11) or network

More information

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions Operating Instructions BKS24-9A Operating Instructions BKS24-9A Table of contents Operating Instructions 1 Operating controls and indicators 2 2 Preparations for faultless commissioning and operating 3

More information

Technical Data Sheets

Technical Data Sheets Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply

More information

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA 20FT-HC WATER-COOLED THREE PHASE 50 HZ DIESEL Generating Rates SERVICE PRP STANDBY Power kva 1296 1420 Power kw 1037 1136 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 380/220-415/240

More information

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers 250-800kVA Liebert NX Enterprise-Scale UPS Protection For Medium And Large Data Centers Efficiency. Availability. Capacity. Control. Facility managers continue to face the increasing cost of energy consumption

More information

UPS5000-E (25-75 kva) Series

UPS5000-E (25-75 kva) Series Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD. CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012 Technical Information THYRISTORS T-PH from 5A to 700A Specifications Universal Phase Thyristor Unit 55-77-03-63, March 0 GENERAL DESCRIPTION THYRISTORS T-PH is a full digital and universal Thyristor unit

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018 QUARTERS 2017-2018 June 14, 2018 CONTENTS BASEPROTOTAL BASEPROCARS BASEPROLCV BASEPROHCV BASEPROBC Summation of cars, LCVs, HCVs, heavy buses Cars LCVs HCVs Heavy buses Note: The production of cars and

More information

POWER SUPPLY FOR ASYNCHRONOUS MOTORS

POWER SUPPLY FOR ASYNCHRONOUS MOTORS White Paper 07 2010 POWER SUPPLY FOR ASYNCHRONOUS MOTORS Author: Franck Weinbissinger GENERAL INFORMATION Three-phase asynchronous motors are very robust and low-maintenance electrical machines widely

More information

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99 80-125 kva/kw E Three-Phase Double-Conversion On-Line Full Four Year Warranty www.stacoenergy.com Up to 99% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front,

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA UPS MODULAR SINGLE-PHASE from 1250 to 10000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES SINGLE PHASE MODULAR UPS Redundant modular UPS, expandable up to 10 kva with the best

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

Diesel Generator Set S3.8 Series Engine

Diesel Generator Set S3.8 Series Engine Diesel Generator Set S3.8 Series Engine > Specification Sheet 44 kva 66 kva 50Hz 40 kw 60 kw 60Hz Description This Cummins Power Generation commercial generator set is a fully integrated power generation

More information

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL Local Area NETWORKS (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Three Phase UPS Systems

Three Phase UPS Systems Three Phase UPS Systems Range: 10 to 500kVA MEDICAL PLASTIC AUTOMOBILE PULP & PAPER PACKAGING Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems

More information

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out) TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5

More information

SIRCO M and MV. Modular universal switches from 16 to 160 A THE VERSATILE SOLUTION

SIRCO M and MV. Modular universal switches from 16 to 160 A THE VERSATILE SOLUTION SRC M and MV Modular universal switches from 16 to 160 A THE VERSATLE SLUTN SCMEC : nnovators in LV switching solutions As a world leader in electrical switching and protection systems, SCMEC launches

More information

PowerCommand Paralleling Systems. Robust Paralleling System Solutions For Reliable Performance

PowerCommand Paralleling Systems. Robust Paralleling System Solutions For Reliable Performance PowerCommand Paralleling Systems Robust Paralleling System Solutions For Reliable Performance PowerCommand Paralleling Systems Power And Flexibility On Demand PowerCommand digital paralleling systems from

More information

INGENIO PLUS Uninterruptible Power Supply

INGENIO PLUS Uninterruptible Power Supply INGENIO PLUS Uninterruptible Power Supply 3ph from 30 to 160 kva Applications Small and medium data centers Networks and servers Industrial control and process automation Medical equipment Building automation

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase Local Area Networks (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery

More information

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerWave 33 Efficient power protection for today s IT and process-related work environments ARTICLE OR CHAPTER TITLE PowerWave 33 Efficient power protection for today s IT and process-related work environments Cooling fan UPS control panel Maintenance bypass isolator Input supply isolator Slot

More information

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology TLE Series UPS 750/1000 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information