CATALOG. Blackburn Flexible braids
|
|
- Cameron Erick Dennis
- 5 years ago
- Views:
Transcription
1 CAALOG Blackburn lexible braids
2 homas & Betts is now ABB Installation Products, but our long legacy of quality products and innovation remains the same. rom connectors that help wire buildings on Earth to cable ties that help put machines in space, we continue to work every day to make, market, design and sell products that provide a smarter, safer and more reliable flow of electricity, from source to socket.
3 able of contents Blackburn flexible braids 012 Index
4 4 BLACKBURN LEXIBLE BRAID lexible braid ype B lexible braids lexible braid in a roll 10-foot minimum Cat. no. Circular mils hickness (in.) idth (in.) BBRL BCRL BDRL BXDRL errules or lugs not included. lexible copper braids for use in substation and grounding applications. in-plated copper braids and ferrules for high conductivity and corrosion resistance Enables linear expansion, equipment vibration and offset connections Certified C22.2 no. 41 grounding and bonding equipment Listed UL467 and UL486A grounding and bonding equipment ype B lexible braids Cat. no. Circular mils Bolt hole (in.) No. of braids in ferrule hickness Dimensions (in.) C D E idth errule length Distance ctr. to ctr. BB12-1* BC12-1* BD12-1* BD12* B2D12-1* B2D12* B3D12-1* B3D12* BXD12-1* BXD12* B2XD12-1* B2XD B3XD12-1* B3XD12* BE12-1* BE12* B2E12-1* B2E12* B3E B4E B B B B BG B2G B3G B4G Diagram C D E Catalog number shown in 12" lengths. tandard lengths offered in 6, 12, 18, 24, 30 and 36 inches (end to end). Change the 12 in the above catalog numbers to the desired length. (-1) indicates one bolt hole per ferrule. ee amperage tables on next page as a reference for grounding and bonding, or continuous current applications. B4 series is not listed/certified. or custom flexible braids, contact customer service.
5 LEXIBLE BRAID ELECION GUIDE & GROUNDING AND BONDING APPLICAION 5 lexible braid lexible braid selection guide & grounding and bonding applications Minimum size flexible braid for continuous-current applications Cat. no. Circular mils Amperage capacity Cat. no. Circular mils Amperage capacity BB BE BC BE BD B2E BD B2E B2D B3E B2D B4E B3D B B B BXD B BXD B B2XD BG B2XD B2G B3XD B3G B3XD B4G Grounding and bonding applications Minimum size conductors for bonding raceways and equipment Rating or setting of overcurrent device in circuit ahead of equipment, conduit, etc. not exceeding amps Copper wire circular mils (6 AG) (4 AG) (3 AG) (2 AG) (1 AG) (1/0 AG) (2/0 AG) (3/0 AG) (4/0 AG) Based on table 16 C.E.C. Minimum size of bare copper grounding conductor Maximum available in short circuit current amps Maximum fault duration with exothermic weld, compression or bolted joint 0.5 seconds circular mils 1.0 second circular mils Based on table 51 C.E.C. ize calculated in accordance with IEEE No. 80.
6 6 BLACKBURN LEXIBLE BRAID lexible braid 1-ole NEMA extra-flexible jumpers BE1 series Connect transformers, generators or busbars wherever there is severe vibration or misalignment. 36 AG individual wires in braid construction for extra flexibility 99.9% pure copper ferrules on each end provide high conductivity Individual wires are tinned prior to weaving to deliver maximum protection from corrosion 1-ole NEMA extra-flexible jumpers BE1 series Cat. no. Ampacity Δ 65 C* No. of braids in assembly 2 BE1035A (38.1) (38.1) 9 16 (14.3) 3 16 (4.7) 0.49 (0.22) BE1035A2 9 BE1035A3 7 7 BE1050A (38.1) (38.1) 9 16 (14.3) 1 4 (6.4) 0.84 (0.38) BE1050A2 9 BE1050A3 7 7 BE1070A (38.1) (38.1) 9 16 (14.3) 3 8 (9.5) 1.54 (0.70) BE1070A2 9 BE1070A3 7 7 BE1100A (39.6) (39.6) 9 16 (14.3) 1 2 (12.7) 2.31 (1.05) BE1100A2 9 BE1100A3 7 7 eight lb. (kg) Diagram 2 12" ee length information * emperature rise test per CEI60694, IEEE/ANI C Note: tandard total lengths are 12". or different lengths, add your desired length to the end of the catalog number (e.g., BE1035A1-16 for 16" long). errules are tinned. or other options, please consult your ABB representative.
7 2-OLE NEMA EXRA-LEXIBLE JUMPER BE2 ERIE 7 lexible braid 2-ole NEMA extra-flexible jumpers BE2 series Connect your equipment in high-vibration areas. 36 AG individual wires in braid construction for extra flexibility 99.9% pure copper ferrules on each end provide high conductivity Individual wires are tinned prior to weaving to deliver maximum protection from corrosion 2-ole NEMA extra-flexible jumpers BE2 series Cat. no. Ampacity Δ 65 C* No. of braids in assembly E BE2040A (38.1) (38.1) 5 8 (15.9) (44.4) 9 16 (14.3) 3 16 (4.7) 0.63 (0.286) BE2070A (38.1) 1 4 (6.4) 0.97 (0.440) BE2090A (38.1) (8.7) 1.30 (0.590) BE2110A (38.1) 3 8 (9.5) 1.66 (0.753) BE2150A (38.1) 1 2 (12.7) 2.26 (1.025) BE2170A (39.6) 3 4 (19) 3.71 (1.683) BE2200A (39.6) 1 (25.4) 5.21 (2.363) eight lb. (kg) Diagram E E 12" * emperature rise test per CEI60694, IEEE/ANI C Note: tandard total lengths are 12". or different lengths, add your desired length to the end of the catalog number (e.g., BE2040A1-16 for 16" long). errules are tinned. or other options, please consult your ABB representative.
8 8 BLACKBURN LEXIBLE BRAID lexible braid 4-ole NEMA extra-flexible jumpers BE4 series Misalignments? Now you can properly connect your equipment. 36 AG individual wires in braid construction for extra flexibility 99.9% pure copper ferrules on each end provide high conductivity Individual wires are tinned prior to weaving to deliver maximum protection from corrosion 4-ole NEMA extra-flexible jumpers BE4 series Cat. no. Ampacity Δ 65 C* No. of braids in assembly BE4140A (76.2) 3 (76.2) (44) 9 16 (14.3) 1 4 (6.4) 1.91 (0.866) BE4150A (76.2) 3 (76.2) (8.7) 2.57 (1.166) BE4235A (95.3) 4 (101.6) 3 8 (9.5) 4.00 (1.814) BE4245A (95.3) 4 (101.6) 1 2 (12.7) 5.32 (2.413) BE4250A (92.1) 4 (101.6) 5 8 (15.9) 6.60 (2.994) BE4340A (101.6) 4 (101.6) 7 8 (22.2) (5.153) BE4400A (101.6) 4 (101.6) (28.6) (7.062) eight lb. (kg) Diagram 12" * emperature rise test per CEI60694, IEEE/ANI C Note: tandard total lengths are 12". or different lengths, add your desired length to the end of the catalog number (e.g., BE4140A1-16 for 16" long). errules are tinned. or other options, please consult your ABB representative.
9 1-OLE NEMA LEXIBLE JUMPER B1 ERIE 9 lexible braid 1-ole NEMA flexible jumpers B1 series Get the flexibility you need to connect transformers, generators or busbars. 30 AG individual wires in braid construction for extra flexibility 99.9% pure copper ferrules on each end provide high conductivity Individual wires are tinned prior to weaving to deliver maximum protection from corrosion 1-ole NEMA flexible jumpers B1 series Cat. no. Ampacity Δ 65 C* 2 B1035A (31.8) (38.1) 9 16 (14.3) 1 4 (6.4) 0.48 (0.218) B1035A (31.8) (38.1) 9 B1035A (31.8) (38.1) 7 7 B1055A (34.9) (38.1) 9 32 (5.6) 0.63 (0.286) B1055A (34.9) (38.1) 9 B1055A (34.9) (38.1) 7 7 B1070A (38.1) (38.1) 9 16 (14.3) 1 4 (6.4) 0.95 (0.431) B1070A (38.1) (38.1) 9 B1070A (38.1) (38.1) 7 7 B1070A4 2 (50.8) 2 (50.8) 9 16 (14.3) B1100A (44.4) 2 (50.8) 9 16 (14.3) 1 2 (12.7) 1.23 (0.558) B1100A (44.4) 2 (50.8) 9 B1100A (44.4) 2 (50.8) 7 7 eight lb. (kg) Diagram 2 12" * emperature rise test per CEI60694, IEEE/ANI C Note: tandard total lengths are 12". or different lengths, add your desired length to the end of the catalog number (e.g., B1035A1-16 for 16" long). errules are tinned. or other options, please consult your ABB representative.
10 10 BLACKBURN LEXIBLE BRAID lexible braid 2-ole NEMA flexible jumpers B2 series hese 2-hole jumpers make connections wherever there is severe vibration. 30 AG individual wires in braid construction for flexibility with connections 99.9% pure copper ferrules on each end provide high conductivity Individual wires are tinned prior to weaving to deliver maximum protection from corrosion 2-ole NEMA flexible jumpers B2 series Cat. no. Ampacity Δ 65 C* No. of braids in assembly E B2040A (38.1) (88.9) 5 8 (15.9) (44.4) 9 16 (14.3) 3 16 (4.7) 0.63 (0.286) B2070A (38.1) 1 4 (6.4) 0.98 (0.445) B2090A (38.1) (8.7) 1.31 (0.594) B2110A (38.1) 3 8 (9.5) 1.67 (0.757) B2150A (38.1) 1 2 (12.7) 2.29 (1.039) B2170A (39.6) 3 4 (19) 3.76 (1.706) B2200A (39.6) 1 (25.4) 5.26 (2.386) eight lb. (kg) Diagram E E 12" * emperature rise test per CEI60694, IEEE/ANI C Note: tandard total lengths are 12". or different lengths, add your desired length to the end of the catalog number (e.g., B1035A1-16 for 16" long). errules are tinned. or other options, please consult your ABB representative.
11 4-OLE NEMA LEXIBLE JUMPER B4 ERIE 11 lexible braid 4-ole NEMA flexible jumpers B4 series Make the most secure connections wherever there is severe vibration or misalignment. 30 AG individual wires in braid construction for flexibility with connections 99.9% pure copper ferrules on each end provide high conductivity Individual wires are tinned prior to weaving to deliver maximum protection from corrosion 4-ole NEMA flexible jumpers B4 series Cat. no. Ampacity Δ 65 C* 2 2 B4130A (76.2) 3 (76.2) (44.4) 9 16 (14.3) (44.4) 9 16 (14.3) 1 4 (6.4) 1.93 (0.875) B4130A (44.4) 9 16 (14.3) (38.1) 7 B4130A (38.1) (38.1) 7 B4150A (44.4) 9 16 (14.3) (44.4) 9 16 (14.3) 5 16 (7.9) 2.62 (1.188) B4150A (44.4) 9 16 (14.3) (38.1) 7 B4150A (38.1) (38.1) 7 B4215A (44.4) 9 16 (14.3) (44.4) 9 16 (14.3) 3 8 (9.5) 3.31 (1.501) B4215A (44.4) 9 16 (14.3) (38.1) 7 B4215A (38.1) (38.1) 7 B4235A (44.4) 9 16 (14.3) (44.4) 9 16 (14.3) 1 2 (12.7) 4.69 (2.127) B4235A (44.4) 9 16 (14.3) (38.1) 7 B4235A (38.1) (38.1) 7 eight lb. (kg) Diagram " 2 * emperature rise test per CEI60694, IEEE/ANI C Note: tandard total lengths are 12". or different lengths, add your desired length to the end of the catalog number (e.g., B4130A1-16 for 16" long). errules are tinned. or other options, please consult your ABB representative.
12 12 BLACKBURN LEXIBLE BRAID Appendix Part number index Cat. no. Page Cat. no. Page B2D BE4250A1 8 B2D BE4340A1 8 B2E BE4400A1 8 B2E B B BG B2G B1035A1 9 B2XD B1035A2 9 B2XD B1035A3 9 B312 5 B1055A1 9 B3D12 4 B1055A2 9 B3D B1055A3 9 B3E B1070A1 9 B B1070A2 9 B3G B1070A3 9 B3XD B1070A4 9 B3XD B1100A1 9 B4E B1100A2 9 B B1100A3 9 B4G B2040A1 10 BB B2070A1 10 BBRL 4 B2090A1 10 BC B2110A1 10 BCRL 4 B2150A1 10 BD B2170A1 10 BD B2200A1 10 BDRL 4 B4130A1 11 BE B4130A2 11 BE B4130A3 11 BE1035A1 6 B4150A1 11 BE1035A2 6 B4150A2 11 BE1035A3 6 B4150A3 11 BE1050A1 6 B4215A1 11 BE1050A2 6 B4215A2 11 BE1050A3 6 B4215A3 11 BE1070A1 6 B4235A1 11 BE1070A2 6 B4235A2 11 BE1070A3 6 B4235A3 11 BE1100A1 6 BXD BE1100A2 6 BXD BE1100A3 6 BXDRL 4 BE2040A1 7 BE2070A1 7 BE2090A1 7 BE2110A1 7 BE2150A1 7 BE2170A1 7 BE2200A1 7 BE4140A1 8 BE4150A1 8 BE4235A1 8 BE4245A1 8
13 NOE 13 Notes
14 14 BLACKBURN LEXIBLE BRAID Additional information e reserve the right to make technical changes or modify the contents of this document without prior notice. ith regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. e reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG.
15
16 U ABB Installation Products Electrification Products division 860 Ridge Lake Blvd. Memphis, N tnb.abb.com Copyright 2018 ABB. All rights reserved. pecifications subject to change without notice. 7KK REV A
PRODUCT BROCHURE. Steel City solid brass and aluminum floor box covers
PRODUCT BROCHURE Steel City solid brass and aluminum floor box covers 1 TY-RAP HIGH-PERFORMANCE CABLE TIES Innovative cover design Patented hingeless design features a tethered lid that can be rotated
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationEngineered installation products Solutions for control panel applications
Engineered installation products Solutions for control panel applications 2 Engineered installation products Solutions for control panel applications Solutions for control panel applications ABB introduces
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationAF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits
More informationAF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationFuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A Efficient protection of voltage transformer circuits Extending the lifetime of installed electrical
More informationZX-Family Gas-insulated medium voltage switchgear
ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units
ABB MEASUREMENT & ANALYTICS DATA SHEET Series 4234-500 and 4234-600 Katharometer power supply units 2 SE RIE S 4 23 4-500 AN D 4 23 4-600 K ATHAROME TE R POWE R SU PPLY U NITS DS/4 23 4-E N RE V. F Measurement
More informationProduct Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant
Product Brochure Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Introduction General The braking switch serves the purpose of electrical braking a machine in a hydro or pumped
More informationZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link
Technical Datasheet SNK656D0 Catalogue Page ZS-ST Screw Clamp Terminal Blocks Test disconnect with sliding link - Secure your disconnect operations in control circuits with the robust sliding link operated
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets
Technical Datasheet SNK603D00 Catalogue Page SNK6038S00 ZK.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets The flexible solution for fitting the component of your choice in series
More informationFuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440
More informationUS CATALOG. ProLine Panelboard and breakers
US CATALOG ProLine Panelboard and breakers 2 PROLINE PANELBOARD AND BREAKERS PROLINE PANELBOARD AND BREAKERS 3 Table of contents 004 006 Description and features 007 008 Guides: and breaker placement 009
More informationZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever
Technical Datasheet SNK6D0 Catalogue Page ZS-S-R2 Screw Clamp Terminal Blocks Disconnect with lever Simplify the disconnect operations for the disconnect terminal blocks installed next to fuse terminal
More informationZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral
Technical Datasheet SNK6047D00 Catalogue Page ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral Simplify your PE.N connection with ZS35-PE block connected to ZS35-BL through a premounted jumper. SNK6063F004
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet 1SNK166D001 Catalogue Page ZS-SF1-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied with
More informationMEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage
More informationUncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA
Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA The next generation MCB for UL/CSA applications within the proven System pro M compact
More informationDBL distribution blocks 3x1 pole
TECHNICAL DATASHEET 1SNC166019D0201 - CATALOGUE PAGE 1SNC166020S0201 DBL distribution blocks 3x1 pole 84.6 3.33" 25 0.98" 32.5 1.28" 28.2 1.11" 23.5 0.93" 14.7 0.58" 36.3 1.43" 75 2.95" 62 2.44" 50.7 2"
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket
Technical Datasheet 1SNK1659D01 Catalogue Page 1SNK160S01 ZK2.5-SP-P PI-Spring Terminal Blocks Disconnect with plug - with test socket The flexible solution for fitting the component of your choice in
More informationABB cable glands SCG series Stainless Steel 316L, general purpose cable glands
1 TEHNIL DT SHEET cable glands SG series Stainless Steel 316L, general purpose cable glands Stainless steel cable glands for general purpose use, OEM, industrial and commercial applications, where a high
More informationBRIDGE-BOY Load limitation electronics with 1 or 3 set points
Change from one to two columns Data Sheet DS/BRIDGE-BOY-LCI-EN Rev. A BRIDGE-BOY Load limitation electronics with 1 or 3 set points Electronics with 1 or 3 set points designed, in combination with a load
More informationTECHNICAL CATALOG. ReliaGear SafeT interiors OEM power distribution interiors for panelboards and switchboards
TECHNICAL CATALOG ReliaGear SafeT interiors OEM power distribution interiors for panelboards and switchboards 2 R E L I A G E A R S A F E T I N T E R I O R S ABB s strong heritage of innovation, excellence
More informationZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator
Technical Datasheet SNK605D00 Catalogue Page SNK60S00 ZK.5-SF-R PI-Spring Terminal Blocks For 5x0 fuses - with blown fuse indicator - Protect your circuits with 5x0 fuse terminal blocks compliant with
More informationZK2.5-D-CH PI-Spring Terminal Blocks Component holder
Technical Datasheet SNK6066D00 Catalogue Page ZK.-D-CH PI-Spring Terminal Blocks Component holder Protect your circuit with one N4007 diode. SNK60V004 SNK009F0000 3D CAD outline drawings available on "Control
More informationZK6 PI-Spring Terminal Blocks Feed-through
Technical Datasheet SNK69D0 Catalogue Page SNK69S0 ZK6 PI-Spring Terminal Blocks Feed-through Combine high performance with compact dimensions: - 000 V AC / DC IEC 600 V UL, - Opt for the best marking
More informationZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses
Technical Datasheet SNK60D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For x 0 fuses - Protect your circuits with x0 fuse terminal blocks compliant with IEC 607-7-3 standard (fuse not supplied with
More informationZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses
Technical Datasheet SNK6D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For 5 x 0 and 5 x 5 fuses Protect your circuit with 5x5 and 5x0 fuse terminal blocks, compliant with IEC 607-7-3 standard (fuse
More informationZX-Family Gas-insulated medium voltage switchgear
ZX-Family Gas-insulated medium voltage switchgear Durable and reliable Minimum overall costs Safety first ZX offers maximum economy Sealed gas compartments The compact design of the panels reduces the
More informationABB central inverters PVS to 2091 kva
SOLAR INVERTERS ABB central inverters PVS980 1818 to 2091 kva 01 ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators
More informationContact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France
Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
More informationZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit
Technical Datasheet SNK607D00 Catalogue Page SNK607S00 ZS4-D-S-T Screw Clamp Terminal Blocks Double deck with disconnect circuit with test socket screws and feed-through circuit Find the same functionalities
More informationZK4-PE PI-Spring Terminal Blocks Ground
Technical Datasheet SNK60D00 Catalogue Page SNK60S00 ZK-PE PI-Spring Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact:
More informationMini contactors B6, BC6 with 3 pole
Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,
More informationZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections
Technical Datasheet SNK60D00 Catalogue Page SNK605S00 ZK.5-P PI-Spring Terminal Blocks Feed-through with connections Find all the features of the ZK.5 terminal block with the added option of distributing
More informationMEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices
MEDIUM VOLTAGE PRODUCTS The worldʼs fastest switching devices 2 FAULT CURRENT LIMITERS THE WORLDʼ S FASTETST SWITCHING DEVICES The worldʼs fastest switching devices ABBʼs fault current limiters disconnect
More informationSU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489
MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277
More informationInsulated crimp terminals For reliable device connection
E L EC T R I FI C AT I O N P R O D U C T S, I N S TA L L AT I O N P R O D U C T S Insulated terminals For reliable device connection ELECTRIFICATION PRODUCTS AUSTRALIA AND NEW ZEALAND Spec-Kon Wire terminals
More informationZS10-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK606D00 Catalogue Page ZS0-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail
More informationZP2.5-PE Spring Terminal Block Ground
Technical Datasheet 1SNK162002D0201.indd 08/06/11 ZP2.5-PE Spring Terminal Block Ground Catalogue Page Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail
More informationZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections
Technical Datasheet SNK663D00 Catalogue Page SNK667S00 ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections - Recommended for energy markets and highly demanding applications requiring that
More informationLENGTH 1 3 / /2" Wide Braided Connectors ( T Y P )
w a t t e r e d g e. c o m BRAIDED FLEXIBLE CONNECTORS Technical Specifications Standard Braids LENGTH 9 /16 S t a n d a rd Braids are available in 1, 1 1 /, 1 3 /8, 1 1 /2, 2,, 4, 5 and 6 width. Drilling
More information2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic
Technical Information TI/266LT-EN Rev.A 2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic Measurement Made Easy Engineered solutions for all applications Improved
More informationZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit
Technical Datasheet SNK6040D00 Catalogue Page SNK604S00 ZK.-D-PE PI-Spring Terminal Blocks Double deck with ground circuit Improve the safety of your installation in the event of a short-circuit thanks
More informationZS4-D-CH Screw Clamp Terminal Blocks Component holder
Technical Datasheet SNK6090D00 Catalogue Page ZS4-D-CH Screw Clamp Terminal Blocks Component holder Protect your circuit with one N4007 diode. SNK64V004 SNK008F0000 3D CAD outline drawings available on
More informationZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit
Technical Datasheet SNK649D00 Catalogue Page ZS6-D-PE Screw Clamp Terminal Blocks Double deck with ground circuit - Save space with double deck ground terminal blocks aligned with ZS6-D double deck terminal
More informationZS4-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK6D00 Catalogue Page SNK6S00 ZS4-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationValve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat
Data Sheet 10/14-5.32-EN Valve Blocks For direct flanging to pressure and differential pressure transmitters Drop-forging housing Replaceable valve seat Valve stem with back-flow seal and crimped valve
More informationZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator
Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse
More informationZS50-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK607D00 Catalogue Page ZS0-PE Screw Clamp Terminal Blocks Ground - Reliable electrical and mechanical contact with the rail that exceeds the requirements of the IEC 60947-7- terminal
More informationZP2.5-4P Spring Terminal Block Feed-through
Technical Datasheet 1SNK162005D0201.indd 08/06/11 ZP2.5-4P Spring Terminal Block Feed-through Catalogue Page Thanks to the ZP2.5-4P, PI-Spring terminal block: Save time and connect directly rigid and flexible
More informationZS6 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK6008D00 Catalogue Page ZS6 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 6 mm² (without insulated ferrule, CB certified) 0 AWG in just 6 mm 0.36
More informationSACE Emax 2/ML Low-voltage air circuit breakers for naval applications
LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up
More informationZS35 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK609D00 Catalogue Page ZS3 Screw Clamp Terminal Blocks Feed-through Closed terminal block: - No end section needed, - Optimized rigidity, - Perfectly adapted to solar applications:
More informationBaldor-Reliance Food Safe Stainless steel NEMA motors
FOOD & BEVERAGE Baldor-Reliance Food Safe Stainless steel NEMA motors Food safety first priority of design Reliability in intense cleaning environments Worker safety from installation through operation
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationZS10 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK6004D00 Catalogue Page SNK6004S00 ZS0 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 0 mm² (CB certified) 6 AWG in just 8 mm 0. in spacing. SNK6008F004
More informationZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits
Technical Datasheet 1SNK1107D001 Catalogue Page 1SNK1107S001 ZS4-T Screw Clamp Terminal Blocks Triple deck with feed-through circuits Save space: independent circuits in just. mm 0.0 in spacing, - Fit
More informationZS4-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK600D00 Catalogue Page ZS4-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail
More informationZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections
Technical Datasheet 1SNK16D01 Catalogue Page 1SNK1641S01 ZK.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections Improve the safety of your installation in the event of a short-circuit thanks to
More informationShut-off valves and accessories for pressure measuring instruments
Data Sheet 10/14-4.31-EN Shut-off valves and accessories for pressure measuring instruments Non-replaceable seat and plug Application Shut-off valves for pressure measuring instruments are designed for
More informationZS4 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK60D0 Catalogue Page SNK60S0 ZS4 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 4 mm² (CB certified) AWG in just. mm 0. in spacing. SNK60F00 SNK0000F0000
More informationTwinLine The new system of wall-mounting and floor-standing cabinets
04 2012 TwinLine The new system of wall-mounting and floor-standing cabinets 04 2012 TwinLine The new system of wall-mounting and floor-standing cabinets 2 2CPC 000 170 L0201 TwinLine The new system of
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationUS Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager
US Panorama New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager Circuit breakers switch power SACE Emax 2 manages it Emax 2 is the new benchmark of power circuit breakers that not only monitors
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informationZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections
Technical Datasheet 1SNK161D01 Catalogue Page 1SNK165S01 ZK.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections Find all the features of the ZK.5 terminal block with the added option of distributing
More informationLow voltage capacitors CLMD Improving power factor and enhancing power quality of your network
PRODUCT BROCHURE Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network s.a. ABB n.v. Power Quality Products Allée Centrale 10 Z.I. Jumet B-6040 Charleroi (Jumet)
More informationZS4-PE Screw Clamp Terminal Blocks Ground
Technical Datasheet SNK60D0 Catalogue Page SNK60S0 ZS4-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact:
More informationElectrification Products United Kingdom. Buildings & Infrastructure Enhanced energy efficiency & performance
Electrification Products United Kingdom Buildings & Infrastructure Enhanced energy efficiency & performance About ABB Let s write the future together ABB is a pioneering technology leader that works closely
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Definite Purpose Contactors Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability.
More informationMEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 80 C85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationManual motor starter magnetic only MO325
Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF
More informationNF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationVER: ABB Welcome M2305 Switch actuator
Pos: 2 /DinA4 - Anl eitungen Online/Inhalt/KNX/DoorEntry /83220-AP- xxx/tit elblat t - 832 20-AP-xxx - ABB @ 19\m od_ 132 3249 806 476 _15. docx @ 11 108 4 @ @ 1 === E nde der Liste für Tex tma rke C over
More informationMEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 80 D85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 D85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2
More informationMEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 250 B1 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C184; KECA 80 C216 CURRENT SENSORS INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope
More informationZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator
Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse
More informationZX2 Gas-insulated medium voltage switchgear
Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters
More informationManual motor starters Overview and benefits
Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection
More informationDODGE MECHANICAL. Grain industry Delivering solutions that solve industry challenges
DODGE MECHANICAL Grain industry Delivering solutions that solve industry challenges 2 GRAIN INDUSTRY DELIVERING SOLUTIONS THAT SOLVE INDUSTRY CHALLENGES Mechanical power transmission products We help feed
More informationEC Gold Series Synchronous permanent magnet motor
PRODUCT CATALOG Synchronous permanent magnet motor Synchronous permanent magnet motor 2 EC GOLD SERIES SYNCHRONOUS PERMANENT MAGNET MOTOR Synchronous permanent magnet motor 3 High performance in compact
More informationOrchestrate your entire home from a single interface. The beauty of interoperability.
ABB-free@home A fully customizable, complete smart home solution that takes care of everything, from climate and lighting to door entry and entertainment. 2 ABB-FREE@HOME SMARTER THAN SMART COMPLETE HOME
More informationTRANSMISSION SYSTEMS
TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric
More informationZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections
Technical Datasheet 1SNK167D01 Catalogue Page 1SNK16S01 ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections Find all the features of the ZK4 terminal block with the added option of distributing
More informationWhen grids get smart ABB your partner for developing Smart Grids solutions
When grids get smart ABB your partner for developing Smart Grids solutions A transition from traditional to Smart Grids ABB`s commitment to Smart Grids The traditional power grid is based on centralized
More informationSafety interlock switch MKey
Safety interlock switch MKey MKey are mechanical safety switches used for monitoring doors and hatches. The switch is mounted on the frame and the actuator key on the moving part of the guard. All MKey
More informationContact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series
Contact us Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series We provide motors and generators, services and expertise to save energy and
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationLow voltage bushings for pad-mounted distribution transformers Technical information guide
Transformer components Low voltage bushings for pad-mounted distribution transformers Technical information guide ABB low voltage bushings terminate a transformer s internal low voltage leads at the tank
More informationPRODUCT BROCHURE. Elastimold advanced connection system (shear bolt)
PRODUCT BROCHURE Elastimold advanced connection system (shear bolt) 2 ELASTIMOLD ADVANCED CONNECTION SYSTEM (SHEAR BOLT) Elastimold cable accessories The Elastimold advanced connection system shear bolt
More information