1 Technical Datasheet SNK6090D00 Catalogue Page ZS4-D-CH Screw Clamp Terminal Blocks Component holder Protect your circuit with one N4007 diode. SNK64V004 SNK008F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC70044 F0000 Screw Clamp Terminal Blocks 4 mm² AWG Ordering Details Color Grey Grey. mm 0.0 in Spacing Type Order Code EAN Code Pack (ing) Weight ( pce) g ZS4-D-CH-UD SNK04R Declarations and Certificates CE RoHS USR CNR CSA EAC

2 Declarations and Certificates CE CE SND08U0* RoHS USR CNR RoHS USR CNR SND306F0* SND6040A0* CSA CSA SND6070A0* EAC EAC SND6009A* Explosive Atmosphere: ATEX Classification Group Category Protection Method In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information Wire stripping length TH 3-7., TH 3- Denudage IP0 TH 3-7., TH 3- NEMA Ex e: increased security The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail IEC mm in Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 3. mm 0.38 in 0.6 N.m.3 N.m ± 0. N.m ± 0.88 N.m Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL94 V0 NF F 60 IF Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter mm² mm² mm² mm² A3-B3 IEC Needle flame testec Compliant Screw clamp 4... AWG 4... AWG AWG 3 mm 0.8 in Ferrule 4.7 mm 0.8 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²). Technical Datasheet SNK6090D00 ABB

3 Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors mm² AWG Flexible conductors mm² Flexible conductors with twin ferrule mm² AWG Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²) Cross section Rated cross section 4 mm² AWG Maximum Cross section 4 mm² AWG Electrical characteristics Current Rated current 9 A Field and factory wiring Cat. UL 09 0 A Factory wiring Cat. UL 09 CSA-C-. n 8 0 A Maximum Exe current IEC/EN Rated short-time withstand current s (Icw) 480 A Short-time withstand current 60 A 0. s s 0 s 30 s min 348 A 6 A 4 A 87 A Rated short-circuit withstand current UL 09 Max. current (4 temperature increase) / Max. cross section (mm²) 9 A Maximum short circuit current (s) 480 A 4 mm² Short Circuit Current Rating (SCCR) SA UL 09 supplement SCCR UL 09 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK RK G CC Voltage Rated voltage IEC V Rated voltage UL V Use Group UL 09 B, C Rated voltage CSA-C-. n V Rated voltage Ex e IEC/ EN Rated impulse withstand voltage IEC Dielectric test voltage IEC V Pollution degree IEC Overvoltage category IEC III ABB Technical Datasheet SNK6090D00 3

4 Temperature range Ambient temperature min/max Storage C Installing C Service C F F F Current Derating curve for continuous service temperature SNK00084F0000 Dissipated power Maximum dissipated power at rated current Maximum dissipated power at maximum Exe current IEC W IEC Rated power dissipation at an ambient temperature of 3 C - IEC Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC Compliant Temperature +00 C 96 h IEC Compliant Temperature + C Relative humidity Number of cycles ( cycle = 4h) IEC Compliant Temperature -40 C 96 h IEC Temperature Relative humidity Corrosion Salt mist IEC Compliant 96 h Concentration % SO ISO 6988 Compliant 48 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC Number of the test method Compliant 3 j 4 Technical Datasheet SNK6090D00 ABB

5 Vibrations and shocks Sinusoidal vibrations IEC Compliant Frequency range 0... Hz Number of cycles 0 Acceleration 0 m/s² Functional random vibrations IEC 6373 Category Class B 3 axes Frequency range Acceleration Long life testing at increased random vibrations Category Class B 3 axes Shock Category Class B 3 axes ZS4-D-CH Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. IEC 6373 Frequency range Acceleration IEC 6373 Acceleration Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB04790R End Sections End Stops Circuit Separators Circuit Separators Test Connectors Test Connectors Test Adapters Test Adapters Component Plugs Shield Connectors Protecting Covers Tools MC MC-YL MCPA PROCAP UMH SAT PR3.G PR4 PR PR30 PR3.Z ES4-D BAZH SCFCV4 SCFCV TC TC-R TP TP4 PG-R SHB CPV4- PS-3 JB- JB-3 JB-4 JB- JB-0 JB-0 SNK40000R0000 SNK40004R0000 SNK49999R0000 SNK900609R0000 SNK9006R0000 SNK90064R0000 SNA64800R0300 SNA6800R00 SNA68700R00 SNA730R000 SNA74300R700 SNK0960R0000 SNK9000R0000 SNA6797R300 SNA6798R400 SNK90000R0000 SNK9000R0000 SNK90003R0000 SNK9000R0000 SNK900403R0000 SNK90060R0000 SNA7679R00 SNK90060R0000 SNK9030R0000 SNK90303R0000 SNK90304R0000 SNK9030R0000 SNK9030R0000 SNK9030R ABB Technical Datasheet SNK6090D00

6 Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F Chassieu cedex / France Tel. +33 (0)4 7 7 Fax +33 (0) Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SNK6090D00 - PDF

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder Technical Datasheet SNK6066D00 Catalogue Page ZK.-D-CH PI-Spring Terminal Blocks Component holder Protect your circuit with one N4007 diode. SNK60V004 SNK009F0000 3D CAD outline drawings available on "Control

More information

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit Technical Datasheet SNK607D00 Catalogue Page SNK607S00 ZS4-D-S-T Screw Clamp Terminal Blocks Double deck with disconnect circuit with test socket screws and feed-through circuit Find the same functionalities

More information

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit Technical Datasheet SNK649D00 Catalogue Page ZS6-D-PE Screw Clamp Terminal Blocks Double deck with ground circuit - Save space with double deck ground terminal blocks aligned with ZS6-D double deck terminal

More information

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses Technical Datasheet SNK60D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For x 0 fuses - Protect your circuits with x0 fuse terminal blocks compliant with IEC 607-7-3 standard (fuse not supplied with

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral Technical Datasheet SNK6047D00 Catalogue Page ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral Simplify your PE.N connection with ZS35-PE block connected to ZS35-BL through a premounted jumper. SNK6063F004

More information

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses Technical Datasheet SNK6D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For 5 x 0 and 5 x 5 fuses Protect your circuit with 5x5 and 5x0 fuse terminal blocks, compliant with IEC 607-7-3 standard (fuse

More information

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets Technical Datasheet SNK603D00 Catalogue Page SNK6038S00 ZK.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets The flexible solution for fitting the component of your choice in series

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet 1SNK166D001 Catalogue Page ZS-SF1-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied with

More information

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections Technical Datasheet SNK663D00 Catalogue Page SNK667S00 ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections - Recommended for energy markets and highly demanding applications requiring that

More information

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS50-PE Screw Clamp Terminal Blocks Ground Technical Datasheet SNK607D00 Catalogue Page ZS0-PE Screw Clamp Terminal Blocks Ground - Reliable electrical and mechanical contact with the rail that exceeds the requirements of the IEC 60947-7- terminal

More information

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever Technical Datasheet SNK6D0 Catalogue Page ZS-S-R2 Screw Clamp Terminal Blocks Disconnect with lever Simplify the disconnect operations for the disconnect terminal blocks installed next to fuse terminal

More information

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS35 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK609D00 Catalogue Page ZS3 Screw Clamp Terminal Blocks Feed-through Closed terminal block: - No end section needed, - Optimized rigidity, - Perfectly adapted to solar applications:

More information

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator Technical Datasheet SNK605D00 Catalogue Page SNK60S00 ZK.5-SF-R PI-Spring Terminal Blocks For 5x0 fuses - with blown fuse indicator - Protect your circuits with 5x0 fuse terminal blocks compliant with

More information

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS10-PE Screw Clamp Terminal Blocks Ground Technical Datasheet SNK606D00 Catalogue Page ZS0-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail

More information

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit Technical Datasheet SNK6040D00 Catalogue Page SNK604S00 ZK.-D-PE PI-Spring Terminal Blocks Double deck with ground circuit Improve the safety of your installation in the event of a short-circuit thanks

More information

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS6 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK6008D00 Catalogue Page ZS6 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 6 mm² (without insulated ferrule, CB certified) 0 AWG in just 6 mm 0.36

More information

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link Technical Datasheet SNK656D0 Catalogue Page ZS-ST Screw Clamp Terminal Blocks Test disconnect with sliding link - Secure your disconnect operations in control circuits with the robust sliding link operated

More information

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits Technical Datasheet 1SNK1107D001 Catalogue Page 1SNK1107S001 ZS4-T Screw Clamp Terminal Blocks Triple deck with feed-through circuits Save space: independent circuits in just. mm 0.0 in spacing, - Fit

More information

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS4-PE Screw Clamp Terminal Blocks Ground Technical Datasheet SNK600D00 Catalogue Page ZS4-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail

More information

ZK4-PE PI-Spring Terminal Blocks Ground

ZK4-PE PI-Spring Terminal Blocks Ground Technical Datasheet SNK60D00 Catalogue Page SNK60S00 ZK-PE PI-Spring Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact:

More information

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections Technical Datasheet SNK60D00 Catalogue Page SNK605S00 ZK.5-P PI-Spring Terminal Blocks Feed-through with connections Find all the features of the ZK.5 terminal block with the added option of distributing

More information

ZK6 PI-Spring Terminal Blocks Feed-through

ZK6 PI-Spring Terminal Blocks Feed-through Technical Datasheet SNK69D0 Catalogue Page SNK69S0 ZK6 PI-Spring Terminal Blocks Feed-through Combine high performance with compact dimensions: - 000 V AC / DC IEC 600 V UL, - Opt for the best marking

More information

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections Technical Datasheet 1SNK166D01 Catalogue Page 1SNK166S01 ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections - High density wiring (one potential distribution on 4 independent screw clamps)

More information

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK6D00 Catalogue Page SNK6S00 ZS4-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections Technical Datasheet 1SNK167D01 Catalogue Page 1SNK16S01 ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections Find all the features of the ZK4 terminal block with the added option of distributing

More information

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket Technical Datasheet 1SNK1659D01 Catalogue Page 1SNK160S01 ZK2.5-SP-P PI-Spring Terminal Blocks Disconnect with plug - with test socket The flexible solution for fitting the component of your choice in

More information

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS4 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK60D0 Catalogue Page SNK60S0 ZS4 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 4 mm² (CB certified) AWG in just. mm 0. in spacing. SNK60F00 SNK0000F0000

More information

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse

More information

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections Technical Datasheet 1SNK161D01 Catalogue Page 1SNK165S01 ZK.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections Find all the features of the ZK.5 terminal block with the added option of distributing

More information

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS4-PE Screw Clamp Terminal Blocks Ground Technical Datasheet SNK60D0 Catalogue Page SNK60S0 ZS4-PE Screw Clamp Terminal Blocks Ground Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact:

More information

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections Technical Datasheet 1SNK16D01 Catalogue Page 1SNK1641S01 ZK.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections Improve the safety of your installation in the event of a short-circuit thanks to

More information

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS10 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK6004D00 Catalogue Page SNK6004S00 ZS0 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 0 mm² (CB certified) 6 AWG in just 8 mm 0. in spacing. SNK6008F004

More information

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS6 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK608D0 Catalogue Page SNK608S0 ZS6 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 6 mm² (CB certified) AWG in just 6 mm 0.6 in spacing. SNK6F004

More information

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse

More information

ZDP Pluggable Terminal Blocks Feed-through

ZDP Pluggable Terminal Blocks Feed-through Technical Datasheet 1SNK161D01 Catalogue Page 1SNK161S01 ZDP.- Pluggable Terminal Blocks Feed-through - Save in flexibility, reliability and simplicity thanks to the pluggable terminal blocks ZDP, - They

More information

ZP2.5-PE Spring Terminal Block Ground

ZP2.5-PE Spring Terminal Block Ground Technical Datasheet 1SNK162002D0201.indd 08/06/11 ZP2.5-PE Spring Terminal Block Ground Catalogue Page Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail

More information

DBL distribution blocks 3x1 pole

DBL distribution blocks 3x1 pole TECHNICAL DATASHEET 1SNC166019D0201 - CATALOGUE PAGE 1SNC166020S0201 DBL distribution blocks 3x1 pole 84.6 3.33" 25 0.98" 32.5 1.28" 28.2 1.11" 23.5 0.93" 14.7 0.58" 36.3 1.43" 75 2.95" 62 2.44" 50.7 2"

More information

ZP2.5-4P Spring Terminal Block Feed-through

ZP2.5-4P Spring Terminal Block Feed-through Technical Datasheet 1SNK162005D0201.indd 08/06/11 ZP2.5-4P Spring Terminal Block Feed-through Catalogue Page Thanks to the ZP2.5-4P, PI-Spring terminal block: Save time and connect directly rigid and flexible

More information

ZS4-SF1 Screw Clamp Terminal Block

ZS4-SF1 Screw Clamp Terminal Block Technical Datasheet 1SNK 161 011 D0201 ZS4-SF1 Screw Clamp Terminal Block Fuse Catalogue Page 1SNK 161 011 S0201 4 mm² 10 AWG 8 mm 0.315 in Spacing Features and Benefits 90 90 180 59.7 2.35" - Protect

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions Main catalogue SNK Series Terminal Blocks Accessories Marking Solutions Summary See page 7 1SNK161026S0201 SNK Series, Terminal Blocks Screw clamp terminal blocks Accessories Marking solutions 1 A Smart

More information

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

Main catalog. SNK series Terminal blocks. Phone: Fax: Web:  - Main catalog SNK series Terminal blocks SNK series, terminal blocks, accessories, marking solutions Ranges and technologies presentation 2 1 PI-Spring terminal blocks 1 2 Screw clamp terminal blocks 49

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

Mini contactors B6, BC6 with 3 pole

Mini contactors B6, BC6 with 3 pole Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Surge arrester POLIM-H..SD

Surge arrester POLIM-H..SD Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - BNQ BNQD5T BNQD5 with Front Mounting Clips na.noark-electric.com NOARK Ex9 Series - BNQ Features The BNQ is compliant with UL/CSA/IEC standards

More information

ABB i-bus KNX DG/S x DALI-Gateway Basic

ABB i-bus KNX DG/S x DALI-Gateway Basic ABB i-bus KNX DG/S x.64.1.1 DALI-Gateway Basic The lamps are variably controlled via KNX per DALI output via Broadcast (all lamps jointly) 16 lighting groups 64 individual lamps 16 scenes 64 self-contained

More information

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Brochure. Motor protection and control DRAS enclosed direct-on-line starters Brochure Motor protection and control DRS enclosed direct-on-line starters DRS09 DRS16 enclosed direct-on-line starters 4 to 7.5 kw, protected by thermal overload relays C or DC operated DRS + T16 to

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Surge arrester POLIM-C.. HD

Surge arrester POLIM-C.. HD DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Surge arrester POLIM-H.. ND

Surge arrester POLIM-H.. ND DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

Viking 3 - Screw connection Disconnect terminal blocks

Viking 3 - Screw connection Disconnect terminal blocks 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Viking 3 - Screw connection 1. General features... 1 2. Range...2 3. Standards... 2 4. Technical features... 3 5. Dimensions...

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,

More information