Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Size: px
Start display at page:

Download "Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4"

Transcription

1 Busbar support BBS-/1 BBS-/ , , , BBS-/4 563

2 98, , ,5 6, ,5 12 BBS-/3-16 (25) S-BBS-/ L-BBS-/3 L-BBS-/4 BBC-/ BBC-/ , , , ,5 BBC-1/20, BBC-1/30 BBC-1/20 BBC-1/ Busbar Type 20x5 / 20x10 30x5 / 30x10 564

3 CM-/250/3 CM-/250/4 CM-/250/3/120-5/10 565

4 CM-/630/3 d b CT-5/16 CT-5/35 CT-5/50 CT-5/70 CT-5/120 CT-5/185 CT-5/185 CT-10/35 CT-10/50 CT-10/70 CT-10/120 CT-10/185 d (Busbar thickness) ,5 26,5 26, ,5 26,5 26, a b c 26,5 31, , , , , ,5 a c CT- C B C D D B PT-30/34x10 566

5 BBCH-/ t= BC-20x5-30x10 Technical data (in accordance with EN 269-1, EN ) Technical Specifications PTV-B 00 3p PTV-B 1 3p PTV-B 2 3p Electrical characteristics Rated operating voltage Ue V 690 C 690 C 690 C Rated operating current Ie Conv. thermal current with fuse links Ith Conv. thermal current with solid links Ith Rated frequency Hz Fuse links Size in according to DIN Max. rated current (gl/gg) Max permissible power dissipation (without fuse) Busbar spacing (only 3-pole) Cable connection Flat terminal Bolt diameter Cable lug (DIN 46235) Flat bar Tightening torque Clamp Clamping range Tightening torque Clamp Clamping range Tightening torque Clamp Clamping range Tightening torque Clamp Clamping range Tightening torque Degree of protection - Frontside - Operating state Operating conditions mbient temperature 1) Delovno stanje Vgradni položaj ltitude Pollution degree Overvoltage categorie 1) 35 C Normal temperature, 55 C with reduced current In Pv W mm 40/50/ M8 M10 M10 mm² 1 x (max. 25mm width) mm 20 x x 10 30x10 Ma Nm mm² S00 1,5-70 S1 S Ma Nm mm² P P P Ma Nm mm² F57 1,5-70 P12 2 x P22 1,5-70 Ma Nm x mm² K2G K2G Ma Nm IP00 Tu C Uninterrupted duty Vertical, horizontal m < III 567

6 PRS 00 B TOP 195 PRS 00 B TOP , , ,5 91,5 PTV-B 00 3p M8 PRS 00 B BOTTOM 195 PRS 00 B BOTTOM 230 connection BOTTOM, screw M10 PTV-B 1 3p M10 BOTTOM, PTV-B 2 3p M10 BOTTOM B C D E F G HVL-B 1 3p M10 BOTTOM HVL-B 2 3p M10 BOTTOM

7 connection TOP, screw M10 PTV-B 1 3p M10 TOP, PTV-B 2 3p M10 TOP B C D E F G HVL-B 1 3p M10 TOP HVL-B 2 3p M10 TOP Technical data (in accordance with EN 269-1, EN ) Technical Specifications HVL-B 000 3p F57 Slim Electrical characteristics For NH fuse-links acc. to DIN VDE Size 0 Rated operational voltage Rated operational current 1) Conv. free air thermal current with fuse-links 1) Conv. free air thermal current with solid-links 1) Rated frequency Rated insulation voltage Total power loss at Ith (without fuse-links) Rated impulse withstand voltage Utilization category Rated conditional short-circuit current 2) Rated short-time withstand current Max. permis. power loss per fuse-link Cable terminal Clamp Clamping cross-section Tightening torque Degree of protection Front side Operating condition Switching element open Operating conditions mbient temperature 3) Delovno stanje ctuation Vgradni položaj ltitude Verschmutzungsgrad/Pollution degree Überspannungskategorie/Overvoltage category Ue V 500 C, 220 DC Ie А 125 Ith А 125 Ith А 1 Hz 40- Ui V 500 C Pv W 18 Uimp kv 8 C-22B (500V/125) DC-22B (220V/100) k 50 Icw k Pa W 8 mm² F50 : 1,5-50 Cu / : 6 x 9 x 0,8 Nm 26 IP20 IP10 T C Uninterrupted duty Dependent manual operation Vertical, horizontal m < III 1) In case of mounting of several units in low voltage switchgear-combinations, please consider rated diversity factors acc. to EN ) Type tested with NH-fuse-links characteristic gg 3) 35 C Normal temperature, at 55 C with reduced operating current 569

8 Technical data (in accordance with IEC/EN and VDE 06, part 107) Technical Specifications HVL-B 00 HVL-B 1 Technical Characteristics Rated operational voltage U e V 500 C 690 C 220 DC 440 DC 500 C 690 C 220 DC 440 DC Rated operational current I e Rated frequency - Hz Rated insulation voltage U i V 750 C 750 C Total power loss (without fuse) Pv W 6,9 2,7 6,2 2,7 12,9 8,3 8,6 5,5 Utilisation category - - C22B C22B DC22B DC21B C22B C22B DC22B DC21B Fuse links Size - DIN Max. rated current (gg) I n Max. permissible power lose per fuse link P v W Screw - - M8 M10 Torque Ma Nm V-clip - mm 2 1, Torque Ma Nm 2,6 9,5 Protection Front cover close - - IP20 IP20 Front cover open - - IP10 IP10 Operating condition mbient temperature T u O C -25 to to +55 Operating condition - - Continuous operation Mounting - - vertical, horizontal ltitude - m 2000 Pollution degree Overvoltage category - - III III Technical data (in accordance with IEC/EN and VDE 06, part 107) Technical Specifications HVL-B 2 HVL-B 3 Technical Characteristics Rated operational voltage U e V 500 C 690 C 220 DC 440 DC 500 C 690 C 220 DC 440 DC Rated operational current I e Rated frequency - Hz Rated insulation voltage U i V 750 C 750 C Total power loss (without fuse) Pv W 27 16, ,2 52,8 34,6 21,8 Utilisation category - - C22B C22B DC22B DC21B C22B C22B DC22B DC21B Fuse links Size - DIN Max. rated current (gg/gl) Max. permissible power lose per fuse link Screw Torque V-clip Torque Protection Front cover close Front cover open Operating condition mbient temperature Operating condition Mounting ltitude Pollution degree Overvoltage category I n P v W M10 M10 Ma Nm mm Ma Nm IP20 IP IP10 IP10 T u O C -25 to to Continuous operation - - vertical, horizontal - m III III 570

9 HVL-B 000 3p F PRS 00 B TOP PRS 00 B TOP 230 U S S 106, T PRS 00 B BOTTOM EFM HVL HVL-B 00 3p M8 S T U PRS 00 B BOTTOM ,5 HVL-B 00 3p M8 HVL-B 00 3p F57 571

10 HVL-B 1,2 TOP HVL-B 1,2 BOTTOM TOP J H L1 L E J E L1 L K K max.10 D EFM HVL00 max.10 BOTTOM H D EFM HVL00 G G C B B max.30 F F HVL-B 1 3p M10 HVL-B 2 3p M10 HVL-B 1 3p M10 TOP, HVL-B 1 3p M10 BOTTOM HVL-B 2 3p M10 TOP, HVL-B 2 3p M10 BOTTOM TOP max BOTTOM HVL-B 3 3p M10 TOP, HVL-B 3 3p M10 BOTTOM 572

11 Terminal type Type Tightening torque Clamping range Size flat strip Cable lugs acc. to Screw terminal M8 DIN and F-M8x Nm Clip terminal S00 2,6 Nm 1,5-70 mm² Cu Busbars max. 9x8 flexible flat strip max. 6x9x0,8 Prism clamp P0070 2,6 Nm mm² l/cu Elevator terminal F57 2,6 Nm 1,5-70 mm² Cu max. 1 1 max. 2 0mm Technical data (in accordance with IEC/EN 947-3, VDE 0636 part 301) Technical Specifications DVL-/183 Electrical characteristics Rated operating voltage U e V 400 C Rated operating current I e 63 Conv. Thermal current with fuse links I th 63 Rated frequency Hz 40- Rated insulating voltage U i V 400 C Rated conditional short-circuit current k eff 50 Utilisation category C-23B Rated making capacity 630 Rated breaking capacity 630 Rated impulse voltage U imp kv 8 Electrical lifetime (switching cycles) 300 Total power dissipation (without fuse) P v W 8 Fuselinks Size in according to DIN 49522, D01, D02 Max. rated current (gl/gg) I n 63 Max. permissible power dissipation (without fuse) P v W 55 Mehanical parameters Mechanical lifetime (switching cycles) 1700 Busbar spacing (only 3-pole) mm Busbar thickness mm 5 & 10 Busbar width mm 20 & 30 Cable terminal Terminal, clamping range" mm² 0,75-25 Degree of protection Frontside, operating state IP20 Front cover open IP10 Operating conditions Umgebungstemperatur 1)/mbient temperature 1) Bemessungsbetriebsar t/delovno stanje Einbaulage/Vgradni položaj Höhenlage/ltitude Verschmutzungsgrad/Pollution degree Überspannungskategorie/Overvoltage categorie 1) 35 C Normal temperature, 55 C with reduced current Tu C Uninterrupted duty Vertical, horizontal m < III 573

12 DVL-/ B 35 B PTV-B D02-27/ PTV-B DII-45/ PTV-B DIII-54/ PTV-B D 574

13 B C-PTV-B D02-27/183 C-PTV-B D02-36/183/195 C-PTV-B DII-45/273/195 C-PTV-B DIII-54/333/ ,5 6 0 C-PTV-B D02-27/183/230 C-PTV-B D02-36/183/230 C-PTV-B DII-45/273/230 C-PTV-B DIII-54/333/230 B C ,5 13,5 22,5 27 C-PTV-B D 195 C 6,5 C-PTV-B D 230 Technical data of strip-type D-fuse bases (in according to IEC/EN 269-1, VDE 0636 part 301) Technical Specifications PTV-B D02 PTV-B DII PTV-B DIII Electrical characteristics Rated operating voltage U e V C400 C500 C690 Rated operating current I e Thermal current with fuse links I th Rated frequency Hz Rated insulating voltage U i V C400 C500 C690 Rated conditional short-circuit current ke Fuselinks Size in according to DIN 49522, D02 DII DIII Max. rated current (gl/gg) I n Max. permissible power dissipation (without fuse) P v W 5,5 4 7 Mehanical parameters Busbar spacing (only 3-pole) mm Busbar thickness mm 5 & 10 5 & 10 5 & 10 Busbar width mm 12, 20, 30 12, 20, 30 12, 20, 30 Cable terminal Terminal, clamping range" mm² 0, , ,75-25 Degree of protection Frontside, operating state IP20 IP20 IP20 Operating conditions Umgebungstemperatur 1)/mbient temperature 1) Bemessungsbetriebsar t/delovno stanje Einbaulage/Vgradni položaj Höhenlage/ltitude Verschmutzungsgrad/Pollution degree Überspannungskategorie/Overvoltage categorie 1) 35 C Normal temperature, 55 C with reduced current Tu C Uninterrupted duty Vertical, horizontal m < III 575

14 CL-PTV-B D/230 1, ,5 34, RPH CL-PTV-B D/195 9, RTP-D02-27/183 RTP-D02-36/183 RTP-DII-45/273 RTP-DIII-54/333 RTP-RL/ RTP-D02-27/183 RTP-D02-36/183 RTP-DII-45/273 RTP-DIII-54/ PRS-D /

15 RTP-RL/230 PRS-DVL G-/25/45 45 G-// G-//54 54 G-//63 63 G-//72 72 G-//81 81 G-/63/ G-/63/54 54 G-/63/63 63 G-/63/72 72 G-/63/81 81 D-/25/, D-//, D-/63/ 577

16 578

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fusecarriers enable opening and closing operation in electric

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

LV HRC fuse switch-disconnectors

LV HRC fuse switch-disconnectors The 9 series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole,

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

Vertical fuse disconnects

Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under

More information

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N W SCHRACK-INFO Typ A (pulse) Connection on both sides are possible Tripping independent of line voltage Additional connection capability

More information

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for

More information

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE W SCHRACK-INFO Combined RCD/MCB device Type-A: Protects against special forms of residual pulsating DC which have not been smoothed Line voltage-independent

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

MULTIVERT 250A Size 1, 690VAC

MULTIVERT 250A Size 1, 690VAC MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.

More information

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC FUSE RAILS IEC NH FUSE RAILS FEATURES & BENEFITS Installation on to Dimensions of s and cable connections are equivalent to those of MULTIVERT APPLICATIONS

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Multimeter fuses Metering Fuses Telecom fuses NH 80V Fuses for DC voltage applications NH am 00V a.c. NH gg 0V a.c. Safe work fuses SWF Fuses for protection of forklift batteries

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks Product family fuse-bases Size 00-4a fusebases are suitable for surface mounting on mounting plates and for direct mounting on busbars. In addition, they serve as bases for fuselinks in accordance with

More information

LINOCUR Size D02 63A 230VAC/440VAC

LINOCUR Size D02 63A 230VAC/440VAC IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Filters and Fans Fuse Switch Disconnectors XNH Thermostats Terminals Catalogue 2017 Electrical Cabinet Heating Fuse

More information

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems The Complete Range Easy mounting onto supporting rails Protection against accidental contact in the standart version Perforated versions for connections Drawing of the NH Fuse-Switch, 3-pole switching,

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

MANUALLY OPERATED CHANGEOVER SWITCHES

MANUALLY OPERATED CHANGEOVER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL GREEN PROTECT DC - distribution and protection components Cylindrical fuse-links Fuse holders for cylindrical fuse-links Accessories for cylindrical fuses NH fuse -links NH fuse bases NH fuse disconnectors

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

INNOZED D0 fuse-bases with touch protection

INNOZED D0 fuse-bases with touch protection INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks,

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Utilisation category gl/gg 500VAC with combi indicator

Utilisation category gl/gg 500VAC with combi indicator DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions

More information

FUSE, BUSBAR SYSTEMS TOP-TECHNIC W NEOZED D0 FUSE BASES, SERIES SCHRACK W FUSE DISCONNECTOR FOR PHOTOVOLTAIC PROTECTION W NEOZED FUSE BASE, SERIES WR

FUSE, BUSBAR SYSTEMS TOP-TECHNIC W NEOZED D0 FUSE BASES, SERIES SCHRACK W FUSE DISCONNECTOR FOR PHOTOVOLTAIC PROTECTION W NEOZED FUSE BASE, SERIES WR FUSE, BUSBAR SYSTEMS TOP-TECHNIC 282 W FUSE DISCONNECTOR FOR PHOTOVOLTAIC PROTECTION W NEOZED D0 FUSE BASES, SERIES SCHRACK W NEOZED FUSE BASE, SERIES WR W TYTAN TH1 AND HR12 MAIN PROTECTION W TYTAN-II

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Cam Switch. Rish Cam 16A Rish Cam 32A Rish Cam 100A. Rish Cam 10A Rish Cam 25A Rish Cam 63A Rish Cam 200A. Rish Cam 6A Rish Cam 20A Rish Cam 40A

Cam Switch. Rish Cam 16A Rish Cam 32A Rish Cam 100A. Rish Cam 10A Rish Cam 25A Rish Cam 63A Rish Cam 200A. Rish Cam 6A Rish Cam 20A Rish Cam 40A Rishabh's New Rish Cam I,C,M &INS rotary cam Switches offer a complete range of cam switches for control, Instrumentation and motor starting applications, maximizing the benefits and optimizing your use

More information

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector Catalogue March 2015 InLine II - ZLBM/ZHBM Fuse Switch Disconnector 2 1SEC312022B0202 ABB Catalogue Contents Introduction 1 Apparatus 2 Accessories 3 Technical Data 4 Cable terminations and cable shrouds

More information

General notes. Operating conditions

General notes. Operating conditions TECHNICAL DATA 8 8 1 General notes Wöhner busbar systems and components are the result of expert development based on many years of experience. They have been exhaustively tested and hold many approvals.

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information