High-Precision Fuel Flow Meters

Size: px
Start display at page:

Download "High-Precision Fuel Flow Meters"

Transcription

1 High-Precision Flow Meters FP/FX/ Series Detectors FM/DF Series Display Units FP Series FX Series Series FP Series: For flow rate in bench tests and actual running tests. FX Series: For high-accuracy performance tests of flow rates starting from near-zero. Series: For continuous of mode fuel consumption, etc. We supply a wide range of high-precision flow meters for advanced automobile development and testing. Select the flow meter that best meets your test purpose needs.

2 High-Precision Flow Meter Series that Support Automobile Energy Conservation Countermeasures The global warming phenomenon is one of several global environmental conservation problems that need to be tackled, and the further reduction of fuel consumption is one of the important issues currently being addressed. At Ono Sokki, we have been manufacturing automobile-related measuring and control instruments for over the past half century. With regard to the of fuel consumption, which is an important factor in automobile applications, we have endeavored to develop and manufacture various types of measuring instruments that meet the needs of our customers, and to further increase accuracy. There are three series of flow detectors, the FP, FX, and Series, and we also provide the FM and DF Series display units to enable you to select the optimum combination for your test purpose needs. Configuration Detector FX series Mass-burette flow detector FX-111/112/113 Measurement module FX-4A* 1 For FX series detector Operation Display unit * 4 Display unit for FP/FX/ series detector Front side FP Series Detectors Volumetric flow Capable of long-term continuous flow rate Capable of on-board FX Series Detectors Gravity flow Capable of performing from zero flow (ultra-wide range) Can perform continuous up to a maximum of 1 g (FX-113) Simple configuration with minimal pressure loss Series Detectors Mass flow Capable of long-term continuous without being affected by temperature or pressure enabled -2 series Mass flow detector -21/22A FP series Volumetric flow detector FP-214S/4135 * 4 For series detector DF-4A* 4 For FP series detector Rear side Up to three modules can be stored.* 3 The rear side varies depending on the combination of modules. A single function type display unit for FP/ series detector. FP/FX/ Series Detectors Measurement Range Comparison Chart *Only one module can be stored. FP-213 FP-213S (*1) FP-224HA (*1) FP-2 FP-225A FP to 45 kg/h (.6 to 6 L/h).225 to 9 kg/h (.3 to 12 L/h) (*2).75 to 18 kg/h (1 to 144 L/h).75 to kg/h (.1 to 2 L/h) FP series Volumetric flow detector FM-21A* 2 * 4 For addition/subtraction of two detectors. The range expands. *FP-214S cannot be used with. FP-214S FX-111 FX to kg/h (.5 to 2 L/h) to 36 kg/h to 9 kg/h FP-213/213S/2 214H/224HA/225A MF series On-board flow detector DF series for on-board FX-113 to 18 kg/h A.2 to 82 kg/h Mass flow rate detection system.23 to kg/h (*3) [kg/h] 1 to 19 kg/h Note: (*1): The values are those converted into mass flow rate at a density of.75 g/cm 3. (*2): applies when the.225 to kg/h (.3 to 2 L/h) range has been selected as an option. (*3): The range is the range given for the mass flow rate detection system on Page 12. MF-32 () Support CE Support CE option Not supported CE *1: Modules for FX series detectors can only be used in the top slot. It cannot be used in combination with other modules. *2: It is for FP/ series detectors. Cannot be used for FX series detectors. (See P.5) *3: It can be combined with the same three modules or other modules. (Up to three units.) Refer to the configuration example for combination. *4: It can support CE by combining some of the FP series detectors with the. 2 3

3 Series Volumetric Flow Detectors Wide range thanks to a flow rate ratio (range ability 1/4 or more) Capable of compensating for errors caused by pulsating or backflow by means of a function for judging the rotation direction High reproducibility and high-speed response result in superb reliability Capable of simultaneous of temperature and pressure during flow rate (FP-224HA/225A/FP-4135) * with FP-4135 is an option. High resistance to the environment. (FP-4135) Detector Specification Measurement parameters Applicable fluids Measurement range Accuracy Minimum resolution Operating range loss Connector Gasoline Light oil Kerosene Standard (*1) petroleum oils Alcohol fuels Biofuel FP-213S.6 to 6 L/h (1 to 1 ml/min) Within ±.5 % of (over the entire range).1 ml/.1 L/h Approx. 2.5 kg Phototransistor LEDs (facing each other) Fixed slit Magnetic coupling (*1): Please consult us for details. (*2):.3 to 2 L/h,.3 to 3 L/h flow rate range can also be provided. Please consult us for details. (*3): If the inlet pressure is lower than the pressure loss and if the outlet is open to the atmosphere, the instantaneous flow rate may be varied. (*4): Please consult us if you require specifications other than those given above. (*5): al joint is available. Please consult us for details. (*6): The operating temperature range of the signal processing part of FP-4135 is to +7 ºC..3 to 12 L/h (*2) (5 to 2 ml/min) to 65 ºC to 65 ºC Approx. 4.5 kg The Detection Principle Signal connector Rotating slit Piston Four pistons are arranged radially in the flow detection unit, and move back and forth repeatedly due to the flow of fluid from the inlet to the outlet. The pistons are rotated by the crankshaft, and their movement is transmitted to the magnetic-coupled rotation detection unit. The rotary encoder mounted on the rotation detection unit generates pulse signals in accordance with the amount of piston movement. FP-213 FP-224HA FP-214S FP-4135 FP-2 FP-225A IN : Rc 1/4 OUT : Rc 1/8 Within ±.9 L/h (from.6 to.18 L/h) Within ±.5 % of (from.18 to 6 L/h) Fluid pressure 98 kpa Fluid to 6 ºC temperature Operating temperature to 6 ºC range.1 kpa or less 8 kpa or less (*3) (excluding filter (at 4 L/h, for pressure loss) gasoline) EH-16A provided as standard Approx. 2. kg to ºC to 98 kpa.5 to 2 L/h.1 to 2 L/h (.8 to 3333 ml/min) (1.7 to 3333 ml/min) -3 to +1 ºC Within ±.2 % of (over the entire range) Pt 1 Ω Class B ±.5 % of F.S..1 ml/.1 L/h.1 ml/.1 L/h.1 ºC 1 kpa (:.1 kpa) Same as the range 98 kpa (*4) 98 kpa 2 kpa or less (*3) (at 6 L/h, for gasoline) Approx. 5. kg to 5 ºC to 6 ºC.1 kpa or less (*3) (excluding filter pressure loss) EH- provided as standard Approx. 9. kg IN : Rc 3/8 OUT: Rc 3/8 See outer dimensions for each (page 14 and ). Pt 1 Ω class A.1 ml/.1 L/h.1 8 MPa -3 to +1 ºC -3 to +1 ºC (*6) 4 kpa or less (*3) (6 L/h, gasoline) is built-in Approx. 2.4 kg (including signal processing part) IN : Rc 1/4 (*5) OUT: Rc 1/4 (*5) 1 to 144 L/h (17 to 24 ml/min) 3.4 MPa (*4) to ºC to 98 kpa Within ±.18 L/h (from 1 to 3.6 L/h) Within ±.5 % of (from 3.6 to 144 L/h) Pt 1 Ω Class B ±.5 % of F.S. 1 ml/1 L/h.1 ºC 1 kpa (:.1 kpa) to 65 ºC to 65 ºC 98 kpa (*4) 7.4 kpa or less (*3) (at 5L/h, for light oil) Provided as standard Approx. 14 kg Approx. kg (including separatelyattached filter) attached filter) (including separately- IN : Rc 1/2 OUT : Rc 1/2 Applicable flow detectors Applicable revolution detectors FP-213/213S FP-224HA FP-2 FP-225A FP-4135 FP-214S MF-32 MP-91 MP-981 LG-92 Measurement Time Interval integration time ( * 1) parameter Integration time ( * 1) and number Revolution Revolution speed of digits Interval average revolution speed ( * 2) Interval integration revolution speed Average revolution speed ( * 3) Integration revolution speed ( * 6 * 7) Measurement Instantaneous time Integration Integration Manual setting method mode Time setting method Voltage output Pulse output Type A // Display Unit Specification Revolution setting method Output specification DF-4A Display digit FP-4135 FP-213S 12P/R FP P/R 12P/R FP-224HA 12P/R FP-214S 144P/R FP-2 12P/R FP-225A 12P/R FP. r/min (max. 7 digits). r/min (max. 7 digits). r/min (max. 7 digits) to 9999 kpa (max. 4 digits).1 to to to to Equipment Configuration Examples. to s (max. 7 digits). to s (max. 7 digits) ±. to ºC (max. 4 digits) to kpa Can be specified within the range of 1 to 1 seconds. (in 1-second increments) 1-second Can be specified to 5ms or 1 s. Integration from start time to stop time, specified in the integration mode. Integration from the start to stop signal specified on the panel or by an external signal (communications or remote box (FM-2)). Integration time/revolutions from the start signal to the specified integration flow rate. Integration time from the start signal to the specified integration flow. Integration flow rate/revolutions from the start signal to the specified integration time. Integration flow from the start signal to the specified integration time. Integration flow rate/time from the start signal to the specified integration revolutions. to 1 V/ to F.S. (F.S. value is Voltage output: to 1 V to 1 V/Low to High (Low and High selectable from 1/2/3/5/1 Range setting: to 6/1/12/2/3 values can be optionally specified.) / (kg/h, L/h).) (unit: L/h and kg/h) Voltage output: to 1 V to 1 V/Low to High (Low and High to 1 V/ to F.S. (F.S. value is Range setting: selectable from 2/5 values can be optionally specified.) selectable from 2/5/98/1 (kpa).) /98/1 kpa (input: to +5 V) Voltage output: to 1 V to 1 V/Low to High (Low and High to 1 V/ to 1 Range setting: selectable from to values can be optionally specified.) 1, -5 to 1 Output items: instantaneous flow rate, pulse output:.1/.1/.1 (ml/p or g/p) and direct reducing valve DF-4A.1 to to to to Type B Output H level: V or more Output L level : +.8 V or less to to Output HIGH level: 4.5 V or more Output LOW level:.4 V or less Types A and B: This is the standard system configuration when one detector is used. Type C: A detector is installed at both the supply and return sides, and the difference is used to measure the fuel consumption. Separate standalone displays can also be used for the supply and return sides. The FM-21A in Type C is an addition/subtraction module for two detectors. (Each type of A, B or C is delineated by. FP indicates a detector.) * There is a description of common specification on P.16. Display item Instantaneous flow Interval integration flow ( * 1) Integration flow ( * 1) Interval average flow ( * 4) Average flow ( * 5) Injection amount Interval average injection amount Average injection amount Back pressure regulator valve Unit ml/s, ml/min, g/s, g/min L/h, kg/h ml, g L, kg ml, g L, kg ml/s, ml/min, g/s, g/min L/h, kg/h ml, g L, kg mm 3 /st, mg/st mm 3 /st, mg/st mm 3 /st, mg/st (*1): Integration value can be displayed up to 7 digits. The position of the decimal point moves to the right or left depending on the number of decimal positions of the value. (*2): Interval average revolution speed = Interval integration revolution / interval time (*3): Average revolution speed = Integration revolution / integration time (*4): Interval average flow = Interval integration flow / interval time (*5): Average flow = Integration flow / integration time (*6): Displayed value of mass flow rate is converted at density / temperature / temperature correction coefficient specified in advance. The conversion by actual density is available when simultaneous with the series continuous mass flow meter is performed. (*7): By selecting the encoder pulse setting to be multiplied by 1 for the display digit, it is possible to increase the number of digits after the decimal point by one digit. (Excluding FP-214S, FP-4135). FP FP DF-4A DF-4A FM-21A Type C 4 5

4 Series On-Board Flow Meters FP Series Flow Detectors FP-213S Small flow rate, low pressure loss type Measurement range :.6 to 6 L/h Range ability : 1/1 Accuracy : within ±.5 % of Low pressure loss (1 Pa or less), ideal for measuring the amount of fuel consumption of motorcycles and heating equipments FP-213 Small flow rate type Measurement range :.6 to 6 L/h Range ability : 1/1 Accuracy : within ±.5 % of (.18 to 6 L/h) On-board Flow Meter This is a small flow rate display for FP series detector and MF series detector. s DF-223 Remote box This is a remote switch for START / STOP / RESET at integration. CT-676 Light Shielding Hood This is designed to protect the body from heat caused by sunlight when mounted on vehicle. 6 FP-2 FP-214S Standard flow rate type Measurement range :.3 to 12 L/h Range ability : 1/4 Accuracy : within ±.2 % of Large flow rate type Measurement range : 1 to 144 L/h Range ability : 1/144 Accuracy : within ±.5 % of (3.6 to 144 L/h) Ideal for measuring the flow rate of engines used in buses, trucks, and other large vehicles, as well as marine engines Low pressure loss & ultra wide range, high accuracy and high resolution type Measurement range :.5 to 2 L/h Accuracy : within ±.2 % of Range ability : 1/4 Low pressure loss (1 Pa or less) FP-224HA FP-225A FP-4135 Standard flow rate, simultaneous of temperature and pressure type Measurement range :.3 to 12 L/h Range ability : 1/4 Accuracy : within ±.2 % of Simultaneous of temperature and pressure Large flow rate, simultaneous of temperature and pressure type Measurement range : 1 to 144 L/h Range ability : 1/144 Accuracy : within ±.5 % of (3.6 to 144 L/h) Simultaneous of temperature and pressure Ideal for measuring the flow rate of engines used in buses, trucks, and other large vehicles, as well as marine engines On-board type Measurement range :.1 to 2 L/h Accuracy : within ±.2 % of Range ability 1/2 Operating temperature : -3 to +1 ºC Corresponding to standard alcohol Specification Applicable detector Display method Display item and Integration flow digit number software Instantaneous flow Integration time Output section Voltage output Instantaneous flow CAN output RS-232C (option) Function section Instantaneous flow average Instantaneous flow analog output Indexation average Backward flow correction temperature correction function (convert into weight) Output calibration (CAL) General specification Conforming standard Factor Power source Current consumption Operating environment Altitude Operating temperature range Storage temperature range Operating humidity range Storage humidity range Safety CE marking FP-4135, FP-213/213S,, FP-224HA, FP-214S, MF-32 Fluorescent display tube mm mm (2-stage display). to When the display value reaches its maximum, change and display the decimal point. The decimal point is variable according to the weight per selected pulse. When the multiplication is ON, add one decimal digit to the above values.. to The decimal point is variable according to the weight per selected pulse. When the multiplication is ON, add one decimal digit to the above values.. to (kpa) ±. to (ºC). to (s) If the number of digits of the value is insufficient, the decimal place is rounded up to display. Voltage output : to 1 V Range setting : to 6/1/12/2/3 (unit: L/h and kg/h) Update period : 1 ms (standard)/1 ms (option) Average indexation settings (Standard): 1 N 1 (initial value N=3) () : 1 N 1 (initial value N=3) Voltage output : to 1 V Range setting : select from to 1, -5 to 1 ºC Update period : 1 ms Average indexation settings 1 N 1 (initial value N=2) Voltage output : to 1 V Range setting : select from 2/5/98/1 kpa (for input: to +5 V) Update period : 1 ms/1 ms (option) Average indexation settings (Standard): 1 N 1 (initial value N=2) () : 1 N 1 (initial value N=2) The number of output pulse :.1/.1/.1 (ml/pulse or g/pulse) and direct Minimum pulse duration : approx. 1 µs, Output item: instantaneous flow Output waveform : square wave duty 5 % High level: +4.5 V or more Low level : +.4 V or less Protocol : conforms to CAN Ver. 2.B Bus data format : Endian: Big Endian (Motorola) ID : 721 (initial value) 1 to x7ff Variable Termination resistor : ON/OFF function Baud rate : 125 kbps/25 kbps/5 kbps/1 Mbps Output update cycle : select from OFF/1 Hz/2 Hz/5 Hz/1 Hz/2 Hz/1 Hz/1 khz (option) Output item : instantaneous flow (L/h)/ temperature (ºC)/pressure (kpa)/integration flow (L) (option)/ integration time (s) (option) Serial communication (asynchronous method): 96 bps/384 bps Displays the data obtained through moving average from.5 to 1 s of the instantaneous flow which is updated and displayed every 5 ms or 1 s. OFF/ON (N=1 to 1) OFF/ON (N=1 to 1) Detect a backward flow and correct the flow amount Correction function to correct the flow amount V_OUT ZERO: V V_OUT FULL : 1 V 1 to 1 Battery connection: 1 to 28 VDC When using AC adapter (option): 1 to 24 VAC 5/6 Hz 28 VA or less (when 12 VDC) Indoor, in a vehicle Elevation 2m or less to +5 ºC *Operating temperature range of AC adapter is to +4 ºC -1 to +6 ºC 5 to 8 % 5 to 85 % 17 (W) 49 (H) 12 (D) Approx. 8g IEC611-1: Over-voltage category Ⅱ Protection Class Ⅱ Pollution level Ⅱ When using an optional AC adapter LVD Directive 214/35/EU Standard EN611-1 (with AC adapter) EMC Directive 214/3/EU Standard EN RoHS Directive 211/65/EU Standard EN5581 DF-221: Auto stop function DF-224: DA/CAN high speed output function (an option to make the output speed higher from 1 ms to 1 ms.) DF-225: CAN integrated value output function 7

5 Series Gravity Flow Detectors High-accuracy flow rate over a wide range Built-in air purging function to counteract the mixing air bubbles Alarm function against overflows and low fluid levels corrections due to changes in the temperature are no longer required. Increased pressure and pressure feed are available as options. Measurement accuracy: within the combined range of ±.2 % of value and ±.1 % of F.S. Detector Specification Solenoid valve for charging (V1) Fluid inlet Fluid outlet FX-111 FX-112 FX-113 Applicable fluids Gasoline, Light oil, Kerosene or Alcohol fuels (option) Measurement range to 1 g/s ( to 36 kg/h) to 25 g/s ( to 9 kg/h) to 5 g/s ( to 18 kg/h) Accuracy (*1) Within the combined range of ±.2 % of value and ±.1 % of F.S. Instantaneous flow resolution.1 g/s.1 g/s Integration flow resolution.1 g.1 g Maximum integration amount (single fill operation) Operating maximum pressure Operating temperature range (*2) Open-atmosphere processing Inlet, outlet, and return joints 2 g R3/8 5 g 196kPa to +4 ºC (with no freezing) Solenoid valve for overflow protection R1/2 1 g Internal : φ6 External : φ9 Hose nipple (for both IN and OUT) Internal : φ12 External : φ16 Hose nipple (for both IN and OUT) Approx. 13 kg See (9) on Page (*1) If the temperature changes rapidly during, the above accuracy cannot be guaranteed. (*2) Vapor may be produced in this temperature range, and may prevent normal. The Detection Principle L1 L2 L3 L4 Air purging Anti-overflow solenoid valve Differential pressure transducer Cover If the fluid level falls below L3, the pressure signal generated by the detector causes the solenoid valve V1 to open and more fluid to flow in. When the fluid level reaches L2, valve V1 closes. Measurement of the flow rate starts after the specified time for the surface of the fluid to reach the fixed level has elapsed. As the fluid level falls from L2 as it is being consumed, the output from the differential pressure transducer changes in accordance with the gravity of the consumed fluid, and the gravity flow rate is obtained from this changed amount. Alarms are generated if the fluid reaches the L1 overflow level or falls to the L4 insufficient fluid level. FX-11 series Applicable flow detectors Applicable revolution detectors Measurement Time parameter and number Revolution of digits ( + FX-4A) FX-111, FX-112 or FX-113 MP-91, MP-981 or LG-92 (*8) (*1) Integration value can be displayed up to 7 digits. The position of the decimal point moves to the right or left depending on the number of decimal positions of the value. (*2) Interval average revolution speed = Interval integration revolution / interval time (*3) Average revolution speed = Integration revolution / integration time (*4) Interval average flow = Interval integration flow / interval time (*5) Average flow = Integration flow / integration time (*6) Displayed value of volumetric flow is the value converted at density / temperature / temperature correction coefficient specified in advance. (*7) Update interval of voltage output:.1 seconds, accuracy: ±.1 %/F.S. (*8) The MP-91 can be connected via the MX-xx series cable, the MP-981 and the LG-92 can be connected via the MX-8 series cable. Display Unit Specification Measurement time (max. 7 digits) (*6) Integration mode Alarm output Voltage output (*7) for fuel charge FX-4A Interval integration time (*1) Integration time (*1) Revolution speed Interval average revolution speed (*2) Interval integration revolution speed Average revolution speed (*3) Integration revolution Applicable detectors Instantaneous flow Interval integration flow (*1) Integration flow (*1) Interval average flow (*4) Average flow (*5) Injection amount Interval average injection amount Average injection amount Instantaneous Integration Manual setting method Time setting method Revolution setting method (no output during charging) Output specification Equipment Configuration Examples FX reducing valve * There is a description of common specification on P.16.. to s (max. 7 digits). r/min (max. 7 digits). r/min (max. 7 digits) FX-111 FX-112 FX-113 Units.. ml/s, g/s. ml/min, g/min.. kg/h. L/h. to to ml, g, L, kg Same as for instantaneous flow.. mm 3 /st, mg/st Can be specified within the range of 1 to 1 seconds (in 1-second increments). Integration from the start time to stop time, specified in the integration mode. Integration from the start to stop signal specified on the panel or by an external signal (communications or remote box (FM-2)). Integration time/revolutions from the start signal to the specified integration flow rate. Integration flow rate/revolutions from the start signal to the specified integration time. Integration flow rate/time from the start signal to the specified integration revolutions. Overflow (L1 level): Monitor display and external contact output Low fluid surface (L4 level): Monitor display and external contact output to 1 V/Low to High (Low, High values can be optionally specified.) FX-111: Selectable from.1/.1 (ml/p, g/p) FX-112: Selectable from.1/.1 (ml/p, g/p) FX-113: Selectable from.1/1 (ml/p, g/p) Frequency range: to 1 khz, Output H level: +2.4 V or more, L level: +.8 V or less See (12) on Page. Power box FX-7B Made to order Air pressure Accumulator Apply pressure Pump 12VDC P FX FX-4A Type A This is the standard system configuration when one detector is used. (When fuel supply pressure is applied.) (This type is delineated by. FX indicates a detector.) * The only one FX-4A module can be installed on the. Increased pressure type: An accumulator is used to enable an increase in pressure. Use this method when fuel cannot be supplied due to reasons such as not being able to install the detector in a high position. (The FX-7B power box is an option.) 8 9

6 Series Mass Flow Detectors Continuous without being affected by temperature, pressure, and density High accuracy (up to range ability 1/4 within ±.1 % of accuracy) enabled The case for purging internal air is provided to each detector. The fluid that entered from the inlet passes through the tube and goes out through the outlet. With this flow meter, the application of its inherent vibration to the tube causes a movement equivalent to the angular velocity, thereby generating a Coriolis force. As shown in the figures above, since the tube with Coriolis force generates a twist proportional to the mass flow rate, the mass flow rate is calculated from the amount of this twist. Detector Specification A Measurement parameters Applicable fluids (*1) Measurement Normal mass flow rate range Normal volumetric flow rate Maximum flow rate (*2) Accuracy of at.2 to 2 kg/h reproducibility temperature characteristic loss (when measuring gasoline) Approx. 1 kpa at 82 kg/h Withstand pressure Operating temperature range (*2) Approx. 12 kg (*1): Can also be used with CNG and LPG gases (option). Please consult us for details. (*2): Please consult us for temperatures and densities that exceed the above ranges. -21 Detector The Detection Principle Drive coil Right pickoff coil Left pickoff coil Tube vibration Fe=2 MωV M: Mass of the moving body ω: Angular velocity V: Velocity at which the mass moves Force against the tube from the fluid on the inlet side,, and Gasoline, Light oil, Kerosene, Water, Standard petroleum oils, or Alcohol fuels (option).2 to 82 kg/h 1 to 19 kg/h.27 to 19 L/h at.75 g/cm to 1453 L/h at.75 g/cm 3 18 kg/h 218 kg/h to 1 g/cm 3 ±.1 % of at 2 to 82 kg/h ±.1 % of at 27 to 19 kg/h ±(.2 kg/h/flow rate) within 1 % ±(.27 kg/h/flow rate) within 1 % of at 1 to 27 kg/h ±.5 g/cm 3 ±.2 g/cm 3 ±. g/cm 3 /ºC Approx. 1 kpa at 19 kg/h 1 MPa to +4 ºC Approx. 9 kg See (1) on Page See (11) on Page Inlet Axis of twist Inlet side Example of actual fuel mass flow rate data at the North American transient test mode Outlet side Support side Outlet side Force against the tube from the fluid on the outlet side / Display Unit Specification Applicable flow detectors Applicable revolution detectors Measurement Time parameter and number Revolution of digits Measurement time Integration mode Voltage output (*6) (max. 7 digits) Interval integration time (*1) Integration time (*1) Revolution speed Interval average revolution speed (*2) Interval integration revolution Average revolution speed (*3) Integration revolution Applicable detectors Instantaneous flow Interval integration flow (*1) Integration flow (*1) Interval average flow (*4) Average flow (*5) Injection amount Interval average injection amount Average injection amount Converted temperature setting Instantaneous Integration (flow/time) Manual setting method Time setting method Revolution setting method * There is a description of common specification on P.16. ( + ) ( + ) -21 or -22A MP-91, MP-981 or LG-92 (*7).r/min (max. 7 digits).r/min (max. 7 digits). to s (max. 7 digits) ±. to ºC (max. 4 digits) A Units A Units.. ml/s, ml/min, L/h, g/s, g/min, kg/h.. L/h, kg/h. to to ml, g, L, kg Same as for instantaneous flow rate Same as for instantaneous flow rate.. mm 3 /st, mg/st. to ºC (density calculation performed for the three specified temperature points) Can be specified within the range of 1 to 1 seconds. (in 1-second increments). g/cm 3 (5 digits) Integration from start to stop, specified in the integration mode. Integration from start to stop signal specified on the panel or by an external signal (communications or remote box (FM-2)). Integration time/revolutions from the start signal to the specified integration flow rate. Integration flow rate/revolutions from the start signal to the specified integration time. Integration flow rate/time from the start signal to the specified integration revolutions. to 1 V / Low to High (Low and High values can be optionally specified.). to to ml, g to 1 V/ to 1-21: Selectable from.1/.1 (ml/p, g/p) -22: Selectable from.1/1 (ml/p, g/p) Output specification Frequency range: to 1 khz, Output H level: +2.4 V or more, L level: +.8 V or less See (12) on Page See (13) on Page (*1) Integration value can be displayed up to 7 digits. The position of the decimal point moves to the right or left depending on the number of decimal positions of the value. (*2) Interval average revolution speed = Interval integration revolution / interval time (*3) Average revolution speed = Integration revolution / interval time (*4) Interval average flow = Interval integration flow / interval time (*5) Average flow = Integration flow / integration time (*6) Update interval of voltage output:.1 seconds, accuracy: ±.1 %/F.S. (*7) The MP-91 can be connected via the MX-xx series cable, the MP-981 and the LG-92 can be connected via the MX-8 series cable.. to ºC (density calculation performed for the one specified temperature point) 1-second Integration time from the start signal to the specified integration flow rate. Integration flow rate from the start signal to the specified integration time. to 1 V / to F.S. (F.S. value is selectable from 1/2/3/5/1/ (kg/h, L/h)) to 1V / to 1 g/cm 3 flow rate (kg/h) flow rate shaft torque revolutions revolutions (r/min) shaft torque (N m) Equipment Configuration Examples reducing valve Back pressure regulator valve Time (s) Type A Type B FM-21A Type C Types A and B: This is the standard system configuration when one detector is used. Type C: A detector is installed at both the supply and return sides, and the difference is used to measure the fuel consumption. (Please consult us when considering purchasing this type.) The FM-21A in Type C is an addition/subtraction module for two detectors. (Each type of A,B or C is delineated by. indicates a detector.) 1 11

7 12 Mass Flow Rate Measurement Systems (Applications) This system uses two detectors, the volumetric flow detector and the -22A mass flow detector. Volumetric flow rate values are converted with high accuracy using density values and displayed as mass values. Continuous without being affected by temperature, pressure or density Wide range (up to range ability 1/1 within ±.35 % of accuracy) enabled A function for removing air bubbles to enable the supply of bubble-free fuel is provided. A mechanism purging initial air at the time of workpiece replacement is provided. Measurement parameters Applicable fluids Measurement Normal mass flow rate range Normal volumetric flow rate Maximum flow rate (*1) Accuracy accuracy reproducibility temperature characteristic loss Operating temperature range (*1) Specification,, and Gasoline, Light oil, Kerosene, Standard petroleum oils or Alcohol fuels (option).23 to kg/h at.75 g/cm 3.3 to 2 L/h 225 kg/h (3 L/h at.75 g/cm 3 ) to 1 g/cm 3 Within ±.35 % of at.3 to 2 L/h ±.5 g/cm 3 ±.2 g/cm 3 ±. g/cm 3 /ºC to +4 ºC Approx. 2 kg (including a solenoid valve controller) (*1) Please consult us for temperature and densities that exceed the above ranges. This system uses the -21 mass flow detector for high-accuracy detection of the mass of an LPG flow rate. Mass Flow Rate Detection System LPG Mass Flow Rate Detection System Measurement parameters Measurement Mass flow rate range (*1) Accuracy loss Operating temperature range (*1) Specification,, and.2 to 6 kg/h to 1. g/cm 3-2 to +55 ºC ±.1 % of at 2 to 6 kg/h ±(.2 kg/h/flow rate) 1 % of at 2 kg/h or less ±.5 g/cm 3 ± 1 ºC ±.5 value ºC Approx. 1 kpa at 82 kg/h to +4 ºC Approx. 2 kg (*1) Please consult us for temperature and density that exceed the above ranges. Mass Flow Rate Detection System (delineated by ) Type E reducing valve DF-4A FP LPG Mass Flow Rate Detection System (delineated by ) LPG Heat exchanger Cooling water circulator Flow Meter Peripheral Devices Settable pressure range Withstand pressure Operating temperature range Connector fitting Body material MF-32 Automotive Flow Detector (using ) MF-32 flow detection system is an in-vehicle type detection system using for the detecting section. flow rate is measured by combination with FM series and DF series flow indicator. Used for only diesel engines (other than in- fuel pump cars). * Please contact us separately for other than diesel engine. High accuracy within ±.2 % ( value) Reduction in size and weight by blocking each component cooling function is provided as standard equipment. and pressure can be measured simultaneously with flow rate. Configuration Specifications Drain * Normally closed by a plug. From Tank To Tank DC12 V Tank P Pump DF/FM series counter Volumetric flow detector Relief valve EH-49 Regulator Valve / EH-59 Relief Valve For models with standard specification For models that can detect alcohol fuels Remote Box Press1 sensor sensor -1 to 1 kpa T P reducing valve Simple heat exchanger EH-49 EH-59 2 to 7 kpa 5 to 2 kpa Max..8 MPa to +7 ºC Rc1/4 (for both IN and OUT) Aluminum Approx. 5 g Compatible s and Elements Compatible detectors Element Element MF-32 To Returm In EH-16A Provided together with the filter unit * Note: Please contact us for details. EH- 98 kpa withstand pressure, element provided (paper, 5 µm) EH-16A 98 kpa withstand pressure, element provided with the main unit (sintered metal, 5 µm) * Only an element cannot be provided. EH-17A 98 kpa withstand pressure, element provided (stainless steel wire mesh, 5 µm) MF- Automatic Air Purging Tank For FP-213S/213 For /224HA For FP-2/225A Measurement items Used flow rate detector Measurement item Measurement range Measurement accuracy processing Operating temperature range EH- EH- (one set for 5 pieces) EH-17A * (See Note) The MF- is an automatic air purging that uses a precision float valve. When fluid enters the flow line, the air is automatically purged to the atmosphere. Applicable fluids : Gasoline, light oil or kerosene Maximum flow rate : Approx. 1 L/h Tank capacity :.7 L Withstand pressure : 2 kpa Joint : Hose nipple R1/4 Internal : φ6 mm External : φ9 mm (for both IN and OUT) : Approx. 1.8 kg : φ93 (W) 197 (H) mm (not including protruded section) MF-32 MF-32, temperature, pressure Light oil.3 to 12 L/h to 98 kpa to ºC Within ±.2 % of value ±.5 %F.S. Pt1 Ω class B control method (Using the precise pressure reducing valve) to +65 ºC (both liquid and ambient) Approx. kg 26 (W) 243 (H) 243 (D) mm * (See Note) 13

8 Outer Dimensions Unit: mm (1) FP-213S (2) FP-213 FUEL IN (R1/4) FUEL OUT (R1/8) φ7 FUEL OUT (R1/8) (163) 6 to 5.5 Cut FUEL IN (R1/4) 54 (8) FP-4135 (9) FX-11 outlet (Rc 1/4) M6x1 Screw hole depth 1 inlet (Rc 1/4) (93) 55 4-M φ h IN/OUT Hose nipple Type FX mm External φ9 Internal φ6 R3/8 FX mm External φ16 Internal φ12 R1/2 FX-113 9mm External φ16 Internal φ12 R1/2 AIR VENT signal connector 75 (9) 6 (32) 1.5 (13.5) 7 (4) signal connector (φ5) (25) (55) (144) 2 4-M (11) h OUT IN Signal connector 55 (3) (4) FP-224HA Mounting hole Mounting hole 1 6 Directly attached cable 2 m Connection to signal processing part Connection to temperature signal cable (1) -21 (11) -22A M4 Depth 4-M4 Depth 7 FUEL OUT (R3/8) 46 (266) (197) (1) FUEL IN (R3/8) FUEL OUT (R3/8) (327) (258) (1) FUEL IN (R3/8) Mounting hole Mounting hole signal connector 4-M 16 (5) FP-2 (6) FP-225A (7) FP-214S (214) signal connector FUEL IN (R1/2) φ12 hose nipple FUEL OUT (R1/2) φ12 hose nipple signal connector 4 28 signal connector 2-Mounting hole 2 89 FUEL IN (R1/2) φ12 hose nipple M (16) Mounting hole 1 (161) 2 18 (43) (73.5) (53) 74 signal connector signal connector FUEL OUT (R1/2) φ12 hose nipple signal connector 9 97 signal connector *1: Do not fix with both sides (rear and bottom) to avoid distortion so that the result will be not affected. OUT (12) IN 38.5 SIG (6) 36 (1) *4 (46) *42 (48) (13) (14) Panel mounting fixture UA () 99±.8 18 Panel mounting fixture UA-2 (6) (34) 23 (54) IN Rc1/2 (4.2) 31 (12) Panel cutout dimensions OUT Rc1/2 4-M5 5±.5 (3) SIG 235 (1) (35) (26) Note 1: The dimensions with the * mark: for the panel cutout dimensions. The values within the parentheses ( ): for 48 mm rack. Note 2: Panel mounting fixture model names UA-1: For 48 mm rack UA-2: For panel mounting 6 FUEL OUT φ9 φ7 R3/8 Hose nipple (16.5) 13 4-φ6.6 (Unavailable for rear fixing. Only for bottom fixing to use. )* 1 FUEL IN φ9 φ7 R3/8 Hose nipple 21 (7.7) ±.8 () (6) (34) (4.2) 27 (8.7) 8-M3(Including the other side. For option installation.) 48 4-M5 signal connector (55) 22 4± (29.5) (5) 12 (11.3) (1.5) 125 (9.5) (38) (13) 142 (134) 8-φ6.6 (Unavailable for bottom fixing. Only for rear fixing to use.)* 1 Note: Panel mounting fixture model name: UA Panel cutout dimensions 14

9 / Display Unit Common Specification ( * 1) (*2) Display LCD with CFL backlight, 32 x 24 dots Fluorescent display tube (2 characters x 2 lines), 5 8 dots Interface (*3) Remote (*4) Commands START, STOP, HOLD, RESET or DISP Input levels H: +2.4 to V, L: +.8 V or less RS-232C (*5) Communication method: Asynchronous full-duplex mode, data length: 8 bits Baud rate (*6) : 96, 192, 384, 576, 12 bps GPIB (model name: FM-263) Digital input/output (model name: FM-361) Memory Measurement Capacity 3 addresses function memory Capture timing Automaticlly saved when Hold or Stop, automatic increment of addresses from 1 to 3 Memory Memory capacity 1 Mbyte (SRAM) backup Data backup period Approx. 1.5 months (at 25 ºC) Battery: Coin-type vanadium lithium secondary battery General Environmental Storage temperature/ specification condition humidity range -2 to +6 ºC, 1 to 9 % RH (with no condensation) Operating temperature/ humidity range to +4 ºC, 1 to 9 % RH (with no condensation) Approx. 7 kg (When three modules are installed.) Approx. 4.2 kg Power Power requirement 1 to 24 VAC ±1 %, 5/6 Hz requirement Maximum current consumption 4 VA or less External fuse: 2 A 3 VA or less External fuse: 2 A Insulation resistance 1 MΩ or more (5 VDC rated power voltage) Withstand voltage VAC for one minute Compatible shock-resistance standard JIS C 41:1999 (peak acceleration: 3 m/s 2, shock application period: 18 ms) Compatible vibration-resistance standard JIS C 4:1999 (vibration acceleration: 1 m/s 2, vibration frequency range:1 to Hz) Compatible standard IEC/EN611-1: 21 (2nd Edition) / CE marking (*1): Specifications that are common to the and (Pages 5/9/11). Moreover, indicates specifications that are not included with the. (*2): CE marking is available when it is combined with the series and some of the FP series. Please consult us for details. (*3): Only one interface unit can be installed. The RS-232C interface cannot be used if a GPIB interface is installed. (*4): The model name of Remote Box is the FM-2. (*5): With the, the DPU-414 digital printer (option) can be used to print out measured values. (RS-232C interface) (*6): Baud rate of the : 96 bps Product list FP/FX/ series detector Model Specification FP series FP to 6 L/h FP-213S Capable of compensating for pressure errors of FP to 12 L/h.3 to 2 L/h (remodel) FP-224HA + temperature/pressure detector FP-2 1 to 144 L/h FP-225A FP-2 + temperature/pressure detector FP-4135 On-Board volumetric flow detector FP-214S Servo type flow detector FX series FX-111 to 1 g/s ( to 36 kg/h) FX-112 to 25 g/s ( to 9 kg/h) FX-113 to 5 g/s ( to 18 kg/h) series to 82 kg/h -22A 1 to 19 kg/h On-board flow detector Model Specification MF series MF-32 For light oil vehicle series Model Specification DF series On-board flow detector DF-221 Auto-stop function DF-222 RS-232C communication function DF-223 Remote box DF-224 High speed output function DF-225 Output function of CAN integration value PS-P223A AC adapter Battery cable for AC adapter 2m CT-673 Panel mounting fixture CT-675 Protection plate CT-676 Light shielding hood Peripheral for flow detector Model Specification Automatic air purging MF- Tank capacity: approx..7 L FM series display unit and storage modules Model Specification Digital flow meter For FP/FX/ series detector For FP/ series detector Measurement DF-4A Dedicated for FP series detector module FX-4A Dedicated for FX series detector Dedicated for series detector Module for result of FM-21A For FP/ series detector, dedicated for addition/subtraction GP-IB board FM-263 For / DI/DO board FM-361 For Remote box FM-2 For / Signal cable between the FP series detector and display units Signal cable For between detector and display unit Object Model Length Detector model For flow rate FP-11 5 m FP-12 1 m FP-213/213S/214H/224HA/2/225A FP-14 2 m FP- 5 m FP-16 1 m FP-214S/4135 FP-17 2 m For temperature FP-25 5 m FP-26 1 m FP-224HA/225A/4135 FP-27 2 m For pressure FP-35 5 m FP-36 1 m FP-224HA/225A/4135 FP-37 2 m Signal cable for connecting the FX series detector with display units For flow rate FX-21 5 m FX-22 1 m FX-111/112/113 FX-23 2 m FX-4A (Measurement module for storage) Signal cable for connecting the series detector with the display units For flow rate m m -21/22A m (Measurement module for / storage) WORLDWIDE ONO SOKKI CO., LTD Hakusan, Midori-ku, Yokohama, , Japan Phone : Fax : overseas@onosokki.co.jp Outer appearance and specifications are subject to change without prior notice. * URL: U.S.A. Ono Sokki Technology Inc Executive Drive, Suite 4, Addison, IL. 611 U.S.A. Phone : Fax : info@onosokki.net THAILAND Ono Sokki (Thailand) Co., Ltd. 1/293-4 Moo.9 T.Bangphud A.Pakkred, Nonthaburi 1112, Thailand Phone : Fax : sales@onosokki.co.th INDIA Ono Sokki India Private Ltd. Plot No.2, Ground Floor, Sector-3, IMT Manesar Gurgaon-1225, Haryana, INDIA Phone : Fax : osid@onosokki.co.in P.R.CHINA Ono Sokki Shanghai Technology Co., Ltd. Room 56, No.47 Zhengyi Road, Yangpu District, Shanghai, 2433, P.R.C. Phone : Fax : admin@shonosokki.com Recycled Paper CAT.NO.497-5E Printed in Japan 188 (SUN).5K

High-Precision Fuel Flow Meters

High-Precision Fuel Flow Meters High-Precision Fuel Flow Meters FP/FX/FZ Series Detectors FM Series Display Units FP Series FX Series FP Series: For flow rate measurement in bench tests and actual running tests. FX Series: For high-accuracy

More information

Digital Engine Tachometer

Digital Engine Tachometer Digital Engine Tachometer CT-6700 Compact and portable design Compact Tachometer for various engine measurement The CT-6700 is a digital engine tachometer to measure rotation speed of gasoline/diesel engines,

More information

FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD.

FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD. FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD. 1. This document may not be reproduced, in whole or part, in any form or by any means without the prior written permission

More information

FP-2000/200 Series POSITIVE DISPLACEMENT TYPE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD.

FP-2000/200 Series POSITIVE DISPLACEMENT TYPE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD. FP-2000/200 Series POSITIVE DISPLACEMENT TYPE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD. 1. This document may not be reproduced, in whole or part, in any form or by any means without the prior

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type Stepping Motor Driver Package High-Efficiency R Series DC Power-Supply Input Built-in Type Type The extensive R Series DC Power-Supply Input lineup that utilizes high-efficiency technology. Two types are

More information

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors E-Series Model EH Synchronous Serial Interface (SSI) Output Data Sheet SENSORS Document Part Number: 551314 Revision B Model

More information

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target

More information

Stepper Motors ver ver.5

Stepper Motors ver ver.5 A Stepper s Stepper s A-1 Overview... A-2 Overview and... A-15 & Stepper and RK Series A-16 RK... A-47... A-51 Stepper Series A-52 Stepper Series A-8 See Full Product Details Online www.orientalmotor.com

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL

AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL CONSUMPTION MEASUREMENT AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Balance and AVL Fuel Temperature Control is a high precise fuel consumption measurement and conditioning

More information

SRT1000 Series THERMAL FLOWMETER

SRT1000 Series THERMAL FLOWMETER High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

High-Efficiency AR Series. RK Series /0.72 /Geared. CRK Series. RBK Series. CMK Series. 2-Phase Stepping Motors A-278.

High-Efficiency AR Series. RK Series /0.72 /Geared. CRK Series. RBK Series. CMK Series. 2-Phase Stepping Motors A-278. A Stepping Motors Stepping Motors Introduction A-2 Introduction AC Power Supply Input Stepping Motor and Driver Packages A-17 DC Power Supply Input Stepping Motor and Driver Packages Stepping Motors (Motor

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

EZS. Motorized Linear Slides. Series. RoHS-Compliant

EZS. Motorized Linear Slides. Series. RoHS-Compliant RoHS-Compliant Motorized Linear Slides EZS Series AUDIN -, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3...1 - Fax : 3... - Web : http: www.audin.fr - Email : info@audin.fr RoHS-Compliant

More information

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy Instruction Manual Digital Panel Meter Model 3126 I-01861 1. Preface Thank you for purchasing our digital panel meter 3126 series. Before use, read this manual carefully and thoroughly, and keep this manual

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

EM DC Multi-Function DC Energy Meter

EM DC Multi-Function DC Energy Meter Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor

More information

RoHS Directive-Compliant Motorized Linear Slides EZS Series for Clean Room Use. Features

RoHS Directive-Compliant Motorized Linear Slides EZS Series for Clean Room Use. Features Motorized Actuators RoHS Directive-Compliant Series for Clean Room Use The Series for Clean Room Use is a product designed with the same level of function and performance as the Series but is ideal for

More information

Hybrid Control System, Alpha Step

Hybrid Control System, Alpha Step B Hybrid Control System, Alpha Step Hybrid Control System B-1 Overview... B-2 Overview Hybrid Control System Battery-Free, Absolute Sensor Equipped AZ Series... B-16 Electric Linear Slides EZS Series AZ

More information

J1000. Compact Inverter Series.

J1000. Compact Inverter Series. J1000 Compact Inverter Series www.yaskawa.eu.com Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

Analog Input Terminal

Analog Input Terminal Analog Input Terminal I/O Interface Converts Analog Input Data into Binary Data Four inputs available. High resolution of 1/6000. Conversion is possible within a range of 5% to 105% FS. High conversion

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).

More information

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V Sorensen XG Series / XTR Series 670 850 W 850 W, 1U Half Rack Programmable DC Power Supplies 6 600 V Highest Power Density Comprehensive Digital and Analog Interface Options Scalable, Multi-Unit Design

More information

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

NX Series. Tuning-Free AC Servo Motor Unit

NX Series. Tuning-Free AC Servo Motor Unit Tuning-Free AC Servo Motor Unit NX Series An AC servo motor unit that is capable of high accuracy control with easy operation. Smooth operation can be achieved in high inertia loads or belt drive applications

More information

Agilent 7693A Automated Liquid Sampler

Agilent 7693A Automated Liquid Sampler IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7693A Automated Liquid Sampler

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

St epping Mot or s C-i ORIENTAL MOTOR GENERAL CATALOG 2009/2010

St epping Mot or s C-i ORIENTAL MOTOR GENERAL CATALOG 2009/2010 C-i ORIENTAL MOTOR GENERAL CATALOG 29/21 C Introduction C-2 Stepping Motor and Driver Packages AC Input Stepping Motor and Driver Packages DC Input Stepping Motors AC Input AS Series C-14 DC Input ASC

More information

Analog Output Terminal

Analog Output Terminal Analog Output Terminal I/O Interface Converts Binary Data into Analog Output Data Two outputs available. High resolution of 1/6000. Conversion is possible within a range of 5% to 105% FS. High conversion

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes Sorensen XG 1700 Series 1700 W 1700 Watt, 1U Programmable DC Power Supplies 6 600 V Industry Leading Power Density Up to 1700 Watts in 1U Standard Digital Interfaces USB&RS232/485 LXI Ethernet and Isolated

More information

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines GASBOARD 5020 is an analyser for the control of exhaust gases from gasoline or LPG engines; it integrates non dispersive

More information

Environment Clean Room Specification

Environment Clean Room Specification Environment Clean Room Specification ISO Class 4 *1 (ISO14644-1) Built-in vacuum piping Possible to mount the main body without removing the external cover etc. Body-integrated linear guide specification

More information

flowtronic Sensor Series S8005 flowtronic Sensor Series S8005 Product Information Version GREGORY Technology GmbH

flowtronic Sensor Series S8005 flowtronic Sensor Series S8005 Product Information Version GREGORY Technology GmbH Product Information Version 11.04.2016 GREGORY Technology GmbH www.flowtronic.de Introduction The flowtronic sensors are developed for fuel consumption measurement of internal combustion engines. Today

More information

Compact And High-Performance Of 2-Phase Stepper Motor Driver. RUN current

Compact And High-Performance Of 2-Phase Stepper Motor Driver. RUN current -Phase Unipolar Stepper Motor Driver Compact nd High-Performance Of -Phase Stepper Motor Driver Features Unipolar constant current drive type Enable to brake when it stops by STOP current adjustment Low

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Low Profile DC Power Supply with Zero Voltage Soft Switching

Low Profile DC Power Supply with Zero Voltage Soft Switching Sorensen XFR Series Low Profile DC Power Supply with Zero Voltage Soft Switching Analog programming Zero voltage soft switching Constant voltage or constant current operation with automatic crossover and

More information

0.6A, 1.5A, 2.25A, 3A/Phase

0.6A, 1.5A, 2.25A, 3A/Phase 2-Phase Bipolar motor Driver Compact 2-Phase stepper motor driver Features Easy installation with compact size(w85 H21 D64mm) Bipolar constant current drive type Current decay mode decreases vibration

More information

AS Series. RK Series. UMK Series ASX Series 0.36 /0.72. CRK Series. CMK Series 1.8. RBK Series. PK Series 1.

AS Series. RK Series. UMK Series ASX Series 0.36 /0.72. CRK Series. CMK Series 1.8. RBK Series. PK Series 1. A Stepping Motors Stepping Motors Introduction A-2 Introduction AC Input Stepping Motor and Driver Packages DC Input Stepping Motor and Driver Packages Stepping Motors (Motor Only) A-269 A-24 High Efficiency

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

3550 series BATTERY HiTESTER

3550 series BATTERY HiTESTER 3550 series BATTERY HiTESTER Component Measuring Instruments Model 3551 for high-capacity batteries completes line-up Model 3550 for medium-capacity alkali and lead-acid storage batteries: UPS and similar

More information

AR-7240B ANALOG ENGINE TACHOMETER INSTRUCTION MANUAL ONO SOKKI CO., LTD.

AR-7240B ANALOG ENGINE TACHOMETER INSTRUCTION MANUAL ONO SOKKI CO., LTD. AR7240B ANALOG ENGINE TACHOMETER INSTRUCTION MANUAL ONO SOKKI CO., LTD. Warranty 1. This product is covered by a warranty for a period of one year from the date of purchase. 2. This warranty covers freeofcharge

More information

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications Product Information ECN 425 EQN 437 Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications 4/2014 ECN 425, EQN 437 Rotary encoders for absolute position

More information

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for

More information

MULTICAL 6M2. Data sheet

MULTICAL 6M2. Data sheet Data sheet MULTICAL 6M2 Tailored for mixed fluids Data loggers Info loggers Data backup in case of power failure Measurement at subzero temperatures Configurable fluid type and concentration level Contents

More information

Flat Hollow Shaft AC Servo Motor HMA Series

Flat Hollow Shaft AC Servo Motor HMA Series Flat Hollow Shaft AC Servo Motor HMA Series New high-performance hollow-shaft servo motors are available in five sizes. Flat design features a large through-hole to allow cables, shafts or lasers to pass

More information

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 Data sheet MULTICAL 6L2 Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 M15 0200 Contents Calculator functions 3 Cabinet design 7 Approved meter data 8 Electrical

More information

Flash Point Process Analyzer

Flash Point Process Analyzer Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,

More information

MD2U Series 2-Phase Unipolar Stepper Motor Driver

MD2U Series 2-Phase Unipolar Stepper Motor Driver MDU Series -Phase Unipolar Stepper Motor Driver Compact nd High-Performance Of -Phase Stepper Motor Driver Features Unipolar constant current drive type Enable to brake when it stops by STOP current adjustment

More information

Superstatic 440. Static Heat- and Cooling Meter. Application

Superstatic 440. Static Heat- and Cooling Meter. Application Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features M1500 Plus Noninvasive Inline DSP Ultrasonic Flowmeter Accuracy ± 2% of Reading All wetted parts made of PFA Contamination free from ions or particles Minute flow measurements down to 4 ml/min* Easy configuration

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

Space-saving installation Flexible motor mounting

Space-saving installation Flexible motor mounting Space-saving installation Flexible motor mounting compatible!! Pulse train input compatible Automatic actuator recognition Addition of new controller compatible with pulse trains Enables current position

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

CAN and Serial Instrumentation

CAN and Serial Instrumentation Instrumentation Models 3140 and 3141 www.curtisinstruments.com 1 Curtis Models 3140 and 3141 are designed to display critical vehicle and motor controller data in an easy-to-read and attractive LCD. The

More information

KEPCO Will Point You In The Right Direction!

KEPCO Will Point You In The Right Direction! Looking For A High Power, Low Profile Power Supply? KEPCO Will Point You In The Right Direction! -9 AN ISO 900 COMPANY You'll Always Find What You Need At Kepco KLN Series Programmable Power Supply: 0W

More information

SHOCK ABSORBER/DAMPER TESTING MACHINE

SHOCK ABSORBER/DAMPER TESTING MACHINE SHOCK ABSORBER/DAMPER TESTING MACHINE Dampening force of a shock absorber is directly proportional to velocity and this parameter needs to be precisely controlled. A small variation of 1mm in a stroke

More information

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR approved BASIC FEATURES Easy Front Key Setting compliance A 7-segment LED displays input and

More information

1291BL Series Technical Specification Single Axis Position and Rate Table System

1291BL Series Technical Specification Single Axis Position and Rate Table System Datasheet 1291BL Series Technical Specification Single Axis Position and Rate Table System DESCRIPTION The Model 1291BL Single Axis Position and Rate Table System is designed to provide precise position,

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK. Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors R-Series Models RP and RH Ethernet POWERLINK SENSORS Document Part Number 551191 Revision A Data Sheet Model RP Profile-style

More information

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature MEMS Mass Flow Sensor D6F-P A Compact, High-performance Flow Sensor with Dust Segregation Structure. Built in Dust Segregation System (DSS) with cyclone flow structure, diverts particulates from sensor

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

Automation for a Changing World. Delta AC Servo Drive ASDA-A2-E Series

Automation for a Changing World. Delta AC Servo Drive ASDA-A2-E Series Automation for a Changing World Delta AC Servo Drive ASDA-A2-E Series Introduction Delta's ASDA-A2-E, an advanced AC Servo Drive with an EtherCAT communication interface, complies with IEC61158 and IEC61800-7

More information

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability Revision 2017-08-15 Ultrasonic energy meters Flanged ultrasonic energy meters, intended for heating or cooling. Size DN25 DN100 Nominal flow 3.5 60 m³/h For horizontal or vertical mounting No data loss

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter 1 京制 01050054 号 Instruction Manual DMF-1-Series Coriolis Mass Flow Meter Beijing Sincerity Automatic Equipment Co., LTD Tel: +86(010)52073959/ 52073956 18600270515 2 NOTICE We thank you very much for your

More information

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry.   FEATURES DESCRIPTION High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry FEATURES Primary standard, dimensionally based piston prover system Accuracy: CalTrak 500: up to +/- 0.35% of reading mass

More information

Fluidic Oscillation Compact Heat Meter

Fluidic Oscillation Compact Heat Meter Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter a detachable integrator with a wide range of communications

More information

Weatherproof Tubular Slip Ring Assembly

Weatherproof Tubular Slip Ring Assembly Weatherproof Tubular Slip Ring Assembly Model B8-4.3W 8 circuit weatherproof slip ring Compact design Mounts on shafts up to 4.3 [109.2 mm] in diameter Permanently lubricated bearings Rugged stainless

More information

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL Dual Rating NRTL/C CERTIFIED Technologies Inc. mgitech.com Sensor/Sensorless Vector Control Dual current rated for constant and variable torque Auto

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

UAV engine EFI components Specifications Manual

UAV engine EFI components Specifications Manual UAV engine EFI components Specifications Manual -In miniature sizes - For 20cc to 300cc engines V1.7 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED Http://www.ecotrons.com Note: If you are not sure about

More information

G5-series AC Servo Drives with Built-in EtherCAT Communications

G5-series AC Servo Drives with Built-in EtherCAT Communications s with Built-in R88D-KN@-ECT Contents Ordering Information Specifications General Specifications Characteristics Servo Drives with Single-phase 100 VAC Input Power Servo Drives with Single-phase or Three-phase

More information