TV PELLET 400/3N~/50. Power inlet. Diameter 1/2 GAS. Water inlet. Diameter 1 GAS. Steamer drain. Diameter 200 mm. Steam exhaust output

Size: px
Start display at page:

Download "TV PELLET 400/3N~/50. Power inlet. Diameter 1/2 GAS. Water inlet. Diameter 1 GAS. Steamer drain. Diameter 200 mm. Steam exhaust output"

Transcription

1 TV ELLET - Horizontal flame pellet burner with door for 1st smoke channel cleaning - Cochlea for burner feeling L= Standard pellet tank (capacity 250 kg. ab.) - ellet feeng pipe (extractable) - Vertical flame burner for pellet / multifuel with tank (120 kg. ab.) - Right side furnace + rear cleaning door - Front cleaning door for 1st smoke channel (included in the furnace) - Front cleaning door for 2nd and 3rd smoke channel - Side rear cleaning door (Optional burner flame horizontal) - Inspection rear flue cleaning - urner control unit - Kits help draw (Optional) ower inlet Water inlet Steamer drain Steam exhaust output Fume exhaust pipe 400/3N~/50 Diameter 1/2 GAS Diameter 1 GAS Diameter 200 Diameter 150 (mod. ) Diameter (mod. 206)

2 HORIZONTAL FLAME URNERS (applicazione sotto bancale) A = 400 with standard pellet tank, 600 with HC pellet tank VERTICAL FLAME URNERS (applicazione laterale) 2800 wth 2-speed motor 3000 with integrated loang device, for heights below to request availability 01. Horizontal flame pellet burner with door for 1st smoke channel cleaning 02. Cochlea for burner feeling L= Standard pellet tank (capacity 250 kg. ab.) 04. ellet feeng pipe (extractable) 05. Vertical flame burner for pellet / multifuel with tank (120 kg. ab.) 06. Right side furnace + rear cleaning door 07. Front cleaning door for 1st smoke channel (included in the furnace) 08. Front cleaning door for 2nd and 3rd smoke channel 09. Side rear cleaning door (Optional burner flame horizontal) 10. Inspection rear flue cleaning 11. urner control unit 12. Kits help draw (Optional) VERTICAL FLAME URNERS - It s a multifuel: it can burn various solid combustibles (e.g. wood-chips, olives/nuts residues, pellets of any kind) - Self-cleaning; it does not need cleaning - You can have a be-fuel oven heated by a lateral pellet/multifuel burner and a frontal gas or esel burner - Since the oven is equipped with lateral wood furnace, the oven can be heated by wood (removing the burner and installing grids) - It s bulkier - It requires almost daily charge of pellets, because silos has small capacity

3 CLEANING URNER Grid and head air holes cleaning: daily frequency (cleaning time 1 ).You reach the grid by opening the burner door with its handle. Recoended tool: st/st brush. With the automatic pneumatic burner cleaning kit (optional) cleaning frequency becomes weekly. OVEN irst Channel Cleaning Frequency: weekly (time to perform the operation: 10 minutes), you reach the channel opening the burner door with a handle and rear outlet (if any). Recoended Tool: vacuum cleaner for ashes. Second And Third Channel Cleaning Frequency: quarterly (time to perform the operation: 30 minutes), you reach channels by opening the front vent. Recoended tool: vacuum cleaner for ashes. Cleaning Frequency of pipes front area in the first channel, from fouling: quarterly (time to perform the operation: 30 minutes). Recoended Tool: brush with steel bristles. Cleaning inside the oven flue: every six months (time to perform the operation: 10 minutes), you reach by opening the inspection nozzle in the rear of the oven. Recoended Tool: brush with stainless bristles. ELLET TANK ellet tank cleaning: six-month frequency. Empty the tank from the pellet, completely,through the scharge hatch, and remove any residual sawdust on the walls and at the entrance of the cochlea. Recoended tool: cinder vacuum cleaner. CHIMNEYS (not supplied by olin): Chimneys cleaning: six-month frequency. Check the contion of the chimneys and remove any residue (pay particular attention to the horizontal sections). Recoended tool: cinder vacuum cleaner. AUTONOMY The capacity of the standard, made of stainless steel, tank allows an autonomy range of 3 working days (for ovens of Kcal/h) or 2 working days (for ovens of Kcal/h) assuming a 5-hours working day. With HC pellet tank oven autonomy is doubled ELLET TANK - HC MODEL St/st tank with large crystal for ieate splay of fuel level Large capacity (600lt, 400kg pellet) for an autonomy than double the standard tank St/st lid with opening/closing pneumatic pistons Hatch for pellet residual cleaning resetting for level sensor kit for pellet with warning light (as option)

4 Chambers aking Surface Dim. Length Useful mension chambers Height Installed power Thermic Electrical Minimum door width Weight n mq kcal/h kw kg 3,2 / 84x , x ,2 / 84x , x ,3 / 84x , x ,3 / 84x , x ,7 / 84x , x ,1 / 84x , x ,4 / 84x , ,0 650x ,2 / 84x , x ,0 / 84x , x ,5 / 84x , x ,7 / 84x , x ,6 / 84x , x ,3 / 124x , x ,4 / 124x , x ,5 / 124x , x ,0 / 124x , x ,6 / 124x , x ,3 / 124x , ,0 650x ,6 / 124x , x ,8 / 124x , x ,0 / 124x , x ,0 / 156x , x ,6 / 156x , x ,3 / 156x , x ,0 / 156x , x ,5 / 156x , ,0 650x ,7 / 156x , x ,0 / 156x , x ,0 / 156x , x ,0 / 156x , x ,4 / 186x , x ,5 / 186x , x ,8 / 186x , x ,0 / 186x , x ,0 / 186x , ,2 650x ,0 / 186x , x ,0 / 186x , x ,0 / 186x , x ,0 / 186x , x ,0 / 234x , x ,9 / 234x , x ,9 / 234x , x ,0 / 234x , x ,0 / 234x , ,2 650x ,0 / 234x , x ,2 / 234x , x ,2 / 234x , x ,2 / 234x , x ,6 / 248x , x ,8 / 248x , x ,0 / 248x , x ,0 / 248x , x ,2 / 248x , ,2 650x ,5 / 248x , x ,2 / 248x , x ,6 / 248x , x ,0 / 248x , x

5 UNA GAMMA COMLETA DI OLTRE 90 MODELLI T.V. SYNT serie 206 T.V. SYNT serie camere 4 camere 5 camere camere camere camere 3 camere 4 camere 5 camere Mod. Mod. 124 Mod. 156 Mod. Mod. 124 Mod. 156 Mod. Mod. 124 Mod Mod. 186 Mod. 234 Mod. 248 Mod. 186 Mod. 234 Mod. 248 Mod. 186 Mod. 234 Mod Sporgenza Sporgenza per per corpo corpo fornacella fornacella a legna legna con con carico carico laterale laterale (optional) (optional) Nella Nella versione versione la la profontà profontà è Sporgenza per corpo fornacella a legna con carico laterale (optional) ossibilità ossibilità Nella versione installare installare la bruciatore bruciatore profontà a è biomassa biomassa (pellet, (pellet, cippato...) cippato...) ossibilità installare bruciatore a biomassa (pellet, cippato...) Ing. & C. S.p.A. Viale dell Industria, Verona - Italy - Tel polin@polin.it

PASTRY LINE. Automatic dough sheeters

PASTRY LINE. Automatic dough sheeters PASTRY LINE Automatic dough sheeters All the stability of automatic dough sheeters Available in a wide range of models, the main strength of Ostali semiautomatic and automatic dough sheeters lies in their

More information

HP14/20/28 P50 P75 P100/120 P150/170/200 P500

HP14/20/28 P50 P75 P100/120 P150/170/200 P500 Wood pellet range: HP14/20/28 P50 P75 P100/120 P150/170/200 P500 performance max. cons. part cons. range load at max. ** load at part ** efficiency kw kw kg/h kw kg/h % Wood pellet units: HP14 4-14 18

More information

OIL BURNERS MAIOR P 45 AB. techniques for energy saving MODEL. HYDRAULIC SYSTEM 220/380 V 60 Hz LB

OIL BURNERS MAIOR P 45 AB. techniques for energy saving MODEL. HYDRAULIC SYSTEM 220/380 V 60 Hz LB OIL BURNERS techniques for energy saving MODEL MAIOR P 45 AB HYDRAULIC SYSTEM 220/380 V 60 Hz LB462 09.12.99 TECHNICAL DATA MODEL MAIOR P 45 AB Thermal power max. kcal/h 450.000 kw 522 Thermal power min.

More information

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM DIESEL SPACE HEATER - SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER ASSEMBLY 3. FUEL PUMP ASSEMBLY

More information

Biofuel systems for quality-conscious customers

Biofuel systems for quality-conscious customers Biofuel systems for quality-conscious customers TWINHEAT investing in the future Since 1979, TWINHEAT has been dedicated to developing and producing burner systems and fully automatic silo systems for

More information

MULTIFIRE. High temperature dual fuel burner

MULTIFIRE. High temperature dual fuel burner MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,

More information

Biofuel systems for quality-conscious customers

Biofuel systems for quality-conscious customers Biofuel systems for quality-conscious customers TWINHEAT investing in the future Since 1979, TWINHEAT has been dedicated to developing and producing burner systems and fully automatic silo systems for

More information

SIMPLEX BIG 2B PARTS WASHERS WITH ROTARY BASKET, PLC AND TOUCHSCREEN EQUIPMENT SIMPLEX BIG 2B

SIMPLEX BIG 2B PARTS WASHERS WITH ROTARY BASKET, PLC AND TOUCHSCREEN EQUIPMENT SIMPLEX BIG 2B SIMPLEX BIG 2B PARTS WASHERS WITH ROTARY BASKET, PLC AND TOUCHSCREEN Simplex Big is a system ideal for the automatic washing of medium and large size mechanical parts. The washing is carried out by the

More information

TECHNICAL INFORMATION BIOMASS SOLUTIONS FOR A MORE ECOLOGICAL AND ECONOMICAL WORLD

TECHNICAL INFORMATION BIOMASS SOLUTIONS FOR A MORE ECOLOGICAL AND ECONOMICAL WORLD TECHNICAL INFORMATION BIOMASS SOLUTIONS FOR A MORE ECOLOGICAL AND ECONOMICAL WORLD TECHNICAL INFORMATION Easy handling by microprocessor-control! Logically organized menus makes for easy operation of the

More information

TECHNICAL INFORMATION. performance max. cons. part cons. range load at max. ** load at part ** efficiency kw kw kg/h kw kg/h % Wood chip units:

TECHNICAL INFORMATION. performance max. cons. part cons. range load at max. ** load at part ** efficiency kw kw kg/h kw kg/h % Wood chip units: PRODUCT RANGE Wood chip range: HS25/35 HS50 HS75 HS100/120 HS150/170/200 HS500 performance max. cons. part cons. range load at max. ** load at part ** efficiency kw kw kg/h kw kg/h % Wood chip units: HS15

More information

More than 40 years' experience and quality you can rely on 2014/15. Heating systems

More than 40 years' experience and quality you can rely on 2014/15. Heating systems More than 40 years' experience and quality you can rely on 2014/15 Heating systems An abundance of energy-saving and professional combination options Made in Denmark CN Maskinfabrik A/S specialises in

More information

Automatic CFD optimisation of biomass combustion plants. Ali Shiehnejadhesar

Automatic CFD optimisation of biomass combustion plants. Ali Shiehnejadhesar Automatic CFD optimisation of biomass combustion plants Ali Shiehnejadhesar IEA Bioenergy Task 32 workshop Thursday 6 th June 2013 Contents Scope of work Methodology CFD model for biomass grate furnaces

More information

Routine Burner Service

Routine Burner Service Routine Burner Service WARNING Rural Energy Enterprises, Inc. does not accept liability for the improper use of this information. Installation, service, and maintenance of heating equipment should be performed

More information

and wherein the combustion does not involve liquid or gaseous fuels, or pulverulent fuel burned in suspension.

and wherein the combustion does not involve liquid or gaseous fuels, or pulverulent fuel burned in suspension. CPC - F23B - 2018.05 F23B METHODS OR APPARATUS FOR COMBUSTION USING ONLY SOLID FUEL (for combustion of fuels that are solid at room temperatures, but burned in melted form, e.g. candle wax, C11C 5/00,

More information

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

PRESSURIZED STEEL BOILER WITH REVERSED FLAME smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630

More information

GAS BURNERS BLU 3000 PR BLU 4000 PR

GAS BURNERS BLU 3000 PR BLU 4000 PR GAS BURNERS techniques for energy saving MODELS BLU 3000 PR BLU 4000 PR 220/380 V 60 Hz L.P.G. LB 450 03.03.97 TECHNICAL DATA MODELS BLU 3000 PR BLU 4000 PR Thermal power max. kcal/h 2.580.000 3.440.000

More information

Analogue and digital time and twilight switches

Analogue and digital time and twilight switches System pro M compact Analogue and digital time and twilight switches 2CSC440007B0201 Controlling load switching in a system improves its functionality by rationalizing power consumption. This means that

More information

APPROVED HETAS APPROVED

APPROVED HETAS APPROVED APPROVED HETAS APPROVED Wood and Multi-fuel Stoves Highlander 5 Dunsley Highlander-3 The Highlander-3 has been designed to give you cleaner burn and superb efficiency. The Highlander-3 has interchangeable

More information

DEPOSITORS RDT 215 & TWINY

DEPOSITORS RDT 215 & TWINY DEPOSITORS RDT 215 & TWINY DEPOSITOR RDT 215 Industrial reciprocating moving head depositor for confectionery, wire cut one colour and soft centre cookies with the addition of a hopper for the filling.

More information

SPARE PARTS LIST - July

SPARE PARTS LIST - July Versions for CANADA SPARE PARTS LIST - July 2005 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is

More information

Pro-Fab Industries Empyre Elite 100 V1 (815460) Service Parts List R2 Page 1 of 8

Pro-Fab Industries Empyre Elite 100 V1 (815460) Service Parts List R2 Page 1 of 8 ITEM NO. PAGE PART NO. DESCRIPTION QTY. 1 2 816050 Key, Lock 2 2 2 815813 Latch 2 3 2 815789 Smoke Curtain 1 4 2 815718 Side Panel, L/H 1 5 2 801045 Insulation, Semi-Rigid 5 shts. 6 2 815947 Deflector,

More information

ADVANCE Easy Moving. And pellet becomes easy! The fi rst COMPLETE SYSTEM made to feed biomass boilers. The boiler is automatically fed instantly!

ADVANCE Easy Moving. And pellet becomes easy! The fi rst COMPLETE SYSTEM made to feed biomass boilers. The boiler is automatically fed instantly! ADVANCE Easy Moving www.advanceeasymoving.com And pellet becomes easy! The boiler is automatically fed instantly! The fi rst COMPLETE SYSTEM made to feed biomass boilers The fi rst universal and complete

More information

CONDOR CLASSIC STEAM FIRE TUBE. Design pressure up to 21 bar Steam production from to Kg/h

CONDOR CLASSIC STEAM FIRE TUBE. Design pressure up to 21 bar Steam production from to Kg/h FIRE TUBE Design pressure up to 21 bar Steam production from 1.500 to 15.000 Kg/h INDUSTRIAL BOILER ITALY S.R.L. Offices and Production Unit: Via E. Fermi, 64/66-24050 GRASSOBBIO (BG) Cod. Fisc. / P.IVA

More information

SETUP & DAILY USE INSTRUCTIONS

SETUP & DAILY USE INSTRUCTIONS TM easycomposites share the knowledge SETUP & DAILY USE INSTRUCTIONS Composites Vacuum Pump VP425 VP3400 1 CONTENTS 1. Introduction 2 2. First Time Use - Setup Instructions 3 1. Fill pump with oil 3 2.

More information

1070 SERIES ULTRA LOW NO X

1070 SERIES ULTRA LOW NO X CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing

More information

Complete firing plants with silo, dosing machine, assembly and the commissioning. Reliable customer service. Service and assembly from one hand

Complete firing plants with silo, dosing machine, assembly and the commissioning. Reliable customer service. Service and assembly from one hand HOT GAS GENERATOR COMBUSTION CHAMBERS System Dr. Schoppe for PULVERIZED LIGNITE fuel oil and gas from 100 kw up to 300 MW CARBOTECHNIK Hot gas generator 40 MW for pulverized lignite, fuel oil and sewer

More information

Absolute43. Service Parts (Black) (Majolica Brown) Part number list on following page.

Absolute43. Service Parts (Black) (Majolica Brown) Part number list on following page. Pellet Stove 1-90-777000-1 () 1-90-777000-14 (Majolica Brown) 2 3 4 5 6 1 31 30 29 7 9 8 24 25 23 22 28 27 26 21 10 20 11 12 13 14 15 16 19 17 18 Part number list on following page. 11/17 IMPORTANT: THIS

More information

Boiler Operation, Maintenance, and Settings. Matthew Baxter Technical Director, Core Biomass

Boiler Operation, Maintenance, and Settings. Matthew Baxter Technical Director, Core Biomass Boiler Operation, Maintenance, and Settings Matthew Baxter Technical Director, Core Biomass How is a boiler designed to Operate? The boiler must be designed around the key characteristics of the fuel,

More information

ECONOMATIC STEEL SHELL BOILERS

ECONOMATIC STEEL SHELL BOILERS ECONOMATIC STEEL SHELL BERS ECONOMATIC SERIES Since 1985 Stokvis has been supplying high quality products to the heating industry. The Economatic boilers are no exception.they are 3 pass reverse fl ame,

More information

INDUSTRIAL GENERATORS. steam or overheated water 97/23/CE - P.E.D. certified

INDUSTRIAL GENERATORS. steam or overheated water 97/23/CE - P.E.D. certified 05-0514 INDUSTRIAL GENERATORS steam or overheated water 97/23/CE - P.E.D. certified TECHNIQUE, COMPETENCE, EXPERIENCE OR INDUSTRY The steam and overheated water production cost is a decisive factor for

More information

CODE OF GOOD PRACTICE

CODE OF GOOD PRACTICE CODE OF GOOD PRACTICE FOR THE OPERATION OF LIQUID FUEL FIRED COMMERCIAL, INDUSTRIAL AND DOMESTIC APPLIANCES 1st June 1972 PRINTED BY THE GOVERNMENT PRINTER HONG KONG 94157 140K 7/72 INTRODUCTION CONTENTS

More information

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency M K MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency Gas/ gas oil working Output from 44 to 291,7 (from 37.840 to 250.862 of water efficiency). Pipe

More information

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course Mobile Diesel Heaters GRY-D / GRY-I Service Training Course 1 Rev. No. 3 January 24, 2011 GRY-I Indirect-fired Diesel Heaters GRY-I 15 WU GRYP 50 AP GRY-I 25 WU GRYP 90 AP GRY-I 40 WU GRYP 135 AP 2 GRY-D

More information

Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar

Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar DATASHEET PSB SERIES Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar Oil / Gas / HFO Fired Steam Boiler Three pass reverse flame steam boiler Without Economiser Maximum Permissible operating

More information

Specifications of MAXON VALUPAK burners for 50 Hz operation

Specifications of MAXON VALUPAK burners for 50 Hz operation 1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size

More information

User s Manual for the LAMBDA 5 S Control Unit

User s Manual for the LAMBDA 5 S Control Unit User s Manual for the LAMBDA 5 S Control Unit 1 USER S MANUAL Contents User s Manual 3 Instructions for Using the Control Unit.....6 SIMATIC PANEL control terminal (OP77A or P77B)..8 Parameter setting

More information

Commitment to quality Glass cook tops Quality in cast iron Combustion air control Enamel finish High capacity ovens

Commitment to quality Glass cook tops Quality in cast iron Combustion air control Enamel finish High capacity ovens Commitment to quality Hergóm carries out and guarantees the entire production process of its cooking appliances, including design, castings and finish product. Hergóm uses the finest raw materials and

More information

SPARE PARTS CATALOGUE

SPARE PARTS CATALOGUE SPARE PARTS CATALOGUE - January 2008 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning

More information

FlexPAK 800 DX. The leading extraction solution. Always the right capacity.

FlexPAK 800 DX. The leading extraction solution. Always the right capacity. The leading extraction solution. Always the right capacity. The FlexPAK DX high vacuum unit represents the foremost solution on the market. The unit is designed for the extraction of welding fumes, grinding

More information

MOUNTING INSTRUCTIONS

MOUNTING INSTRUCTIONS MOUNTING INSTRUCTIONS PULSE PULSE PRO T6430 - Pulse in ABS T6530 Pulse in metal satin chrome T6630 Pulse Pro in metal satin chrome OPTIONS /B black unit /G grey unit /GR with rubber keypad in grey /BR

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

Stoves with Perfect Combustion

Stoves with Perfect Combustion Stoves with Perfect Combustion HS Flamingo Wood Stoves Advantages of Wood Stoves secondary combustion (ensures clean glass and complete combustion of gaseous components thanks to special intake of secondary

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data

More information

CODE MODEL TYPE PRESS GW 605 T80

CODE MODEL TYPE PRESS GW 605 T80 Installation, use and maintenance instructions Pressure jet burner CODE MODEL TYPE 3473784 PRESS GW 605 T80 291 (2) - 08/2012 Thermal power 107 / 178-350 kw - 92.000 / 153.000-301.000 kcal/h Output 9/15-30

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,

More information

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz OIL BURNERS MINOR 1 Snorkel 240 Volt 50 Hz 420010675700 04.06.2015 TECHNICAL DATA MODEL MINOR 1 SNORKEL Thermal power max kcal/h 25500 kw 29,6 Thermal power min kcal/h 17300 kw 20 Max capacity light oil

More information

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F TECHNICAL MANUAL REX/REX F/REX K/REX K F REX DUAL/REX DUAL F PRESSURISED STEEL BOILERS INDEX 1 GENERAL WARNINGS... 4 2 TECHNICAL SPECIFICATIONS... 5 2.1 REX/REX K/REX F/REX K F 7-130 BOILER... 5 2.2 REX/REX

More information

11/2011. Mod: G17/BRI8-N. Production code:

11/2011. Mod: G17/BRI8-N. Production code: 11/2011 Mod: G17/BRI8-N Production code: 373104 SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO BRASIERA GAS-ELETTRICA E700XP GAS-ELECTRIC BRATT-PAN E700XP PNC Model Ref Pag. Brand Version Notes 371103

More information

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS

More information

LESS IS MORE HORIZONTAL COOKING RANGE

LESS IS MORE HORIZONTAL COOKING RANGE LESS IS MORE HORIZONTAL COOKING - 600 RANGE INDEX LESS IS MORE 04 ONE KITCHEN, ENDLESS POSSIBILITIES 12 LESS IS MORE. The 600 Cooking Range is an answer from Fagor Industrial to the needs of professionals

More information

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw www.ecoflam-burners.com PRODUCT RANGE 2015 A COMPLETE RANGE OF BURNERS FROM 17 TO 34000 kw CUTTING-EDGE BURNERS FOR HEATING AND INDUSTRIAL APPLICATIONS Our proposal Ecoflam offers a full range of blown

More information

ETHANOL 1100 FIREPLACE OWNER S MANUAL

ETHANOL 1100 FIREPLACE OWNER S MANUAL ETHANOL 1100 FIREPLACE OWNER S MANUAL USER MANUAL & ASSEMBLY INSTRUCTIONS Important: Read these instructions and warnings carefully so as to familiarize yourself with the appliance before attempting to

More information

FIREPLACES COLLECTION

FIREPLACES COLLECTION FIREPLACES COLLECTION Bio-Blaze WWW. BIO-BLAZE.COM 2 0 1 6 contents 06 Wall mounted 24 Free standing 38 Table Fireplaces 44 Grates 46 Burners 46 Accessories ABOUT US... ABOUT... BIO-BLAZE, A FAMILY OWNED

More information

OVENS & INCUBATORS RESPONSE TO THE DEMANDS OF MODERN LABORATORY. INCUBATORS from 5 to 240 lt. OVENS from 5 to 720 lt

OVENS & INCUBATORS RESPONSE TO THE DEMANDS OF MODERN LABORATORY. INCUBATORS from 5 to 240 lt. OVENS from 5 to 720 lt OVENS & INCUBATORS RESPONSE TO THE DEMANDS OF MODERN LABORATORY INCUBATORS from 5 to 240 lt OVENS from 5 to 720 lt series STZ Mini drying ovens Natural convection drying ovens with notable thermal stability.

More information

Proper Servicing of the Fuel Screens on Enstrom F Series Piston Engine Helicopters

Proper Servicing of the Fuel Screens on Enstrom F Series Piston Engine Helicopters Proper Servicing of the Fuel Screens on Enstrom F Series Piston Engine Helicopters Proper cleaning of the fuel filter assembly: reference page MM-13-85 para. (4) of the F28F and 280F Series Maintenance

More information

BARBECUE COMPONENT & REPLACEMENT PARTS 2015 LIST PRICE SHEET EFFECTIVE NOVEMBER 1, 2014 WARMING RACKS A83

BARBECUE COMPONENT & REPLACEMENT PARTS 2015 LIST PRICE SHEET EFFECTIVE NOVEMBER 1, 2014 WARMING RACKS A83 BARBECUE COMPONENT & REPLACEMENT PARTS 2015 LIST SHEET EFFECTIVE NOVEMBER 1, 2014 WARMING RACKS SIZE CODE DIMENSIONS SHIP Warming Rack, Heavy Duty Gauge Stainless Steel SECTION INDEX E10 48 X 7 3 / 4 9

More information

COMMERCIAL BOILERS Eco-HK / Eco-PK KW

COMMERCIAL BOILERS Eco-HK / Eco-PK KW www.hargassner.com COMMERCIAL BOILERS Eco-HK / Eco-PK 150 225 KW COMMERCIAL BOILERS Eco-HK / Eco-PK Features and benefits of the Eco-HK & Eco-PK Energy-saving -Operation Speed-controlled EC-exhaust fan

More information

FIERY Home Cinema Fireplace inserts

FIERY Home Cinema Fireplace inserts Live fire is a show in itself. Modern interior design respects its beauty. The less ornaments the better. Raw concrete, stone, wood, ceramic, gypsum, glass and steel. In such a company, fire looks its

More information

ONE STAGE GAS BURNERS RDBS SERIES

ONE STAGE GAS BURNERS RDBS SERIES ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high

More information

Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048

Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048 Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048 Installation and Operation Instructions Rev. 2009-1 Dear Cookshack Customer: Your Cookshack Charbroiler will last for years producing

More information

MAIN 5 SPARE PARTS CATALOGUE. - March

MAIN 5 SPARE PARTS CATALOGUE. - March MAIN 5 SPARE PARTS CATALOGUE - March 2013 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning

More information

RAFAKO s proecological investments boilers and biomass installations

RAFAKO s proecological investments boilers and biomass installations RAFAKO s proecological investments boilers and biomass installations Presented: Krzysztof JANECZEK 22 23 March 2017 r. Content: 1. Introduction. 2. Biomass boilers. 3. Modernization of PC boiler at Stalowa

More information

PROPANE FORGING FURNACE H3

PROPANE FORGING FURNACE H3 PROPANE FORGING FURNACE H3 Forging Furnaces Nargesa are used in blacksmiths workshops for ornamental forge, moulding iron up to achieving the desired shapes. REQUEST QUOTATION Please fill up the following

More information

Price list. W/o VAT / HORS TVA

Price list. W/o VAT / HORS TVA 2016 Price list W/o VAT / HORS TVA BOILERS INTEGRA 28 4 HR EVO 18 PLUS 5 HR EVO 24 PLUS 6 STOVES HRV 100 TOUCH 7 HRV 200 TOUCH 9 HRV 120 STYLE 11 HRV 140 TOUCH 8 HRV 160 TOUCH 10 INFINITY 12 AURORA GLASS

More information

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

LDG6000SA DIESEL GENERATOR OWNERS MANUAL LDG6000SA DIESEL GENERATOR OWNERS MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY Preface Thank-you for purchasing this generator. This operation manual contains information

More information

LUI HYDRAULIC A-FRAME DRIVE. 4 Estaciones. For impregnation and washing. With pump and tank for products.

LUI HYDRAULIC A-FRAME DRIVE. 4 Estaciones. For impregnation and washing. With pump and tank for products. LUI-005 1 JIGGER make MEZZERA. Year 1990. Width 2.000 mm. Hydraulic System. Diameter of fabric 1.100 mm. Circulation Pump. Microprocessor make JUNKER / OBBSA. LUI-006 1 JIGGER make MEZZERA. Year 1990.

More information

PENTOLA DIRETTA 60Lt E700XP BOILING PAN DIRECT HEATING 60Lt E700XP

PENTOLA DIRETTA 60Lt E700XP BOILING PAN DIRECT HEATING 60Lt E700XP SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO PENTOLA DIRETTA 60Lt E700XP BOILING PAN DIRECT HEATING 60Lt E700XP PNC MODEL Ref Description 371254 E7BSGHDN40 60 LT GAS DIRECT BOILING PAN Index Components

More information

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO GS/M SERIES GS /M / 5 3/8 19 The Riello GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed

More information

HBL Save Fuel and Cut Down Emissions with HBL Rentar Fuel Catalyst

HBL Save Fuel and Cut Down Emissions with HBL Rentar Fuel Catalyst Save Fuel and Cut Down Emissions with Rentar Fuel Catalyst May 2015 1 Improving Profits in Business All businesses look to increase their profits Increase in profits happens through increase in sales volume

More information

Models CB024, CB036, CB048

Models CB024, CB036, CB048 Models CB024, CB036, CB048 Please read this entire manual for installation and use of these charbroilers. Failure to follow these instructions could result in property damage, bodily injury or even death.

More information

ADAPTA THE EVOLVING CAPSULE FILLER

ADAPTA THE EVOLVING CAPSULE FILLER ADAPTA THE EVOLVING CAPSULE FILLER ADAPTA The Adapta s DNA has its roots in IMA s 50 years of experience and more than 5,000 capsule filling installations world-wide. This knowledge and experience have

More information

SPARE PARTS CATALOGUE. - September

SPARE PARTS CATALOGUE. - September SPARE PARTS CATALOGUE - September 2014 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning

More information

It has been positively tested during a study carried out by the Department of Machinery, Energy and Transport of the University of Genoa (Italy)

It has been positively tested during a study carried out by the Department of Machinery, Energy and Transport of the University of Genoa (Italy) is a stand-alone device producing Oxyhydrogen, a calibrate mix of Oxygen, Para-hydrogen and ortho-hydrogen which is sent to the engine as an addition to the normally aspired air to help improving combustion.

More information

Industrial vacuum cleaners

Industrial vacuum cleaners Basic 3Phase I-Vac (T40W) and specific B&C (T40WP) versions with SC blower. T40W is a mobile I-vac for liquid&solid. Available with a 100L or 50L bin & as well as with a Gravity Unload system (GU) for

More information

Stoves and inserts CATALOGUE

Stoves and inserts CATALOGUE Stoves and inserts CATALOGUE INSERTS INDEX INSERTS A-85 PLUS A-70 PLUS FREESTANDING STOVES NEW VISION G-100 A-85 Plus... 6 A-70 Plus... 6 G-100... 10 VISION... 12 FREESTANDING STOVES RA-85 Plus... 16

More information

SPARE PARTS CATALOGUE

SPARE PARTS CATALOGUE SPARE PARTS CATALOGUE - March 2014 - North America HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is

More information

Save Fuel and Cut Down Emissions with HBL Rentar Fuel Catalyst

Save Fuel and Cut Down Emissions with HBL Rentar Fuel Catalyst Save Fuel and Cut Down Emissions with HBL Rentar Fuel Catalyst 1 Improving Profits in Business All businesses look to increase their profits Increase in profits happens through increase in sales volume

More information

SMARTWOOD SRL Via Caduti sul don, Villar San Costanzo (CN) Tel

SMARTWOOD SRL Via Caduti sul don, Villar San Costanzo (CN) Tel SMARTWOOD SRL Via Caduti sul don, 31 12020 Villar San Costanzo (CN) Tel +39 0171 910010 e-mail: info@smartwoodsrl.com www.smartwoodsrl.com 1 PRODUCT PORTFOLIO Pellet Mills for Home Use Pellet mills for

More information

Fimap reinvents the sweeping machine!

Fimap reinvents the sweeping machine! Fimap reinvents the sweeping machine! TECHNOLOGY The autonomy of the gasoline engine meets the clean energy of the battery power Up to 7.5 non-stop working hours Very low consumptions and great autonomy:

More information

PRACTICA MID TO HIGH-SPEED CAPSULE FILLING MACHINE

PRACTICA MID TO HIGH-SPEED CAPSULE FILLING MACHINE PRACTICA MID TO HIGH-SPEED CAPSULE FILLING MACHINE PRACTICA The Practica capsule filling machine covers low, medium and highspeed production requirements and performs single product dosing (powder/granulate

More information

ECONOMATIC REX/REXF REX/REXF DUAL STR

ECONOMATIC REX/REXF REX/REXF DUAL STR TECHNICAL MANUAL ECONOMATIC REX/REXF REX/REXF DUAL STR PRESSURISED STEEL BOILERS 96R WALTON ROAD, EAST MOLESEY, SURREY, KT8 0DL Tel. 08707 707 747 Fax. 08707 707 767 info@stokvisboilers.com - www.stokvisboilers.com

More information

Idropulitrici Alta Pressione Aspiratori High Pressure Cleaners Vacuum Cleaners

Idropulitrici Alta Pressione Aspiratori High Pressure Cleaners Vacuum Cleaners Idropulitrici Alta Pressione Aspiratori High Pressure Cleaners Vacuum Cleaners 1401 1 Sede centrale di Modena Modena headquarters 2 Stabilimento di Bomporto Bomporto plant 3 Centro logistico (Bomporto)

More information

Oil, gas and dual fuel burners. Burner series

Oil, gas and dual fuel burners. Burner series Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1 2 Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back

More information

23 years of trouble-free use! A Moderator boiler operating in Sokołów Podlaski.

23 years of trouble-free use! A Moderator boiler operating in Sokołów Podlaski. THIS WAS THEN THIS IS NOW Boilers functioning to this day are a reminder of those times A Moderator boiler operating in Sokołów Podlaski. 23 years of trouble-free use! This boiler was manufactured in 1989

More information

Eclipse Vortometric Burners Series HI

Eclipse Vortometric Burners Series HI Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)

More information

STAR SPARE PARTS LIST

STAR SPARE PARTS LIST STAR SPARE PARTS LIST - January 2005 - WESTEN HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the

More information

Instruction Manual. EAST BROAD TOP #12 Electric & Live Steam

Instruction Manual. EAST BROAD TOP #12 Electric & Live Steam Instruction Manual EAST BROAD TOP #12 Electric & Live Steam EBT #12 Electric Prototype Information East Broad Top # 12 was the first of the six 2-8-2 locomotives that the E.B.T. ordered from Baldwin. The

More information

SILENT AND VERSATILE LIKE NO OTHER. RANGE S - SX NEW RANGE GENERATING SETS

SILENT AND VERSATILE LIKE NO OTHER. RANGE S - SX NEW RANGE GENERATING SETS SILENT AND VERSATILE LIKE NO OTHER. RANGE S - SX 3 0 0 0 r p m EN NEW RANGE GENERATING SETS RANGE S Silenced generating set MOSA S Range generating sets are versatile with high performance built in; available

More information

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels Combustion Equipment Combustion equipment for Solid fuels Liquid fuels Gaseous fuels Combustion equipment Each fuel type has relative advantages and disadvantages. The same is true with regard to firing

More information

Preventative Maintenance Tune-ups

Preventative Maintenance Tune-ups Chapter 14 Preventative Maintenance Tune-ups The preventive maintenance tune-up is the most important service our industry offers. A properly performed tune-up assures the customer that their heating system

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 3747455 G0KI 474T5 90403 (4) - 0/008 TECHNICAL DATA Thermal power output 95 3 kw 8 8 kg/h

More information

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed

More information

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993 ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE GAS FURNACES SYSTEMS 50hz G21Q PULSE21 SERIES UP-FLO GAS FURNACES 11.4 to 27.8 kw (39 000 to 95 000 Btuh) Output Add-On Cooling 5.3 thru 17.6 kw (1-1/2

More information

PNEUMATIC CONVEYING SYSTEMS FOR PELLET & BIOMASS STORAGE SILOS CLEANING AND ASH-CLEANER

PNEUMATIC CONVEYING SYSTEMS FOR PELLET & BIOMASS STORAGE SILOS CLEANING AND ASH-CLEANER PNEUMATIC CONVEYING SYSTEMS FOR PELLET & BIOMASS STORAGE SILOS CLEANING AND ASH-CLEANER Price list 2016 V.01eng PNEUMATIC CONVEYORS WX2 Pneumatic conveyor WX2 Accessories included: control panel with black-lit

More information

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700 Instruction Sheet P/N 397 880 B English Retrofitting Kit Filter Cleaning for Cable Coater ECC 700 Safety Instructions WARNING: Allow only qualified personnel to perform the following tasks. Observe and

More information

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart Service Manual Contents 1. Names of components 2 2. Safety Devices 3 3. Specifications 4 4. Wiring Diagam 4 5. Sequence Time Chart 5 6. 7. 8. Troubleshooting 6 Standard resistance & Voltage 13 Check &

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000

More information

PNEUMATIC TRANSPORT FOR SOLID FUELS Price list ADVANCE Easy Moving

PNEUMATIC TRANSPORT FOR SOLID FUELS Price list ADVANCE Easy Moving ADVANCE www.advanceeasymoving.com PNEUMATIC TRANSPORT FOR SOLID FUELS Price list 2015 INDEX Basic components - NOVA 1 vacuum unit page 2 - NOVA 2 vacuum unit page 2 - Control panel Drive page 2 - Dispenser

More information

MAINTENANCE SCHEDULE

MAINTENANCE SCHEDULE MAINTENANCE SCHEDULE System Check Item Daily 50 250 500 1000 1500 2000 Grease PTO anti-rotating shields Grease and lubricate ales and PTO bearings Grease fan motor (1 pump) (DO NOT OVER GREASE) Grease/Lube

More information

Series RB-J. OIL FREE Screw Compressors for Pneumatic Transport

Series RB-J. OIL FREE Screw Compressors for Pneumatic Transport Series RB-J OIL FREE Screw Compressors for Pneumatic Transport EXPERIENCE In the BETICO GROUP, national leader in the manufacture and sale of compressors since 925, we design and manufacture top quality

More information