1 CDVR33SC7 Direct Vent 21-1/2 (546 mm) Opening Depth 1/2 (12.7 mm) 11-3/4 (299 mm) 11-1/4 (286 mm) 33- (854 mm) Opening Width Opening Height G L A S S V I E W I N G A R E A 27-3/16 W x 15-7/16 H (418 Square Inches) (691 mm x 386 mm) 1-1/4 (31.8 mm) 27-3/16 (691 mm) 15-3/16 (386 mm) 31-11/16 (805 mm) 32-1/4 (819 mm) S TA N D A R D F E AT U R E S Unitized black louver assembly Ember bed burner Ceramic Fiber logs Grate Junction box Nailing tabs for and 15/16 (23.8 mm) 29-7/8 (759 mm) 33-3/8 (848 mm) F I E L D I N S TA L L E D A C C E S S O R I E S Firebrick: Tavern Brown Curved Trim: Black Medium Trim Kit: Black Manual Blower and Cord (160cfm): FK-12 Thermostat Blower (160cfm): BLOT Signature Command Blower (160cfm): BLOTSC (requires purchase of SCSACM & TSFSC) Signature Command Remotes & Thermostats: RMSC, TSMSC, TSTSC, TSFSC, WT) Signature Command Accessories: A/C Accessory, Module and Command Center, Wall Mount Kits Conversion Kits: Natural Gas (CDV33CKNS), LP Gas (CDV33CKPS) Mesh Screen Glass Cover Wood Cabinet Surrounds Designer Facings (Current 300DVB trim, fronts and filigree panels will fit the CDV. Doors and door frames do not.) 2-5/16 (59 mm) 36 (914 mm) 51 (1295 mm) C L 21-15/16 (557 mm) 25-1/2 (648 mm) 36 (914 mm)

2 CDVR33SC7 Direct Vent T E C H N I C A L S P E C I F I C AT I O N S BTU Input: 18,000 Max, 13,000 Min. (Nat) / 18,000 Max, 13,000 Min. (LP) Ignition System: Signature Command System (AC w/ battery back up) Gas Type: Natural Gas or Liquid Propane Gas Line: 18 (473 mm) Flex line w/ shut off FPT Flue Type: 4 x 7 Twist Lock, Flex Vent* Termination: Dedicated Rear Vent Horizontal Vent: Maximum 20 (508 mm) straight off rear of unit Low Voltage Wall Switch Wire: 15' (4.5 m) wire with wall switch and cover Design Certified: CSA C L E A R A N C E T O F L U E Horizontal: 3 (26 mm) Top, 1 (25 mm) Bottom and sides** Vertical: 1 (25 mm) on all sides C L E A R A N C E T O C O M B U S T I B L E S Fireplace: 0 Clearance to stand offs all sides Floor of unit to Ceiling: 72 (1.83 m) to Combustibles Firebox Opening to Wall: to Combustibles Hearth Requirement: 0 Clearance E F F I C I E N C Y D ATA Thermal Efficiency: Up to 80% Nat / 80% LP AFUE Efficiency: 61.2% Nat / 66.3% LP P4 Canada Efficiency: 57.6% Nat / 64.3% LP M A N T E L C L E A R A N C E S NOTE: The combustible area above the facing must not protrude more than 3/4 (19 mm) from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed here. 14 (356 mm) 11 (279 mm) 10 (254 mm) Top of Heat Exhaust Vent Side View Finish Wall Header Wall Standoff FP2285b Combustible Material Area *Simpson Dura-Vent, Selkirk Metalbestos and Metalfab are also approved for vent applications (requires adapter). **When vertical rise is 7-1/2 feet (2.29 m) or higher from base of unit, the horizontal vent clearance to combustibles is 1" (25 mm) all sides. FP2286 Side of Fireplace Opening 1 (25 mm) 1-1/2 (38 mm) 3-1/2 (89 mm) 4-1/2 (114 mm) 3 (76 mm) 45 Front View MADE IN U.S.A. HPBA Hearth, Patio & Barbecue Association To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. 12/10 ver.1

3 CDVR36SC7 and CDVT36SC7 Direct Vent 21-7/8 (556 mm) 10-15/16 (278 mm) Opening Depth 6-1/2 (165 mm) 1/2 (12.7 mm) 15-3/4 (400 mm) 15-1/4 (387 mm) 37-1/2 (953 mm) Opening Width Opening Height G L A S S V I E W I N G A R E A 29-1/16 W x 20-3/8 H (591 Square Inches) (738 mm x 518 mm) 1-1/4 (31.8 mm) 29-1/16 (738 mm) 20-3/8 (518 mm) 34-9/16 (878 mm) 39 (991 mm) S TA N D A R D F E AT U R E S Unitized black louver assembly Ember bed burner Ceramic Fiber logs Grate Junction box Nailing tabs for and 15/16 (23.8 mm) 32 (813 mm) 37-1/16 (941 mm) F I E L D I N S TA L L E D A C C E S S O R I E S Firebrick: Tavern Brown Curved Trim: Black Medium Trim Kit: Black Manual Blower and Cord (160cfm): FK-12 Thermostat Blower (160cfm): BLOT Signature Command Blower (160cfm): BLOTSC (requires purchase of SCSACM & TSFSC) Signature Command Remotes & Thermostats: RMSC, TSMSC, TSTSC, TSFSC, WT) Signature Command Accessories: A/C Accessory, Module and Command Center, Wall Mount Kits Conversion Kits: Natural Gas (CDV36CKNS), LP Gas (CDV36CKPS) Mesh Screen Glass Cover Wood Cabinet Surrounds Designer Facings (Current 400DVB trim, fronts and filigree panels will fit the CDV. Doors and door frames do not.) 2-3/8 (60 mm) 5-7/16 (138 mm) 37-1/16 (941 mm) 52-7/16 (1332 mm) 26-1/4 (667 mm) 25-1/4 (641 mm) 38- (981 mm) 37-1/16 (941 mm)

4 CDVR36SC7 and CDVT36SC7 Direct Vent T E C H N I C A L S P E C I F I C AT I O N S BTU Input: 18,000 Max, 15,000 Min. (Nat) / 18,000 Max, 15,000 Min. (LP) Ignition System: Signature Command System (AC w/ battery back up) Gas Type: Natural Gas or Liquid Propane Gas Line: 18 (473 mm) Flex line w/ shut off FPT Flue Type: 4 x 7 Twist Lock, Flex Vent* Termination: Dedicated Top or Rear Vent Min. Height Top Venting Before Elbow: 0 Horizontal Vent: Maximum 20 (508 mm) straight off rear of unit Low Voltage Wall Switch Wire: 15' (4.5 m) wire with wall switch and cover Design Certified: CSA C L E A R A N C E T O F L U E Horizontal: 3 (26 mm) Top, 1 (25 mm) bottom and sides** Vertical: 1 (25 mm) on all sides C L E A R A N C E T O C O M B U S T I B L E S Fireplace: 0 clearance to stand offs all sides Floor of unit to Ceiling: 72 (1.83 m) to combustibles Firebox Opening to Wall: to combustibles Hearth Requirement: 0 clearance M A N T E L C L E A R A N C E S NOTE: The combustible area above the facing must not protrude more than 3/4 (19 mm) from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed here. 11 (279 mm) 10 (254 mm) Top of Heat Exhaust Vent Side View Finish Wall Header Standoff FP2285b E F F I C I E N C Y D ATA CDVR CDVT Thermal Efficiency: Up to 80% Nat / 80% LP Up to 80% Nat / 80% LP AFUE Efficiency: 62% Nat / 66.4% LP N/A P4 Canada Efficiency: 49.7% Nat / 56.1% LP 47.6% Nat / 55.4% LP *Simpson Dura-Vent, Selkirk Metalbestos and Metalfab are also approved for vent applications (requires adapter). **When vertical rise is 7-1/2 feet (2.29 m) or higher from base of unit, the horizontal vent clearance to combustibles is 1" (25 mm) all sides. FP2286 Side of Fireplace Opening 1 (25 mm) 1-1/2 (38 mm) 3-1/2 (89 mm) 3 (76 mm) 4-1/2 (114 mm) Wall Combustible Material Area 45 Front View MADE IN U.S.A. HPBA Hearth, Patio & Barbecue Association To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. 12/10 ver.1

5 CDVR42SC7 and CDVT42SC7 Direct Vent 25-7/8 (657 mm) 12-15/16 (329 mm) Opening Depth 6-1/2 (165 mm) 1/2 (12.7 mm) 15-3/4 (400 mm) 15-1/4 (387 mm) 41-1/4 (1048 mm) Opening Width Opening Height G L A S S V I E W I N G A R E A 33-1/16 W x 20-3/8 H (672 Square Inches) (840 mm x 518 mm) 1-1/4 (31.8 mm) 33-1/16 (840 mm) 20-3/8 (518 mm) 34-9/16 (878 mm) 39 (991 mm) S TA N D A R D F E AT U R E S Unitized black louver assembly Ember bed burner Ceramic Fiber logs Grate Junction box Nailing tabs for and F I E L D I N S TA L L E D A C C E S S O R I E S Firebrick: Tavern Brown Curved Trim: Black Medium Trim Kit: Black Manual Blower and Cord (160cfm): FK-12 Thermostat Blower (160cfm): BLOT Signature Command Blower (160cfm): BLOTSC (requires purchase of SCSACM & TSFSC) Signature Command Remotes & Thermostats: RMSC, TSMSC, TSTSC, TSFSC, WT) Signature Command Accessories: A/C Accessory, Module and Command Center, Wall Mount Kits Conversion Kits: Natural Gas (CDV42CKNS), LP Gas (CDV42CKPS) Mesh Screen Glass Cover Wood Cabinet Surrounds (rear vent models) Designer Facings (Current 500DVB trim, fronts and filigree panels will fit the CDV. Doors and door frames do not.) 15/16 (23.8 mm) 2-3/8 (60 mm) 36 (914 mm) 41 (1041 mm) 5-7/16 (138 mm) 40 (1016 mm) 56-7/16 (1434 mm) 28-1/4 (718 mm) 38- (981 mm) 25-1/4 (641 mm) 40 (1016 mm)

6 CDVR42SC7 and CDVT42SC7 Direct Vent T E C H N I C A L S P E C I F I C AT I O N S BTU Input: 24,000 Max, 17,000 Min. (Nat) / 24,000 Max, 18,000 Min. (LP) Ignition System: Signature Command System (AC w/ battery back up) Gas Type: Natural Gas or Liquid Propane Gas Line: 18 (473 mm) Flex line w/ shut off FPT Flue Type: 4 x 7 Twist Lock, Flex Vent* Termination: Dedicated Top or Rear Vent Min. Height Top Venting Before Elbow: 0 Horizontal Vent: Maximum 20 (508 mm) straight off rear of unit Low Voltage Wall Switch Wire: 15' (4.5 m) wire with wall switch and cover Design Certified: CSA C L E A R A N C E T O F L U E Horizontal: 3 (26 mm) Top, 1 (25 mm) bottom and sides** Vertical: 1 (25 mm) on all sides M A N T E L C L E A R A N C E S NOTE: The combustible area above the facing must not protrude more than 3/4 (19 mm) from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed here. 9-1/2 (241 mm) 8-1/2 (216 mm) Finish Wall Header Standoff C L E A R A N C E T O C O M B U S T I B L E S Fireplace: 0 clearance to stand offs all sides Floor of unit to Ceiling: 72 (1.83 m) to combustibles Firebox Opening to Wall: to combustibles Hearth Requirement: 0 clearance Top of Heat Exhaust Vent Side View FP2285b E F F I C I E N C Y D ATA CDVR CDVT Thermal Efficiency: Up to 80% Nat / 80% LP Up to 80% Nat / 80% LP AFUE Efficiency: 64.2% Nat / 65.1% LP N/A P4 Canada Efficiency: 71% Nat / 72.3% LP 59.1% Nat / 67.6% LP *Simpson Dura-Vent, Selkirk Metalbestos and Metalfab are also approved for vent applications (requires adapter). **When vertical rise is 7-1/2 feet (2.29 m) or higher from base of unit, the horizontal vent clearance to combustibles is 1" (25 mm) all sides. FP2286 Side of Fireplace Opening 1 (25 mm) 1-1/2 (38 mm) 3-1/2 (89 mm) 3 (76 mm) 4-1/2 (114 mm) Wall Combustible Material Area 45 Front View MADE IN U.S.A. HPBA Hearth, Patio & Barbecue Association To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. 12/10 ver.1

7 CDVR47SC7 and CDVT47SC7 Direct Vent 31-7/8 (810 mm) 15-15/16 (405 mm) Opening Depth 6-1/2 (165 mm) 1/2 (12.7 mm) 15-3/4 (400 mm) 15-1/4 (387 mm) 47-1/4 (1200 mm) Opening Width Opening Height G L A S S V I E W I N G A R E A 39-1/16 W x 20-3/8 H (672 Square Inches) (992 mm x 518 mm) 1-1/4 (31.8 mm) 39-1/16 (992 mm) 20-3/8 (518 mm) 34-9/16 (878 mm) 39 (991 mm) S TA N D A R D F E AT U R E S Unitized black louver assembly Ember bed burner Ceramic Fiber logs Grate Junction box Nailing tabs for and F I E L D I N S TA L L E D A C C E S S O R I E S Firebrick: Tavern Brown Curved Trim: Black Medium Trim Kit: Black Manual Blower and Cord (160cfm): FK-12 Thermostat Blower (160cfm): BLOT Signature Command Blower (160cfm): BLOTSC (requires purchase of SCSACM & TSFSC) Signature Command Remotes & Thermostats: RMSC, TSMSC, TSTSC, TSFSC, WT) Signature Command Accessories: A/C Accessory, Module and Command Center, Wall Mount Kits Conversion Kits: Natural Gas (CDV42CKNS), LP Gas (CDV42CKPS) Mesh Screen Glass Cover Wood Cabinet Surrounds (rear vent models) Designer Facings (Current 600DVB trim, fronts and filigree panels will fit the CDV. Doors and door frames do not.) 15/16 (23.8 mm) 2-3/8 (60 mm) 42 (1067 mm) 47 (1194 mm) 5-7/16 (138 mm) 44-1/8 (1121 mm) 62-7/16 (1586 mm) 21-1/4 (794 mm) 38- (981 mm) 25-1/4 (641 mm) 44-1/8 (1121 mm)

8 CDVR47SC7 and CDVT47SC7 Direct Vent T E C H N I C A L S P E C I F I C AT I O N S BTU Input: 24,000 Max, 17,000 Min. (Nat) / 24,000 Max, 18,000 Min. (LP) Ignition System: Signature Command System (AC w/ battery back up) Gas Type: Natural Gas or Liquid Propane Gas Line: 18 (473 mm) Flex line w/ shut off FPT Flue Type: 4 x 7 Twist Lock, Flex Vent* Termination: Dedicated Top or Rear Vent Min. Height Top Venting Before Elbow: 0 Horizontal Vent: Maximum 20 (508 mm) straight off rear of unit Low Voltage Wall Switch Wire: 15' (4.5 m) wire with wall switch and cover Design Certified: CSA C L E A R A N C E T O F L U E Horizontal: 3 (26 mm) Top, 1 (25 mm) bottom and sides** Vertical: 1 (25 mm) on all sides C L E A R A N C E T O C O M B U S T I B L E S Fireplace: 0 clearance to stand offs all sides Floor of unit to Ceiling: 72 (1.83 m) to combustibles Firebox Opening to Wall: to combustibles Hearth Requirement: 0 clearance E F F I C I E N C Y D ATA CDVR CDVT Thermal Efficiency: Up to 80% Nat / 80% LP Up to 80% Nat / 80% LP AFUE Efficiency: N/A Nat / 63.2% LP N/A P4 Canada Efficiency: 69.6% Nat / 70.6% LP 56.6% Nat / 65.7% LP M A N T E L C L E A R A N C E S NOTE: The combustible area above the facing must not protrude more than 3/4 (19 mm) from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed here. Finish Wall 9-1/2 (241 mm) 8-1/2 (216 mm) Top of Heat Exhaust Vent Side View Header Wall Standoff FP2285b Combustible Material Area *Simpson Dura-Vent, Selkirk Metalbestos and Metalfab are also approved for vent applications (requires adapter). **When vertical rise is 7-1/2 feet (2.29 m) or higher from base of unit, the horizontal vent clearance to combustibles is 1" (25 mm) all sides. FP2286 Side of Fireplace Opening 1 (25 mm) 1-1/2 (38 mm) 3-1/2 (89 mm) 4-1/2 (114 mm) 3 (76 mm) 45 Front View MADE IN U.S.A. HPBA Hearth, Patio & Barbecue Association To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. 12/10 ver.1

Direct Vent Gas Fireplaces CAPTIVATING BEAUTY. INVITING WARMTH.

Direct Vent Gas Fireplaces CAPTIVATING BEAUTY. INVITING WARMTH. Direct Vent Gas Fireplaces CAPTIVATING BEAUTY. INVITING WARMTH. JUST YOUR STYLE. With a variety of options, ranging from specialty and contemporary to more traditional styles, you re sure to discover the

More information

Direct Vent Gas Fireplaces WELCOME GREAT STYLE INTO YOUR HOME

Direct Vent Gas Fireplaces WELCOME GREAT STYLE INTO YOUR HOME Direct Vent Gas Fireplaces WELCOME GREAT STYLE INTO YOUR HOME MAKE A STYLISH STATEMENT. With a variety of options, ranging from specialty and contemporary to more traditional styles, you re sure to find

More information

Gas Vent Free Fireboxes. Luxury and Versatility for Your Home

Gas Vent Free Fireboxes. Luxury and Versatility for Your Home Gas Vent Free Fireboxes Luxury and Versatility for Your Home ENJOY THE EXTRA FREEDOM OF A VENT FREE FIREPLACE Majestic, a leader in vent free hearth appliances, offers one of the most diverse lineups available,

More information

GAS FIREPLACE INSERTS

GAS FIREPLACE INSERTS GAS FIREPLACE INSERTS Fireplace Insert Modern Surround, Black Enameled Liner, and Glass Fireplace Insert Modern Surround, Ledgestone Liner, and Coal Fireplace Insert w/trimmable Panel, Brick Liner, and

More information

CNXT4236IT, CNXT4236IH

CNXT4236IT, CNXT4236IH Caliber 36 Gas Fireplace - DV Log Set Assembly 7 3 6 4 8 1 5 2 9 10 11 14 13 12 16 15 17 18 19 28 27 20 21 26 25 22 23 (Valve Assy.) 24 Part number list on following page. 06/17 Log/Grate Assembly 4047-007

More information

Vermont Castings. MSRP Price Book Table of Contents. Vermont Castings Stove - Wood

Vermont Castings. MSRP Price Book Table of Contents. Vermont Castings Stove - Wood Vermont Castings MSRP Price Book Table of Contents Vermont Castings Stove - Wood Aspen Page 2 Defiant Flexburn Page 3 Encore Flexburn Page 5 Intrepid II Page 7 Stove - Gas Intrepid DV Page 8 Radiance DV

More information

NOVUS. Direct Vent & B-Vent Series

NOVUS. Direct Vent & B-Vent Series NOVUS Direct Vent & -Vent Series Direct Vent & -Vent Series FRMING & CLERNCE DIMENSIONS Framing Dimensions Product Dimensions Model ND/N3630 ND/N3933 ND/N4236 ND/N4842 35" 38" 41" 47" 30" 33" 36" 42" C

More information

WOOD F I R E P L A C E I N S E R T S

WOOD F I R E P L A C E I N S E R T S d e s i g n e d t o h e a t. b u i l t t o l a s t. WOOD F I R E P L A C E I N S E R T S THE CABELLO FLUSH- FACE INSERT THE CABELLO Design Features Fireplace Details The Cabello is the newest edition to

More information

VENT FREE FIREPLACES, STOVES & GAS LOGS napoleonfireplaces.com

VENT FREE FIREPLACES, STOVES & GAS LOGS napoleonfireplaces.com VENT FREE FIREPLACES, STOVES & GAS LOGS napoleonfireplaces.com All the features of a direct vent fireplace... without the venting Torch - Plazmafire - Plazmafire - GVFT8...4-5 WHVF24...6-7 WHVF31...6-7

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

VENT FREE FIREPLACES, STOVES & GAS LOG SETS. napoleonfireplaces.com

VENT FREE FIREPLACES, STOVES & GAS LOG SETS. napoleonfireplaces.com VENT FREE FIREPLACES, STOVES & GAS LOG SETS napoleonfireplaces.com All the features of a direct vent fireplace... without the venting Torch - Plazmafire - Plazmafire - GVFT8...4-5 WHVF24...6-7 WHVF31...6-7

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

Spare Parts Information List

Spare Parts Information List REGENCY Spare Parts Information List Effective 1st September 2010 ALL PRICES EXCLUDE GST AIR GROUP AUSTRALIA 28/30 DIVISION STREET WELSHPOOL WA 6106 Telephone (08) 9350 2200 Facsimile (08) 9353 4225 www.airgroup.com.au

More information

DV Power Vent System Model 7THPDVS

DV Power Vent System Model 7THPDVS Model 7THPDS WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY WHAT TO DO IF YOU

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

VENT FREE FIREPLACES, STOVES & GAS LOGS napoleonfireplaces.com

VENT FREE FIREPLACES, STOVES & GAS LOGS napoleonfireplaces.com VENT FREE FIREPLACES, STOVES & GAS LOGS napoleonfireplaces.com All the features of a direct vent fireplace... without the venting Torch - Plazmafire - Plazmafire - GVFT8...4-5 WHVF24...6-7 WHVF31...6-7

More information

AF90. AF90 Gas Furnace High Efficiency. Features

AF90.   AF90 Gas Furnace High Efficiency. Features AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

Wood Burning Fireplaces BEAUTY BY DESIGN

Wood Burning Fireplaces BEAUTY BY DESIGN Wood Burning Fireplaces BEAUTY BY DESIGN 2 ROYALTON SERIES Royalton BE42 shown with Traditional Firebrick IMAGINE THE FIREPLACE OF YOUR DREAMS. Nothing beats the crackle and comfort of a fire and now with

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

Pellet Stoves and Inserts

Pellet Stoves and Inserts Pellet Stoves and Inserts MINI SMALL PE LLET STOVE Mini Freestanding Pellet Stove Stove Details Automatic controls Run Quiet system 30,000 BTU 18 Large viewing area (130 sq. in.) Large ash pan Comes with

More information

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH) 1 SEASONAL EFFICIENCY 2 LARGEST REC A/C 3 FUEL

More information

TOFINO SERIES GAS INSERTS. i20 i30 i40 ELEGANT VERSATILE EFFICIENT

TOFINO SERIES GAS INSERTS. i20 i30 i40 ELEGANT VERSATILE EFFICIENT TOFINO SERIES GAS INSERTS i20 i30 i40 ELEGANT VERSATILE EFFICIENT THE NEXT GENERATION OF GAS INSERTS THREE DISTINCT FIREBOX SIZES Transform your existing fireplace and come home to warmth and style - introducing

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

Level 2 title. Level 1 title. Gas Inserts

Level 2 title. Level 1 title. Gas Inserts Ask your authorized Jøtul Group Dealer about our full line of cast iron wood and gas stoves, inserts and fireplaces. Level 1 title Level 2 title A Jøtul Group Company Jøtul AS P.o. box 1411 Jøtul 1602

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. CMC1-50D36 (DV3) CMC1-75D36 (DV3) HEAT INPUT RATE (BTUH) 50,000 75,000 OUTPUT (BTUH)

More information

OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT

OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE INSTRUCTIONS These instructions are supplementary to the Installation and Operating Instructions supplied with the fi replace and should be

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

GreenStart Igniter for Inserts: Installation Instructions (SKU )

GreenStart Igniter for Inserts: Installation Instructions (SKU ) Compatibility Flush Wood Plus Rectangular SN #1401-10265 or greater Flush Wood Plus Arch SN #1401-10106 or greater Flush Wood Plus Cape Cod Large Flush Wood Insert NOTE: Use the firebrick and igniter housing

More information

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

GKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

GKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h Series up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Upflow Multi- Position, Multi-Speed Gas Furnace Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas

More information

IB Series Conversion Kits

IB Series Conversion Kits Escea_Spare_Parts_Price_List_June_2013.xlsx Page 1 Product Image Product Product Description Code Weight (KG) Cubic (M3) Width (cm) Length (cm) Depth (cm) IB Series Conversion Kits 811220 811221 IB850

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

Crestfire Electric Series. Inserts and Fireplaces

Crestfire Electric Series. Inserts and Fireplaces Crestfire Electric Series Inserts and Fireplaces A Anywhere any style & B A. Crestfire 750E-B shown with Mount Vernon mantel, black granite and brushed nickel Essence operable doors with Waverly interchangeable

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

CALAIS/GRENADA MILAN Natural Gas/LPG

CALAIS/GRENADA MILAN Natural Gas/LPG Issue B January 2004 REF # FPI 2107 INBUILT GAS FIRES CALAIS/GRENADA MILAN Natural Gas/LPG (New Zealand/Australia) NZ AUST Part CALAIS / P36NG3-MN P36NG3-MA Numbers Conversion Kit - Natural Gas to LPG

More information

G95V Series Gas-Fired 95% 2-Stage High Efficiency (Condensing) Multi-Positional Furnace w/ ECM Circulator

G95V Series Gas-Fired 95% 2-Stage High Efficiency (Condensing) Multi-Positional Furnace w/ ECM Circulator 5/23/07 G95V Service Parts 1 Key No. Description Cabinet Group Top Panel Left Side Panel Assembly Right Side Panel Assembly Rear Panel Blower Division Panel Assembly,,, Base Panel,, Upper Front Door Panel,

More information

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE / 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY

More information

Lennox HP Quick Reference Guide

Lennox HP Quick Reference Guide Gas Fireplaces SS = Steady State Efficiency Framing Framing Framing Model BTU's Low BTU's Efficiency Height " Width" Depth" H" View W" View Venting Pwr Vent Ravelle 30 30,000 20,000 82-86% SS 41" 41 1/2"

More information

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 92% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

N9MPD Product Specifications

N9MPD Product Specifications Single Stage Furnace Multiposition FLEXIBILITY Dual certified venting (1 or 2 pipes) Direct Vent furnace 40 (1016mm) high with wider cabinets, for ease of installation Factory shipped as natural gas, with

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

KOMFORT ZONE KIT. For use with the Callway-50 #CLW-50 Direct Vent Gas Fireplace

KOMFORT ZONE KIT. For use with the Callway-50 #CLW-50 Direct Vent Gas Fireplace KOMFORT ZONE KIT For use with the Callway-50 #CLW-50 Direct Vent Gas Fireplace HUSSONG MANUFACTURING CO., INC. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

More information

ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION

ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION RESIDENTIAL AND COMMERCIAL GAS REPLACEMENT PARTS LIST ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION EFR160T120*(EN,SX) EF(60,100)T(125-300)(E*N)(*X)(A)2 (Serial Number GB13006174 and AFTER) Includes

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h / ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11

More information

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic

More information

BEYOND. EXPECTATIONS High quality and unique design for your comfort Version

BEYOND.  EXPECTATIONS High quality and unique design for your comfort Version fire www.osburn-mfg.com EXPECTATIONS High quality and unique design for your comfort 2013 Version 1 fire A single word that captures our philosophy and commitment at Osburn. This is our source of inspiration.

More information

1080 CF Valve Replacement Instructions

1080 CF Valve Replacement Instructions Overview This kit includes the newer American Flame gas control valve designed specifically for the 1080 CF gas fireplace. If you have a 1080 CF fireplace, and you are uncertain as to whether this kit

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

FIREPLACE INSERT INTERIOR PARTS MODEL #'S: 0044, 0046, 1271 & 1272 FEATURES: 0044 WOOD INSERT WITH NO BRASS TRIM 0046 WOOD INSERT WITH BRASS TRIM 1271 COAL INSERT WITH NO BRASS TRIM 1272 COAL INSERT WITH

More information

The Breckenridge Series Vent-Free Gas Fireboxes Deluxe, Premium, and Select

The Breckenridge Series Vent-Free Gas Fireboxes Deluxe, Premium, and Select The Breckenridge Series Vent-Free Gas Fireboxes Deluxe, Premium, and Select Breckenridge Premium 36 Firebox with Slope Glaze Burner, Charred Oak Log Set, Mission Louvers and Doors installed in an Oak Standard

More information

AKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE

AKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Single-Stage Multi-Speed Gas Furnace up to 92.1% AFUE Standard Features Stainless-steel secondary heat exchanger Single-stage gas valve Durable Silicon Carbide ignitor

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency

More information

Wood Multi-Sided Series. Woodburning Fireplaces

Wood Multi-Sided Series. Woodburning Fireplaces Wood Multi-Sided Series POSSIBILITIES (shown with DM doors) ST36D/ST42A (ST42A shown) CL36D/CR36D (CL36D shown with DP doors) 800-927-6841 See-Through Fireplaces PRODUCT & FRAMING DIMENSIONS This information

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

SEALED WITH GLASS OR OPEN NO GLASS

SEALED WITH GLASS OR OPEN NO GLASS L I N E A R SEALED WITH GLASS OR OPEN NO GLASS SINGLE-SIDED SEE-THROUGH INDOOR/OUTDOOR 19672 172nd St, Big Lake, MN (888) 317-6499 (763) 263-3156 info@acucraft.com ABOUT ACUCRAFT For over 35 years, we

More information

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303) TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced

More information

Figure 1-1(d) Tft Installation Kit

Figure 1-1(d) Tft Installation Kit TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending

More information

F8MTL. Product Specifications

F8MTL. Product Specifications 80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115

More information

The Breckenridge Series Vent-Free Gas Fireboxes Deluxe, Premium, and Select

The Breckenridge Series Vent-Free Gas Fireboxes Deluxe, Premium, and Select The Breckenridge Series Vent-Free Gas Fireboxes Deluxe, Premium, and Select Breckenridge Premium 36 Firebox with Charred Oak Log Set, Mission Louvers and Doors installed in an Oak Standard Mantel. White

More information

P-SERIES pellet stoves & inserts

P-SERIES pellet stoves & inserts P-SERIES pellet stoves & inserts Built to a standard not a price Sealed hopper Quiet, variable-speed blower 3 Air Grille Accent options Flame reactive mirrored glass with large viewing area Hidden Control

More information

OPTIONAL HORIZONTAL VARIABLE DEPTH POWER VENT KIT

OPTIONAL HORIZONTAL VARIABLE DEPTH POWER VENT KIT INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

KG7S (A and K Series)

KG7S (A and K Series) TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed

More information

Ultra High Efficiency Models With Direct Spark Ignition

Ultra High Efficiency Models With Direct Spark Ignition RESIDENTIAL AND COMMERCIAL REPLACEMENT PARTS LIST Ultra High Efficiency Models With Direct Spark Ignition EFR160T120*(EN,SX) EF(60,100)T(125-300)(E*N)(*X)(A)2 (Serial Number GB13006174 and AFTER) Includes

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

HIGH CAPACITY POWER VENT KIT

HIGH CAPACITY POWER VENT KIT IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE INSTRUCTIONS These instructions are supplementary to the Installation and Operating Instructions supplied with the fi replace and should be

More information

CALAIS/ MILAN/BARCELONA Natural Gas/LPG

CALAIS/ MILAN/BARCELONA Natural Gas/LPG Issue A February 2002 IPL Part # FPI 2107 INBUILT GAS FIRES CALAIS/ MILAN/ Natural Gas/LPG (New Zealand/Australia) Louvres NZ AUST Part Calais Black Natural Gas FPI2107 Numbers LPG FPI2108 Calais Brass

More information

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

GKS9 Series. Upflow Multi-Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

GKS9 Series. Upflow Multi-Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h Series Upflow Multi-Position, Multi-Speed Gas Furnace up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Standard Features Heavy-duty aluminized-steel, dual-diameter, tubular heat exchanger Stainless-steel

More information

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Product Data Upflow/ Horizontal Left/Right, Downflow Two Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2B040U3PSBB S9V2B060U3PSBB S9V2B060U4PSBB S9V2B080U3PSBB

More information

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP Space Heaters This Parts Listing has been compiled for your benefit. You can be assured your space heater was constructed and designed with quality and performance

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

Stellar Hearth Products

Stellar Hearth Products CML-58 Contemporary Gas Fireplace Price List - Effective October 2015 CML - Build Your Own Interior CML-58 with optional glass media CML-58 NG, Black Interior Only (No Glass Log Set, Mirrored Liner or

More information

Commercial Dryers. Parts. Metered and Nonmetered. Refer to Page 3 for Model Numbers. DRY721C_515202

Commercial Dryers. Parts. Metered and Nonmetered. Refer to Page 3 for Model Numbers.  DRY721C_515202 Commercial Dryers Metered and Nonmetered Refer to Page 3 for Model Numbers Parts DRY721C_515202 www.alliancelaundry.com Part No. 515202R1 April 2015 Table of Contents Title Page Parts Ordering Information...

More information

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)

More information

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21053-001 Rev. A (4/00) DESCRIPTION These high efficiency, dedicated downflow compact units employ induced combustion, reliable hot surface ignition and high heat transfer tubular heat exchangers.

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

VECTOR AND LUXURIA LINEAR napoleonfireplaces.com SERIES GAS FIREPLACES

VECTOR AND LUXURIA LINEAR napoleonfireplaces.com SERIES GAS FIREPLACES VECTOR AND LUXURIA LINEAR napoleonfireplaces.com SERIES GAS FIREPLACES Vector and Luxuria Linear Gas Fireplaces. Limitless Possibilities. Napoleon introduces the most versatile series of linear gas fireplaces,

More information

PARTS AND SERVICE MANUAL

PARTS AND SERVICE MANUAL PARTS AND SERVICE MANUAL FOR THE 23 INSERT FIREPLACE MODEL NUMBER: DFI2309 TABLE OF CONTENTS OPERATION PAGE 1 PARTS DRAWING PAGE 3 PARTS LIST PAGE 4 WIRING DIAGRAM PAGE 5 LIGHT BULB REPLACEMENT PAGE 6

More information

NOTICE DO NOT DISCARD THIS MANUAL. Read, understand and follow these instructions for safe installation and operation.

NOTICE DO NOT DISCARD THIS MANUAL. Read, understand and follow these instructions for safe installation and operation. Owner s Manual Installation and Operation MODELS: ST-HVBI-AUB ST-HVBILP-AUB SAI Global Ref No GSCS20165 AS 4553:2008 Important operating and maintenance instructions included. NOTICE DO NOT DISCARD THIS

More information

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE / Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter

More information