N9MPD Product Specifications
|
|
- Laureen Jefferson
- 5 years ago
- Views:
Transcription
1 Single Stage Furnace Multiposition FLEXIBILITY Dual certified venting (1 or 2 pipes) Direct Vent furnace 40 (1016mm) high with wider cabinets, for ease of installation Factory shipped as natural gas, with Propane Gas conversion kits available Four position upflow/downflow/horizontal installation Vent pipe can be run horizontally or vertically Internal condensate drain system SERVICE Self diagnostics Entire blower assembly mounted on rails COMFORT Adjustable timed blower Off delay 24 and 115 VAC humidifier terminal Electronic air cleaner terminal EFFICIENCY 92.1% AFUE efficiency range Single stage gas valve operation Single stage integrated control Multispeed, prelubricated PSC blower motors Induced draft blower In shot burners California NOx approved QUALITY Stainless steel secondary heat exchanger High temperature limit control prevents overheating Direct ignition with Silicon Nitride ignitor Flame roll out sensors standard Solid doors WARRANTY * 20 year heat exchanger limited warranty 5 year parts limited warranty With timely registration, an additional 5 year parts limited warranty * Applies to original purchaser/homeowner, some limitations may apply. See warranty certificate for complete details. N9MPD Product Specifications Illustrations and photographs are only representative. Some product models may vary.! WARNING This furnace is not designed for use in mobile homes, trailers, or recreational vehicles. Such use could result in property damage and/or death. THIS MODEL 92.1 As an Energy Star Partner, International Comfort Products has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Ask your contractor for details or visit UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Model Dimensions H x W x D Input Efficiency Cooling Capacity Shipping Wt. Number Inches Millimeters (MBTUH) in wc (125 Pa) Lbs Kg N9MPD040F08A 40 x x x 486 x TON N9MPD050F12A 40 x x x 486 x TON N9MPD060F12A 40 x x x 486 x TON N9MPD075F12A 40 x x x 486 x TON N9MPD080J16A 40 x 22 3 / 4 x x 578 x TON N9MPD100J14A 40 x 22 3 / 4 x x 578 x TON N9MPD100J20A 40 x 22 3 / 4 x x 578 x TON N9MPD125L20A 40 x 2 x x 622 x TON Feb 2009
2 FURNACE SPECIFICATIONS Model Number (NAT. GAS) N9MPD040F08 N9MPD050F12 N9MPD060F12 N9MPD075F12 N9MPD080J16 N9MPD100J14 N9MPD100J20 N9MPD125L20 INPUT (btuh) 40,000 50,000 60,000 75,000 80, , , ,000 HTG. CAP. (btuh) 37,000 46,000 55,000 70,000 75,000 93,000 93, ,000 AFUE % (ICS) ALTERNATE INPUT BTUH NA 40,000 NA 60,000 NA 80,000 80, ,00 ALTERNATE OUTPUT BTUH NA 36,400 NA 54,000 NA 72,000 72,000 90,500 NOx (Ng/J) <40 TEMP. RISE DEGREES ( o F/ o C) 35-65/ / / / / / / /22-38 VOLTS/HZ/PH 115/1/60 MIN./MAX. VOLTAGE 104/127 RATING PLATE AMPS TRANSFORMER (V.A.) 40 GAS PIPE SIZE (in.) 1/2 VENT SIZE in(mm) * 2 or 3 (50.8 or 76.2) OD 3 (76.2) OD VENT CONNECTION in(mm) 2 (50.8) OD COOLING CAP HIGH ALT. PRESSURE SWITCH FILTER SIZE required - in(mm) (qty) DIMENSIONS H x W x D - in(mm) 40 x x 29 (1016 x 486 x 737) 16 x 25 x 1 (406 x 635 x 25) (1) 40 x 22 3 / 4 x 29 (1016 x 578 x 737) 16 x 25 x 1 (2) (406 x 635 x 25) (2) 40 x 2 x 29 (1016x622x737) WEIGHT Lbs(Kg) 150(68) 150(68) 153(69) 153(69) 172(78) 172(78) 180(82) 193(88) * Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions MODEL NUMBER IDENTIFICATION GUIDE N 9 M P D 0 75 F 1 2 A # Brand Identifier Engineering Rev. N = Non Brand Specific (Generic) Denotes minor change Model Efficiency Marketing Digit 8 = Non Condensing, 80+% Gas Furnace Denotes major change 9 = Condensing, 90+% Gas Furnace Cooling Airflow Installation Configuration 08 = 800 CFM UP = Upflow DN = Downflow UH = Upflow/Horizontal 12 = 1200 CFM HZ = Horizontal DH = Downflow/Horizontal 14 = 1400 CFM MP = Multiposition, Up/Down/Horizontal 16 = 1600 CFM Major Design Feature 20 = 2000 CFM 1 = One (Single) Pipe N = Single Stage Cabinet Width 2 = Two Pipe P = PVC Vent B = 15.5 Wide J = 22.8 Wide D = 1 or 2 Pipe T = Two Stage F = 19.1 Wide L = 24.5 Wide L = Low NOx V = Variable Input X = Extra Efficiency (Nominal MBTUH) 2
3 DIMENSIONS F AIR INTAKE 2 1 / 4 (57.2) 13 1 / 4 (336.6) TOP LEFT SIDE TRAP (KO) (COUNTERFLOW) VENT E AIR INTAKE (KO) (ALTERNATE) 4 13 / 16 TRAP (KO) (122.2) UPFLOW/HORIZONTAL THERMOSTAT (KO) GAS VENT H G 6 11 / 16 ELECTRICAL (177.5) 1 1 / 4 (32) 1 1 / 16 (27) / 16 (347.7) / (804.9) / 8 (34.9) 29 7 / 8 (758.8) / 4 (177.8) (730.3) 24 1 / 16 (611.2) 17 5 / / 16 (439.7) (503.2) 1 11 / 16 (42.9) A B FRONT MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS REAR 0 FRONT (combustion air openings in furnace and in structure) 3 (76.2) Required For Service *24 (609.6) ALL SIDES Of SUPPLY PLENUM 1 (25.4) SIDES 0 VENT 0 TOP OF FURNACE 1 (25.4) *30 (762mm) clearance recommended for furnace removal. Horizontal position: Line contact is permissible only between lines formed by intersections of top and two sides of furnace jacket, and building joists, studs or framing. NOTE: Evaporator A coil drain pan dimensions may vary from furnace duct opening size. Always consult evaporator specifications for duct size requirements. Furnace is designed for bottom return or side return. Return air through back of furnace is NOT allowed / / (549.3) 8 (47.6) 24 (609.6) 4 7 / 8 (123.8) 1 1 / 4 (31.7) D C Unit Capacity N9MPD040F08 N9MPD050F12 N9MPD060F12 N9MPD075F12 N9MPD080J14 N9MPD100J20 N9MPD125L20 BOTTOM ALL DIMENSIONS IN IN(MM) 1 in = 25.4 mm 23 1 / / 8 (587.4) (98.4) 2 3 / 8 (60) 1 1 / 16 (27) Cabinet Bottom Top GAS A B C D E F G H 22 3 / 4 (578) 22 3 / 4 (578) 2 (622) 21 1 / 4 (540) 21 1 / 4 (540) 23 (584) 1 15 / 16 (49) 1 15 / 16 (49) 7 / 16 (11) 18 3 / 4 (476) 18 3 / 4 (476) 23 (584) 2 5 / 8 (67) 2 5 / 8 (67) 2 1 / 4 (57) 11 3 / 8 (289) 11 3 / 8 (289) 12 1 / 4 (311) 1 3 / 16 (30) 2 7 / 8 (73) 4 13 / 16 (122) 1 11 / (43) / 8 (759) 27 3 / / (691) 16 (251) 21 5 / 8 (549) / / 16 (856) (440) 1 11 / 16 (43) 4 5 / 16 (110) 7 (178) 28 1 / 2 3 / (724) 18 1 / 2 (470) 4 (19) TYP. RIGHT SIDE TRAP (COUNTERFLOW) ELECTRICAL (KO) AIR INTAKE (KO) (ALTERNATE) VENT (KO) TRAP (KO) UPFLOW/HORIZONTAL THERMOSTAT 2 1 / 4 (57) 19 1 / 4 (489) (KO) 40 (1016) 4 7 / 8 (124) 21 5 / 8 (549) 24 (610) 1 7 / 8 (48) KO = KnockOut Drawing is representative, but some models may vary 3
4 BLOWER PERFORMANCE in(mm) Model NO. NATURAL GAS (NOTE) N9MPD040F08 N9MPD050F12 N9MPD060F12 N9MPD075F12 N9MPD080J16 N9MPD100J14 N9MPD100J20 (2)(3)(5) N9MPD125L20 (2)(5) BLOWER SIZE - D x W 11 x 8 (279 x 203) 11 x 10 (279 x 254) MOTOR H.P. (TYPE) 1 / 4 PSC 1 / 2 PSC 1 / 2 PSC 1 / 2 PSC 1 / 2 PSC 1 / 2 PSC 3 / 4 PSC 3 / 4 PSC MOTOR SPEEDS AIRFLOW DATA N9MPD040F08 N9MPD075F12 * Denotes Brand N9MPD050F12 * Denotes Brand N9MPD080J16 * Denote Brand N9MPD060F12 N9MPD100J14 * Denotes Brand NOTE: (1) Data Based on Bottom Only or One Side return. (2) Data Based on Both Sides or Bottom plus One Side. (3) 100J20 Reduce airflow by 5% if Bottom Only return. (4) 125J20 Reduce airflow by 5% if Bottom Only return. (5) Gray area is above maximum temperature rise range. MAX CFM s for Factory Washable Filters Filter Size (in/mm) CFM L/s 14 X 25 / 356 x X 25 / 406 x X 25 / 508 x # CFM Cubic Feet Per Minute (M/s Meters per Second) airflow. Filter required for each return air inlet. 24 X 25 / 610 x Airflow perfomance includes 1 (25.4mm) washable [600 FPM (3.0 Max CFM based on 600 FPM (3.0 M/s) M/s) max] filter media. NOTE: Disposable filters are typically rated at 300 FPM (1.5 m/s). These filters only allow half the airflow when compared to 600 FPM (3.0 M/s) filters. EXAMPLE (approx.): 20in X 600 FPM = FPM = 1000 CFM 508mm x 3.0 M/s = M/s = 472 L/s 4
5 AIRFLOW DATA (continued) N9MPD100J20 * Denotes Brand N9MPD125L20 (2)(5) * Denotes Brand NOTE: (1) Data Based on Bottom Only or One Side return. (2) Data Based on Both Sides or Bottom plus One Side. (3) 100J20 Reduce airflow by 5% if Bottom Only return. (4) 125J20 Reduce airflow by 5% if Bottom Only return. (5) Gray area is above maximum temperature rise range. MAX CFM s for Factory Washable Filters Filter Size (in/mm) CFM L/s 14 X 25 / 356 x X 25 / 406 x X 25 / 508 x # CFM Cubic Feet Per Minute (M/s Meters per Second) airflow. Filter required for each return air inlet. 24 X 25 / 610 x Airflow perfomance includes 1 (25.4mm) washable [600 FPM (3.0 Max CFM based on 600 FPM (3.0 M/s) M/s) max] filter media. NOTE: Disposable filters are typically rated at 300 FPM (1.5 m/s). These filters only allow half the airflow when compared to 600 FPM (3.0 M/s) filters. EXAMPLE (approx.): 20in X 600 FPM = FPM = 1000 CFM 508mm x 3.0 M/s = M/s = 472 L/s 5
6 ACCESSORIES Model Number Description Used With Models NAHA004WK Twinning Kit Allows operation of two identical size model furnaces. All N9MPD Furnaces NAHA001LP ( ** ) NAHA001NG ( **) NAHA003LP ( ** ) NAHA004NG ( **) Gas Conversion Kits Natural gas to Propane conversion Kit. Allows field conversion to Propane gas. Gas Conversion Kits Propane to natural gas conversion kit. Allows field conversion to natural gas. Gas Conversion Kits Natural gas to Propane conversion Kit. Allows field conversion to Propane gas for 80k BTUh and Alternate input models. Gas Conversion Kits Propane to natural gas conversion kit. Allows field conversion to Natural gas for 80k BTUh and Alternate input models. N9MPD050, 075, 100, 125 N9MPD050, 075, 100, 125 N9MPD040/060/080 and Alternate Input Models N9MPD040/060/080 and Alternate Input Models NAHA001AL Alternate Input Kit (Nat Gas). Derates input by 20% N9MPD050, 075, 100, 125 NAHA002AL Alternate Input Kit (Propane Gas). Derates input by 20% N9MPD050, 075, 100, 125 NAHA001FF Filter Kits External filter frame. 16 x 25 (406mm x 635mm) Side Return (All Furnaces) Bottom Return (All F NAHA001FP External filter frame. 16 x 25 (406mm x 635mm) Bulk Pack Kit Qty 10 Furnaces under 1600 CFM) NAHA002FF NAHA002FP NAHA001TK NAHA001NK (612833**) Filter Kits Bottom return filter frame kit 20 x 25 (508mm x 635mm) Bottom return filter frame kit 20 x 25 (508mm x 635mm) Bulk Pack Kit Qty 10 Duct Standoff Filter Kit. To adapt 20 x 25 (508mm x 635mm) filter for single side return. Condensate neutralizer kit for condensing gas furnaces (All J 22 3 / 4 Furnaces) Side Return (All single return applications with 1600 CFM or greater) Bottom Return (All F Furnaces under 1600 CFM) All N9MPD Furnaces If Required NAHH002SB Combustible Floor Subbase Furnace ONLY: All 19 1 / 4 wide furnace N9MPD040, 050, 060, 075 NAHH003SB Combustible Floor Subbase Furnace ONLY: All 22 3 / 4 wide furnace N9MPD080, 100 NAHH010SB Combustible Floor Subbase Furnace ONLY: All 2 wide furnace N9MPD125 NAHH005SB NAHH006SB Subbase Furnace w/19 1 / 4 cased coil Subbase Furnace w/22 3 / 4 cased coil N9MPD040, 050, 060, 075 Counterflow furnace w/19 1 / 4 cased coil N9MPD080, 100 Counterflow furnace w/22 3 / 4 cased coil NAHH009SB Subbase Furnace w/2 cased coil N9MPD125 NAHA001CV ( **) NAHA002CV 3 (76.2mm) Concentric vent kit allows single wall penetration for 2 pipe direct vent applications (90+). Conversion: 1ft =.305m 2 (50.8mm) Concentric vent kit allows single wall penetration for 2 pipe direct vent applications (90+). Conversion: 1ft =.305m N9MPD040/050/060/075/080 (65 & (4) 90 elbows) N9MPD100 (35 or 65 & (4) 90 elbows) N9MPD125 (35 & (4) 90 elbows) N9MPD040/050/060/075/080 (35 & (4) 90 elbows) NAHA001CA Coil Adapter for Downflow Furnaces All Downflow Models ** High Altitude Pressure Switch Kit (2 Pressure Switches) N9MPD040F08 & 060F ** High Altitude Pressure Switch Kit (1 Pressure Switch) N9MPD050F12, 075F12 & 100J14/J ** High Altitude Pressure Switch Kit (1 Pressure Switch) N9MPD ** High Altitude Pressure Switch Kit (2 Pressure Switches) N9MPD125 NAHA002LV Long Vent Kit N9MPD100J14/100J20 NAHA003LV High Altitude Long Vent Kit N9MPD100J14/100J20 To replace Warning Labels, Operating Instructions & NAHA002WL Wiring Labels on Blower Door when needed ** Must be ordered from Service Parts N9MPD International Comfort Products, LLC Lewisburg, TN U.S.A. 6
UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)
C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE
COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationG8MVL. Product Specifications
80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity CFM in. w.c. (125 Pa)
95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationUp to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL
N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved
More informationCooling Capacity CFM in. w.c. (125 Pa)
95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationCooling Capacity CFM in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationN9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More informationWFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty
95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More informationWFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty
92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More informationTSTAT0101SC Recommended (sold separately)
Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation
More informationF8MTL. Product Specifications
80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115
More informationWFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN
92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationWFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. F verification of certification f individual products, go to www.ahridirecty.g.
More information96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe
More information95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe
More informationGUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas
More information95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger
Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized
More informationA951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN
A951E PRODUCT SPECIFICATIONS SINGLE STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A951E-100 (10/2018) CONTROLS Single stage gas valve Durable silicon nitride ignitor Self diagnostics saves
More information95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized
More informationAF90. AF90 Gas Furnace High Efficiency. Features
AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty
More informationGF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)
FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces
More informationA962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN
A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains
More informationFG7T (E and N Series)
TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency
More informationKG7T (E and N Series)
TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas
More information95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS
A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless
More information92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING
92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped
More informationA95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS
Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for
More informationDUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH
FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL
More informationFG7S (C and L Series)
TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000
More information95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES
95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)
More informationOLR Product Specifications
OLR Product Specifications LO BOY OIL FURNACE C Illustrations and photographs are only representative. Some product models may vary. US 85.0 to 86.8 ONLY applies to applications in Canada where the furnace
More informationUpflow, Upflow / Horizontal, Counterflow
, / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless
More informationKG7T (C and L Series)
TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency
More informationTECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh
More informationRheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More information93% Gas Furnaces Single Stage
Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped
More informationVG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input
TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow
More informationGMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 92% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationKG7T (C and L Series)
TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency
More informationGMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationUpflow, Upflow / Horizontal, Counterflow / Horizontal
Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long
More informationTable of Contents GF801U Series
FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed
More informationAMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h
/ ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11
More information80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor
80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped
More informationMulti-Position, Multi-Speed Gas Furnaces
Heating Input: 40,000 140,000 BTU/h / Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve control technology allows installer to
More informationTECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationRheem Value Series Upflow/Horizontal Gas Furnace
THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%
More informationTECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationGMS9/GCS9 SERIES 93% AFUE
/ SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel
More informationFG7T (A and K Series)
TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency
More informationAMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h
Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic
More information80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES
FORM NO. G66-478 REV. 1 Supersedes Form No. G66-478 Rev. 0 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing line of upflow/horizontal gas furnaces are designed for utility rooms, closets,
More informationKG7S (A and K Series)
TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed
More informationDM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h
/ Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11
More informationTECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.
TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose
More informationTECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.
036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units
More informationRheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces
THIS MODEL 78% 82% 88% 92.0% 97% Air Gas Furnaces Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces RGPQ- Series 80% A.F.U.E. Models with Input Rates from 45-105 kbtu (U.S. & Canadian Models)
More information80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS
80% Gas Furnace Single Stage - High Efficiency (Constant Torque) Motor 80G1-E Features and Benefits Form No. R80G1-E-100 (11/2011) CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped
More informationRuud Achiever Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationXC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace
TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA
More information93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS
93% Single Stage Gas Furnace Form No. JA931A-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped no
More informationGMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE
/ 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY
More information80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES
FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing
More informationFORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1
FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential
More informationFG7T (A and K Series)
TECHNICAL SPECIFICATIONS FG7T (A and K Series), Smartlite Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The
More informationDD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h
Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8
More informationW801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )
FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and
More informationRheem Classic Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationGAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE
FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization
More informationGMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h
// Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...
More informationW801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )
FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity
More informationGMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE
/ Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter
More informationTZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.
FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark
More informationGAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS
GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH) 1 SEASONAL EFFICIENCY 2 LARGEST REC A/C 3 FUEL
More informationRheem Classic Series Upflow/Horizontal Gas Furnace
THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE
More informationProduct Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat
PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different
More informationGKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h
Series up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Upflow Multi- Position, Multi-Speed Gas Furnace Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas
More informationGAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization
More informationVMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h
/ Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...
More informationEasily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency
Gas Furnaces PRODUCT SPECIFICATIONS INSTALLATION OPTIONS A vailable in Upflow/Horizontal and Counterflow models 80% AFUE 44,000 to 32,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER A luminized
More informationRheem Classic Series Downflow Gas Furnace
Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
More informationGAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization
More informationRheem Classic Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationRheem Classic Plus Series Downflow Gas Furnace
Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
More informationRheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace
Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More information80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal
More informationRheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace
THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace RGPT- Series 80% A.F.U.E. Input Rates 50-125 kbtu ENER UIDE Annual Fuel Utilization Efficiency
More informationGAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel
More informationRheem Value Series Downflow Gas Furnace
THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.
More information