Hot Gas 1 30 min +47 F Add 3 thickness for a pair of ends.

Size: px
Start display at page:

Download "Hot Gas 1 30 min +47 F Add 3 thickness for a pair of ends."

Transcription

1 CASE DATA AMPS Anti-Sweat 1.89 ECM Fan / # Fans 0.25/1 LED Lights 0.26 Drain Heater All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. Electric 1 45 min +65 F Hot Gas 1 30 min +47 F QFGCEI - - Reach In - Anthony 101LE Door Case BTUH - - LED Lights ECM Fan NOTE: For sizing conventional/individual condensing unit, add 8% to BTUH load. Facing Area 13 ft 2 Cubic Capacity 24.5 ft 3 Application Air Velocity Air -18 F 200 FPM -12 F -11 F 200 FPM -5 F Issue:

2 208 Circuit Case Data 2 Door 3 Door 4 Door 5 Door Power Supply 208/1/60 208/1/60 208/1/60 208/1/60 Compressor RLA Condenser Fan Motor Defrost Heaters Horse Power /4 3 Anti-Sweat STD Fan PSC Fan ECM Fan Light Amps (T8) LED Light Amps (Optimax Pro) Drain Pan Heater Condensate Pump Condensate orator Total Max. Amps drawn Minim. Circuit Ampacity Maxim. Overcurrent Protection Refrigerant - R404A Electric 1 45 min 65 F Add 3 thickness for a pair of ends NOTE: Options are not available after January 1, Condensing Unit QFGCEI - MCU - Reach-In - Anthony 101LE Door - Low BTUH per Door - T8 Lights PSC Fan 1455 ECM Fan 1425 BTUH per Door - LED Lights 2 Door Facing Area 24.9 ft 2 Cubic Capacity 47.0 ft 3 3 Door 4 Door 37.1ft ft ft ft 3 5 Door 61.9 ft ft NOTE: For sizing conventional/individual condensing units, add 8% to BTUH load. Air Velocity Air -18 F 250 FPM -12 F -11 F 250 FPM -5 F

3 Case Data Amps 208V Power Supply 208/1/60 Compressor RLA 9.2 Condenser Fan Motor 0.70 Heater 3.05 Minimum Circuit Ampacity 12.4 Maximum Overcurrent Protection 15 Horse Power V Power Supply 115/1/60 Anti-Sweat (10) 1.89 Anti-Sweat (Glass End) 0.97 PSC Fan 0.37 ECM Fan 0.30 Light Amps (T8) 0.98 Light Amps (LED) 0.26 Drain Pan Heater 0.22 Condensate Pump 0.56 Condensate orator 8.34 Minimum Circuit Ampacity 13.9 Maximum Overcurrent Protection 15 Refrigerant - R404A NOTE: Options are not available after January 1, (END) 37 3/ / /16 7 3/ /8 Add 3 thickness for a pair of ends Electric 1 45 min 65 F 5 9/16 CONDENSING UNIT 22 13/ / / " 81 1/ /32" 22 21/ / /32 3 1/ /4 Application: Specification Sheet QFGCEI - MCU - - Reach-In - Anthony 101LE Door BTUH per Door - LED Lights ECM Fan PSC Fan BTUH per Door - T8 Lights ECM Fan PSC Fan Application - Facing Area 13 ft 2 Cubic Capacity 24.5 ft 3 Air Velocity Air -11 F 200 FPM -5 F -18 F 200 FPM -12 F Issue:

4 CASE DATA AMPS 2 Door 3 Door 4 Door 5 Door Anti-Sweat ECM Fan / # Fans 0.50/2 0.75/3 1.00/4 1.25/5 LED Lights (Polaris) Drain Heater All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. Electric 1 45 min 65 F Hot Gas 1 30 min 47 F Assorted Shelving Options Available. QFGCEI - Reach In - Gemtron Polar RE Door - Low Case BTUH per Door LED Lights 2 Door 3 Door 4 Door 5 Door Facing Area (ft²) ECM Fan Cubic Capacity (ft³) NOTE: For sizing conventional/individual condensing unit, add 8% to BTUH load. The above case model, has case lengths that are UL and NSF approved. Ice Cream Frozen Food Air Velocity Air -18 F 300 FPM -11 F -11 F 300 FPM -4 F

5 CASE DATA AMPS 2 Door 3 Door 4 Door 5 Door Anti-Sweat STD Fan / # Fans 1.04/2 1.56/3 2.08/4 2.60/5 PSC Fan / # Fans 0.52/2 0.78/3 1.04/4 1.30/5 ECM Fan / # Fans 0.50/2 0.75/3 1.00/4 1.25/5 T8 Lights LED Lights (Optimax Pro) Drain Heater All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. Electric 1 45 min 65 F Hot Gas 1 30 min 47 F NOTE: Options are not available after January 1, Assorted Shelving Options Available. QFGCEI - Reach In - Eliminator Door (Anthony) Case BTUH per Door LED Lights STD Fan PSC Fan ECM Fan Add 100 BTUHs per door for T8 lights. NOTE: For sizing conventional/individual condensing unit, add 8% to BTUH load. Product Ice Cream Frozen Food 2 Door 3 Door 4 Door 5 Door Facing Area (ft 2 ) Cubic Capacity (ft 3 ) Air Velocity Air -17 F 300 FPM -11 F -10 F 300 FPM -4 F The above case model, has case lengths that are UL and NSF approved.

6 CASE DATA AMPS 2 Door 3 Door 4 Door 5 Door Anti-Sweat ECM Fan / # Fans 0.50/2 0.75/3 1.00/4 1.25/5 LED Lights (Optimax Pro) Drain Heater All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. Electric 1 45 min 65 F Hot Gas 1 30 min 47 F Assorted Shelving Options Available. QFGCEI - Reach In - Anthony 101LE Door - Low Case BTUH per Door LED Lights 2 Door 3 Door 4 Door 5 Door Facing Area (ft 2 ) ECM Fan NOTE: For sizing conventional/individual condensing unit, add 8% to BTUH load. Cubic Capacity (ft 3 ) Product Ice Cream Frozen Food Air Velocity Air -18 F 300 FPM -11 F -11 F 300 FPM -4 F The above case model, has case lengths that are UL and NSF approved.

7 CASE DATA AMPS Anti-Sweat 1.89 ECM Fan / # Fans 0.30/1 LED Lights (Polaris) 0.26 Drain Heater All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. Electric 1 45 min +65 F Hot Gas 1 30 min +47 F QFGCEI - - Reach In - Gemtron Polar RE Door Case BTUH - - LED Lights ECM Fan Facing Area 13 ft 2 Cubic Capacity 24.5 ft 3 NOTE: For sizing conventional/individual condensing unit, add 8% to BTUH load. Product Air Velocity Air -18 F 200 FPM -12 F -11 F 200 FPM -5 F Issue:

8 CASE DATA AMPS Anti-Sweat 1.45 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.25/1 T8 Lights 0.98 LED Lights (Optimax Pro) 0.17 Drain Heater All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. Electric 1 45 min +65 F Hot Gas 1 30 min +47 F NOTE: Options are not available after January 1, QFGCEI - - Reach In - Eliminator (Anthony) Case BTUH - LED Lights T8 Lights PSC Fan ECM Fan Frozen Food LED Lights T8 Lights PSC Fan ECM Fan NOTE: For sizing conventional/individual condensing unit, add 8% to BTUH load. Facing Area 13 ft 2 Cubic Capacity 24.5 ft 3 Product Air Velocity Air -17 F 200 FPM -12 F -10 F 200 FPM -5 F

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES GENERAL NOTES " - - -" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. 3rd

More information

O2.5UMAK-NRG O2.5UMAK-NRG. Multi-Deck Mobile Self-Contained Merchandiser 4', 6' & 8' Case (Meal Kit) SHIPPING WEIGHT GENERAL NOTES

O2.5UMAK-NRG O2.5UMAK-NRG. Multi-Deck Mobile Self-Contained Merchandiser 4', 6' & 8' Case (Meal Kit) SHIPPING WEIGHT GENERAL NOTES GENERAL "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. Nose lights

More information

OUM-NRG OUM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Meat / Produce / Seafood) GENERAL NOTES:

OUM-NRG OUM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Meat / Produce / Seafood) GENERAL NOTES: GENERAL "---" indicates that the feature is not an option with this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. Nose lights

More information

OHP-NRG OHP-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Produce) SHIPPING WEIGHT Case Weight OHP-NRG ---

OHP-NRG OHP-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Produce) SHIPPING WEIGHT Case Weight OHP-NRG --- GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or that the data is not yet available. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves.

More information

Center Mount Unit Coolers

Center Mount Unit Coolers LK-CMTB JAN 2018 Replaces LK-CMTB JULY 2017 Center Mount Unit Coolers Technical Guide s ACM Air Defrost ECM Electric Defrost Table of Contents Nomenclature 2 Features & Benefits 3 Performance Data 4 Specifications

More information

Shandong Vicot Air Conditioning Co.,Ltd. Air Cooled Condensing Unit

Shandong Vicot Air Conditioning Co.,Ltd. Air Cooled Condensing Unit Air Cooled Condensing Unit PERFORMANCE 10.00 SEER & 13.00 SEER Efficiency Range Cooling capacity from 1.5 to 5 tons T3 Tropical high efficiency Condensing units FEATURES Super quiet top air discharge Sheet

More information

O5DMH-NRG O5DMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT

O5DMH-NRG O5DMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves.

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-RLX-0817C Next-Gen All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost 4,100 to 45,900 BTUH Electric Defrost 2,700 to 33,000 BTUH Defrost

More information

LOW HEIGHT UNIT COOLER

LOW HEIGHT UNIT COOLER Publication No. RU-CTA-0818A Replaces RU-CTA-0712A Ceiling-Temp LOW HEIGHT UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost,00 to 27,00 BTUH Electric Defrost 5,00 to 27,00

More information

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS 1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM

More information

Thank you for choosing Hill PHOENIX for your product merchandising needs!

Thank you for choosing Hill PHOENIX for your product merchandising needs! Welcome to the 2011 Merchandisers Engineering Reference Manual. This manual provides detailed cross-sections, footprints and technical data for all of our current production models. The case data contained

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -

More information

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½

More information

High Profile Evaporator

High Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KHPE-PDI-3 Part # 1081588 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile orator Low & Medium Temperature Electric

More information

OHM-NRG OHM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

OHM-NRG OHM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES GENERAL " - - - " indicates that the feature is not an option with this case model and/or that the data is not available at this time. LED lights only. Maximum of 5 rows of Standard LED Output lighted

More information

Next-Gen All-Temp Low Profile Unit Cooler

Next-Gen All-Temp Low Profile Unit Cooler Publication No. WT-WLX-0918A Replaces WT-WLX-0618A Next-Gen All-Temp Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 4,100 to 45,900 BTUH Electric Defrost

More information

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. RU-RFH-1117A Replaces document RU-RFH-0917A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell

More information

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. RU-RFH-0117A Replaces document RU-RFH-0516A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 1½ thru 5 Ton Units Cooling: 17,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

KEP. Extended Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION

KEP. Extended Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin K30-KEP-PDI-2 Part # 1104191 PRODUCT SUPPORT web: k-rp.com/kep email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KEP Extended Profile Evaporator Air, Electric,

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RF Series Two-Stage, Single Phase Packaged Air Conditioner 16 SEER, 12 EER 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P7 Series single packaged air conditioners are

More information

Product Specifications Sheets

Product Specifications Sheets Product Specifications Sheets 35 Series Service Case Double Duty - Deli Pass-Thru Model Power Est. Ship Model No. Description Length Depth Height Voltage Amps HP/BTUs Cord Weight SC-CDS35-4 Self-contained

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

CAL / CEL / CDL / CGL / CKL

CAL / CEL / CDL / CGL / CKL CAL / CEL / CDL / CGL / CKL LOW PROFILE UNIT COOLERS > > CAPABILITIES: AIR DEFROST: 3,500-41,000 BTU/HR ELECTRIC DEFROST: 3,300-29,000 BTU/HR HOT GAS DEFROST: 3,300-29,000 BTU/HR www.coilexpert.com Partnership

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Product Specifications Sheets

Product Specifications Sheets Product Specifications Sheets 34N Series Double Duty Deli Power Est. Ship Model No. Description Length Depth Height Voltage Amps HP/BTUs Cord Weight SC-CDS34N-4 Self Contained 48" 36.25"** 55" 115 12.0

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

TMP. Medium Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION

TMP. Medium Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin T30--PDI-12 Part # 1082852 PRODUCT SUPPORT web: t-rp.com/tmp email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: Medium Profile Evaporator Air, Electric, Hot Gas

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

1/2 TO 6 HP INDOOR WATER COOLED CONDENSING UNITS

1/2 TO 6 HP INDOOR WATER COOLED CONDENSING UNITS NEXT-GEN WC-Series 1/2 TO 6 HP INDOOR WATER COOLED CONDENSING UNITS Publication No. WT-WWX-0618A 2 1/2 to 6 HP Next-Gen WC-Series Compact and Efficient Water Cooled Units Next-Gen WC-Series Water Cooled

More information

High Profile Evaporator

High Profile Evaporator High Profile orator PRODUCT DATA & INSTALLATION Bulletin K30-KHPHG-PDI-3 Part # 1081591 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Low & Medium Hot Gas Defrost

More information

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Split System Heat Pump Up to 16 SEER & 9.5 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

H Series Air Cooled Condensing Units 1/2 to 6 HP Brochure IK August, 2010

H Series Air Cooled Condensing Units 1/2 to 6 HP Brochure IK August, 2010 Air Cooled Condensing Units 1/2 to 6 HP Brochure IK502.16 August, 2010 1/2 to 3 HP 4 to 6 HP FEATURES AND OPTIONS Description Ice Kold s H-series condensing units are ideally suited for use in a variety

More information

MEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost.

MEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost. CH-MPTB June 2015 Replaces CH-MPTB Nov 2010 MEDIUM PROFILE UNIT COOLERS Technical Guide s HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2

More information

ELECTRIC HEAT AIR HANDLERS

ELECTRIC HEAT AIR HANDLERS ELECTRIC HEAT AIR HANDLERS 208/230V 1 1 /2 to 5 TONS High efficiency series for R-22 Certain models feature GE s new X-13 motor for enhanced SEER performance with most outdoor condensing units Multi-position

More information

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER High-Efficiency, R-410A 1½ to 5 Tons Cooling Capacity: 18,000 to 57,600 BTU/h Split System Heat Pump up to 14 SEER Heating Capacity: 18,000 to 59,000 BTU/h Standard Features R-410A chlorine-free refrigerant

More information

R-Series DUAL REFRIGERANT AIR COOLED CONDENSING UNITS 1/2 TO 6-1/2 HP

R-Series DUAL REFRIGERANT AIR COOLED CONDENSING UNITS 1/2 TO 6-1/2 HP Publication No. RU-REL-0414A Supersedes RU-REL -0413A R-Series DUAL REFRIGERANT AIR COOLED CONDENSING UNITS 1/2 TO 6-1/2 HP 1/2 to 3 HP 4 to 6 HP 2 DUAL REFRIGERANT AIR COOLED CONDENSING UNITS Description

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

MEDIUM PROFILE UNIT COOLERS Technical Guide

MEDIUM PROFILE UNIT COOLERS Technical Guide BN-MPTB August 2016 Replaces BN-MPTB, June 2015 MEDIUM PROFILE UNIT COOLERS Technical Guide s BMA Air Defrost BME/BML Electric Defrost BMG/BMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2

More information

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

Electronic Refrigerator Diagnostics

Electronic Refrigerator Diagnostics Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical

More information

Replacement Parts, W/D & Tech Data HHP Series

Replacement Parts, W/D & Tech Data HHP Series Replacement Parts, W/D & Tech Data HHP18-6 Series NOTE: This illustration is for reference only. The appearance of your unit may differ from the unit shown. KEY NO. DESCRIPTION PART NUMBER HHP18AKA1 HHP24AKA1

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

COMMERCIAL WALK-IN COOLERS AND FREEZERS

COMMERCIAL WALK-IN COOLERS AND FREEZERS COMMERCIAL WALK-IN COOLERS AND FREEZERS LSA Models Ideal for coolers above +34 F Low Silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 Btu/hr./10 F TD LSE, LSR and LST Models

More information

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF High-Efficiency Cooling Capacity: 18,000 to 57,600 BTU/h Heating Capacity: 18,000 to 59,000 BTU/h Split System Heat Pump Up to 15 SEER & 8.5 HSPF Contents Nomenclature... 2 Product Specifications... 3

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

Self-Contained PRICE LIST. April

Self-Contained PRICE LIST. April Self-Contained PRICE LIST April 2018 www.hussmann.com DDSS-4MC GSVM ISFGG ISMGG MD MD4060DA MDN NAV/NAVC SHM SM VRL VRM Pricing subject to change without notice. For additional resources, contact your

More information

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit

More information

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features

More information

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.

More information

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS GQ4SD Series Single Packaged Heat Pump 13 SEER The GQ4 Series single packaged units are high efficiency self contained cooling and heating units that can be installed on a roof

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TM TECHNICAL SPECIFICATIONS GQ4SD Series Single Packaged Heat Pump 13 SEER The GQ4 Series single packaged units are high efficiency self contained cooling and heating units that can be installed on a roof

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed

More information

FORM NO. HSC-543 AIR HANDLERS

FORM NO. HSC-543 AIR HANDLERS FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure

More information

DIMENSION AND SELECTION GUIDE

DIMENSION AND SELECTION GUIDE WW-SERIES WATER-TO-WATER UNITS DIMENSION AND SELECTION GUIDE RATED IN ACCORDANCE TO ISO STANDARD 13256-2:1998. MODEL DESIGNATION WW SERIES R 120 MODEL R= REVERSE CYCLE B 0 0 0 3 B EVAPORATOR SIZE CABINET

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 06.2016 Bosch Thermotechnology

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Medium Profile Unit Coolers

Medium Profile Unit Coolers CH-MPTB JAN 2018 Replaces CH-MPTB AUG 2016 Medium Profile Unit Coolers Technical Guide s HMA HME/HML HMG/HMF Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology

More information

2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil

2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil Specification 2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,

More information

Replacement Parts, W/D & Tech Data CAC Series

Replacement Parts, W/D & Tech Data CAC Series Replacement Parts, W/D & Tech Data CAC018-060 Series NOTE: This illustration is for reference only. The appearance of your unit may differ from the unit shown. KEY NO. DESCRIPTION PART NUMBER CAC018AKA1

More information

3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil

3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil Specification 3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

Specification. 3 Ton Convertible Air Handler TAM7A0C36H31SC TAM7A0C36 SPEC-1D

Specification. 3 Ton Convertible Air Handler TAM7A0C36H31SC TAM7A0C36 SPEC-1D Specification 3 Ton Convertible Air Handler TAG: SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h D ommercial 7½ - ½ Ton Packaged Air onditioners Up to. EER ooling apacity: 88,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8 Airflow Data... rankcase Heater...0

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils MHP4 Electric Heat Pump Packaged Thru-the-Wall Units FEATURES Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside condensing unit No external refrigerant

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units MCE4 Electric Heating / Electric Cooling Packaged Thru-the-Wall Units Form No.: MCE4-100 (07/2011) features Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside

More information

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units Electric Heating / Electric Cooling Packaged Units FORM NO. -100 (06/2017) FEATURES Up to 10.0 EER cooling efficiency Less than 2% cabinet air leakage Completely self-contained heating and cooling package

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS TM TECHNICAL SPECIFICATIONS Q4SD Series Single Packaged Heat Pump, Single Phase Q4SD-13 SEER 3-5 Ton Units Cooling: 30,000 to 58,000 Btuh Heating: 29,000 to 59,000 Btuh The Q4 Series single packaged heat

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally

More information