254 Series Convector. Standard Construction Features

Size: px
Start display at page:

Download "254 Series Convector. Standard Construction Features"

Transcription

1 American Bureau of Shipping Class I, Divisions and 2, Groups B, C and D Class II, Divisions and 2, Groups E, F and G Class I, Zones and 2, Groups IIB and H2 Applications Battery Storage Areas Chemical Plants Coal Handling Facilities Dry Cleaning Plants Gasoline Fueling/Storage Areas Grain Elevators Oil Refineries Paint Spraying/Storage Areas Petrochemical Plants Heatrex s explosion-proof convector is designed to provide a heavy duty and corrosion resistant heat source. Features include: Wide Selection of s: Four compact sizes to fit any space with ratings from 500 to 9,500 watts. Sloped Top Cabinet: Prevents objects from being set on top of the convector, which can restrict airflow and cause overheating. Single and Three-Phase: Unique design provides single and balanced three-phase loads in a single element. Gas and Dust Atmospheres: Three listings cover the entire field, two for hazardous gases and vapors and one for dust particles. Wet Locations: All unit sizes available with iridite- coated elements and powder-coated frames for NEMA wet locations. Standard Construction Features Element Grade A Nickel-Chromium heating coils are insulated with ceramics and magnesium oxide from the copper heater tube and fitted with large aluminum fins locked in place. Cabinet Heavy gauge galvanized steel cabinet is painted with a beige powder coat for durability. Cabinet should be mounted at least 6 inches (52 mm) above the floor. Factoryfurnished wall brackets make installation easy. Thermal Protection A linear limit, automatic reset thermal cutout is built into every unit. Complete Electrical Package For larger single-phase and all three-phase units, a built-on contactor and transformer option package are available. 9

2 Electrical Package Options All single-phase heaters rated over 22 amps or 277 volts and all three-phase heaters require a magnetic contactor. Some electrical combinations will also require a control transformer. To simplify field installation, these accessories are factory-mounted on the heater cabinet and factory pre-wired (not available on convectors). Code Option Description B2 Electric Control Option () (without thermostat) B2S Thermostat & () B Thermostat & (Group B) () S () S2 (Group B) () Classes I and II, Groups B, C, E, D, F and G includes contactor and transformer (as required). Required for all three-phase and single- phase heaters over 22 amps or 277 volts Classes I and II, Groups C, D, E, F and G includes thermostat, contactor and transformer (as required). Classes I and II, Groups B, C, D, E, F and G includes thermostat, contactor and transformer (as required). Thermostat has internal set point. Classes I and II, Groups C, D, E, F and G single-phase heaters rated up to 22 amps at volts. Use remote room thermostat for convectors. Classes I and II, Groups B, C, D, E, F and G single-phase heaters rated up to 22 amps at volts. Thermostat has internal set point. Use remote room thermostat 0275 for convectors. Code (2) () These options are not available on Convectors. Custom Option Code Option Description Type rated construction. Includes Iridite coated element assembly C Wet Locations and gasketed terminal box. Not available with options B2/S, S, or S2. Type rated construction with addition of stainless steel cabinet. Includes Iridite coated element assembly and gasketed terminal box. Not Corrosive-Resistant C2 Stainless Steel available with options B2/S, S, or S2. ONLY the cabinet is upgraded to Construction stainless steel. (2) = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. Code (2) C C Accessory Remote Thermostat Bimetal Switch Type Description Type Ratings Bulb and Capillary with Internal Set Point Adjustment Bulb and Capillary with Internal Set Point Adjustment Class, Div., Groups C & D Class II, Div., Groups E, F, & G Class, Div., Groups B, C & D Class II, Div., Groups E, F, & G Corrosion-Resistant Class, Div., Groups B, C, & D Class II, Div., Groups E, F & G SPDT SPDT SPST V, 22A 20-20V, 25A 277V, 22A 20-20V, 25A 277V, 22A Temp. Range o F ( o C) (0-2) 0-20 (5-9) 0-20 (5-9) Code 20

3 Class I, Divisions & 2, Groups B, C & D Ignition Temperature Code T2A, 56⁰F (280⁰C) Class I, Zones and 2 Groups IIB + H2 Use these heaters when ordering heaters without optional built-on controls () Phase Code () Optional Built-on 20.2 HX-25-F00052B N/A HX-25-F00052C N/A HX-25-F00052J N/A HX-25-F00052N N/A HX-25-F0002B N/A HX-25-F0002C N/A HX-25-F0002J N/A HX-25-F0002N N/A HX-25-F02082B N/R S HX-25-F02082C N/R S HX-25-F02082J N/R S HX-25-F02082N N/R S HX-25-F02082I B2 B HX-25-F02082U B2 B HX-25-F02082Z B2 B HX-25-F020252C N/R S HX-25-F020252D B2 B HX-25-F020252J N/R S HX-25-F020252N N/R S HX-25-F020252I B2 B 80.0 HX-25-F020252U B2 B HX-25-F020252Z B2 B HX-25-F0062C N/R S HX-25-F0062D B2 B HX-25-F0062J N/R S HX-25-F0062N N/R S HX-25-F0062I B2 B 80. HX-25-F0062U B2 B HX-25-F0062Z B2 B HX-25-F002D B2 B HX-25-F002J N/R S HX-25-F002N N/R S HX-25-F002I B2 B HX-25-F002U B2 B 600. HX-25-F002Z B2 B HX-25-F00652D B2 B HX-25-F00652J B2 B HX-25-F00652N B2 B HX-25-F00652I B2 B HX-25-F00652U B2 B HX-25-F00652Z B2 B HX-25-F00752D B2 B 20. HX-25-F00752JH B2 B HX-25-F00752N B2 B HX-25-F00752I B2 B HX-25-F00752U B2 B HX-25-F00752Z B2 B HX-25-F00952D B2 B HX-25-F00952J B2 B HX-25-F00952N B2 B HX-25-F00952I B2 B 80. HX-25-F00952U B2 B HX-25-F00952Z B2 B () Convectors are 60/50 Hz rated (2) = Assembly Stock, listed heaters ordered with custom (C) features are subject to longer lead times. () Thermostat only is load carrying or remote. 2

4 Class I, Divisions & 2, Groups C & D Class I, Zones and 2 Groups IIB Ignition Temperature Code T2A, 56⁰F (280⁰C) Optional Built-on () Phase Code () 20.2 HX-25-F0005B N/A HX-25-F0005C N/A HX-25-F0005J N/A HX-25-F0005N N/A HX-25-F000B N/A HX-25-F000C N/A HX-25-F000J N/A HX-25-F000N N/A HX-25-F0208B N/R S HX-25-F0208C N/R S HX-25-F0208J N/R S HX-25-F0208N N/R S HX-25-F0208I B2 B2S HX-25-F0208U B2 B2S HX-25-F0208Z B2 B2S HX-25-F02025C N/R S HX-25-F02025D B2 B2S HX-25-F02025J N/R S HX-25-F02025N N/R S HX-25-F02025I B2 B2S 80.0 HX-25-F02025U B2 B2S HX-25-F02025Z B2 B2S HX-25-F006C N/R S HX-25-F006D B2 B2S HX-25-F006J N/R S HX-25-F006N N/R S 7 0. HX-25-F006I B BS 80. HX-25-F006U B2 B2S HX-25-F006Z B2 B2S HX-25-F00D B2 B2S HX-25-F00J N/R S HX-25-F00N N/R S HX-25-F00I B2 BS HX-25-F00U B2 B2S 600. HX-25-F00Z B2 B2S HX-25-F0065D B2 B2S HX-25-F0065J B2 B2S HX-25-F0065N B2 B2S HX-25-F0065I B2 B2S HX-25-F0065U B2 B2S HX-25-F0065Z B2 B2S HX-25-F0075D B2 B2S 20. HX-25-F0075J B2 B2S HX-25-F0075N B2 B2S HX-25-F0075I B2 B2S HX-25-F0075U B2 B2S HX-25-F0075Z B2 B2S HX-25-F0095D B2 B2S HX-25-F0095J B2 B2S HX-25-F0095N B2 B2S HX-25-F0095I B2 B2S 80. HX-25-F0095U B2 B2S HX-25-F0095Z B2 B2S () Convectors are 60/50 Hz rated (2) = Assembly Stock, listed heaters ordered with custom (C) features are subject to longer lead times. () Thermostat only is load carrying or remote. 22

5 Class I, Divisions & 2, Groups B, C & D Ignition Temperature Code TA, 56⁰F (80⁰C) Class I, Zones and 2 Groups IIB + H2 Use these heaters when ordering heaters without optional built-on controls () Phase 20.2 HX-25-F060052B Code () Optional Built-on HX-25-F060052C N/A HX-25-F060052J N/A 0275 N/A HX-25-F060052N N/A HX-25-F06202B N/R S HX-25-F06202C N/R S HX-25-F06202J N/R S HX-25-F06202N N/R S2 7.0 HX-25-F06202I B2 B HX-25-F06022B N/R S HX-25-F06022C N/R S HX-25-F06022D B2 B HX-25-F06022J N/R S HX-25-F06022N N/R S HX-25-F06022I B2 B HX-25-F06022U B2 B HX-25-F06022Z B2 B HX-25-F06022C N/R S HX-25-F06022D B2 B 20. HX-25-F06022J N/R S HX-25-F06022N N/R S HX-25-F06022I B2 B 80.8 HX-25-F06022U B2 B 600. HX-25-F06022Z B2 B HX-25-F060502D B2 B HX-25-F060502J N/R S HX-25-F060502N N/R S2 7. HX-25-F060502I B2 B HX-25-F060502U B2 B HX-25-F060502Z B2 B () Convectors are 60/50 Hz rated (2) = Assembly Stock, listed heaters ordered with custom (C) features are subject to longer lead times. () Thermostat only is load carrying or remote. 2

6 Class I, Divisions & 2, Groups C & D Class I, Zones and 2 Groups IIB Ignition Temperature Code TA, 56⁰F (80⁰C) () Phase 20.2 HX-25-F06005B Code () Optional Built-on HX-25-F06005C N/A HX-25-F06005J N/A N/A HX-25-F06005N N/A HX-25-F0620B N/R S HX-25-F0620C N/R S HX-25-F0620J N/R S HX-25-F0620N N/R S 7.0 HX-25-F0620I B2 B2S HX-25-F0602B N/R S 208. HX-25-F0602C N/R S HX-25-F0602D B2 B2S HX-25-F0602J N/R S HX-25-F0602N N/R S HX-25-F0602I B2 B2S HX-25-F0602U B2 B2S HX-25-F0602Z B2 B2S HX-25-F0602C N/R S HX-25-F0602D B2 B2S 20. HX-25-F0602J N/R S HX-25-F0602N N/R S HX-25-F0602I B2 B2S 80.8 HX-25-F0602U B2 B2S 600. HX-25-F0602Z B2 B2S HX-25-F06050D B2 B2S HX-25-F06050J N/R S HX-25-F06050N N/R S 7. HX-25-F06050I B2 B2S HX-25-F06050U B2 B2S HX-25-F06050Z B2 B2S () Convectors are 60/50 Hz rated (2) = Assembly Stock, listed heaters ordered with custom (C) features are subject to longer lead times. () Thermostat only is load carrying or remote. 2

7 Class II, Divisions & 2, Groups E, F & G Ignition Temperature Code TC, 20⁰F (60⁰C) () Phase 20.2 () Convectors are 60/50 Hz rated (2) = Assembly Stock, listed heaters ordered with custom (C) features are subject to longer lead times. () Thermostat only is load carrying or remote. Accessory Remote Thermostat HX-25-F08005B Code () Optional Built-on HX-25-F08005C N/A HX-25-F08005J N/A N/A HX-25-F08005N N/A HX-25-F08200B N/R S HX-25-F08200C N/R S HX-25-F08200J N/R S HX-25-F08200N N/R S HX-25-F08200I B2 B2S 20.2 HX-25-F0807B N/R S HX-25-F0807C N/R S HX-25-F0807D B2 B2S HX-25-F0807J N/R S HX-25-F0807N N/R S 7.9 HX-25-F0807I B2 B2S 80 2 HX-25-F0807U B2 B2S HX-25-F0807Z B2 B2S HX-25-F0802C N/R S HX-25-F0802D B2 B2S 20. HX-25-F0802J N/R S HX-25-F0802N N/R S HX-25-F0802I B2 B2S 80.8 HX-25-F0802U B2 B2S 600. HX-25-F0802Z B2 B2S Switch Type Description Type Ratings Temp. Range o F ( o C) Code Bimetal Class, Div., Groups C & D Class II, Div., Groups E, F, & G SPDT V, 22A (0-2) 0275 Bulb and Capillary with Internal Set Point Adjustment Class, Div., Groups B, C & D Class II, Div., Groups E, F, & G SPDT 20-20V, 25A 277V, 22A 0-20 (5-9) Bulb and Capillary with Internal Set Point Adjustment Corrosion-Resistant Class, Div., Groups B, C, & D Class II, Div., Groups E, F & G SPST 20-20V, 25A 277V, 22A 0-20 (5-9) 25

8 Option S Thermostat (External Set Point) Option S2 Thermostat (External Set Point) Thermostat is rated for Class I, Groups C and D Class II Groups E, F and G Thermostat is rated for Class I, Groups B, C and D Class II Groups E, F and G Option B2S Optional Built-on Thermostat (External Set Point) Control Package Option B Control Package w/ Thermostat (Internal Set Point) Thermostat is rated for Class I, Groups C and D Class II Groups E, F and G Thermostat is rated for Class I, Groups B, C and D Class II Groups E, F and G Dimensions and Weights Dimensions - In. (cm) Weight - Lb (kg) Without Length (L) Height (H) Depth (D) 26 (66) 6 (5) -/2 () (5.9) 2 26 (66) 6 () 8 (20) 27 (2.2) 9 (99) 6 () 8 (20) 6 (6.) 67-/2 (7) 6 () 8 (20) 60 (27.2) 26

Convector. Standard Construction Features

Convector. Standard Construction Features American Bureau of Shipping Class I, Divisions and 2, Groups B, C and D Class II, Divisions and 2, Groups E, F and G Class I, Zones and 2, Groups IIB and H2 Applications Battery Storage Areas Chemical

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary

More information

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities 3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits

More information

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug Explosion Proof Drop Light - 12 Volt AC/DC - 100 Watt Incandescent - 25' Cord - Twist Lock Plug Part #: EPL-DL-12-25 Made in the USA The Larson Electronics EPL-DL-12-25 Explosion Proof Hand Lamp is U.L.

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

Jefferson Electric Class I Division 2 Transformers for hazardous locations

Jefferson Electric Class I Division 2 Transformers for hazardous locations Class I Division 2 Jefferson Electric Class I Division 2 Transformers for hazardous locations Jefferson Electric offers a full line of Class I Division 2 transformers. Jefferson Electrics Class I Division

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA) 804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit. Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,

More information

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction SPECIFICATIONS 6 to 480 kw and higher CIRCULATION HEATERS CH & CHP SERIES Flanged construction 208 volt through 575 volt, 3 phase 5 to 40 watts/in 2 and higher NEMA 4/12 Terminal housing DESCRIPTION Type

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS Reed Switches and Proximity Sensors 1 REED SWITCHES HIGH POWER 7 UNIVERSAL HIGH POWER & HIGH VOLTAGE 7 Form A Form C Form C Form A Form C 196W 134W 156W 634W 637W 907W 834W 933W

More information

3900 Series Hydronic Electric Baseboard Heater

3900 Series Hydronic Electric Baseboard Heater 3900 Series Hydronic Electric Baseboard Heater Permanent mount self contained unit. Heating elements are immersed in a heat transferring liquid enclosed by a Copper tube casing with Aluminum fins. Powder

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems AC Leak Freeze AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems Will continue to seal additional Leaks for up to 1 year that meet testing specifications Does not contain

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h DX11S Commercial Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube / aluminum fin coil Brass liquid and suction service valves High- and low-pressure

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:

More information

Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap

Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap Part #: EPF-10P.3-NFK-50C Page: 1 Made in Texas The EPF-10P.3-NFK-50C from Larson Electronics is an Explosion

More information

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps. Applications Enclosed and gasketed, non-metallic emergency lighting system suitable for use in areas where flammable gases or vapors may become present due to abnormal, unusual or accidental conditions

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Explosion Proof LED String Lights - 7 lights - Class 1 Division 1 and Class 2 Division 1

Explosion Proof LED String Lights - 7 lights - Class 1 Division 1 and Class 2 Division 1 Explosion Proof LED String Lights - 7 lights - Class 1 Division 1 and Class 2 Division 1 Part #: EPL-SL-7-LED Page: 1 Made in the USA The Larson Electronics EPL-SL-10-LED Explosion Proof String Light set

More information

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2 Hoffman s new ZonEX ATEX-certified enclosures can be used in Zone 1- and Zone 2-rated applications throughout the world. Our NEMA Type 9 enclosures are designed for use in Class II Division 1 and 2 locations

More information

Hazardous Factory Sealed Control Devices

Hazardous Factory Sealed Control Devices Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm

Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm Part #: EPL-DL-70LED-24 Page: 1 Made in the USA The EPL-DL-70LED-24 Explosion Proof Dock Light is U.L. approved

More information

POSITION TRANSMITTERS

POSITION TRANSMITTERS POSITION TRANSMITTERS GENERAL DESCRIPTION Jordan Control s Series of position transmitters are rugged, compact industrial components that couple a precision feedback component and/or limit switches to

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor Mercmaster III HID 50-250 Watt Luminaires Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing and other areas where

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.     DESCRIPTION TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

Heating Cable. Construction

Heating Cable. Construction MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

SRH2. Steam Rig Heater. Industrial Grade Heat-Exchanger Unit Heaters. CRN: 0H C 150 psig (1034 KPa)

SRH2.   Steam Rig Heater. Industrial Grade Heat-Exchanger Unit Heaters. CRN: 0H C 150 psig (1034 KPa) SRH2 EAC Ex models available. Contact factory! Steam Rig Heater CRN: 0H14931.2C 150 psig (1034 KPa) Industrial Grade Heat-Exchanger Unit Heaters www.hazlocheaters.com is a manufacturer of industrial-grade

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

Plugs and Receptacles: Hazardous Location

Plugs and Receptacles: Hazardous Location U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.   DESCRIPTION FEATURE TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

Compact electric actuators for 90 operation of 1/4 turn valves providing a range of torque outputs up to 1645 Nm.

Compact electric actuators for 90 operation of 1/4 turn valves providing a range of torque outputs up to 1645 Nm. Compact electric actuators for 90 operation of 1/4 turn valves providing a range of torque outputs up to 1645 Nm. Features Gearcasing and enclosure is ESPC coated anodised aluminium, except Model 003 which

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

SKINNER Intrinsically Safe Series Four-Way

SKINNER Intrinsically Safe Series Four-Way SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air

More information

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940 AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940 NEMA 4X C1D2/C2D1 INDUSTRIAL HIGH LUMEN LED EMERGENCY LIGHT DUAL-LITE.COM INNOVATIVE LED NEMA 4X C1D2/C2D1 Industrial Emergency Light The Dynamo Series offers

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

EHB Series Explosion Proof Heavy Duty Belt Drive Exhaust Fans Data sheet

EHB Series Explosion Proof Heavy Duty Belt Drive Exhaust Fans Data sheet General Characteristics of EHB Series Exhaust Fan Used in industrial and commercial environments. May be used indoors only unless they have protection from the elements. The EHB Series are industrial fans

More information

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors

More information

Lighting: Explosionproof Area HID. Applications. Standard Materials

Lighting: Explosionproof Area HID. Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting. Spring Applied Power-Off Operation Power-Off Operation Inertia Dynamics AC-style, spring applied motor brakes are designed to decelerate or park inertial loads when the voltage is turned off, either intentionally

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER UNHA-T2CA-T3CA-T4CA Universal Air Handler Multi-Zone Only Rev. 1.0 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT

More information

Hazardous Duty Applications

Hazardous Duty Applications Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks

More information

Refrigerators/Freezers

Refrigerators/Freezers Explosion-Proof, Corrosion-Resistant Refrigerator Flammable Material Storage Refrigerator/Freezer Laboratory Freezer Lab-Line offers a complete line of refrigerators and freezers to accommodate virtually

More information

BHH Product Specifications

BHH Product Specifications BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards

More information

Heating Cable. Description

Heating Cable. Description Single Entry Power Connection Kit NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Lighted or Non-Lighted Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power, Splice or Tee Connection

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES TECHNICAL GUIDE MODELS: N*AH Modular Air Handlers For use w / Split System Cooling & Heat Pump 600-2000 CFM Blowers 2-5 Ton Coils Optional 1 & 3 Electric Heaters DESCRIPTION This unique modular system

More information

( )

( ) (1-800-492-8826) OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels

More information

(770)

(770) (770) 345-0010 OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments

More information

FACTORY SEALED CONTROLS - INTRODUCTION

FACTORY SEALED CONTROLS - INTRODUCTION FACTORY SEALED - INTRODUCTION Contact Factory for other certification details D2CU Factory Sealed Contact Block Applications Seal-XM Factory Sealed push button stations, selector switches, pilot lights

More information

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB

More information

Consider The Possibilities...

Consider The Possibilities... FS/FD Air-Cooled Fluid Cooler Catalog 710.1 Consider The Possibilities... Cools most any non-corrosive fluid Closed-circuit cooling avoids contamination Cold weather economizer for interior cooling loads

More information

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel Part #: HAL-48-2L-LED-BMSW-G2 Page: 1 Made in the USA The Larson Electronics HAL-48-2L-LED-BMSW-G2 Hazardous

More information

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug 25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug Part #: EXHL-SFC-LE1-50C-1227-EPP Page: 1 Made in Texas The EXHL-SFC-LE1-50C-1227-EPP from Larson Electronics is an

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton. AFAIR12B Air Conditioners Features Top discharge directs hot air and noise away from the living area Durable Copeland scroll compressor with internal pressure relief valves and inherent thermal protection

More information

KH Series Kemlux III Enclosed/Gasketed

KH Series Kemlux III Enclosed/Gasketed For use in corrosive, harsh, hazardous applications such as chemical, petrochem, marine, power generation, pharmaceutical, or food processing plants Mogul base socket on tanks C, D & E Medium base socket

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

Explosion Proof LED Drop Light / Trouble Light - Low Voltage 7 Watt LED Foot Cord - 12V24V AC

Explosion Proof LED Drop Light / Trouble Light - Low Voltage 7 Watt LED Foot Cord - 12V24V AC Explosion Proof LED Drop Light / Trouble Light - Low Voltage 7 Watt LED - 100 Foot Cord - 12V24V AC Part #: EHL-LED-7W-100LV Page: 1 Made in the USA The EHL-LED-7W-100LV from Larson Electronics is an Explosion

More information

Explosion Proof LED Drop Light / Trouble Light -10 Watt LED - 50 Foot SOOW Cord

Explosion Proof LED Drop Light / Trouble Light -10 Watt LED - 50 Foot SOOW Cord Explosion Proof LED Drop Light / Trouble Light -10 Watt LED - 50 Foot SOOW Cord Part #: EHL-LED-7W-50 Made in the USA The Larson Electronics EHL-LED-7W-50 Explosion Proof LED Drop Light / Trouble Light

More information

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration

More information

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class

More information

TXB Series Explosion Proof

TXB Series Explosion Proof General Characteristics of TXB Series The TXB Series is recommended for most paint spray applications because the motor is out of the air stream and not exposed to paint overspray. For Industrial and commercial

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) 4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are

More information

Explosion Proof 70W LED Light Fixture - C1D2 - Adjustable Magnet Base - Curved Mounting Surfaces

Explosion Proof 70W LED Light Fixture - C1D2 - Adjustable Magnet Base - Curved Mounting Surfaces Explosion Proof 70W LED Light Fixture - C1D2 - Adjustable Magnet Base - Curved Mounting Surfaces Part #: EPLC2-AMB-70LED-50 Page: 1 The Larson Electronics EPLC2-AMB-70LED-50 Low Profile Adjustable Magnetic

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Magnetic Mount 60 Watt Low Profile LED Flood Light - Glare Shield - 10' Cord V AC

Magnetic Mount 60 Watt Low Profile LED Flood Light - Glare Shield - 10' Cord V AC Magnetic Mount 60 Watt Low Profile LED Flood Light - Glare Shield - 10' Cord - 120-277V AC Part #: LEDWP-600E-M-10C Page: 1 The LEDWP-600E-M-10C Magnetic Mount LED Flood Light offers high light output

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount 150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower - 5-12' -Surface Mount Part #: EPL-APM-150LED-RT Page: 1 Made in the USA The EPL-APM-150LED-RT Telescoping Pole Mounted Explosion

More information

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens 1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide

More information

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin

More information

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT) 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Low Profile Hazardous Area Fluorescent Light - 4 Foot 2 Lamp - Lay-In Mount -Front Load Troffer

Low Profile Hazardous Area Fluorescent Light - 4 Foot 2 Lamp - Lay-In Mount -Front Load Troffer Low Profile Hazardous Area Fluorescent Light - 4 Foot 2 Lamp - Lay-In Mount -Front Load Troffer Part #: HAL-LI-48-2L-T8 Made in the USA The Larson Electronics HAL-LI-48-2L-T8 Hazardous Area Fluorescent

More information

150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord

150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord 150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord Part #: EPLC2-LED-150W-RT-JB2-25C The Larson Electronics EPLC2-LED-150W-RT-JB2-25C Explosion Proof LED Flood Light

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

Tubular Heaters Flanged

Tubular Heaters Flanged UL and C-UL Recognized-E177353 Features Ratings and sizes other than those listed are available. 150# rating ANSI carbon steel flange. Steel, stainless steel, copper, or incoloy sheathed elements. Optional

More information

Explosion Proof Quadpod Mount - Single 150 Watt Led Light foot cord

Explosion Proof Quadpod Mount - Single 150 Watt Led Light foot cord Explosion Proof Quadpod Mount - Single 150 Watt Led Light - 100 foot cord Part #: EPL-TP-1x150LED-100 Page: 1 Made in the USA The EPL-TP-1x150LED-100 Quadpod Mounted Explosion Proof LED Light Tower from

More information

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING (598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil

More information

Industrial Electric Convectors

Industrial Electric Convectors Industrial Electric Convectors for /IECEx hazardous areas SPACE EATING New optimized range! The /IECEx industrial convectors by CETAL are designed in a particularly robust way for space heating in hazardous

More information