DA/CL 74C Gear Motor and PCB

Size: px
Start display at page:

Download "DA/CL 74C Gear Motor and PCB"

Transcription

1 /L 74 Gear Motor and P Technical User Guide English: For other language variants of this document we refer to: Español: Para otras variantes del idioma de este documento, visite: Français: Pour les versions dans d'autres langues de ce document veuillez consulter:

2 2 Technical User Guide Program Version The product described in this manual holds software. This manual corresponds to: Software version 3.3 It was released in Product and ocumentation hanges SKOV /S reserve the right to change this document and the product herein described without further notice. In case of doubt, please contact SKOV /S. ate of change appears from the front and back of this manual. ote ll rights reserved SKOV /S. o part of this manual may be reproduced in any manner whatsoever without the express written permission from SKOV /S. SKOV /S has made all reasonable efforts to ensure the accuracy of the information contained in this manual. Should any mistakes or imprecise information occur in spite of this, SKOV /S would appreciate being notified thereof. Irrespective of the above, shall not accept any liability with regard to loss or damage caused or alleged to be caused by reliance on any information contained herein. opyright 2013 by SKOV /S. /L 74 Gear Motor and P

3 Technical User Guide 3 1 Product escription Mounting Guide Electrical onnection Replacing gear motor Setting the Jumper hanging from a 74 P to a 74 P onnecting Wires in the 74 abinet Using Splicing Sleeves / 74 O/OFF / 74 O/OFF with External apacitor / 74 O/OFF 400 V / 74 Stepless / 74 Stepless with External apacitor V O/OFF to 600 LP-2 without Winch Motor Stepless to 600 LP-2 without Winch Motor Replacing the 74 P onnecting Wires in the 74 abinet Using I Rail Terminals O/OFF O/OFF with External apacitor O/OFF 400 V Stepless Stepless with External apacitor V O/OFF to 600 LP-2 without Winch Motor Stepless to 600 LP-2 without Winch Motor onnecting Wires in 24 V ontrol Valve for Room Heating LE Indication Troubleshooting / Remedy /L 74 Gear Motor and P

4 4 Technical User Guide 1 Product escription 74 Gear Motor and P for variants of 74 winch motors Figure 1: 74 part list Position rticle no. Quantity 74 part list P PT screw 3x6, zinc-plated, pozi magnet retainer with magnet Relay cable 0.75 mm 2x300 1x motor Terminal block for chassis 12P 4 mm2 Used for L 74 with 8 m gear Wire 220 mm 1.0 mm2 black Splicing sleeve single 2.5 mm Wire 325 x 0,75 mm2 red 2crimp TUG 74 Printed ircuit oard E gear motor complete Table 1: Part list /L 74 Gear Motor and P

5 Technical User Guide 5 2 Mounting Guide escription of how to replace gear motor, see section escription of how to connect wires and set the jumper when changing from a 74 P to a 74 P, see sections and When changing from a 74 P to a 74 P, see sections and Electrical onnection Qualified personnel in accordance with the applicable national and international standard E and any other EU standards that are applicable in Europe must perform installation, service and fault finding of al electrical equipment. The installation of a supply isolator is required for each motor and power supply, so maintenance of electrical equipment can be carried out in a dead environment. Supply isolator is not supplied by SKOV /S Replacing gear motor () 1) isconnect power to 74. 2) Remove wires from the terminal block (). 3) ctivate the manual release (), and turn the swivel shutter clockwise until it is in closed position (). 4) Remove screws or press the snap lock () to the side. 5) Remove retaining disc (E) and locking screw (F). 6) Pull the gear motor (G) off the swivel shutter shaft. () (G)(E) (F) () () 7) Press new gear motor (G) onto the swivel shutter shaft, screw () the gear motor (G) into 74. 8) Mount retaining disc (E) ) and locking screw (F). 9) ctivate the manual release (), and turn the swivel shutter () counterclockwise until it opens towards the mechanical end stop and clockwise until it is in closed position (). 10) Mount the wire from the terminal block () and the house computer as described in section on P. 11) onnect power to 74. () 12) LIRTE pursuant to section and /L 74 Gear Motor and P

6 6 Technical User Guide Setting the Jumper When changing Ps, it is important to determine how to set the jumper on the P to give the 74 the desired function. REVERSE 90º 0º Figure 2: Jumper setting O.. = Open ollector (transistor output) 0º 90º O/OFF ontrol voltage 24 V => lose. ontrol voltage 0 V => Open. Feedback signal > 0.5 V => O.. turns O. Feedback signal > 1.8 V (15 degree opening) => relay turns O. STEPLESS ontrol voltage 24 V/0 V => Open. 0 V/24 V => lose. Feedback signal > 0.5 V => O.. turns O. Feedback signal > 9.2 V (85 degree opening) => relay turns O V LOG The control voltage increases together with the opening degree. 2.3 V = 23% open. The feedback signal increases together with the opening degree. Feedback signal > 0.5 V => O.. turns O. Feedback signal > 0.5 V => relay turns O. O/OFF REVERSE ontrol voltage 24 V => lose. The feedback signal increases together with the opening degree 0.25 V= closed=90. Feedback signal > 0.5 V => O.. turns O. Feedback signal > 1.8 V (15 degree opening) => relay turns O. LOG REVERSE The control voltage increases reverse the opening degree. 2.3 V = 77% open. The feedback signal increases reverse the opening degree. Feedback signal > 0.5 V => O.. turns O. Feedback signal > 0.5 V => relay turns O. STEPLESS 15 ontrol voltage 24 V/0 V => Open. 0 V/24 V => lose. Feedback signal > 0.5 V => O.. turns O. Feedback signal > 1.8 V (15 degree opening) => relay turns O. STEPLESS REVERSE ontrol voltage 24 V/0 V => Open. 0 V/24 V => lose. Feedback signal > 0.5 V => O.. turns O. Feedback signal > 9.2 V (85 degree opening) => relay turns O. /L 74 Gear Motor and P

7 Technical User Guide hanging from a 74 P to a 74 P Remember to set the jumper on the 74 P. For jumper setting, see section Setting the Jumper. For wiring, see section onnecting Wires in the 74 abinet Using Splicing Sleeves 1) isconnect power to 74. 2)Remove the cover screws (). () () (E) () () 74 with an O/OFF P 3)Remove the motor plug (). () 74 with a stepless P () (E) () 4)Remove the screws retaining the P (). 5) Wires retain the old P until the new P has been mounted. 6)Remove the rotary latch (). 7)Remove the motor (E). () (E) () 74 with an anolog P /L 74 Gear Motor and P

8 8 Technical User Guide (F) 8) Mount the magnet (F). Push the magnet down to the bottom of the hole. Mounting the magnet (I) () Mounting the 74 P (H) () (G) 9) Mount the 74 P with the screws (). 10) Move one wire at a time from the defective P to the new P's terminal block (G) according to wiring procedure, see section ) Set the jumper to the desired type of 74 (H), see section ) Mount the new motor (E). (J) L 74 with 8 m gear (H) () 13) Remount the motor plug (); remember to cross the wires when mounting in L 74 with 8 m gear, see picture. 14) onnect power to ) Press the LIRTE button (I). alibrate 74 before calibration of the climate computer. The winch motor / shutter must open completely and then close completely. Meanwhile, the light must be constantly on (J). (G) 16) Remount the cover (). 17) heck whether the fault has disappeared. (I) /L 74 Gear Motor and P

9 O/OFF LIRTE Technical User Guide onnecting Wires in the 74 abinet Using Splicing Sleeves / 74 O/OFF onnecting wires for the winch motor and fan. When changing from a 74 P to a 74 P. 74 P Power and signal for the fan O/OFF F E 15º Move the regulated phase from terminal 16 to 14. Move PE protective earthing from terminal 14 to available terminals without terminal numbers. Signal and control voltage from 74 P to 74 P Move the 24 V wire from terminal 1 to H1. Move the O/OFF wire from terminal 2 to H2. 74 P E Move the 0 V wire from terminal 3 to H3. O/OFF G H H1 H2 H3 H6 H7 H8 H9 H 10a 11a H12a E Internal wires from 74 to 74 P F Remove the 4-core cable. G onnect the brown wire () from terminal 12 to H12a. H onnect the black wire (K) between terminal 10,11 and terminal H10a/H11a. Figure 3: O/OFF with splicing sleeves K /L 74 Gear Motor and P

10 O/OFF LIRTE Technical User Guide / 74 O/OFF with External apacitor onnecting wires for the winch motor and fan. When changing from a 74 P to a 74 P. 74 P Power and signal for fan O/OFF L F E 15º Move the regulated phase from terminal 16 to 14. Move PE protective earthing from terminal 14 to available terminals without terminal numbers. Signal and control voltage from 74 P to 74 P Move the 24 V wire from terminal 1 to H1. Move the O/OFF wire from terminal 2 to H2. 74 P E Move the 0 V wire from terminal 3 to H3. O/OFF L G H H1 H2 H3 H6 H7 H8 H9 H11a H12a E O/OFF Internal wires from 74 to 74 P F Remove the 4-core cable. G onnect the brown wire () from terminal 12 to H12a. H onnect the black wire (K) between terminal 10,11 and terminal H10a/H11a. Figure 4: O/OFF external capacitor with splicing sleeves K /L 74 Gear Motor and P

11 LIRTE 16 Technical User Guide / 74 O/OFF 400 V onnecting wires for the winch motor and fan. When changing from a 74 P to a 74 P. 74 P Power and signal for fan 400 V L2 L3 400 V L2 L L3 L2 ontactor 16 E O/OFF 15º Move PE protective earthing from terminal 14 to available terminals without terminal numbers. Signal and control voltage from 74 P to 74 P Move the 24 V wire from terminal 1 to H1. Move the O/OFF wire from terminal 2 to H W V U Move the 0 V wire from terminal 3 to H3. Internal wires from 74 to 74 P 400 V L2 L3 400 V L2 L3 F G 74 P H1 H2 H3 H6 H7 H8 H9 H 10a 11a H12a O/OFF E Remove the 4-core cable. F onnect the brown wire () from terminal 12 to H12a. G onnect the black wire (K) between terminal 10,11 and terminal H10a/H11a L3 L2 ontactor K 1 13 W V U Figure 5: O/OFF 400 V with splicing sleeves /L 74 Gear Motor and P

12 /- / _ 12 Technical User Guide / 74 Stepless LIRTE onnecting wires for the winch motor and fan. When changing from a 74 P to a 74 P. * * * * G H 74 P º 74 P H1 H2 H3 H6 H7 H8 H9 E F H 10a 11a H12a F E /- /- 0-1 Power and signal for fan Move PE protective earthing from terminal 14 to available terminals without terminal numbers. Signal and control voltage from 74 P to 74 P Move the /-24 V wire from terminal 1 to H1. Move the /-24 V wire from terminal 3 to H2. Move the 0 V wire from terminal 8 to H8. E Move the feedback wire from terminal 7 to H7. F Move the wire from terminal 6 to H6. Internal wires from 74 to 74 P G Remove the 4-core cable. H onnect the wire between terminal 10 and 11. Figure 6: Stepless with splicing sleeves * Internal Speed ontrol When using emergency opening (78T,278T and 378T), move the following wires in the house computer and emergency opening. Move wire F from 10 V to 24 V power supply in emergency opening. (F6 or 7) Move wire from 0 V to 0 V power supply from emergency opening. (Q1) When using emergency opening O/OFF (78M, 278M and 378M), move the following wires in the house computer. Move wire F from 10 V to 24 V power supply from emergency opening. (Q2, Q3, Q4 or Q5) Move wire from 0 V to 0 V power supply from emergency opening (Q1) and connect it to 4/17/17 on the main module. /L 74 Gear Motor and P

13 /- / Technical User Guide 13 LIRTE / 74 Stepless with External apacitor onnecting wires for the winch motor and fan. When changing from a 74 P to a 74 P. * * * * L L G H 74 P º 74 P H1 H2 H3 H6 H7 H8 H9 H 10a 11a H12a E 0-1 F 1 F E /- /- 0-1 Power and signal for fan Move PE protective earthing from terminal 14 to available terminals without terminal numbers. Signal and control voltage from 74 P to 74 P Move the /-24 V wire from terminal 1 to H1. Move the /-24 V wire from terminal 3 to H2. Move the 0 V wire from terminal 8 to H8. E Move the feedback wire from terminal 7 to H7. F Move the wire from terminal 6 to H6. Internal wires from 74 to 74 P G Remove the 4-core cable. H onnect the wire between terminal 10 and 11. Figure 7: Stepless external capacitor with splicing sleeves * Internal Speed ontrol When using emergency opening (78T, 278T and 378T), move the following wires in the house computer and emergency opening. Move wire F from 10 V to 24 V power supply in emergency opening. (F6 or 7) Move wire from 0 V to 0 V power supply from emergency opening. (Q1) When using emergency opening O/OFF (78M, 278M and 378M), move the following wires in the house computer. Move wire F from 10 V to 24 V power supply from emergency opening. (Q2, Q3, Q4 or Q5) Move wire from 0 V to 0 V power supply from emergency opening (Q1) and connect it to 4/17/17 on the main module. /L 74 Gear Motor and P

14 LIRTE Technical User Guide V onnecting wires for the winch motor. When changing from a 74 P to a 74 P. For connecting wires for the fan, see mounting of O/OFF and stepless P Signal, control voltage and internal wires from 74 P to 74 P Move the 0-10 V feedback from terminal 6 to H7. Move the 0-10 V signal from the computer from terminal 5 to H2. Move 24 V from terminal 2 to H6. Move 0 V from terminal 1 to H3. 74 P H1 H2 H3 H6 H7 H8 H9 H H Figure 8: 0-10 V winch motor with splicing sleeves /L 74 Gear Motor and P

15 16 Technical User Guide O/OFF to 600 LP-2 without Winch Motor onnecting wires for the 600 LP motor control. When changing from a 74 P to a 74 P. For connecting wires for the winch motors, see mounting of O/OFF, stepless and 0-10 V P RJ12 U E 15º Relay P K onversion P Power and signal to fan Move PE protective earthing from terminal 14 to available terminals without terminal numbers. Signal and control voltage from 74 P to 74 P Remove the relay P and the wires to it. onnect the wire from terminal 5 to terminal H8. onnect the wire from terminal 4 to terminal H9. 74 P Internal wires from 74 to 74 P E Remove the 4-core cable. Figure 9: 74 O/OFF to 600 LP with splicing sleeves /L 74 Gear Motor and P

16 16 16 Technical User Guide Stepless to 600 LP-2 without Winch Motor onnecting wires for the 600 LP motor control. When changing from a 74 P to a 74 P. For connecting wires for the winch motors, see mounting of O/OFF, stepless and 0-10 V P RJ12 15º Power and signal for fan Move PE protective earthing from terminal 14 to available terminals without terminal numbers. Internal wires from 74 to 74 P onversion P Remove the 4-core cable. 74 P Figure 10: 74 stepless to 600 LP with splicing sleeves /L 74 Gear Motor and P

17 Technical User Guide Replacing the 74 P Remember to set the jumper on the 74 P. For jumper setting, see section Setting the Jumper. For wiring, see section onnecting Wires in the 74 abinet Using I Rail Terminals () 1) isconnect power to 74. 2)Remove the cover by turning the quarterturn screws (). 3)Remove the motor plug (). () (G) 74 with P (F) () () (E) 4)Remove the screws retaining the P (). 5)Wires retain the old P until the new P has been mounted. 6)Remove the motor (). 7)Mount the 74 P with the screws (). 8)Move one wire at a time from the defective P to the new P's terminal block (E) according to the wiring procedure, see section )Set the jumper to the desired type of 74 (F), see section )Mount the new motor (). (H) L 74 with 8 m gear (F) () 18)Remount the motor plug (); remember to cross the wires when mounting in L 74 with 8 m gear, see picture. 11)onnect power to ) Press the LIRTE button (G). alibrate 74 before calibration of the climate computer. The winch motor / shutter must open completely and then close completely. Meanwhile, the light must be constantly on (H). (E) 13) Remount the cover (). 14) heck whether the fault has disappeared. (G) /L 74 Gear Motor and P

18 18 Technical User Guide PE LIRTE PE LIRTE onnecting Wires in the 74 abinet Using I Rail Terminals O/OFF onnecting wires for the winch motor and fan. When changing the 74 P. O/OFF H10 H11 H12 H13 H14 H15 H1 H2 H3 H6 H7 H8 H9 H 10a 11a H12a O/OFF Figure 11: O/OFF with I rail terminals K O/OFF with External apacitor onnecting wires for the winch motor and fan. When changing the 74 P. O/OFF L H10 H11 H12 H13 H14 H15 Figure 12: O/OFF external capacitor with I rail terminals K H1 H2 H3 H6 H7 H8 H9 H 10a H12a O/OFF /L 74 Gear Motor and P

19 Technical User Guide O/OFF 400 V onnecting wires for the winch motor and fan. When changing a 74 P. PE LIRTE PE LIRTE 400 V L2 L3 400 V L2 L3 H10 H11 H12 H13 H14 H15 H1 H2 H3 H6 H7 H8 H9 H 10a H12a O/OFF 2 14 L3 L2 ontactor K 1 13 W V U Figure 13: O/OFF 400 V with I rail terminals Stepless onnecting wires for the winch motor and fan. When changing a 74 P. * * H10 H11 H12 H13 H14 H15 H1 H2 H3 H6 H7 H8 H9 H 10a 11a H12a /- /- 0-1 Figure 14: Stepless with I rail terminals * Internal Speed ontrol /L 74 Gear Motor and P

20 PE LIRTE PE LIRTE 20 Technical User Guide Stepless with External apacitor onnecting wires for the winch motor and fan. When changing a 74 P. * * L H10 H11 H12 H13 H14 H15 H1 H2 H3 H6 H7 H8 H9 H 10a 11a H12a /- /- 0-1 Figure 15: Stepless external capacitor with I rail terminals * Internal Speed ontrol V onnecting wires for the winch motor. When changing a 74 P. For connecting wires for the fan, see mounting of O/OFF and stepless H10 H11 H12 H13 H1 H2 H3 H6 H7 H8 H9 H 10a 11a H12a Figure 16: 0-10 V winch motor with I rail terminals /L 74 Gear Motor and P

21 Technical User Guide O/OFF to 600 LP-2 without Winch Motor onnecting wires for the 600 LP motor control. When changing a 74 P. For connecting wires for winch motors, see mounting of O/OFF, stepless and 0-10 V 74. Figure 17: 74O O/OFF 600 LP with I rail terminals Stepless to 600 LP-2 without Winch Motor onnecting wires for the 600 LP motor control. When changing a 74 P. For connecting wires for winch motors, see mounting of O/OFF, stepless and 0-10 V 74. Figure 18: 74V stepless to 600 LP with I rail terminals /L 74 Gear Motor and P

22 22 Technical User Guide onnecting Wires in 24 V ontrol Valve for Room Heating Jumper setting. LOG REVERSE onnecting wires from the computer and to the central heating pump. When changing a 74 P Figure 19: 74 P in 24 V control valve /L 74 Gear Motor and P

23 Technical User Guide LE Indication () OK = slow flashing alibration = constantly on Fault = quick flashing Troubleshooting / Remedy Symptom ause Solution The winch motor does not run, the LE does not flash at all. o power supply or power supply below 12 V? Has the motor plug been mounted? Has calibration been forgotten? Has the magnet been mounted? heck supply voltage. heck fuses. heck assembly according to connection and circuit diagram. Mount the plug. Press the LIRTE button; the LE must be constantly on while the winch motor opens and closes. Mount the magnet below the motor P. The LE () flashes quickly 10 times/second. Swivel shutter not fully open / closed. o feedback signal from the house computer. The motor is running in the wrong direction. Table 2: Troubleshooting Has calibration been forgotten? The motor stutters. Has the jumper been set correctly? Is the green gear at 8 m? Press the LIRTE button; the LE must be constantly on while the winch motor opens and closes. Remove any object which may have been trapped in the swivel shutter. Perform a calibration. When using O/OFF 78M, 278M and 378M. onnect Q1 to 4 / 17 / 17 on the main module. Set the jumper according to section ross the motor wires. /L 74 Gear Motor and P

24 SKOV /S Hedelund 4 Glyngøre K-7870 Roslev Tel Fax skov@skov.dk E Made in enmark

DA 74BC Winch Motor. Technical User Guide

DA 74BC Winch Motor. Technical User Guide Technical User Guide English: For other language variants of this document we refer to: Español: Para otras variantes del idioma de este documento, visite: Français: Pour les versions dans d'autres langues

More information

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation Model Installation Instructions Application The Model is designed to add additional control wiring between the thermostat and indoor unit or between the indoor unit and outdoor unit. Before Installing

More information

RECHARGE STATION OPERATION MANUAL. Version

RECHARGE STATION OPERATION MANUAL. Version RECHARGE STATION OPERATION MANUAL Version 1.0-0712 2014 by VirTra Inc. All Rights Reserved. VirTra, the VirTra logo are either registered trademarks or trademarks of VirTra in the United States and/or

More information

4 & 6 Zone 20A Controller Installation And Operating Manual

4 & 6 Zone 20A Controller Installation And Operating Manual UBE 4 & 6 Zone 20A ontroller Installation And Operating Manual Introduction Thank you for purchasing this ube 4 or 6 controller. Whilst the ube has been designed to be as simple as possible to install

More information

EB Conveyor Maintenance Guide

EB Conveyor Maintenance Guide EB Conveyor Maintenance Guide EN-0037 Rev A EB Conveyor Maintenance Guide www.qdraw.com Table of Contents Overview Page 3 Exploded View Of A Standard EB Conveyor Page 4 Preventative Maintenance Page 5

More information

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL : http://www.kutai.com.tw

More information

Measurements are expressed in millimeters.

Measurements are expressed in millimeters. T-Rex user manual Measurements are expressed in millimeters. 1 Lamp access 2 Focus adjustment 3 Mounting bracket 4 Swivel locks 5 Clamp hole 6 Air vent 190 285 7 AC input & main fuse 8 Microphone 490 164

More information

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications POWR MOITORIG ISTLLTIO GUI H81xx H81xx nergy Meter H06 (optional mounting bracket) Installer s Specifications Insulation lass 600V Sample Rate 1280 Hz Internal Isolation 2500V Operating Temp. Range 0 to

More information

For Husqvarna Parts Call 606-678-9623 or 606-61-4983 English 1(7) SB, Auto Mower, Solar Mower, Connectors, 2001-03 1. General Auto Mower and Solar Mower model 2001 are equipped with a different type of

More information

DPS32001 and DPS32PS1

DPS32001 and DPS32PS1 DPS32001 and DPS32PS1 Driver Pack User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

More information

STANDARD AND GROUND SWITCHED APPLICATIONS

STANDARD AND GROUND SWITCHED APPLICATIONS SNOWDOGG LIGHT REFERENCE STANDARD AND GROUND SWITCHED APPLICATIONS GENERAL REFERENCE SNOWDOGG LIGHT REFERENCE GENERAL REFERENCE 3 TROUBLESHOOTING GUIDES/PROCEDURES 6 CONNECTOR REFERENCE 12 ADAPTER HARNESS

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual EasyStart 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro-Air Corporation www.microair.net 124 Route 526 Phone (609) 259-2636 Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information

Technical Data Submittal Document

Technical Data Submittal Document Project: ustomer: ngineer: Pump Manufacturer: Technical ata Submittal ocument Model cross the Line Start lectric ire Pump ontroller ontents: ata Sheets imensional ata Wiring Schematics ield onnections

More information

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control Phone 712.722.4135 groschopp.com 420 15th St NE, Sioux Center, IA 51250 Toll-Free 800.829.4135 Email sales@groschopp.com FAX 712.722.1445

More information

Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520

Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520 USER S MANUAL PORTABLE HIGH CURRENT TEST SET MODEL NUMBER HC2 Version 4.0 Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520 Copyright Phenix Technologies, Inc. Rev 11/20/2014 nab TABLE

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA DPD72001, DPD72002 Unipolar Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

1968 Chevrolet Corvette with & without Factory Air Chevrolet Corvette without Factory Air

1968 Chevrolet Corvette with & without Factory Air Chevrolet Corvette without Factory Air an IS 900:008 Registered ompany 968 hevrolet orvette with & without Factory Air 969-76 hevrolet orvette without Factory Air ontrol Panel onversion Kit (47370) 8865 Goll St. San Antonio, TX 7866 Phone:

More information

Engineered to Ride, Built to last

Engineered to Ride, Built to last Congratulations on your selection to purchase an Arnott Air Suspension System. We at Arnott Air Suspension Systems are proud to offer a high quality product at the industries most competitive pricing.

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

SOFT TOUCH for PNEUMATIC RIVETERS

SOFT TOUCH for PNEUMATIC RIVETERS SOFT TOUCH for PNEUMATIC RIVETERS 9181-34YM/115 RIVET 9181-34YM/230 RIVET UNITROL ELECTRONICS, INC. 702 LANDWEHR ROAD NORTHBROOK, IL 60062 847-480-0115 techsupport@unitrol-electronics.com 1 2 MODEL: 9181-34YM-RIVET/115

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

- Wiring Brochure Universal Reset Module 422

- Wiring Brochure Universal Reset Module 422 - Wiring Brochure Universal Reset Module 422 W 422 03/09 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION Thank you for purchasing the CMD-4000 series Remote Control Door Latch Opener System from Dakota Digital, Inc. This,

More information

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

ODY-05-2 VOLTMETER FOR REMOTE MONITORING ODY-05-2 VOLTMETER FOR REMOTE MONITORING Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 120L4060, LF151200W4

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 120L4060, LF151200W4 External us Resistor Kit for LiquiFlo Drives Drive M/N s 120L4060, LF151200W4 Instruction Manual D2-3537!!!!! TTENTION: Only qualified electrical personnel familiar with the construction and operation

More information

HAT220A ATS CONTROLLER USERS MANUAL

HAT220A ATS CONTROLLER USERS MANUAL HAT220A ATS CONTROLLER USERS MANUAL Smartgen Technology Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou Henan Province

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU) INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU) Model Number: 41756 (100 125Vac) 41757 (220 240Vac) Manufactured in the United Kingdom CONTENTS Chapter Page Specification 3 What the TAU does

More information

2.2.3 Mounting of climate sensors

2.2.3 Mounting of climate sensors Page 10 2.2.3 Mounting of climate sensors The indoor temperature and humidity sensors should be placed: 1 m above the zone occupied by the animals, near the middle of the house. in draught-free zone, not

More information

Installation and Maintenancee Manual

Installation and Maintenancee Manual Installation and Maintenancee Manual Commercial Boom Gate Operator Model: GDS BOOM 4 and 6 A.B.N. 62 059 806 405 Nov 2013 Section No: CONTENTS Page Number: 1 Safety Precautions 3 2 Specifications 4 3 Mechanical

More information

GREENSTAR CANTIELEVER. User Guide. v4 - English

GREENSTAR CANTIELEVER. User Guide. v4 - English GREENSTAR CANTIELEVER User Guide v4 - English Content 1 General Information 1.1 Greenstar 1.2 Objective 1.3 Copyrigth 1.4 Safety 2 Technical Information 2.1 Mounting 2.1.1 Functions 2.1.2 Nomenclature

More information

VIESMANN. Installation instructions VITOTROL 100. for contractors. Vitotrol 100 Type UTDB

VIESMANN. Installation instructions VITOTROL 100. for contractors. Vitotrol 100 Type UTDB Installation instructions for contractors VIESMNN Vitotrol 100 Type UTD Room temperature controller with digital time switch Part no: 7426 465, 7426 538 VITOTROL 100 7/2009 Safety instructions Please follow

More information

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION Thank you for purchasing the CMD-4000 series Remote Control Door Latch Opener System from Dakota Digital, Inc. This,

More information

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2 Operators Manual SUREFIRE II Single Phase PDI - SLR (24VD, 115VA & 230VA) 36412 r#2 ontents Precautions & Symbols...2 Manufacturer s Statement...2 General...2 Features...2 Operation...3-4 Technical Data...5

More information

K001A6039. Control Board Replacement Kit WARNING INSTALLATION INSTRUCTIONS APPLICATION REQUIREMENTS: FUNCTION: REMOVE EXISTING BOARD

K001A6039. Control Board Replacement Kit WARNING INSTALLATION INSTRUCTIONS APPLICATION REQUIREMENTS: FUNCTION: REMOVE EXISTING BOARD ontrol Board Replacement Kit APPLIATI REQUIREMENTS: This modification is available to all LA400 North American gate operators. FUTI: Allows existing LA400 control board in the field to be replaced or upgraded

More information

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website: BLHV, BLHV-1 High Voltage Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com #L010015 (714) 992-6990 fax: (714)

More information

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control Phone 712.722.4135 groschopp.com 420 15th St NE, Sioux Center, IA 51250 Toll-Free 800.829.4135 Email sales@groschopp.com FAX 712.722.1445

More information

DUSK-TO-DAWN LIGHT MODEL #GU8813-BZ-I, #GU8813-WH-I

DUSK-TO-DAWN LIGHT MODEL #GU8813-BZ-I, #GU8813-WH-I ITEM #0333554, #0333553 DUSK-TO-DWN LIGHT MODEL #GU8813-BZ-I, #GU8813-WH-I Utilitech & UT Design and Grounded in Quality are registered trademarks of LF, LL. ll Rights Reserved. Français p. 7 Español p.

More information

OWNER S MANUAL MODEL: PT 450 / PT 450M WELDING POSITIONER

OWNER S MANUAL MODEL: PT 450 / PT 450M WELDING POSITIONER OWNER S MANUAL RD-8450E Important Read these instructions before installing, operating or servicing this product. MODEL: PT 450 / PT 450M WELDING POSITIONER Serial number 1506003 ~ and later Revised date

More information

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81)

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81) WEB CONTROL PRODUCTS User Manual Signal Conditioner SC100 FORM NO. L-63-B-0304 1 FORM NO. L-63-B-0304 In accordance with Nexen s established policy of constant product improvement, the specifications contained

More information

ODY-19-1 AIR PRESSURE GAUGE

ODY-19-1 AIR PRESSURE GAUGE ODY-19-1 AIR PRESSURE GAUGE Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features and easy

More information

Operating Instructions

Operating Instructions Operating Instructions Quadax Series Butterfly Valves (with actuator) Version September 2009 müller co-ax ag Gottfried-Müller-Str. 1 74670 Forchtenberg Germany Tel. +49 7947 828-0 Fax +49 7947 828-11 E-Mail

More information

Troubleshooting Manual

Troubleshooting Manual Troubleshooting Manual NOTICE: DO NOT DISCARD THIS MANUAL Models: LEGACY42-IFT PHOENIX42-IFT 1 TABLE OF CONTENTS A. Normal Operation...3 B. Wiring Diagram...4 C. Troubleshooting IntelliFire Touch...5 D.

More information

HLY-1111 HEAD TEMPERATURE GAUGE

HLY-1111 HEAD TEMPERATURE GAUGE HLY-1111 HEAD TEMPERATURE GAUGE Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features and

More information

R231 A.V.R. Installation and maintenance R 231. This manual is to be given to. the end user. Armature 6- Field. Slow-blow fuse 250V 8 A

R231 A.V.R. Installation and maintenance R 231. This manual is to be given to. the end user. Armature 6- Field. Slow-blow fuse 250V 8 A Armature 6- Field This manual is to be given to the end user F1 Slow-blow fuse 250V 8 A 110 0V E+ E- 75 mm 140 mm P1 P2 Voltage Stability R 231 This manual concerns the alternator which you have just purchased.

More information

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth RCL-7A Battery Charging Station User s Guide Technology in Depth - NOTICE - This manual and the information contained herein are provided for use as a maintenance and operation guide. No license or rights

More information

********SERVICE MANUAL********* MODELS:

********SERVICE MANUAL********* MODELS: ********SERVICE MANUAL********* MODELS: -------------- 7553-70 Variable Speed Drive/Controller System, 600 rpm, 115v 7553-71 Variable Speed Controller only, 600 rpm,115v 7553-80 Variable Speed Drive/Controller

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Index. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led

Index. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led MANUAL Micro Driver Via Ilaria Alpi N 6 - zona industriale - Lonato (BS) Tel. 030/9913491r.a. Fax. 030/9913504 http://www.re-elettronica.it E-mail : info@re-elettronica.it Pag. 1 Index Index........pag.1

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

XR Conveyor Maintenance Guide

XR Conveyor Maintenance Guide XR Conveyor Maintenance Guide EN-0035 Rev. A XR Conveyor Maintenance Guide www.qdraw.com Table of Contents 05/20/2009 Overview Page 3 XR Conveyor Assembly Page 4 General Information Exploded View of an

More information

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US Introduction This manual pertains to drum pump motors MV Series. Finish Thompson, Inc. thanks you for choosing our products. We believe

More information

Service Jacks. No. 1503A Max. Capacity: 2-1/2 Tons No. 1504A Max. Capacity: 3 Tons. Service Jack Item List

Service Jacks. No. 1503A Max. Capacity: 2-1/2 Tons No. 1504A Max. Capacity: 3 Tons. Service Jack Item List SPX Corporation 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales:

More information

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol DC Motor Speed Control Boston Gear Ratiotrol DC Motor Speed Control P-3017-BG Doc. No. 60007 Installation and Operation DCX plus Series II Enclosed Models 1/12-1 HP a division of Altra Industrial Motion Contents l General Information

More information

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier Operation and Maintenance Instructions Manual BOOSTER Volume amplifier 1. GENERAL INFORMATION... 3 2. TECHNICAL SPECIFICATIONS... 3 3. DIMENSIONAL DESIGN... 4 3.1 BOOSTER WITHOUT SIGNAL ADAPTER... 4 3.2

More information

DensFlow D. Superior with Solids. Flow measurement for densphase conveying. Operating Instructions

DensFlow D. Superior with Solids. Flow measurement for densphase conveying. Operating Instructions EN Operating Instructions DensFlow D Flow measurement for densphase conveying SWR engineering Messtechnik GmbH PART OF THE ENVIRONNEMENT S.A GROUP ontents Page 1. System overview.............................................

More information

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power Page 1 of 8 equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after waste water source has been connected to system. WARNING: Risk of Asphyxiation. Installer(s)

More information

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System The Power Systems Industry Experts Installation Instructions PT100 Stationary Generator Monitoring System PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLATION Planning the Installation The monitoring unit

More information

Mini Jacks Instruction Manual

Mini Jacks Instruction Manual J11050-M0_062017 Instruction Manual MODELS: J11050, J11055-5 Ton Capacity J11100-10 Ton Capacity J11200-20 Ton Capacity This is the safety alert symbol. It is used to alert you to potential personal injury

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has

More information

HCV-5HA 7.2kV, 400A-7.0kA HCV-5HAL 7.2kV, 400A-7.0kA

HCV-5HA 7.2kV, 400A-7.0kA HCV-5HAL 7.2kV, 400A-7.0kA Document: VF00W103 Rev. 7 INSTRUCTION MANUAL INSTALLATION - OPERATION - MAINTENANCE HCV-5HA 7.2kV, 400A-7.0kA (4.5kA@7.2kV) HCV-5HAL 7.2kV, 400A-7.0kA (4.5kA@7.2kV) Manufactured in the USA MAY 2008 MAY

More information

English. Instruction and operation manual S 212. Dew point sensor

English. Instruction and operation manual S 212. Dew point sensor English Instruction and operation manual S 212 Dew point sensor Dear Customer, thank you for choosing our product. The operating instructions must be read in full and carefully observed before starting

More information

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and AVTM220003 Rev. B January 2003 Instruction Manual AVTM220003 for DC µa Strip Chart Recorder Catalog Nos. 220003 and 220003-47 PO Box 9007 Valley Forge, PA 19485-1007 U.S.A. 610-676-8500 Shipping Address:

More information

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3 EUROTHERM DRIVES Control Unit Type 5525 Product Manual Copyright Eurotherm Drives Limited 2003 All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted

More information

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website: DPBHV001, DPZHV002 High Voltage Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA MDC150-012301 12V, 30A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

LED SEMI-FLUSHMOUNT CEILING FIXTURE

LED SEMI-FLUSHMOUNT CEILING FIXTURE ITEM #0760102 LED SEMI-FLUSHMOUNT EILING FIXTURE MODEL #SFL11BNK Français p. 9 Español p. 17 TTH YOUR REEIPT HERE Serial Number Purchase Date E465631 Questions, problems, missing parts? Before returning

More information

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED.

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED. Manual STEPPER-BLOCKplus &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV Main Status-LED Current Adjustment Controller Motor Version: 2.0 As of: 06/2002 Author: Edmund Burger All rights reserved: MOTRON Steuersysteme

More information

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017 Operator s Manual Fairbanks FH Series 2017 by Fairbanks Scales, Inc. All rights reserved 51393. Revision 1 06/2017 Amendment Record Fairbanks FH Series Operator s Manual Operator s Manual Document 51393

More information

Installation Manual Model 3800/3810

Installation Manual Model 3800/3810 Installation Manual Model 3800/3810 Thermistors & Thermistor Strings No part of this instruction manual may be reproduced, by any means, without the written consent of Geokon, Inc. The information contained

More information

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060 TM4500 Track Mounted Step Motor Driver User s Guide CE Certified and RoHS Compliant A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990

More information

Expansion Signal (XSIG) Card Installation Instructions

Expansion Signal (XSIG) Card Installation Instructions Expansion Signal (XSIG) Card Installation Instructions Introduction This publication describes the installation procedure for the Expansion Signal (XSIG) Card (4100-5116). This product is compatible with

More information

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide ICM325HN Head Pressure Control with Optional Heat Pump Override Temperature sensitive control regulates head pressure Installation, Operation & Application Guide For more information on our complete range

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

Turn Signal Kit Installation Instructions for Model A Fords & Other Antique Vehicles

Turn Signal Kit Installation Instructions for Model A Fords & Other Antique Vehicles Turn Signal Kit Installation Instructions for Model A Fords & Other Antique Vehicles Lifetime Technical Support support@logolites.com 770-476-7322 www.logolites.com Manual 100-0005N Thank you for purchasing

More information

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

User Manual Industrial Power Storage System (ips) ips-m Series Battery System User Manual Industrial Power Storage System (ips) ips-m Series Battery System Copyright The documentation and the software included with this product are copyrighted 2011 by Advantech Co., Ltd. All rights

More information

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx External us Resistor Kit for LiquiFlo Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx Instruction Manual D2-3538!!!!! TTENTION: Only qualified electrical personnel familiar with the

More information

SOFT TOUCH FOR PNEUMATIC RIVETERS

SOFT TOUCH FOR PNEUMATIC RIVETERS SOFT TOUCH FOR PNEUMATIC RIVETERS RST300-115-RIVET (115VAC) RST300-230-RIVET (230VAC) Distributed by: MODEL: RST300-115-RIVET (115VAC) RST300-230-RIVET (230VAC) OPTIONS: RST-403 RST-404 SERIAL NUMBER:

More information

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3) Door Control Board: Board 1Ø4 for PM/SSC 61111-149 (R3) 2000-08-31 2000, 1992 KONE Inc. Unpublished work. All rights reserved. No portion of this volume may be used or reproduced in any manner without

More information

MDC Series

MDC Series MDC151-050101 Series 50V, 10A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

Fault Code 16: Eaton Proprietary Link (EPL)

Fault Code 16: Eaton Proprietary Link (EPL) ault ode 16: aton Proprietary Link (PL) ault Isolation Procedure ault ode 16: aton Proprietary Link (PL) 1587:MI 130 SI 248 MI 2 Overview ault ode 16 indicates the Shift ontroller and the Transmission

More information

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual Pull Side Applications with Slide Track (7210, 7250) (see page 7 for template) 7200 Series Multi-Point Hold Open Installation and Instruction Manual 3 1 Push Side Applications with Double Lever Arms (7220,

More information

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation 2 Exterior Digital Load Scale 201-EDG-01(B) Table of Contents Specifications & Overview

More information

MODEL SMZ-SW ZONE CONTROL SYSTEM

MODEL SMZ-SW ZONE CONTROL SYSTEM DuroZone MODEL SMZ-SW ZONE ONTROL SYSTEM DuroZone is a division of orporation PART# 35226 PART# 35227 SMZ-2SW/SMZ-3SW INSTALLATION INSTRUTIONS ongratulations on purchasing a DuroZone SMZ ontrol System.

More information

Air Actuated Hydraulic Bottle Jack on Wheels

Air Actuated Hydraulic Bottle Jack on Wheels Operating Instructions & Parts Manual Air Actuated Hydraulic Bottle Jack on Wheels Model Number 18127 18207 Capacity 12 Ton 20 Ton Shinn Fu Co. of America, Inc. 2002 10939 N. Pomona Avenue Kansas City,

More information

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners using Installation Kit KIT-364-CM1 Contents Introduction... 2 Safety first... 2 Making a good crimp...

More information

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA MDC2-2451 11VAC Input Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 9287 e-mail: info@anaheimautomation.com (714) 992-699 fax: (714) 992-471 website:

More information

ROTARY HEAD DIGITAL STEM THERMOMETER

ROTARY HEAD DIGITAL STEM THERMOMETER ROTARY HEAD DIGITAL STEM THERMOMETER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com DT340RH Please read this manual carefully

More information

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever. Safety Precautions This product complies with the requirements of the following European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) as amended by 2004/22/EC

More information

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA BLDPN30001 Series 30A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N OPERATING & MAINTENANCE INSTRUCTIONS 1206 SPECIFICATIONS Supply Voltage 230 Max Charge (Amps) 60 (cont) Max Boost (Amps) 400 Boost/Charge (Volts)

More information

Co-pilot Owner s manual

Co-pilot Owner s manual Attendant controller Co-pilot Owner s manual US How to contact Permobil Permobil Inc. USA 6961 Eastgate Blvd. Lebanon, TN 37090 USA Phone: 800-736-0925 Fax: 800-231-3256 Email: info@permobilus.com Head

More information

Digital Pressure Regulator Sentronic PLUS Series 614

Digital Pressure Regulator Sentronic PLUS Series 614 Digital Pressure Regulator Sentronic PLUS Series 14 Installation manual IM149-/R01 CONTENTS 1. Description... 1.1 Catalogue number... 1. Operating elements...4 1. Operating modes...4. Electrical connection...5.

More information

AL-KO ESC USER MANUAL

AL-KO ESC USER MANUAL Vehicle Technology QUALITY FOR LIFE AL-KO ESC USER MANUAL OPERATING INSTRUCTIONS WARRANTY DETAIL About AL-KO ESC The new AL-KO ESC (Electronic Stability Control) is a sway and swerve stability control

More information

HLS Watt Halogen Illuminator Service Manual

HLS Watt Halogen Illuminator Service Manual HLS-150 150-Watt Halogen Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 737 7611 FAX 904 733 4832 Toll Free 877 677 2832 (English) TABLE OF CONTENTS Page

More information

Rain Gauge Smart Sensor (Part # RGA-M0XX, RGB-M0XX)

Rain Gauge Smart Sensor (Part # RGA-M0XX, RGB-M0XX) (Part # RGA-M0XX, RGB-M0XX) The Rain Gauge smart sensor is designed to work with the HOBO Weather Station logger. The smart sensor has a plug-in modular connector that allows it to be added easily to a

More information