HOW TO SPECIFY SDV UNITS
|
|
- Evelyn Cunningham
- 5 years ago
- Views:
Transcription
1 HOW TO SPECIFY SDV UNITS MODEL UNIT CONFIG LINER CASING OPTIONS CONST. SIDE INLET SIZE DISCHARGE OPTIONS CONTROL TYPE UNIT ACCESSORIES HEAT kw ELECTRIC HEAT ACCESSORIES SCR HEAT ACCESSORIES SDV 0 - Standard Construction (no electric heat or attenuator) 1 - Attenuator 3 - Electric Heat 0-1/2 Dual Density Lining 1-1 Dual Density Lining 2 - Insul-Guard (13/16 Rigid Duct Board) 3 - No Liner 4 - Galvanized Sheet Metal Liner 5 - Enviroseal (fiber free) 0-22 Gauge 1-22 Gauge w/ Access Doors 2-20 Gauge 3-20 Gauge w/ Access Doors 5-22 Gauge w/ Access Doors (Cam Lock Fasteners) 6-20 Gauge w/ Access Doors (Cam Lock Fasteners) R - Right L - Left } Controls & Damper Side 04 - Inlet Size 4 (Reducer) 10 - Inlet Size Inlet Size 5 (Reducer) 12 - Inlet Size Inlet Size Inlet Size Inlet Size Inlet Size Inlet Size Inlet Size Standard Rectangular F - 5 (8 ) 1 - One Round Outlet G - 2 (10 ) A - 2 (6 ) H - 3 (10 ) B - 3 (6 ) J - 4 (10 ) C - 2 (8 ) K - 5 (10 ) D - 3 (8 ) L - 2 (12 ) E - 4 (8 ) M - 3 (12 ) None Electric Heat E/C11 - E13 (120V / 1φ) E/C21 - E23 (208V / 1φ) E/C31 - E33 (240V / 1φ) E/C41 - E43 (277V / 1φ) E/C61 - E63 (208V / 3φ) E/C91 - E93 (480V / 3φ) - 4 Wire 0 - None A - Chicago Code D - Controls Disconnect Switch (toggle) E - Dust-Tight Sealing for Control Enclosure G - 24V / 24V Transformer H - 120V / 24V Transformer J - 208V / 24V Transformer K - 240V / 24V Transformer L - 277V / 24V Transformer S - Hanger Brackets 0 - None B - Mercury Contactor C - Fusing K - Fused Door Interlocking Disconnect Switch L - Non-Fused Door Interlocking Disconnect Switch No Controls/No Control Enclosure Analog Pneumatic Digital - Contact Application Engineer For Field Mounted Controls w/ Control Enclosure: Analog/DDC - DFMT 0 - None F - Fusing D - Door Interlocking Disconnect Switch P - Pneumatic Heater Hot Water Heat W11 - Right Hand, 1 row W12 - Right Hand, 2 row W13 - Right Hand, 3 row W14 - Right Hand, 4 row W21 - Left Hand, 1 row W22 - Left Hand, 2 row W23 - Left Hand, 3 row W24 - Left Hand, 4 row SD -3 * PLEASE SEE NOTES PAGES FOR EXPLANATIONS OF ALL OPTIONS
2 Notes This page has intentionally been left blank. SD - 4
3 LIST PRICES MODEL: SDV SDV Single Duct Terminal Unit Unit Config, Lining, Casing & Discharge Options Casing Sizes 4, 5, 6 7, Base Price - Standard Construction (No Electric Heat or Attenuator) (0) Unit Configuration Attenuator (1) Electric Heat (3) (refer to page SDV-7 for list add) Subtotal for Unit Configuration 1/2 Dual Density Fiberglass (0) 1 Dual Density Fiberglass (1) Insul-guard TM (2) No Liner (3) Galvanized Sheet Metal (4) (1/2 Double Wall) Enviroseal TM (5) Lining Options Basic Unit Basic Unit w/ Discharge Attn. or Electric Reheat Basic Unit Basic Unit w/ Discharge Attn. or Electric Reheat Basic Unit Basic Unit w/ Discharge Attn. or Electric Reheat Basic Unit Basic Unit w/ Discharge Attn. or Electric Reheat Basic Unit Basic Unit w/ Discharge Attn. or Electric Reheat Basic Unit Basic Unit w/ Discharge Attn. or Electric Reheat Perforated Sheet Metal (Double Wall) Subtotal for Lining Options Contact Tuttle & Bailey Casing Options 22 Gauge (0) Gauge w/ Access doors (1) Gauge (2) Gauge w/ Access doors (3) Gauge w/ Access doors w/ Cam Lock Fasteners (5) Gauge w/ Access doors w/ Cam Lock Fasteners (6) Subtotal for Casing Options Effective Date 07/08 CFM without Electric Heat or with Hot Water Heat Size Min CFM Max CFM SD-5
4 Control Type & Unit Accessories List Prices MODEL: SDV Discharge Options Standard Rectangular (0) One Round Discharge (1) Two (2) 6" Round Discharges (A) Three (3) 6" Round Discharges (B) Two (2) 8" Round Discharges (C) Three (3) 8" Round Discharges (D) Four (4) 8" Round Discharges (E) Five (5) 8" Round Discharges (F) Two (2) 10" Round Discharges (G) Three (3) 10" Round Discharges (H) Four (4) 10" Round Discharges (J) Five (5) 10" Round Discharges (K) Two (2) 12" Round Discharges (L) Three (3) 12" Round Discharges (M) Subtotal for Discharge Options Casing Sizes 4, 5, 6 7, Pneumatic Analog FMA Control Type 0000: No Controls/No Control Enclosures 1200: DA/NO Dual Min : DA/DO Dual Max 1202: DA/NO : RA/NO : DA/NC : RA/NC 2200: Analog Cooling 2201: Analog Cooling w/ Auto Change Over 2202: Analog Cooling w/ Electric Heat 2203:Analog Cooling W/ Hot Water Heat Factory Mounting Field Mounting (PFMT/DFMT) Subtotal for Control Type Unit Accessories Chicago Code (A) Controls Disconnect Switch (D) Dust Tight Sealing for Control Enclosure (E) 24V/24V Transformer (G) 120V/24V Transformer (H) 208V/24V Transformer (J) 240V/24V Transformer (K) 277V/24V Transformer (L) Hanger Brackets (S) Subtotal for Unit Accessories SD - 6
5 Electric & Hot Water Heat List Prices Hot Water MODEL: SDV Heat 1Row(W11/W21) 2Row(W12/W22) 3Row(W13/W23) 4Row(W14/W24) Subtotal for Hot Water Heat Casing Sizes 4, 5, 6 7, E L E C T R I C H E A T S T A N D A R D S C R kw E11, E21, E31, E kw kw kw E12, E22, E32, E kw kw kw E13, E23, E33, E kw kw kw E61, E kw kw kw E62, E kw kw kw E63, E kw kw Subtotal for Standard Electric Heat C11 C21 C31 C41 C61 C91 Subtotal for SCR Electric Heat See page SD-9 for available kw Ranges. Standard Pneumatic Heater list add $40 SCR Pneumatic Heater (P) list add $ kw kw kw kw kw kw kw kw kw kw kw ,190 1,190 1,190 1,190 1,190 1,190 1,190 1,429 1,429 1,429 1,429 1,429 1,429 1,429 1,190 1,190 1,190 1,190 1,190 1,190 1,190 1,429 1,429 1,429 1,429 1,429 1,429 1,429 SD - 7
6 Electric and SCR Heat Accessories MODEL: SDV List Prices Casing Sizes 4, 5, 6 7, Electric Heat Coil Accessories E11, E21, E31, E kw kw kw E12, E22, E32, E42 Mercury Contactor (B) kw E13, E23, E33, E kw kw E61-E63, E91-E93 All kw Fusing (C) All Single Phase Voltages All kw All Three Phase Voltages All kw All Single Phase Voltages kw Fused Door Interlocking All Single Phase Voltages kw Disconnect Switch (K) All Three Phase Voltages All kw Non-Fused Door Interlocking Disconnect Switch (L) All Phases and Voltages All kw Subtotal for Electric Heat Coil Accessories MODEL: SDV Casing Sizes 4, 5, 6 7, SCR Heat Accessories Fusing (F) All Single Phase Voltages All kw All Three Phase Voltages All kw Door Interlocking Disconnect Switch (D) All Phases and Voltages All kw Pneumatic Heater (P) All Phases and Voltages All kw Subtotal for SCR Heat Accessories SD - 8
7 Electric Heat Ranges List Prices g ( ) ELECTRIC HEAT RANGES (kw) Size E11 E12 E13 Size E21 E22 E23 Size E31 E32 E Size E41 E42 E43 Size E61 E62 E63 Size E91 E92 E SCR Heater kw Ranges Size Base Unit CFM SCR Heater Codes C11 C21 C31 C41 C61 C CFM RANGES CFM w/ Electric Heat Size Min CFM Max CFM SD - 9
8 SDV Single Duct Terminal Unit General Notes on How To Specify STANDARD FEATURES Patented Flo-Cross Sensor which features 24 point upstream and downstream sensing with center averaging chambers and exclusive amplification wings (Patent # 4,453,419) Industry standard round inlet collars sized to accept either flexible or rigid duct Round damper blade constructed of elastomeric gasket sandwiched between two heavy-duty galvanized steel plates Damper shaft with Delrin bearings. Shaft features a position indicator for easy identification of damper angle Slip and Drive connection on the discharge plenum Flo-Cross Sensor balancing curve label Fire rated pneumatic tubing comes on all units UNIT CONFIGURATION Standard Construction (0) - This configuration is used with a No Heat or Hot Water Heat option. This option does not include an attenuator. Attenuator (1) - This configuration is used with a No Heat or Hot Water Heat option. It is a integral attenuator. Electric Heat (3) - This configuration is required for Electric Heat. It cannot be used with No Heat or Hot Water Heat. The Electric Heat configuration comes standard with the integral attenuator. List add for electric heat is incorporated in the Electric Heat pricing. Not compatible with access doors. LINER 1/2 Dual Density Lining (0) - 1/2 thick fibrous glass blanket with a black top layer and a green core. Complies with NFPA 90A, NFPA 90B, UL 181 and ASTM C R value at 75ºF is This insulation is glued to the terminal unit. 1 Dual Density Lining (1) - 1 thick fibrous glass blanket with a black top layer and a green core. Complies with NFPA 90A, NFPA 90B, UL 181 and ASTM C R value at 75ºF is This insulation is glued to the terminal unit. Insul-Guard (2) - 1 Rigid Duct Board, resin bonded fibrous glass board, with a tough, damage-resistant, flame retardant, reinforced aluminum foil facing. Complies with NFPA 90A, NFPA 90B, UL 181 and UL723. R value at 75ºF is This insulation is glued to the terminal unit and secured by Z strips at the ends. No Liner (3) - No insulation. Notes Galvanized Sheet Metal (4) - 1/2 Double Wall, dual density lining with a piece of sheet metal covering the entire liner. Not compatible with Cam Lock Access Doors. Standard Access Door casing options 1 and 3 are available. It is compatible with a discharge attenuator and electric heat. This insulation is glued to the terminal unit and secured by Z strips at the ends. Enviroseal (5) - 3/8 Engineered Polymer Foam Insulation, fiber free insulation. Complies with NFPA 90A, NFPA 90B, UL 181 and ASTM C 534. R value at 75ºF is 4. This insulation is glued to the terminal unit and mechanically fastened by rivets to the terminal unit casing. Not compatible with electric heat. CASING OPTIONS Construction 22 Gauge (0) - The construction of the terminal unit uses 22-gauge sheet metal. 22 Gauge w/ Access Door (1) - The construction of the terminal unit uses 22-gauge sheet metal with an access door mounted to the bottom of the terminal unit secured by screws. Not compatible with Electric Heat. Not avavailable on size 24 with standard construction unit configuration. 20 Gauge (2) - The construction of the terminal unit uses 20-gauge sheet metal. 20 Gauge w/ Access Door (3) - The construction of the terminal unit uses 20-gauge sheet metal with an access door mounted to the bottom of the terminal unit secured by screws. Not compatible with Electric Heat. Not avavailable on size 24 with standard construction unit configuration. 22 Gauge w/ Access Door (Cam Lock Fasteners) (5) - The construction of the terminal unit uses 22-gauge sheet metal with an access door mounted to the bottom of the terminal unit secured by Cam Lock Fasteners. Not compatible with Galvanized Sheet Metal Liner, Electric Heat, or Size Gauge w/ Access Door (Cam Lock Fasteners) (6) - The construction of the terminal unit uses 20-gauge sheet metal with an access door mounted to the bottom of the terminal unit secured by Cam Lock Fasteners. Not compatible with Galvanized Sheet Metal Liner, Electric Heat, or Size 24. SD-10 Effective Date 07/08
9 General Notes on How to Specify Notes DAMPER/CONTROL LOCATION Right (R) - Controls and damper shaft are located on the right hand side of the terminal unit. If you are looking at the inlet of the terminal unit, and the primary air is hitting you in the back of the head, then your right is the right hand of the terminal unit. Left (L) - Controls and damper shaft are located on the left hand side of the terminal unit. If you are looking at the inlet of the terminal unit, and the primary air is hitting you in the back of the head, then your left is the left hand of the terminal unit. INLET SIZE 04 - Inlet diameter of 4 inches (actual size is 3-7/8"), 6" to 4" reducer is used for this size 05 - Inlet diameter of 5 inches (actual size is 4-7/8"), 6" to 5" reducer is used for this size 06 - Inlet diameter of 6 inches (actual size is 5-7/8") 07 - Inlet diameter of 7 inches (actual size is 6-7/8") 08 - Inlet diameter of 8 inches (actual size is 7-7/8") 10 - Inlet diameter of 10 inches (actual size is 9-7/8") 12 - Inlet diameter of 12 inches (actual size is 11-7/8") 14 - Inlet diameter of 14 inches (actual size is 13-7/8") 16 - Inlet diameter of 16 inches (actual size is 15-7/8") 24 - Inlet diameter of 24x16 inches, rectangular (actual size is 23-7/8" x 15-7/8") DISCHARGE OPTIONS (No Slip and Drive) Standard Rectangular (0) - Standard rectangular outlet with Slip and Drive connections One Round Outlet (1) - Round outlet that matches the inlet size. No Slip and Drive (not available for size 24) Two 6" Outlets (A) - Two 6" round outlets, only available with sizes 4, 5 and 6 Three 6" Outlets (B) - Three 6" round outlets, only available with sizes 4, 5 and 6 Two 8" Outlets (C) - Two 8" round outlets, only available with sizes 7 and 8 Three 8" Outlets (D) - Three 8" round outlets, only available with sizes 7, 8 and 10 Four 8" Outlets (E) - Four 8" round outlets, only available with sizes 7, 8 and 10 Five 8" Outlets (F) - Five 8" round outlets, only available with size 8 Two 10" Outlets (G) - Two 10" round outlets, only available with size 10 Three 10" Outlets (H) - Three 10" round outlets, only available with sizes 10, 12, 14 and 16 Four 10" Outlets (J) - Four 10" round outlets, only available with sizes 10, 12, 14 and 16 Five 10" Outlets (K) - Five 10" round outlets, only available with sizes 12, 14 and 16 Two 12" Outlets (L) - Two 12" round outlets, only available with sizes 12, 14 and 16 Three 12" Outlets (M) - Three 12" round outlets, only available with sizes 12, 14 and 16 CONTROL TYPE No Controls (0000) Components Supplied: Pneumatic Tubing Compatible with: Reheat Type: Hot Water Heat Reheat Type: No Heat Reheat Type: Electric Heat Unit Accessories: Controls Disconnect Switch (D) Unit Accessories: Dust Tight Sealing for Control Enclosure (E) Unit Accessories: Transformers (any voltage) This control sequence does not come with a control enclosure or balancing tees. SD - 11
10 General Notes on How to Specify Notes Pneumatic Controls Components supplied on all Pneumatic Control Sequences: KMC Four Function Pneumatic Controllers (CSC-3011) KMC Pneumatic Actuators (MCP-8031) Balancing Tees Pneumatic Tubing Compatible with: Reheat Type: No Heat Reheat Type: Hot Water Heat Reheat Type: Electric Heat Unit Accessories: Controls Disconnect Switch (D) Unit Accessories: Dust Tight Sealing for Control Enclosure (E) Unit Accessories: Transformers (any voltage, unless Electric Heat is selected) Pneumatic Controls are not supplied with a thermostat from T&B, thermostats must be supplied by others in the field. All Pneumatic Controls are piped by T&B and will be calibrated by T&B if any CFM on the order is greater than 0. No control enclosure supplied unless Electric Heat is selected Direct Acting (DA) Normally Open (NO) Dual Minimum Control Sequence comes with a High Pressure Selector (KMC model RCC-1108) and a Pressure Regulator Valve (KMC Model RCC-1112). The High Pressure Selector switches the controller between the primary minimum and the secondary minimum. The Pressure Regulator Valve receives a signal from a secondary main line, with a pressure signal of 0 psig for cooling mode and a pressure signal of 15 psig for heating mode, to tell the high pressure selector which minimum to use Direct Acting (DA) Normally Open (NO) Dual Maximum Control Sequence comes with High Pressure Selectors (KMC model RCC-1108) and two Pressure Regulator Valves (KMC Model RCC-1112). The High Pressure Selector switches the controller between the primary maximum and the secondary maximum. The Pressure Regulator Valves receives a signal from the thermostat, a pressure signal of 3 psig or less to tell the high pressure selector which maximum to use Direct Acting (DA) Normally Open (NO) Reverse Acting (RA) Normally Open (NO) Direct Acting (DA) Normally Closed (NC) Reverse Acting (RA) Normally Closed (NC) SD - 12
11 General Notes on How to Specify Notes Analog Controls Components supplied on all Analog Control Sequences: Control Enclosure (NEMA 1) KMC Analog Controller/Actuator (CSP-5001) KMC Analog Thermostat (see control sequence for exact model number) Pneumatic Tubing Balancing Tees Compatible with: Unit Accessories: Controls Disconnect Switch (D) (except for 2202) Unit Accessories: Dust Tight Sealing for Control Enclosure (E) Unit Accessories: Transformers (except when Electric Heat is selected, then the transformer is included w/ Electric Heat) All Analog Controls are piped and wired by T&B, and will be calibrated by T&B if any CFM on the order is greater than 0. Transformers are not a supplied as standard on Analog Control Sequences. They must be selected from the Unit Accessories, if required Cooling only control sequence comes with a KMC Thermostat CTE This sequence is only available with the reheat type of No Heat Cooling only with Auto Changeover control sequence comes with a KMC Thermostat CTE-5103 and a KMC Changeover Duct Sensor STE This sequence is only available with the reheat type of No Heat Cooling with Electric Heat control sequence comes with a KMC Thermostat CTE-5104 and a KMC Reheat Relay Module REE This sequence is only available with the reheat type of Electric Heat Cooling with Hot Water Heat control sequence comes with a KMC Thermostat CTE-5104 and a KMC Reheat Relay Module REE This sequence is only available with the reheat type of Hot Water Heat. FMA Controls Components supplied on all FMA Control Sequences: Control Enclosure (NEMA 1) Pneumatic Tubing Compatible with: Unit Accessories: Controls Disconnect Switch (D) (except when Electric Heat is selected) Unit Accessories: Dust Tight Sealing for Control Enclosure (E) Unit Accessories: Transformers (except when Electric Heat is selected) All FMA control sequences are available with the reheat type Electric Heat, BUT only the DFMT or factory mounted controls are available with No Heat or Hot Water Heat. PFMT is only available with Electric Heat. All FMA control sequences are piped and wired by T&B. T&B cannot calibrate FMA Controls. Transformers are not supplied as standard on DFMT or factory mounted controls. They must be selected from the Unit Accessories, if required. If Electric Heat is selected, then a transformer matching the electric heater voltage is supplied as a standard. Factory Mounting of controls supplied by others - Please contact a T&B Applications Engineer before ordering. These controls sequences will utilize controls supplied to the T&B manufacturing facility by others. Each of these control sequences needs to be approved by T&B engineering before the order can go into production (please see FMA Section, page SD-23. T&B requires a FMA controls checklist and a legible wiring diagram before the order can be released. Balancing tees are supplied with these control sequences. PFMT - Field mounted Pneumatic Controls supplied by others with Electric Heat. Balancing tees are not supplied with PFMT DFMT - Field mounted FMA Controls supplied by others. Balancing tees are not supplied with DFMT. SD - 13
12 General Notes on How to Specify Notes UNIT ACCESSORIES Chicago Code (A) - Chicago Code option includes a dust tight control enclosure and a dust tight toggle switch. Chicago Code is not a control enclosure, but an add on to an existing control enclosure. Compatible with: Controls: Analog and FMA Controls Controls: Pneumatic Controls Unit Accessories: Dust Tight Sealing (E) Unit Accessories: Controls Disconnect Door Switch (D) Electric Heat Accessories: Door Fused Interlocking Disconnect Switch (K) Electric Heat Accessories: Non-Fused Interlocking Disconnect Switch (L) Electric Heat Accessories: Fusing (C) Controls Disconnect Switch (D) - Controls Disconnect Switch is a toggle disconnect switch. It turns off the power to the control enclosure. Compatible with: Controls: Analog Controls and FMA w/ No Heat & Hot Water Heat Controls: Pneumatic Controls Controls: Any controls w/ Electric Heat Dust Tight Sealing for Control Enclosure (E) - Dust Tight for Control Enclosure is not a control enclosure. It is gasketing and sealing of the control enclosure, when the cover is fastened to the control enclosure, it does not allow dust to enter the control enclosure. Compatible with: Controls: Analog Controls and FMA w/ No Heat, Hot Water Heat & Electric Heat Controls: Pneumatic Controls w/ Electric Heat Pneumatic Controls w/ No Heat or Hot Water Heat Transformer 24V/24V (G) - This 40 VAC transformer takes 24 Volt power and makes it 24 Volts for the controls. Transformer 120V/24V (H) - This 40 VAC transformer takes 120 Volt power and makes it 24 Volts for the controls. Transformer 208V/24V (J) - This 40 VAC transformer takes 208 Volt power and makes it 24 Volts for the controls. Transformer 240V/24V (K) - This 40 VAC transformer takes 240 Volt power and makes it 24 Volts for the controls. Transformer 277V/24V (L) - This 40 VAC transformer takes 277 Volt power and makes it 24 Volts for the controls. Transformers are compatible with Analog and FMA Controls with No Heat, Hot Water Heat. It is not compatible with Pneumatic Controls or any type of controls with Electric Heat. Requires a control enclosure. Hanger Brackets (S) - Metal brackets for mounting the terminal unit in the plenum space using threaded rod. These hanging brackets are mounted at the plant. Hanger brackets are compatible with all options. SD - 14
13 General Notes on How to Specify Notes HEAT (Hot Water) Right Hand, 1 Row (W11) - Right hand one row hot water coil with a Slip and Drive duct connection. Right Hand, 2 Row (W12) - Right hand two row hot water coil with a Slip and Drive duct connection. Right Hand, 3 Row (W13) - Right hand three row hot water coil with a Slip and Drive duct connection. Right Hand, 4 Row (W14) - Right hand four row hot water coil with a Slip and Drive duct connection. Left Hand, 1 Row (W21) - Left hand one row hot water coil with a Slip and Drive duct connection. Left Hand, 2 Row (W22) - Left hand two row hot water coil with a Slip and Drive duct connection. Left Hand, 3 Row (W13) - Left hand three row hot water coil with a Slip and Drive duct connection. Left Hand, 4 Row (W24) - Left hand four row hot water coil with a Slip and Drive duct connection. Heat (Electric) Pneumatic Heater Standard Components - Air flow switch, 80/20 nickel chromium (NiCr) wire, magnetic contactors, high limit (auto reset) switch, manual reset switch, P.E. Switch, and a transformer (50 VAC) that matches the electric heater voltage. Analog/FMA Heater Standard Components - Air flow switch, 80/20 nickel chromium (NiCr) wire, magnetic contactors, high limit (auto reset) switch, manual reset switch, and a transformer (50 VAC) that matches the electric heater voltage. Electric Heater Codes: E Volt, 1 Phase, 1 Step Electric Heater (120/24 transformer) E Volt, 1 Phase, 2 Step Electric Heater (120/24 transformer) E Volt, 1 Phase, 3 Step Electric Heater (120/24 transformer) E Volt, 1 Phase, 1 Step Electric Heater (208/24 transformer) E Volt, 1 Phase, 2 Step Electric Heater (208/24 transformer) E Volt, 1 Phase, 3 Step Electric Heater (208/24 transformer) E Volt, 1 Phase, 1 Step Electric Heater (240/24 transformer) E Volt, 1 Phase, 2 Step Electric Heater (240/24 transformer) E Volt, 1 Phase, 3 Step Electric Heater (240/24 transformer) E Volt, 1 Phase, 1 Step Electric Heater (277/24 transformer) E Volt, 1 Phase, 2 Step Electric Heater (277/24 transformer) E Volt, 1 Phase, 3 Step Electric Heater (277/24 transformer) E Volt, 3 Phase, 1 Step Electric Heater (208/24 transformer) E Volt, 3 Phase, 2 Step Electric Heater (208/24 transformer) E Volt, 3 Phase, 3 Step Electric Heater (208/24 transformer) E Volt, 3 Phase - 4 wire, 1 Step Electric Heater (277/24 transformer) E Volt, 3 Phase - 4 wire, 2 Step Electric Heater (277/24 transformer) E Volt, 3 Phase - 4 wire, 3 Step Electric Heater (277/24 transformer) SCR Heater Codes: C Volt, 1 Phase, SCR Heater (120/24 transformer) C Volt, 1 Phase, SCR Heater (208/24 transformer) C Volt, 1 Phase, SCR Heater (240/24 transformer) C Volt, 1 Phase, SCR Heater (277/24 transformer) C Volt, 3 Phase, SCR Heater (208/24 transformer) C Volt, 3 Phase - 4 wire, SCR Heater (277/24 transformer) SD - 15
14 General Notes on How to Specify Notes KILOWATTS (kw) Kilowatt Range for SDV - Electric Heat: 0.5 to 36.0 (see page SD-9 for individual size kw breakdown) SCR Heat: 0.5 to 24.9 (see page SD-9 for individual size kw breakdown) Kilowatt Range Breakdown for SDV - From 0.5 kw to 10.0 kw, electric heaters are built in 0.5 kw increments. For heaters from 10.0 to 36.0, electric heaters are built in 1.0 kw increments. ELECTRIC HEAT ACCESSORIES Mercury Contactor (B) - Mercury Contactor replaces the standard magnetic contactor. It is compatible with everything. Fusing (C) - Fusing on the high voltage side of the control enclosure acts as a safety in case of a power surge. Electric Heat Accessories: Fused Door Interlocking Disconnect Switch (K) Fused Door Interlocking Disconnect Switch (K) - Fused Door Interlocking Disconnect Switch is a combination of Non-Fused Door Interlocking Disconnect Switch and Fusing. Unit Accessories: Controls Disconnect switch (D) Electric Heat Accessories: Non-Fused Door Interlocking Disconnect Switch (L) Electric Heat Accessories: Fusing (C) Non-Fused Door Interlocking Disconnect Switch (L) - This disconnect switch powers off the electric heat and the controls. SCR HEAT ACCESSORIES Unit Accessories: Controls Disconnect switch (D) Electric Heat Accessories: Fused Door Interlocking Disconnect Switch (K) Fusing (F) - Fusing on the high voltage side of the control enclosure acts as a safety in case of a power surge. Door Interlocking Disconnect Switch (D) - This disconnect switch cuts the power to SCR heat and the controls. Unit Accessories: Controls Disconnect switch (D) Pneumatic Heater (P) - This heater option ships with a transducer that accepts a field piped 3 to 15 psi signal. Unit Accessories: Controls Disconnect switch (D) SD - 16
SINGLE DUCT TERMINAL UNITS
www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product
More informationSDL Single-Duct, Low-Height, VAV Terminals
SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 23 3600 - AIR TERMINAL DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units/devices. 2. Shut off air terminal units/devices. 3. Dual duct terminal units/devices.
More informationTSS Single-Duct VAV Terminals
TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 3 Construction Features... 4 Standard and Optional Features.... 5 Dimensional and Weight Data....
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals Catalog: ET130.13-EG2 (708) TABLE OF CONTENTS Single-Duct, Low-Height VAV Terminals Features and Benefits....................... 2 Controls..................................
More informationVariable Air Volume Dampers
OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationProduct Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.
Product Data 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm 45J,M 45K,N 45Q,R The 45J,M,K,N,Q,R units were designed to maintain accurate temperatures
More informationSINGLE DUCT AIR TERMINAL UNITS
SINGLE DUCT AIR terminal units SINGLE DUCT AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to
More informationDual Duct Variable Air Volume Terminal (Model TDS)
Product Bulletin Issue Date June 21st, 2005 Dual Duct Variable Air Volume Terminal (Model TDS) Model TDS terminals provide Variable Air Volume (VAV) control beyond the typical dual duct box. They are specifically
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationRAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL
RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model
More informationATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.
ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.
More informationDaikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017
Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com
More informationProduct Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals
Product Data 5J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm Series Fan Box 5J,K,Q Parallel Fan Box 5M,N,R 5J,M 5K,N 5Q,R The 5J,M,K,N,Q,R units were
More informationSINGLE DUCT AIR TERMINAL UNITS
AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of
More informationFS Fan-Coil Units Hi-Rise, Vertical
FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04
More informationProduct Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm
Product Data 35E Single Duct Terminal Units for Variable Air Volume Systems Nominal 45 to 7100 cfm Single duct variable air volume (VAV) terminal units provide: 22-gage galvanized steel, unit casing lined
More informationTVS/R FAN COIL UNITS HI-RISE, VERTICAL
TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationVAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE
TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also
More informationIAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW
SINGLE DUCT w/hot WATER HEAT Model AVW Model AVW The Carnes Model AVW is available as a basic control unit with hot water reheat and open end discharge, with an optional sound attenuator module, and optional
More informationIAQ. Model AVC. SINGLE DUCT VAV Model AVC
NON FAN POWERED UNITS SINGLE DUCT VAV Model AVC Model AVC The Carnes Model AVC is available as a basic control unit with open end discharge, with an optional multi-discharge adapter module, or sound attenuator
More informationD2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS
D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable
More informationSingle-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6
Table of Contents Model Number Description SD 2 3 Service Model Number Description SD 4 Selection Procedure SD 5 6 General Data Valve/Controller Airflow Guidelines SD 7 Performance Data Pressure Requirements
More informationProduct Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm
Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA
More informationLMHS BASIC UNIT NO CONTROLS
JOB NAE ARCHITECT ENGINEER CONTRACTOR OCATION SUBITTA SHEET Form Number TS0000.10 Effective Date 6/08 Replaces Form TS0000.9 BASIC UNIT NO CONTROS CHARTED 'A' DIENSION INCUDES INET ADAPTER PROVIDED ON
More informationIAQ. ROUND DUCT RETROFIT Model ARR
Non Fan Powered Units ROUND DUCT RETROFIT Model ARR IAQ External Insulation Standard The Carnes Model ARR offers low pressure drop, low sound levels, and valve characteristics which create stable control
More informationLaboratory Room Single Duct Supply Air Terminal
Technical Specification Sheet Document No. 149-319A June 24th, 2010 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The APOGEE Automation
More informationFAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES
FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing
More informationI Fan Powered Terminal Unit
I Fan Powered Terminal Unit VARIABLE VOLUME PARALLEL FLOW Fan Powered Terminal Unit Variable volume parallel flow Product Overview Variable Volume/Parallel Flow Fan Powered Terminal Units Honeywell parallel
More informationElectric Furnace KF/KFS Series
Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20-208V 24-240V 48-480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Direct drive motor Up to 3-speed motor Standard 24 Volt
More informationVariable Air Volume (VAV) Pressure Independent Control
VAV Terminal Units Asli Variable Air Volume (Vav) Terminal Units are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of conditioned
More informationSubmittal. Front View Side View
RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.
More informationAIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit
IOM 002 Effective 4/06 AIR FLOW SOLUTIONS Installation, Operation, & Maintenance MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit
More informationLaboratory Room Single Duct Supply Air Terminal
Technical Specification Sheet Document No. 149-319P25 July 28, 2017 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The Laboratory Room
More information500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)
500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5
More informationUniversity of Delaware
SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section
More informationVERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.
More informationHorizontal and Vertical BELT DRIVE AIR HANDLING UNITS
Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS TABLE OF CONTENTS H & V Features and Benefits...4 Coil and Filter Data, Static Pressure Data...7 Electric Resistance Heat Section...8 Coil Information
More informationSubmittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]
BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing
More informationApplication Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification
Date: October 22, 1999 Rev: 00 Doc. No. AG-LHK-01 Application Guide This Application Guide has been developed to introduce the LHK access floor fan powered terminal. In this Guide you will find a description
More informationVAV Terminal Unit Control Package
VAV Terminal Unit Control Package Model CP-133-STK Pneumatic Pressure Independent, VAV Cooling, Constant Volume Heating at Min CFM set point. This actuator/controller will accommodate Direct or Reverse
More informationcatalog SDR Single-Duct VAV Terminals
catalog SDR Single-Duct VAV Terminals TABLE OF CONTENTS Features And Benefits...2 Standard Construction...6 Optional Construction...7 Standard And Optional Features...8 Application And Selection...9 Airflow
More informationFDU HOT WATER COILS COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DOWNSTREAM HEATING COIL OUT
COIL DISCARGE COLLAR FDU OT WATER COILS OPT. CAD SECTION COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DISCARGE COLLAR COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) 3.500 (89) 6.500 (165) (SZ 10-40)
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-23 36 00.00 40 (May 2016) ----------------------------------- Preparing Activity: NASA Superseding UFGS-23 36 00.00 40 (February 2011) UFGS-23 36 00 (November 2010) UNIFIED
More informationSubmittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]
FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More informationFan Powered Low Profile Variable Volume Terminal Units
MANUAL INSTALLATION Fan Powered Low Profile Variable Volume Terminal Units FEVLP / FPVLP / FDVLP Series v001 Issue Date: 07/19/16 07/19/16 Price Industries Limited. All rights reserved. TABLE OF CONTENTS
More informationCatalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI
Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal
More informationRETROFIT TERMINAL UNITS
GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable
More informationTechnical information
6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes
More informationWAC Air Curtains Technical Guide
TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2
More informationPH SERIES SINGLE DUCT ATU PERFORMANCE DATA
PH SERIES SINGLE DUCT ATU PERFORMAE DATA The Performance Aire PH Series is the simplest and most widely used VAV terminal unit. Its basic components are an insulated sheet metal box, round inlet damper,
More informationIOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T
IOM 002 Effective 12/17 A I R D I S T R I B U T I O N A I R F L O W S O L U T I O N S I n s t a l l a t i o n, O p e r a t i o n, & M a i n t e n a n c e M O D E L Q S T Q u i e t, S e r i e s ( C o n
More informationATU PRODUCT CATALOG AIR TERMINAL UNITS OPTIONS AND ACCESSORIES Metal Industries, Inc.
ATU PRODUCT CATALOG AIR TERMINAL UNITS OPTIONS AND ACCESSORIES AND REFERENCE INDEX OF SECTIONS Options Overview 2 Hanger Bracket and Inlet Attenuator 4 Insulation Descriptions 5 Access Panels 6 Inlet Flow
More informationC2-2. Table of Contents DUAL DUCT TERMINAL UNITS
C2 UA UCT TERINA UNITS Table of Contents UA UCT TERINA UNITS This unit features a compact design for variable volume applications where blending of hot and cold air is not required. T This unit features
More information500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)
500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage
More informationSBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL
SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES
More informationINSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.
INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is
More informationVAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD
VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL
More informationHORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change
More informationRBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL
RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated
More informationAIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT
ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN
More informationcatalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals
catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 4 Construction Features... 5 Standard and Optional Features.... 7 Application and
More informationengineering guide TCS Series Fan-Powered, VAV Terminals
engineering guide TCS Series Fan-Powered, VAV Terminals FORM 130.13-EG4 (908) TABLE OF CONTENTS Series Fan-Powered, VAV Terminals Features and Benefits....................... 2 Construction Features.......................
More informationElectric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System
V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses
More informationcatalog CFR Series Fan-Powered, VAV Terminals
catalog CFR Series Fan-Powered, VAV Terminals TABLE OF CONTENTS Features and Benefits...2 Construction Features...4 Standard And Optional Features...6 Application Selection...7 Application and Selection....8
More informationSINGLE DUCT TERMINAL UNITS 30X/HQX SERIES
30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an
More informationSPVQ / SDVQ Series QUIET SINGLE DUCT TERMINAL UNIT
Patented SPVQ / SDVQ Series QUIET SINGLE DUCT TERMINAL UNIT In an era of increasing IAQ and noise concerns, this innovative product is specifically designed to meet the challenges headon. Certified assemblies
More informationFan-Powered Series. Table of Contents. Model Number Description FPS 2 3. Service Model Number Description FPS 4. Selection Procedure FPS 5 7
Table of Contents Model Number Description FPS 2 3 Service Model Number Description FPS 4 Selection Procedure FPS 5 7 General Data Valve/Controller Airflow Guidelines FPS 8 Performance Data Pressure Requirements
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationProduct Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems
Product Data AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems 45UC 35BF-R 42KC 45XC 35BF-D Features/Benefits Access Floor Systems can provide flexibility and economic
More informationcatalog VFL Parallel Fan-Powered, Low-Height, VAV Terminals
catalog VFL Parallel FanPowered, LowHeight, VAV Terminals TABLE OF CONTENTS Features And Benefits...2 Construction Features...4 Standard And Optional Features...6 Application And Selection...7 Application
More informationSPV / SDV Series SINGLE DUCT TERMINAL UNITS
SPV / SDV Series SINGLE DUCT Price single duct terminal units are designed to control the airflow rate of conditioned air into an occupied space with minimal pressure drop and low noise levels. An extensive
More informationcatalog CFRQ, Extra Quiet Series Flow, Constant Volume Fan Powered VAV Terminals
catalog CFRQ, Extra Quiet Series Flow, Constant Volume Fan Powered VAV Terminals TABLE OF CONTENTS Features And Benefits... 2 Construction Features... 4 Standard & Optional Features... 6 Application And
More informationFan-Powered Parallel
Table of Contents Model Number Description 76 Selection Procedure 77-79 General Data Setting Guidelines 80 Performance Data Pressure Requirements 81 Performance Data Fan Curves 82-85 Performance Data Hot
More informationDirect Gas-Fired Heating
Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is
More informationcatalog VFR Parallel Flow, Fan-Powered, VAV Terminals
catalog VFR Parallel Flow, FanPowered, VAV Terminals TABLE OF CONTENTS Features and Benefits... 2 Controls... 4 Construction Features... 5 Standard and Optional Features... 7 Application and Selection....
More information500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)
500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor
More informationRAH Engineering Guide
FAN COIL UNITS FREE RETURN RAH Engineering Guide SO TOUGH, WE GUARANTEE IT. RAHC RAHO RAHR www.superiorrex.com Table of Contents Features and Benefits... 3 Construction Features... 4 Standard and Optional
More informationDaikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019
Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationElectronic Controls. Electronic Controls Sections
Electronic Controls Electronic Controls Sections Controllers, Thermostats, and Switches Enclosures Relays Sensors, Transmitters, and Transducers Power Supplies and Transformers See the Contents Section
More informationFN Fan-Coil Units High-Performance, Horizontal
FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See
More informationFan-Powered Parallel
Table of Contents Service Model Number Description FPP 2 Selection Procedure FPP 3 5 General Data Valve/Controller Guidelines FPP 6 Performance Data ir Pressure Requirements FPP 7 8 Performance Data Fan
More informationFan - Powered Terminal Unit Series Flow
5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone
More informationLIST PRICES WAC AIR CURTAINS
PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM
More informationNV series. Induction VAV air volume control terminals
NV series Induction VAV Description Table of contents Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NVOAOOB...
More informationHORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED
Direct Drive, Draw-through Design Model Series 3FH Filter 1" (2) throwaway (standard) 2" (1) MERV 8 or MERV 13 pleated (optional) Multiple coil options: 3, 4,, 6 row cooling or heating coils 1 or 2 row
More informationcatalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals
catalog VFR Parallel Flow, FanPowered, 50/60 Hz VAV Terminals TABLE OF CONTENTS Features and Benefits...2 Controls...4 Construction Features...5 Standard and Optional Features...7 Application and Selection....8
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationGeneral Information... 2
VAV Flow Controller-Actuators CSP 5001/5002 Applications Guide General Information... 2 CSP 5001/5002 Overview...2 Controller, Sensor, and Thermostat Functions...3 Wiring...4 Air Flow Sensor Connection...4
More informationUNDERFLOOR FAN POWERED TERMINAL UNITS
UNERFLOOR FAN POWERE TERMINAL UNITS 1 UNERFLOOR FAN POWERE TERMINAL UNITS Contents UNERFLOOR FAN POWERE TERMINAL UNITS Underfloor Fan Powered Terminal Units Model 38S, 38SE, 38SW Features, Options, Accessories
More informationProduct Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm
Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional
More informationMODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS
MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS INSTALLATION OPERATION & MAINTENANCE New Release Form 130.13-NOM4 (908) In conjunction with the use of these instructions, obtain and refer to the construction,
More information