1 VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines Installation and Users Manual For the following Prelube Kits: VARNA Products P/N 6423 Kit for 208 VAC 3 Phase VARNA Products P/N 6863 Kit for 240 VAC 3 Phase VARNA Products P/N 6521 Kit for 480 VAC 3 Phase This manual describes the installation and use of the 15 GPM (57 LPM) VARNA Products Prelube Kits for MTU 4000 Series Engines. This kit contains most of the components required for installation on these engines. Manufactured by VARNA Products division, Transportation Research Corp Business Drive, Cameron Park, CA 95682, USA

2 This page intentionally left blank. 10/27/10 Page 2 of 16

3 Table of Contents Product Description... 4 SAFETY INFORMATION... 5 Prelube Kit Description... 6 Hose Selection... 7 Prelube Pump Installation... 7 Prelube Oil Pressure Switch Installation... 8 Prelube Control Unit Installation... 9 Manual Prelube Operation Semi or fully-automatic operation TROUBLE SHOOTING Table of Figures Figure 1: Wiring the Control Unit Figure 2: Control Box Dimensions Figure 3: Pump Mounting Dimensions Figure 4: Schematic for the VARNA Products Prelube Control Unit Figure 5: Schematic for Remote Push Button Station(s) /27/10 Page 3 of 16

4 Product Description VARNA Products P/N 6523 Prelube Kit The VARNA Products P/N 6523 Prelube Kit includes a 15 gpm (57 LPM) VARNA prelube pump, the VARNA prelube pump Control Unit, a low voltage control wiring set, the engine prelube oil pressure switch and related plumbing, and certain plumbing hardware necessary to install the prelube system on an MTU 4000 series engine. Prelube Kits are available for various voltages. An external check valve is not required and is not recommended for this prelube pump installation. The VARNA CF-15 Prelube pump contains its own integral freeflow check valve. This valve prevents the engine oil pump from forcing oil backwards through the prelube pump when the engine is running. The VARNA CF-15 Prelube pump contains its own integral 50 psi (3.5 bar) pressure relief valve. This valve prevents pump motor overload when the engine starts and the oil pressure from the engine exceeds 50 psi (3.5 bar). Certain installation related components need to be supplied by the installer. These include the power wiring to the Control Unit and the power wiring between the Control Unit and the pump, the oil hoses between the pump and the engine, and any desired remote operator stations. The VARNA Prelube Control Unit provides all the functions for the operation of the VARNA CF15 engine prelube pump. The prelube operation can either be manually controlled by local or remote pushbuttons, or it may be connected to various engine control devices for semi-automatic or fully-automatic prelube control. Control unit installation is quick and easy with all of the external electrical connections on a common rail for easy accessibility. The Control Unit itself has a manual prelube button that, when pushed, operates the prelube pump and illuminates when the preset oil pressure is reached at the prelube oil pressure switch. External connections are provided that allow one or more remote prelube operator stations to be connected to the Prelube Control Unit. The Prelube Control Unit is self contained with a power disconnect switch, a contactor for prelube pump motor operation, and a prelube pump motor protection circuit to protect against phase failure, motor overload, and short circuits. This kit also includes a two conductor cable for connecting to the included engine oil prelube pressure switch, and a four conductor cable for connecting any desired external prelube control signals or pushbutton stations (not-included). Low voltage control circuit components are protected by circuit breakers located within the prelube control cabinet. No spare fuses are required nor needed. 10/27/10 Page 4 of 16

5 SAFETY INFORMATION High voltages in and around this equipment can cause serious or fatal injury. Installation, maintenance, or repair should be done by qualified personnel. Improper use of this equipment can cause serious or fatal injury. WARNINGS and CAUTIONS WARNING The prelube pump output pressure hose to the engine is pressurized by the engine oil pump at all times while the engine is running. A hose capable of containing 150 psi (10 bar) engine lubrication oil at 275 F (135 C) must be used. Failure of this hose can drain the engine of oil and cause serious or fatal burns. WARNING This equipment operates on 460 VAC. Only qualified personnel should install or maintain this equipment. Before working on this equipment make sure that ALL power to this equipment has been disconnected and that no other sources of power exist that may create an electrical shock hazard within this equipment. Electric shock can cause serious or fatal injury. WARNING This equipment uses both high voltage power and low voltage control. Note that the high and low voltage systems are isolated from each other. Crossing or other misuse of these systems can create serious electrical shock hazards in remote locations outside of this equipment. Electric shock can cause serious or fatal injury. WARNING This equipment can be accidentally or purposely remotely operated at any time. Always insure that all means of energizing this equipment have been locked out or otherwise disabled during installation and maintenance of the prelube pump. Unexpected prelube pump operation during installation and maintenance can cause electrical shock hazards or entanglement in moving or rotating parts resulting in serious or fatal injuries. CAUTION The prelube pump can be accidentally or purposely remotely operated at any time. Make sure that all means of energizing the prelube pump are locked out or otherwise disabled before changing oil filters, disconnecting the associated oil lines, or maintaining any other equipment that may cause oil spillage by unintended prelube pump operation. CAUTION Maximum vibration in the 10 to 55 Hz. range is 1 g RMS. Excessive vibration can damage the control box. The control box must be mounted in locations that do not receive direct vibration from the engine or other sources. CAUTION It is always good practice to completely install the prelube pump and hoses to the engine prior to connecting power to the motor. CAUTION The source panel must provide suitable circuit protection to protect the cable between the source panel and the Prelube Control Unit. 10/27/10 Page 5 of 16

6 Prelube Kit Description The Varna Products 6523 Prelube Kit includes two major components. The first is the VARNA Products CF-15 engine pre-lube/post-lube pump with internal check and pressure relief valves. The second is the Prelube Pump Control Unit complete with a power disconnect switch, prelube pump motor protection, and a manual prelube button. This kit also includes the necessary support components such as cord grips for the electric cables, the small electric cables for connecting the pressure switch and remote control station, and various plumbing fittings for connecting the prelube pump to the engine. The following is a complete list of the components contained in this kit: P/N NAME/DESCRIPTION 6085 CF-15 prelube pump for /460 V 3Ø AC operation VAC Prelube control Unit Prelube Oil Pressure Switch Cable, 30 Feet (9.1 Meters) Remote Control Cable, 20 Feet (6.1 Meters) Prelube Oil Pressure Switch Pressure Switch Connection Tee ¼ inch straight thread pump fitting (Parker 20FOX) inch straight thread pump fitting (Parker 16FOX) ¼ inch NPT engine fitting (Parker 20-16FTX) inch NPT engine fitting (Parker 16FTX) 6407 MTU 4000 series Engine Pressure Port Fitting each M10-1.5x40 class 8.8 Cap Screw P/N P/N P/N 6085 P/N 6423 for 208VAC 3 Phase P/N 6863 for 240VAC 3 Phase P/N 6521 for 480VAC 3 Phase P/N 6433 P/N 6443 P/N 6287 P/N 4814 P/N 6444 P/N 6445 P/N x P/N /27/10 Page 6 of 16

7 Hose Selection The engine oil can reach temperatures of 275 F (135 C). Both the pressure and suction hoses for the prelube pump must be rated for engine lubrication oil at a minimum of this temperature. The pressure hose must also be rated for 150 psi (10 bar) working pressure or better. Prelube Pump Installation 1. Location of the CF-15 prelube pump a. The best elevation for installing the CF-15 prelube pump is at or just above the normal engine oil level. Installation drawings are shown in Figure 3. b. The motor should be horizontal. The base can be down, up or at any angle. The pump can be repositioned on the motor to any of four positions. c. Locate a suitable port in the engine oil pan for connecting the prelube pump suction hose. Also locate a suitable engine oil pump outlet port for the prelube pump pressure hose connection. Be aware that similar ports may serve different functions. Consult the engine documents to determine the proper port. d. The prelube pump location should minimize the length of the pump inlet hose. The shorter the pump inlet hose the better the pump performance in cold weather. Call VARNA Products engineering department at Pacific Time for information on suction lines longer than 4 feet. e. Other locations for the prelube pump are workable but may compromise the pump performance somewhat. If there is any question, please contact VARNA Products engineering department at Fabricating the suction hose from the engine pan to the pump. a. Engine oil can reach temperatures of 275 F (135 C). The suction must be rated for engine oil at this temperature. b. The suction hose length and diameter are important to pump performance. A suction hose longer than 4 feet (1.2 Meters) will reduce the performance of the pump increasing the time for prelubing the engine. A suction hose diameter smaller than 1 1/4 inches will severely reduce prelube pump performance. Call VARNA Products engineering department at Pacific Time for specific installation information about your installation. c. Make up a 1-1/4 inch diameter hose that extends from the engine oil pan port to the pump inlet port with female JIC fittings on both ends. 3. Fabricating the pressure hose from the pump to the engine. a. WARNING THE OUTPUT PRESSURE HOSE FROM THE PUMP TO THE ENGINE IS PRESSURIZED BY THE ENGINE OIL PUMP AT ALL TIMES WHILE THE ENGINE IS RUNNING. A HOSE OF ADEQUATE DESIGN CAPABLE OF CONTAINING 150 PSI ENGINE OIL AT 275 F (135 C) MUST BE USED IN THIS LOCATION. FAILURE OF THE PRESSURE HOSE CAN DRAIN THE ENGINE OF OIL AND CAUSE SERIOUS OR FATAL BURNS FROM SPRAYING HOT OIL. 10/27/10 Page 7 of 16

8 b. Using the proper quality hose material, make up a 1-inch diameter hose from the pump pressure port to the engine pressure port with female JIC fittings on both ends. While this pressure hose is less sensitive to length than the suction hose, it is always good practice to create a clean installation with no extra length of hose to get into the way. 4. Connecting the prelube pump and hoses to the engine. a. While it is possible with some oil spillage for the creative mechanic to install these fittings and hoses without first draining the oil, it is highly recommended that the engine be drained of oil prior to this operation. b. Mount the pump in its intended location. c. Install P/N 6287 and P/N 6288 connector fittings into the prelube pump. d. Replace the engine oil pump outlet port cover with the VARNA P/N 6407 adapter using the three P/N 6509 bolts supplied. Be aware that similar ports may serve different functions. Consult the engine documents to determine the proper port. e. Install the P/N 6445 adapter into the P/N 6407 adapter plate. f. Install the P/N 6444 adapter into the engine oil pan. g. Connect the suction hose from the oil pan fitting to the pump inlet port. h. Connect the pressure hose to the pump outlet port fitting. i. Fill the pressure line with clean engine oil. This makes sure that the pump has some oil to lubricate its parts and reduces the amount of air pumped into the engine during initial startup. j. Connect the other end of the pressure line to the pressure port fitting on the engine. Prelube Oil Pressure Switch Installation 1. The prelube oil pressure switch is installed at the same location as the engine oil pressure switch. 2. Disconnect and remove the existing engine oil pressure switch. It will be reinstalled later on the running port of the tee. 3. Install the VARNA P/N 6443 pressure switch connection tee in the pressure switch port. 4. Install the VARNA P/N 6433 prelube pressure switch into the side port of the pressure switch connection tee. 5. Install the Tee in to the engine oil pressure port. 6. Reinstall the engine oil pressure switch into the end port of the tee. 7. Reconnect the engine oil pressure switch electrical connection. 8. See Installation of The Prelube Control Unit on page 9 for instructions on connecting the prelube pressure switch wire. 10/27/10 Page 8 of 16

9 Prelube Control Unit Installation 1. Locate the Prelube Control Unit in an appropriate location for electrical equipment associated with the engine. There are cable grips installed for the power cable from the power source to the Control Unit and for the motor cable from the Control Unit to the Prelube Pump Motor. For mounting dimensions, see Figure Install the two 4-conductor power cables (user supplied) to and from the Prelube Control Unit. a. The minimum conductor size for these power cables is 16 AWG (1.5mm 2 ). Note that larger conductor sizes may be dictated by the length of the run, by the circuit protection device in the source power panel, by specific codes, or by standard practice. b. Connect the first 4 conductor power cable from the 460 VAC 3 phase source panel to the blue L1, L2, L3, & Ground terminals inside the Prelube Control Unit. c. Connect the second 4 conductor power cable from the gray T1, T2, T3, & Ground terminals inside the Prelube Control Unit to the appropriate Prelube Pump motor terminals for 460 Volt operation. 3. Install the prelube oil pressure switch cable from the Control Unit to the prelube oil pressure switch at the engine. a. This is the 30 foot (9.1m) long 2-conductor VARNA P/N cable supplied with this kit. Install the end the cable with the sheath cut back about 5 inches into the right front cord grip and connect the wires to the two orange connectors as shown in the Figure 1 on page 9. b. This cable is routed from the Control Unit to the Prelube Oil Pressure switch previously installed on the engine. The black wire is connected to one of the terminals on the Prelube Oil Pressure Switch and the white wire is connected to the other terminal. 4. Remote prelube station(s). a. If a remote control device is not used, remove the front left cord grip and close the hole with a suitable plug. b. A 20-foot (6.1m) long 4-conductor P/N cable is supplied in this kit. Install the end with the cable sheath cut back about 5 inches (125mm) into the right front cord grip and connect the red, green, black, and white wires to the red, green, black and white set of connectors also shown in Figure 1. c. Rout this cable to the location of the remote prelube station. If necessary, this cable can be extended by attaching an additional length of AWG-16 (1.5mm 2 ) wire. Note: The maximum length of AWG-16 (1.5mm 2 ) cable from the Control Unit to furthest remote switch is 44 feet (13.4m). Longer cables may result in insufficient current to operate the contactor in the Prelube Control Unit. d. At the remote location, use a switch or relay to contact the white wire in the Control Cable to the Black wire in the same cable. While the switch or relay 10/27/10 Page 9 of 16

10 is closed, the Prelube Pump will run. NOTE: The current draw through the switch or relay will be about 400 ma steady with a 4 Amp inrush. The voltage across the open switch or relay contacts will be approximately 24 VAC. e. Optional: Connect the green and Red wires in the Control Cable to a 24 Volt rated pilot lamp. When the prelube pump is running, the prelube button lamp will indicate that the preset oil pressure has reached at the prelube pressure switch. This signal may also be used to energize a 24 VAC relay to signal an automated engine control that the preset engine prelube oil pressure has been reached. 5. Verify that the Prelube Pump is installed and plumbed according to its installation instructions. 6. Turn on the power source to the Prelube Control Unit. 7. Turn the Manual Disconnect on the Prelube Control Unit to the ON position. 8. Verify the pump rotation by quickly tapping the RUN PRELUBE button on the Control Unit and visually checking the rotation of the fan in the motor. The pump motor must rotate counterclockwise when viewed from the fan end. 9. Verify that there is oil in the engine sump. 10. Push and hold the RUN PRELUBE button on the Control Unit. The prelube pump will run until the button is released. The lamp will illuminate when the preset engine prelube oil pressure has been reached at the prelube pressure switch. The Remote Prelube Operator station wires connect to the BLACK, WHITE, RED, and GREEN terminals here. The Power wires from the Source Panel connect to the BLUE terminals here. The Prelube Oil Pressure Switch wires connect to the ORANGE terminals here. The Power wires to the Prelube Pump motor connect to the GRAY terminals here. Figure 1: Wiring the Control Unit 10/27/10 Page 10 of 16

11 Manual Prelube Operation 1. The engine prelube pump can be operated by pushing the prelube button on the control box. Additionally, the prelube pump can be operated at any of the optional remote prelube operator stations. 2. The Prelube pump will run while the button is pushed or the black and white wires in the control cable are connected by a switch or relay. 3. When the preset prelube oil pressure is detected at the engine prelube pressure switch, the button lamp will light. Note: The lamp is optional in remote prelube operator stations. Semi or fully-automatic operation The VARNA Products Prelube Control Unit has three external control signals that can be used to operate the prelube pump and report the state of the engine prelube pressure switch. 1. The first signal is the Pressure Switch Signal. It is an input signal to the Prelube Control Unit from the engine Prelube Pressure Switch. A contact closure between the two orange connector blocks in the Prelube Control Unit while the prelube pump is operating will illuminate the button lamp in the control unit and any connected remote lamps. Relays may be connected to the lamp circuit to signal external equipment of this event. 2. The second signal is the Operate Pump Signal. It is an input signal to the Prelube Control Unit from a remote switch or a relay contact closure that is used to run the prelube pump. A contact closure between the White and Black connector blocks in the Prelube Control Unit will cause the prelube pump to run. The prelube pump will continue to run until the contact closure opens. 3. The third signal is the Prelube Complete signal. It is a 24-VAC output signal from the Prelube Control Unit used to illuminate any connected button lamps, other lamps and/or relays. It is on the Red and Green connector blocks in the Prelube Control Unit. This signal is derived from the Pressure Switch signal. 10/27/10 Page 11 of 16

12 Figure 2: Control Box Dimensions 10/27/10 Page 12 of 16

13 Figure 3: Pump Mounting Dimensions 10/27/10 Page 13 of 16

14 Figure 4: Schematic for the VARNA Products Prelube Control Unit Figure 5: Schematic for Remote Push Button Station(s) 10/27/10 Page 14 of 16

15 TROUBLE SHOOTING 1. The button does not illuminate and the Prelube Pump does not run: a. Check that the circuit breaker to the Prelube Pump Control Unit is on. It might be tripped or turned off. b. Check that the disconnect switch on the Prelube Control Unit is on. It might be tripped or turned off. i. If the disconnect trips immediately upon pushing the prelube button, verify that each of the 3 phase power lines into to the Prelube Control Unit has power. Also check for broken or shorted wires leading to the prelube pump motor. ii. If the disconnect switch trips after 3 or more seconds, check for a jammed pump or failed motor. c. Check that the low voltage component protection circuit breakers are on. They are located inside the Prelube Control Unit on the right side. To reset the duel circuit breaker force the blue lever down into the off position and then back to the on position. The button circuit breaker will pop out when tripped. To reset it, push the button back in. A miswired Remote Control station or shorted remote station wires will cause one or both of these circuit breakers to trip. 2. The pump runs but the button lamp does not illuminate to indicate prelube pressure at the engine. a. Verify that there is adequate oil in the engine. Note: Changed oil filters or other maintenance may require a longer prelube time to purge the filters and oil lines. b. Check if maintenance has been performed that would allow air in the oil lines to the pump. While the pump will self prime, it may take some time. c. Check if the engine is hot and therefore the oil is thin. Oil may be present in the engine but thin oil could be flowing through the bearings and other oil paths faster than the prelube pump can supply it. Oil is flowing through the engine but it does not produce enough pressure to operate the prelube pressure switch. d. Check for a failed button lamp. e. Check for breaks or disconnects in the wires to the prelube oil pressure switch. f. Check for leaks in the Prelube Pump suction line and fittings. These leaks are hard to find. A relatively small suction leak can keep the pump from priming. g. Check for proper prelube pressure switch setting. h. Check that the prelube oil pressure switch is functioning properly. 3. The button light turns on immediately when the button is pushed (no delay while the engine is filling with oil). a. Check if the engine is running and therefore oil pressure is already present. b. Check for shorts in the wiring to the prelube oil pressure switch. c. Check that the prelube oil pressure switch is functioning properly. d. Check for proper prelube pressure switch setting. 4. The prelube pump runs whenever power is applied to the control unit. a. Check for shorted wire(s) to the remote prelube station. b. Check for shorted or miswired remote prelube cable at the Control Unit or at the remote prelube station. 10/27/10 Page 15 of 16

16 VARNA Products Phone #: Business Drive Cameron Park, CA USA Industrial Oil & Fuel Pumps & Control Kits for: Prelube Transfer Drain/Fill 10/27/10 Page 16 of 16

PBA Series Prelube Controls

PBA Series Prelube Controls VARNA Products Engineered Innovation PBA Series Prelube Controls Simple, Compact, Industrial Full featured control for running prelube from the control or from a remote station Easy internal wiring connections

More information

Trouble Shooting Guide EWA, 3-phase (D2422)

Trouble Shooting Guide EWA, 3-phase (D2422) Trouble Shooting Guide EWA, 3-phase (D2422) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Breaker tripped, no power to unit Loose wire Defective contactor or coil Close

More information

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM MODEL NUMBER: 10003 MEDIUM DUTY ONBOARD AIR SYSTEM IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using

More information

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide

More information

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO20-115 PRO20-115RD 115-Volt AC PRO20-115AD Automatic Diesel Nozzle PRO20-115MD Manual Diesel Nozzle PRO20-115PO Pump Only PRO20-115RD For Remote Dispensing Systems

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

DC400 Dispensing Cutoff System

DC400 Dispensing Cutoff System DC400 Dispensing Cutoff System Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Important

More information

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

BATTERY SAVER LOW RIPPLE HO

BATTERY SAVER LOW RIPPLE HO INSTRUCTION MANUAL BATTERY SAVER LOW RIPPLE HO LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS MODEL #: 091-195-12 INPUT: 120 Volt, 50/60 Hz, 4.5 Amps RMS OUTPUT: 13.2 Volts DC,

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

Mizer Single Pump and Starter Box

Mizer Single Pump and Starter Box Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...

More information

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

4 ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause 4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

Centrifugal Constant Pressure Control

Centrifugal Constant Pressure Control Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System Installation Instructions DuraMAC TM Light Commercial & Irrigation Water Pressure Booster System The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

Medium and high pressure pumps

Medium and high pressure pumps Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET R 50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET Transfer Relay Delay 00-00803-400 Dual Input Genset INDUSTRIAL CONTROL EQUIPMENT TYPE 1 Shore Power Rating: 120/240VAC 60HZ 1 Phase 50A/Pole Generator

More information

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

HEAVY DUTY ONBOARD AIR SYSTEM PART NO IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL FOR FUTURE REFERENCE

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

Optima ETF-600/ETF-610

Optima ETF-600/ETF-610 Optima ETF-600/ETF-610 4B ETF-610 1C 4A 5 6 7 7 6 ETF-600 1A 1C PARTS LIST ETF-600 AND ETF-610 FAUCETS Item No. Code No. Part No. Description 1A. 065086 ETF-54-A Faucet and Sensor Assembly (ETF-600). 065117

More information

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz. 103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com

More information

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION

More information

MODEL SCA Installation and Operation Manual Important:

MODEL SCA Installation and Operation Manual Important: MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible

More information

rev0 INSTALLATION & OPERATION MANUAL DUAL FLUID CIRCULATING HEATING SYSTEM MODEL DLV

rev0 INSTALLATION & OPERATION MANUAL DUAL FLUID CIRCULATING HEATING SYSTEM MODEL DLV 216306-000 rev0 INSTALLATION & OPERATION MANUAL DUAL FLUID CIRCULATING HEATING SYSTEM MODEL DLV IDENTIFYING YOUR SYSTEM IOM216306-000 The HOTSTART heating system is designed to heat fluids for use in

More information

OutdoorXUPS-600AHV-8364

OutdoorXUPS-600AHV-8364 OutdoorXUPS-600AHV-8364 TSi Power s OutdoorXUPS-600AHV-8364 provides secure and uninterrupted 230 vac power to critical loads. 1) Weather-tight metal cabinet (IP44 or NEMA 3R rated) 2) 2A and 2B are wide

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual Easy Start 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526. www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11 Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

DT34 and DT54 Series Rotary Sprinklers

DT34 and DT54 Series Rotary Sprinklers DT34 and DT54 Series Rotary Sprinklers Installation & Service Instructions Introduction The DT34 and DT54 series full-circle rotary sprinklers are designed specifically for golf course applications. Manufactured

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074

More information

rev0 INSTALLATION & OPERATION MANUAL DUAL FLUID CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OCSE

rev0 INSTALLATION & OPERATION MANUAL DUAL FLUID CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OCSE 216329-000 rev0 INSTALLATION & OPERATION MANUAL DUAL FLUID CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OCSE IDENTIFYING YOUR SYSTEM IOM216329-000 The HOTSTART heating system is designed to

More information

Designed to quickly and safely test fire hose lines!!

Designed to quickly and safely test fire hose lines!! Designed to quickly and safely test fire hose lines!! 3 gpm / 500 psi One - 2-1/2 NST Swivel female quick fill inlet Four - 2-1/2 NST male outlets with individual ball valves 115V, single-phase Meets testing

More information

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 TABLE OF CONTENTS PART I GENERAL DESCRIPTION... PAGE 2 PART II FUNCTIONS... PAGE 2 PART III INSTALLATION... PAGE 3 PART IV INITIAL INSTALLATION

More information

Centrifugal Constant Pressure Control

Centrifugal Constant Pressure Control Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

CALTRAP INSTALLATION AND OPERATIONS MANUAL

CALTRAP INSTALLATION AND OPERATIONS MANUAL INSTALLATION AND OPERATIONS MANUAL NOTE Please read this entire installation and operations manual before energizing the. Safety Considerations: Installing and servicing capacitor equipment can be hazardous.

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Low Profile J Series Power Unit with Vane Pump

Low Profile J Series Power Unit with Vane Pump Low Profile J Series Power Unit with Vane Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING

More information

Instruction & Owner s Manual

Instruction & Owner s Manual Instruction & Owner s Manual Table of Contents Page Installation - Plumbing of Chamber 3 Installation - Electronic Control Box 3-4 Transformer Connection 115VDC or 230VDC 4-5 Instructions for use with

More information

Shock/Vibration Control Switches

Shock/Vibration Control Switches Shock/Vibration Control Switches Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 ` Installation Instructions 00-02-0185 2013-02-01 Section 20 Please read the following information before installing.

More information

BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS

BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS FILE: IM_091-195-12-USB_revB1 REVISED BY: PSS DATE: 06-28-2013 INSTRUCTION MANUAL BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS MODEL #091-195-12-USB

More information

Service Handbook HD /97

Service Handbook HD /97 Service Handbook HD 1050 5.905-032 07/97 Foreword HD 1050 Foreword Indispensable prerequisites for the competent execution of service procedures are comprehensive, real-life training workshops for technical

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL SDKIT-730 & SDKIT-734 100% Bolt-On 150 PSI Train Horn System for 2011-2015 F-250 & F-350 Super Duty P/N SDKIT-730 P/N SDKIT-734 Thank you for purchasing a Kleinn Air Horns

More information

MODEL MC1500 Installation and Operation Manual Important:

MODEL MC1500 Installation and Operation Manual Important: MODEL MC1500 Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible

More information

60 Series Engine Controls

60 Series Engine Controls ECU 60 Series Engine Controls Use CAUTION since you are applying 120VAC RMS to the AC Input terminals and that it is always potentially their during engine run!!! ECU is a registered trademark of Engineering

More information

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232

More information

Lube Level Maintainer

Lube Level Maintainer Lube Level Maintainer Model LM500-TF-ATEX Installation Instructions 00-02-0745 2013-09-16 Section 15 Ex ic IIC T5 Gc X -20 o C < Ta < 85 o C NOTE: To use in an ATEX environment the metal vent cap must

More information

ADVANCED PID TROUBLESHOOTING

ADVANCED PID TROUBLESHOOTING ADVANCED PID TROUBLESHOOTING August 29, 2016 A KEY POINT If the drive is telling you something via a Fault, then the problem is probably not the drive. The drive is recognizing a fault and telling you

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

E.S.P. Embedded Sensing Probes for Motor Brushes

E.S.P. Embedded Sensing Probes for Motor Brushes E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com

More information

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R THE RELIANCE Fast/Tran IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by a qualified electrician thoroughly familiar with all

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions O N DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions Note: For preliminary use only. Introduction The DT35 and DT55 series full-circle/adjustable part-circle rotary sprinklers

More information

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords. Optima ETF-500 ETF-500 TO MOUNT FAUCET ON A SURFACE BETWEEN 0.1 (10 MM) AND 1.00 (25 MM) THICK, USE THE HARDWARE SHOWN BELOW. 7 1B 3B 1A 2 3A 5 6 11 10 5 9 PARTS LIST ETF-500 FAUCET Item No. Code No. Part

More information

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual Model AM2 M40 Panel Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to the

More information

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017 R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating

More information

FlowMax Lift Pump Kit

FlowMax Lift Pump Kit 15 June 2016 (1050316) 2008-2010 Ford 6.4L FlowMax Lift Pump Kit (I-00359) - 1-2008-2010 Ford 6.4L PowerStroke FlowMax Lift Pump Kit Installation Instructions P/N# 1050316 PLEASE READ ALL INSTRUCTIONS

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0 PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0 MM September 21, 2012 TABLE OF CONTENTS Section Number DANGER INTRODUCTION AND TECHNICAL SPECIFICATIONS 1 CONTROL AND METERING DESCRIPTION 2 OPERATION

More information

XENON POWER SUPPLY 4000 Watt Gladiator IV

XENON POWER SUPPLY 4000 Watt Gladiator IV XENON POWER SUPPLY 4000 Watt Gladiator IV 220 Volt Equipment Type 62-00049 Rev. February 2003 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha, Nebraska 68112 USA

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions O N DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions Introduction The DT35 and DT55 series adjustable part circle and full circle rotary sprinklers are designed specifically for

More information

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL Copyright: January 5, 2009 Revised: November 24, 2014 Serial No. 0901189 - Gripnail Corporation An Employee Owned Company 97 Dexter Road East Providence,

More information

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm. float switches Mechanical Float Switch Mechanically activated float switches offer a reliable low current control for dewatering applications. How It Works The mechanical float switch control will turn

More information

ValveMate 7000 Controller Operating Manual

ValveMate 7000 Controller Operating Manual A NORDSON COMPANY ValveMate 7000 Controller Operating Manual Steady Test Clear Time Set Fast Slow POWER RUN SETUP CYCLE A NORDSON COMPANY VALVEMATE 7000 Run Setup Purge Program Fast Slow Time Set Pressure

More information

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011 -

More information

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of

More information

ELECTRICAL SYSTEM RP-7

ELECTRICAL SYSTEM RP-7 ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three

More information

Model 550 Series Vibration Switches

Model 550 Series Vibration Switches OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...

More information

TIN KNOCKER TK H1652 Hydraulic Shear

TIN KNOCKER TK H1652 Hydraulic Shear TIN KNOCKER TK H1652 Hydraulic Shear INSTRUCTIONS & PARTS DIAGRAM TAAG INDUSTRIES CORP. 1550 SIMPSON WAY, ESCONDIDO, CA 92029 Tel: (800) 640-0746 Fax: (760) 727-9948 Website: www.tinknocker.com Email:

More information

Water Valve Shutoff. WVS Water Valve Shutoff

Water Valve Shutoff. WVS Water Valve Shutoff Water Valve Shutoff Monitors flooding from leaking or broken water line Automatic control of main water supply line Form C Relay output for external monitoring devices Visual and audible status indicators

More information

SNOW PLOWS OPERATION & MAINTENANCE MANUAL

SNOW PLOWS OPERATION & MAINTENANCE MANUAL SNOW PLOWS OPERATION & MAINTENANCE MANUAL INTRODUCTION TABLE OF CONTENTS Page PLEASE READ ALWAYS INSIST ON GENUINE AIR-FLO PARTS & ASSESSORIES QUICK-SILVER SNOW PLOW Please get to know your Quick-Silver

More information

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting PAGE 1 This document outlines questions to ask and components to check during TES troubleshooting. More detailed troubleshooting procedures are available in the TES Troubleshooting Guide. 1. Flow Light

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.

More information

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option HT-10000 Dielectric Withstand Tester 0-10000 Volts AC Output 25mA Leakage Option Instruction Manual COMPLIANCE WESTUSA Dear Customer: Congratulations! Compliance West USA is proud to present you with your

More information

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve Technical Bulletin TB-ACV-LFF11RFP LEAD FREE * LFF11RFP Flood Protection Shut Down Valve Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when continuous discharge from

More information

ClassicSeries Compressor Installation

ClassicSeries Compressor Installation ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note:

More information

PowerAir Compressor Installation

PowerAir Compressor Installation PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model

More information

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES SYSTEM CONCEPT When not transferring fuel, the pressure in the underground closed piping system of a gasoline station may fall due

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

Battery Control Center - Diesel

Battery Control Center - Diesel Service Manual CAUTION: All servicing of the Battery Control Center should be done only by a qualified Service Technician. Inadvertent shorts inside the Battery Control Center could result in severe damage

More information

Kit Drain Water Tempering Kit

Kit Drain Water Tempering Kit Kit 90092 - Drain Water Tempering Kit for Models DH2000 and MD2000 Kit Parts: Refer to the parts list below to ensure all the parts necessary for the installation are in your kit. Item Part Description

More information

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart Instruction & Parts Manual This Manual Covers P/N 33271 P/N 33271

More information

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION SECTION 3.00 ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION Be sure that the clutch, circuit breaker, or other main power transmission device is disconnected. Generators develop voltage as soon as the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

Multi-Tank Submersible Pump Install Manual

Multi-Tank Submersible Pump Install Manual Multi-Tank Submersible Pump Install Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. LSF Start-Up Instructions 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. 2) PRE-START-UP: Be sure there is water in the pump. Bleed air at all high points

More information

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Pump Curves...2 Pump End Assembly...3 Disassembly...3 Installation...4

More information