E.S.P. Embedded Sensing Probes for Motor Brushes

Size: px
Start display at page:

Download "E.S.P. Embedded Sensing Probes for Motor Brushes"

Transcription

1 E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609

2 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check for the most recent version of this manual (in Adobe Acrobat PDF format).

3 Table of Contents 1.0 Introduction General Information Description of Equipment Equipment List Installation Connection Instructions Application Guidelines Troubleshooting E.S.P. Brush Monitor... 9 i

4 ii

5 1.0 Introduction This manual contains information on the proper installation, maintenance and operation of the E.S.P. brush monitor system. A complete description of equipment, application guidelines, troubleshooting guide, connection instructions and a list of replacement parts are included. 2.0 General Information The purpose of the E.S.P. brush monitor system is to provide an automatic early warning of the need to replace brushes on DC motors and generators, regardless of the manufacturer. Unique patented E.S.P. brushes contain Embedded Sensing Probes providing a short brush signal when the brushes approach the end of their useful life. At that point, enough brush life remains so that brush replacement may be scheduled within a reasonable amount of time. The E.S.P. monitor, upon receiving the short brush signal, illuminates a red warning light and energizes a relay which may be connected to an external device such as an audible alarm. The E.S.P. brush monitor system reduces maintenance cost by eliminating visual inspections of brush length, protects equipment against costly damage, and guards against equipment downtime and lost production. 3.0 Description Of Equipment The E.S.P. brush monitor system consists of an electronic brush monitor, a matched set of E.S.P. brushes and standard brushes, E.S.P. signal and signal return isolation networks and accessories for installation. Each E.S.P. brush monitor system is designed to be used in conjunction with DC motors and generators with armature voltages from 90 up to 1000 volts DC operating on generated DC or rectified power source. E.S.P. brushes are equipped with patented Embedded Sensing Probes and are mounted in the motor. A minimum of one E.S.P. brush per pole is required. These brushes provide an electrical output signal to the E.S.P. monitor when an E.S.P. probe comes into contact with the commutator and a minimum of 10% rated voltage is applied to the armature. The probe depth is determined by the design and construction of the brush and brushholder. A current limiting isolation network mounted within the motor or the motor terminal box connects the E.S.P. brushes to the E.S.P. monitor. There are two ESP Brush Monitors available. One is designed to monitor a single motor, providing for maximum flexibility in location as well as the simplest possible installation. The other design monitors up to six motors having any combination of armature voltages through 1000 VDC. Each monitor is packaged in a wall-mounted NEMA 4 enclosure and is powered by 115 volts AC 50/60 Hz. All monitors are equipped with green pilot lights to indicate that each monitor circuit is on and functioning properly. A red warning light and relay for each monitored motor actuates in response to the E.S.P. signal from the E.S.P. brushes. A push to test feature provides a momentary signal to the input of the E.S.P. monitor and allows a means to test the operation of the red warning lamp and relay for each circuit. The E.S.P. signal is a low level signal (current limited to 5mA, by the motor-mounted current limiter isolation network) and, as such, should be wired to the monitor using signal wiring techniques. Should you choose to mount this monitor in or close to the motor control, this signal wire should be routed from the motor terminal box to the monitor along with motor armature leads in the armature power wire conduit or wire tray. A signal return is provided by a second current limiting isolation network connected across A1 and A2. This circuit may be mounted in the control cabinet. See Figure 1. Figure 1 Connection Diagram for Normal Installation Of E.S.P. Monitor This circuit may be mounted in the motor terminal box along with the E.S.P. isolation network. A twisted pair must be used to connect the E.S.P. signal and signal return to the monitor. See Figure 2. Figure 2 Alternate Connection Diagram for Remote Mounting Of E.S.P. Monitor A matched set consisting of E.S.P. and standard brushes constructed of the same carbon material and grade must be procured as a complete set from Baldor. 4.0 Equipment List Purchased from Baldor: 1. E.S.P. Monitor 2. E.S.P. Signal Isolation Network (See Table 1) (including extra wire, connectors and splices which may be required in certain applications as indicated in this instruction manual). 3. Signal Return Isolation Network (See Table 1) 4. Complete set of E.S.P. and Standard Brushes. Supplied by User: 1. Signal Wire- #16 AWG Minimum, 600 Volt, and Class B (105 C) for systems up to 600 armature voltage or #16 AWG minimum 1000 volt and Teflon insulated (200 C) 1

6 for systems with armature voltage. The available systems cover a wide range of DC armature voltages from 90 through 1000 volts. Use applicable E.S.P. signal and signal return isolation networks as indicated in Table 1. Table 1 Armature Voltage Number of Poles Maximum No. of E.S.P. Brushes E.S.P. Signal Isolation Network Signal Return Isolation Network 91 v 2 or RD R v 2 or S S v 2, 4 or RB S v 2, 4 or RC v RD v 2, 4 or lT T v 2, 4 or V T v 2, 4 or RA T v 4, 6 or A Warning: Before attempting to install this E.S.P. brush monitor system, disconnect and lockout all sources of incoming power to the control and motor. Electrical shock can cause serious or fatal injury. Only qualified personnel should attempt the installation, operation and maintenance of this equipment. 5.0 Installation The installation procedures vary slightly between the single motor monitor unit and the six motor monitor unit. To assure proper installation refer to the following sections: Single-Motor Monitor - see 5.1 to 5.5 Multi-Motor Monitor- see 5.6 to Installation Of Single Motor Monitor 1. Disconnect and lock out all incoming drive power to the control and motor. 2. Determine the installation pattern of the E.S.P. brushes and standard brushes using Table 2 as a guide. Table 2 Important note: If brush mountings have been altered to allow for brush staggering, brushes on adjacent poles must be installed in the same track (See Figure 3). Figure 3 3. There are two different isolation networks (E.S.P. signal isolation network and the signal return isolation network) which must be installed. There are two ways to install each type of network. First determine your application then refer to the proper installation procedure. E.S.P. Signal Isolation Network This network may be installed in the motor terminal box (see Figure 4) with the two E.S.P. signal isolation network leads (marked W+ and W-) extending into the motor, around the frame and connecting to the E.S.P. brush probe leads or it may be installed inside the motor frame (see Figure 8) with the output lead (W1) extending into the motor terminal box. After selecting the mounting method, refer to the appropriate installation procedure as follows: Mount E.S.P. Signal isolation network in motor terminal box- see 5.2 Mount E.S.P. Signal isolation network inside the motor frame - see 5.3 Signal Return Isolation Network The signal return isolation network may be connected in the motor terminal box (see 5.4) or it may be connected to the motor controller (see 5.5). 2

7 5.2 Instructions For Mounting E.S.P. Signal Isolation Network In Motor Terminal Box 1. Remove top and side hand hole covers. 2. Remove all existing brushes from motor and discard. 3. Replace one or more brushes as required on each stud with new E.S.P. brushes equipped with embedded sensing probes (see Table 2). Then complete the set with additional new standard brushes of the same grade material. 4. Use Plastic Ties provided to secure E.S.P. brush probe leads to top field coil or motor wire harness with lead tie as required. Provide sufficient slack in E.S.P. brush probe lead to allow for brush wear as brush moves down in brushholder box. 5. Secure E.S.P. signal isolation network in terminal box. Then run leads W+ and W- into motor frame (see Figure 4). 6. Cut W+ and W- leads as necessary, leaving sufficient length to reach each E.S.P. brush probe lead, allowing for slack. Strip wire, and crimp-on the male connectors provided. 7. Connect E.S.P. signal isolation network leads to E.S.P. brush probe leads per connection diagram (see Figure 5). For example: On 2 pole motors connect 1 positive E.S.P. brush probe lead to lead on E.S.P. signal isolation network marked W+, and 1 negative E.S.P. brush probe lead to lead on E.S.P. signal isolation network marked W-. On 4, 6 or 8 pole machines, there are 2-, 3 or 4 positive leads and 2, 3 or 4 negative leads respectively. On motors with 4, 6 or 8 poles, or more than one E.S.P. brush per stud, the E.S.P. brush probe leads shall be connected to the E.S.P. signal isolation network leads per Figure 6 or Figure 7. Figure 4 3

8 E.S.P. Brush Probe Lead Connection Diagram For E.S.P. Signal isolation network wiring instructions, refer to wiring diagrams. Figure 6 and Figure 7. Figure 5 Figure 6 4

9 Figure 7 Caution: Assure that E.S.P. brush probe leads from positive and negative poles are not inter-connected. This can cause line to line shorting of the motor, resulting in damage to control equipment and the E.S.P. monitor. 8. Connect E.S.P. signal lead (marked W1) to additional signal wire and run to E.S.P. monitor and connect at terminal 102 (additional signal wire to be provided by user). 9. Replace top and side hand hole covers. Record part numbers of E.S.P. and standard brushes on motor label A (as provided) and adhere to hand hole cover. 10. Install Signal Return Isolation Network see 5.4 or 5.5 (Single Motor Monitor) or See 5.6 (Multi Motor Monitor). Warning: Attempting to use E.S.P. Brushes without the network will place armature power limited only by the capabilities of the drive control on to the E.S.P. Output signal lead which can result in personal injury and/or equipment damage. Confirm that the motor has been equipped with an E.S.P. isolation network. This network which may be either fastened to the motor frame or mounted in the motor terminal box, received input from the E.S.P. brushes (minimum one per stud) and provides, as its output, a signal indicating a short brush condition of any E.S.P. Brush. Its output is a single wire mark e d W1. This network limits the output current on W1 to a maximum of 5 milliamperes under either normal or fault conditions. 5

10 Instructions for mounting signal return isolation network to the motor controller -see 5.4 Instructions for mounting signal return isolation network in motor terminal box. -see 5.3 Figure 8 Motor Terminal Installation Box (2 Pole Motor Illustrated) 5.3 Instructions For Mounting E.S.P. Signal Isolation Network In Motor Frame 1. Remove top and side hand hole covers. 2. Remove all existing brushes from motor and discard. 3. Replace one or more brushes as required on each stud with new E.S.P. brushes equipped with embedded sensing probes (see Table 2). Then complete the set with additional new standard brushes of the same grade material. 4. Use plastic ties provided to secure brush monitor E.S.P. signal isolation network to top field coil or motor wire harness with lead ties as required (see Figure 4). 5. Bring single lead (marked W1) from E.S.P. signal isolation network into motor terminal box. Then connect additional signal wire and run E.S.P. signal lead to E.S.P. monitor and connect at terminal 102 (additional signal wire to be provided by user). 6. Cut W+ and W- leads as necessary, leaving sufficient length to reach each E.S.P. brush probe lead, allowing for slack. Strip wire, and crimp-on the male connectors provided. 7. Connect E.S.P. brush probe leads to E.S.P. signal isolation network leads per connection diagram (see Figure 5). For example: On 2 pole motors, connect 1 positive E.S.P. brush probe lead to lead on E.S.P. signal isolation network marked W+, and 1 negative E.S.P. brush probe lead to lead on E.S.P. signal isolation network marked W-. On 4, 6, or 8 pole machines there are 2, 3 or 4 positive leads and 2, 3 or 4 negative leads respectively. On motors with 4, 6, or 8 poles, or more than one E.S.P. brush per stud, the E.S.P. brush probe leads shall be connected to E.S.P. signal isolation network leads per Figure 6 or Figure Make sure all E.S.P. probe leads and E.S.P. signal isolation network leads are tied in such a manner so they will not get tangled in any rotating parts. Provide sufficient slack in E.S.P. brush probe lead to allow for brush wear as brush moves down in brushholder box. 9. Replace top and side hand hole covers. Record part numbers of E.S.P. and standard brushes on motor label R (as provided) and adhere to hand hole cover. 10. Install Signal Return Isolation Network see 5.3 or 5.4 (Single Motor Monitor) or 5.6 (Multi-Motor Monitor). Instructions for mounting signal return isolation network in motor Terminal box. - see 5.4 Instructions for mounting signal Return isolation network to motor controller - see

11 5.4 Instructions For Mounting Signal Return Isolation Network In Motor Terminal Box Install the E.S.P. signal return isolation network in the motor terminal box using the following procedures (see Table 1 for part number). 1. Connect leads marked A1 and A2 to armature leads in terminal box. 2. Secure signal return isolation network inside the motor terminal box using plastic ties # F as necessary. 3. Run signal return lead and E.S.P. signal lead as twisted pair to E.S.P. monitor (see Figure 2). 4. Connect E.S.P. signal lead (marked W1) to terminal 102 and signal return lead to terminal Instructions For Mounting Signal Return Isolation Network To Motor Controller Install the E.S.P. signal return isolation network in the control using the following procedures (see Table 1 for part number). 1. Connect leads marked A 1 and A2 to terminals A1 and A2 in motor controller. Refer to Figure Secure network to inside cabinet or panel using # X anchors and plastic ties # F as required. 3. Run signal return lead to E.S.P. monitor and connect at terminal 101 (see Figure 1). 5.6 Installation Of Multimotor Monitor If you have purchased a Multi-Motor Monitor from Baldor, you will be able to monitor up to six (6) motors of varying armature voltages through 1000 VDC. 1. Disconnect and lock out all incoming drive power to the control(s) and motor(s). 2. Determine the installation pattern for each motor of the E.S.P. brushes and standard brushes using Table 2 as a guide. 3. There are two different isolation networks (E.S.P. signal isolation network and the signal return isolation network) which must be installed. There are two different ways to install each type of network. Therefore, first determine your application and then refer to the referenced installation procedure. E.S.P. Signal Isolation Network This network may be installed in the motor terminal box (see Figure 4) with the two E.S.P. signal isolation network leads (marked W+ and W-) extending into the motor, around the frame and connecting to the E.S.P. brush probe leads or it may be installed Inside the motor frame (see Figure 8) with the output lead (W1) extending into the motor terminal box. After selecting the mounting method, refer to the appropriate installation procedure as follows: Mount E.S.P. signal isolation network in motor terminal boxsee 5.2 Mount E.S.P. signal isolation network inside the motor framesee Instructions For Mounting The E.S.P. Signal Isolation Network In The Motor Terminal Box Repeat 5.2 for each motor to be monitored. 5.8 Instructions For Mounting The E.S.P. Signal Isolation Network In The Motor Frame Repeat 5.3 for each motor to be monitored. 5.9 Instructions For Mounting The E.S.P. Signal Isolation Network In The Motor Terminal Box Repeat 5.4 for each motor to be monitored Instructions For Mounting The E.S.P. Signal Isolation Network In The Drive Controller Repeat 5. 5 for each motor to be monitored. Figure 8 E.S.P. Brush Monitor System Connections SIGNAL RETURN ISOLATION NETWORK The signal return isolation network may be connected in the motor terminal box (see 5.4) or it may be connected to the motor controller (see 5.5). 7

12 6.0 CONNECTION INSTRUCTIONS 1. To verify the proper operation of the E.S.P. signal current limiter isolation network, disconnect leads on the E.S.P. signal isolation network. Using a conventional ohmmeter, measure the resistance from W+ to W1, then W- to W1. The resistance values should read as follows: Rated Armature Voltage 90 VDC VDC VDC VDC Resistance Measured 20KΩ ± 10% 56KΩ ± 10% 220KΩ ± 10% 360KΩ + 10% Reconnect the E.S.P. signal isolation network lead(s) disconnected to perform this test. 2. Confirm that the E.S.P. signal wire and signal return wire have been routed from the motor to the E.S.P. monitor. Refer to 4.0 equipment list for proper wire specification. If the signal return network is mounted in the motor or motor terminal box, the signal and signal return leads must be a twisted pair to the E.S.P. monitor. 3. Connect 115VAC line to monitor terminals 188 and If used, the monitor output relay can be wired from the monitor into customer circuitry using terminals 241, 242 and 243. Terminal 242 is a common connection. Terminal 241 provides a normally closed contact. Terminal 243 provides a normally open contact (see Figure 9). NOTE: If the power source brought to the contacts of this relay remains energized even with main input power to the cabinet disconnected, wiring to the relay contacts must be done with yellow wire to indicate a foreign circuit source. A warning legend plate, indicating that these auxiliary contacts receive power from a source not disconnected with the disconnection of main incoming drive power, has been provided with this system. This legend plate, required by N.E.C., must be mounted on the door of the drive cabinet. If an incoming line circuit breaker with a thru-the-door operating handle has been installed into the drive, this legend plate should be mounted near the breaker. 5. A push to test feature provides a momentary signal to the input of the E.S.P. monitor and allows a means to test the operation of the red warning lamp and relay. 8.0 Troubleshooting In the event that neither the green pilot light or the red warning light are illuminated on the monitor, one of three conditions may exist: 1. No 115 volts AC power. Check power source. 2. Either one or both lamps have failed. Check and/or replace bulb(s). Lamp Replacement: To replace lamp(s), unscrew red or green lens and remove bulb(s) from lens cavity. Replace with a standard #327 bulb, then reinstall red or green lens in monitor. Care should be exercised to ensure 0 ring seal on lens is not damaged. 3. The E.S.P. brush monitor system has malfunctioned. IMMEDIATE ACTION SHOULD BE TAKEN TO ACTIVATE A VISUAL MONITORING SYSTEM AS THE E.S.P. BRUSH MONITOR SYSTEM IS NO LONGER MONITORING BRUSH WEAR. Contact Baldor District Office. Caution: This motor is now equipped for use with an E.S.P. Monitoring System. Replace brushes as necessary with the proper complement of E.S.P. and standard brushes. The E.S.P. system will function only if all carbon brushes in each application are constructed of the same grade of material. All E.S.P. and standard brushes in each application must be procured as a matched set from your Baldor District Office. 7.0 Application Guidelines The user should note the following operating characteristics of the E.S.P. brush monitor system: 1. The short brush signal will occur providing that at least 10% armature voltage is present. The monitor may not provide consistent indication of a short brush condition at armature voltage of less than 10% of maximum. 2. Relay contacts in this system are rated to carry 0.5 amperes resistive or 0.25 amperes inductive current at 120 VAC. When using the relay to energize inductive loads (relay coils, etc.) a suppressor (Baldor P/N A or equivalent R-C suppressor) must be wired across the load for contact protection. 3. This monitor does not latch. Armature voltage of 10% or greater must be present for indication to take place. 8

13 9.0 E.S.P. Brush Monitor Single-Motor Monitor P/N R Qty. Description Part Number 1 Cover A 1 Base A 1 Cover Gasket A 1 Hinge Kit K-10 1 Red Lens A 1 Green Lens B 2 Light Sockets R 2 Lamps F 1 Pushbuttons D 1 P/B Seals E 1 PC Boards S 1 Mounting Plate A 1 Legend Nameplate R 1 Nameplate Gasket C 4 Cover Mtg. Screws A 1 Caution Label A 1 Warning Label A 1 Danger Label A 1 Motor Label A Multi-Motor Monitor P/N R Qty. Description Part Number 1 Cover A 1 Base A 1 Cover Gasket A 1 Hinge Kit K-10 6 Red Lens A 6 Green Lens B 12 Light Sockets R 12 Lamps F 6 Pushbuttons D 6 P/B Seals E 6 PC Boards S 1 Mounting Plate A 1 Legend Nameplate R 1 Nameplate Gasket C 6 Cover Mtg. Screws A 1 Caution Label A 1 Warning Label A 1 Danger Label A 6 Motor Label A Key 1) Carbon Probe 2) Insulator 3) Carbon Probe Contact Surface 4) Commutator Surface 5) Copper Conductor 6) Motor Brush The contact portion of the Embedded Sensing Probe is a miniature carbon probe (1) covered by an insulating sleeve (2). This insulated sleeve isolates the probe s conductive surface from the current flow in the brush until the carbon probe contact surface (3) engages the commutator surface (4). An insulated copper conductor (5) is, in turn, embedded into the miniature carbon brush. This entire assembly is inserted into the motor brush (6) to a statistically determined depth so that the E.S.P. signal allows you time to schedule brush replacement. Many factors can affect brushwear. Changing environment, humidity, load, variable brushholder spring tension, will all affect actual brushwear. Therefore, Baldor strongly recommends that brush replacement be scheduled at the earliest practical time following the E.S.P. signal. 9

14 10

15 Baldor Sales Offices

16 Baldor Electric Company P.O. Box 2400, Fort Smith, AR U.S.A., Ph: , Fax , International Fax Baldor Electric Company MN609 All Rights Reserved. Printed in USA. 2/13

BALDOR MN413 Brakes Manual

BALDOR MN413 Brakes Manual BALDOR MN413 Brakes Manual http://www.manuallib.com/baldor/mn413-brakes-manual.html The DODGE D-Series motor brakes are manufactured to NEMA standards for mounting to C-face and double shafted motors.

More information

MODEL ELC-12/40-CVM-D BATTERY CHARGER

MODEL ELC-12/40-CVM-D BATTERY CHARGER NATIONAL RAILWAY SUPPLY MODEL ELC-12/40-CVM-D BATTERY CHARGER Installing, Operating and Service Instructions for the ELC-12/40-CVM-D Solid State Charger PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING

More information

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS The original TOMMY GATE hydraulic lift Assembling the Auxiliary Battery Box 1. Remove the cover from the auxiliary battery box by removing the two nuts and

More information

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8030 MANUAL PART NUMBER JANUARY 2011. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF CONTENTS

More information

PBA Series Prelube Controls

PBA Series Prelube Controls VARNA Products Engineered Innovation PBA Series Prelube Controls Simple, Compact, Industrial Full featured control for running prelube from the control or from a remote station Easy internal wiring connections

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 40-75 HP @ 230 VAC and 75-150 HP @ 460 VAC Model Numbers: 906FK1101 and 906FK1201 Instruction Manual D2-3330-2! ATTENTION:

More information

Quick Connection Panel (QCP) Installation Guide

Quick Connection Panel (QCP) Installation Guide Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical

More information

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS TJ STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS page DESCRIPTION AND OPERATION STARTER MOTOR... 2 STARTER RELAY... 3 STARTING SYSTEM... 1 DIAGNOSIS AND TESTING STARTER MOTOR... 8 STARTER MOTOR NOISE

More information

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999 /2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table

More information

3 Phase Smart Controller

3 Phase Smart Controller 3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products to 5 Tons Accessory Electric Heaters Cancels: IIK 564A--1 IIK 564A-- 11-01 Installation Instructions Electric Heaters 5 0 kw NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing air conditioning equipment

More information

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO 1/17 Installation & Operating Manual MN781 Table of Contents Chapter 1 Introduction Introduction...

More information

INSTRUCTIONS. w w w. h d o n l i n e s h o p. d e ENGINE GUARD-MOUNTED FOG LAMP KIT 1WARNING -J02798 REV Installation.

INSTRUCTIONS. w w w. h d o n l i n e s h o p. d e ENGINE GUARD-MOUNTED FOG LAMP KIT 1WARNING -J02798 REV Installation. INSTRUCTIONS -J0798 REV. 9-4-00 Kit Number 689-98B General ENGINE GUARD-MOUNTED FOG LAMP KIT Installation This kit fits all models equipped with Harley-Davidson -/4 in. ( mm) diameter front engine guards,

More information

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

I-BFV.KIT Butterfly Valve Gear Operator Replacement

I-BFV.KIT Butterfly Valve Gear Operator Replacement SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before

More information

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions DEH 40026 Installation Instructions g ProTrip Conversion Kits For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION GE Conversion Kits are designed for upgrading existing

More information

Model No. SB1B-14 Linear Standby Regulator. B & C Specialty Products P.O. Box B Newton, KS (316)

Model No. SB1B-14 Linear Standby Regulator. B & C Specialty Products P.O. Box B Newton, KS (316) Installation Instructions for Model No. SB1B-14 Linear Standby Regulator With Over-Voltage Protection B & C Specialty Products P.O. Box B Newton, KS 67114 (316) 283-8000 SB1B-14_Install, Rev. A (12/12/14)

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz. 103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

STARTER SYSTEM TESTING 5.6

STARTER SYSTEM TESTING 5.6 STARTER SYSTEM TESTING 5.6 ON-MOTORCYCLE TESTS b088x5x Starter Relay Test NOTE Starter relay test also applies to ignition and key switch relays.. See Figure 5-5. Locate starter relay. The relay is attached

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

STARTER SYSTEM TESTING 5.6

STARTER SYSTEM TESTING 5.6 STARTER SYSTEM TESTING 5.6 ON-MOTORCYCLE TESTS Starter Relay Test NOTE Starter relay test also applies to ignition and key switch relays.. See Figure 5-5. Locate starter relay. The relay is attached to

More information

MODEL ELC-12/60-D BATTERY CHARGER

MODEL ELC-12/60-D BATTERY CHARGER *32198* NATIONAL RAILWAY SUPPLY Installing, Operating and Service Instructions for the 12/60 Solid State Charger MODEL ELC-12/60-D BATTERY CHARGER PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

PATENT PENDING. Phone: (877) Operation and Service Manual

PATENT PENDING.   Phone: (877) Operation and Service Manual PATENT PENDING Phone: (877) 544-2291 Operation and Service Manual 2 IMPORTANT NOTICE This document contains information intended to aid in the proper installation, operation, and maintenance of the product

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller Introduction: Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller The following is a set of instructions for retrofitting a Model 98 Digital

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products 2 to 5 Tons Accessory Electric Heaters Cancels: IIK 564A-24-2 IIK 564A-24- -02 Installation Instructions Electric Heaters 5 20 kw NOTE: Read the entire instruction manual before

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious

More information

RU SERIES UPGRADE TempAssure Compatible

RU SERIES UPGRADE TempAssure Compatible RU SERIES UPGRADE TempAssure Compatible This converter section has been designed as a converter section replacement in the following MagneTek or Parallax Power Supply series products and models with DC

More information

LPT50BRD (8x11x3 Enclosure)

LPT50BRD (8x11x3 Enclosure) LPT50BRD (8x11x3 Enclosure) TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN The LPT50BRD is a field repairable switch. Warranty covers defective parts only.

More information

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

section-page Table 1. Transfer switching device ratings. Conditional short circuit current Operator s Manual 7000 Series ATS Automatic Transfer Switching Equipment D design 30 through 200 amperes TABLE OF CONTENTS section-page INSTALLATION... 1-1 Enclosures and Mounting... 1-1 Power Connections...

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand

More information

SAFE & SECURE ACTUATOR PRODUCT MANUAL

SAFE & SECURE ACTUATOR PRODUCT MANUAL INDELAC CONTROLS SAFE & SECURE ACTUATOR PRODUCT MANUAL Product Description: The Safe & Secure Series Actuator is a quarter turn Open/Close Actuator with Battery Backup Power ALL IN ONE! No more mounting

More information

SECTION MOTOR CONTROLLERS

SECTION MOTOR CONTROLLERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph

More information

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.

More information

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75 Cascade CD101 Auto-Start Controller Installation and Operations Manual 00-02-0594 2018-02-15 Sections 40 & 75 In order to consistently bring you the highest quality, full featured products, we reserve

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

CONTROL FEATURES AVAILABLE OPTIONS

CONTROL FEATURES AVAILABLE OPTIONS Vari Speed A2000 TABLE OF CONTENTS Control Features Options Application Data Operating Condition s Control Ratings Chart Mounting Dimensions Installation and Wiring Typical Wiring Diagram Schematic (Block

More information

P70, P72, and P170 Series Controls for High Pressure Applications

P70, P72, and P170 Series Controls for High Pressure Applications Installation Instructions P70 Issue Date 0918 P70, P72, and P170 Series Controls for High Pressure Applications Application P70, P72, and P170 Series Controls for High Pressure Applications provide high-side

More information

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present Installing the Base Plate 1. Examine the interior and exterior

More information

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES FILE 29-900 Instructions for Combination Bypass Isolation and Transfer Switches 100-1000 Amps APPLICATION The Cutler-Hammer combination Bypass Isolation and Transfer Switches are listed under Underwriters

More information

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-0 effective 6/6/0 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex

More information

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R THE RELIANCE Fast/Tran IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by a qualified electrician thoroughly familiar with all

More information

3 in 1 TRAIL CHARGER with LOCKOUT

3 in 1 TRAIL CHARGER with LOCKOUT Owner s Manual P/N: 283821 500 3 in 1 TRAIL CHARGER with LOCKOUT 283821 01 Version 2.04 07/05/2011 Owners Manual Operation Installation Wiring Diagram Troubleshooting Parts Breakdown 1 GENERAL OPERATION

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present Installing the Base Plate 1. Examine the interior

More information

P70, P72 and P170 Series Controls for High Pressure Applications

P70, P72 and P170 Series Controls for High Pressure Applications Installation Instructions P70 Issue Date October 16, 2002 P70, P72 and P170 Series Controls for High Pressure Applications Application P70, P72 and P170 Series Controls for High Pressure Applications provide

More information

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC 10/16 Supplement to Installation & Operating Manual Any trademarks used in this manual are the property of their respective

More information

F O R M. Installation and Maintenance Manual for FCR Equipped Motors and Gearmotors. 9055E Revised October 2015

F O R M. Installation and Maintenance Manual for FCR Equipped Motors and Gearmotors. 9055E Revised October 2015 Installation and Maintenance Manual for FCR Equipped Motors and Gearmotors Power Transmission Solutions Regal Beloit America, Inc. 7120 New Buffington Road Florence, KY 41042 Application Engineering: 800

More information

Outdoor Enclosure Power System ENC X100MP48F20

Outdoor Enclosure Power System ENC X100MP48F20 Outdoor Enclosure Power System ENC673034-1X100MP48F20 Manual MA015152A1 Issue 1 Oct 2010 Copyright 2010 Myers Power Products, Inc. Part# A015152A1 MA015152A1 Iss1 Page 1 of 22 Dimensions Outdoor Enclosure

More information

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation

More information

Quick Start Guide TS 910 & TS 920

Quick Start Guide TS 910 & TS 920 Quick Start Guide TS 910 & TS 920 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

FLOAT BATTERY CHARGER

FLOAT BATTERY CHARGER Operating and Service Instructions AT10 SERIES MICROPROCESSOR-CONTROLLED FLOAT BATTERY CHARGER SINGLE PHASE INPUT PRE-AT10.1 CONFIGURATION (units shipped prior to 12/2001) JA0102-00 Rev. 11-2001 HOW TO

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER TO-161 073085 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER 6184-3..-.-.._. HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373

More information

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module. Instruction manual Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module Installation operation maintenance E50001-F710-K378-V6-4A00 www.usa.siemens.com/sdv7 Hazardous voltages and stored

More information

BC141, BC142, BC142-5 & BC142-6 DC Control

BC141, BC142, BC142-5 & BC142-6 DC Control BC141, BC142, BC142-5 & BC142-6 DC Control 5/17 Installation & Operating Manual MN704 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

Model DE-3 Air Release Heads Parts List

Model DE-3 Air Release Heads Parts List Issue/Rev. 0.0 (1/14) Smith Meter Air Eliminator Model DE-3 Air Release Heads Parts List Bulletin MN03021 Contents Section 1 Introduction... Page 2 Principle of Operation... Page 2 Section 2 Installation...

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 4000 Series ATS Automatic Open-Transition Transfer Switches D design 30 230A, J design 260 600A, H-design 800 1200A, G-design 1600 4000A, F-design 4000A DANGER is used in this manual

More information

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service Installation Instructions VA-908x Code No. LIT-12011566 Issued August 24, 2009 Applications The VA-908x Series Electric

More information

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS MANUAL NUMBER: 64073 REV: 2 DATE: October 3, 2006 INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS AMERICAN BATTERY CHARGING, INC. P.O. BOX 17040 28 MAPLE AVENUE SMITHFIELD,

More information

Outdoor Enclosure Power System ENC X100MP48F20-AC6

Outdoor Enclosure Power System ENC X100MP48F20-AC6 Outdoor Enclosure Power System ENC673034-1X100MP48F20-AC6 Manual MA015151A4 Issue 1 Nov 2010 Copyright 2010 Myers Power Products, Inc. Part# A015151A4 MA015151A4 Iss1 Page 1 of 24 Dimensions Outdoor Enclosure

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL FS Series Rolling Fire Door Operators CORPORATION GENERAL NOTES TO REDUCE THE RISK OF SEVERE INJURY OR DEATH, READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS

More information

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN Form 1254 BRAKETRON Electronic Motor Brake Instructions SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN TABLE OF CONTENTS SECTION TITLE PAGE I. Introduction 1 II. Specifications 1 III. Principles

More information

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions. Models beginning with MO, MK, 7B, 6S, 6F or 5B The Mini Meter Product Description Technical Specifications Installation Instructions February 28 th, 2013 1. Product Description...2 1.1 General Description...2

More information

Model 550 Series Vibration Switches

Model 550 Series Vibration Switches OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO) Operator s Manual Series 386 Electrically Operated Non Automatic Switches J design 600 amps DANGER is used in this manual to warn of high voltages capable of causing shock, burns, or death. WARNINGisusedinthismanualtowarn

More information

Technical Manual. DLM Module. This manual should remain with the unit.

Technical Manual. DLM Module. This manual should remain with the unit. Technical Manual DLM Module This manual should remain with the unit. Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this

More information

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Graham TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Vari Speed S1000 Instruction Manual TABLE OF CONTENTS Introduction 4 Unit Features 5 Operating Conditions 6 Specifications 7 Ratings

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s) ISIMET DLA Controller Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Application: The DLA

More information

M9/D (-020 thru -022) M11/D (-020 thru -022)

M9/D (-020 thru -022) M11/D (-020 thru -022) M/D (-020 thru -022) Item Description / Page Includes A Main Enclosure top cover / display panel assembly, leveling feet, hinge cover panels (side / back / base) B Reservoir / Drain Tube condensing coil,

More information

Installation Sheet January, 2016 Supersedes February, 2013

Installation Sheet January, 2016 Supersedes February, 2013 s Installation Sheet January, 016 Supersedes February, 013 E87010-A0104-T003-A6-CLM0 Lighting and Heating Contactor 30 Amp, 3, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions

More information

Battery Operation. Battery Construction. Battery State Of Charge. Battery Load Test. Battery Rating Systems 2/14/12

Battery Operation. Battery Construction. Battery State Of Charge. Battery Load Test. Battery Rating Systems 2/14/12 Battery Operation Batteries, Charging and Donald Jones Brookhaven College Batteries convert chemical energy into electrical energy During discharge the battery s plate composition is changed During charging

More information

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE 3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the

More information