Installation Instructions for Residential Satic Saver (Single Phase) Product: ES1PN. June 28, 2011 Tech Write up - Version 1.7

Size: px
Start display at page:

Download "Installation Instructions for Residential Satic Saver (Single Phase) Product: ES1PN. June 28, 2011 Tech Write up - Version 1.7"

Transcription

1 Installation Instructions for Residential Satic Saver (Single Phase) Product: ES1PN June 28, 2011 Tech Write up - Version Connery Way, Ste A Missoula, MT SATIC Connery Way, Ste A, Missoula, MT (406)

2 1-Phase Wiring Instructions - Version1.7 Installation instructions for Residential Satic Saver (Single Phase) Please read this sheet prior to installation of the Residential Satic Saver. Locations and Information: 1. The Satic Saver was designed to be installed at the load center (breaker panel). 2. Many homes have multiple breaker panels and the Satic Saver can be installed on any breaker panel, providing there is space for the dedicated breaker. 3. The Satic Saver is designed to condition ALL phases of power in the home, regardless of installation location (phase-to-phase and each phase-to-neutral). 4. If there are no spaces available at the meter base or breaker panel, a subpanel can be installed for a dedicated breaker. 5. The Satic Saver single phase MUST be installed on a dedicated two-pole 15 amp breaker. Piggybacking is against national building codes. 6. The Satic Saver is enclosed in a NEMA 3R box allowing it to be installed indoors or outdoors, but it CANNOT be installed under water. Satic External Junction Box Example WARNING HAVE YOUR SATIC SAVER INSTALLED BY A LICENSED ELECTRICIAN. INSTALLING ELECTRICAL EQUIPMENT MAY RESULT IN SHOCK, SERIOUS INJURY, OR EVEN DEATH. WARNING ELECTRICAL SHOCK MAY OCCUR, DO NOT OPEN. THERE ARE NO SERVICEABLE PARTS. Installation Instructions: 1. Install a two-pole 15 amp breaker. 2. Use the knock-outs on the panel or drill a hole into the box, allowing access to the breaker. Mount box in secure location with access to breaker using UL conduit. 3. Secure the two leads (red and black wires) of the ES1PN Satic Saver, one on each side of the breaker. 4. Secure the white wire from the ES1PN Satic Saver to the neutral bar in the panel. Leave breaker in OFF position until power is restored to the panel. 5. Reinstall the panel cover securely. 6. Flip the dedicated breaker to ON. A blue light on the Satic box will be illuminated. 7. If the light remains off, call customer support at SATIC. The Energy Saver can be placed on an existing empty breaker or a new 2-pole, 15 amp breaker (not included). Red Black White - Warranty - The Satic Saver has a three year warranty from date of installation. Please fill out the warranty card completely and return after installation is complete.

3 Installation Instructions for Residential Satic Saver (Three Phase) Product: ES3PN & ES3PP Tech Write up Version Connery Way, Ste A Missoula, MT SATIC Connery Way, Ste A, Missoula, MT (406)

4 3-Phase Wiring Instructions - Version 1.7 Installation instructions for Residential Satic Saver (Three Phase) Please read this sheet prior to installation of the Residential Satic Saver. Locations and Information: 1. The Satic Saver was designed to be installed at the load center (breaker panel). 2. Many homes have multiple breaker panels and the Satic Saver can be installed on any breaker panel, providing there is space for the dedicated breaker. 3. The Satic Saver is designed to condition ALL phases of power in the home, regardless of installation location (phase-to-phase and each phase-to-neutral). 4. If there are no spaces available at the meter base or breaker panel, a subpanel can be installed for a dedicated breaker. 5. The Satic Saver three phase MUST be installed on a dedicated three-pole 15 amp breaker. Piggybacking is against national building codes. 6. The Satic Saver is enclosed in a NEMA 3R Satic External Junction Box Example box allowing it to be installed indoors or outdoors, but it CANNOT be installed under water. WARNING HAVE YOUR SATIC SAVER INSTALLED BY A LICENSED ELECTRICIAN. INSTALLING ELECTRICAL EQUIPMENT MAY RESULT IN SHOCK, SERIOUS INJURY, OR EVEN DEATH. WARNING ELECTRICAL SHOCK MAY OCCUR, DO NOT OPEN. THERE ARE NO SERVICEABLE PARTS. Installation Instructions: 1. Install a three-pole 15 amp breaker. 2. Use the knock-outs on the panel or drill a hole into the box, allowing access to the breaker. Mount box in secure location with access to breaker using UL conduit. 3. Secure the three leads (red, blue, and black wires) of the ES3PP Satic Saver, one on each pole of the dedicated breaker. 4. Secure the white wire from the ES3PN Satic Saver to the neutral bar in the panel. Leave breaker in the OFF position until power is restored to the panel. 5. Reinstall the panel cover securely. 6. Flip the dedicated breakers to ON. Blue lights on the Satic boxes will be illuminated. 7. If the light remains off, call customer support at SATIC. The Energy Saver can be placed on an existing empty breaker or a new 3-pole, 15 amp breaker (not included). Red Blue Black White - Warranty - The Satic Saver has a three year warranty from date of installation. Please fill out the warranty card completely and return after installation is complete.

5 1PP Motor Direct Diagram To Breaker Box on Line Side ES1PP Contactor Satic ES1PP Example Contactor To Motor/Pump/Etc. on Load Side Satic, Inc. 2011

6 3PP Motor Direct Diagram To Breaker Box on Line Side ES3PP Contactor Example 3 Pole, 20 Amp Breaker To Motor/Pump/Etc. on Load Side Satic, Inc. 2011

Super-Shammee II V 3-Phase Touchless Spotfree Drying System. Installation Manual

Super-Shammee II V 3-Phase Touchless Spotfree Drying System. Installation Manual Installation Manual (For Model Super-Shammee II Wall/Attic Mount Dryer Unit) Diskin Systems Inc. 9550 South IL Rt 31 Algonquin, IL 60102 (815)-276-7288 WARNING:Read entire installation manual before attempting

More information

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems INSTALLATION GUIDE For Carrier/Bryant Residential Power Systems For 100 Amp Automatic Transfer Switch/Load Center Model: KGATX0116100 16 circuit installed with 16kW generators. This Automatic Transfer

More information

Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK

Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK Warning: The Gen/Tran Switched Neutral Kit should be installed by a professional electrician familiar with electrical wiring and codes,

More information

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH STANDBY POWER FURNACE SWITCH Easy/Tran TF Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has been manufacturing transfer switches and equipment

More information

This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit.

This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit. This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit. Saves on installation time and cost, in many cases up to 50% compared to traditional transfer switch installations.

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

Australian Wiring Instructions:

Australian Wiring Instructions: Australian Wiring Instructions: Generator/Switch Wiring: Remove the generator controller fascia and identify wire #44 going to the circuit breaker in the external connection box, this wire is the active

More information

METERING REQUIREMENTS

METERING REQUIREMENTS METERING REQUIREMENTS KUA will not accept a non-securable service trough entrance. That is, all enclosed conductors prior to the meter (line side) will be securable by and accessible to KUA personnel only.

More information

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators Owner s Manual Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators DANGER is used in this manual to warn of risk of electrical shock

More information

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch. 3560 NE ROZENE WAY BREMERTON, WASHINGTON 98311 (530) 316-1049 Generator Transfer Switch Model; HTS15-MAN & HTS15-MAN-2 Tools Needed For Installation Power drill Wire stripper and cutter (10 to 14 gauge)

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

Learning Module 10: Loadcenters. 101 Basic Series

Learning Module 10: Loadcenters. 101 Basic Series Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential

More information

Quick Start Guide TS 910 & TS 920

Quick Start Guide TS 910 & TS 920 Quick Start Guide TS 910 & TS 920 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

EMERY SKY SUSPENDED LED LUMINAIRE

EMERY SKY SUSPENDED LED LUMINAIRE EMERY SKY SUSPENDED LED LUMINAIRE IP20 DRY LOCATION 120V- 277V AC SAFETY & WARNINGS 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS 2. Install in accordance with national and local electrical code regulations.

More information

Electric Range installation manual

Electric Range installation manual Electric Range installation manual This manual is made with 100% recycled paper. imagine the possibilities ENGLISH Thank you for purchasing this Samsung product. To receive more complete service, please

More information

IMPORTANT SAFEGUARDS

IMPORTANT SAFEGUARDS INSTRUCTION MANUAL NON-INTERRUPTIBLE AC INVERTER SYSTEM MODEL EAC FTM 350 FOR EMERGENCY LIGHTING POWER IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed,

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

SAFE & SECURE ACTUATOR PRODUCT MANUAL

SAFE & SECURE ACTUATOR PRODUCT MANUAL INDELAC CONTROLS SAFE & SECURE ACTUATOR PRODUCT MANUAL Product Description: The Safe & Secure Series Actuator is a quarter turn Open/Close Actuator with Battery Backup Power ALL IN ONE! No more mounting

More information

MaxLite StaxMax LED Flood Lights

MaxLite StaxMax LED Flood Lights Operating Instructions MaxLite StaxMax LED Flood Lights Input Rating 120V-277V 50/60Hz (347/480v optional) Wet Location Rated IP65 Operating temperature -22⁰F to 105⁰F General Safety Information 1. READ

More information

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R THE RELIANCE Fast/Tran IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by a qualified electrician thoroughly familiar with all

More information

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO) Owner s Manual Series 165P Power Transfer Load Center 125 amps, 1 phase, 240 V ac, 12 or 20 load spaces for automatic 2 wire start generators DANGER is used in this manual to warn of risk of electrical

More information

Heat Tracing Sales Mt. Airy, Maryland Controls

Heat Tracing Sales Mt. Airy, Maryland Controls Heat Tracing Line Sensing Control Panels Solid State Relay Output Rated 30 Amps or Two-Pole Contactor Control Output Universal Inputs NEMA 4/4X Enclosure Ground Fault Alarm/Trip Monitor or GFI Circuit

More information

Vigilant Automatic Transfer Switches

Vigilant Automatic Transfer Switches Vigilant Automatic Transfer Switches 100A to 1250A The Vigilant Series ATS is designed to automatically transfer critical loads in the event of a power outage. It consists of a simple, rugged design while

More information

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Owner s Manual For Automatic Transfer Switch 50 & 100 Amp Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Register your Generac product at: WWW.GENERAC.COM 888-436-3722

More information

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO20-115 PRO20-115RD 115-Volt AC PRO20-115AD Automatic Diesel Nozzle PRO20-115MD Manual Diesel Nozzle PRO20-115PO Pump Only PRO20-115RD For Remote Dispensing Systems

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual DC V GPM Fuel Transfer Pump Kit User s Manual Distributed by: TRACTOR SUPPLY COMPANY 0 VIRGINIA WAY BRENTWOOD, TN 0 For customer support, call: ---90 www.tractorsupply.com MADE IN CHINA MODEL NUMBER: 0

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Installation Manual. Rev

Installation Manual. Rev Installation Manual ChargePro 620 Charging Station is a trademark of SemaConnect, Inc. All other products or services mentioned are the trademarks, service marks, registered trademarks or registered service

More information

Supply-Side PV Connections

Supply-Side PV Connections Perspectives on PV Supply-Side PV Connections by John Wiles Plan reviewers and inspectors throughout the country are seeing increasing numbers of supply-side connected utility interactive photovoltaic

More information

O & M Manual for the EATON Generator Ready Loadcenter

O & M Manual for the EATON Generator Ready Loadcenter O & M Manual for the EATON Instructional Booklet New Information Description Page 1. Introduction............................... 2 2. Receiving, Handling, and Storage................ 4 3. Equipment Description........................

More information

Owners Installation, Operation, and Safety Manual

Owners Installation, Operation, and Safety Manual Owners Installation, Operation, and Safety Manual Remote Dispensing Cabinets Models FR102PH FR302DP FR902DP FR910PM Tuthill Corporation 8825 Aviation Drive Ft. Wayne, IN 46809 (260) 747-7529 www.tuthill.com

More information

INSTRUCTIONS. Power Panel. Installation Instructions

INSTRUCTIONS. Power Panel. Installation Instructions Overview LuXout Shade 18 Output - For use with LuXout Shades NOTICE: This power supply is built-in fan on/off control circuit. Fan automatically works according to working temperature. SHOCK HAZARD Risk

More information

Installing Your 220v J-POD Kit

Installing Your 220v J-POD Kit Installing Your 220v J-POD Kit NOTE: There are two J-POD versions depending on your pump voltage - 110 volt and 220 volt. MAKE SURE YOU HAVE THE RIGHT VOLTAGE J-POD FOR YOUR. Using software and hardware

More information

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved. FLO Home TM X5 Model Installation Manual 2016 FLO Services Inc. All rights reserved. v161130:2013 Table of Contents Specifications 3 Safety Instructions 4 Planning your Installation 5 Box Contents 6 Installing

More information

n Ilation instructions Load Center Transfer TMOperator

n Ilation instructions Load Center Transfer TMOperator n Ilation instructions Load Center Transfer TMOperator -A A //_ Hazardous voltage that will cause death, serious injury or substantiai property damage. Turn off power supplying this equipment before working

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018. SUMMARY This bulletin introduces a new PG&E program that allows the installation of an electric meter socket adapter that will accept a wired connection directly from a residential customer s Photo Voltaic

More information

Turbine STEP System SIMPLEX OR DUPLEX

Turbine STEP System SIMPLEX OR DUPLEX 3649 Cane Run Road Louisville, KY 211-1961, USA 1-800-928-7867 1-502-778-2731 Fax: 1-502-774-3624 www.clarusenvironmental.com SECTION: C1.20.120 CL0019 0816 Supersedes 1212 Turbine STEP System SIMPLEX

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

PLASTIC FOLDING ARM KIT This kit is designed for the 1600 model barrier gate operators only. Recommended for low headroom applications.

PLASTIC FOLDING ARM KIT This kit is designed for the 1600 model barrier gate operators only. Recommended for low headroom applications. PLASTIC FOLDING ARM KIT This kit is designed for the 600 model barrier gate operators only. Recommended for low headroom applications. Kit Includes: Plastic Arms Attachment Assembly Clamp Locking Turnbuckle

More information

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection...

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection... .1 Contents Description Catalog Number Selection................ Enclosures............................ Cover Control.......................... Product Selection.................... Operation Non-Combination

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

Use and Care Guide.

Use and Care Guide. Model # Part # 53301111 L-40-802-SV-N-BZ 53301112 L-40-802-SV-N-W Use and Care Guide LED OUTDOOR RE LIGHT Questions, problems, missing parts? Call ETi SSL Customer Service 8:30 a.m. 5 p.m., EST, Monday

More information

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: 30A EVoCharge EVSE Model Number: EV072-300-001A Product Safety Certification: UL and cul Listed Description: SAE J1772 AC Level

More information

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

ChargePoint Gateway Installation Instructions

ChargePoint Gateway Installation Instructions ChargePoint Gateway Installation Instructions You must be a licensed electrician and complete online training (http://chargepointuniversity.netexam.com/) to become a ChargePoint Certified Installer, and

More information

Home Electrical Wiring. Getting the electricity from the main power lines to a location in the house

Home Electrical Wiring. Getting the electricity from the main power lines to a location in the house Home Electrical Wiring Getting the electricity from the main power lines to a location in the house 90% of BC power comes from Hydro There is potential energy stored in a water reservoir behind a dam.

More information

3.1. Residential Standby Power. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

3.1. Residential Standby Power. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .1 Residential Standby Power Transfer Switch Panels All Panels are Manufactured in the USA and Meet UL 1008 Product Description A transfer switch panel is a device that is mounted next to the loadcenter

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel 1/8 hp 300 500 1/8 hp

More information

ChargePro 620 Electric Vehicle Charging Station Installation Guide

ChargePro 620 Electric Vehicle Charging Station Installation Guide ChargePro 620 Electric Vehicle Charging Station Installation Guide Wall Mount Pole Mount Contents Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Cover Sheet Safety and Compliance Pedestal Mount Installation

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... - - - ASCO is there for you even when you re not - SERIES - SERIES SERIES -

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and

More information

Cetra. Ceiling Power Entry Installation (AEC1, AEC14, or AEC16)

Cetra. Ceiling Power Entry Installation (AEC1, AEC14, or AEC16) Figure A Power Pole Top Cap Trim Plate L Bracket (Long leg attached to top of panel) Ceiling Installation (AEC, AEC, or AEC) Recommended Tools Variable Speed Drill with Torque Option Pop Rivets Riveting

More information

ANZI Transfer Switch and Generator Wiring Installation Addendum

ANZI Transfer Switch and Generator Wiring Installation Addendum ANZI Transfer Switch and Generator Wiring Installation Addendum Reference all appropriate documentation. NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. THIS PRODUCT CAN BE INSTALLED BY THE

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

JUNCTION BOX FOR CATHODIC PROTECTION

JUNCTION BOX FOR CATHODIC PROTECTION JUNCTION BOX FOR CATHODIC PROTECTION Yuxi manufacture a serious type of junction box required for a cathodic protection system. Our junction box is designed to use reliably for onshore and marine environments

More information

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0 EVoInnovate EVSE Model Numbers: EVO32-300-001 & EVO32-300-002 User Manual & Installation Guide Revision 1.0 IMPORTANT SAFETY INSTRUCTIONS This document contains instructions and warnings that must be followed

More information

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1 N Power Box Opening Data Port Openings Rear View Front View Remove opening blanks on raceway cover for power and data. If panel contains no electric or data and is used as a pass-thru, leave opening blanks

More information

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL 13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,

More information

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally. This page left blank intentionally. 38 Chapter 4: Commercial Metering / January 2011 APPENDIX Glossary Approval Acceptable to the authority having jurisdiction. Associated equipment As related to metering

More information

INSTALLATION INSTRUCTION MANUAL

INSTALLATION INSTRUCTION MANUAL INSTALLATION INSTRUCTION MANUAL LED FLOOD LIGHT, 100-277VAC MODELS: SL923FLF-15W; SL923FLF-30W; SL923FLF-50W; SL923FLF-80W; SL923FLF-100W; SL923FLF-150W; SL923FLF-300W Model number parameter list: Model

More information

Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r

Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r Generac offers more options for transfer switches than any other manufacturer. The LTS switch is designed to allow for the most efficient

More information

75 KVA Transformer Power Distribution - Three Phase 480V to Single Phase 120/240V - Nema 3R

75 KVA Transformer Power Distribution - Three Phase 480V to Single Phase 120/240V - Nema 3R 75 KVA Transformer Power Distribution - Three Phase 480V to Single Phase 120/240V - Nema 3R Part #: MPD-480-4X125A-75K-5X240-8X120 MADE IN THE USA This Larson Electronics 75KVA Power Distribution Substation

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation! Demand Switch NEFA20 Plus Installation Guide Please read this entire guide before beginning the installation! Supplied Parts Protective Covers DIN Mounting Rail NEFA20 Plus Mounting Rail Spacer Warning

More information

MaxLite LED Enclosed & Sealed Jelly Jars

MaxLite LED Enclosed & Sealed Jelly Jars General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using

More information

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS MAGNITUDE LIGHTING C DIMMABLE DIM DOWN TO 1% CLASS 2 12V DC P/N: M20L12DC-AR Magnitude's M20L12DC-AR is the most compact LED driver on the market with a magnetic transformer core. It is equipped with two

More information

Enclosed Electric Rotary Screw Compressor Installation Guide

Enclosed Electric Rotary Screw Compressor Installation Guide Enclosed Electric Rotary Screw Compressor Installation Guide Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained. Warning: Read all installation

More information

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 16 1 AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using

More information

HIGH PERFORMANCE INDUSTRIAL GRADE

HIGH PERFORMANCE INDUSTRIAL GRADE HIGH PERFORMANCE INDUSTRIAL GRADE Rotary Phase Converters 240 VOLT SERIES AI INDUSTRIAL SERIES Operation & Installation Manual DANGER: HIGH VOLTAGE Electric shock could result in death or injury. Please

More information

10. METERING General Requirements

10. METERING General Requirements 10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,

More information

Quick Connection Panel (QCP) Installation Guide

Quick Connection Panel (QCP) Installation Guide Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch PD5200 SERIES PD5300 SERIES Member Progressive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com

More information

75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R V and 8 120V Outlets

75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R V and 8 120V Outlets 75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R - 6 208V and 8 120V Outlets Part #: MPD-480-200MB-75K-6X208-8X120 MADE IN THE USA This Larson Electronics 75KVA Power Distribution Substation

More information

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium Electric Drive Vehicle Infrastructure Training Instructor s Manual National Alternative Fuels Training Consortium Part 4: : Service Panel to Receptacle Overview of Service Panel The role of the service

More information

M-1115S Series Fuel Pump

M-1115S Series Fuel Pump SAVE THESE INSTRUCTIONS M-1115S Series Fuel Pump Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...3 Operation...4 Maintenance...5 Repair...5 Troubleshooting...9

More information

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Owner s Manual For Automatic Transfer Switch 100 Amp Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED: Register your Generac product at: WWW.GENERAC.COM 888-436-3722 Para español, visita:

More information

Battery Enclosure Installation Instructions

Battery Enclosure Installation Instructions MNBE-C Battery Enclosure Instructions Battery Enclosure Installation Instructions MNBE-C These instructions are for the installation of Midnite Solar Battery Enclosure models MNBE-C, MNBE-CL16 and MNBE-C8D

More information

SloanLED THINLED. Constant Current. Installation Guide

SloanLED THINLED. Constant Current. Installation Guide SloanLED THINLED Constant Current Installation Guide Product covered in this guide: ThinLED CC: Part Number Description 701228-18-A Amber ThinLED Constant Current 701228-18-B Blue ThinLED Constant Current

More information

AEROBAY INSTALLATION INSTRUCTIONS

AEROBAY INSTALLATION INSTRUCTIONS AEROBAY INSTALLATION INSTRUCTIONS AEROBAY IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical

More information

MaxLite LED UTILITY WRAP FIXTURES

MaxLite LED UTILITY WRAP FIXTURES General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Installation and Service Manual for Residential Series EVSE (Electric Vehicle Supply Equipment)

Installation and Service Manual for Residential Series EVSE (Electric Vehicle Supply Equipment) Supersedes August 2012 (Electric Vehicle Supply Equipment) Contents Description Page Installation guide.... 2 Important safety instructions please read... 2 Symbols and definitions... 2 About the charging

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

Electrical Equipment and Terminology

Electrical Equipment and Terminology Youth Explore Trades Skills Description Understanding the language of the electrical trade and knowing what electrical equipment is named and its purpose are very important. Anyone who is exposed to a

More information

Product Overview. Enclosure for batteries N PE/G. Battery (customer-provided - shown for reference only) Battery output terminals

Product Overview. Enclosure for batteries N PE/G. Battery (customer-provided - shown for reference only) Battery output terminals Product Overview Enclosure for Transformer Installation MGE TM Galaxy TM 3500 and Smart-UPS VT Enclosure for Batteries and Enclosure for Transformer 400 V Enclosure for batteries PE/G ; PE/G Unistruts

More information

JOCKEY PUMP CONTROLLERS

JOCKEY PUMP CONTROLLERS INSTALLATION AND MAINTENANCE MANUAL FOR JOCKEY PUMP CONTROLLERS 1 Table of Contents 1. Introduction 2. Installation 3. Technical Documents 2 JP-Manual-EN Table of Contents... 4 Introduction... 4 Types

More information