GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo.

Size: px
Start display at page:

Download "GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo."

Transcription

1 GEA Clean Rooms Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo Data & Facts ÉåÖáåÉÉêáåÖ=Ñçê=~=ÄÉííÉê=ïçêäÇ db^=eé~í=bñåü~åöéêë

2 Range of Application... 4 product line...4 Unit features and benefits... 4 Areas of application...4 Technical Description... 5 Unit variants...5 Principle of operation (FHM)... 6 Principle of operation (FHM P)... 6 Technical Data FHM... 7 V (FHM V)... 7 S (FHM S)... 8 for operating theatres (FHM O)... 9 Technical Data FHM POWER U (FHM PU) U Cool (FHM PUC) S (FHM PS) S Cool (FHM PSC) T (FHM PT) T Cool (FHM PTC) D Cool (FHM PDC) Components Standard components Casing Standard components with selection Filters Outlets Air supply source Control and measurement Lighting Accessories / optional components Side panels Air speed sensor Dwyer Photohelic manometer Sound attenuator PVC curtains PR GB Subject to changes K0-10/2013

3 Components Standard components Casing Fan(s)... Standard components with selection Filters Outlets Air supply source Control and measurement Lighting...20 Accessories / optional components Side panels Pre-filter...20 Fresh air supply...20 Valve assembly...21 Cooling coil...21 Air speed sensor Dwyer Photohelic manometer Sound attenuator PVC curtains Project Design Instruction Dimensions and tolerances Space for valve assembly Switch box Panel height Unit Type Code Unit Specification and Quote Text PR GB Subject to changes K0-10/2013 3

4 Range of Application product line The (FHM) product line represents a new generation of Fresh Heaven units for pressurized low-turbulence fields that combines full filtration with the operating mode for local air recirculation. It is intended for clean rooms with the highest requirements for uniform vertical air flow in the pharmaceutical industry, in aseptic operating theatres and similar areas of application. The unit is available as: Basic ( passive ) FHM version: Power ( active ) version with fans operating in recirculating-air mode: Unit features and benefits Full-area filtration uniform air flow low initial pressure drop of HEPA filters Complete construction performed in stainless steel (V2A~AISI304 as standard) resistant to disinfectants and mechanical damage V4A~AISI316L is optionally available Customized dimensions (10 mm grid) to suit the customer s needs Built-in linear LED lighting safe voltage, low power consumption, long service life Various outlet types Proprietary control unit An option to connect a fan module economical EC motors automatic constant air flow control (when filters are clogged) cooling in condensation-free mode as option Areas of application Standard design solutions for pharmaceutical industries and hospitals: Pharmaceutical industry Operating theatres Air flow speed m/s m/s Dimensions As required by customer x m Central passage Not provided For mounting surgical lighting Operating mode/air supply Recirculating mode (FHM Power) or supplied by air handling unit Supplied by AHU Material Stainless steel AISI 304 Zinc-coated steel sheet painted RAL 9010 Filter seal U-section Fluid Outlets Perforated stainless steel/single-layer PES fabric Single-layer PES fabric on aluminium frame 4 PR GB Subject to changes K0-10/2013

5 Technical Description Unit variants Various configurations are available for FreshHeaven MAXX (FHM) and different versions of FreshHeaven MAXX POWER (FHM P) are illustrated in the chart below. pharmaceutical industry aseptic operating theatres Design version Length of Power module [mm] Length of laminar area La [mm] Max. area of laminar flow [m 2 ] Height of casing [mm] Max. overall height H [mm] For details see: FHM V page 7 FHM S page 8 FHM O page 9 FHM PU page 10 FHM PUC page 11 FHM PS page 12 FHM PSC page 13 FHM PT page 14 FHM PTC page 15 FHM PDC page 16 PR GB Subject to changes K0-10/2013 5

6 Technical Description Principle of operation (FHM) Treated fresh air (from an air handling unit) or return air from the room is driven into a pressure chamber that is fitted with HEPA filters which are installed horizontally across the entire area of the pressurized field (fitted via clamps to a sealed stainless steel welded frame). After passing through the HEPA filters the cleaned air is pushed through outlets along individually arranged lighting to create a protection zone around a product or a patient. Afterwards, contaminated air is extracted from the room into a central air handling unit or supplied via the power module. The height of the FHM unit is 450 mm. The dimensions are determined according to the requirements of the facility system designer. A large-size unit is divided into sections which are supplied separately and connected together on site. The joints are designed to minimize their effect on the quality of laminar air flow and should be determined during the planning stage. Principle of operation (FHM P) A unit is equipped with the Power module, fan(s) for air recirculation and a pre-filter. The maximum size of the unit is limited by the volumetric flow rate of 12,000 m 3 /h, which at the average outlet speed of 0.45 m/s corresponds to the laminar air flow field area of approximately 7.4 m 2. If a water-based coil is added to the suction chamber, the maximum volumetric flow rate is reduced to approximately 8,000 m 3 /h, which at the average outlet speed of 0.45 m/s corresponds to the laminar air flow field area of approximately 4.9 m 2. 6 PR GB Subject to changes K0-10/2013

7 H=Hc Technical Data FHM V (FHM V) Air-supply connections are located on top of the casing. The connections are rectangular and are fitted with flanges. The position and dimensions of inlet connections must be determined and specified during the planning stage. Consider the recommended average air velocity at unit inlet of 3 m/s. L = La HEPA filters W LED light Technical Data: Max. outlet length for laminar flow La [mm] 4000 Total length L [mm] 4000 Height of casing Hc [mm] 450 Max. total height H [mm] 450 Total width W [mm] 4000 Max. area of laminar flow [m 2 ] 8.8 PR GB Subject to changes K0-10/2013 7

8 H=Hc Technical Data FHM S (FHM S) Air supply connections are located on the side of the casing. The inlet connections are rectangular and are fitted with flanges. The position and dimensions of inlet connections must be determined and specified during the planning stage. L = La HEPA filters W LED light Technical Data: Max. outlet length for laminar flow La [mm] 4000 Total length L [mm] 4000 Height of casing Hc [mm] 450 Max. total height H [mm] 450 Total width W [mm] 4000 Max. area of laminar flow [m 2 ] PR GB Subject to changes K0-10/2013

9 H=Hc Technical Data FHM for operating theatres (FHM O) A special design version for operating theatres. The basic version consists of two separate sections. The air supply connections are located on the opposite sides of the casing. After assembly, space is provided in the centre of the unit to enable installation of surgical lighting. Having passed through the HEPA filters air is made more uniform by passing through a single-layer polyester laminarizer stretched across an aluminium frame. The circumference of the laminarizer is lit from above by LED lighting integrated into the sides of the casing. A PVC curtain with an optional media bridge for supply connections may be installed around the unit. The mean outlet air speed is 0.24 m/s. L h HEPA filters La HEPA filters W w Technical Data: Max. outlet length for laminar flow La [mm] 3120 Total length L [mm] 3125 Height of casing Hc = Max. total height H [mm] 450 Height of air duct h [mm] 200 Total width W [mm] 3125 Width of air duct w [mm] 1500 Max. area of laminar flow [m 2 ] 9.7 PR GB Subject to changes K0-10/2013 9

10 W H = Hc Technical Data FHM POWER U (FHM PU) U is designed for installion into false ceilings (a horizontal suction grille mounted flush with the false ceiling). Air intake is performed via a perforated metal-sheet grille and a pre-filter and pushed by a fan into the pressurized chamber above HEPA filters. Filtered clean air is supplied downwards along lights through outlets. The suction chamber is separated from the laminar air flow field by a PVC curtain. L Power module with fan Pre-filter Suction grille Lp La HEPA filter Suction chamber Technical Data: Minimum Maximum Length of Power module Lp [mm] 500 Length of laminar flow La [mm] Total length L [mm] Height of casing Hc [mm] 550 Total height H [mm] 550 Total width W [mm] Suction chamber [mm] 500 Area of laminar flow [m 2 ] PR GB Subject to changes K0-10/2013

11 Technical Data FHM POWER U Cool (FHM PUC) U Cool is a U unit fitted with a water-based cooling coil. Coil pipes run into the rear wall (optionally to sides or upward); a valve assembly is available on request (installed outside the unit). L Water-based coil Valve assembly for coil (optional) Power module with fan H = Hc Pre-filter Suction grille HEPA filter Suction chamber W Technical Data: Minimum Maximum Length of Power module Lp [mm] 1000 Length of laminar flow La [mm] Total length L [mm] Height of casing Hc [mm] 550 Total height H [mm] 550 Total width W [mm] Suction chamber [mm] 1000 Area of laminar flow [m 2 ] PR GB Subject to changes K0-10/

12 Technical Data FHM POWER S (FHM PS) S is designed for installation below false ceilings (a vertical suction grille, the sides and front may be fitted with panels depending on the configuration type). Pre-filter Power module with fan L Suction grille Suction chamber H = Hc HEPA filter W Technical Data: Minimum Maximum Length of Power module Lp [mm] 650 Length of laminar flow La [mm] Total length L [mm] Height of casing Hc [mm] 550 Total height H [mm] 550 Total width W [mm] Suction chamber [mm] 650 Area of laminar flow [m 2 ] PR GB Subject to changes K0-10/2013

13 W H=Hc Technical Data FHM POWER S Cool (FHM PSC) S Cool is a S unit fitted with a water-based coil. Coil pipes run upward (optionally to sides), the valve assembly is available on request and installed outside the unit. Valve assemby for coil (optional) Pre-filter L Water-based coil Power module with fan Suction grille Suction chamber HEPA filter LED light Technical Data: Minimum Maximum Length of Power module Lp [mm] 1000 Length of laminar flow La [mm] Total length L [mm] Height of casing Hc [mm] 550 Total height H [mm] 550 Total width W [mm] Suction chamber [mm] 1000 Area of laminar flow [m 2 ] PR GB Subject to changes K0-10/

14 Ho Hc Technical Data FHM POWER T (FHM PT) T is a equipped with a fan module for recirculating air mode with air intake performed above the floor. The air duct is fitted with a pre-filter and up to four fans in a row. The maximum size of the unit is limited by the volumetric flow rate of 12,000 m 3 /h, which at the average outlet speed of 0.45 m/s corresponds to the laminar air flow field area of approximately 7.4 m 2. The maximum length of the laminar air-flow field La can be extended to approximately 3 metres. Power module with fan L HEPA filter Lp La Suction chamber Suction grille Pre-filter Technical Data: Minimum Maximum Length of Power module Lp [mm] 500 Length of laminar flow La [mm] Total length L [mm] Height of casing Hc [mm] 550 Overhead clearance height Ho [mm] Total height H [mm] Suction chamber [mm] 500 Area of laminar flow [m 2 ] PR GB Subject to changes K0-10/2013

15 Ho Hc Technical Data FHM POWER T Cool (FHM PTC) T Cool is an FHM POWER T unit fitted with a waterbased coil (optionally equipped with a valve assembly). Coil pipes run upward (optionally downward, to sides or backward), the optional valve assembly may be installed inside the unit. The maximum size of the unit is limited by the volumetric flow rate of approximately 8,000 m 3 /h, which at the average outlet speed of 0.45 m/s corresponds to the laminar air flow field area of approximately 4.9 m 2. The maximum length of the laminar air flow field La can be extended to approximately 2 metres. Valve assembly for coil (optional) Power module with fan L HEPA filter Lp Suction chamber Water-based coil Suction grille Pre-filter Technical Data: Minimum Maximum Length of Power module Lp [mm] 650 Length of laminar flow La [mm] Total length L [mm] Height of casing Hc [mm] 550 Overhead clearance height Ho [mm] Total height H [mm] Suction chamber [mm] 650 Area of laminar flow [m 2 ] PR GB Subject to changes K0-10/

16 Ho Hc Technical Data FHM POWER D Cool (FHM PDC) FHM PDC is equipped with fans installed in pairs above each other to increase the length of the laminar air flow field. The maximum size of the unit is limited by the volumetric flow rate of approximately 8,000 m 3 /h (two pairs of fans), which at the average outlet speed of 0.45 m/s corresponds to the laminar air flow field area of approximately 4.9 m 2. The minimum width of the module here is 1.25 m and the maximum length of the laminar air flow field La can approximately reach 4 metres. W Valve assembly for coil (optional) Power module with fans L HEPA filter La Lp Suction chamber Water-based coil Pre-filter Suction grille Technical Data: Minimum Maximum Length of Power module Lp [mm] 650 Length of laminar flow La [mm] Total length L [mm] Height of casing Hc [mm] 550 Overhead clearance height Ho [mm] Total height H [mm] Suction chamber [mm] 650 Area of laminar flow [m 2 ] PR GB Subject to changes K0-10/2013

17 Components Standard components Casing stainless steel sides and top panels welded and sealed frame made of stainless steel profiles pre-assembled delivery for fast commissioning easy maintenance and cleaning thanks to dismountable filter clamps and lights independent suspension height 450 mm sensors for measuring aerosol concentration from the pressure chamber (leak test) Standard components with selection Filters full filtration horizontal HEPA/ULPA filters H13/H14/(U15) low initial pressure drop filter frame from aluminium profiles varnished protective grille on the clean air side U-seal easy installation and replacement (from the bottom) easy cleaning (dismountable) filter clamps Outlets A choice of various outlets: electrochemically polished and perforated stainless steel (40 % clear surface) perforated steel (40 % clear surface) RAL 9010 painted single-layer polyester fabric laminarizer (aluminium frame + stainless steel edge) Air supply source Control and measurement central-plant air handling unit switch box is mounted on the side of the casing and has following dimensions: 300 (length) x 300 (height) x 150 (depth) mm control module made by Siemens ( Siemens Logo! ) pressure switch for HEPA filters power supply for LED lights OPTIONAL: outputs to the central control panel PR GB Subject to changes K0-10/

18 Components control panel is installed into a precast panel and performs following functions: air speed indication (in daily mode) too high / = nominal / too low HEPA filter replacement indication lighting switch OPTIONAL: air speed sensor see Accessories OPTIONAL: digital manometer (Photohelic) see Accessories Lighting powerful light-emitting diode (LED) by a leading global manufacturer compact dimensions (40 mm wide) smooth plastic U-shaped diffuser for optimum air flow economical, maintenance-free, long service life safe voltage 12 VDC (+ power supply 230 VAC) lighting intensity min. 500 lx (verification calculation) Accessories / optional components Side panels side panels (brushed stainless steel) Air speed sensor speed sensor for outlet air equipped with a stainless steel bracket for mounting on a partition wall. Dwyer Photohelic manometer As standard, the pressure drop is controlled by a differential pressure switch and indicated on the control panel. This optional sensor can be replaced by a Dwyer Photohelic manometer with an upper limit control feature and an analogue display. Sound attenuator PVC curtains For additional reduction of sound level an attenuator can be optionally selected. To minimize turbulences the use of a soft wall (e.g. PVC curtains) is recommended along the borders of the laminar air flow field. PVC curtains are necessary to maximize the laminar air flow zone. Two configuratiuons of PVC curtains are available: PVC curtains, thickness 5 mm PVC strip curtains with antistatic finish, thickness = 2 mm, width = 200 mm 18 PR GB Subject to changes K0-10/2013

19 Components Standard components Casing Fan(s) stainless steel sides and top panels welded and sealed frame from stainless steel profiles pre-assembled delivery for fast commissioning easy maintenance and cleaning thanks to dismountable filter clamps and lights independent suspension height 550 mm sensors for measuring aerosol concentration from the pressure chamber (leak test) suction from the front / side perforated suction grille: stainless steel or painted steel intelligent and powerful radial fans from a leading European manufacturer electronically commutated motors (ECM) energy efficiency: direct (low power consumption during fan operation) & indirect (low consumption = reduced heat load = reduced cooling demand) power supply voltage 230 VAC; soft-start / soft-stop ; t max = 50 C zinc-coated steel spiral casing automatic constant flow control (Constant Airflow, Total Airflow Control) Standard components with selection Filters full filtration horizontal HEPA/ULPA filters H13/H14/(U15) low initial pressure drop filter frame from aluminium profiles varnished protective grille on the clean air side U-seal easy installation and replacement (from the bottom) easy cleaning (dismountable) filter clamps Outlets A choice of various outlets: electrochemically polished and perforated stainless steel (40 % clear surface) perforated steel (40 % clear surface) RAL 9010 painted single-layer polyester fabric laminarizer (aluminium frame + stainless steel edge) Air supply source recirculating-air operating mode PR GB Subject to changes K0-10/

20 Components Control and measurement switch box is mounted on the side of the Power module and has following dimensions: 600 (length) x 300 (height) x 150 (depth) mm control module made by Siemens ( Siemens Logo! ) pressure switch for HEPA filters pressure switches for pre-filters power supply for LED lights OPTIONAL: outputs to the central control panel control panel is installed into a precast panel and performs following functions: air speed indication (in daily mode) too high / = nominal / too low HEPA filter replacement indication pre-filter replacement indication lighting switch air speed alarm (too high/low) switchover between the day (nominal flow) and night (reduced flow) mode OPTIONAL: air speed sensor see Accessories OPTIONAL: digital manometer (Photohelic) see Accessories Lighting powerful light-emitting diode (LED) by a leading global manufacturer compact dimensions (40 mm wide) smooth plastic U-shaped diffuser for optimum air flow economical, maintenance-free, long service life safe voltage 12 VDC (+ power supply 230 VAC) lighting intensity min. 500 lx (verification calculation) Accessories / optional components Side panels Pre-filter Fresh air supply side panels (brushed stainless steel) pre-filter in F5 filter class for treatment of return air unit can be equipped with a mixing function for fresh air supplied by central-plant air handling unit 20 PR GB Subject to changes K0-10/2013

21 Components Valve assembly The valve assembly consists of a three-way mixing valve with an actuator, a circulation pump and a balancing valve. Measurements are taken by a dew-point sensor, an inlet air thermometer, a condensation sensor and a room thermostat (not included). Cooling coil pipes and fins are made of copper, the casing is made of stainless steel. coil is designed on the basis of parameters provided by the customer (e.g. temperature and humidity of outlet air and heat load). The design calculation of the coil is included in the documentation. coil is operated in condensation-free mode. If the valve assembly is included, this function is provided by the software of the unit s control module; if the valve assembly is not ordered, the measuring and control components must be provided by the customer. Air speed sensor speed sensor for outlet air equipped with a stainless steel bracket for mounting on a partition wall. Dwyer Photohelic manometer As standard, the pressure drop is controlled by a differential pressure switch and indicated on the control panel. This optional sensor can be replaced by a Dwyer Photohelic manometer with an upper limit control feature and an analogue display. Sound attenuator PVC curtains For additional reduction of sound level an attenuator can be optionally selected. To minimize turbulences the use of a soft wall (e.g. PVC curtains) is recommended along the borders of the laminar air flow field. PVC curtains are necessary to maximize the laminar air flow zone. Two configuratiuons of PVC curtains are available: PVC curtains, thickness 5 mm PVC strip curtains with antistatic finish, thickness = 2 mm, width = 200 mm PR GB Subject to changes K0-10/

22 Project Design Instruction Dimensions and tolerances Consider manufacturing and assembly tolerances when designing the dimensions of the FHM field (theoretical tolerance of 5 mm is recommended). The picture shows a sample unit connected to a suspended false ceiling (KS false ceiling profile) and R panel (the joint is covered by a R30-radius profile). joint The maximum size of the unit is limited by structural, manufacturing and transport options and is determined upon agreement between the manufacturer, designer and end user. Large-size fields include more components with emphasis placed on minimizing the effect of joints between different parts and ensuring uniform air flow (see the cross section). The casing is suspended on M8 threaded rods using suspension lugs located outside the unit (access to the outer sides of the unit must be provided). The rod is screwed into a riveting nut located on the suspension lug and secured by an M8 nut. To set a horizontal position we recommend using specially-provided anchors. The project designer determines the type of material used for anchoring the unit to the ceiling. For detailed instructions on mounting contact your relevant sales office. Space for valve assembly When designing FHM PowerU Cool and PowerS Cool units, ensure enough space for the valve assembly. Consult the manufacturer for the location of these components and the required piping. Several units (installed next to each other) can be supplied from a single valve assembly (each coil must have its own balancing valve). We recommend using special wall panels equipped with ducts for piping; the valve assembly can be mounted in a wallpanel compartment (access through an inspection door). 22 PR GB Subject to changes K0-10/2013

23 Project Design Instruction Switch box When designing FHM and FHM PowerU units consider the required access to the switch box mounted on the unit side (e.g. provide an inspection tile in the false ceiling make sure to avoid contact with other lines, pipework and components). Consult the distributor for the location. Schematic wiring diagram of FHM unit L N PE Protected Power Supply 230 VAC calibre 6A/type C Service board for lights longer than 2 m Power supply for LED lights Pressure loss HEPA filter 2x hose false ceiling level FHM laminar field display air speed sensor (opt.) Monitoring panel / LOGO text display max. 10 m photohelic (optional) Schematic wiring diagram of FHMP unit Protected Power Supply 230 VAC for fans calibre 10A/type C/ 1 fan L N PE L N PE Protected Power Supply 230 VAC for cooling cable 6A/type B L N PE for lights longer 2 m Power supply LED lights external board terminal board term. board cooling relay cooling Protected Power Supply 230 VAC calibre 6A/type C pre-filter 2 hoses HEPA filter 2 hoses communication power supply fans Cooling Servo heating-cooling Circulating water pump Sensors cool water thermometer inlet air thermometer (T213) dewpoint sensor (T213) sensor condensation Service board false ceiling level FHM laminar field Power module air flow sensor (opt.) display max 10m photohelic (optional) thermostat Panel height If a partition wall is connected to FHM, such panels should not project more than 30 mm into the bottom edge of the laminar module (due to risk of damage by contacting piping or by-pass). PR GB Subject to changes K0-10/

24 Unit Type Code Example: F H M x x x 5 5 S P U C 0 A FHM Product designation Total length L [cm] Width W [cm] Total outlet H [cm] Casing R Perforated 35%, painted RAL 9010 S L Stainless steel perforated 40%, electrochemically polished Single-layer fabric laminarizer Air supply V S O P From above (supplied by AHU) From side (supplied by AHU) Version for operating theatres Via Power fan module Air suction U S T D O Suction from bottom Suction from side Suction at floor level Suction at floor level, extended reach For operating theatres (attenuators + mixing) Coil Without coil C With water-based coil Valve assembly A With valve assembly and measurement and control 0 Without valve assembly Accessories (can be combined) 4 Stainless steel AISI316L A Sound attenuators B PVC strip curtains with antistatic finish, thickness = 2 mm, witdh = 200 mm F S Side panels PVC curtains, thickness = 5 mm Ordering codes indicate only the basic data of the product (type, dimensions and features). When placing an order it is necessary to specify a range of other parameters such as the filter class, mean air outlet speed, front panels, etc. 24 PR GB Subject to changes K0-10/2013

25 Tender specification units of units Standard components Casing from stainless steel Standard components 450 mm 550 mm Fan(s) Casing from stainless steel Suction from the front / side Fan(s) perforated suction grille: stainless steel or painted steel Standard components with alternatives Standard components with selection Filters Filters HEPA H13 HEPA H13 HEPA H14 HEPA H14 ULPA U15 ULPA U15 Outlets Outlets electrochemically polished stainless steel perforated electrochemically polished stainless steel perforated (40 % of clear area) (40 % of free area) steel perforated (40 % of clear area) RAL9010 painted steel perforated (40 % of clear area) RAL9010 painted single-layer polyester fabric laminarizer (aluminium frame + stainless steel edges) Air-supply source single-layer polyester fabric laminarizer (aluminium frame + stainless steel edges) Air-supply source central-plant air handling unit central-plant air handling unit recirculating-air module Control and measurement Control and measurement Switch box 300 (length) x 300 (height) x 150 (depth) [mm] Optional with: outputs to the central control panel Switch box 600 (length) x 300 (height) x 150 (depth) [mm] Optional with: outputs to the central control panel Monitoring panel Monitoring panel with additional pre-filter replacement indication air-flow speed alarm (too high/low) switchover between the day (nominal flow) and night (reduced flow) mode Optional components Optional components Side panels Side panels side face panels (brushed stainless steel) side face panels (brushed stainless steel) Lights Lights powerful light-emitting diode (LED) powerful light-emitting diode (LED) Coil casing made of stainless steel, copper pipes and fins casing of stainless steel, copper pipes and fins Air-flow speed sensor Coil Air-flow speed sensor outlet speed sensor with stainless steel bracket outlet speed sensor with stainless steel bracket Dwyer Photohelic manometer Dwyer Photohelic manometer with upper limit control feature and an analogue display with upper limit control feature and an analogue display Sound attenuator PVC curtains Sound attenuator PVC curtains standard, thickness = 5 mm standard, thickness = 5 mm strips with antistatic finish, 2 mm thick, 200 mm wide strips with antistatic finish, 2 mm thick, 200 mm wide Valve assembly for FHM Power U Cool and Power S Cool units PR GB Subject to changes K0-10/

26 Notes 26 PR GB Subject to changes K0-10/2013

27 Notes PR GB Subject to changes K0-10/

28 We live our values. Excellence Passion Integrity Responsibility GEA Group is a global engineering company with multi-billion euro sales and operations in more than process technology. GEA Group is listed in the STOXX Europe 600 Index.

DATA & FACTS Clean Rooms Fresh Heaven MAXX Fresh Heaven MAXX POWER. Laminar Air-Flow Units for Industrial Applications and Ceiling Installation

DATA & FACTS Clean Rooms Fresh Heaven MAXX Fresh Heaven MAXX POWER. Laminar Air-Flow Units for Industrial Applications and Ceiling Installation DATA & FACTS Clean Rooms Laminar Air-Flow Units for Industrial Applications and Ceiling Installation Table of Contents Range of Application... 4 product line...4 Unit features and benefits... 4 Areas of

More information

FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA

FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA Fresh Breeze Fan-Filter Unit Range of Application... 3 Sizes... 3 Characteristics... 3 Fresh Breeze product line... 3 Areas of application... 3 Technical Data

More information

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...

More information

Laminar ceilings, exhaust columns, exhaust grilles

Laminar ceilings, exhaust columns, exhaust grilles Laminar ceilings, exhaust columns, exhaust grilles 1 Table of Contents: 1. Laminar ceilings general information... 3 2. Laminar ceilings design and operation principles... 4 3. Parameters of air in the

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL... 1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

Mobile recleanable HEPA filter units for a flow of m 3 / h

Mobile recleanable HEPA filter units for a flow of m 3 / h Mobile recleanable HEPA filter units for a flow of 3.000 m 3 / h Page 1/11 consisting of Mobile online recleanable HEPA filter block, Type M-RHF hightec 1 x 2 and Mobile air conveyor block, Page 2/11 RHF

More information

MiniRoom. Isolation cubicles flexibility with containment. Horizontal laminar flow of air for greater protection - positive or negative

MiniRoom. Isolation cubicles flexibility with containment. Horizontal laminar flow of air for greater protection - positive or negative MiniRoom Key Features Isolation cubicles flexibility with containment Custom built to your requirements Horizontal laminar flow of air for greater protection - positive or negative Electro-magnetic door

More information

Halton Rex 600 RE6 - Adaptable active chilled beam

Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces

More information

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7 HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION Exflow 28 Technical Specification Page 1 of 7 TECHNICAL SUMMARY Terminal Unit size 12-3 ¼ x 12-3 ¼ x 23 ¾ Terminal Unit weight 3527

More information

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms CG INLET CEILING Inlet ceiling with the laminar discharge flow for operating rooms Pleasant climate controllable as required Economical operation due to the point protection principle Extremely low number

More information

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words Tender for " CONSTRUCTION OF SUPER SPECIALITY HOSPITAL FOR GOVT. RAJAJI MEDICAL COLLEGE, MADURAI, TAMIL NADU HEATING VENTILATION AND AIR CONDITIONING WORKS NIT No. SRO/MKT/TH/289 Dated 02/07/2014 SL. No.

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation

More information

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand.

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand. 5.1.6 Fan Filter Unit (FFU) Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand. The FFU consists of the following components: -

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air

More information

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL. Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents CNVA Active floor convector Contents General description... 2 Advantages/Customer benefits... 2 Operation... 2 Description of the equipment... 3 Construction and Dimensions... 4 Accessories... 7 Connections...

More information

Swegon PACIFIC. Integrated climate beam

Swegon PACIFIC. Integrated climate beam Swegon Integrated climate beam www.eurovent-certification.com www.certiflash.com climate beam The is a high performance climate beam for installation in false ceilings. With high built-in flexibility,

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com PRODUCT BROCHURE Rectangular Displacement Diffuser RDW-FD smartemp.com DESCRIPTION The SMARTEMP Rectangular Displacement Diffuser, type RDW-FD (figure 1), produces a low velocity horizontal airflow pattern

More information

Warning. Document ref: A October 2015

Warning. Document ref: A October 2015 Sentry Door Curtain Installation, Operation & Maintainance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hampshire, P09 2JD Tel. 023 9247 7700 Email. info@dunham-bush.co.uk Document ref: 128-000-001-A

More information

Mediclean Complanate Ultra Clean Ventilation

Mediclean Complanate Ultra Clean Ventilation Mediclean Complanate Ultra Clean Ventilation complanate adjective com pla nate \ kämpləˌn t\ : made level : in one plane, flattened to a level surface : Latin complantus Mediclean Brandon Medical Brandon

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element Cleanroom systems Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

ACCESSORIES FOR DUCT FANS

ACCESSORIES FOR DUCT FANS FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.

More information

Ceiling induction diffuser DISA-300

Ceiling induction diffuser DISA-300 Ceiling induction diffuser DISA-300 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean One system, many solutions SIMPLY COST EFFECTIVE AND UNIVERSALLY APPLICABLE The perfect solution for separation of dust, particulate matter

More information

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1 X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser

More information

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise Product Brochure Fan coil units for suspended ceilings HyPower-Geko Energy efficient Powerful Hygienic Low noise Optimal climate: Hygienic. Efficient. Sustainable. The HyPower-Geko fan coil units generate

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation

More information

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes: Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-

More information

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE. GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE. GloveFAST Cyto Pharma/Aseptic Faster Isolator for Cytotoxic and Sterility test THE USER-FRIENDLY PRACTICAL

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

GEA filter program for turbo-machines. Gas turbines, compressors, motors and intake systems. Application brochures

GEA filter program for turbo-machines. Gas turbines, compressors, motors and intake systems. Application brochures GEA filter program for turbo-machines Gas turbines, compressors, motors and intake systems Application brochures engineering for a better world GEA Heat Exchangers Pressure drop Efficiency Air Eco2nomy

More information

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

BSC-1100IIA2-X is designed to meet the operating principles:

BSC-1100IIA2-X is designed to meet the operating principles: Introduction BSC-1100IIA2-X: Function and Operating Principle The Class II Biological Safety Cabinet is designed with inward air flow at a velocity to protect personnel, HEPA-filtered vertical laminar

More information

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

is with a variety of standard dimensions. Also our units can be custom engineered to any size. Bio Safety Cabinet biosafe TM is designed to provide personnel, environmental and product protection. Air flow is drawn around the operator into the front grille of the cabinet, which provides personnel

More information

downflo workstation dust collectors

downflo workstation dust collectors downflo workstation dust collectors Outperforms all other collectors Downflo WorkStations (DWS) fit anywhere on the plant floor and apply NO restrictions to worker movements or visibility. The full line

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES TECHNICAL CHARACTERISTICS PP30 OVERVIEW : The PP 30F (rear connection) and PP 31F (lateral connection) are employed for the diffusion of air using

More information

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY OVERVIEW CHARACTERISTICS APPLICATIONS KQ OVERVIEW : KQ high induction diffusers with variable geometry are a new type of air diffusion equipment. Their unique

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser DHL HEPA terminal filter diffuser Low turbulent flow diffuser (LTF), also suitable for exhaust Installation flush to the ceiling, also suitable for wall installation A measurement access through the diffuser

More information

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER The low profile (LFDCX) is designed to suit the critical requirements of modern cleanrooms. The LFDCX provides a means of controlling particle contamination

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

WGA Long throw nozzle grille

WGA Long throw nozzle grille Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...

More information

RHF hightec RH13 / H Mobile recleanable filter unit

RHF hightec RH13 / H Mobile recleanable filter unit Mobile recleanable filter unit Page 1/10 Page 2/10 RHF hightec Recleanable HEPA filter Basics Application Demanding requirements on the filter separation performance (HEPA) High particle concentration

More information

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with

More information

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I AmAir 300X AmAir 300X filters are constructed with AAF's totally unitized, double wall, moisture resistant die-cut beverage frame. The media

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY VARIABLE GEOMETRY OVERVIEW CHARACTERISTICS APPLICATIONS KQ OVERVIEW : KQ high induction diffusers with variable geometry are a new type of air diffusion equipment. Their unique deflector adjustment system

More information

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery DATA & FACTS Unit Heaters MultiMAXX HB Quick Selection and Fast Delivery Table of Contents MultiMAXX HB Unit Type Code... 3 About this Catalogue... 4 Overview of Capacity... 5 Unit Description... 6 Unit

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

LINEAR SLOT DIFFUSERS

LINEAR SLOT DIFFUSERS OVERVIEW CHARACTERISTICS APPLICATIONS OVERVIEW : The series linear diffusers allow to manage high air flows with minimum pressure losses and generated noise power. They allow to fully make use of the induction

More information

VT-SENSOR AIR VELOCITY AND TEMP

VT-SENSOR AIR VELOCITY AND TEMP home VTSENSOR AIR VELOCITY AND TEMP Ultra low velocity pressure measurement Traceable Calibration Certificate Excellent repeatability Self compensating zero Climate chamber compensated Long term span stability

More information

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules FOREMOST IN AIR FILTRATION TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules Bulletin: PB1500-0511 General Flanders TH Series HEPA/ULPA Filter Modules are lightweight

More information

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems DS 10 E 01.018 Preliminary remarks Where workplaces or production facilities have to be kept

More information

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE PRODUCT SELECTION DATA Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers 09PE Translation of the original document N 20030, 02.2017 Use 09PE The 09PE range is particularly

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

OptimAir NF. Active Chilled Beam OptimAir NF. Nov OptimAir NF Active Chilled Beam OptimAir NF Functions The OptimAir active chilled beam is a two-way induction type air-conditioningunit that is designed for integrated installation, mounted directly in

More information

Splash-proof Terminal HEPA Filter

Splash-proof Terminal HEPA Filter Splash-proof Terminal HEPA Filter Type GTS Overview The Splash-proofed Terminal HEPA Filter GTS is designed and tested to extract a Minipleat -Media Pack, available in different heights, with a new application

More information

Swegon PACIFIC. Integrated climate beam

Swegon PACIFIC. Integrated climate beam Swegon Integrated climate beam www.eurovent-certification.com www.certiflash.com climate beam The is a high performance climate beam for installation in false ceilings. With high built-in flexibility,

More information

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE Translation of the original document N 20033, 03.2015 Drycoolers Use Drycoolers in this range are mainly designed

More information

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE. GloveFAST Cyto/Aseptic Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE. GloveFAST Cyto/Aseptic Faster Isolator for Cytotoxic and Sterility test COMMON FEATURES CONSTRUCTION Full body of the unit and

More information

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES Swegon PACIFIC Integrated climate beam QUICK FACTS The PACIFIC is a high performance climate beam for installation in false ceilings. With high built-in flexibility, it is designed to meet today s needs

More information

DAC - Conical Diffuser. Halton DAC. Conical diffuser

DAC - Conical Diffuser. Halton DAC. Conical diffuser Halton DAC Conical diffuser Coanda effect provided with a wide range of air flow rates, thanks to the special profile of the diffuser blades Diffuser adapted for variable air flow Supply in four directions

More information

Cross Flow Heat Exchanger H352

Cross Flow Heat Exchanger H352 Cross Flow Heat Exchanger H352 H352 Cross Flow Heat Exchanger Shown With Optional Plain Tube of H352A fitted. Allows Investigation Of Plain And Finned Cross Flow Heat Exchangers. Expandable Free & Forced

More information

Ceiling induction diffuser DISA-601

Ceiling induction diffuser DISA-601 Ceiling induction diffuser DISA-601 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

Excelair. Every filter is created to perfection!

Excelair. Every filter is created to perfection! Excelair. Every filter is created to perfection! Since1982 HEPA FILTERS Filters are engineered & constructed for providing ultra clean air to protect clean rooms, pharmaceutical companies, hospitals, food

More information

FlowAir CATALOG.

FlowAir CATALOG. FlowAir CATALOG www.flowairfilters.com FPR Filter 2 The FPR is a Vcells Filter type. Especially designed to remove fine dust, smoke and bacteria. The FPR is suitable for air conditioning installations.

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation Halton CCE Adaptable active chilled beam for exposed installation Combined cooling, heating, and supply air unit for exposed installation Ideal solution for applications where good indoor environment,

More information

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk

More information

Duct Nozzle Diffuser. L e

Duct Nozzle Diffuser. L e Duct Nozzle Diffuser L-08-1-08e Contents Application Construction Safety instructions Contents Application Construction Safety instructions 2 Dimensions 3 Quick selection for ducts with 1 to 3 rows of

More information

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions Sound attenuating exterior wall grille QUICK FACTS Excellent noise attenuation A robust grille that withstands severe climatic conditions Available in a number of different materials Technical description

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - 09PE Translation of the original document N 20030, 03.2015 Use The 09PE range, available

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information