EST GROUP DC /96 REV 8 03/03 PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS
|
|
- Andrea Merritt
- 6 years ago
- Views:
Transcription
1 PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA CPI / Perma Plugs are part of the Pop-A-Plug Tube Plugging System. Unlike other tube plug designs, and under the proper conditions, CPI / Perma Plugs can be passed through the length of a straight heat exchanger tube and successfully installed at the far end of the tube without having direct access to both tube ends. This procedure outlines the information required to evaluating a heat exchanger for the Through-the-Tube plugging procedure, the limitations of the technique, and the installation process. PIN RING ON NOSE END CPI/PERMA PLUG IT IS NORMAL TO SEE 3-4 THDS EXPOSED BREAKAWAY (REMOVE PRIOR TO INSTALLATION) PIN RING BREAKAWAY (REMOVE PRIOR TO INSTALLATION) PLUG SIZE & MATERIAL DESIGNATOR ARE STAMPED ON END OF PIN "C" DENOTES CRS, "S" DENOTES SS, "B" DENOTES BRASS (2) SERRATION PLUG WITH NOSE PIN ONLY (3) SERRATION PLUG ALL OTHER SIZES WARNING! SUCCESSFULLY INSTALLING CPI / PERMA BY PASSING THEM THROUGH-THE- TUBE REQUIRES THAT THE OPERATOR CAREFULLY FOLLOW THIS PROCEDURE. THE OPERATOR SHOULD BECOME FAMILIAR WITH THIS PLUGGING PROCEDURE AND POSSESS A CLEAR UNDERSTANDING OF HOW TO INSTALL CPI / PERMA AT THE NEAR END BEFORE ATTEMPTING THROUGH-THE-TUBE PLUGGING. EVALUATING THE APPLICATION - INFORMATION REQUIRED: 1. Tube Size. What is the actual tube ID? 2. The tube-to-tubesheet connection. Is the tube-to-sheet connection expanded, welded, or both? If the tube is expanded the length of the expanded area is required to determine the position where the plug will be installed within the tube. CPI / PERMA MUST NEVER BE INSTALLED IN THE TRANSITION ZONE BETWEEN EXPANDED AND UNEXPANDED AREA OF THE TUBE. If the tube is seal welded to the tubesheet then the weld material at the near tube end will need to be removed by lightly reaming with a tapered reamer.
2 PAGE 2 OF 11 FIGURE 2. Simplified View of a Straight Tube Heat Exchanger FAR END NEAR END TUBESHEET THICKNESS TUBESHEET TO TUBESHEET LENGTH CHANNEL HEAD LENGTH 3. Tubesheet-to-tubesheet length. What is the distance from the outer face of the near tubesheet to the outer face of the far tubesheet? 4. Tubesheet Thickness. What is the thickness of the far end tubesheet? 5. Heat Exchanger Channel. Is there a channel head present at the near end? If so, what is the length of the channel head? 6. Existing Obstructions Are there any obstructions (division plates, stud bolts, limited clearance overhead, etc.) that may interfere with any of the Pop-A-Plug System equipment? Do any of the obstructions require that the Pull Rod and Tube sections be a specific length? LIMITATIONS OF THIS TECHNIQUE While the Through-the-Tube plugging technique has proven to be both effective and reliable means for plugging tubes, several external factors can limit its success. These factors should be recognized and understood prior to starting. 1. Condition of the Tubes. The tubes to be plugged must be clean and free of any deposits. Deposits within the tubes can prevent the proper plug size from fitting through the tube to the far end of the heat exchanger. EST recommends hydroblasting and / or the use of aggressive tube cleaning brushes to clean the tubes. Some deposits may require chemical cleaning. Hard deposits that cannot be removed by hydroblasting, brushing, or chemical cleaning may require either drilling or rodding.
3 PAGE 3 OF Damaged Tubes. Tubes that are extremely bowed, bent, or have failed as a result of tube denting, implosion or other tube ID altering factor may not allow the plug to be passed through the tube to the far end. PRIOR TO PLUGGING 1. Clean the tube(s) thoroughly. 2. If the service of the heat exchanger permits, pierce the wall of the tube(s) in a location just beyond the tubesheet. The puncture should be cleanly through the tube wall. DETERMINING THE PROPER CPI / PERMA PLUG SIZE CPI / Perma Plugs and plug installation equipment will be selected based upon the tube ID. Actual tube measurements are best. Ideally the measurements should be taken at two locations, 90 degrees apart, at a point about 1 (25.4 mm) deep within the tube end. Further a number of tubes in both the inlet and outlet pass should be measured. If actual tube measurements are not available then the tube data (tube OD and wall thickness, or gage) may be obtained from the heat exchanger data sheet provided by the manufacturer. The tube data and the sizing guide shown in Appendix 1 may be used to determine the suggested CPI / Perma Plug size. Note: A careful evaluation of the repair history for the heat exchanger is also advised. If the tube bundle and/or tubes have been replaced, the actual tube size may vary considerably from the tube size indicated on the heat exchanger datasheet. CALCULATE INSTALLATION DEPTH FOR FAR END PLUG The CPI/Perma Plug must be installed into the tubesheet area of the tube only. EST recommends that the plug be positioned in the middle of the rolled area of the far end tube or the middle of the tubesheet if the tube is not rolled. To determine the proper Installation Depth subtract one half of the far end tube roll length from the tubesheet to tubesheet length. Refer to Figure 2. Example: Tubesheet face to tubesheet face = 10 ft. = 120 in. Far end tube roll length or Tubesheet thickness if unrolled = 4 Installation depth = [1/2 x 4 ] = 118 In this case the Installation Depth would be equal to 118 REQUIRED INSTALLATION EQUIPMENT CPI / Perma Plug installation hardware is dedicated to specific CPI / Perma Plug size(s) only. The following equipment is required: 1. A sufficient supply of CPI / Perma Plugs in the proper size and plug material. 2. Through-The-Tube Thread Adapter Kit(s) for the indicated plug size(s). Refer to the section titled Through-The-Tube Adapter Kit for more information on the Adapter Kits. 3. A Pop-A-Plug System Ram Package. Based on the plug size and material select either the Small Ram, Part Number PAP-6600, or Large Ram Package, Part Number PAP Note: V-1334 plug sizes and larger must be installed using the Large Ram. 4. Air Regulator Assembly, Part Number REG-TTT.
4 PAGE 4 OF A sufficient supply of Pull Rod and Tube Extensions to allow the CPI / Perma Plug to be positioned at the far end of the heat exchanger. 6. Additional Pop-A-Plug installation hardware is suggested as spares additional Plug Positioner for each CPI / Perma Plug size additional Channel Head Pull Rod Assembly (4 ft. or 6 ft.) 7. (2) small pipe wrenches (6 or smaller) or (2) pair of Vise Grips tape measure. ASSEMBLY OF HYDRAULIC EQUIPMENT: Installation of CPI / Perma Plugs at the far end of the heat exchanger requires that the Hydraulic Pump be operated to the installation pressure specified for the individual plug size and material. The pulling pressures will also vary by the hydraulic ram used during installation. Installation pressures are shown in either Table 1, for installations with the Small Ram, and Table 2, for installations with the Large Ram. Use of the Air Regular Assembly, Part Number REG-TTT, is mandatory. 1. Connect the Air Regulator assembly to the air input connection on the Hydraulic Pump, refer to Figure 3 below. 2. Connect the air supply to the Air Regulator input and set regulator to produce the proper hydraulic pressure by performing the following steps. a. Disconnect any items connected to the Hydraulic Pump output. b. Turn the Air Regulator adjustment knob fully counterclockwise. c. Depress the Hydraulic Pump pedal while viewing the pressure gauge. While keeping pump pedal depressed, slowly adjust the Air Regulator knob clockwise to activate the pump. Continue operating the pump until the proper hydraulic pressure required for the CPI / Perma plug size and material is achieved. Refer to Table 1 for plug installations using the Small Ram, or Table 2 for installations using the Large Ram. ADJUSTMENT KNOB ADJUSTMENT KNOB HYDRAULIC PUMP OUTPUT AIR INPUT PRESSURE GAUGE AIR REGULATOR ASSEMBLY PART NUMBER REG-TTT HYDRAULIC PUMP FIGURE 3. Air Regulator Assembly And Hydraulic Pump
5 PAGE 5 OF 11 d. Depress the release end of the Hydraulic Pump pedal to release the built-up pressure. Repressurize the Pump to verify that the proper hydraulic pressure has been set. Adjust Air Regulator as necessary. Release pressure. e. Connect one end of the hydraulic hose to the Pump output. The other end of the hose is to be connected to the Hydraulic Ram. Verify that all quick connects are fully tightened. The ram is now ready for use. THROUGH-THE-TUBE ADAPTER KIT The Through-The-Tube Adapter Kit includes a Through-The-Tube Adapter and a supply of Through-The-Tube Studs as shown in Figure 4. The Through-The-Tube (TTT) Adapter has a right hand male thread on one end and left-hand female thread on the other. The TTT Studs are threaded with both left and right hand threads. TTT Adapter Kits are plug size specific and are to be used in through-the-tube plugging applications in place of the breakaway supplied with the CPI / Perma Plugs. The applicable Adapter Kits for given plug sizes are shown in Tables 1 and 2. Adapter Kits should be installed as outlined in the following section. LEFT-HAND THREAD TO ENGAGE TTT ADAPTER STANDARD THREAD TO ENGAGE PLUG LEFT-HAND THREAD TO ENGAGE TTT STUD STANDARD THREAD TO ENGAGE PULL ROD REMOVE BREAKAWAY TTT STUD TTT LH ADAPTER FIGURE 4. Through-The-Tube Adapter Kit and CPI / Perma Plug PULL ROD ASSEMBLY FOR THROUGH THE TUBE PLUGGING, See Figure 5. The Pull Rod sections need to be assembled to achieve the desired length. The overall suggested length is approximately equal to the heat exchanger tubesheet to tubesheet length plus the length of the channel head (if applicable). NOTE: Pull Rod Extensions are shipped from the factory with the Pull Rods inside the Compression Tube. To speed the assembly process of the Pull Rod Extensions remove all Pull Rods from the mating Compression Tubes prior to continuing. The Pull Rods should be assembled on the ground to minimize bending. If space is limited, the Pull Rod Extensions can be assembled piece by piece in the heat exchanger tube to be plugged. 1. Remove breakaway from the CPI/Perma Plug to be installed through the tube. Note: Do not grip or in any way mar the surface of the tapered pin when unscrewing the breakaway. Discard the breakaway once removed. 2. Thread the right hand threaded end of the TTT Stud clockwise into the plug.
6 PAGE 6 OF Holding the plug thread it into the female left hand thread of the TTT Adapter until fully engaged. NOTE: Do not retighten after contact or plug / adapter kit assembly may unthread. The pulling stud will remain with the plug after installation. DO NOT USE A THREAD LOCKING AGENT. 4. Thread a TTT Adapter into the end of the first Extension Rod and tighten by hand. CPI/PERMA PLUG (NO BAW) TTT STUD TTT LH THREAD ADAPTER FIRST EXTENSION ROD PLUG POSITIONER FIRST COMPRESSION TUBE NEXT EXTENSION ROD NEXT COMPRESSION TUBE LOCK NUT CHANNEL HEAD ROD REMAINING TUBES KNURLED NUT ROD & TUBE POSITIONER STAND-OFF RING FIGURE 5. Pull Rod Assembly Set-up WARNING! DURING THESE INSTALLATION PROCEDURES CARE MUST BE EXERCISED SO THAT THE EXTENSION RODS DO NOT ROTATE DURING TIGHTENING OR LOOSENING OF OTHER CONNECTIONS. FAILURE TO HEED THIS WARNING MAY RESULT IN THE THRU-THE-TUBE ADAPTOR PREMATURELY DISENGAGING FROM THE PLUG. 5. Install the Plug Positioner, with arrow pointing toward plug, onto the first Extension Rod. The Plug Positioner should be installed so it rests against the plug. 6. Install the 6-inch long Tube, supplied as part of the Channel Head Assembly, onto the first Extension Rod so it is against the back of the Plug Positioner. 7. Thread the next Extension Rod onto the previous Extension Rod and firmly hand tighten. Keep both Rods straight to make certain that the joint is not subjected to bending while tightening. 8. Install the next Extension Tube over the Extension Rods. 9. Repeat steps 7 and 8 until the desired Extension length has been achieved. The desired length is approximately equal to the heat exchanger tubesheet to tubesheet length plus the length of the channel (if applicable). 10. The Channel Head Rod should be threaded onto the Extension Rods and firmly hand tighten. Keep both Rods straight to make certain that the joint is not subjected to bending while tightening. After tightening, verify that the joint cannot be loosened by hand. If it can, retighten. This is the last Rod section. 11. Install the remaining Tubes onto the Rod assembly. Remove slack from the Rod and Tube assembly by holding the last Tube and pulling on the Channel Head Rod.
7 PAGE 7 OF Set the Stand-Off Ring. A Stand-Off Ring is used to set the proper Installation Depth prior to installing the plug. The Stand-Off Ring locks onto an Extension Tube by tightening a thumb screw, refer to Figure 6. Make a measurement from the middle of the ring back along the Extensions for a distance equal to the Installation Depth. Using a file, mark the Extension at that point. The mark is permanent and will allow you to check that the Stand-Off Ring is in the proper position prior to each plug installation. Slide the Stand-Off Ring to the mark and firmly tighten the thumbscrew. CPI/PERMA PLUG RING INSTALLATION DEPTH STAND-OFF RING FIGURE 6. Setting Stand-Off Ring 13. Install the Rod & Tube Positioner onto the Rod assembly with arrow pointing toward the plug. 14. Thread the Knurled Nut onto the exposed threads of the Channel Head Rod to hold the assembly together during the next step. NOTE: Do not allow the rod to turn while threading on Knurled Nut as it could result in disengaging the TTT Adapter. 15. Plug should now be positioned for installation. When maneuvering the Pull Rod set-up make certain that it is adequately supported to avoid bending. Slide the set-up, plug end first, into the heat exchanger tube to be plugged until the standoff ring is against the tube end. Remove slack from the Rod and Tube assembly by holding the last Tube and pulling on the Channel Head Rod. 16. Remove the Knurled Nut from the Channel Head Rod without turning rod. 17. Slide the hydraulic Ram onto exposed Channel Head Rod. The Ram should be installed so the Ram piston strokes toward the operator. 18. Thread Knurled Nut onto the Channel Head Rod and firmly tighten against the Ram. Do not allow the rod to turn while threading on Knurled Nut as it could result in disengaging the TTT Adapter. 19. Install the Ram Safety Cable then the locknut onto the Pull Rod and hand tighten. Verify that the Stand-Off Ring is against the tube end. 20. While viewing the pressure gauge, press the Pump pedal to slowly pressurize the Ram. The Air Regulator, previously adjusted, will allow only the set pressure to build. If it appears that the proper installation pressure is going to be exceeded, STOP and readjust Regulator as specified above. Continue to operate the Pump until the Ram bottoms out or the previously set installation pressure is reached.
8 PAGE 8 OF 11 NOTE: When the Ram piston bottoms out the hydraulic pressure will reach the set pressure only because the piston is at the end of its travel. At this point it is still necessary to continue to step Release hydraulic pressure to allow the Ram to fully retract. Hold Ram handle while pulling on the Knurled Nut to remove any slack from the set-up. Thread Knurled Nut so it is against the Ram and firmly tighten. Do not allow rod to turn when tightening the Knurled Nut. 22. While viewing the pressure gauge, press the Pump pedal to slowly pressurize the Ram. Continue to operate the Pump until the Ram bottoms out or the proper installation pressure is reached. If the Ram bottoms out, repeat step 19. If the proper installation pressure has been reached and the Knurled Nut cannot be hand tightened by more than 1/4 of a turn after the hydraulic pressure is released, the plug has been properly installed. If the proper installation pressure has been reached and the Knurled Nut can be hand tightened more than 1/4 of a turn after the hydraulic pressure is released, repeat steps 19 and 20 until the Knurled Nut cannot be hand tightened by more than 1/4 of a turn after the hydraulic pressure is released. NOTE: Additional Adjustment of the Regulator may be necessary during this step. NOTE: Having to repeat steps 19 and 20, 4 to 5 times is not uncommon. 23. Released hydraulic pressure to allow the Ram to fully retract. 24. Remove the Knurled Nut and hydraulic Ram from the Rod. Do not allow the rod to turn while threading off the Knurled Nut. 25. Reinstall the Knurled Nut to ensure that no parts slip off of the Rod. Apply a light pulling force while turning the Rod clockwise to unthread the Pull Rod set-up from the installed plug. The Dual Thread Pulling Stud will remain with the installed plug. When disengaged withdraw the Pull Rod set-up from the tube. When maneuvering the Pull Rod set-up, make certain that it is adequately supported to avoid bending. QUESTIONS? Contact EST Group Customer Service at any of the following locations with questions. In USA and Canada: tel: , fax: , est-info@curtisswright.com In Europe: tel: , fax: ; est-emea@curtisswright.com In Asia: tel: , fax: , est-asia@curtisswright.com On the Internet: EST Group is a business unit of Curtiss-Wright Flow Control Company. EST Group provides a complete range of repair products, services and replacement parts covering the life cycle of tubular heat exchangers and condensers; additionally EST Group provides products and services to facilitate pressure testing pipe, piping systems, pressure vessels and their components. Visit EST Group on the Internet at
9 PAGE 9 OF 11 TABLE 1. Hydraulic Installation Pressures For Use With Small Ram Package (PAP-6600) Only. (See Table 2 for Large Ram) CPI / PERMA PLUG SIZE THROUGH-THE-TUBE ADAPTER KIT BRASS STAINLESS STEEL & CARBON STEEL BRASS SMALL RAM INSTALLATION PRESSURE (PSI) STAINLESS STEEL & CARBON STEEL.471 TTT-1032 TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT FIGURE 7. Small (White) Ram, Model PAP-6600
10 PAGE 10 OF 11 TABLE 2. Hydraulic Installation Pressures For Use With Large Ram Package (PAP-1750) Only. (See Table 1 for Small Ram) CPI / PERMA PLUG SIZE THROUGH-THE-TUBE ADAPTER KIT BRASS STAINLESS STEEL & CARBON STEEL BRASS LARGE RAM INSTALLATION PRESSURE (PSI) STAINLESS STEEL & CARBON STEEL.471 TTT-1032 TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT TTT-1220 N/A TTT-1220 N/A TTT-1220 N/A TTT-1220 N/A TTT-1220 N/A 4300 FIGURE 8. Large (Orange) Ram, Model PAP-1750
11 PAGE 11 OF 11 APPENDIX 1. Recommended CPI / Perma Plug Sizes For Use In Through-The-Tube Plugging Applications Only WALL THICKNESS TUBE OD BWG DECIMAL 5/8" 3/4" 7/8' 1" 1-1/4" UNROLLED ID ROLLED ID PLUG PART # N/A V-471 V-584 V-712 V UNROLLED ID ROLLED ID PLUG PART # N/A V-491 V-621 V-735 V UNROLLED ID ROLLED ID PLUG PART # N/A V-512 V-621 V-735 V UNROLLED ID ROLLED ID PLUG PART # N/A V-524 V-649 V-774 V UNROLLED ID ROLLED ID PLUG PART # N/A V-555 V-670 V-804 V UNROLLED ID ROLLED ID PLUG PART # V-471 V-584 V-712 V-837 V UNROLLED ID ROLLED ID PLUG PART # V-471 V-584 V-712 V-837 V UNROLLED ID ROLLED ID PLUG PART # V-491 V-621 V-735 V-853 V UNROLLED ID ROLLED ID PLUG PART # V-512 V-621 V-735 V-853 V UNROLLED ID ROLLED ID PLUG PART # V-524 V-649 V-774 V-853 V UNROLLED ID ROLLED ID PLUG PART # V-524 V-649 V-774 V-853 V UNROLLED ID ROLLED ID PLUG PART # V-524 V-670 V-774 V-919 V UNROLLED ID ROLLED ID PLUG PART # V-524 V-670 V-774 V-919 V UNROLLED ID ROLLED ID PLUG PART # V-555 V-670 V-804 V-919 V UNROLLED ID ROLLED ID PLUG PART # V-555 V-670 V-804 V-919 V-1171 NOTE: Plug Part Numbers above do not include material designation. For recommended sizes in near end applications refer to CPI / Perma Plug rolled tube sizing chart shown in (DC1221).
THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS
PAGE 1 OF 13 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS CPI / Perma Plugs are part of the Pop-A-Plug Tube Plugging System. Unlike other tube plug designs, and under the proper conditions, CPI / Perma
More informationEXPANSION SEAL TECHNOLOGIES DC /02 PAGE 1 OF 1 THROUGH-THE-TUBE PLUGGING TECH TIP
EXPANSION SEAL TECHNOLOGIES DC8043 12/02 PAGE 1 OF 1 THROUGH-THE-TUBE PLUGGING TECH TIP When performing Through-the-tube (TTT) Plugging, the installation load from the hydraulic ram causes the pull rod
More informationEST Group DC /97 REV 15 12/17 Page 1 of 6
EST Group DC1220 02/97 REV 15 12/17 Page 1 of 6 Procedure for Pop-A-Plug CPI/Perma Near End Installation Curtiss Wright Proprietary This document is the property of and contains information proprietary
More informationVibra-Proof Condenser Plugs. The Condenser Plugs That Won t Vibrate Loose.
Vibra-Proof Condenser Plugs The Condenser Plugs That Won t Vibrate Loose. Vibra Proof Condenser Plugs CPI Plugs Perma Plugs P2 High Pressure Plugs Ram Packages Tube Stabilizers Manual Installation Tools
More informationEST GROUP DC /05 REV4 05/09 PAGE 1 OF 6 OPERATING PROCEDURES FOR DOUBLE BLOCK AND BLEED PLUGS - INTERNATIONAL
PAGE 1 OF 6 OPERATING PROCEDURES FOR DOUBLE BLOCK AND BLEED PLUGS - INTERNATIONAL WARNING! PRESSURE TESTING IS INHERENTLY DANGEROUS. STRICT ADHERENCE TO THESE OPERATING INSTRUCTIONS AND INDUSTRY SAFETY
More informationOperating Procedures for Test Plug Lifting Fixture
EST Group DC2590 04/14 Page 1 of 8 Operating Procedures for Test Plug Lifting Fixture WARNING The Test Plug Lifting Fixture is designed for use with 10 thru 24 (DN250 DN600) GripTight Test Plugs, as well
More informationHeat Exchanger Tube Plugging & Testing Equipment. EST Group
EST Group Heat Exchanger Tube Plugging & Testing Equipment Pop-A-Plug Tube Plugs Installation & Removal Equipment Pop-A-Plug Tube Stabilizers G-Series Tube Testing Tools EST GROUP Established in 1968 and
More informationHeat Exchanger Tube Plugging and Testing Equipment. EST Group
EST Group www.cw-estgroup.com Heat Exchanger Tube Plugging and Testing Equipment Pop-A-Plug Tube Plugs Installation & Removal Equipment Pop-A-Plug Tube Stabilizers G-Series Tube Testing Tools EST GROUP
More informationMGM Brakes Service Manual
MGM Brakes Service Manual For: S-Cam Piston Type Service and Spring Brake Chambers Form No. 5009 Issued 6/91 - Revised 4/2010 MODEL MB-T SERIES MODEL MG-T SERIES Superseded by the MJS SERIES Form #5044
More informationHigh Lift Flange Weld/Test Plug (3/4"-8") - Technical Specifications
EXPANSION SEAL TECHNOLOGIES DC8055 11/98 REV 4 03/05 High Lift Flange Weld/Test Plug (3/4"-8") - Technical Specifications Flange Size Ansi Flange Class Pipe Schedule Part Number Plug OD Seal to Pipe Pipe
More informationEXPANSION SEAL TECHNOLOGIES DC /01 REV 2 06/05 PAGE 1 OF 4
EXPANSION SEAL TECHNOLOGIES DC9567 11/01 REV 2 06/05 PAGE 1 OF 4 OPERATING PROCEDURES FOR GRIPTIGHT HIGH PRESSURE TEST PLUGS WITH ALTERNATE SEAL MATERIALS Description: GripTight plugs supplied with alternate
More informationOPERATING PROCEDURES FOR G-160 TUBE TESTING TOOLS
Page 1 of 9 OPERATING PROCEDURES FOR G-160 TUBE TESTING TOOLS Curtiss Wright Proprietary This document is the property of and contains information proprietary to Curtiss Wright and/or its subcontractors
More informationEXPANSION SEAL TECHNOLOGIES DC /01 REV 2 06/05 PAGE 1 OF 4
EXPANSION SEAL TECHNOLOGIES DC9567 11/01 REV 2 06/05 PAGE 1 OF 4 OPERATING PROCEDURES FOR GRIPTIGHT HIGH PRESSURE TEST PLUGS WITH ALTERNATE SEAL MATERIALS Description: GripTight plugs supplied with alternate
More informationBolt Type Test Plug - Technical Specifications
EXPANSION SEAL TECHNOLOGIES DC8048 05/98 REV 2 12/04 Bolt Type Test Plug - Technical Specifications Tube ID Shaft Shaft Shaft/Port "A" LI L2 L3 Max. Op. Shaft Hex Hex Nut Approximate Range OD Quantities
More informationINSTRUCTION MANUAL IM-422 For HTC/COUPLING ASSEMBLY HC-8088
No Revision 2/22/18 INSTRUCTION MANUAL IM-422 HTC/COUPLING ASSEMBLY The Riverhawk Company reserves the right to make changes updating this document without dissemination or notice. The latest revision
More informationMUELLER GAS. No-Blo Valve. Changers. Reliable Connections. General Information 2-3. Plugging Unit Assembly 4-5. Removing Old Valve 5-6
operating Instructions manual MUELLER GAS TAble of contents PAGE No-Blo Valve General Information 2-3 Plugging Unit Assembly 4-5 Removing Old Valve 5-6 Installing New Valve 6-7 Changers! WARNING: 1. Read
More informationOPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP
PAGE 1 OF 10 OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP EFFICIENT, EASY OPERATION Air operated pump Wide range of pressures and volumes Easy to operate controls Output pressure
More informationUNIFLO Control Valve
Severe Service Control Valves MAINTENANCE AND INSTRUCTION MANUAL UNIFLO Control Valve The Problem Solver TM BOTTOM COVER DESIGN DFT INC. 2 www.dft-valves.com DFT INC. 3 www.dft-valves.com WARNING: USER
More informationINSTRUCTION MANUAL IM 379 For Gas Turbine Tensioned Studs and Nuts CUSTOMER'S INFORMATION BOX CONTENTS ARE INDEPENDENT OF RIVERHAWK DOCUMENT CONTROL
INSTRUCTION MANUAL IM379 For Gas Turbine Tensioned Studs and Nuts Applicable Bolting Connections 7HA.02 Gas Turbine to GENH65 Generator 7HA.02 Gas Turbine to GENH84 Generator 7HA.02 Gas Turbine to H53
More informationMGM Brakes Service Manual
MGM Brakes Service Manual MAGNUM Performance Plus Spring Brake Actuators (MJ-Series 3.00 / 76mm Long Stroke ) For: S-Cam Tamper-Resistant MAGNUM Performance Plus Spring Brake Actuators Figure 1 A B C Your
More informationHydraulic Transmission Jack, Telescopic
Operating Instructions & Parts Manual Hydraulic Transmission Jack, Telescopic Model 4000 400 (Air Operated) Capacity 000 lbs. 000 lbs. Model 4000 Model 400 U.S. Patent No. 6,02,377! This is the safety
More informationM-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components
Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options
More informationANDCO Eagle Actuator Instruction Manual
ANDCO Actuators ANDCO Eagle Actuator Instruction Manual The information contained in this manual is essential to safe, successful, long term operation of your Andco Eagle Linear Actuator. Read and follow
More informationStay-IN-Play with Panic Stop Braking
INSTALLATION INSTRUCTIONS TOWED VEHICLE BRAKING SYSTEM Stay-IN-Play with Panic Stop Braking SMI Manufacturing, Inc. P.O. Box 14040 Evansville, IN 47728 1-800-893-3763 www.smibrake.com SIP0906 Model SIP0603
More informationInstallation Instructions Table of Contents
Installation Instructions Table of Contents Pre- Installation of Garage Storage Lift 2 Layout the Garage Storage Lift 3 Installing the strut Channels 3 Install the Drive Assembly 5 Install the Drive Shaft
More informationVALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X
ASSEMBLY MANUAL Keep With Operator s Manual VALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X TRACTOR AND VALVE KIT GENERAL
More informationDISC BRAKE/DUAL MASTER CYLINDER CONVERSION. Tools, Equipment and Supplies Needed:
Please take the time to read the enclosed instructions carefully. If you have any questions, call our Product Assistance personnel for clarification. It is important to note that these instructions contain
More informationValtek Auxiliary Handwheels and Limit Stops
Valtek Auxiliary s and Limit Stops Table of Contents Page 1 General information 2 Installation 2 Side-mounted handwheels, size 25 and 50 (linear actuators) 3 Side-mounted handwheels, size 100 and 200 (linear
More informationSpring Return and Double Acting Pneumatic Quarter-turn Actuators Operations Manual
Spring Return and Double Acting Pneumatic Quarter-turn Actuators Operations Manual Table of Contents General..................... 1 Pneumatic Recommendations... 1 Construction................. 2 Disassembly
More informationSERVICE INSTRUCTIONS D TON
1120 SOUTH CRYSTAL AVE * BENTON HARBOR MI PH: 269-925-7777 FAX: 269-925-6656 SERVICE INSTRUCTIONS D-51223 4 TON TO ASSEMBLE: 1. Check the handle set screw for tightness. CUSTOMER PRE-USE INSTRUCTIONS THE
More informationDethatcher Kit Greensmaster 3000 Series
Form No. 338 944 Dethatcher Kit Greensmaster 3000 Series Model No. 04493 Serial No. 3000000 and Up Operator s Manual English (EN) Contents Page Specifications............................... General Specifications.....................
More informationInstruction Manual for HSPA Take-Up Units
Installation Instruction Manual for HSPA Take-Up Units Warning: To ensure the drive is not unexpectedly started, turn off and lockout the power source before proceeding. Failure to observe these precautions
More informationMGM Brakes Service Manual
MGM Brakes Service Manual MODEL LTR-T - 2.50 Pre 6/1/98 MODEL LTR-T - 2.50 Post 5/31/98 MODEL LTR-L3-3.00 For: Long Life Integral Release Bolt Double Diaphragm Spring Brakes Several design improvements
More informationINSTRUCTION MANUAL 16K - Fifth Wheel Hitch
You can take it with you. INSTRUCTION MANUAL 16K - Fifth Wheel Hitch Product No. 30047 DEALER/INSTALLER: END USER: (1) Provide this Manual to end user. (2) Physically demonstrate hitching and unhitching
More informationTransmission Overhaul Procedures-Bench Service
How to Assemble the Lower Reverse Idler Gear Assembly Special Instructions In 1996 Eaton changed the reverse idler system design. In the nut design, the reverse idler bearing was lubricated through a hole
More informationTemperature Sensor Series
GENERAL DESCRIPTION The patented* No. 85026-Series Temperature Sensor contains a two-position valve operated by temperature variations around the integral sensing bulb. It is used to vent or block a pneumatic
More informationINSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool
INSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool INSTALLATION INSTRUCTIONS FOR THE MODEL MM-30 & MODEL MM-50
More informationHeavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems
Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems Instruction Sheet 408-8039 02 JUN 16 Rev G Ram Post Wire Disc Insulation Disc Insulation Crimper Stripper
More information1989 Jeep Cherokee. STEERING COLUMN' '1989 STEERING Jeep Steering Columns STEERING COLUMN STEERING Jeep Steering Columns
STEERING COLUMN 1989 STEERING Jeep Steering Columns DESCRIPTION All models use collapsible steering columns. All columns have integral ignition switch and locking device. Optional tilt wheel is available
More informationInstallation Guidelines
STYLE No. EAXS32 EAXS33 EAXS34 EAXS35 STYLE No. EAHS32 - sold separately EAHS33 - sold separately EAHS34 - sold separately EAHS35 - sold separately 19 1 /4" 8" 9" 9" 3" In the State of Massachusetts, all
More informationTube Plugs.
Tube Plugs www.elliott-tool.com Tube Plugs Table of Contents Page Tube Plugs Aluminum Siphons Boilers-Firetube Boilers-Watertube Sugar Mill Vacuum Pans Surface Condensers Chillers & Heat Exchangers Feedwater
More informationWARNING. BX Dodge Durango Jeep Grand Cherokee (All Models)
(Includes Trail Rated & Adaptive Cruise Control) Please read BOTH these and the General Instructions prior to installing or operating this equipment. 1. Blue Ox towing products and accessories are intended
More informationInstallation Instructions
Installation Instructions Product: SwitchBlade Swaybar System Part Number: PN 9100 Application: Jeep Wrangler TJ, 1997-06 (front) Welcome CONGRATULATIONS on purchasing a SwitchBlade Swaybar System from
More informationTools, Equipment and Supplies Needed:
153-162 DISC BRAKE/DUAL MASTER CYLINDER CONVERSION Please take the time to read the enclosed instructions carefully. If you have any questions, call our Product Assistance personnel for clarifi cation.
More informationFluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL
Fluid-O-Tech PUMP TECHNOLOGY AT ITS BEST WWW.FLUID-O-TECH.COM Office: 161 Atwater St., Plantsville, CT 06479 Phone: (860) 276-9270 Fax: (860) 620-0193 ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL 08/09 Ed.,
More informationManifold Isolation Valves
300 N. Opdyke Rd. Introduction The Stainless Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options
More informationINSTRUCTION MANUAL IM 406 For Gas Turbine Tensioned Studs and Nuts CUSTOMER'S INFORMATION BOX CONTENTS ARE INDEPENDENT OF RIVERHAWK DOCUMENT CONTROL
INSTRUCTION MANUAL IM 406 For Gas Turbine Tensioned Studs and Nuts Applicable Bolting Connections Frame 6FA Gas Turbine to 6FA Generator Load Gear to 6FA Generator Frame 6F.01 Gas Turbine to Generator
More informationM Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components
Page 1 Introduction The M-8200 Precision Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options with
More informationAir Actuated Hydraulic Bottle Jacks
Air Actuated Hydraulic Bottle Jacks Operating Instructions & Parts Manual Model Number Atd-7412 Atd-7420 Capacity 12 Ton 20 Ton Atd Tools Inc. 160 Enterprise Drive, Wentzville MO 63385 Printed in China
More informationHeavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems
Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems Instruction Sheet 408-8040 30 NOV 17 Rev H Ram Assembly Ram Post Locking Screw Stock Drag Drag Release
More informationThe steering column is of a modular construction and features easy to service electrical switches.
file://c:\tso\tsocache\vdtom_5368\svk~us~en~file=svkb4a01.htm~gen~ref.htm Page 1 of 3 Section 11-04A: Steering Column, Ranger DESCRIPTION AND OPERATION 1997 Ranger Workshop Manual Steering Column NOTE:
More informationUSER MANUAL. LP Unit 5000 PSI. HP Unit 7500 ALL - IN - ONE ALL - IN - ONE ALL - IN - ONE. 4" Drive Handles. LP Units Available in 12" Insertion Length
LP Unit 5000 PSI Flow Innovations MADE IN USA USER HP Unit 7500 PSI MANUAL Flow Innovations MADE IN USA ATOMIZER ATOMIZER COUPON HOLDER 4" Drive Handles COUPON HOLDER INJECTION QUILL INJECTION QUILL LP
More informationSPECIFICATIONS CONTENTS: Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting
Model 3322 22 Ton Air/Hydraulic Truck Axle Jack OWNER'S MANUAL CONTENTS: Page 1 Page 2 Page 3-4 Page 4-5 Page 5 Page 6 Page 7 Page 8 Specifications Warning Information Assembly Operating Instructions Preventative
More informationONYX VALVE CO MODEL DAO-PFC Installation & Maintenance
ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFC pinch valve is an open frame valve without housing enclosure and fails closed on loss of air. The actuator drives
More informationGM Floor Mount Automatic Transmission Shifter Installation Instructions
GM Mount Automatic Transmission Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com GM Mount Automatic Transmission
More informationFisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations
Instruction Manual 1061 H & J Actuator Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...
More informationDISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control
Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control BRADLEY SC A S53-141 4" Centerset S53-148 4" Centerset, no Solenoid Valve S53-186 4" Centerset with 8" Trim Plate S53-285 Centershank
More informationGenesis Double Adjustable Shock Assembly and Repair
Genesis Double Adjustable Shock Assembly and Repair General Operating Description The Genesis Adjustable Shock is adjusted by moving one or both of two bypassing sliding valves. These valves slide longitudinally
More informationOperation and Maintenance Manual http://www.torsionx.eu Use the MaxDrv Series Square Drive Torque Wrench Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 to install and remove threaded fasteners requiring precise
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS REAR DISC BRAKE CONVERSION KIT A158 1994-97 Dodge Ram 1500 (2WD & 4WD) and REAR DISC BRAKE CONVERSION KIT A158-1 1998-01 Dodge Ram 1500 (2WD & 4WD) Thank you for choosing STAINLESS
More information<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W
B&W Trailer Hitches 6 Hawaii Rd / PO Box 86 Humboldt, KS 66748 P:60.473664 F:60.869.903 Turnoverball Gooseneck Hitch Installation Instructions MODEL 08
More informationGBP784B INSTALLATION TOOL
GBP784B INSTALLATION TOOL GAGE BILT MADE IN U.S.A. GAGE BILT PRODUCTS CORP. 14500 Barber Drive (586) 771-7664 Warren, Mi 48088 (586) 771-2665 Fax e-mail:solutions@gagebilt.com / www.gagebilt.com TABLE
More informationOWNER S TECHNICAL MANUAL
OWNER S TECHNICAL MANUAL 2.5kg Grease Kit 6336 Description The Champion 6336 2.5kg grease kit is a manually operated, spring powered grease kit that comes complete with a hand piece. It is designed to
More informationOWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit
OWNER S TECHNICAL MANUAL 6336N 2.5kg Grease Kit 6336N Description The 6336N 2.5kg grease kit is a manually operated, spring powered grease kit with ergonomic, user friendly rod cap that comes complete
More informationBOLT TENSIONERS. carefully before use and retain it for reference.
BOLT TENSIONERS This manual contains IMPORTANT WARNINGS, CAUTIONS and other instructions. Read and understand the instructions manual carefully before use and retain it for reference. TORCUP MIDDLE EAST
More informationOperating Procedures for 4 to 24 GripTight Isolation Plugs
EST Group DC2690 06/12 REV 5 05/17 Page 1 of 15 Operating Procedures for 4 to 24 GripTight Isolation Plugs WARNING Pressure testing is inherently dangerous. Strict adherence to these Operating Procedures
More informationRekluse Motor Sports. The ProStart Clutch. H-D Big Twin ( )
Rekluse Motor Sports The ProStart Clutch H-D Big Twin (1990 1997) Installation Guide Copyright 2006 Rekluse Motor Sports ProStart Revision 1.000 RMS680 H-D Big Twin 195-680 Manual Revision: 121206 Rekluse
More informationONYX VALVE CO MODEL DAO-ADA Installation & Maintenance
ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-ADA pinch valve is an open frame valve without housing enclosure and fails last position on loss of air. This actuator
More informationOperating Procedures for GripTight High Pressure Test Plug
Page 1 of 13 Operating Procedures for GripTight High Pressure Test Plug Curtiss Wright Proprietary This document is the property of and contains information proprietary to Curtiss Wright and/or its subcontractors
More informationChrysler 727, 904, 518 Floor Mount Automatic Transmission Shifter Installation Instructions
Chrysler 727, 904, 518 Mount Automatic Transmission Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Release Button
More informationTooling Assistance Center
Safeguards are designed into this application equipment to protect operators and maintenance personnel from most hazards during equipment operation. However, certain safety precautions must be taken by
More informationw w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required
-J006 REV. 006-08- CRUISE CONTROL KIT GENERAL Kit Number 7796-07 Models For the most up-to-date model fitment information, please see the product label or www.harley-davidson.com. Additional Parts Required.
More informationINSTALLATION INSTRUCTIONS
Product: Switchblade Swaybar System Part Number: JKS9100 INSTALLATION INSTRUCTIONS Applications: Wrangler TJ, 1997-06 (front) 517-278-1226 tech@jksmfg.com www.jksmfg.com 491 W. Garfield Avenue, Coldwater,
More informationONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance
ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx series CAR-PFO and CAP-PFO pinch valves fail open on loss of air. The simple spring and air bag arrangement drives
More informationIBT Series Square Drive Torque Wrenches
IBT Series Square Drive Torque Wrenches Operation and Maintenance Manual Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 http://www.torsionx.com Use the IBT Series Square Drive Torque Wrenches Model.75, 1, 3,
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS REAR CONVERSION KIT A111-2 (FORD 8" & 9" SMALL BEARING) & REAR CONVERSION KIT A111-3 (FORD 9 TORINO) Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking
More informationEZ LINER EXPRESS USERS MANUAL
EZ LINER EXPRESS 2013 Vehicle Service Group CHIEF'S LIMITED ONE-YEAR WARRANTY & LIABILITY Chief Automotive Technologies warrants for one year from date of installation and/or purchase any components of
More informationTHIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908
DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS
More informationShaver Industries. Assembly Instructions Spring Assist Vertical Vinyl Curtain Door Projection Mount
Shaver Industries 20 Steckle Place, Kitchener, ON N2E 2C3 Ph 1(888) 766 8328 www.shaverinc.com Assembly Instructions Spring Assist Vertical Vinyl Curtain Door Projection Mount Valued Shaver Customer: We
More informationInstructions for INSTALLATION -- OPERATION -- MAINTENANCE of the SELAS AIR/GAS BLENDER VALVE. (for PROPANE/AIR, BUTANE/AIR AND OTHER BLENDS)
DESCRIPTION The SELAS Blender Valve is a three-port, adjustable area valve which accurately mixes any two of a wide variety of gases. Air and Gas ports in a movable piston are matched to complimentary
More informationOperation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded
More informationFord C4 and C6 Floor Mount Automatic Transmission Shifter Installation Instructions
Ford C4 and C6 Mount Automatic Transmission Shifter Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 tech@lokar.com www.lokar.com Ford C4 and C6 Mount
More informationInsta-Valve 250 Patriot TM
Insta-Valve 250 Patriot TM 4-12 Nominal Size Installation Instructions for use with the Hydra-Core Pipewall Sampling Kit IV250MAN 4-12 IV 250 PWSK v1.93 Revised 07/11/2018 Covered by United States Patent
More informationPowerglide Automatic Floor Mount Shifter Installation Instructions
Powerglide Automatic Mount Installation Instructions Building American Quality With A Lifetime Warranty! TOLL FREE 1-877-469-7440 (865) 966-2269 FAX (865) 671-1999 tech@lokar.com www.lokar.com Powerglide
More informationSUPER TUBE-TUGGER Continuous Tube Extractor For 1-1/2 2 Tube OD ( )
www.elliott-tool.com TM-42 Rev. 9/20/04 Elliott offers a complete line of precision tube tools, including: tube expanders Boiler Expanders Heat Exchanger Expanders Condenser Expanders Refinery Expanders
More informationMICRO WELD MODEL DP1 & DP2 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL
MICRO WELD MODEL DP1 & DP2 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL 1 TABLE OF CONTENTS 1.0 SPECIFICATIONS 2.0 GENERAL OPERATING INSTRUCTIONS 3.0 BASIC OPERATING PARTS
More informationAmTryke Adult Recumbent Model HP1000 #50-HC-1000
AmTryke Adult Recumbent Model HP1000 #50-HC-1000 TOOLS Needed for Assembly 5 mm Allen Wrench 8 mm Socket or Wrench 10 mm Socket or Wrench 14 mm Socket or Wrench 15 mm Socket or Wrench 22 mm Socket or Adjustable
More informationAUTO REWIND AIR HOSE REEL
Model #s 46845, 46848 AUTO REWIND AIR HOSE REEL OPERATOR S MANUAL STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!? NEED HELP? Save time, contact us first. 888-648-8665 support@tekton.com WARNING:
More informationOWNER S MANUAL PRODUCT CODE: 2006T
Jul-18 Product Code: 2006T OWNER S MANUAL PRODUCT CODE: 2006T HYDRAULIC PIPE BENDER 12,000KG Model Capacity Bending Die No of Attachments 12,000kg 1/2", 3/4", 1", 1-1/4", 1-1/2", 2" 6 Made in China to
More informationHexPro Series Low Profile Wrenches
HexPro Series Low Profile Wrenches Operation and Maintenance Manual Model 2HP 4HP 8HP 14HP 30HP www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install
More informationSERVICE MANUAL L130B / L4130 Series Logstacker Drive Axle With Bolt-On Stub End Retainer
SERVICE MANUAL L130B / L4130 Series Logstacker Drive Axle With Bolt-On Stub End Retainer Page 1 Allied Form #80-930 Rev 07/2009 SERVICE MANUAL LOG STACKER DA202 DRIVE AXLE TABLE OF CONTENTS PROCEDURE FOR
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Automatic Insertion Heated Regulator High Voltage Model IHRA-4SS-220/230 100 or more inch insertion length The information in this manual has been
More informationPREPOINT CHAMFER GRINDER MODEL Section 1. Set up and operation
PREPOINT CHAMFER GRINDER MODEL 6-94 Set up and operation Section 1 1. Installation of the proper size collet. This machine used a 5-C style collet. This can be changed by loosening of he set screw located
More informationIDEAL Stripmaster Model 950 Wire Stripper #45-950
IDEAL Stripmaster Model 950 Wire Stripper #45-950 IDEAL Stripmaster Model 950 Wire Stripper Introduction The IDEAL Stripmaster Model 950 Wire Stripper is an electrically operated, pneumatic precision production
More informationVertical Vinyl Curtain Door
Vertical Vinyl Curtain Door Face Mount Installation Instructions System Overview: Your Aleco Vinyl Vertical Curtain Door is a high quality, high performance flexible door system based on proven components
More informationSD Bendix Manual Slack Adjusters DESCRIPTION ADJUSTING MECHANISM OPERATION
SD-05-1200 Bendix Manual Slack Adjusters WORM SHAFT (LOCK SCREW) FIGURE 1 - POSITIVE LOCK TYPE SLACK ADJUSTER DESCRIPTION In an s-cam type foundation brake, the final link between the pneumatic system
More informationLong Chassis Hydraulic Service Jacks
Long Chassis Hydraulic Service Jacks Operating Instructions & Parts Manual Model Number Atd-7390 Atd-7391 Capacity 5 Ton 10 Ton Atd Tools Inc. 160 Enterprise Drive, Wentzville MO 63385 Printed in China
More informationService Bulletin Trucks Date Number Page
Mack Trucks, Inc. Allentown, PA USA (Also applies to Mack Trucks Australia, Operation and Adjustment Only, CXX, CLX, CMH, CMM and CSM Models) (Supersedes SB313005 dated 03/24/08) Service Bulletin Trucks
More informationASSEMBLY INSTRUCTION MANUAL
ASSEMBLY INSTRUCTION MANUAL 500, 600, 660, 5010, 6010 & 6610 Snowblower Electric Spout Rotation Kit Instructions 122013 P4710 Electric spout rotation kit is to be used in place of a hydraulic or hand
More informationService Jacks. Operating Instructions & Parts Manual. Model Number. Capacity 4 Ton 4 Ton Air/ Manual 10 Ton 10 Ton Air/ Manual HW93657/ HW93660
Service Jacks Operating Instructions & Parts Manual Model Number HW93657 HW93667 HW93660 HW93662 Capacity 4 Ton 4 Ton Air/ Manual 10 Ton 10 Ton Air/ Manual Made in North America HW93657/ HW93660 HW93667/
More information