VERIS FLOW MEASUREMENT GROUP
|
|
- Candice Ray
- 6 years ago
- Views:
Transcription
1 1 VERIS FLOW MEASUREMENT GROUP
2 Flow Meter Considerations 1. Pipe Size 2. Media Being Measured 3. Flow Rates 4. Pressure 5. Temperature 6. Outputs? 2
3 3 Flowmeter Sizing
4 4 Application Data Sheets
5 How Verabar Works Flo w Hi + - Pressure Low Pressure Low Pressure Vortices Average Velocity Flow DP High Pressure Verabar's superior performance is due to its shape, surface roughness, and low pressure port location Verabar senses and averages the natural pressures created by the velocity profile 5
6 Verabar Outperforms Other Insert Meters Velocity profiles vary with upstream pipe configuration and disturbances. Verabar ±1% Other Textbook Profile Actual Profiles ±10% Location of Average Velocity The Verabar averages the profile. Other insert meters only sense a single point. 6
7 Bullet Shape Sensor Generates Accurate & Trouble-Free Performance No clogging Stable signal Low drag and increased structural strength Solid one-piece construction Vortices Frontal surface roughness lowers drag and extends accuracy range Pressure ports are forward of separation point to eliminate clogging and produce stable signal 7
8 Verabar's Non-Clog Design Low-pressure ports located on sensor sides virtually eliminate clogging and produce an extremely stable signal 8
9 Advantages of Frontal Surface Roughness Turbulent Boundary Layer: Lowers drag and vortex- shedding forces by 50% Predictable, constant drag coefficient Dormant/Laminar Boundary Layer: Increases drag and vortex-shedding forces Unpredictable drag coefficient Verabar's Roughened Surface Competitors Smooth Surface Wake Separation point Verabar's relative lowpressure sensing port location Wake Relative low - pressure port locations Variable separation point 9
10 Verabar's No-Leak Construction Verabar Flow Sensor Solid, one-piece construction No leaks between chambers Verabar Competitors' Construction Tubes within a tube can leak due to vibration or changes in pressure or temperature Round, Diamond and T Shapes L H L H L H L 10
11 Exclusive Benefits of Verabar Flow Sensor Improved accuracy and turndown Eliminates clogging of sensor ports Superior signal stability Lowers drag, flow-induced vibration 5-year performance warranty Up to 2500 LB ANSI, 6000 PSI and 1000 Deg F Square and Rectangular Ducts, Large Stacks feet in length 11
12 12 22 FOOT VERABAR (V510)
13 The Verabar DP Advantage DP is one of the most reliable, dependable flow measurement systems Plant personnel can verify calibration and service transmitters in the field Measures gas, liquid and steam Insertion and retraction under pressure, remote mount Low permanent pressure loss Minimum pipe penetrations Lower installation cost 13
14 Verabar Models Regular Spring-Lock Retractable Hot Taps Regular V200 Flanged V400 Regular Spring- Lock V500 V100 V150 V550 General Purpose Flanged V510 V110 14
15 Verabar Retractable (Hot Tap) Models Insert and Retract Under Full Pipe Pressure Models Threaded Flanged Models Synchro-Drive Fast Insertion Of Dual-Rod Drive Systems Drive Nut Drive Chain Protective Chain Shroud 15
16 Straight-Run Requirements 24D 18D Two Or More Elbows In Different Planes 9D 7D All Valves Eccentric Reducers & Expanders One Or More Tees, Y s Or Crosses, Single Inlet, Multiple Outlets (Same Or Different Plane) < 5D Two Or More Elbows In < 5D Same Plane Open Gate, Ball Or Plug Valve One Or More Tees, Y s Or Crosses, Single Inlet, Multiple Outlets (Same Plane) > 5D D Concentric Reducers & Expanders 2D 3D Elbow Mount For Minimum Straight Run (Accuracy ±3.0% & Requires An Adjusted K Factor) Sensors Must Be Located In Plane With The Center Line Of The Elbow 16
17 Installation and Orientation Simple, fast installation Accomplished by plant personnel Horizontal Pipes 360 Vertical Pipes 160 Gas 160 Liquid or Steam Remote Mount Gas Direct Mount Liquid or Steam 17
18 Some of exotic materials we ve used: Exotic Materials Hastelloy C Haynes 25 (2100 Deg. F, cobalt-nickel-chromium-tungsten alloy) Tantelum Infused (Hydrogen Bromine, Sulf. Acid) Monel Duplex SS (2x stronger than regular SS) Inconel Kynar (PVDF - Polyvinylidene fluoride) Nickel Aluminum Bronze (sea water) 310 SS 316 H (High Temp SS rated for over 1000 Deg.) 18
19 Verabar Summary Features & Benefits Gas, Liquid, Steam DP is a well known technology ±1% of rate accuracy Excellent Repeatability (± 0.05%) Stable signal & no clogging Solid Steel Construction-No Leaking Hot tap installation Low permanent pressure loss 5 Year Warranty Maintenance Free Bullet Shape Roughened Surface Wake Separation Point 19
20 20 Veris Accelabar
21 ACCELABAR DESIGN The INLET is a patented torroidal radius that accelerates and conditions the flow to produce a linear velocity profile The STRAIGHTENING & SETTLING ZONE stabilizes & linearizes the velocity profile The DIFFUSER is a gradual increase in the diameter to reduce the permanent pressure loss 21
22 22 ACCELABAR ADVANTAGES
23 23 ACCELABAR ADVANTAGES
24 24 ACCELABAR ADVANTAGES
25 Integral Expanders and Reducers Saves on Installation Cost 12 x 10 Reducers 8 x 12 Expanders 25
26 Single Source Responsibility 5 year guarantee from date of invoice 3 VALVE MANIFOLD D/P or MV TRANSMITTER RTD / J BOX THERMO- WELL SST ACCELABAR KEP ES749 Flow Computer 26
27 27
28 28 University Steam Piping
29 Natural Gas Installation 6 0, 000 to 1, 0 00SCF H (Turndown 6 0 : 1) No straight run Natural gas to LNG heaters F 2 stacked transmitters H : H 2 0 Replaced a turbine meter that was unable to cover the turndown and handle the short straight run 29
30 30 Installation below ground in vault flanged between butterfly and gate valve
31 31 NASA high pressure (6000PSIG) nitrogen flow Accelabar for fire suppression
32 Accelabar Applications Mayo Industries Loveland, CO Two 3 Accelabars with IMV25 transmitters measuring and blending land fill gas and natural gas Space requirement was at a minimum Skid mounted 32
33 33 2 X 1 Hastelloy C Accelabars U.S. ARMY CHEMICAL WEAPONS DESTRUCTION
34 34 API 22.2 test at CEESI
35 Accelabar Summary FEATURES 1) No Straight Run required 2) Five Year Performance warranty from date of invoice. 3) No pipe reduction required. 4) Single source responsibility. 5) High Flow turndown (Up to 65:1) 6) No field calibration required 7) 0.5% of Rate accuracy. 8) Pre configured, install, start up, walk away. 9) Pulse, Analog, Modbus/Bacnet options. 35
36 36 Armstrong Vortex Meter
37 Armstrong Vortex Meter A Little History Lesson: Vortices were first observed by Leonardo De Vinci in the early 1500 s About 400 years later Theodore von Kármán observed the repeating pattern of swirling vortices caused by the unsteady separation of flow of a fluid around blunt bodies, named the von Kármán vortex street 37
38 38 Armstrong Vortex Meter
39 39 Armstrong Vortex Meter
40 40 Armstrong Vortex Meter
41 Armstrong Vortex Meter Steam, water, gas measurement Sizes ½ to 12 Temps -330 F to 750 F Up to ANSI Class 600 Multivariable options: Velocity, Temp, Pressure, Temp & Pressure, BTU Velocity, temperature, pressure measurements integral to meter body Outputs: Loop powered 4-20 ma, Relays, Pulse output, HART, MODBUS, BACnet 1.5% of rate accuracy or better Turndown up to 100:1 (application dependent) Push button digital display Remote electronics available FM, FMC, ATEX, IECEx Approvals In Process 41
42 42 Armstrong Vortex Meter
43 43 Armstrong Vortex Meter
44 Complete Flow Offering VERIS Verabar 1991 VERIS Accelabar 2004 Armstrong Vortex Meter Venturi Tube Wedge Meter 2017 Flow Nozzle Orifice Plate 44
45 6315 Monarch Park Place Niwot, Colorado USA Phone: (303) Cell: Website: armstronginternational.com/veris Contact: Jon Zoppa 45
Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement
Velocity Averaging Sensors True Performance in Measurement ...Advanced DP Measurement The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology,
More informationVERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT
VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the
More informationArmstrong In-Line and Insertion Vortex Flow Meters
Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line
More informationV200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)
VERIS Verabar Hot Tap Models V200 Screw Drive Threaded Components The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the VERIS Verabar averaging
More informationModel Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy
VERIS Verabar Hot Tap Models V400 Screw Drive Flanged Components The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the VERIS Verabar averaging
More informationRosemount 285 Annubar Primary Element Series
0013-0100-02, Rev CA Rosemount 25 Annubar Primary Element Series Designed for general purpose applications Increased plant uptime with the maintenance-free design Energy savings gained through minimal
More informationVERIS FLOW MEASUREMENT GROUP
VERIS FLOW MEASUREMENT GROUP TRUE PERFORMANCE IN FLOW MEASUREMENT 1 Table of Contents VERIS Flow Measurement Group VERIS Accelabar...3-4 VERIS Verabar...5-6 In-Line Vortex Flow Meter...7 AVF Specifications...8
More informationRegular Models. V150 Spring Lock Threaded Components
VERIS Verabar Regular Models V150 Spring Lock Threaded Components The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the VERIS Verabar averaging
More informationV550 Spring Lock Flanged Connection with Packing Gland
VERIS Verabar Flanged Models V550 Spring Lock Flanged Connection with Packing Gland The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration
More informationPro-V Multivariable Flowmeter Model M24 In-line Vortex
Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an
More informationNC State University Design and Construction Guidelines Division 23 Energy Management
1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have
More informationAccutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs
s Meriam s Flow Sensors are lab-tested and field-proven flow elements perfect for gas, liquid or steam service. With thousands in use worldwide, the continues to be the right choice when ease of installation,
More informationAveraging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA
Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA WHAT IS A TORFLOW? TheTORFLOW is a multiport self-averaging flow meter with a design based on the classical pitot tube concept of fluid flow measurement.
More informationF-2500 SERIES VORTEX METER
F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationVortex Flow Meter Model DVH
Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400
More informationMid-West Instrument FLOW MEASUREMENT PRODUCTS PRECISION FLOW TEST KITS VERABAR FLOW SENSORS
FLOW MEASUREMENT PRODUCTS MODEL 300 PRECISION FLOW TEST KITS VERABAR FLOW SENSORS For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Mid-West Product Notes:
More informationModel CO Compact Orifice for use with Foxboro Differential Pressure Transmitters
Product Specifications Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters PSS 3-5A1 E MODEL CO WITH TRADITIONAL STRUCTURE MODEL CO WITH LOW PROFILE STRUCTURE (LP1) MODEL CO
More informationV500 and V510 VERIS Verabar Installation and Maintenance Manual
V500 and V510 VERIS Verabar Installation and Maintenance Manual 167-EN Please read and save these instructions Contents General Safety Information...3 Product Information...3 Section 1: Scope...3 Purpose
More informationVIM20 Vortex Insertion Flowmeter
VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationHot Tap Insertion Vortex
Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationModel FVP General Specification. Flanged Vortex Plate. Product Features
Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from
More informationVortex Flowmeter Model DVE
Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...
More informationVORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment
VORTAB FLOW CONDITIONERS For Flow Meters, Pumps and Other Flow Profile Critical Equipment Reduce flow meter straight-run requirements into just a few diameters Balance pump inlet flow to eliminate premature
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationKB Series self averaging pitot flowmeter for gas, liquids and steam flows
process measurement solutions K Series self averaging pitot flowmeter for gas, liquids and steam flows Data sheet IP371 Advantages of the K series Description Patented square sensor design - reliable accuracy
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationFundamental Training. Flow Con t
Fundamental Training Flow Con t 1 Contents Topics: Slide No: Velocity flow meters 3-11 Mass flow meters 12-17 Displacement meters 18 Exercise 19-20 2 Velocity Meter Magnetic Flowmeter Faraday s Law of
More informationDVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max
Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationElectro-Magnetic Flowmeters Sensors MagMaster MFE
Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2-
More informationVortex Plate. Model VP General Specification. Product Features
Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals
More informationTransmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell
Transmitters Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell Oldest design, developed during WW 2. Can be used for flow, level, and pressure, vent low side. Several ranges 0 to
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationF L O W M E T E R I N G E Q U I P M E N T Model AR Ellipse Annular Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement
More informationV150 VERIS Verabar Installation and Maintenance Manual
V150 VERIS Verabar Installation and Maintenance Manual 164-EN Please read and save these instructions Contents General Safety Information...3 Product Information...3 Section 1: Scope...3 Purpose of this
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in
More informationPanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits
Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to
More informationVORTEX IN-LINE FLOW METERS
VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase
More informationField IT Electro-Magnetic Flowmeters Sensors
Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.
More informationCOMPANY PROFILE PT. INAKO PERSADA
COMPANY PROFILE PT. INAKO PERSADA www.inakopersada.com COMPANY OVERVIEW PT. INAKO PERSADA as a Industrial Supplier Company, Committed to providing the Industrial Equipments(Mechanical, Electrical, Instruments&
More informationflow measurement solutions RIM10 series rotor insertion flowmeters
flow measurement solutions RIM10 series rotor insertion flowmeters R I M 1 0 RIM10 series rotor insertion flowmeters Versatile enough for almost any challenge Spirax Sarco s RIM10 rotor insertion flowmeters
More informationVortex In Line Flow Meter
Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase
More informationOAKLEAF INVESTMENT HOLDINGS 52 (Pty) ltd
REV. 04 04 14 OAKLEAF INVESTMENT HOLDINGS 52 (Pty) ltd is by contract the exclusive import agent and service provider in South Africa for various foreign specialist manufacturers of FIELD PROCESS MEASURING
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationFundamentals of Natural Gas Measurement
Fundamentals of Natural Gas Measurement Why Measure Natural Gas? Production Gathering Processing Purchase Sales Transportation Exchange Distribution Check Measurement System Physical Balance System Control
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationVortex In Line Flow Meter
Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting
More informationF-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide
FLOW AND ENERGY MEASUREMENT F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 www.onicon.com
More informationInstruction Manual Vortex Flow Meter DVH / DVE
Instruction Manual Vortex Flow Meter DVH / DVE Customer Notice for Oxygen Service Unless you have specifically ordered Heinrichs` optional O 2 cleaning, this flow meter may not be fit for oxygen service.
More informationVorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters. Instruction Manual
Table of Contents VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters Instruction Manual Document Number M-000-00010 Rev 8/2018 8475 W I-25 Frontage Rd Suite 300 Longmont, CO 80504
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationAir Flow Measurement Technologies
Page 1/7 Typical Air Flow Measurement Applications Air Flow Control True Flow Feedback Theory of Vortex Shedding Air Flow Measurement Pitot Air Flow Measurement Thermal Air Flow Measurement Advantages
More informationTechnical Data Sheet , Rev HB October Rosemount 8800 Vortex Installation Effects
Technical Data Sheet 00816-0100-3250, Rev HB October 2018 Rosemount 8800 Vortex Installation Effects 2 Technical Data Sheet Contents 00816-0100-3250 October 2018 Contents Chapter 1 Introduction... 5 1.1
More informationModel 5000 Vortex Meter
Model 5000 Vortex Meter Installation and Instruction Manual Table of Contents General Information... 1 1-1 General... 1 1-2 Principles of Operation... 1 1-3 Sensor Operation... 1 1-4 Calibration Factor...
More informationSKYLINE FLOW CONTROLS INC.
SKYLINE FLOW CONTROLS INC. PRODUCTS BRIEF SFC Series Flow Meters. SFC series Flow Meters include :Venturi meters, Wedge meters, Rect. Meters, Nozzle Flow Elements and Orifice Flow Elements. 1 VENTURI FLOW
More informationRosemount Orifice Series Differential Pressure Flow
Rosemount Orifice Series Differential Pressure Flow Innovative Offering for Better Measurement Revolutionizing the Industry Workhorse Orifice Plate Technology It s no coincidence that orifice plates are
More informationPSF50 Paddle flow switch
Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up
More informationV400D VERIS Verabar (Double Rod) Installation and Maintenance Manual
V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual 168-EN Please read and save these instructions Contents General Safety Information...3 Product Information...3 Section 1: Scope...3
More informationFeatures/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS
Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed
More information240/241 Series Vortex Volumetric and Mass Flow Meters. Instruction Manual
Sierra 240/241Series Instruction Manual Table of Contents 240/241 Series Vortex Volumetric and Mass Flow Meters Models: 240-V, VT, VTP, LP / 241-V, VT, VTP, LP, Cryogenic Instruction Manual Document Number
More informationVortex Eggs Delta Flowmeter
Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Digital Vortex meter digitalyewflo Digital Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/ Series Simple body construction for easy installation and high level of safety 2 3 Standard Type /
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ
More informationDVH / DVE. Vortex Flow Meter. Instruction Manual. Page 1 of 102
Vortex Flow Meter DVH / DVE Instruction Manual Page 1 of 102 Contents 1 IDENTIFICATION... 5 1.1 Supplier / Manufacturer... 5 1.2 Producttype... 5 1.3 Issue date... 5 1.4 Version No.... 5 1.5 Tagging /
More informationDatasheet Rev.3 Feb 2015 Venturi tube
Datasheet Rev.3 Feb 2015 Venturi tube Venturi tube design based on IS5167, ASME.MFC.3M and IS TR15377 :2007 industry standards No need for calibration standardised principle Accuracy, repeatability and
More informationAccutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station
Accutrol, LLC Product Sheet VTS Series US Patents 6,991,177 & 7,543,759 Digital Airflow Measurement Station Innovative features of the AccuStation VTS Series! Digital Airflow Sensing Modular Design Intuitive
More informationFluid Flow Conditioning
Fluid Flow Conditioning March 2014 Flow Conditioning There is no flow meter on the market that needs flow conditioning. All flow meters are effective without any type of flow conditioning. 1 Flow Conditioning
More informationRosemount 585 Annubar Flanged Flo-Tap Assembly
Quick Installation Guide 00825-0200-585, Rev AA Flanged Flo-Tap 585 Annubar Rosemount 585 Annubar Flanged Flo-Tap Assembly Start Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3:
More informationSmartCone Differential Pressure Flow Meter User Manual
SmartCone Differential Pressure Flow Meter User Manual Page 1 Table of Contents Section 1 - SmartCone Introduction... 4 1.1 Introduction... 4 1.2 SmartCone - Meter Components... 4 1.3 Principles of Operation...
More informationManifold and Isolation Valve Mounting System for Direct Mounting DP Transmitters
ANDERSON GREENWOOD INSTRUMENTATION PRODUCTS for Direct Mounting DP Transmitters Introduction The Anderson Greenwood SaddleMount has been developed to overcome the problems associated with traditional transmitter/manifold
More informationSERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX
F- SERIES INSERTION TURBINE instructions -0XX -1XX Table of Contents GENERAL INFORMATION General Information Features, Specifications... Page 1 Installation Piping, Immersion, Positioning the Meter...
More informationModel 1000 Vortex Meter
Model 1000 Vortex Meter Installation and Instruction Manual Table of Contents General Information... 1 1-1 General... 1 1-2 Principles of Operation... 1 1-3 Sensor Operation... 1 1-4 Calibration Factor...
More informationTX 115/215 Hot-tap Insertion Turbine Instructions
TX 115/215 Hot-tap Insertion Turbine Instructions General Information These hot tap versions of the proven TX insertion flow sensors are designed to install or be serviced without depressurizing the pipe.
More informationCondensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter
Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter Warranty Agreement J-TEC Associates warrants this product to be in good working order for a period of
More informationRosemount 405 Compact Orifice Series
Reference Manual Rosemount 405 Compact Rosemount 3051SFC Compact Orifice Flowmeter Rosemount 3095MFC Compact Orifice Mass Flowmeter www.rosemount.com Reference Manual Rosemount 405 Compact Rosemount 405
More informationRIM20 Rotor Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationV200D VERIS Verabar (Double Rod) Installation and Maintenance Manual
V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual 173-EN Please read and save these instructions Contents General Safety Information...3 Product Information...3 Section 1: Scope...3
More informationRosemount 3051CFA Annubar Flowmeter
December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.
More informationFLOW TEK VALVES & CONTROL S INC
FLOW TEK VALVES & CONTROL S INC e-mail:- info@flowagevalves.com PLOT NO-172,173, ROAD NO-4, KATHWADA, G.I.D.C. AHMEDABAD. PHONE NO:- 079-22900219,22900220, MOBILE:-09824539702, 9824080899. an ISO 9001
More informationTX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY
TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY TABLE OF CONTENTS General Information Features, Specifications...Page
More informationBYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES
BULLETIN 20-5100-68 BYPASS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES BYPASS ROTOMETERS SK bypass Rotameter systems are designed for the accurate measurement of fluid rate of flow in pipelines 11/2
More informationFUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions
FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions 6677 N. Gessner, Houston, Texas 77040 Throughout the oil and gas industry, there stems the need for accurate, economical measurement
More informationINSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT)
Gas and Liquid Measurement Catalog SOLUTIONS FOR: - PRODUCTION - REFINERIES - DISTILLERY - TRANSPORTATION AND STORAGE - OIL DEPOTS - DISTRIBUTION. Engineered Solutions. ORIFICE METERS ULTRASONIC METERS
More informationFUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems
FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems 9303 W. Sam Houston Parkway, Houston, TX 77099 INTRODUCTION The insertion turbine meter is well suited for
More informationVortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Vortex meter digitalyewflo Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/fld Series Simple body construction for easy installation and high level of safety 2 Standard Type / Multi-variable
More informationRosemount DP Flowmeters and Primary Elements
meters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters allow for easy installation Minimize permanent pressure
More informationVorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual
Series M22/M23 Instruction Manual Table of Contents VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters Models M22-VT, M22-VTP, M23-VT, M23-VTP Instruction Manual Document
More informationTransmitting Transducer. Gas/Air Velocity Range:
RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters
More information