1 EQUAL DISTRIBUTION OF WASTEWATER USING LOW-PRESSURE DISTRIBUTION Larry D. Stephens, P.E. * INTRODUCTION Experience with onsite systems has proven that equal application of wastewater over the entire soil absorption area will provide better treatment, will enhance aerobic conditions in the soil, and will provide greater longevity of the soil absorption system. This can be accomplished by the use of low-pressure dosing techniques using pump(s) and a network of small diameter PVC, pressure-rated pipe with small diameter orifices drilled at equal spacing along the laterals. The size and length of the laterals and the size and spacing of the orifices can be specifically chosen to achieve equal distribution for most site conditions. The designer must keep several principles in mind with regard to the design of pressure distribution systems: 1. At any given system pressure the discharge exiting an orifice will vary significantly with the hole size. The number and size of the holes will affect the lateral and forcemain sizes and the size of the pump required to dose the system. 2. The size of the pipe used in the system will affect the head that the chosen pump is required to meet for any given number and size of orifices. The smaller the forcemain and manifold pipe diameter --- the higher the head-loss at any given flow rate. And, the smaller the lateral diameter, the greater the head difference from one end of the lateral to the other, leading to a greater flow differential between the first and last hole in a lateral. A large head-loss across a lateral will mean less than equal distribution. 3. On the other hand, smaller laterals will have higher scouring velocities that tend to prevent the deposition of solids that may clog orifices. With all this in mind, the designer s job is to balance the hole size and spacing, the pipe sizes chosen, and the pump specifications to achieve efficient and sufficient equal distribution. If good effluent screens are used on the septic tank outlets, or if sufficient additional treatment is provided beyond the septic tank proper, smaller diameter orifices can be used in the distribution pipe network to keep the pump size to a minimum. It is common to use 1/8 to 3/16 orifices in such cases. However, if screening or filtering is not provided, hole sizes should be kept larger in the range of 1/4 to 5/16 diameter. Hole sizes larger than this usually result in excessive pump size requirements. Orifice spacing along the laterals usually vary between 2 feet on center to as much as 6 feet on center, with 3 to 5 feet being the most common. This is a designer s choice, however, the closer the orifice spacing the more infiltrative surface will be used from the first day of system use. * Larry D. Stephens, P.E., President, Stephens Consulting Services, P.C., P.O. Box 708, Haslett, Michigan, Phone: (517) , scscons@yahoo.com 1
2 In some cases it may be beneficial to use an automatic hydraulic alternating valve to dose zones of the soil absorption system in sequence. In this way, the pump only has to be sized to dose one zone at a time. If sufficient slope is available through the tanks, and between the tanks and the soil absorption system, siphons may be used in lieu of a pump. The use of a siphon will normally require several feet of fall to work properly. If a siphon is used, care must be taken to install the device according to the manufacturer s recommendations. It is also recommended that larger orifices be used in the distribution piping network if a siphon is used (3/8 to 1/2"), because a siphon does not develop higher pressure like a pump if the holes begin to clog. With regard to the orientation of the holes in the laterals, some argue that placing the holes up in the 12 o clock position, or sideways at the 3 or 9 o clock positions will provide longer service life between maintenance events. Others argue they have not observed this benefit, and that positioning the holes down in the 6 o clock position allows the laterals to drain between pump cycles and prevents freezing in cold climates. If the holes are oriented in the up position, the feed lines from the dosing tank, the manifold and the laterals should be laid to drain back to the tank between pump cycles where freezing conditions may occur. It has also been proven that aerobic conditions and better treatment are encouraged in the soil absorption system by micro-dosing of the system. This is accomplished through the use of a programmable timer in the pump control box. The adjustable timer controls the pump cycle frequency and the pump run time such that small, measured doses can be delivered to the soil absorption system throughout the day. In this way, flow to the soil absorption system is equalized at the pump tank to a great extent, and peak flow events are spread over longer periods of time. When timers are used, the doses are kept as small as practical. The time of each dose must consider the time it takes to prime the forcemain and the distribution laterals during each pump cycle. Pressure Distribution Design Procedure 1. Select the number and length of the laterals to be used. These choices will generally depend upon the shape and size of the soil absorption system. The closer the laterals are together, the better the distribution that can be expected, but the greater the pump size necessary to deliver the required flow (generally speaking). Lateral spacing typically ranges from 8 to 12 feet for trench-type systems, and 3 to 5 feet for bed-type systems. Laterals usually start and end 1 to 3 feet from the end of the stone, depending upon the orifice spacing chosen, with the first and last orifices near the ends. 2. Select the orifice diameter and orifice spacing for the laterals. Orifice spacing in bed-type systems usually approximates the lateral spacing to provide a grid of application points that is uniform in both directions. The greater the number of orifices, the larger the pump required for any given orifice size. The larger the orifice size, the greater the pump size 2
3 required to maintain design pressure. Orifice diameters of 1/8 to 1/4, and an orifice spacing of 3 to 6 feet is the most common. 3. Calculate the lateral discharge rate. To accomplish this, you must first choose a residual head that you wish to maintain in the distribution system. The residual head is the head (in feet of water) that you wish to maintain at the end of each of the laterals. Some designers call this the squirt height, or the height that water will squirt out of an upward facing orifice in the far end of the lateral. The squirt height is usually slightly less than the actual driving head inside the lateral, and will decrease slightly from the upstream to the downstream end of the lateral due to friction loss in the pipe. Residual heads for systems with larger orifices are usually chosen to be in the 2 to 4 foot range. When smaller orifices are used in the laterals, a larger residual head of 5 feet or more can be used for design. The lateral discharge rate is determined by multiplying the discharge per orifice by the number of orifices in each lateral. The orifice discharge rate can be found in Table 1 for a wide range of head pressures. The designer must keep in mind that a greater pressure head must be maintained at the upstream end of the lateral to maintain a minimum residual pressure at the downstream end. This does result in a little greater discharge out of the upstream orifices than those near the end of laterals. The difference should be less than 10% with a good design. This additional flow must be considered in choosing the pump for the job. A simple and conservative way of accommodating the difference in lateral flow caused by the head-losses in the lateral as described above is to add 10% to the lateral flow. 4. Determine the total required flow. This number is determined by multiplying the lateral discharge rate calculated in #3 by the number of laterals you have chosen. This will be the flow the pump will be required to deliver. As you consider the pump size required at this point, decide if it is acceptable. If not, go back to step #1 or #2, make the required changes in the number of laterals, or the number, size and/or spacing of orifices, and recalculate until you have an acceptable result for pump size. 5. Determine the lateral diameter. Smaller laterals have more friction loss in the pipe from end to end (tending to reduce equality in distribution), but have higher velocities which tend to do a better job of scouring the inside of the pipe and keeping it cleaner. A compromise between these objectives must be chosen. A generally accepted goal is to allow no more than a 10% difference in flow rate between the first and last orifice in a lateral. Table 2 shows the calculated flow velocity and head loss for a variety of pipe sizes and flows. This particular table is based upon actual inside pipe diameters of Schedule 40 PVC pipe. If another type of pipe is used, be sure to check and use the actual inside diameter for friction loss calculations. For longer lengths of pipe, it can make a significant difference in the performance of the system. 6. Choose a manifold size and configuration. Use of a center manifold with laterals feeding in two different directions usually provides better distribution. However, on smaller systems, or due to specific site circumstances, it may be desirable or necessary to use an end manifold. This will usually result in longer laterals that will have more pressure loss from one end to the other. The goal of the manifold is to equally distribute the wastewater to all of the laterals. Feeding the manifold with the forcemain connection from the dosing tank at 3
4 the center is usually best. For individual homes with only 2 to 6 laterals, a manifold the same size as the laterals may be acceptable. But for larger systems, a manifold 1 to 3 pipe sizes larger may be needed. Table 2 will give you an idea of how much head loss you can expect in the various sizes of pipe. To determine the amount of head loss, estimate how much flow will be going through a section of pipe, and then multiply the head loss per foot found in the table for the size pipe used by the number of feet of pipe. Compare this with the loss in the next section, etc., to decide if it is within acceptable limits. 7. Calculate the pump size in discharge rate (GPM) and total design head (TDH). The required discharge rate was calculated in #4 above, and is the sum total of all of the lateral discharge rates. The total design head (TDH) is the sum of the following: The number of feet that the pump must lift the wastewater from the low water elevation in the dosing tank to the lateral elevation in the soil absorption system (Static ); plus The number of feet of required pressure at the manifold to achieve equal distribution in the laterals (Residual, plus the head-loss in the lateral); plus The friction loss in the forcemain, fittings, and valves between the dosing tank and the soil absorption system (Friction Losses). Static : This will require that you know the elevation of the low water level expected in the dosing tank, and the elevation of the proposed soil absorption system laterals. Subtract one from the other to obtain the Static. (Note: If this number is a negative number, meaning you are pumping downhill, you will need to take extra precautions to prevent siphoning of the dosing tank contents after a pump cycle. A vacuum breaker or vent hole at a high point in the pump discharge piping may do the trick.) Residual : This number will match the head you chose in #3 above as a driving head to pressurize the system of laterals. Friction Losses: Friction losses are the result of resistance to the movement of liquid through pipes due to the friction of the liquid along the pipe walls. This resistance is greater with increases in velocity caused by smaller pipes, and conversely less with lower velocities. It does vary with different materials, but PVC is the most commonly used material in wastewater applications, and has very good flow characteristics. Table 2 gives the estimated friction loss per foot of pipe for various pipe sizes and a wide range of flow rates. The flow rate was determined in #4 above. Choose a forcemain pipe size that will not result in an unreasonable amount of head loss for the required flow rate. To calculate the head loss for the forcemain, measure the length of the forcemain required, chose a size, find the head-loss per foot from Table 2, and multiply the length by the number from the table. (Note that this table is again based upon Schedule 40 PVC pipe. If any other pipe material or specification is used, these numbers must be modified accordingly for the inside pipe diameter for the 4
5 material chosen). All installations also have a number of valves and fittings that add head loss to the pipe losses. The procedure for calculating these is somewhat complicated, but experience has shown that adding 10% to 20% to the forcemain losses is usually sufficient. If an automatic hydraulic sequencing valve is used in the design, a substantial amount of additional head loss through the valve will need to be accommodated in the pump size. Refer to the manufacturer s literature for the valve chosen to determine how much additional head loss to add. If this result requires excessive design head, choose a larger pipe size and repeat the calculation. The larger these numbers, the larger the pump required in horsepower. With regard to forcemain size, it is also desirable to keep velocities between 2 and 8 feet per second. Slower velocities may result in the accumulation of solids in the pipe, and higher velocities can actually result in pipe wall scouring. Now, add the Static, the Residual, and the Friction Losses, to get the Total Design required for the pump. Remember --- both the required flow and the TDH are used to choose a pump. These two criteria will allow the designer and supplier to choose the correct pump for the job. 8. Evaluate the design for efficiency and adequacy of distribution. Step back at this point and look at the results you obtained. Does the number and spacing of laterals and orifices provide sufficiently equal distribution? Is the pump size reasonable for the application? If necessary, make some appropriate changes and repeat the necessary steps to arrive at an optimum design. EQUATIONS USED Flow through an orifice is determined using the orifice equation as follows: Q = CA(2gH) 1/2 Where: Q = Discharge (ft 3 /s) C = Discharge Coefficient (Assumed to be 0.6 in this calculation) A = Orifice Area (ft 2 ) g = Gravitational acceleration (32.2 ft./s 2 ) H = on Center line of Orifice (ft) loss in pipe is calculated by using the flow, the pipe diameter and a friction factor. The Hazen Williams formula allows the designer to calculate headloss as follows: h = kq x 5
6 Where: h = head loss (ft.) Q = discharge (ft 3 /s) x = reciprocal of the exponent of the hydraulic slope in the friction formula (for Hazen Williams, x = 1.85) And where k is the constant calculated from the following equation: k = (1594/C) 1.85 *(l/d 4.87 ) Where: C = Hazen Williams coefficient for the pipe material used (C = 150 used here for PVC pipe) l = pipe length (ft) d = diameter (in) SPREADSHEET APPLICATION With a little effort, the design engineer can develop a spreadsheet using Microsoft Excel, or similar, software to perform these calculations expeditiously. Such tools will make the designer s job easier and more enjoyable, and will reduce the opportunity for error. This writer has created such a spreadsheet, and is willing to share it with those interested for a nominal cost. Contact the writer at the address listed on page 1. Table 1. Orifice Discharge Table Given in G.P.M. 6
7 Pressure (psi) Pressure (ft) Hole Diameter (inches) 1/8" 3/16" 1/4" 9/32" 5/16" 11/32" 3/8" Conversions 1 psi = 2.3 ft. of water 1 ft. of water = 0.43 psi Table 2. Forcemain Loss Calculations 7
8 Flow (gpm) Loss per foot of pipe (ft.) Schedule 40, PVC Pipe 1" Pipe 1-1/4" Pipe 1-1/2" Pipe 2" Pipe Fluid Velocity (ft/sec.) Loss per foot of pipe (ft.) Fluid Velocity (ft/sec.) Loss per foot of pipe (ft.) Fluid Velocity (ft/sec.) Loss per foot of pipe (ft.) Fluid Velocity (ft/sec.) Conversions 1 psi = 2.3 ft. of water 1 ft. of water = 0.43 psi 8
Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS
Washtenaw County Department of Planning & Environment Development Services Division DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS 705 N. Zeeb Road Phone: (734) 222-3800
More informationPressure Distribution Design
1 Pressure Distribution Design 2 Let s Start with Nonpressurized systems Historically the norm 3 Distribution Systems 4 Distribution Systems Non-pressurized Distribution Non-pressurized Distribution (cont.)
More informationWorksheet for pressure distribution system design Long form with instructions and tables Rev. August 2007
Job: Date: Designer: Design number: Option number: Worksheet for pressure distribution system design Long form with instructions and tables Rev. August 2007 This is an iterative process, so each step might
More informationPUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.
PUMP TYPES Sump Clean Water Only Systems that need a Lift Effluent Multi stage Single stage Sewage Grinder Pumping to Gravity Distribution When STA is at higher elevation than septic tank Pump Sizing TDH
More informationPressure Distribution. Western Canada Onsite Wastewater Management Association
Pressure Distribution EFFLUENT DISTRIBUTION Get even distribution Space the doses Layout the distribution system Make choices for: piping, orifices, volumes Use worksheets for calculations Dose or flush
More informationPRESSURE DISTRIBUTION COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS (VERSION 2.0) January 30, 2001
PRESSURE DISTRIBUTION COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS (VERSION 2.0) January 30, 2001 State of Wisconsin Department of Commerce Division of Safety and Buildings SBD-10706-P
More informationAMERICAN RECIRCULATING SAND FILTER SYSTEMS
American Manufacturing Company, Inc. P.O. Box 549, Manassas, VA 20108 1-800-345-3132 AMERICAN RECIRCULATING SAND FILTER SYSTEMS ENGINEERING DESIGN GUIDELINES FOR COMMUNITY AND COMMERCIAL SIZED TREATMENT
More informationOrenco Automatic Distributing Valve Assemblies
This article may describe design criteria that was in effect at the time the article was written. FOR CURRENT DESIGN CRITERIA, call Orenco Systems, Inc. at 1-800-348-9843. Orenco Automatic Distributing
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)
CSO/STORMWATER MANAGEMENT HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G) HYDROVEX FLUIDMID FLOW MONITORING & REGULATING STATION WITH SIPHON (TYPE G) APPLICATION The HYDROVEX
More informationComponents of Hydronic Systems
Valve and Actuator Manual 977 Hydronic System Basics Section Engineering Bulletin H111 Issue Date 0789 Components of Hydronic Systems The performance of a hydronic system depends upon many factors. Because
More informationFlood Dosed System Worksheet
Number of bedrooms Flood Dosed System Worksheet Septic tank size Minimum 1000 gallons Dosing tank size Minimum 800 gallons or 1 bedroom smaller than septic tank size whichever is larger Filter: gravity(in
More informationWATER SYSTEM SIZING Introduction Residential Water System Sizing
WATER SYSTEM SIZING Introduction It is crucial that water supply systems are properly sized. Well owners are often concerned about whether or not there will be enough water for their needs. The area geology
More informationLow-Cost Pipeline Flow Meter
Low-Cost Pipeline Flow Meter By Tony L. Wahl 1 and Henry Magallanez 2 A new low-cost flow meter is being used to measure flows in the discharge pipelines from wells located on the Elephant Butte Irrigation
More informationARIES THINWALL DRIPLINE
N E T A F I M U S A ARIES THINWALL DRIPLINE TM REVOLUTIONARY TURBUNEXT TM TECHNOLOGY IN A NON-COMPENSATING SETS A NEW STANDARD FOR CLOG RESISTANCE AND ENHANCED PERFORMANCE ARIES TM THINWALL DRIPLINE Netafim
More informationSAE Baja - Drivetrain
SAE Baja - Drivetrain By Ricardo Inzunza, Brandon Janca, Ryan Worden Team 11 Engineering Analysis Document Submitted towards partial fulfillment of the requirements for Mechanical Engineering Design I
More informationPump Control Ball Valve for Energy Savings
VM PCBVES/WP White Paper Pump Control Ball Valve for Energy Savings Table of Contents Introduction............................... Pump Control Valves........................ Headloss..................................
More informationAir Cylinders Drive System Full Stroke Time & Stroke End Velocity. How to Read the Graph
1-1 Best Pneumatics Air Cylinders Drive System Full Time & End Velocity How to Read the Graph This graph shows the full stroke time and stroke end velocity when a cylinder drive system is composed of the
More informationPump ED 101. Variable, Fixed Speed Control - - Float Switch Activation. Introduction
Pump ED 11 Variable, Fixed Speed Control - - Float Switch Activation Joe Evans, Ph.D http://www.pumped11.com Introduction It has been said that there is more than one way to skin a cat. In fact, there
More informationSelf Cleaning Hood System Installation, Operation, and Maintenance Manual
Self Cleaning Hood System Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to
More informationAR No. # Low Pressure Irrigation
AR No. # Low Pressure Irrigation Recommendation Install a variable speed drive (VSD) on the 25 hp submersible pump. This will allow the system to operate at a lower pressure, delivering the same water
More informationThe Watter Buddy. Owner s Manual. Please Read Carefully. Made in North America. PO Box 4557 Sussex NB Canada E4E 5L7
The Watter Buddy Owner s Manual Please Read Carefully Made in North America By PO Box 4557 Sussex NB Canada E4E 5L7 Phone +1 (506) 433-3151 Fax +1 (506) 433-6151 Email: support@microhydropower.com Website:
More informationMotorcycle ATV Braking Data Analysis. Progress Report
Motorcycle ATV Braking Data Analysis Progress Report Mark D. Osborne And Russ G. Alger Keweenaw Research Center Houghton, MI 49931 February 14 TABLE OF CONTENTS Page 1. INTRODUCTION... 1 2. MOTORCYCLE
More informationAir Cylinders Drive System Full Stroke Time & Stroke End Velocity. How to Read the Graph
1 Best Pneumatics Air Cylinders Drive System Full Time & End Velocity How to Read the Graph This graph shows the full stroke time and stroke end velocity when a cylinder drive system is composed of the
More informationVENT SILENCER PRODUCT GUIDE
VENT SILENCER Copyright 200 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited. PRODUCT GUIDE PULSCO VENT SILENCER TABLE OF CONTENTS DESCRIPTION PAGE PULSCO VENT
More informationD-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features
PN 16 / 25 Wastewater Combination Air Valve for Wastewater PATENTED EuroC-D023SWG-15-2 Description The D-023 Combination Air Valve combines an air & vacuum component and an air release component in a single
More informationE-Z Treat Installation Guidelines
E-Z Treat Installation Guidelines E-Z Treat Company or its representative will conduct on-site training with each installer before they are certified to install E-Z Treat systems. The training will include
More informationModel AM2 M40 Panel Installation, Operation, and Maintenance Manual
Model AM2 M40 Panel Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to the
More informationSHAFT ALIGNMENT FORWARD
Service Application Manual SAM Chapter 630-76 Section 24 SHAFT ALIGNMENT FORWARD One of the basic problems of any installation is aligning couplings or shafts. Therefore, this section will endeavor to
More informationFUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions
FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions 6677 N. Gessner, Houston, Texas 77040 Throughout the oil and gas industry, there stems the need for accurate, economical measurement
More informationCHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER
CHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER 1. Scope : This Chapter describes the methods to measure the resistance to the progress
More informationCalibration of Chemical Applicators Used in Vegetables1
HS12 Calibration of Chemical Applicators Used in Vegetables1 M. R. Miller and P. J. Dittmar2 includes information about calibration to help growers properly apply pesticides. Definition of Terms GPA: Gallons
More informationSTEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE
STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE 2 This report will discuss the results obtained from flow testing of a 12 IBC valve at Alden Research
More informationCity of St. Pete Beach Model Capacity Report Addendum
Model Capacity Report - Addendum City of St. Pete Beach Model Capacity Report Addendum Prepared for: City of St. Pete Beach 155 Corey Avenue St. Pete Beach, FL 33706 Prepared By: Kimley-Horn and Associates,
More informationEngineering & Design Data
PVC & CPVC Corrosion Resistant Industrial Pressure Pipe Engineering & Design Data Engineering & Design Data Hydraulic Shock Hydraulic shock is the term used to describe the momentary pressure rise in a
More informationPROVISIONAL PATENT APPLICATION INVENTORS: RICHARD E. AHO CAVITATION ENGINE
PROVISIONAL PATENT APPLICATION INVENTORS: RICHARD E. AHO WILLIAM WALTER MEE FOR CAVITATION ENGINE Richard E. Aho 4170 N.W.42 St. Lauderdale Lakes, FL 33319 William Walter Mee 8591 Pioneer Road West Palm
More informationSeptic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks
Septic Tanks Gravity treatment Separation Sludge sinks Scum floats Storage Septic Tanks, Holding Tanks & Pump Tanks Bacteria SCUM breakdown CLEAR ZONE Chemical SLUDGE WW Strength= Organic Load Effluent
More informationPiping Systems in Dewatering Applications
Piping Systems in Dewatering Applications Pump System Improvement by Ray Hardee Engineers involved with any project that includes more than a cursory amount of digging must consider how to manage groundwater.
More informationEJECTORS GENERAL OPERATION & MAINTENANCE MANUAL
EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be found on
More informationThe Discussion of this exercise covers the following points:
Exercise 3-3 Venturi Tubes EXERCISE OBJECTIVE In this exercise, you will study the relationship between the flow rate and the pressure drop produced by a venturi tube. You will describe the behavior of
More informationLEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.
LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL www.enoscientific.com Eno Scientific PO Box 1586 Hillsborough, NC 27278 USA www.enoscientific.com 910-778-2660 Copyright Notice Copyright 2015 Eno
More informationBERMAD Waterworks. 800 Series. Technical Specifications Metric
Technical Specifications SI 800 Metric Series Patterns and Sizes "Y" Pattern DN40-500 Angle DN40-450 Connection Standard Flanged: ISO 7005-1(ISO 10, 16, 25 & 40) Water Temperature Up to 80ºC Working pressure
More informationENGINEERING DATA ENGINEERING DATA
ENGINEERING DATA 173 Average Depth 3.5 ft. 24 ft. Dia. ESTIMATING TOTAL GALLONS IN A POOL OR SPA Width Length Depth (deep) Depth (shallow) Radius 2 x 3.14 x A.D. x 7.5 = Gallons 12 x 12 x 3.14 x 3.5 x
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More informationBisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -
Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner Users Manual August 5, 2002 A Product By: Bisnet - 1 - DCPP Users Manual Table of Contents CHAPTER 1 PQ 2 4 What is PQ Squared? 4 CHAPTER
More informationTechnical Information for PVX Series Pumps
Technical Information for PVX Series Pumps TM 604 PROGRESS DRIVE, HARTLAND, WI 53029 USA Phone: (262) 367-4299 FAX: (262) 367-5645 URL: www.hartmanncontrols.com E-mail: sales@hartmanncontrols.com PVX pumps
More informationMinimizing Energy Consumption Through Valve Selection
Minimizing Energy Consumption Through Valve Selection www.valmatic.com Copyright 2003 American Water Works Association Presented to 2003 Copyright 2004 Val-Matic Valve and Manufacturing Corporation MINIMIZING
More informationWSB clean: Installation Manual
WSB clean: Installation Manual Models: WSB 400 WSB 1250 WSB 500 WSB 1500 WSB 600 WSB 1600 WSB 750 WSB 1800 WSB 1000 TABLE OF CONTENTS 1 INTRODUCTION...3 2 SAFETY INFORMATION...3 3 WSB CLEAN SYSTEM OPERATION...4
More informationGenerator Efficiency Optimization at Remote Sites
Generator Efficiency Optimization at Remote Sites Alex Creviston Chief Engineer, April 10, 2015 Generator Efficiency Optimization at Remote Sites Summary Remote generation is used extensively to power
More informationSeptember Leopold Sludge Collection Equipment
September 2012 Leopold Sludge Collection Equipment Clari-Trac -2 (CT2 ) Submerged Sludge Collector Arrangement differential head to sludge disposal Graphic on Front of Brochure Illustrates the Principle
More informationCOURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson
What you will learn in this lesson IN THIS LESSON, YOU WILL LEARN... Installation steps for an AdvanTex Treatment System Important inspection points for installation inspection UNIT 4-1 Installation Steps
More informationSAE Baja - Drivetrain
SAE Baja - Drivetrain By Ricardo Inzunza, Brandon Janca, Ryan Worden Team 11A Concept Generation and Selection Document Submitted towards partial fulfillment of the requirements for Mechanical Engineering
More informationHydraulic Power Supply and Motors Concept and Theory
Hydraulic Power Supply and Motors Concept and Theory Graco, Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 1996 Graco Inc. Form No. 321-046 1/96 Rev 2 SL Training 11/14 Hydraulic Systems Component Identification
More informationDrip In PC Pressure Compensating Dripline
Pressure Compensating Dripline Micro-Irrigation A technologically superior and cost effective way to irrigate Difficult topographical conditions Low and varying water pressures Installations requiring
More informationVERIFICATION PROTOCOL FOR PARKING LOT SALT SPREADERS
VERIFICATION PROTOCOL FOR PARKING LOT SALT SPREADERS SALT APPLICATION VERIFIED EQUIPMENT (SAVE) PROGRAM Robert Roszell / Program Director 3/8/2016 www.savesalt.ca Table of Contents Introduction... 2 Purpose
More informationPiping Systems. J. David Bankston, Jr., and Fred Eugene Baker*
SRAC Publication No. 373 December 1994 Piping Systems J. David Bankston, Jr., and Fred Eugene Baker* Whether you are pumping water to fill a pond or to aerate, it pays to do it as economically as possible.
More informationDAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M
DAV-M Air Release and Vacuum Break Valves Product Catalogue DAV - M DAV-M (Metal Air Valves) Edition / DAV Series DAV-M General DAV-Metal Air Release and Vacuum Break Valves First Operation: Venting air
More informationExperiment No.3: Flow through orifice meter. Background and Theory
Experiment No.3: Flow through orifice meter Background and Theory Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters (Head flow meters)
More informationMONOVAR is the energy dissipating valve.
MONOVAR is the energy dissipating valve. Features Extremely simple design (patented) Excellent cavitation characteristics Very accurate flow or pressure control Manual or automatic control Suitable for
More informationCHAPTER 12: OPERATIONS & MAINTENANCE
CHAPTER 12: OPERATIONS & MAINTENANCE Figure 12-1: A combination sewer cleaning truck is used to hydro-flush and vacuum sewer lines. The nozzles and tools used with similar trucks have advanced dramatically
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS
INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance
More information3. The working pressure shall be 145 psi and tested to 230 psi.
Revisions to Section 333313 (standards for ARI) D. Automatic Air Release Valves for Wastewater Systems All force mains shall have automatic air release valves installed as they are indicated on the plans.
More informationSmartCone Differential Pressure Flow Meter User Manual
SmartCone Differential Pressure Flow Meter User Manual Page 1 Table of Contents Section 1 - SmartCone Introduction... 4 1.1 Introduction... 4 1.2 SmartCone - Meter Components... 4 1.3 Principles of Operation...
More informationD-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features
D26.SWG.CAT.ENG0 D-26 Wastewater Combination Air Valve for Wastewater Description The D-26 Combination Air Valve combines an air & vacuum component and an air release component in a single body. The valve
More informationStudying the Positioning Accuracy
Ball Screw Studying the Positioning Accuracy Causes of Error in the Positioning Accuracy Point of Selection Studying the Positioning Accuracy The causes of error in the positioning accuracy include the
More informationSERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX
GORMAN-RUPP AT YOUR SERVICE THE GORMAN-RUPP COMPANY P.O. Box MANSFIELD, OH. 90 9..0 FX 9.. EMAIL GRSALES@GORMANRUPP.COM How To Read Pump Performance Curves The subject of this bulletin covers the reading
More information3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7
W1860BE.book Page 7 Tuesday, January 28, 2003 11:01 PM 3. Fuel System A: GENERAL The fuel pressurized by the fuel tank inside pump is delivered to each fuel injector by way of the fuel pipe and fuel filter.
More informationLINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.
LINE SILENCER Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited. PRODUCT GUIDE PULSCO LINE SILENCER TABLE OF CONTENTS DESCRIPTION PAGE PULSCO LINE
More informationWhite Paper. Phone: Fax: Advance Lifts, Inc. All rights reserved.
White Paper TURNTABLE AppLicATioN GUidE This section covers the full range of turntables manufactured by Advance Lifts. The basic information necessary to select an appropriate turntable for an application
More informationMinimizing Energy Consumption Through Valve Selection
VM MECTVS/WP White Paper Minimizing Energy Consumption Through Valve Selection Table of Contents Introduction.............................. 2 Headloss Calculations...................... 2 Energy Calculations........................
More informationTest Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.
Test 1 1. Which statement is True? A. Pneumatic systems are more suitable than hydraulic systems to drive powerful machines. B. Mechanical systems transfer energy for longer distances than hydraulic systems.
More informationApplication of DSS to Evaluate Performance of Work Equipment of Wheel Loader with Parallel Linkage
Technical Papers Toru Shiina Hirotaka Takahashi The wheel loader with parallel linkage has one remarkable advantage. Namely, it offers a high degree of parallelism to its front attachment. Loaders of this
More informationAs diesel fuel ages it degrades in 2 ways: particulate formation, and biological growth.
ESS.WP.534.YQA Fuel Quality and Polishing Your Questions Answered (20) Fuel Quality and Polishing earth safe Fuel Systems for Critical Power 18.1 Why is filtration / polishing needed? Filtration / Polishing
More informationBurn Characteristics of Visco Fuse
Originally appeared in Pyrotechnics Guild International Bulletin, No. 75 (1991). Burn Characteristics of Visco Fuse by K.L. and B.J. Kosanke From time to time there is speculation regarding the performance
More informationHydraulics Guide. Table 1: Conveyance Factors (English Units)... 7 Table 2: Conveyance Factors (Metric Units)... 8
Table of Contents 1.1 Index of Tables... 1 1.2 Index of Figures... 1 1.3 Overview of Hydraulic Considerations... 2 1.4 Discharge Curves... 2 1.5 Conveyance Method... 5 1.6 Flow Velocity Considerations...
More informationSeries 34. Specifications
Series Air Release Valves Stainless Steel T Trim Standard Stainless Steel Floats Guaranteed Easily Serviced Without Removal From Pipeline Working Pressures to 800 PSI Engineered For Drip Tight Seal At
More informationBRAKE SYSTEM DESIGN AND THEORY
RAKE SYSTEM DESIGN AND THEORY Aircraft brake systems perform multiple functions. They must be able to hold the aircraft back at full static engine run-up, provide adequate control during ground taxi operations,
More informationT205VB Series Tank Blanketing Vacuum Breakers
February 2014 T205VB Series Tank Blanketing Vacuum Breakers Figure 1. Typical T205VB Series Vacuum Breaker Introduction The T205VB Series vacuum breakers (Figure 1) are used for precise control of small
More informationECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
More informationOperation and Maintenance
E-Z Set Company requires regular inspection and maintenance of the E-Z Treat Re- Circulating Sand/Media Filter, as a condition of purchase and ongoing operation compliance. The mandatory service contract
More informationBERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
More informationOptimizing Plane Performance by Finding the Right Prop 10/15/09
Optimizing Plane Performance by Finding the Right Prop 10/15/09 This is not an article for the meek or timid. Finding the right prop for your engine and airframe the engine is mounted on can be a daunting
More informationModule 6. Actuators. Version 2 EE IIT, Kharagpur 1
Module 6 Actuators Version 2 EE IIT, Kharagpur 1 Lesson 25 Control Valves Version 2 EE IIT, Kharagpur 2 Instructional Objectives At the end of this lesson, the student should be able to: Explain the basic
More information1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A
Worldwide Contacts www.tyco-fire.com DV-5 Deluge Valve Diaphragm Style General Description The TYCO 1-1/2 inch to inch (DN40 to DN200), DV-5 Deluge Valves are diaphragm type valves designed for vertical
More information(3) (4) (6) (5) (10) (9) (8) (7)
3. Fuel System A: GENERAL The fuel pressurized by the fuel tank inside pump is delivered to each fuel injector by way of the fuel pipe and fuel filter. Fuel injection pressure is regulated to an optimum
More informationTABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology
1 2 TABLE OF CONTENTS Service Information... 2 Quick Start Instructions... 4-5 Introduction... 6 Specifications... 6 Controls and Terminology... 7 Transducer Mounting Locations... 8 Mounting the Transducer...
More informationDECONTAMINATE BY PRIORITY Items such as wheeled vehicles, forklifts, and railcars, which are critical to the site s overall mission, will need to rece
CHAPTER 5 DECONTAMINATION The idea behind decontamination is relatively the same for a fixed site as for a tactical unit. Personnel need to decontaminate to reduce the hazard and spread of a contaminating
More informationInstallation Suggestions
Installation Suggestions P/N 52200-98 Suggestions For Installing The Balboa 05-28-14 Introduction The Balboa consists of a controller that opens and closes valves that supply water to four groups of jets.
More informationWhole NEW Class. Introducing a. of Car Wash! Welcome to a whole new class of car wash representing a technological advancement and
Introducing a Whole NEW Class of Car Wash! OASIS CAR WASH SYSTEMS Welcome to a whole new class of car wash representing a technological advancement and bringing an all new eco-friendly product to the car
More informationCOMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report R0. By Kimbal A.
COMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report 412509-1R0 By Kimbal A. Hall, PE Submitted to: WESTFALL MANUFACTURING COMPANY May 2012 ALDEN RESEARCH
More informationType HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications
Bulletin 71.1 D103087X012 Type HSR December 2017 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications High Capacity Compact Design P1524_1 High Capacity Internal
More informationCrispin Valves Operating Guide. Crispin
Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com
More informationOriginal. M. Pang-Ngam 1, N. Soponpongpipat 1. Keywords: Optimum pipe diameter, Total cost, Engineering economic
Original On the Optimum Pipe Diameter of Water Pumping System by Using Engineering Economic Approach in Case of Being the Installer for Consuming Water M. Pang-Ngam 1, N. Soponpongpipat 1 Abstract The
More informationCONCEPTUAL UTILITY REPORT FOR THE CANYONS PHASE 1 CITY OF CASTLE PINES, CO
CONCEPTUAL UTILITY REPORT FOR THE CANYONS PHASE 1 CITY OF CASTLE PINES, CO PREPARED FOR: SHEA HOMES 9380 STATION ST., SUITE 600 LONE TREE, CO 80124 PHONE: 303-791-8180 CONTACT: RYAN MCDERMED PREPARED BY:
More informationFUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc.
FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS by John Michalak Romet International, Inc. INTRODUCTION Rotary gas meters have been in use for over sixty years in the natural gas distribution industry. Over
More informationAtomizer 36-DC User Guide
TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide SERVICE CASE HUMIDIFICATION Specification Sheet... 2 Installation Guide... 3 Layout Diagram... 4 Maintenance Guide... 5 Wiring Diagram... 6 Pull Sheet...
More information2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways
2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways Absolute Control. Optimized Efficiency. Features and Installation Self-cleaning: No filters
More informationPROGRESSIVE CUSHIONING FOR HYDRAULIC CYLINDERS Michael Hanley Electro Hydraulic Machinery Co.
HEAVY MOVABLE STRUCTURES, INC. FOURTEENTH BIENNIAL SYMPOSIUM October 22 25, 2012 PROGRESSIVE CUSHIONING FOR HYDRAULIC CYLINDERS Michael Hanley Electro Hydraulic Machinery Co. www.ehmcompany.com CARIBE
More informationThe Stream Engine. Personal Hydropower. Owner s Manual PLEASE READ CAREFULLY. Made in Canada
The Stream Engine Personal Hydropower Owner s Manual PLEASE READ CAREFULLY Made in Canada by Energy Systems and Design Ltd. PO Box 4557 Sussex NB Canada E4E 5L7 Phone +1 (506) 433-3151 Fax +1 (506) 433-6151
More informationTHS SERIES FILTER BUTTERFLY VALVE STYLE FACE PIPING
THS SERIES FILTER BUTTERFLY VALVE STYLE FACE PIPING INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS TABLE OF CONTENTS 1.0 PRINCIPALS
More informationTargeted Application of STATCOM Technology in the Distribution Zone
Targeted Application of STATCOM Technology in the Distribution Zone Christopher J. Lee Senior Power Controls Design Engineer Electrical Distribution Division Mitsubishi Electric Power Products Electric
More information