Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC

Size: px
Start display at page:

Download "Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC"

Transcription

1 -148 March 008 Accessories Auxiliary Contacts Side-Mount Auxiliary Contacts Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can be combined with XTPAXSATR and XTPAXFA trip indicating auxiliary contact. Table Side-Mount Auxiliary Contacts Contact Configuration Contact Sequence Screw Terminals Spring Cage Terminals 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC11 L1 L L3 XTPAXSA NO-NC 5 XTPAXSA1 NO-1NC 5 XTPAXSA1 L1 L L3 XTPAXSA1 Front-Mount Auxiliary Contacts L1 L L3 XTPAXSA Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT). 45 mm (XTPR B and XTPB) or 55 mm (XTPR D) widths of manual motor protectors remain unchanged. Table Front-Mount Auxiliary Contacts Contact Configuration Contact Sequence Screw Terminals Spring Cage Terminals 1NO-1NC 5 XTPAXFA11 L1 L L3 XTPAXFA11 1NO-0NC 5 XTPAXFA 5 XTPAXFAC L1 L L3 XTPAXFA 0NO-1NC 5 XTPAXFAC L1 L L3 XTPAXFAC Discount Symbol CD7 CA08001E

2 March Side-Mount Trip Indicating Auxiliary Contacts Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General Trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable. Table Side-Mount Trip Indicating Auxiliary Contacts Contact Configuration Contact Sequence x 1NO XTPB, XTPR, XTPM, XTPT XTPAXSATR On/Off L1LL3 + > Trip + L1LL3 + > x 1NC XTPB, XTPR, XTPM, XTPT XTPAXSATR On/Off L1LL3 + > Trip + L1LL3 + > Early-Make Front-Mount Auxiliary Contacts XTPBXFAEM0 XTPAXFAEM0 For use with XTPB, B-Frame XTPR and XTPT. Can be fitted to the front of a manual motor protector. 45 mm width of manual motor protector remains unchanged. For early energization of undervoltage release, e.g. in Emergency-Stop circuits to EN Table Early-Make Front-Mount Auxiliary Contacts Contact Configuration Contact Sequence NO 5 XTPB XTPBXFAEM NO XTPR, XTPM, XTPT XTPAXFAEM Not for use with rotary handle mechanism. Discount Symbol CD7 CA08001E

3 -150 March 008 Shunt Release C1 Current Limiter Contact Sequence Can be used to trip the manual motor protector from a remote location. Can be fitted on the left side of manual motor protectors. Cannot be combined with the XTPAXUVR. DC: Intermittent operation 5 sec. Table Shunt Release Screw Terminals XTPAXSR4V50H XTPAXSR48V50H XTPAXSR1V50H XTPAXSRV60H XTPAXSR08V60H XTPAXSR0V50H XTPAXSR30V50H XTPAXSR40V50H XTPAXSR40V60H XTPAXSR380V50H XTPAXSR400V50H XTPAXSR415V50H XTPAXSR440V60H XTPAXSR480V60H XTPAXSR4VDC XTPAXSR48VDC XTPAXSR60VDC XTPAXSR1VDC XTPAXSR15VDC XTPAXSR0VDC XTPAXSR50VDC Undervoltage Release Spring Cage Terminals XTPAXSRC30V50H XTPAXSRC4VDC Can be used to trip the manual motor protector from a remote location. Can be fitted on left side manual motor protectors. Cannot be combined with XTPAXSR. When combined with a circuit breaker, it can be used as Emergency- Stop device to IEC/EN Table Undervoltage Release Screw Terminals XTPAXUVR4V50H XTPAXUVR4V60H XTPAXUVR48V50H XTPAXUVR60V50H XTPAXUVR1V50H XTPAXUVRV60H XTPAXUVR08V60H XTPAXUVR0V50H XTPAXUVR30V50H XTPAXUVR40V50H XTPAXUVR40V60H XTPAXUVR380V50H XTPAXUVR400V50H XTPAXUVR415V50H XTPAXUVR440V60H XTPAXUVR480V60H XTPAXUVR600V60H Spring Cage Terminals XTPAXUVRC30V50H C D1 U D Contact Sequence The enhances the switching capacity of the XT manual motor protectors. It can be used with the XTPB, XTPR...BC1, XTPR...DC1 for individual or group protections. The rated uninterrupted current is 63A for IEC and 5A for UL/CSA. It can be mounted next to or behind the manual motor protector. See Tables -17 and -18 for ratings when using the current limiter. Table Current Limiter Contact Sequence To enhance the switching capacity of non- L 1 inherently safe 5A Manual Motor Protectors to 150 ka/ T 440V Max. rated operation voltage Ue = 690V, rated uninterrupted current I u = 63A. Can be used for individual and group protection. For group protection and in combination with the XTPR D, order additional XTPAXIT incoming terminal if required. Mounting next to or behind the manual motor protector A XTPR...D: 0 ka/400v, ka/690v. Lockable Rotary Handle Table Replacement Lockable Rotary Handle Lockable Rotary Handle that mounts 5 XTPAXLRH directly to the XTPR manual motor protectors. Comes standard with XTPR. U.S. $ Discount Symbol CD7 CA08001E

4 March Rotary Handle Mechanism Table Rotary Handle Mechanism Complete Kits Includes Handle, Shaft, and Required Hardware Separate Parts Rotary Handle Mech Black For use on main switches to IEC/EN Rotary Handle Mech Red/Yellow For use on main switch with Emergency-Stop function to IEC/EN Rotary Handle Mech Black For use on main switches to IEC/EN 6004 where XTPR is mounted 90 from vertical. Rotary Handle Mech Red/Yellow For use on main switch with Emergency-Stop function to IEC/EN 6004 where XTPR is mounted 90 from vertical. Rotary Handle Only Black For use on main switches to IEC/EN Rotary Handle Only Red/Yellow For use on main switch with Emergency-Stop function to IEC/EN Rotary Handle Only Black For use on main switches to IEC/EN 6004 where XTPR is mounted 90 from vertical. Rotary Handle Only Red/Yellow For use on main switch with Emergency-Stop function to IEC/EN 6004 where XTPR is mounted 90 from vertical. 1 XTPAXRHMB 1 XTPAXRHMRY 1 XTPAXRHM90B 1 XTPAXRHM90RY XTPAXRHB XTPAXRHRY XTPAXRH90B XTPAXRH90RY Shaft Only Includes Shaft to mount to XTPR, 175 mm length. XTPAXRHMSFT Shaft Only Includes Shaft to mount to XTPR, 7 mm length, minimum 50 pcs. Bulk Pack. Shaft Only Includes Shaft to mount to XTPR, 98 mm length, minimum 50 pcs. Bulk Pack. 50 XTPAXRHMSFTB7 50 XTPAXRHMSFTB98 Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of 0 40 mm. Carrier with extension shaft included. With ON/OFF switch position and + (tripped), lockable with 3 padlocks, 4 8 mm hasp. Can be locked in the ON position, if required. Rotary Handle Mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock. Not for use with XTPAXFAEM0 early-make front mount auxiliary contact. Sealing Facility Table -19. Sealing Facility To prevent tampering with the overload release and the test function. It can be sealed using industry standard sealing wire. For use with XTPR manual motor protectors. 5 XTPAXSW Discount Symbol CD7 CA08001E

5 -15 March 008 Three-Phase Commoning Links Frame B Frame D For parallel power feed to several manual motor protectors on terminals 1, 3 and 5. Table Three-Phase Commoning Links Frame B MMP with no side mounted auxiliaries or voltage releases MMP Length of Link (mm) Unit Width (mm) KA KA KA KA5 Each MMP with one auxiliary contact or trip-indicating auxiliary contact fitted on the right KB KB KB KB5 Frame D Each MMP with an auxiliary contact and trip-indicating auxiliary contact mounted on the right or a voltage release mounted on the left. MMP with no side mounted auxiliaries or voltage releases KC KC KAD KA3D KA4D Each MMP with one auxiliary contact or trip-indicating auxiliary contact fitted on the right KBD KB3D KB4D Each MMP with an auxiliary contact or trip-indicating auxiliary contact mounted on the right or a voltage release mounted on the left KCD KC4D Protected against accidental contact. B-Frame short circuit proof Ue = 690V, Iu = 63A; D-Frame short circuit proof Ue = 690V, Iu = 18A. Frame B links can be combined by rotating mounting. Frame D links cannot be combined. Discount Symbol CD7 CA08001E

6 March Shroud for Unused Commoning Link Terminals Table Shroud for Unused Terminals of Three-Phase Commoning Links B-Frame XTPR D-Frame XTPR To cover unused terminals on three-phase commoning link. Protected against direct contact. 0 XTPAXUTS XTPAXUTSD Incoming Terminal for Three-Phase Commoning Link Table Incoming Terminal B-Frame XTPR, XTPB 5 XTPAXIT For three-phase commoning link, protected against accidental contact, Ue = 690V, Iu = 63A; For conductor cross-sections:.5 5 mm stranded;.5 16 mm flexible with ferrules, AWG Line-Side Adapter Table Line-Side Adapter B-Frame XTPR to create a UL 508 Type E/F Manual Combination Starter 5 XTPAXLSA D-Frame XTPR to create a UL 508 Type E/F Manual Combination Starter 1 XTPAXLSAD XTPAXLSA is for three-phase commoning link, finger- and back-of-hand proof, Ue = 690V, Iu = 60A for conductor cross sections:.5 5 mm stranded,.5 16 mm flexible with ferrule, AWG XTPAXLSAD cannot be combined with three-phase commoning links. Discount Symbol CD7 CA08001E

7 -154 March 008 Combination Connection Kits Table Combination Connection Kits Non-reversing Starters XTPR...B + XTCE...B Mechanical connection element for XTPR...B and contactor Main current wiring between XTPR...B and contactor in tool-less plug connection Cable guidance Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. 6 cables up to.5 mm external diameter or 4 cables up to 3.5 mm external diameter. Std. Pack 1 XTPAXTPCB XTPR...B + XTCE...C 1 XTPAXTPCC XTPR...D + XTCE...D DIN rail adapter plate 1 XTPAXTPCD Main current wiring between XTPR and contactor U.S. $ Reversing Starters XTPR...B + XTCE...B01_ XTPR...B + XTCE...C Mechanical connection element for XTPR...B and contactor Reversing starter main current wiring in tool-less plug connection Control cables for electrical interlocking in toolless plug connection: K1M: A1 KM: 1 K1M: 1 KM: A1 K1M: A KM: A Cable guidance Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. 6 cables up to.5 mm external diameter or 4 cables up to 3.5 mm external diameter. DIN rail adapter plate Reversing starter main current wiring 1 XTPAXTPCRB 1 XTPAXTPCRC Star-Delta Starter Sets XTPR...B + XTCE...B DIN rail adapter plate Main current wiring between XTPR...B and contactor Electrical interlock between delta and star contactor Use as contactor auxiliary switch XTCEXFAT_ 1 XTPAXSDSB XTPR...B + XTCE...C DIN rail adapter plate Main current wiring between XTPR...B and contactor 1 XTPAXSDSC Discount Symbol CD7 CA08001E

8 March Combination Connection Kits Table Combination Connection Kits (Continued) Electrical Connection Module DIN Rail Adapter Plates XTPR...B + XTCE...C XTPR...D + XTCE...D XTPAXTPCB XTPAXTPCRB Main current wiring between XTPR...B and contactor Use only in combination with busbar adapter Main current wiring between XTPR...D and contactor Use only in combination with busbar adapter 45 mm wide adapter plate with one DIN rail Connection element for side-by-side positioning of further plates Std. Pack 5 XTPAXECMC 5 XTPAXECMD 4 XTPAXTPCPB XTPR...B + XTCE...C XTPAXECMC 45 mm wide adapter plate with two DIN rails Connection element for side-by-side positioning of further plates 4 XTPAXTPCRPB XTPAXECMD XTPR...D + XTCE...C XTPR...D + XTCE...D 55 mm wide adapter plate with two DIN rails Connection cams for further plates For use with reversing and star-delta starters 4 XTPAXTPCPD Lateral Module Connection Element Can be grouped on the DIN rail adapter Expansion of the mounting width by 9 mm XTPAXLM For connection of several DIN rail adapters 50 XTPAXCNE Discount Symbol CD7 CA08001E

9 -156 March 008 Pushbutton MMP Enclosures B-Frame Table Insulated Enclosures for Surface Mounting of XTPB Pushbutton Motor-Protective Circuit Breakers Global Usage IP40 1 XTPB MMP Only or with: XTPAXFA, XTPBXFAEM0, XTPAXSA..., XTPAXUVR..., XTPAXSR... XTPBXENCS x 80 x [6. x 3.15 x 4.59] 3R, 4X, 1, 13 With actuation membrane. XTPBXENCS x 80 x [6. x 3.15 x 4.59] 3R, 4X, 1, 13 3R, 4X, 1, 13 3R, 4X, 1, 13 3R, 4X, 1, 13 XTPB MMP Only or with: XTPAXFA, XTPAXUVR, XTPAXSR, XTPB MMP Only or with: XTPAXFA, XTPBXFAEM0, XTPAXUVR..., XTPAXSR, Integrated terminal for PE(N) connection, two M5 cable entry knockouts at top and at bottom. Lockable in OFF position. XTPBXENCSLO x 80 x 19.5 [6. x 3.15 x 5.] Lockable in OFF position in combination with XTPBXFAEM0 Early Make front mount auxiliary contact With Emergency-Stop (E-Stop) pushbutton actuator, Red-Yellow With Emergency-Stop (E-Stop) pushbutton actuator, Red-Yellow key release XTPBXENCSLE x 80 x 19.5 [6. x 3.15 x 5.] XTPBXENCSES x 80 x 177. [6. x 3.15 x 6.98] XTPBXENCSEK x 80 x 177. [6. x 3.15 x 6.98] Table Insulated Enclosures for Surface Mounting of XTPB Pushbutton North American Usage IP41 1 XTPB MMP Only or with: XTPAXFA, XTPBXFAEM0, XTPAXSA..., XTPAXUVR..., XTPAXSR, XTPBXENAS x 80 x [6. x 3.15 x 4.59] 3R, 4X, 1, 13 With actuating diaphragm XTPBXENAS x 80 x [6. x 3.15 x 4.59] 3R, 4X, 1, 13 3R, 4X, 1, 13 3R, 4X, 1, 13 3R, 4X, 1, 13 XTPB MMP Only or with: XTPAXFA, XTPAXUVR, XTPAXSR, XTPB MMP Only or with: XTPAXFA, XTPBXFAEM0, XTPAXUVR..., XTPAXSR, Built-in terminal for PE(N). North American enclosures come with conduit adapters for use with 1/" NPT. Lockable in OFF position XTPBXENASLO x 80 x 19.5 [6. x 3.15 x 5.] Lockable in OFF position in combination with XTPBXFAEM0 Early Make front mount auxiliary contact. With Emergency-Stop (E-Stop) pushbutton actuator, Red-Yellow With Emergency-Stop (E-Stop) pushbutton actuator, Red-Yellow key release XTPBXENASLE x 80 x 19.5 [6. x 3.15 x 5.] XTPBXENASES x 80 x 177. [6. x 3.15 x 6.98] XTPBXENASEK x 80 x 177. [6. x 3.15 x 6.98] Dimensions Page -168 Discount Symbol CD7 CA08001E

10 March Table -00. Insulated Enclosures for Flush Mounting of XTPB Pushbutton Global and North American Usage Front IP40 1 Front 3R, 4X, 1, 13 XTPB Only or with: XTPAXFA, XTPBXFAEM0, XTPAXSA, XTPAXUVR, XTPAXSR, XTPBXENCF40 19 x 90. x 115. [5.08 x 3.55 x 4.54] With actuation membrane XTPBXENCF55 19 x 90. x 115. [5.08 x 3.55 x 4.54] Front 3R, 4X, 1, 13 Front 3R, 4X, 1, 13 Front 3R, 4X, 1, 13 Front 3R, 4X, 1, 13 Integrated terminal for PE(N) connection. Rotary MMP Enclosures XTPB Only or with: XTPAXFA, XTPAXUVR, XTPAXSR, XTPB Only or with: XTPAXFA, XTPBXFAEM0, XTPAXUVR, XTPAXSR, Lockable in OFF position XTPBXENCFLO55 19 x 90. x 115. [5.08 x 3.55 x 4.54] Lockable in OFF position in combination with XTPBXFAEM0 Early Make front mount auxiliary contact With Emergency-Stop (E-Stop) pushbutton actuator With Emergency-Stop (E-Stop) pushbutton actuator, key release XTPBXENCFLE55 19 x 90. x 115. [5.08 x 3.55 x 4.54] XTPBXENCFES55 19 x 90. x [5.08 x 3.55 x 6.93] XTPBXENCFEK55 19 x 90. x [5.08 x 3.55 x 6.93] B-Frame D-Frame Table -01. Insulated Enclosures for Surface Mounting of B-Frame (0.1 3A) XTPR Rotary Motor-Protective Circuit Breakers Global Usage IP41 with vertical mounting B-Frame XTPR Only or with: XTPAXFA, XTPAXSA, XTPAXSATR, XTPAXUVR, XTPAXSR, Cover with aperture dimensioned to accommodate front of MMP. IP40, when mounted turned through 90 to left/right XTPAXENCS x 0 x 4 [6.30 x 3.94 x 4.09] With black/grey rotary handle XTPAXENCS65B 160 x 0 x 130 [6.30 x 3.94 x 5.1] IP40 B-Frame XTPR Only or with: XTPAXSA, XTPAXUVR, XTPAXSR, With red/yellow rotary handle for use as Emergency-Stop switches to IEC/ EN 6004 Cover with aperture dimensioned to accommodate front of MMP. XTPAXENCS65RY 160 x 0 x 130 [6.30 x 3.94 x 5.1] XTPAXENCS x 80 x 0 [6. x 3.15 x 3.94] IP55 IP55 B-Frame XTPR Only or with: XTPAXFA, XTPAXSA, XTPAXUVR, XTPAXSR, With black/gray rotary handle XTPAXENCS55B 158 x 80 x 15.5 [6. x 3.15 x 4.94] With red/yellow rotary handle for use as Emergency-Stop switches to IEC/ EN 6004 XTPAXENCS55RY 158 x 80 x 15.5 [6. x 3.15 x 4.94] M5 metric cable entry knock-out, top and bottom. Cable push-through membrane, top and bottom, in the back plate and as a control line entry. Includes N and PE terminals. Integrated terminal for PE(N) connection, two M5 cable entry knockouts at the top and bottom. Discount Symbol CD7 CA08001E

11 -158 March 008 Table -0. Insulated Enclosures for Surface Mounting of B-Frame (0.1 3A) XTPR Rotary North American Usage IP55 1, 1, 3R B-Frame XTPR Only or with: XTPAXSA and XTPAXFA, XTPAXUVR and XTPAXFA, XTPAXSR and XTPAXFA, Built-in N and PE terminal, lower part without knockouts. With black/gray rotary handle XTPAXENAS55B 160 x 0 x 130 [6.30 x 3.94 x 5.1] With red/yellow rotary handle for use as Emergency-Stop switch to VDE 0113 XTPAXENAS55RY 160 x 0 x 130 [6.30 x 3.94 x 5.1] Table -03. Insulated Enclosures for Surface Mounting of B-Frame XTPR (0.1 3A) Rotary Motor-Protective Circuit Breakers with XTPAXFAEM0 Early-Make Front Mount Auxiliary Contact Global Usage IP55 IP55 Table -04. Insulated Enclosures for Surface Mounting of B-Frame XTPR (0.1 3A) Rotary with XTPAXFAEM0 Early- Make Front Mount Auxiliary Contact North American Usage IP55 1, 1, 3R Built-in N and PE terminal, lower part without knockouts. Table -05. Insulated Enclosures for Flush Mounting of B-Frame (0.1 3A) XTPR Rotary Global Usage Front IP40 B-Frame XTPR and XTPAXFAEM0 only or with: XTPAXFA, XTPAXSA, XTPAXSATR, XTPAXUVR, XTPAXSR, B-Frame XTPR and XTPAXFAEM0 only or with: XTPAXFA, XTPAXUVR, XTPAXSR, B-Frame XTPR Only or with: XTPAXSA, XTPAXUVR, B-Frame XTPR Only or with: XTPAXSA, XTPAXUVR, XTPAXSR, With black/gray rotary handle XTPAXENCSEM65B 160 x 0 x 130 [6.30 x 3.94 x 5.1] With red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 6004 XTPAXENCSEM65RY 160 x 0 x 130 [6.30 x 3.94 x 5.1] With black/gray rotary handle XTPAXENCSEM55B 158 x 80 x 0 [6. x 3.15 x 3.94] With red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 6004 XTPAXENCSEM55RY 158 x 80 x 0 [6. x 3.15 x 3.94] With black/grey rotary handle XTPAXENASEM55B 160 x 0 x 130 [6.30 x 3.94 x 5.1] With red/yellow rotary handle for use as Emergency-Stop switch to VDE 0113 Cover with aperture dimensioned to accommodate front of MMP. XTPAXENASEM55RY 160 x 0 x 130 [6.30 x 3.94 x 5.1] XTPAXENCF40 19 x 85 x 96 [5.08 x 3.35 x 3.78] Front IP55 B-Frame XTPR Only or with: XTPAXSA, XTPAXUVR, XTPAXSR, XTPAXFA, Integrated terminal for PE(N) connection. With black/gray rotary handle XTPAXENCF55B 19 x 85 x 14 [5.08 x 3.35 x 4.88] With red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 6004 XTPAXENCF55RY 19 x 85 x 14 [5.08 x 3.35 x 4.88] Table -06. Insulated Enclosures for Surface Mounting of D-Frame ( 65A) Rotary Motor-Protective Circuit Breakers 1, 1, 3R 1, 1, 3R D-Frame XTPR Only or with: XTPAXFA, XTPAXFAEM0, XTPAXSA, XTPAXSATR, XTPAXUVR, XTPAXSR, With black/gray rotary handle XTPAXENCSD65B 40 x 160 x 197 [9.45 x 6.30 x 7.76] With red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 6004 XTPAXENCSD65RY 40 x 160 x 197 [9.45 x 6.30 x 7.76] Integrated terminal for PE(N) connection. Metric knockouts: Top bottom: M5/M3 In backplate: M5/M3 Control cable entry: M0 Discount Symbol CD7 CA08001E

12 March MMP Enclosure Accessories Table -07. XTPR Manual Motor Protector Enclosure Padlock Attachment XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY, XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY XTPAXENCSD65B, XTPAXENCSD65RY XTPAXENCF55B, XTPAXENCF55RY Lockable in the 0-position of the XTPR manual motor protector. Lockable in the OFF position of the B-Frame XTPR manual motor protector. Table -08. Neutral Terminal for use with XTPB and B-Frame XTPR Flush-Mount Enclosures XTPBXENCF40, XTPBXENCF55, XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY Padlocking feature. Up to 3 padlocks with 3 6 mm hasp thickness. For use as main switch to IEC/EN XTPAXPL1 1 XTPAXPL 3 XTPAXPL3 For connection of a fifth conductor 0 XTPAXNT Metric Cable Glands to EN 506 Indicating Lights with Neon Bulb With locknut and internal strain relief IP68 up to 5 bar, hydrogen free Table -09. Metric Cable Glands 0.5 mm Metric Cable Gland 0 XTPAXMCG mm Wire 5.5 mm Metric Cable Gland 0 XTPAXMCG mm Wire 3.5 mm Metric Cable Gland XTPAXMCG mm Wire 3.5 mm Metric Cable Gland XTPAXMCG3G 18 5 mm wire Metric Diaphragm Grommet For use with XTPR and XTPB enclosures Lights do not carry individual IP or rating. All enclosure ratings remain valid when using indicating lights. Table -11. Indicating Lights Color Indicating Light White Green Red 1 30V 30 40V V 1 30V 30 40V V 1 30V 30 40V V XTPAXILWB XTPAXILWN XTPAXILWC XTPAXILGB XTPAXILGN XTPAXILGC XTPAXILRB XTPAXILRN XTPAXILRC With internal push-through diaphragm Table -. Metric Diaphragm Grommet 0.5 mm Diaphragm Grommet 0 XTPAXMDG mm Wire 5.5 mm Diaphragm Grommet 0 XTPAXMDG mm Wire 3.5 mm Diaphragm Grommet 0 XTPAXMDG3 1 4 mm Wire With integral push-through diaphragm. Discount Symbol CD7 CA08001E

13 -160 March 008 Technical Data and Specifications Table -1. XT Technical Data and Specifications XTPBP16B XTPB016B XTPRP16B XTPR03B XTPR016D XTPR063D XTPMP16B XTPM03B General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C. No. 14 Climatic proofing Damp heat, constant, to IEC ; damp heat, cyclic, to IEC Ambient temperature, C Storage Open Enclosed Mounting position -5 / 80-5 / 55-5 / / 80-5 / 55-5 / / 70-5 / 55-5 / 40-5 / 80-5 / 55-5 / 40 XTPTP16B XTPT05B -5 / 80-5 / 55-5 / Direction of incoming supply As required As required As required As required As required protection Device Terminals against direct contact Shock resistance half-sinusoidal shock ms to IEC (g) IP0 IP00 IP0 IP00 IP0 IP00 IP0 IP00 Finger- and back-of-hand proof Altitude (m), maximum Terminal capacity Solid (mm) Flexible with ferrule to DIN 468, (mm) Solid or stranded (AWG) x (1 6) x (1 6) 18 x (1 6) x (1 6) 18 1 x (1 50) x (1 35) 1 x (1 35) x (1 35) 14 x (1 6) x (1 6) 18 Terminal screw tightening torque Main cable, Nm Main cable, lb-in Control circuit cable, Nm Control circuit cable, lb-in Main contacts Rated impulse withstand voltage (U imp ), V AC Overvoltage category / pollution degree III / 3 III / 3 III / 3 III / 3 III / 3 Rated operational voltage (U e ), V AC Rated uninterrupted current = rated operational current (I u = I e ) in amperes 5 or current setting of the overcurrent release 3 or current setting of the overcurrent release 63 or current setting of the overcurrent release 3 or current setting of the overcurrent release IP0 IP00 x (1 6) x (1 6) 18 Rated frequency, Hz Current heat loss (3-pole at operating temperature), W Lifespan, mechanical (ops) 50,000 0,000 30,000 0,000 0,000 Lifespan, electrical (AC-3 at 400 V) (ops) 50,000 0,000 30,000 0,000 0,000 Maximum operating frequency, operations/hr Short-circuit rating AC See Page DC (ka) (up to XTPR016B) 40 (XTPR00B XTPR03B) Motor switching capacity AC-3 (up to 690 V) in amperes DC-5 (up to 50 V) in amperes (3 contacts in series) (up to XTPM016B) 40 (XTPM00B XTPR03B) (3 contacts in series) or current setting of the overcurrent release 60 (up to XTPT016B) 40 (XTPT00B XTPT05B) CA08001E

14 -33 MMPs & Manual and Combination Motor Controllers Type A30 March 008 Accessories Table Accessories A30 U.S. $ Enclosure, Nonmetallic IP41 General Purpose IP55 Dust and Water Conversion Kit (Converts IP41 Enclosure to IP55) C799MP41 C799MP55 C30MSG1 Conduit Adapter To convert PG16 Metric Threads on C799MP41 and C799MP55 to 1/" N.P.T. Threads C30MSA1 Enclosure, Semimetallic UL Listed for 1, 4, 4X, 1 and 13 Applications C799MP11 Enclosure with Emergency Pushbutton and Indicating Light Flush Plate (Cavity Mount), Nonmetallic IP41 General Purpose IP55 Dust and Water Conversion Kit (Converts IP41 Flush Plate to IP55) C799FP41 C799FP55 C30MSG Emergency Pushbutton For Enclosures and Flush Plates E Button E Button Latch Pull to Release C30MSE1 C30MSE Padlock Attachment For Enclosures and Flush Plates C30MSD Enclosure with Padlock Attachment and Indicating Light Red Indicating Light 1/V 0/40V 380/415V 40/500V 500/600V Green Indicating Light 1/V 0/40V 380/415V 40/500V 500/600V Auxiliary Contacts, Side Mounted 1NO-1NC NO 1NO-1NC Early Closing NO Early Closing SPDT Logic Level (0 ma, 30V maximum) C30MSL1A C30MSL1B C30MSL1L C30MSL1C C30MSL1D C30MSLA C30MSLB C30MSLL C30MSLC C30MSLD C30MSC3 C30MSC4 C30MSC6 C30MSC7 C30MSC3L A30 MMP with Side Auxiliary Contact Discount Symbol CD-1 CA08001E

IEC Contactors & Starters XT IEC Power Control

IEC Contactors & Starters XT IEC Power Control July 008-9 Contents Description Page umber Selection................ - Product Selection.......... - Accessories............... -8 Technical Data and Specifications............ -0 Dimensions...............

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Motor protective circuit breakers

Motor protective circuit breakers Motor protective circuit breakers Motor protective circuit breakers MSP Description The MSP0, MSP1 motor starter protectors are compact motor starter protectors for currents up to 52 A which operate according

More information

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany Makecontact,CageClamp,Front Partno. M22-CK10 Articleno. 216384 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction

More information

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20

More information

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany Break,CageClamp,Front Partno. M22-CK01 Articleno. 216385 CatalogNo. M22-CK01Q Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA,

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

Motor protective circuit breakers

Motor protective circuit breakers Motor protective circuit breakers Motor protective circuit breakers MPE 25 Rated current 0,16-32 A Example of MPE configuration: Advantages With overload and short circuit protection Fixed short circuit

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm) Contactelement,1N/C,frontmount,6.contact,screwconnection Partno. M22-K01 Articleno. 216378 CatalogNo. M22-K01Q Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection Deliveryprogramme Overloadrelay,24-40A,1N/O+1N/C Partno. ZB65-40 Articleno. 278458 CatalogNo. XTOB040DC1 Product range Overload relay ZB up to 150 A Frame size ZB65 Phase-failure sensitivity IEC/EN 60947,

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Motor Circuit Breakers C3

Motor Circuit Breakers C3 Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Overloadrelay,10-16A,1N/O+1N/C. Articleno Overloadrelay,10-16A,1N/O+1N/C Partno. ZB32-16 Articleno. 278452 CatalogNo. XTOB016CC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Product range Accessories Accessories Overload relays

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection Deliveryprogramme Overloadrelay,6-9A,1N/O+1N/C Partno. ZE-9 Articleno. 014708 CatalogNo. XTOM009AC1 Product range ZE overload relays for mini contactor relays Phase-failure sensitivity IEC/EN 60947, VDE

More information

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES DESIGN FEATURES Double break contacts Polycarbonate shroud for wired terminal protection included Excellent switching & high short circuit capacity Compact and reliable Easy installation Front, rear and

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

Flexible. Intelligent. Trendsetting.

Flexible. Intelligent. Trendsetting. www.eaton.com www.moeller.net Flexible. Intelligent. Trendsetting. The easy way to connect. Product Information Motor-protective circuit-breaker PKE with electronic wide-range overload protection. Obliged

More information

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

Type MS450 MS497. Phone: Fax: Web:  -   Manual motor protectors Manual motor protectors Type MS40 MS497 MS40 MS497 Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Single-phase1 Horsepower ratings Three-phase 11V 230V

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

IEC CONTACTORS AND OVERLOAD RELAYS

IEC CONTACTORS AND OVERLOAD RELAYS IEC CONTACTORS AND OVERLOAD RELAYS XTCE018C10A, 70 All models shown smaller than actual size. XTCE/XTOB Series Starts at 50 IEC EN 60947 Modular Design Compact Frame Easy to Install XT Series includes

More information

1.1. Reduced Voltage Motor Starters

1.1. Reduced Voltage Motor Starters Reduced Voltage Motor Starters. DS7 Soft Start Controllers Contents Description Type S70, Soft Start Controllers.............. Type S70, Soft Start Controllers with Auxiliary Contact.........................

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

CA Z-EN Overload relays, CT-operated overload relays

CA Z-EN   Overload relays, CT-operated overload relays Overload relays, CT-operated overload relays Electronic overload relays, thermistor overload relay for machine protection Setting ranges (A) (note max. current of the contactor) 0.1-12 0.1-16 0.1-38 6-75

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Reduced Voltage Motor Starters

Reduced Voltage Motor Starters Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ DS7 Soft Start Controllers.................................. Type

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information