Limit switches 3. Page 92. Page 92

Size: px
Start display at page:

Download "Limit switches 3. Page 92. Page 92"

Transcription

1 Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards Products IEC --, EN --, UL, CSA C- n Machine assemblies IEC -, EN - Product certifications UL, CSA, CCC Protective treatment Version Standard: TC and TH Ambient air temperature For operation - + C For storage - + C Vibration resistance Conforming to IEC -- gn ( Hz) Shock resistance Conforming to IEC -- gn ( ms) Electric shock protection Class II conforming to IEC and NF C - Degree of protection IP conforming to IEC ; IK conforming to EN Repeat accuracy on the tripping points, with million operating cycles for head with end plunger Cable entry Depending on model Tapped entry for n cable gland or tapped ISO M x Materials Bodies and heads: plastic

2 General characteristics (continued) Contact block characteristics Rated operational characteristics XEpP XEpP a AC-; A (Ue = V, Ie = A); Ithe = A c DC-; Q (Ue = V, Ie = A), conforming to IEC -- Appendix A, EN -- a AC-; B (Ue = V, Ie = A); Ithe = A c DC-; R (Ue = V, Ie = A), conforming to IEC -- Appendix A, EN -- Rated insulation voltage XEpP Ui = V degree of pollution conforming to IEC - Ui = V conforming to UL, CSA C- n XEpP Ui = V degree of pollution conforming to IEC - Ui = V conforming to UL, CSA C- n Rated impulse withstand voltage XEpP U imp = kv conforming to IEC -, IEC XEpP U imp = kv conforming to IEC -, IEC Positive operation (depending on model) NC contacts with positive opening operation conforming to IEC -- Appendix K, EN -- Resistance across terminals y mω conforming to IEC - category Short-circuit protection XEpP A cartridge fuse type gg (gl) XEpP A cartridge fuse type gg (gl) Connection (screw clamp terminals) XESPp Clamping capacity, min: x, max: x XENPp Clamping capacity, min: x, max: x XESP Clamping capacity, min: x, max: x XENP and XESP Clamping capacity, min: x, max: x or x Minimum actuation speed XESPp, XES P and XES P: m/minute XENPp and XEN P: m/minute Electrical durability b Conforming to IEC -- Appendix C b Utilisation categories AC- and DC- b Maximum operating rate: operating cycles/hour b Load factor: XESPp, XESP XENPp XESP AC supply / Hz a o inductive circuit DC supply c AC supply / Hz a o inductive circuit DC supply c Millions of operating cycles Power broken in W for million operating cycles Power broken in W for million operating cycles Power broken in W for million operating cycles Voltage V Voltage V Voltage V o W o W o W For XES Pp on a or c, NC and NO contacts simultaneously loaded to the values shown with reverse polarity XESPpppp XENPpppp Millions of operating cycles V / V V V Ithe Ithe Current in A V / V V V Current in A Power broken in W for million operating cycles Power broken in W for million operating cycles Voltage V Voltage V o W o W Millions of operating cycles Millions of operating cycles Current in A Ithe V // V V Ithe // V V V Current in A Millions of operating cycles V V / V Ithe V Current in A

3 References, characteristics Complete switches with cable entry Type of head Plunger (fixing by the body) Rotary (fixing by the body) Form B () Form C () Form A () Form D () Type of operator Metal end plunger Steel roller plunger Thermoplastic roller lever () Elastomer roller lever, Ø () References of complete switches with ISO M x cable entry() -pole NC + NO (XESP) -pole NC + NO break before make, (XENP) -pole NC + NC (XESP) -pole NC + NC (XENP) -pole (XESP) -pole break before make, slow break (XENP) Variable length thermoplastic roller lever () Variable length elastomer roller lever, Ø () Round thermoplastic rod lever, Ø () () XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH XCKSH ZCKSH + ZCKD ZCKSH + ZCKD ZCKSDH + ZCKD ZCKSDH + ZCKD ZCKSH + ZCKD ZCKSH + ZCKD ZCKSDH + ZCKD ZCKSDH + ZCKD ZCKSH + ZCKD ZCKSH + ZCKD ZCKSDH + ZCKD ZCKSDH + ZCKD ZCKSH + ZCKD ZCKSH + ZCKD ZCKSDH + ZCKD ZCKSDH + ZCKD ZCKSH + ZCKD ZCKSH + ZCKD ZCKSDH + ZCKD ZCKSDH + ZCKD ZCKSH + ZCKD ZCKSH + ZCKD ZCKSDH + ZCKD ZCKSDH + ZCKD ZCKSH + ZCKD ZCKSH + ZCKD ZCKSDH + ZCKD ZCKSDH + ZCKD Weight (kg) Contact operation closed open (A) = cam displacement (P) = positive opening point NC contact with positive opening operation References of complete switches with Pg cable entry For an entry tapped for a Pg cable gland, delete H from the end of the reference Example: XCKSH becomes XCKS Characteristics Switch actuation On end By cam By any moving part Type of actuation Maximum actuation speed m/s m/s m/s Mechanical durability () (in millions of operating cycles) Minimum force or torque (P) (P) - - (P) (P) (P) (A) (P) (P) (A) (A) (A) (A) (P) (P) (P) (P) (P) For tripping N N Nm For positive opening N N Nm Cable entry entry tapped M x for ISO cable gland, clamping capacity to () Form conforming to EN, see page () Adjustable throughout in steps, or in steps by reversing the notched washer () Switches with gold contacts or eyelet type connections: please consult our Customer Care Centre () Adjustable throughout in steps, or in steps by reversing the lever mounting () Value taken with actuation by moving part at from the fixing () Limited to million operating cycles for switches with contacts XEpP (P) (A) (P) - - (P) (P) (P) (P)

4 Dimensions Complete switches with cable entry XCKSpH ZCKSp + ZCKD XCKSpH ZCKSp + ZCKD XCKSpH ZCKSp + ZCKD () () () XCKSpH ZCKSp + ZCKD = = XCKSpH ZCKSp + ZCKD = = XCKSpH ZCKSp + ZCKD = = () () () = = = = = = XCKSpH ZCKSp + ZCKD () () () = = () () tapped entry for ISO M x or Pg cable gland () Ø rod, length () max () max Ø: elongated holes Ø x

5 Presentation Variable composition Square rod lever, steel, U L = () Round rod lever, glass fi bre, Ø L = () ZCKD ZCKD ZCKD Round rod lever, thermoplastic, Ø L = () Elastomer roller lever, Ø () Variable length elastomer roller lever, Ø () ZCKD ZCKD ZCKD Variable length thermoplastic roller lever, () Thermoplastic roller lever () ZCKD Steel roller lever () ZCKD Steel ball bearing mounted roller lever () ZCKD Spring rod Cat s whisker Spring-rod lever with thermoplastic end () ZCKD ZCKD ZCKD Spring-rod lever, metal () ZCKD Metal end plunger ZCKD End metal plunger with protective boot ZCKD Steel roller plunger ZCKD Steel roller plunger with protective boot ZCKD Body with -pole contact, cable entry for Pg step () Body with -pole contact, cable entry for Pg step () ZCKS, S, S, S, S ZCKS, S ZCKSD, SD, SD, SD () For further details see page For a cable entry tapped ISO M x, add H to the reference Example: ZCKS becomes ZCKSH () Adjustable throughout in steps, or in steps by reversing the notched washer () Adjustable throughout in steps, or in steps by reversing the lever mounting

6 Presentation (continued) Variable composition Square rod lever, steel, U L = () Round rod lever, glass fi bre, Ø L = () Round rod lever, Ø L = () ZCKY ZCKY ZCKY Spring-rod lever with thermoplastic end () Spring-rod lever, metal () ZCKY ZCKY Variable length thermoplastic roller lever, () Variable length steel roller lever () Variable lengthelastomer roller lever, Ø () Elastomer roller lever, Ø () ZCKY ZCKY ZCKY ZCKY Thermoplastic roller lever () Steel roller lever () Steel ball bearing mounted roller lever () ZCKY ZCKY ZCKY For actuation from left AND right or from left OR right ZCKD Body with double-pole CO, staggered, contact cable entry for Pg step, from left AND from right () ZCKS () For further details see page For a cable entry tapped ISO M x, add H to the reference Example: ZCKS becomes ZCKSH : NC contact with positive opening operation or head assuring positive opening operation () Adjustable throughout in steps, or in steps by reversing the notched washer () Adjustable throughout in steps, or in steps by reversing the lever mounting

7 References Adaptable sub-assemblies Bodies with -pole contact Type With contact block step NC + NO (XESP) Scheme Positive Cable entry Reference Weight operation () kg Pg ZCKS ISO M x ZCKSH ZCKSp ZCKS CO (XESP) NC + NO (XENP) NO + NC make before break, (XENP) NC + NC (XENP) NO + NO (XENP) NC + NC (XESP) Bodies with double-pole contact and spring return rotary head Without operating lever Type Scheme step from left and from right With contact block CO staggered Bodies with -pole contact and cable entry Type With contact block NC + NO + NO (XESP) (XESP) (XENP) NC + NO + NO (XENP) Scheme Pg ZCKS ISO M x ZCKSH Pg ZCKS ISO M x ZCKSH Pg ZCKS ISO M x ZCKSH Pg ZCKS ISO M x ZCKSH Pg ZCKS Positive operation () ISO M x ZCKSH Pg ZCKS ISO M x ZCKSH Cable entry Reference Weight kg Pg ZCKS Positive operation () () : NC contact with positive opening operation or head assuring positive opening operation ISO M x ZCKSH Cable entry Reference Weight kg Pg ZCKSD ISO M x ZCKSDH Pg ZCKSD ISO M x ZCKSDH Pg ZCKSD ISO M x ZCKSDH Pg ZCKSD ISO M x ZCKSDH

8 References (continued) Adaptable sub-assemblies Contact blocks Type of contact Scheme For body Positive operation () -pole contact NC + NO Reference Weight kg ZCKS XESP XESPp NC + NO ZCKS XENP CO simultaneous ZCKS XESP XENPp NO + NC make before break, ZCKS XENP XESP NC + NC NO + NO ZCKS XENP ZCKS XENP NC + NC -pole contact NC + NO + NO ZCKS XESP ZCKSD XESP XEpPpp ZCKSD XESP ZCKSD XENP NC + NO + NO ZCKSD XENP () : NC contact with positive opening operation or sub-assembly assuring positive opening operation Other versions Gold fl ashed contacts Please consult our Customer Care Centre

9 Operation Adaptable sub-assemblies Heads ZCKD, D with body ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS (P) ZCKSD ZCKSD ZCKSD ZCKSD (P) Heads ZCKD, D with body ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS (A) (P) ZCKSD ZCKSD ZCKSD ZCKSD (P) Heads ZCKD, D, D with body ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKSD ZCKSD ZCKSD ZCKSD (P) /- -/- -/- -/ /- -/- -/- -/- (P) (A) -/- -/- -/- -/- (P) (P) (P) - - (P) (A) (P) - - (P) (P) (A) (P) (P) (P) Heads ZCKD, D, D, D, D, D, D, D with body ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS (P) (P) (A) (P) (P) (A) (P) (A) (P) ZCKSD ZCKSD ZCKSD ZCKSD /- -/- -/- -/ Heads ZCKD (positive operation only assured with a operating lever) with body ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKSD ZCKSD ZCKSD ZCKSD (P) /- -/- -/- -/- (P) (P) (P) Heads ZCKD, D with body ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKS ZCKSD ZCKSD ZCKSD ZCKSD ZCKS (body with head) Unactuated Actuated from left Actuated from right -/- -/- -/- -/ Contact operation G closed H open (A) = cam displacement (P) = positive opening point

10 Dimensions Adaptable sub-assemblies Plunger heads ZCKD ZCKD ZCKD ZCKD Rotary heads ZCKD, D, D ZCKD ZCKD ZCKD ZCKD, D, D ZCKD ZCKD () () () () () ZCK () rod () () () () D U, L = max max D Ø, L = max max D Ø, L = max max Note: operating lever spindle threaded M Multi-directional heads Bodies with contacts ZCKD ZCKD ZCKS, S, S, S, S, S, S ZCKSH, SH, SH, SH, SH, SH, SH ZCKSDp, SDpH () = Ø xø = ZCKS, SH M () = Ø xø = () tapped entry for ISO M x or Pg cable gland Ø: elongated holes Ø x

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK

More information

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR. Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR Presentation type XCR b XCR v With head for rotary movement operators, spring return to off position contact actuation position per direction Page / v With head for rotary movement operators, stay put

More information

Limit switches 0 ZCK E67 ZCK E23 ZCK E62. with contact, cable. entry for Pg 13, fi xed, 1 step (2) (3) ZCK JD3p, ZCK J1, J5, J6, J7, J9

Limit switches 0 ZCK E67 ZCK E23 ZCK E62. with contact, cable. entry for Pg 13, fi xed, 1 step (2) (3) ZCK JD3p, ZCK J1, J5, J6, J7, J9 Presentation Variable composition: standard bodies Thermoplastic roller lever plunger, 1 direction of actuation Steel roller lever plunger, 1 direction of actuation ZCK E1 ZCK E3 Side metal plunger Side

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR Presentation For hoisting and material handling applications XCR b XCR v With head for rotary movement operators, spring return to off position 1 contact actuation position per direction Page 326/6 v With

More information

ZCK-Y39 ZCK-Y49 ZCK-Y33 ZCK-Y34 ZCK-Y31 ZCK-D109 ZCK-D41 ZCK-D06 ZCK-M2H29 ZCK-M2H29

ZCK-Y39 ZCK-Y49 ZCK-Y33 ZCK-Y34 ZCK-Y31 ZCK-D109 ZCK-D41 ZCK-D06 ZCK-M2H29 ZCK-M2H29 ZCK-Y39 ZCK-Y43 ZCK-Y49 ZCK-Y41 ZCK-D239 ZCK-D23 ZCK-D59 ZCK-Y55 ZCK-Y54 ZCK-Y59 ZCK-D219 ZCK-D21 ZCK-D81 ZCK-D91 ZCK-Y91 ZCK-Y31 ZCK-Y33 ZCK-Y34 ZCK-Y81 ZCK-D029 ZCK-D02 ZCK-D05 ZCK-D109 ZCK-D41 ZCK-D06

More information

Limit switches Osiswitch Classic Metal, conforming to CENELEC EN 50041, type XCK J Fixed or plug-in body Variable composition: standard bodies

Limit switches Osiswitch Classic Metal, conforming to CENELEC EN 50041, type XCK J Fixed or plug-in body Variable composition: standard bodies Presentation Metal, conforming to CENELEC EN 41, type XCK J Variable composition: standard bodies ZCKE1 ZCKE ZCKE63 ZCKE64 ZCKE6 ZCKE8 ZCKE6 ZCKE67 ZCKE69 ZCKE61 ZCKE66 ZCKE619 ZCKJ1D, JD, J6D, J7D ZCKJ8D

More information

Presentation. Limit switches. b XC2J. v With head for linear movement (plunger) with 1 cable entry. v With head for rotary movement (lever)

Presentation. Limit switches. b XC2J. v With head for linear movement (plunger) with 1 cable entry. v With head for rotary movement (lever) Presentation b XCJ with cable entry v With head for linear movement (plunger) v With head for rotary movement (lever) General characteristics Environment characteristics Conformity to standards Standard

More information

Limit switches. Steel roller plunger. Metal end plunger with elastomer boot 4.6(P) mm

Limit switches. Steel roller plunger. Metal end plunger with elastomer boot 4.6(P) mm characteristics Complete switches with cable entry Type of head Plunger (fixing by the body) Form B () Form C () Form E () with elastomer boot Steel roller References of complete switches with ISO M x

More information

Components for safety applications

Components for safety applications Presentation CS-P with 1 cable entry With rotary operating head, with elbowed lever (flush with rear of switch) straight lever, f hinged covers and guards Pages /4, /4, /44 CS-PR with 1 cable entry With

More information

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT OsiSense XC Basic Limit Switches XCMN, XCKN, XCNT Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com - www.stevenengineering.com Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com

More information

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

Miniaturized limit switches

Miniaturized limit switches Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit

More information

O bloco de contato XESP2031 é utilizado no corpo ZCKJ4* / ZCKJ404 é tem o seu acionamento escalonado, ou seja:

O bloco de contato XESP2031 é utilizado no corpo ZCKJ4* / ZCKJ404 é tem o seu acionamento escalonado, ou seja: O bloco de contato XESP1 é utilizado no corpo ZCKJ é tem o acionamento instantâneo de todos os seus contato (NA+NF) ao mesmo tempo independente do lado de atuação do cabeçote. O bloco de contato XESP31

More information

Pre wired limit switches

Pre wired limit switches Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B 3 H G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-N Series Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N

More information

Safety detection solutions

Safety detection solutions General, Preventa XY C Presentation are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which could cause injury to persons or damage either to machines

More information

Pendant control stations

Pendant control stations : pages 30075/3 to 30075/6 Characteristics Environment Conforming to standards IEC 947-5-1, EN 60 947-5-1, IEC 337-1, VDE 0660-200 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600,

More information

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry References, characteristics For hoisting and materials handling applications, type XCR Complete switches with cable entry Type of head Rotary with spring return to off position Stay put Maximum displacement

More information

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Complementary Possible differential minimum at low setting Possible differential minimum at high setting Maximum permissible

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms

More information

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Main Range of product Product or component type Pressure sensor type Device short name Pressure sensor size Controlled

More information

K50F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K63F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Product availability : Non-Stock - Not normally stocked in distribution facility Main Range of product Product or component

More information

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66

More information

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Product availability : Stock - Normally stocked in distribution facility Main Range of product Product or component type Pressure

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E0 I E20 I E40 I Contact blocks (standard) M20 ½ NPT 00 NO+NC snap action 0 NO+NC slow action 02 NO+NC slow action with

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65 Limit Switches - Limit Type (PSL) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping

More information

FOOT SWITCHES

FOOT SWITCHES - 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device

More information

Comepi Limit Switches

Comepi Limit Switches Comepi Limit Switches Features and specifications Approvals CSA, culus IP rating (IEC 60529 and EN 60529 OR IEC 536) IP65-67 Operating temperature -25 to 70ºC (low temperature version available -40 to

More information

Limit Switch - Prewired Type Metal Body

Limit Switch - Prewired Type Metal Body Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation

More information

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Limit Type (PS21L) Metal Body IP66 Limit Switches - Limit Type (PS21L) Metal Body IP66 High mechanical resistance Degree of protection IP66 Zinc alloy (Zamack) or aluminium body Positive Opening Operation Minimum Actuation Force/Torque

More information

Screw limit switches XRBA and XR2. Catalogue

Screw limit switches XRBA and XR2. Catalogue XRBA and XR2 Catalogue Contents XRBA and XR2 Selection guide.............................................. page 2 for standard duty: XRBA Presentation.............................................. page

More information

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65 Limit Switches - Limit Type (PS42L) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X. Limit switches pre-wired 3mm & 35mm Metal & plastic casings Limit switches Description Plastic are made of reinforced UL-VO thermoplastic fiberglass, offering double insulation and protection

More information

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic Safety switches Selection diagram Actuators AB BB CB TB S5 SC Thermoplastic Bodies E0 I E20 I E0 I Contact blocks 0 NO+NC slow action 0 2NC slow action 08 2NC slow action (for pull-wire switches) Pg 3,5

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm Limit Switches casing, 3mm, 4mm & 6mm Description are made of aluminum alloy and have a degree of protection of IP 66 and UL type 4X. The casings come in 3 dimensions: LS3M, 3mm width. LS4M, 4mm width.

More information

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

LS Series Limit Switches. Short Form Catalogue AC1300 ABB Short Form Catalogue LS Series Limit Switches AC ABB LS Series Limit Switches Foot Switches Contents Panorama... 2 Limit Switches - Plastic Casing and Metal Casing... 12 Safety Limit Switches - Plastic

More information

Position switches FC series

Position switches FC series A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons haracteristics pendant control station XA-A - 8 pushbuttons Main Range of product Product or component type Device short name omplementary ontrol station type Enclosure material Electrical circuit type

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

LR-LX-LK-LW Safety Switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions

More information

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Product Description They are developed in order to be used for following operations: For monitoring and protection of industrial machines,

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

ED SERIES SAFETY LIMIT SWITCH Description

ED SERIES SAFETY LIMIT SWITCH Description Description The ED series safety limit switches conform to EN 50047 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

ED SERIES SAFETY LIMIT SWITCH

ED SERIES SAFETY LIMIT SWITCH Description The ED series safety limit switches conform to EN 547 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make

More information

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part

More information

PRODUCT SPECIFICATION. Foot Switches. Series.

PRODUCT SPECIFICATION. Foot Switches. Series. PRODUCT SPECIFICATION Foot 46 Series www.wernerelektrik.com Foot Switch Structures...1 Technical Data...2 Model Number Structure - Foot...3 Dimensions...4 Precautions... Foot WERNERS are Rigorous and tough.

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

Rotary limit switches FCR FGR series

Rotary limit switches FCR FGR series Rotary limit switches FCR FGR series Rotary control switches with 00mm rods from up to positions. Control switches with rotary gear from up to 00 rpm with or micro switches. 0 Rotary limit switches FCR

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information

IEC Limit Switches Selection Guide

IEC Limit Switches Selection Guide IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,

More information

Technical data. Standards: IEC/EN BG-GS-ET-15

Technical data. Standards: IEC/EN BG-GS-ET-15 1 Technical data Contact variants 7 30 2 2 Long life Multiple coding Thermoplastic enclosure Double insulated X 3 cable entries M20 Large wiring compartment High level of contact reliability with low voltages

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

FOOT SWITCHES IN THERMOPLASTIC MATERIAL AND ALUMINIUM DIE CAST PS... / PD... SERIES. Symbols P S / P. Dimensions (in mm)

FOOT SWITCHES IN THERMOPLASTIC MATERIAL AND ALUMINIUM DIE CAST PS... / PD... SERIES. Symbols P S / P. Dimensions (in mm) FOOT SWITCHES IN THERMOPLASTIC MATERIAL AND ALUMINIUM DIE CAST PS... / PD... SERIES Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers, machine tools,

More information

IEC Limit Switches Selection Guide

IEC Limit Switches Selection Guide IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Part Numbers. 9007A and 9007C Basic snap switch without enclosures with or without operators 21-6

Part Numbers. 9007A and 9007C Basic snap switch without enclosures with or without operators 21-6 Table of Contents Section Limit Switches Encapsulated Miniature Industrial Snap Switches 9007MS, -8 9007A, p. - Modular, Miniature and Compact Part Numbers 9007A and 9007C Basic snap switch without enclosures

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Safety Limit Switches

Safety Limit Switches Safety Limit Switches with separate actuator Z02: Snap action 2NC Y+Y 3 Bent key 4 Flat key 5 Bent key 6 Flat key 7 Shock absorbing bent key 8 Shock absorbing flat key 9 Adjustable joint key Z11: Snap

More information

Single foot switches - PX and PA series

Single foot switches - PX and PA series Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified

More information

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE SERIES Z/T23 Safety-Rated, Positive-Break Miniature DIN Limit Switches Features & Benefits Positive-Break NC contacts won t stick or weld shut. Watertight design meets IP washdown requirements. Rugged,

More information