6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17

Size: px
Start display at page:

Download "6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17"

Transcription

1 6. Troubleshooting Since the inverter air conditioner is equipped with Electrical control circuits at both Indoor & outdoor unit, the trouble shooting shall be performed according to the error mode. Inside the controller of the outdoor unit (inverter), the large capacity of electrolytic condenser so that it takes the time to discharge after the power off since the electrical charge remains(the charging voltage DC 340V). Take care of the electrical shock by contact on the charging part before the discharge after the power off. (It takes approximately 2 minutes to discharge). 6-1 Basic items for trouble shooting 1. Is the power source proper? The power source shall be in the range of the rated voltage ±10%. If it is out of this range, it may cause the abnormal operation. 2. Is the connection made between the indoor and outdoor unit? The connection between indoor and outdoor unit shall be performed with 4 wire. (connection cable of indoor and outdoor unit + ground wire). 3. The phenomena as follows are not out of order. No Phenomena The operation is not done. The wind comes out but the heating/cooling is not performed. The remote controller does not operate. The wind volume is not adjusted. The temperature is not set. The operation lamp continues to be flickering. The immediate operation starts without control of remote controller when plugged Cause and reason Is the power off or the power unplugged? Does it stop because it is the completion time? Unplug and plug again the power source for 2 minutes. Is the filter clogged with dust or dirty? Is there any direct light on the outdoor unit or any obstacle against it? Is the selected temperature too high? Lower the selected temperature lower than the current one (during cooling). Is the selected temperature too low? Raise the desired temperature than the current one? (during heating) Is the "Fan only Mode" operation? Is the battery run out? Is the battery inserted in the wrong way(+, -)? Is the detection part of the indoor unit blocked? Does it interfered with the radio of neon sign? Is the operation selected among one of Auto / Dry / Turbo / Sleeping? The temperature setting is not required since the wind volume set automatically. Check again at the state of Cooling / Fan only / Heating. Is the operation selected among the Dry / Turbo / Sleeping / Fan only Mode. Since the temperature is automatically set, the temperature setting is not required. Check again at the cooling / heating state. The standard temperature ±2 C during the automatic operation. Push the Operation / Stop button. Unplug and plug the power source. It is the case that the auto restart function works. Auto restart function is the convenient function where the operation state is memorized in the Memory IC during the blackout and the operation restarts when the power comes back. Samsung Electronics 17

2 6-2 The first determination method of troubled part Error mode display of indoor unit TEMPERATURE / ERROR CODE ERROR CODE DISPLAY Discription Indoor Unit Indoor unit room temperature sensor error (open / short) Indoor unit heat exchanger out temperature sensor error(open / short) Indoor unit heat exchanger in temperature sensor error(open / short) EEPROM error Option code setting error Indoor fan motor malfunction Communication error or miss-wiring error Communication error between the indoor unit and outdoor unit Compressor protection error increase of operation current increase of OLP temperature increase of discharge temperature Over current of IPM circuit increase of heatsink temperature BLCD compressor starting error Outdoor unit sensor error (open / short) deice temp-sensor outdoor temp-sensor discharge temp-sensor OLP temp-sensor Outdoor control PCB error Communication error between 2 micom on the outdoor PCB current sensor error heatsink temp-sensor error Voltage sensor error INDOOR PCB Option Code Fan and cable Check point OUTDOOR PCB, Cable between Indoor and outdoor unit Comp. Fan Fan Comp. PCB,Comp wire PCB PCB PCB PCB, Outlet voltage Error display : / / and 2-digit-number are displayed alternately 18 Samsung Electronics

3 6-2-2 Error mode display of outdoor unit board RED GRN YEL ULN2003 LAMP of Display Monitor YELLOW GREEN RED Power Off / VDD NG Comp. Peak Current (O.C.) Communication NG Comp. Starting error Heatsink sensor error Operation DC-Iink overvoltage error 4-Way valve error Heatsink Temp. trip Outdoor Sensor error(open/short) Discharge sensor temp. trip Discharge sensor error(open/short) OLP sensor error(open/short) CT sensor error Unit Over Current protection Deice sensor error(open/short) OLP sensor temp. trip OPTION error (EEPROM) Compressor rotation error DC fan error (SH12BWH only) DC-Link voltage sensor error PFC OC error NO GAS error AC Line zero-crossing error Description : Lamp on : Lamp flickering : Lamp off Samsung Electronics 19

4 6-3 Sequence of trouble shooting for inverter aircon OPERATION START The indoor unit does not work even though the power is plugged. There is no sound "DING" The lamp is not on the display. Check the indoor unit control board. (A) The indoor unit does not work when operated by the remocon. Checking the Remocon.(B) Check the control board and display board of indoor unit.(c) The 2 digit part of indoor LED display shows Error Code and the unit stops several minutes after the indoor uint starts. Check the error code on the LED display(a), (D)-(O) In case of Error Code : Er/E1(D), Er/E5(D), Er/05(D), Er/06(A), E3/01(E) Check the indoor unit In case of Error Code : Er/09 See section 5. Setup the model option In case of Error Code : E3/01 (F) Check the communication line In case of Error Code : E3/E6(H), Er/17(K), In case of Error Code : Er/31(H), Er/32(G), Er/33(G), Er/36(K), In case of Error Code : Er/37(I), Er/38(K) Check the outdoor unit In case of Error Code : Er/11(J), Er/12(M), Er/13(M), Er/14(L), In case of Error Code : Er/15(N), Er/18(O) Check the outdoor unit and outdoor unit installation 20 Samsung Electronics

5 6-3-1 (A) Check of indoor unit control board Unplug the power cord and plug it after 5 seconds. Press the on/off switch located indoor unit inside to operate the air conditioner. If the air conditioner operates, check the remocon and indoor unit display board. If the air conditioner does not operates, check according to the sequence of the followings: Check sequence of indoor unit control board Step 1 : Check whether two wires of power cord (Sky-blue, brown) are connected correctly to the terminal block and Relay on the control board. Step 1 : Sky -blue : connected to "N1" of Terminal block Step 1 : Brown : connected to RY71 Tab terminal (control board outer side) Step 2 : Check whether the wire connected to the terminal block is connected to th control board. (Control board) CN71 RY71 CN71 SKY-BLU BRN BLK (Terminal block) (N1) 1 2 Step 3 : Check whether the fuse (F701)(F702) on the control board is normal. (3.15[A]/250[V]:F701) (1[A]/250[V]:F702) Step 1 : If the fuse is broken, replace it with new one. Step 4 : Check the output voltage of SMPS on the control board. Step 1 : Input power AC178 ~ AC 264V CN22 1-3pin : DC12V Step 1 : - Input power AC178 ~ AC 264V CN22 2-3pin : DC5V Step 1 : - CN22 : As socket not mounted measure at the solder points Step 5 : Check whether the control board gets wet with dew Step 1 : Dry the control board. Step 6 : Check whether tiny metal objects make a short fircuit on the PCB, especially between pins of the surface mount IC. Step 1 : remove the objects. Do not use splay solvent or some components may get damage by solvent (B)(C) Display board and remocon check of indoor unit Check whether the connection wire of Display board is correctly connected to CN53 connector. Check the voltage of remocon battery. - the voltage of one battery shall be higher than about 1.4V, and then the remocon operates normally. Check whether the neon sign is on and the 3 wave long fluorescent lamp is on around the indoor unit. - After putting all lamps of the indoor out and then operate it by remocon. If it operates with the remocon, it is the abnormality due to the interference from the light of lamps. (Aircon unit is normal) (D) Check the indoor temperature sensor and indoor heat exchanger temperature sensor. Take out the thermistor connected to the connector (CN41,CN42) of control board of indoor unit and measure the resistance between two wires and if it is same as follows: it is normal but if not, replace it. Ambient temperature ( C) thermistor [KΩ] 15 C 20 C 25 C 30 C 35 C 40 C Samsung Electronics 21

6 6-3-4 (E) Check of indoor unit fan motor 1. Check whether the wires are connected surely between control board(cn72) and running capacitor(tab). 1. Check whether the wire of fan motor is connected to the control board (CN73,CN74) of indoor unit. 1. Check whether the error mode displays after the strong rotation for approximately 15 seconds since air conditioner turned on. 1. In case the error code displays after the fan motor is rotating for 15 seconds. Defect of HALL IC of fan motor and/or control board. 1. In case that error code displays without fan motor rotating after 15 seconds. Operate with making short circuit of AC side pins of SSR(SS71) of indoor unit control board. And then if the fan motor does not operate, it is the fan motor defect. If it rotates, it is the defect of control board(ss71,ic05,ic04) (F) Check of communication line between the indoor unit and outdoor unit Communication error mode 1. Check of connection 1. Check whether the cable wire connecting the indoor unit with outdoor unit is correctly connected to the (N1), 1, 2 terminal. (If the wire is connected reversely, the communication error occurs) 1. If the cable connecting the indoor unit and outdoor unit is longer than 20m, error mode may occur (shorten the cable length). Check of indoor unit Check whether the connection wire of the terminal block and control board of indoor unit is correct. (Control board) CN71 RY71 CN71 SKY-BLU BRN BLK (Terminal block) (N1) 1 2 Check of outdoor unit Check whether the connection wire of the terminal block and control board of outdoor unit is correct. (Control board) TB-N TB-L CN04 SKY-BLU BRN BLK (Terminal block) (N1) Check of power supply to the outdoor unit 2. After operation of aircon, select the turbo mode and approximately 3minutes later, check whether the red color lamp of control board (to be seen if the top cover of outdoor unit) is on. 2. If the red lamp (LED 3) is not on, check the power part of control board of outdoor unit. 2. Check the connection of reactor. 2. If the red lamp (LED 3) is on and green lamp is flickering, it is normal (G) Check of discharge temperature sensor and comp top OLP temperature sensor. Connector of outdoor unit control board (PIN#3,4 of CN51 - discharge temperature sensor), (PIN#1,2 of CN52-OLP Temperature sensor) Measure the resistance between two wires and if it is same as follows, it is normal but if not, replace. Ambient temperature ( C) thermistor [KΩ] 0 C 10 C 20 C 30 C 40 C 50 C Samsung Electronics

7 6-3-7 (H) Check the defrost temperature sensor and outdoor temperature sensor. Connector of outdoor unit control board (PIN#1,2 of CN51 - outdoor temperature sensor),(pin#3,4 of CN52-deice Temperature sensor) Measure the resistance between two wires and if it is same as follows, it is normal but if not, replace it. Ambient temperature ( C) thermistor [KΩ] 15 C 20 C 25 C 30 C 35 C 40 C (I) Check the heatsink temperature sensor of IPM This sensor is inside of the IPM module and PIN#24,25 of IPM module are the sensor terminal. Usually PIN solder crack or short circuit with small metal object cause sensor error. Check the object to make short circuit and solder condition of these pins. Ambient temperature ( C) thermistor [KΩ] 15 C 20 C 25 C 30 C 35 C 40 C (J) Check of operation current abnormal increase mode The operation abnormal current mode is the protection control for the safe operation by detecting the operation current of inverter aircon by the current sensor on the control board. If the operation current abnormal increase occurs, The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50 C) Reinstall the outdoor unit so that the good ventilation can be made. If the Refrigerant is overcharged. Check the amount of Refrigerant. If the comp is locked. Replace the comp. If the comp is operating without the revolution of fan motor. Check the fan motor connector, replace the fan motor. If the protection cover is operating with bending to the outdoor. Take out the protection cover. If two outdoor units are operating face to face. (the bad ventilation is made) Reinstall the outdoor unit for the good ventilation. The air circulation is bad due to the attachment of falling leaves Take away the leaves for the good ventilation. Check and clean the dirt of current sensor block of outdoor control board. especially IC83 pin solder C437 47uF R459 33K R K (K) Check of Current sensor, Voltage sensor and Communication between 2 micom on the board. These errors are from component trouble on the outdoor control board. Replace the outdoor control board Samsung Electronics 23

8 (L) Check of instantaneous over-current protection of IPM circuit. Inverter instantaneous over-current protection mode is the mode to be actuated in order to prevent the damage of elements from the peak current of IPM circuit elements. In case that the inverter circuit instantaneous over-current protection mode actuates. condition of installation The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50 ( C) ) Reinstall the outdoor unit so that the good ventilation can be made. In case that the operation is made with the cover bent of the outdoor unit. Take out the cover. If two outdoor units are operating face to face, (the bad ventilation is made) Reinstall the outdoor unit for the good ventilation. The air circulation is bad due to the attachment of falling leaves. Take away the leaves for the good ventilation. If the Refrigerant is overcharged. Check the amount of Refrigerant. Unit defect If the comp is locked. Replace the comp. If the comp is operating without the revolution of fan motor. Check the fan motor connector and replace the fan motor. In case the parts of the control board is damaged. Replace the outdoor control board (M) Check of the comp discharge gas temperature and OLP temperature abnormal rise. If the comp discharge gas temperature and OLP temperature rises higher than a certain level, it protects the circuit. If the comp discharge gas temperature and OLP temperature rises abnormally, Condition of installation The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50 ( C) ) Reinstall the outdoor unit so that the good ventilation can be made. In case that the operation is made with the cover bent of the outdoor unit. Take out the cover. If two outdoor units are operating face to face, (the bad ventilation is made) Reinstall the outdoor unit for the good ventilation. The air circulation is bad due to the attachment of falling leaves Take away the leaves for the good ventilation. If the refrigerant is insufficient. Fill up the amount of refrigerant. Unit defect If the comp is locked. Replace the comp. If the comp is operating without the revolution of fan motor Take out the protection cover. Check the fan motor connector and replace the fan motor. 24 Samsung Electronics

9 (N) Check of the heatsink temperature abnormal rise If the air flow around the heatsink on the control box is not good, heatsink temperature will go up and the control box will have damage. So controller check the heatsink temperature and protect at the cirtain limit. Possible troubles are fan motor trouble, fan motor drive circuit trouble and air flow blocking. Condition of installation The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50( C)). Reinstall the outdoor unit so that the ventilation can be made. In case that the operation is made with the cover bent of the outdoor unit. Take out the cover. If two outdoor unit are operatong face to face,(the bad ventilation is made) Reinstall the outdoorunit for the good ventilation. The air circulation is bad due to the attachement of falling leaves. Take away the leaves for the good ventilation. If the refrigerant is insufficient. Fill up the amount of refrigerant. Unit defect If the fan is locked with some object. Remove the object. If the comp is operationg without the revolution of fan motor. Take out the protection cover Check the fan motor connector(cn54), running capacitor, relay(ry503) and replace the fan motor (O) Check BLDC compressor starting error If the compressor have some trouble inside like locking or gas pressure of suction and discharge pipe is not balanced, Inverter system will give up compressor rotation control to protect itself from overcurrent. In case of compressor rotation starting trouble without overcurrent condition, controller detect the compressor rotation error and stop. Compressor wire connection is not good. Check Compressor TAB terminal connection of the wire and connector to control box. Gas pressure balance is not good at stop condition. Check service valve open. Check EEV motor attachement and connector. Compressor is locked or have some mechanical damage. Replace the compressor. Samsung Electronics 25

10 (P) Check no gas error Charge standard amount of refrigerant (Q) Check of 4-Way valve Check whether the wires of 4-Way valve and control board of outdoor units correct. If it is normal, replace 4-Way valve (R) Check of outdoor unit fan motor (SH12BPH only) Check whether the wire of fan motor is connected to the control board (CN01) of outdoor unit. Check the voltage on the control board of outdoor unit and if it is same as follows, replace fan motor. Input power AC178V~AC264V. CN01 1-3pin : DC250V±10% ~ DC370V±10% CN01 4-3pin : DC15V 26 Samsung Electronics

11 6-4 Fault Diagnosis of Major Parts Part Indoor "Temp.Sensor" Indoor "Heat ex. Sensor" Outdoor "Temp.Sensor" Outdoor "Deice Temp. Sensor" Diagnosis Measure resistance with a tester. Ambient temperature 15 C 20 C 25 C 30 C 35 C 40 C thermistor[kω] Outdoor "Discharge Temp.Sensor" Outdoor "OLP Temp.Sensor", OΩ open or short Ambient temperature 0 C 10 C 20 C 30 C 40 C 50 C thermistor[kω] , OΩ open or short Indoor Fan Motor Measure the voltage between terminals (CN72) with a tester At ambient temperature (10 C ~ 30 C) between Voltage[V] Red, Blue 410±10% Main Red, Yellow 325±10% Sub Measure the voltage between ground and signal wire of the fan motor between Gray, Orange Yellow, Orange Voltage 0.5V~4.5V 5V if voltage does not change from 0V to 5V. Outdoor Fan Motor At ambient temperature (10 C ~ 30 C) between Resistance[Ω] Black, Red 275±10% Main Black, Yellow 350±10% Sub, OΩ open or short Stepping Motor (UP/DOWN swing motor) Measure resistance between red wire and each terminal. Approx. 290Ω at ambient temperature (20 C ~30 C), OΩ open or short Stepping Motor (FRONT GRILLE motor) Measure resistance between red wire and each terminal. Approx. 110Ω at ambient temperature (20 C ~30 C), OΩ open or short Samsung Electronics 27

No Operation of air conditioner Explanation

No Operation of air conditioner Explanation 12. Troubleshooting 12-1 Items to be checked first 1. The input voltage should be rating voltage ±10% range. The air conditioner may not operate properly if the voltage is out of this range. 2. Is the

More information

12. Troubleshooting Items to be checked first. Samsung Electronics

12. Troubleshooting Items to be checked first. Samsung Electronics 12. Troubleshooting 12-1 Items to be checked first 1. The input voltage should be rating voltage ±10% range. The air conditioner may not operate properly if the voltage is out of this range. 2. Is the

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU18RLF ASU24RLF AOU18RLXFW AOU24RLXFW R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL OPERATION

More information

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units Universal and Multi Split Units If there is a fault on any LG Universal or Multi unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller

More information

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely.

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely. 9. Maintenance 9.1 Precautions before Maintenance electrolytic capacitor after power off. A B A B maintenance safely. 50 9.2 Error Code List Unit o. ame Display 8 nixie 0.5s) Operation Indicator Cool Indicator

More information

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218 troubleshooting Table of Contents 1. Troubleshooting Model Numbers: Indoor Unit: KDIR09-H2, KTIR09-H2, KUIR09-H2 KDIR12-H2; KTIR12-H2, KUIR12-H2 KDIR18-H2, KTIR18-H2, KUIR18-H2 KDIR24-H2, KTIR24-H2, KUIR24-H2

More information

LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H

LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H LUV INVERTER SERIES Part 2 of 2 Self-diagnostics and Trouble-shooting 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H MAJOR COMPONENT CHECKING COMPRESSOR Use a multi-meter

More information

QUARTZ INVERTER TROUBLESHOOTING GUIDE

QUARTZ INVERTER TROUBLESHOOTING GUIDE QUARTZ INVERTER TROUBLESHOOTING GUIDE QIN415H2V31 QIN618H2V31 QIN721H2V31 QIN1129H2V31 INVERTER MINI SPLIT SYSTEM WARNING The information contained in the manual is intended for use by a qualified service

More information

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART.   Vi håper de får stor glede av et Novema kulde produkt! Driftsinstruks Utopia kontroller feilkoder PCP-2HTE og PC-ART Vi håper de får stor glede av et vema kulde produkt! www.novemakulde.no 8/14 TROUBLESHOOTING 8.2. TROUBLESHOOTING PROCEDURE 8.2.1. ALARM CODE

More information

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers: KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING Model Numbers: KSID012-H115Q KSID022-H215Q KSID016-H215Q WARNING Installation MUST conform with local building codes or, in the

More information

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTE... 3 FAULT FINDING AND DIAGNOSTICS... 3 ABBREVIATIONS... 3 PCB S... 4 OUTDOOR MAIN PCB... 4 INDOOR PCB...

More information

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance 9. Maintenance 9.1 Precautions before Maintenance Service Manual pacitor after power off. - discharge resistance or plug of soldering iron A B A B - nance safely. 40 9.2 Error Code List O. 1 2 3 4 5 6

More information

5. TROUBLE DIAGNOSIS

5. TROUBLE DIAGNOSIS . TROBLE DIAGNOSIS -1. Contents of Remote Controller Switch Alarm Display... -2-2. Outdoor nit Control anel LED Display... -4-3. AC System Alarm Codes... - -4. Inspection of arts (Outdoor nit)... -68 -.

More information

LIGHT COMMERCIAL. Troublesooting

LIGHT COMMERCIAL. Troublesooting LIGHT COMMERCIAL Troublesooting 2. 2.1 Display board 2.1.1 Icon explanation on indoor display board (Super slim cassette 24K). 2.1.2 Icon explanation on indoor display board (Compact cassette 12K, 18K).

More information

2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG LS-Q096ADL, LS-Q096ADG, LS-Q096BAG LS-Q096BAG, LS-Q096BDG, LS-Q096BDL LS-Q082BAM CN-TH TRIAC MOTOR CN-U/D STEP

2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG LS-Q096ADL, LS-Q096ADG, LS-Q096BAG LS-Q096BAG, LS-Q096BDG, LS-Q096BDL LS-Q082BAM CN-TH TRIAC MOTOR CN-U/D STEP Wiring Diagram (1) Indoor Unit 1. LS-Q076A, LS-Q076BBG, LS-Q076BEL LS-Q096A, LS-Q096ABG, LS-Q066AHG LS-Q096AEL, LS-Q096BBG, LS-Q096ABM LS-Q096AEM 2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG LS-Q096ADL, LS-Q096ADG,

More information

KMIR. Multi outdoor units. troubleshooting Multi zone CONDENSING UNITS MKMIR218-H221, KMIR327-H217, KMIR436-H217, KMIR545-H219.

KMIR. Multi outdoor units. troubleshooting Multi zone CONDENSING UNITS MKMIR218-H221, KMIR327-H217, KMIR436-H217, KMIR545-H219. Multi outdoor units KMIR troubleshooting Multi zone CONDENSING UNITS Model Numbers: MKMIR218-H221, KMIR327-H217, KMIR436-H217, KMIR545-H219 Table of Contents 1. Trouble Shooting WARNING Installation MUST

More information

Fault Codes. J control

Fault Codes. J control J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 Enter unit inspection mode by pushing the UP and DOWN buttons simultaneously for two seconds. Ensure that the

More information

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UM27B1C3 INDOOR UNIT AM27B1C07 AM27B1C Installation. 2. Disassembly and Reassembly

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UM27B1C3 INDOOR UNIT AM27B1C07 AM27B1C Installation. 2. Disassembly and Reassembly ROOM AIR CONDITIONER INDOOR UNIT AM27BC07 AM27BC3 OUTDOOR UNIT UM27BC3 SERVICE Manual AIR CONDITIONER. Installation CONTENTS 2. Disassembly and Reassembly 3. Troubleshooting 4. Exploded Views and Parts

More information

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units Universal and Multi Split Units If there is fault on any LG universal or multi unit a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the

More information

PART7. Trouble Shooting

PART7. Trouble Shooting PART7. Trouble Shooting 1. Indoor Unit Error Display Display E0 E1 E2 E3 E5 LED STATUS EEPROM parameter error Indoor unit and outdoor unit communication protection Zero-crossing signal error Indoor fan

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASH9LSACW ASH12LSACW Outdoor unit AOH9LSAC AOH12LSAC CONTENTS SPECIFICATIONS...................... 1 DIMENSIONS..........................

More information

EcoNet and Flash Codes

EcoNet and Flash Codes The error codes below will be displayed at the EcoNet Control Center under Service window / Current Faults or in the Fault History and will be time & date stamped. VSODC (Variable Speed Outdoor Unit Control

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE Indoor unit AGYF09LAC AGYFLAC AGYFLAC AGYFLAC Outdoor unit AOYV09LAC AOYVLAC AOYVLAC AOYVLAL CONTENTS SPECIFICATIONS..................... DIMENSIONS.........................

More information

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems. All Seasons CLIMATE COMFORT Heating 3. SERVICE TOOLS 3.2. Inverter checker RSUK09-17 Air Conditioning Applied Systems Refrigeration 3.2. Inverter checker RSUK09-17: index 1. Outlook 2. How to connect?

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit Outdoor unit ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC CONTENTS SPECIFICATIONS....................... 1 OUTLINE AND DIMENSIONS............

More information

RAC Product Trouble Shooting Guide

RAC Product Trouble Shooting Guide 1 RAC Product Trouble Shooting Guide Model : Wall Mount Inverter Type CAUTION Make sure to fully read and understand the safety precautions described in the SVC manual before SVC. Only authorized personnel

More information

9. Maintenance. 9.1 Error Code List. Service Manual. Installation and Maintenance

9. Maintenance. 9.1 Error Code List. Service Manual. Installation and Maintenance 9. Maintenance 9.1 Error Code List o. ame Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status during Dual-8 ing, O 0.5s OFF ing,

More information

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units FS2MIF-141AE2 FS2MIF-181AE2 FS3MIF-211AE2 FS3MIF-271AE2 FS4MIF-281AE2 FS4MIF-361AE2 FS5MIF-421AE0 NOTE: Before servicing the unit,

More information

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4.

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. SYSTEM AIR CONDITIONER 4 WAY CASSETTE SERIES INDOOR UNIT Model : AC018NN4DCH/AA AC024NN4DCH/AA AC030NN4DCH/AA AC036NN4DCH/AA AC042NN4DCH/AA AC048NN4DCH/AA OUTDOOR UNIT AC018JXADCH/AA AC024JXADCH/AA AC030JXADCH/AA

More information

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RL ASURL Outdoor unit AOU8RL AOURL CONTENTS SPECIFICATIONS................... DIMENSIONS...................... REFRIGERANT SYSTEM DIAGRAM....

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W363DGU1(Set) ASNW363DGU1 ASUW363DGU1 AS-W303DGU1(Set) ASNW303DGU1 ASUW303DGU1 CAUTION Before Servicing

More information

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5. SYSTEM AIR CONDITIONER 4 WAY CASSETTE SERIES Model : INDOOR UNIT AC052MN4DKH AC071MN4DKH AC090MN4DKH AC100MN4DKH AC120MN4DKH AC140MN4DKH OUTDOOR UNIT AC090MXADKH AC100MXAD H AC120MXAD H AC140MXAD H AIR

More information

VAL6 KBE5S. Service Manual

VAL6 KBE5S. Service Manual VAL6 KBE5S Service Manual 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel Tank Capacity 9 gallons Fuel Consumption 0.85gallon/h Power Source 120V, 60Hz single phase Power

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UM26A1C2 UM18A1C2 INDOOR UNIT AM26A1C13 AM18A1C Installation. 2. Disassembly and Reassembly

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UM26A1C2 UM18A1C2 INDOOR UNIT AM26A1C13 AM18A1C Installation. 2. Disassembly and Reassembly ROOM AIR CONDITIONER INDOOR UNIT AM6AC3 AM8AC09 OUTDOOR UNIT UM6AC UM8AC SERVICE Manual AIR CONDITIONER. Installation CONTENTS. Disassembly and Reassembly 3. Troubleshooting 4. Exploded Views and Parts

More information

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3. 1332 TROUBLESHOOTING GUIDE Maintenance The Drive is convection or fan cooled by air flowing through the heat sink slots. The slots must never be allowed to become obstructed with dirt or foreign matter.

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit C24YE MC24Y3E MR24Y3E1 SPECIFICATIONS TYPE COOL & HEAT INDOOR UNIT MC24Y3E OUTDOOR UNIT MR24Y3E1 COOLING CAPACITY 23,500-22,500

More information

PANASONIC FAULT CODE GUIDE. ECOi ECO-G - PACi

PANASONIC FAULT CODE GUIDE. ECOi ECO-G - PACi PANASONIC FAULT CODE GUIDE ECOi ECO-G - PACi 1 Page INDEX P3 GHP ENGINE ISSUES P4 CENTRAL CONTROLLER ISSUES P5 ADDRESSING & COMMUNICATION PROBLEMS P6 SENSOR FAULTS P7 COMPRESSOR ISSUES P8 INCORRECT SETTINGS

More information

SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET SUPER DC INVERTER MULTI TYPE

SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET SUPER DC INVERTER MULTI TYPE SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET SUPER DC INVERTER MULTI TYPE M2OE-14HFN1-Q M2OF-18HFN1-Q M3OE-21HFN1-Q M3OE-27HFN1-Q M4OE-28HFN1-Q M4OB-36HFN1-Q M5OE-42HFN1-Q DC MULTI OUTDOOR UNITS CONTENTS

More information

Heat Recovery Ventilation

Heat Recovery Ventilation .book Page i Thursday, March 30, 2000 3:31 PM Heat Recovery Ventilation VAM 500EJ VAM 800EJ VAM1000EJ VAM2000EJ VAM500~1000EJ VAM2000EJ Table of Contents i .book Page ii Thursday, March 30, 2000 3:31 PM

More information

Part 2 Functional Description

Part 2 Functional Description ESIE06-0 Part Functional Description What is in this part? This part contains information on the functions used to control the system. Understanding these functions is vital when diagnosing a malfunction

More information

HWP Protection Board

HWP Protection Board February 2009 HWP Protection Board Features and Operation This board provides the system protection features necessary to keep our HWP (Water Sourced Heat Pump) units safe in the instances when they are

More information

Pagina 1 di 1 INSPECTION In-car air sensor is located at crash pad. It is installed with humidity sensor. It will detect interior, which will be used for discharge control, sensor failsafe, door control,

More information

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES Article Text ARTICLE BEGINNING 1993 AIR CONDITIONING & HEAT A/C General Diagnostic Procedures Diagnosis is an important first step in A/C system servicing. To save time and effort, systems should be carefully

More information

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING TROUBLESHOOTING for the 5 BUTTON 3109228.001 COMFORT CONTROL CENTER SYSTEM INTRODUCTION The Comfort Control Center control system can be used to operate the following Duo-Therm Units: Roof Top Air Conditioners

More information

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL Dual Rating NRTL/C CERTIFIED Technologies Inc. mgitech.com Sensor/Sensorless Vector Control Dual current rated for constant and variable torque Auto

More information

PANcharge1k Battery Charger User's Manual

PANcharge1k Battery Charger User's Manual PANcharge1k Battery Charger User's Manual Ver.1.00E Table of Contents 1. Important Safety Instructions... 3 1-1 General Safety Precautions... 3 1-2 Battery Precautions... 3 1-3 Electromagnetic Disturbance...

More information

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual VAL6 Infrared Heater KBE5S & KBE5L (2-step) Maintenance Manual Wiring Diagram of Burner Control KBE5S KBE5L 2-step Sequence Time Chart Operation Switch ON ignition OFF Fan Igniter Solenoid Pump 5 sec.

More information

Fault Code Check List

Fault Code Check List Fault Code Check List This Fault Code Check List is intended to provide an easy-to-use, quick reference guide on all Fault Codes across our product range. As the information in here is limited, please

More information

INSTALLATION AND MAINTENANCE

INSTALLATION AND MAINTENANCE ISTALLATIO AD MAITEACE TROUBLESHOOTIG Content: 1. Precautions before Performing Inspection or Repair 2. Confirmation 3. Flashing LED of Indoor/Outdoor Unit and Primary Judgement 4. How to Check Simply

More information

Trouble Shooting a Jouan C/CR4.22 Centrifuge

Trouble Shooting a Jouan C/CR4.22 Centrifuge The world leader in serving science Trouble Shooting a Jouan C/CR4.22 Centrifuge No Spin Condition Erratic Speed Control No Cooling General Parts List Wiring Diagram No Spin Condition (Removing the Front

More information

Multi Zone Air Conditioner SVC MANUAL(General)

Multi Zone Air Conditioner SVC MANUAL(General) Multi Zone Air Conditioner SVC MANUAL(General) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 960-914-09 Air Conditioner Service

More information

INSTALLATION MANUAL. Free Joint Multi & Multi-Split Type Room Air Conditioner (Cooling and Heating)

INSTALLATION MANUAL. Free Joint Multi & Multi-Split Type Room Air Conditioner (Cooling and Heating) INSTALLATION MANUAL Free Joint MH040FXEA2A MH052FXEA2A Fixed MH18VV1X MH19VV1X ENGLISH Free Joint Multi & Multi-Split Type Room Air Conditioner (Cooling and Heating) EΛΛHNIKA PORTUGUÊS ITALIANO ESPAÑOL

More information

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

ZIP Economizer Fault Detection and Diagnostics (FDD) Table Fault Detection and Diagnostics (FDD) Table Fault Detection Problem Diagnostic ction (in addition to alarm stored / transmitted) Potential Cause C Fault Code OT sensor predetermined range O damper returns

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit

4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit 4.Failure phenomenon Phenomenon Mirage comes out from indoor unit Noise Sometimes, the room is smelly when heating, there is no wind at the beginning of starting unit Causing explanation When the cold

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6

More information

SERVICE Manual AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT US12A2VC US09A2VA US07A2VA AS12A2VC AS09A2VA AS07A2VA. 1. Installation

SERVICE Manual AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT US12A2VC US09A2VA US07A2VA AS12A2VC AS09A2VA AS07A2VA. 1. Installation ROOM AIR CONDITIONER INDOOR UNIT ASAVC AS09AVA AS07AVA OUTDOOR UNIT USAVC US09AVA US07AVA SERVICE Manual AIR CONDITIONER CONTENTS. Installation. Disassembly and Reassembly. Troubleshooting 4. Exploded

More information

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS. SPLIT-TYPE, AIR CONDITIONERS Revision A: MU-A2YV - E can be connected to MCF-A2WV - E. Please void OB330. SERVICE MANUAL Wireless type Models E MU-A07YV - E MU-A09YV - MU-A2YV - E HFC utilized R40A No.

More information

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

1333 (SERIES B & C) TROUBLESHOOTING GUIDE 1333 (SERIES B & C) TROUBLESHOOTING GUIDE Preventive Maintenance: Problems with Your Drive? Bulletin 1333 is convection or fan cooled by air flowing through the heat sink slots. The slots must never be

More information

Owner s Manual Currency Counter

Owner s Manual Currency Counter Owner s Manual 4820 Currency Counter TABLE OF CONTENTS 1. Product View 1.1. Front and Rear Views 1.2. LED Display/Control Panel 1.3. Side Control Panel 2. Operation 2.1 Operation Modes 2.2 The Right Way

More information

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UD26A1C2 UD18A1C2 INDOOR UNIT AD26A1C13 AD18A1C Installation. 2. Disassembly and Reassembly

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UD26A1C2 UD18A1C2 INDOOR UNIT AD26A1C13 AD18A1C Installation. 2. Disassembly and Reassembly ROOM AIR CODITIOER IDOOR UIT AD6AC3 AD8AC09 OUTDOOR UIT UD6AC UD8AC SERVICE Manual AIR CODITIOER. Installation COTETS. Disassembly and Reassembly 3. Troubleshooting 4. Exploded Views and Parts List 5.

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit Outdoor unit RSW-17AC ROW-17AC C O N T E N T S SPECIFICATIONS........................................ 1 REFRIGERANT SYSTEM DIAGRAM........................

More information

ST Charger. Industrial Battery Charger

ST Charger. Industrial Battery Charger ST Charger Industrial Battery Charger Installation and Operation Manual ST_13 Table of Contents Pg# 1.0 INSTALLATION 1 1.1 Receiving 1 1.2 Location 1 1.3 Line Voltage 1 1.4 A.C. Service Requirements 2

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W093F2B2(LAN090HVP/LAU090HVP) AS-W123F2B2(LAN120HVP/LAU090HVP) CAUTION Before Servicing the unit, read

More information

OUTDOOR UNIT CONTROLLER (OUC)

OUTDOOR UNIT CONTROLLER (OUC) AUCKLAND temperzone Ltd 38 Tidal Road, Mangere, Auckland. Private Bag 93303, Otahuhu, N.Z. Phone 0-9-279 5250 Fax 0-9-275 5637 Email sales@temperzone.co.nz WELLINGTON Phone 0-4-569 3262 Fax 0-4-566 6249

More information

SERVICE Manual AIR CONDITIONER INDOOR UNIT MH18ZC1(C2)-09 MH19ZC1(C2)-07 MH19ZC1(C2)-12 MH24ZC1(C2)-12 MH26ZC1(C2)-07 MH26ZC1(C2)-12

SERVICE Manual AIR CONDITIONER INDOOR UNIT MH18ZC1(C2)-09 MH19ZC1(C2)-07 MH19ZC1(C2)-12 MH24ZC1(C2)-12 MH26ZC1(C2)-07 MH26ZC1(C2)-12 ROOM AIR CODITIOER IDOOR UIT MH8ZC(C2)-09 MH9ZC(C2)-07 MH9ZC(C2)-2 MH24ZC(C2)-2 MH26ZC(C2)-07 MH26ZC(C2)-2 OUTDOOR UIT MH8ZC(C2)X MH9ZC(C2)X MH24ZC(C2)X MH26ZC(C2)X SERVICE Manual AIR CODITIOER COTETS.

More information

DTC P2118 THROTTLE ACTUATOR CONTROL MOTOR CURRENT RANGE/PERFORMANCE

DTC P2118 THROTTLE ACTUATOR CONTROL MOTOR CURRENT RANGE/PERFORMANCE 0560 05NY0 DTC P8 THROTTLE ACTUATOR CONTROL MOTOR CURRENT RANGE/PERFORMANCE CIRCUIT DESCRIPTION The Electronic Throttle Control System (ETCS) has a dedicated power supply circuit. The voltage () is monitored

More information

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13. MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. - 1 - Table of Contents 1. SALIENT FEATURES...3 2.. PRODUCT INSTALLATION & PRECAUTIONS...3 2.1. PRODUCT INSTALLATION &

More information

Advanced EasyStart Troubleshooting

Advanced EasyStart Troubleshooting Advanced EasyStart Troubleshooting EasyStart is designed for excellent reliability and durability. Every EasyStart is tested on a compressor before it leaves Micro-Air to ensure it will work when delivered.

More information

Refrigerators (Combis)

Refrigerators (Combis) Refrigerators (Combis) MODEL : * ERF-384A Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information,please

More information

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS ELECTRIC FENCE ENERGIZER MODEL 950 SERVICE MANUAL Service Manual for OLLI 950 Page 1/16 Date 20.10.2014 Table of Contents...1 1. IMPORTANT SAFETY INSTRUCTIONS...2 2. SPECIFICATIONS...3 3. CONSTRUCTION...4

More information

AIR CONDITIONER SECTION AC CONTENTS AUTO

AIR CONDITIONER SECTION AC CONTENTS AUTO AIR CONDITIONER SECTION AC CONTENTS AUTO PRECAUTIONS AND PREPARATION SRS Airbag Pretensioner Seatbelt... 4 A/C Refrigerant HFC134a Handling... 4 Compressor Oil... 4 Tube Connection... 4 O-Ring Part Number...

More information

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart Service Manual Contents 1. Names of components 2 2. Safety Devices 3 3. Specifications 4 4. Wiring Diagam 4 5. Sequence Time Chart 5 6. 7. 8. Troubleshooting 6 Standard resistance & Voltage 13 Check &

More information

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual FinishPro 390/395 Airless/AirAssisted Sprayer Repair Electrical Manual First choice when quality counts. Rev. B 10/11 /07 FinishPro 395 3.00 ti9026a Red Yel Yel Air Hose Connection FinishPro 390 Exhaust

More information

CEILING WALL type INVERTER

CEILING WALL type INVERTER SPLIT TYPE ROOM AIR CONDITIONER CEILING WALL type INVERTER Models Indoor unit AWY14LSAZ AWH14LSAZ AWY17LSAZ AWH17LSAZ Outdoor unit AOY14LSAWC AOH14LSAWC AOY17LSAWC AOH17LSAWC CONTENTS SPECIFICATIONS....................

More information

MODEL : 55A240IUBEM ROTARY COMPRESSOR SPECIFICATION SHEET 1. APPLICATION 2. COMPRESSOR DATA 3. MOTOR DATA 4. ELECTRICAL COMPONENTS

MODEL : 55A240IUBEM ROTARY COMPRESSOR SPECIFICATION SHEET 1. APPLICATION 2. COMPRESSOR DATA 3. MOTOR DATA 4. ELECTRICAL COMPONENTS SPECIFICATION SHEET 1. APPLICATION H/P & Cooling Type Air conditioner Rated & Frequency... 208~230V 1Φ 60Hz Refrigerant.. R-22 2. COMPRESSOR DATA Pump Type Rolling Piston Type Displacement. 33.43cc/rev

More information

SERVICE MANUAL FREE COMBI SERIES FC-E24AI, FC-E28AI

SERVICE MANUAL FREE COMBI SERIES FC-E24AI, FC-E28AI SERVICE MANUAL FREE COMBI SERIES FC-E24AI, FC-E28AI 1.Technical specifications Model Compressor Manufacturer/trademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W)

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners YD360/480/600, YJ-30/-40/-50 and J30/40/50 YD Models 642546-UAI-A-080 GENERAL Standard operation

More information

YN012GMFI16RUD Decription: Model Number: Product Code: Power Supply:

YN012GMFI16RUD Decription: Model Number: Product Code: Power Supply: YN012GMFI16RUD 220037506240 1 Ambient temperature sensor assembly 1 202301310063 4 2 Rear net 1 201237490045 5 3 Condenser assembly 1 201537490008 617 4 Pipe temperature sensor assembly 1 202440500004

More information

1. DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME

1. DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME 2006 Toyota 4Runner 4.0L Eng Limited 1Search AIR CONDITIONER REQUESTED INFORMATION PRECAUTION 1. DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME 2. ALWAYS WEAR EYE PROTECTION Fig 1:

More information

GAMA DOMÉSTICA MULTISPLIT Manual de Servicio

GAMA DOMÉSTICA MULTISPLIT Manual de Servicio GAMA DOMÉSTICA MULTISPLIT Manual de Servicio CONTENTS 1. General information of Outdoor Units... 2 2. Features... 3 3. Dimensions... 4 4. Refrigeration Cycle Diagram... 5 5. Wiring diagram... 7 6. Indoor

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A2UW18GFA0 [LMU18CHV] CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB387

SERVICE MANUAL OUTDOOR UNIT. No. OB387 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision C: MUH-A25VB - E has been added. Please void OB87 REVISED EDITION-B. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB87 REVISED EDITION-C Wireless type

More information

Product Specifications

Product Specifications Product Specifications Split System Heat Pump Up to 18 SEER 2-3-4-5 Ton Capacity R410A Standard Features R-410A chlorine-free refrigerant Load 25%-110% Intelligent oil return technology Inverter Driven

More information

Installation Instructions

Installation Instructions 018A00 CALOWAMB023A00 CALOWAMB037A00 - CALOWAMB042A00 SPLIT SYSTEM AC UNITS ACCESSORY MOTORMASTER R I HEAD PRESSURE CONTROLLER 15 & 20 TONS Installation Instructions IMPORTANT: Read these instructions

More information

BLDC-DZZ Spindle control Unit OPERATION MANUAL. Release: REV-01. Contents

BLDC-DZZ Spindle control Unit OPERATION MANUAL. Release: REV-01. Contents W Windward BLDC-DZZ Spindle control Unit OPERATION MANUAL 1 Release: 2013-3-23 Contents 1 Cautions For Handling and operation.p3 2 Features.P4 3 Specifications.P5 4 CONTROL PANEL FEATURES.P6 5 Changing

More information

SYSTEM AIR CONDITIONER

SYSTEM AIR CONDITIONER SYSTEM AIR CONDITIONER DVM CHILLER AG010KSVAFH/AG015KSVAFH AG010KSVAJH/AG015KSVAJH DVM CHILLER CONTENTS 1. Precautions 2. Product Features and Specifications 3. Disassembly and Reassembly 4. Troubleshooting

More information

3.10 Air Conditioning (A/C) Contents

3.10 Air Conditioning (A/C) Contents 3.10 Air Conditioning (A/C) Contents 3.10 Model 208 as of M.Y. 1998 Diagnosis Page Function Test................................... 11/1 Reading Actual Values............................ 12/1 Version Code...................................

More information

Universal Air Conditioner SVC MANUAL(Exploded View)

Universal Air Conditioner SVC MANUAL(Exploded View) http://biz.lgservice.com Universal Air Conditioner SVC MANUAL(Exploded View) MDEL : AUUW306C (UU30W UEC) CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for authorized

More information

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 FUNCTION DIAGNOSIS... 3 PRECAUTION... 6 PREPARATION...

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 FUNCTION DIAGNOSIS... 3 PRECAUTION... 6 PREPARATION... VENTILATION, HEATER & AIR CONDITIONER SECTION VTL A VENTILATION SYSTEM B C D CONTENTS E FUNCTION DIAGNOSIS... 3 AUTOMATIC AIR CONDITIONER SYSTEM... 3 WITH COLOR DISPLAY...3 WITH COLOR DISPLAY : Switches

More information

SVC MANUAL(Exploded View) Room Air Conditioner

SVC MANUAL(Exploded View) Room Air Conditioner Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W243D8B8(LSN240HSV3/ LSU240HSV3) AS-W303D8B8(LSN307HV3/ LSU307HV3) AS-W363D8B8(LSN360HV3/ LSU360HV3)

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit AUU8RC AUU4RC AOU8RC AOU4RC CONTENTS SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................

More information

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems CDBR-B Dynamic Braking Unit Instruction Manual April 2009 Part Number: 146-10001-R1 Copyright 2009 Electromotive Systems 2009 MAGNETEK All rights reserved. This notice applies to all copyrighted materials

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-25CA RCW-30CA RO-25A RO-30A C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................

More information