R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up
|
|
- Gwenda Norton
- 5 years ago
- Views:
Transcription
1 Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in relay terminal boards (R ) make the R1000 quick and easy to install and repair--ideal for retrofit installations. Several models are available: R a standard enclosure with one R R Terminal Board R an oversized enclosure with one R board; two more R s can be added R a 3-relay version Figure 1: The R1000 Series s Replaceable DPDT (Double-pole, Double-throw) Plug-in Features and Benefits Reduces long-term costs--easy and inexpensive to replace; no need to rewire the entire installation Enclosed ontacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up onduit-friendly Enclosure Allows relay replacement without removing/changing conduit connections Snap-in Terminal Board for Field Retrofit Reduces installation time Integral Eliminates the need for a separate transformer in the application; saves time and money Product Overview The R1000 Series includes a variety of products that can be tailored to a wide array of new and retrofit installations. Four models comprise the R1000 family; see Table Johnson ontrols, Inc. ``````````4P```` Part No , Rev. ode No. LIT
2 The R1000 Series is compatible with a wide variety of low voltage controllers and features components that are easily removed and replaced. The R and -20 come with one R terminal board, which easily snaps out when needed. See Table 3 for competitive wiring cross references. In addition, the DPDT relay unplugs for easy replacement and features a dust cover, which minimizes particulate contamination of the contacts. Table 1: The R1000 Series Part Number Description Power Available Enclosure R One R board in a standard enclosure R terminal board for R and -20; includes one DPDT relay, load resistor, and transformer R One R board supplied in an enclosure, with the capability of adding two more R s R relay version of the R1000-1, with a single transformer in an enclosure D imensions 24 VA, 5 VA Standard size (5 1/4 in. H x 4 1/4 in. W x 2 15/16 in. D) (132 mm x 118 mm x mm 74) 24 VA, 5 VA Not included 24 VA, 5 VA (on each R installed) Oversized (5 1/4 in. H x 12 1/2 in. W x 2 15/16 in. D) (132 mm x 318 mm x 74 mm) 24 VA, 15 VA Oversized (5 1/4 in. H x 12 1/2 in. W x 2 15/16 in. D) (132 mm x 318 mm x 74 mm) 4-1/ / / / / /16 74 Figure 2: The R (Left) and the R and R (Right) Dimensions (in./mm) 2 R s and ontactors R1000 Series s
3 Application Information ombinations of R1000 products allow for a wide variety of applications; see Figures 3 to 7 for sample configurations. The DPDT relays allow for either normally open or normally closed operation. Note: The R1000 is shipped with a jumper between terminals and 3. In some applications this jumper must be removed, and/or an additional jumper between terminals and must be added. (The, jumper does not come factory installed.) See Figures 3 to 7 for proper jumper positions. Note:! AUTION: If relay contacts 3, 4NO, and 4N need to be isolated from and, then the jumper between and 3 must be removed. Damage to equipment could result if the jumper is not removed when necessary. The R1000 s resistor draws 0.2 amps in all applications. The resistor is used as a load for thermostats with anticipators. (The thermostat would be wired to terminals and.) Hot om Line Voltage ontroller or Thermostat 3 4NO 4N Resistor 5 om 6NO 6N NO To Load ircuit om Hot 3 4NO 4N 120 VA Power to Heating irculator Resistor 5 6NO 6N Storage Tank Aquastat fig3&4 To Storage Tank irculator ircuit Note: The jumper between and 3 is not necessary for this application. Install a jumper between terminals and as shown. Figure 3: Typical Application of the R1000 with Line Voltage ontrolling Action Notes: Install a jumper between and 3 to switch 120 VA. In this application, hot water takes preference over heating. Whenever there is a hot water demand, the heating circulators are automatically turned off. Figure 4: Typical Application of the R1000 with a Hot Water Storage Heater R s and ontactors R1000 Series s 3
4 N o te: In stall a ju m p er between and VA Low Voltage Electromechanical Thermostat Note: Remove the jumper between and VA Three Wire ontrol om 120 V Hot irculator 3 4N O 4N Resistor 5 6N O 6N Burner ontrol om 120 VA Hot Load Input Load Output 3 4NO 4N Resistor 5 6NO 6N fig5& 6 Note: Power is provided to the control via the and terminals. Figure 5: Typical Application of the R1000 with a Gas or Oil Burner ontrol Figure 6: Typical Application of the R1000 when Used with a Three Wire ontrol Low Voltage Thermostat N o. 1 Low Voltage Thermostat N o. 2 Low Voltage Thermostat N o. 3 T T T T R G ZONE 1 ZONE 2 ZONE 3 Multi 120 VA OM OM irculator No. 1 irculator No. 2 irculator No. 3 Figure 7: Typical Application of the R ontrolling Three Zones 4 R s and ontactors R1000 Series s
5 M ounting W iring! AUTION: Read the entire installation sheet before beginning installation. Failure to follow instructions could cause personal injury or property damage. Installation Instructions 1. Gather supplies needed: drill drill bit No. 19 (3.30 mm) two No , (M4, mm) screws if installing the R1000-1; three screws if installing the R or 40 flat-blade screwdriver pliers for knockouts 2. Remove the two cover screws with a flat-blade screwdriver. Pull the R1000 s cover off. 3. Snap out the R1000 circuit board, if necessary. 4. Drill two holes using the mounting holes in the back of the enclosure as a template. 5. Secure the R1000 to the wall using screws and a flat-blade screwdriver. (Replace the circuit board if it was snapped out in Step 3.) 6. Wire the unit as detailed in the Wiring section. 7. Remove the appropriate knockouts with pliers. 8. Replace the cover and the cover screws.! WARNING: Disconnect the power supply before wiring connections are made to prevent electrical shock or possible damage to the equipment. Low voltage wiring connections are made to the screw terminals using AWG wire (18 AWG recommended). For high-voltage wiring, follow the local and applicable National Electric odes. Terminal Designations for the R1000-1, -10, and -20 are detailed in Table 2. With the R , only one common terminal is necessary for the and pair inputs (if used). The rest of the R s terminals correlate with the designations specified in Table 2. Note: All wiring must be in accordance with the National Electric ode as well as local regulations. If the job requires the retrofit of a R with either a Honeywell or a White-Rodgers relay, see Table 3 for terminal designations that correspond with the R1000.! AUTION: If relay contacts 3, 4NO, and 4N need to be isolated from and, then the jumper between and 3 must be removed. Damage to equipment could result if the jumper is not removed when necessary. R s and ontactors R1000 Series s 5
6 ! AUTION: Make all wiring connections and check the connections before applying power to the system. Short-circuited or misconnected wires will permanently damage the unit. Table 2: R1000 Terminal Designations Terminal Name Description 120 VA ommon (Neutral) Input 120 VA Power (Hot) Input 3 ommon of ontacts 4NO and 4N 4NO Normally Open Output of 3 4N Normally losed Output of 3 5 ommon of ontacts 6NO and 6N 6NO Normally Open Output of 5 6N Normally losed Output of 5 24 VA Output Low Voltage Input Low Voltage ommon (for and ) Table 3: ompetitive Wiring ross Reference hart (R1000-1) Product Number Terminal Numbers Replacing Honeywell s with the R R NO 4N 5 6NO 6N G\T RA89A T T R845A T T R RA T T R W B X Replacing White-Rodgers s with the R A T T 829A T T None of the competitive models listed in Table 3 have anticipators. In this application, a jumper between the and terminals of the R must be added. 6 R s and ontactors R1000 Series s
7 Ordering Information The R1000 is not field repairable. To order R1000 units or parts, contact the nearest Johnson ontrols branch office or wholesale distributor, and specify the product code number(s) using Table 4. Table 4: Ordering Information Product ode Number Description R One R board in a standard enclosure R terminal board for R1000-1, R R One R board in an oversized enclosure, with the space to add two more R s R Three relay version of the R in an oversized enclosure, includes a single transformer A100-4 Plug-in replacement relay for any of the above R s and ontactors R1000 Series s 7
8 Specifications Product Power Requirements Output Thermostat Heat Anticipator urrent Draw ontact Ratings Wiring Knockouts UL Listing Ambient Operating onditions Ambient Storage onditions R1000-1, -10, -20, -40 s /60 Hz R1000-1, -10, -20: 5 24 VA (for Each R Used) R : VA 0.2 Amps DPDT ontacts 24 to 120 VA; 1/4 hp at 120 VA; 7.2 Full Load Amps; 43.2 Locked Rotor Amps; 10.0 Resistive Amps Accommodates 1/2 in. onduit Fitting -R1000-1: 3 Knockouts on Top of Enclosure, 3 on Bottom -R , -40: 6 Knockouts on Top of Enclosure, 7 on Bottom (R Only) UL 873 Temperature Indicating and Regulating Equipment F (0-50 ); 10-90% RH, 86 F (30 ) Maximum Dew Point F ( ); 10-90% RH, 86 F (30 ) Maximum Dew Point Dimensions (H x W x D) R1000-1: (5 1/4 in. H x 4 1/4 in. W x 2 15/16 in. D) (133 mm H x 108 mm W x 74 mm D) R and -40: (5 1/4 in. H x 12 1/2 in. W x 2 15/16 in. D) (133 mm H x 318 mm W x 74 mm D) Shipping Weight R1000-1: 1 lb, 13 oz (0.816 kg) R : 12 oz (0.340 kg) R : 3 lb, 6 oz (1.531 kg) R : 4 lb, 5 oz (1.956 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson ontrols office. Johnson ontrols, Inc. shall not be liable for damages resulting from misapplication or misuse of its products ontrols Group FAN E. Michigan Street Master atalog P.O. Box 423 Issue Date 0493 Milwaukee, WI Printed in U.S.A. 8 R s and ontactors R1000 Series s
SEN and SEN Outdoor Air Temperature Sensors
FANs 216, 1628.3 Product/Technical Bulletin SEN-500-2, SEN-500-3 Issue Date 0996 SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors The SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors offer
More informationVA-8020 Floating Valve Actuator
FANs 977, 1628.3 Product/Technical Bulletin VA-8020 Issue Date 0300 VA-8020 Floating Valve Actuator The VA-8020 synchronous motor-driven actuator provides floating (three wire) control of valves with up
More informationA25 Series Warm Air Control with Manual Reset
FANs 125, 121 Product/Technical Bulletin A25 Issue Date 0316 A25 Series Warm Air Control with Manual Reset The A25 Series Warm Air Control with Manual Reset is designed to shut down fans, burners, dampers,
More informationTM-9100 Series Room Command Module
FANs 216, 1628.3 Product/Technical Bulletin TM-9100 Issue Date 0400 TM-9100 Series Room Command Module The TM-9100 Series Room Command Modules are designed for use with the TC-9100 series of DDC (Direct
More informationVA-715x Electric Valve Actuator
Product/Technical Bulletin VA-7150 Issue Date 0513 VA-715x Electric Valve Actuator The VA-715x Series synchronous motor-driven actuator provides incremental (three wire), incremental with feedback, or
More informationEDA-8100 Electric Damper Actuator
Installation Sheet Issue Date 0392 EDA-8100 Electric Damper Actuator Kit Includes 1. EDA-8100-1100 Electric Damper Actuator with counterclockwise spring return, or EDA-8100-1101 Electric Damper Actuator
More informationSeries Y63, Y64, Y65, Y66, and Y69 Transformers
Product/Technical Bulletin Issue Date December 17, 2002 Series Y63, Y, Y65, Y66, and Y69 Transformers The series Y63, Y, Y65, Y66, and Y69 transformers handle 24 power requirements from 40 VA through 300
More informationAV-8020 Series Floating Control Actuated Valve
FANs 977, 1628.3 Product/Technical Bulletin AV-8020 Issue Date 0300 AV-8020 Series Floating Control Actuated Valve The AV-8020 is an electric actuator/brass valve combination that furnishes floating control
More informationM9206-Bxx-2S Series On/Off Electric Spring Return Actuators
Installation Instructions M9206-Bxx-2S Issue Date May 14, 2003 M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation IMPORTANT: Use this M9206-Bxx-2S Series actuator to control equipment
More informationSystem 350 P352AB Electronic Pressure Control Series
System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure
More informationP66 Series Electronic Fan Speed Controls
FANs 125, 121 Pressure Controls Section P Product/Technical Bulletin P66 Issue Date 0498 P66 Series Electronic Fan Speed Controls The P66 is a pressure actuated electronic motor speed controller. This
More informationS-2300 Pneumatic Selector Switch
S-2300 Pneumatic Selector Switch Pneumatic Control Manual 717.1 Selector Switches Section Product Bulletin S-2300 Issue Date 0290 The S-2300 Pneumatic Selector Switch is designed for manual switching of
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationUniversal Packaging Module (UPM)
Metasys Network Sales Resource Manual 635 Network Units Section Product Bulletin Issue Date March 17, 2004 Universal Packaging Module (UPM) The Universal Packaging Modules (UPM) are an expandable enclosure
More informationD24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)
Installation Instructions D24-53 Issue Date November 4, 23 D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m) Installation IMPORTANT: The D24-53 Series actuator is intended to control
More informationM100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications
FANs 268.1, 1628.3 Product Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications The M100Q is a temperature-controlled unit for
More informationQ35 Series Automatic Vent Damper System
Installation Sheets Manual 121 Energy Conservation and Miscellaneous Kits Section Q Technical Bulletin Q35 Issue Date 0999 Q35 Series Automatic Vent Damper System Figure 1: Q35 Automatic Vent Damper System
More informationTE-6300 Series Temperature Sensors
TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued July 14, 2008 Supersedes November 13, 2006 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety
More informationVA-7450 Series. Electric Valve Actuators
34-636- 771, Rev. D Installation Instructions VA-7450 Series Issue Date 0216 VA-7450 Series Electric Valve Actuators Applications VA-7450 Series Electric Valve Actuators provide on/off, floating, or proportional
More informationTE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies
TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies Installation Instructions Part No. 24-4034-42, Rev. D Issued December 9, 2011 Supersedes August 1, 1997 Applications TE-6100
More informationTE-6300 Series Temperature Sensors
TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued April 7, 2010 Supersedes March 13, 2009 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety
More informationM9106-AGx-2N0x Series Electric Non-spring Return Actuators
Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control
More informationP445 Series Electronic Lube Oil Control
FANs 125, 121 s Section P Product/Technical Bulletin P445 Issue Date 0100 P445 Series Electronic Lube Oil The P445 Series Electronic Lube Oil is designed for use on refrigeration compressors equipped with
More informationEP-8000 Series Electro-Pneumatic Transducers
FANs 216, 1628.3 Product/Technical Bulletin Issue Date 1196 eries Electro-Pneumatic Transducers eries Electro-Pneumatic Transducers convert a voltage or current signal from an electronic controller into
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationDamper Actuator Installation
FANs 268.1, 977, 1628.3 Installation Bulletin EPP-1000 Issue Date 0800 EPP-1000 Series Electro-Pneumatic Positioners A pplication The EPP-1000 is designed for applications where electronic control of pneumatic
More informationM9216 Series Electric Spring Return Actuators
*34636461G* 34-636-461, Rev. J Installation Instructions M9216 Issue Date October 217 M9216 Series Electric Spring Return Actuators Installation IMPORTANT: The M9216 Series actuator is intended to control
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationSystem 350 S350P Proportional Plus Integral Temperature Stage Module
FANs 930, 930.5 Add-On Modules Section Product/Technical Bulletin S350P Issue Date 0997 System 350 S350P Proportional Plus Integral Temperature Stage Module The S350P is used in conjunction with the A350
More informationA419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures
Installation Instructions Issue Date April 8, 2008 A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Application IMPORTANT: The A419 Series Electronic Temperature
More informationVA2202-xxx-2 Series Electric Spring Return Valve Actuators
VA222-xxx-2 Series Electric Spring Return Valve Actuators Product Bulletin Code No. LIT-26 Issued March 25, 28 Supersedes March, 26 VA222 Series Spring Return Electric Valve Actuators are available in
More informationP70, P72, and P170 Controls for Low Pressure Applications
Master Catalog 125 Pressure Controls Section P Product/Technical Bulletin Issue Date 0900 P70, P72, and P170 Controls for Low Pressure Applications The P70, P72, and P170 controls for low pressure applications
More informationM9116, M9124, and M9132 Series Electric Non-spring Return Actuators
Product Bulletin M91xxx Issue Date September 2017 M9116, M9124, and M9132 Series Electric Non-spring Return Actuators The M91xx Series includes M9116, M9124, and M9132 models. All of these direct-mount
More informationSeries P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC 0435 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More informationD-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators
Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure
More informationVA-4233-GGx Series Electric Valve Actuators
Installation Instructions Issue Date August 11, 2003 VA-4233-GGx Series Electric Valve Actuators Installation Refer to Figures 2 through 4 for proper actuator orientation before attempting to make the
More informationD-4070 Two Stage Pneumatic Actuator
FANs 268.1, 1628.3 Product/Techncial Bulletin D4070 Issue Date 1095 D-4070 Two Stage Pneumatic Actuator The D-4070 Two Stage Pneumatic Actuator is a multipurpose positioning device used to accurately position
More informationM9210-xxx-3 Electric Spring Return Actuators
M9210-xxx-3 Electric Spring Return Actuators Product Bulletin Code No. LIT-12011056 Issued June 1, 2009 Supersedes February 4, 2009 The M9210-xxx-3 Series Actuators are direct mount, spring return electric
More informationVA-715x Electric Valve Actuator
Product/Technical Bulletin VA-7150 Issue Date March 31, 2014 VA-715x Electric Valve Actuator The VA-715x Series synchronous motor-driven actuator provides incremental (three wire), incremental with feedback,
More informationM9220-xxx-3 Electric Spring Return Actuators
M9220-xxx-3 Electric Spring Return Actuators Product Bulletin Code No. LIT-12011057 Issued September 2017 The M9220-xxx-3 Actuators are direct mount, spring return electric actuators that operate on these
More informationVA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators
FIG:mntpos_H2O_app VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators Installation Instructions Part No. 14-1336-15, Rev. C Issued July 6, 2011 Supersedes December 28, 2007 Applications The
More informationA419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures
A419 Issue Date February 10, 2003 A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures The A419 series controls are single-stage, electronic temperature
More informationM Ball Valve Linkage Kit
Product ulletin M9000-520 Issue Date May 1, 2005 M9000-520 all Valve Linkage Kit The M9000-520 all Valve Linkage Kit is designed specifically for field mounting Johnson ontrols M9106 and M9109 Series Non-Spring
More informationVA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators
VA9104-xGA-1S ii01.cdr VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators Installation Instructions Part No. 14-1336-7, Rev. B Issued December 28, 2007 Supersedes April 12, 2006 Applications
More informationG76x Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition
More informationSeries P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC9733 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More informationATP-2040 Electric Damper Actuator/Transmitter
ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential
More informationVA-720x Electric Valve Actuator
34-636-496,Rev.FProduct/Technical Bulletin VA-7200 Issue Date 0216 VA-720x Electric Valve Actuator The VA-720x Series synchronous motor-driven actuator provides incremental (three wire), incremental with
More informationM9300 Series Electric Non-Spring Return Actuators
M9300 Series Electric Non-Spring Return Actuators Product Bulletin M9308-AGA-2Z, M9308-AUA-2Z, M9310-AUA-2, M9310-HGA-2, M9320-AUA-2, M9320-HGA-2, M9335-AUA-2, M9335-HGA-2 The M9300 Series Electric Non-Spring
More informationM9109 Series Electric Non-spring Return Actuators
34-636- 1190, Rev. D Installation Instructions M9109 Issue Date 03/1/16 M9109 Series Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109 Series actuator only to control equipment
More informationVA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design
VA-7150 Electric Valve Actuator European Electronic Controls Catalogue Section E Product Bulletin VA-7150 Issue Date 03 2000 I ntroduction The VA-7150 series synchronous motor driven actuator provides
More informationA419ABG-3C Electronic Temperature Control
Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where
More informationP10 Series Low Range Pressure Controls
Master Catalog 125 Pressure Controls Section P Product Bulletin P10 Issue Date 1290 P10 Series Low Range Pressure Controls Application The P10 Series low pressure controls are for applications in which
More informationRD-2000 Round Control Dampers
RD-000 Round Control Dampers Product Bulletin Code No. LIT-8105 Issued February 5, 010 Supersedes July, 009 Johnson Controls provides top-quality, low-leakage RD-000 Round Control Dampers for use in Heating,
More informationG72x Series Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition
More informationM x Series Valve Linkage Kits
Installation Instructions M9000-51x Issue Date 05/01/02 M9000-51x Series Valve Linkage Kits Installation Parts Included Quantity Description 1* Actuator Mounting Bracket 1* Adjustable Anti-Rotation Slider
More informationM9203-xxx-2(Z) Series Electric Spring Return Actuators
M9203-AGx-2(Z), M9203-GGx-2(Z), M9203-Bxx-2(Z) M9203-xxx-2(Z) Series Electric Spring Return Actuators Code No. LIT-1900682 Issued February 16, 2011 Description The M9203-xxx-2(Z) Series Electric Spring
More informationSeries P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)
PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression
More informationVSD Series II Variable Speed Micro Drives
VSD Series II Variable Speed Micro Drives Product Bulletin Code No. LIT-12011813 Issued March 26, 2013 Refer to the QuickLIT website for the most up-to-date version of this document. Johnson Controls VSD
More informationSeries P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits
PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty Introduction The P100 Series are
More informationM100F Incremental Motor Actuator R81F Interface Board
Installation Sheets Manual 121 Motor Actuators Section M Technical Bulletin M100F Issue Date 0493 M100F Incremental Motor Actuator R81F Interface Board Application Details Figure 1: M100 Motor Actuator
More informationF61 Series Standard Flow Switches
Installation Instructions F61 Issue Date July 30, 2002 F61 Series Standard Switches Installation IMPORTNT: ll F61 Series Switches are intended to control equipment under normal operating conditions. Where
More informationG861 Series Integrated Function. Direct Spark Ignition Control
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G861 Issue Date 0699 G861 Series Integrated Function Direct Spark Ignition Control Figure 1:
More informationPC-125x Counter-Balanced Backdraft Damper
PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls
More informationM9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators
34-636- 1484, Rev. B Installation Instructions M9109-GGx-4 Issue Date March 2016 M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators Installation IMPORTANT: The M9109-GGx-4 Series Electric
More informationM9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators
M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators 34-636- 1468, Rev. B Installation Instructions M9106-GGx-4 Issue Date March 2016 Installation IMPORTANT: The M9106-GGx-4 Electric Actuator
More informationF261 Series Fluid Flow Switches
F261 Series Fluid Switches Product Bulletin Code No. LIT-12011987 Issued March 9, 2015 The F261 Series Switches respond to fluid flow in lines carrying water, ethylene glycol, or other nonhazardous fluids.
More informationY75 Series Sensing Probes
Product Bulletin Y75 Issue Date August 22, 2008 Y75 Series Sensing Probes The Y75 Series Sensing Probes are used with Direct Spark Ignition (DSI), Hot Surface Ignition (HSI), and Intermittent Pilot Ignition
More informationM9000-3xx Series Weather Shield Enclosures
M9000-3xx Series Weather Shield Enclosures Product Bulletin Code No. LIT-1201704 Issued June 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The M9000-3xx Weather Shield
More information- Wiring Brochure tekmarnet 4 Thermostat 545
- Wiring Brochure tekmarnet 4 545 W 545 12/08 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Layout Brochure ough-in 4 Wiring Brochure
More informationM9106-xGx-2 Series Electric Non-Spring Return Actuators
34-636- 1085, Rev. E Installation Instructions M9106-xGx-2 Issue Date March 2016 M9106-xGx-2 Series Electric Non-Spring Return Actuators Installation IMPORTANT: Use this M9106-xGx-2 Series actuator only
More informationTE-6001 Hardware Assemblies for TE-6000 Temperature Elements
*24403434E* 24-4034-34, Rev. E Product/Technical Bulletin TE-6001 Issue Date September 2017 TE-6001 Hardware Assemblies for TE-6000 Temperature Elements TE-6001-2 TE-6001 Hardware Assemblies are used with
More informationP20, P21 Series Air Conditioning Limit Controls
Master Catalog 125 Pressure Controls Section P Product Bulletin P20, P21 Issue Date 0318 P20, P21 Series Air Conditioning Limit Controls Application These air conditioning limit controls are specially
More informationP70, P72 and P170 Series Controls for High Pressure Applications
Installation Instructions P70 Issue Date October 16, 2002 P70, P72 and P170 Series Controls for High Pressure Applications Application P70, P72 and P170 Series Controls for High Pressure Applications provide
More informationMetasys Zoning Package
Product Bulletin Issue Date August 26, 2002 Metasys Zoning Package Building Automation System The Metasys Zoning Package improves occupant comfort by providing reliable zoning control of standard packaged
More informationM9300 Series Switch Kits
M9300 Series Switch Kits Installation Instructions M9300-1, M9300-2 34-636- 2472, Rev. C (barcode for factory use only) Part No. 34-636-2472, Rev. C Issued June 2017 Application Requirements Refer to the
More informationA11 Series Low Temperature Cutout Control
A11 Series Low Temperature Cutout Control Installation Instructions Part No. 997-358, Rev. F Issued March 2016 Applications IMPORTANT: All Series A11 temperature controls are designed for use only as operating
More informationCommerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller
LC-ZEC200-xxxx Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller Description The CCS Variable Air Volume (VAV) Zone Pressure Independent Damper Controllers
More informationM9208-xxx-x Series Electric Spring Return Actuators
M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin M9208-GGx-x, M9208-AGx-x, M9208-Bxx-3 The M9208-xxx-x Series Electric Spring Return Actuators provide control of dampers in Heating,
More informationVC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS
ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES INSTALLATION INSTRUCTIONS Power consumption: 6 Watts Max. at nominal Voltage (during valve position change). Use 24 V Class 2 transformer and provide
More informationMODEL SMZ-SW ZONE CONTROL SYSTEM
DuroZone MODEL SMZ-SW ZONE ONTROL SYSTEM DuroZone is a division of orporation PART# 35226 PART# 35227 SMZ-2SW/SMZ-3SW INSTALLATION INSTRUTIONS ongratulations on purchasing a DuroZone SMZ ontrol System.
More informationSD-1250 and SD-1600 Series Smoke Dampers
SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke
More informationIntroduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits
PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100 Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty.
More informationVG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves
Product ulletin VG000 Issue ate 11/01/01 VG000 Series High-apacity/High-loseoff Electric Zone Valves VG000 Series High-apacity/High-loseoff Electric Zone Valves are designed to regulate the flow of water
More informationMetal Enclosure. Application Note: Metal Enclosure Page 3
Metasys Network Technical Manual 636 App. Notes: Network Units Section Technical Bulletin Issue Date 0793 Metal Enclosure Application Note: Metal Enclosure Page 3 Introduction 3 What You ll Need 3 Thermal
More informationVG2000 Series Cast Iron Flanged Globe Valves
Installation Instructions VG2000 Issue ate November 15, 2002 VG2000 Series ast Iron Flanged Globe Valves pplication VG2000 Series ast Iron Flanged Globe Valves are primarily designed to regulate the flow
More informationFlare Valves 1/2 inch 2-Way and 3-Way
Valve and Actuator Manual 977 Valve Product Information Section Product Bulletin VTF Series Issue Date 0596 Flare Valves 1/2 inch 2-Way and 3-Way The 1/2 inch flared valve line is designed to accurately
More informationAdjustable Torque Controls
MCS0 Adjustable Torque Control The MCS0 is an enclosed control complete with a cover and mounting provisions. A brake and clutch may be operated separately with this control or up to four units, two at
More informationCAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*
CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,
More informationG821L/G822L Series Integrated Function Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G821L/G822L Issue Date 1199 G821L/G822L Series Integrated Function Direct Spark Ignition Controls
More informationBarbara, Here is the list of items. I numbered the attachments to match with the numbers below.
From: Dan Wilson [mailto: DWilson@wilsonengineerinciservices.com] Sent: Thursday, April 09, 2015 5:10 PM To: Bernstein, Barbara Subject: RE: checking... Barbara, Here is the list of items. I numbered the
More informationR820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017
R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating
More informationM9109-GGx-5 Series Proportional Electric Non-spring Return Actuators
34-636- 1360, Rev. C Installation Instructions M9109-GGx-5 Issue Date March 2016 M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109-GGx-5 Series
More informationM9206-GGx-2S Series Proportional Electric Spring Return Actuators
Installation Instructions M9206-GGx-2S Issue Date November 17, 2004 M9206-GGx-2S Series Proportional Electric Spring Return ctuators pplications The M9206-GGx-2S Series Proportional ctuators are direct-mount,
More informationG600 Series Replacement Intermittent Pilot Ignition Controls
Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
More informationRA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System
RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System Product Bulletin Code No. LIT-12011620 Issued July 2, 2014 RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow Measuring System averages
More informationInstallation Instructions
MotorMaster ontrol Kit for Residential Split System Applications ancels: IIK 561-18-1 IIK 561-18-2 9-97 Installation Instructions Part No. 32LT660004 and 005 NOTE: Read the entire instruction manual before
More informationM9208-Bxx-3 Series On/Off Electric Spring Return Actuators
M9208-Bxx-3 Series On/Off Electric Spring Return Actuators Installation Instructions M9208-BAA-3, M9208-BAC-3, M9208-BDA-3, M9208-BDC-3, M9208-BGA-3, M9208-BGC-3 Part No. 34-636-2103, Rev. B Issued May
More informationInstallation Instructions
PLOWAMB001A00 SMALL ROOFTOP UNITS GAS HEAT/ELETRI OOLING, ELETRI OOLING AND HEAT PUMP UNITS AESSORY MOTORMASTERR II HEAD PRESSURE ONTROLLER 60Hz 3to12---1/2tons Installation Instructions IMPORTANT: Read
More informationCSD Series Current Devices Split Core
CSD Series Current Devices Split Core Installation Instructions CSD-CF0A0-1 CSD-CF0J0-1 CSD-CA1G0-1 Part. 24-10345-34, Rev. D Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch
More information